GE Power Electronics BLST-SP77X Electric Discharge Lamp Control Equipment User Manual X82 BLST SP77X Rev1

GE Power Electronics (Shanghai) Co., Ltd. Electric Discharge Lamp Control Equipment X82 BLST SP77X Rev1

Contents

X82-BLST-SP77X_User Manual_Rev1

Electronic Ballast For Electrodeless Fluorescent Lamp
1Product code.
150W SP779#
200W SP780#
Note: # means the model designation may be followed by suffix.
2Outside characteristic.
The outside picture of Electronic Ballast For Electrodeless Fluorescent Lamp as below,
there are three wires at input port, L line is blueN line is gray, GND line is yellow and green.
There are two white wires at output port. The input wires connect to the power grid, and the
output wires connect to the Electrodeless Fluorescent Lamp.
Outside picture
Inside picture
Size
Size picture
3Electrical characteristic.
1) Input Voltage: 90-150Vac
2Input Rating Current
1.5A @120V--electrodeless lamp 150W
1.9A @120V--electrodeless lamp 200W
3Output Rating Current
0.81A (load,electrodeless lamp 150W)
0.96A (load,electrodeless lamp 200W)
4Output Rating Voltage
190V (load,electrodeless lamp 150W)
210V (load,electrodeless lamp 200W)
5Start Trigger Voltage
2000±100Vop (load,electrodeless lamp 150W)
2350±100Vop (load,electrodeless lamp 200W)
6Output Frequency
230K±30kHz(load,electrodeless lamp 150W)
230K±30kHz(load,electrodeless lamp 200W)
7Open circuit and short circuit protection
4Ambient temperature.
Generally the ballast is set up in the lamps and lanterns to use, the ambient temperature of
ballast is -40--60in lamps and lanterns.
FCC STATEMENT:
This light device has been tested and found to comply with the limits for Consumer
RF Lighting device, pursuant to Part 18 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
This product may cause interference to radio equipment and should not be installed
near maritime safety communications equipment or other critical navigation or
communication equipment operating between 0.45 – 30MHz.

Navigation menu