GE Reverse Osmosis Manual L0502438
User Manual: GE GE Reverse osmosis Manual GE Reverse osmosis Owner's Manual, GE Reverse osmosis installation guides
Open the PDF directly: View PDF .
Page Count: 84
Download | |
Open PDF In Browser | View PDF |
www.GEAppliances.com Safety Instructions Safi:ty Instructions .............. Specification Guidelines ......... Operating Instructions About the RO System 2 g ......... 4, 5 Tools and Materials Required Before Beginning Installation Mounting System Installation Feed Water Supply ........... Faucet Assembly ............ Battery Installation ............ Filtration Drain Connection ..... 6 . . .6, 7 ..... 8 9-12 13, 14 14 . .15, 16 Installation Storage PXRQ I SF PNRQ15FBL Instructions Tank and Startup ....... Syst_me de Filtration La section fran_aise commence a la page 27 Osmosis Inversa RO Camidge Replacement Sanitization .................. Water Test Kit ................ Tips Inversde 17 Care and Cleaning Prefitte_; Postfiher and Troubleshooting Osmose ...... ...... 18 19 20 Sistema de Filtraci6n 21, 22 La secci6n en espafiol empieza en la pkgina 55 ¢) Consumer Support Consumer Support ..... Parts List/Catalog .......... Warranty .................... Back Cover 24, 25 26 Tested and Certified by NSF International to NSF/ANSI Standard 5& See Performance Data Sheet for the reduction of the claims specified on the Performance Data Sheet. > Essay_ et certifi_ par NSF International conform_ment aux normes 58 NSF/ANSI. Consuttez ta feuille de donn_es de rendement pour la r_duction des caract_ristiques indiqu_es sur la feuille de donn_es de rendement, Probado y certificado pot NSF International por cumplir con el est_ndar 58. Vet la hoja de datos de desempefio para Ia reducci6n de reclamos especificados en la hoja de datos de desempefio, Write the model and serial numbers here: Model # Serial # You can find _eIn on the bracket. 101019-A 215Cl174P002 49-50144 11-04JR IMPORTANT SAFETYINFORMAtiON. READ ALL INSTRUCtiONS BEFOREUSING. the information in this manual must be followed to minimize the risk of A WARNING! Forroyouresafe_ damagoor ersonalinju .i SAFETYPRECAUTIONS m Check wifll your state aim local public works deparunent for phnnbing and _nilation codes. You must follow these guidelines as you install fl:e Reverse Osmosis system. Usinga qualifiedinstaller is recommended. • Ifhouse water pres_sure is over the maximum (1_'0poumts per s(p_re inclO, install a pressure reducing valve in dm water supply line to the Reverse Osmosis system. • Be sure tile water supply confi,)rms with Ihe SpecificationGuidelines.ff the water supply conditiolls are uIlk!lowIl, COZllaCt your muIlicipal *_,ater comKomy or your local bealfl: department ff)r a list of coI_laminaI_tSin your area and a list of lalx)ratories certified by your slate to analyze drinking waten it WARNING'. Before ruing dm Reverse Osmosis system fbr the first time, tile system must be purged. The Reverse Osmosis cartridge contains a fbod grade preservative that tmtst be purged from the system. The preservative will give product water an unpleasant taste and eden Do :lot use with water that is microbiologically unsafe or of unknown quafi/y ltLWARNING'. without adequate disinfection befbre or after the system. SDtems certified fi)r cyst reduction may be used on disinfected water dial may contain fiherable cysts. This system has been tested ff)r the treatment of water conlaiuing pentavalent aeueIfiC (alto talowI: a_sz_s(V), As(+5) or ar_Ilate) at concentra(lOIlS of 0.050 mg/L or less. Tiffs sysmm re&rues peIwavalent arm:tic, but ::lay :lot remove otimr fi_nns of arsenic. "I]lis system is to be/tsed oil water supplies containing a detectable free dflorine residual or on water supplies that have been deInonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sttitlcient to ensure complete COIlversion of trivalent _IfiC to penlavaleI:t arseItiC. Please see the _IfiC Facts section of the Perfbrmance Data Sheet fbr fi_rther infi)rmafion. This Rever_ OsInosis system contains a replaceable treaunent Inembrane ca_ridge critical far effecfive re&mtlon of'Ibtal Dissolved Solids. The water should be tested pefiocrmally to verify thai tile system is perfbmfing mtist_t(Mly. PROPERINSTALLATION AND MAINTENANCE This Reverse Osmosis system must be properly installed and located in accordance with the Installation Instructions before it is used. • Install or store wbere it will not be expend to • If Rever_ Osmosis system is connected to a tempeI_atures below fi'eezing or exposed to any type refrigerator icemaker, a special icemaker of wealher. Water freezing in the system will coIllleetioI1 kit is required (RV!ZAT).Do Dot use damage il. Do Dot attempt to treat water over 100°E copper robing ff)r file COIlIlectio[l between the • Do :lot install Oil HOTWATER.The temperature Reverse Osmosis system aim tile refrigerator. ofthe water supply to tile Reverse Osmosis system A [/VA_NING: Discard all um_xt pans mad packaging UlUStbe between the lililtiinuin of 40°F and the material after il?_sPallation. Small _s remaining after Illax'unuin of I(X)°E See tile Specification Guideline& tile immllallon couM be a choke ha2"ard. • Extended non-use of the Reverse Osmosis system. If tile sDtem has not been used fbr one week or more, open tile RO water t_aucetand allow tile system to drain. Close tile RO water fsucet aud allow tile s_tem to regenerate the water supply. • RecomIneuded installation is under the sink. However, tile unit can be installed in a remote location, up to 20 feet away fi_om tile sinlc • However, adcFHional materials will be required. See Ira,s list to obtain addifional materials from GE. • Locating the rank on a l_asement floor, witil the faucet at a first floor sink may result in some loss of flow rate laid capacily (approzdmately 20%). Installing a second tank will iInprove tiffs perfi_rmance. _Jl RVK1T can be umd. • Smfitize upon installation of dm Reverse Osmosis system and after servicing iImer parts, inchlding replacement of prefilter, postfilter and Reverse Osmosis carteidge. It ksimpormalt to have clean bands wlfile haI_dling iImer parts of tile system. See dm Sanitizingthe Reverse OsmosisSystem section. • This Reverse Osmosis system contains a replaceable treatment component critical fbr ef[:ccfive reduction of total dis_solvedsolids. This product water shall be tested periodically to verify that tim system is performing satisfactorily. See tim About the Water TestKitsection. BE SURE TO FOLLOWALLAPPLICABLESTATE AND LOCALCODES. READAND FOLLOWTHISSAFETYINFORMATIONCAREFULLY. SAVETHESEINSTRUCtiONS 2 Specificationguidelines. .GE4ppliancns.oom Product- height11" width 10.5" depth4" system Illakes a good supply of drinking waler each d_y. How much itwill make depends primarily on these things... Ttle Feed water pressure limilsipounds per square inch (psi) ...................... Feed water temperature limitsiminimum/maximum Maximum Total Dissolved Solids (TDS)ipatts 40-120, degrees F ................. 40-100 per million (ppm) ................ 2000 Maximum water hardness @ 6.9 pH recommended to optimize membrane lifelgrains per gallon (gpg) ................................................. 10 8 7.5 ForwatorwithhardnossgreaterthanlOgrains(at6.gpH),theuseofa softener is recommended. Failure to install a water softener will reduce the life of the Reverse Osmosis membrane. See chart for additional information on the possible need for a water softene_ _ 7 _ __ 'f_ _3_ENE}{ 30 48 _E_MNEN#EO 6 ,Wn o{er_eqS°u_ t r 10 20 #l_OM#lt_ WATER_I_DN_SS 50 Maximum iron, manganese, hydrogen sulfide (ppm) ...................... <6.1 Chlorine in water supply ............................................. ZO ppm Maximum Agowab/e b Feed water pH limits (pH) ............................................ 4-10 Storage tank capacity--gallons 4_ ....................................... Automatic shutoff control ............................................ yes Prefilter and pnsffilter (FQROPF) Carbon Block ............................................... Reverse Osmosis membrane ......................................... (FQROMF) Thin Film Po/yamide Storage Tank Dimension (inches) ...................................... height 15" diameter 1I" System Body Dimension (inches) ...................................... height 11" width 10.5" depth 4" a. If house water pressure is over ] 20 psi, install a pressure is under 40 psi, install a Reverse Osmosis booster pump reducing _-alve in the water supply line. ]i house _-ater pressure (contact your local plumbing supply company). b. Removed (maximum ot 2.0 ppm)by the Reverse Osmosis prefilter. destroy the Reverse Osiylosis iIlelllbr3lle. c. Theoretical 2.3 gMlons. tmtk capacity. When tested according 8[_ (t_p_) to NSF/ANSI REGULAR MAINTENANCE IS REQUIRED.Chlorine Standard 58 at 50 psig inlet pressure, tank capacity will is 3 About the reverse osmosissystem. How the Reverse OsmosisSystem Works Reverse Osmosis reduces Tolal Dissolved Solids (TDS) and organic matter from waler by diffilsing it through a special inembrane. Tile meinbrane separates nfinerals and impurities froin tile x_rater and dmy are flushed to lhe drain. High quality product water goes directly to tim drinking water fbucet or to 1he storage tank. The system ulakes a good supply of drinking water each day. How lnuch it maJxes depends on the feed water supply pressure, temperature and quality. The prefilter and postfiher are replaceable cartridges. The carbon prefiher reduces chlorine while also filtering sediments. The postfiher reduces any other undesirable tastes and odors before you use the x_-aten The system includes an eleclronic fiumet a._sembly *dth a prefiher and posltilter change reminden When six months have pa._sed, a flashing blue light *rill remind you to change 1he n_,ofilters. Description of the Reverse Osmosis System _Pl_filter--Water from the cold supply pipe is directed m the prefiher cartridge. The prefilter is a replaceable rudiment cartridge containing activated cartxm. The prefiher re(hlces chk)rine in the t:ce(l water because CHLORINEDESTROYSTHE REVERSEOSMOSIS MEMBRANE Filtered, clem_, chlorine-reduced _vtter flo_ from lhe prefilter to tim Reverse. (_mosis cartridge. _Reverse OsmosisCartridge--The middle cartridge includes a tightly wound, special membrane. Water is fbrced through tile cartridge where the membrane reduces the dissolved solids and org_aaficmatron High quality product water exits lhe Re_/erse Osmosis caru'idge and goes Iv)the storage tank. Reject water, with tim dissolved _)lids and organic malter, leaves the cartridge and is discharged m the drain throu[01 1/4" tubing. _]Postfilter--After leaving tile storage area, but before going to the system tZaucel, product waler goes Io lhe postfilter carlridge. The postfiher is also a replaceable sediment cartridge that conlains activated carbon. Any remaining tastes, odors or sedilnenls are reduced from product waler by the postfiher. Clean, high quality drinking water flows through the robing and to lhe systeul faucet. _Storage Tank--The storage area holds up m 2-1/2 gallons of product waler. A diaphragm inside lhe lank keeps water pressurized, when Ihe tank is fifll, for fkst flow to the faucet when drinking water is needed. 4 www.GEAppliances.com _tCheck Valve---The check valve prevents cause tile Reverse Osmosis membI_ane a backward I(o nlplure. flow of product water from tile storage tank. A backward flow could _Automatic ShutoffAssembly--To coilserve water, tile drinking *_ater system has aI1 automatic shutofE When the smr'age milk ha_sfilled to capacity and the drinking water t:aucet ksclosed, pressure closes the shutofE Water flow to the Reverse Osmosis housing is shut off until drinking x_ater is used again, and pressure drops in the Reverse Osmosis system. F_FIow CotltroI--The flow control regulates the flow of water through the Reverse (Nmosis cartridge produce high quality water. The control is located in the 1/4" drain line exiting off' the manif_.)Id. at the required rate to _Faucet and Electronics--The countertop [_tucel dispenses fillered drinking water when opened. It ha_sa hand-operated lever, with wariable flow adjusunent. You can keep the f_ucet open by removing your hand fi*om the lever once water is flowing. "Ii_ comply with phunbing codes, an air gap is built into lhe f_ucet drain water connection. The electronic faucet prox4des a six month timer to reInind you when it is time tO replace your prefilter mid postfilter. Replace the filters when the blue light begins to flash in order to protect the RO membrane and keep tile systeIn fimctioning properly. 5 Installation Instructions I Questions? Call 800.GE.CARES WARNING: personal injury Reverse Osmosis Filtration System Models (800.432.2737) Read entire or property manual. or Visit our Website Failure to follow PXRQ15F and PNRQ15FBL all guides and rules could cause damage. • Check with your state and/or local public works department for plumbing follow their guides as you install the Water Filtration system. NOTE: Failure to comply with these installation the installer will be responsible for any service, BEFORE BEGINNING Read these instructions and carefully. • Electric drill and 1-1/4" Drill Bit (type as required) if mounting is needed for faucet • 1/16" Drill instructions for pilot holes) governing • Phillips and Flat Blade Screwdrivers • If your main water line is a rigid pipe, you will require a compression fitting and possibly other plumbing hardware to complete the installation. • Product failure is not covered • A shutoff • Product Literature (Owner's Installation Instructions) • Performance • Feed Water • Drain Manual and Supply • Faucet Assembly with Monitor and Tubing • Storage and Tubing and Data Sheet Adapter Electronic use. Valve Base Tank Line Adapter 6 is the responsibility due to improper installation under the Warranty. valve must near the installation CONTENTS INCLUDED WITH PRODUCT Assembly inspector's codes and ordinances. • Proper installation of the installer. nTnr_Rn Osmosis for local • Note to Consumer - Keep these instructions for future reference. J-L_/'_UIIUI_I." TO avoid damaging the sink, consult a qualified plumber or installer for drilling procedures. Special drill bits may be needed for porcelain or stainless steel. • Reverse completely • Note to Installer - Be sure to leave these instructions with the Consumer. Knife A _^| INSTALLATION • IMPORTANT - Observe a, • Tape Measure • Utility and • IMPORTANT - Save these Wrenches Bit (optional codes. You must instructions will void the product warranty, repair or damages caused thereby. TOOLS AND MATERIALS REQUIRED FOR INSTALLATION • Two (2) Adjustable I at: www.GEAppliances.com be available point. or added Installation Instructions Things to Check Before Beginning RO product 318" drain tube water Installation faucet mounted j 3/8" outlet through sink or countertop (black) T, Disposer Feed water ada (yellow tube (blue banded) banded) T 15" 3/8"storage tank tube (red banded) TUBING/FILTER Prefilter FILTRATION DRAIN CONNECTION DETAIL Postfilter Membrane A suitable drain point and air gap (check your state and/or local codes) are needed for reject water from the Reverse Osmosis membrane cartridge. 1/4" yellow banded inlet 1/4" black tube to 3/8" red banded tube 3/8" blue banded from supply valve faucet to storage tank tube to faucet RO FAUCET The RO product water faucet installs on the sink or on the countertop next to the sink. Often, it is installed in an existing sink spray attachment hole or a hole may be drilled. Space is required underneath for tubing to and from the faucet, and for securing the faucet in place. All faucet connections are done on or above the sink or countertop. FEED WATER The water supply to the undercounter Reverse Osmosis system must have the qualities listed in the specifications. Municipal water supplies most often will have these qualities. Well water may need conditioning--have the water tested by a water analysis laboratory and get their recommendations for treatment. A ,,,A, BASEMENT If installing in a basement, leave enough tubing in place during installation to be able to move unit to floor for ease at servicing and making filter/membrane changes. Additional tubing and fittings required. ,T,/_R, m-lt.r/"&U/IUl_l," For water with INSTALLATION a hardness greater than 10 grains (at 6.9 pH), the use of a softener is recommended. Failure to install a softener will reduce the life of the Reverse Osmosis cartridge. NOTE: See parts list on page 25 for optional parts that may be required for a basement installation. 7 Installation Instructions REVERSE OSMOSIS ASSEMBLY MOUNTING SYSTEM INSTALLATION . Choose a location under the sink to mount the system. Location should be easily accessible, with adequate clearance between the bottom of the filter cartridges and the floor or bottom of the cabinet for removal of filter cartridges. Allow enough space on either side of the system for the tubing con nections. 1. Remove the prefilter cartridges. Hold the Reverse Osmosis the wall surface where you it. Mark location for screws. be a minimum of 17 inches marks to the bottom of the and postfilter Screw assembly up to wish to install There should from the cabinet floor. locations A,-, ,,, ,-,-,,-,R, AuLI_,/-_U/IUI_I'DO not get dirt or debris inside the assembly area. Use only to mark mounting hole locations. Toremove Prefilter _, U_Toremove "_-'_"U U_l_ Remove the assembly cover by unlocking the four tabs on the cover from the system. 3. Use a flat-head screwdriver to work from left to right from the underside of the system. 4. Install screws to the wall, leaving a 3/16inch clearance between the head of the screw and wall (drill pilot holes if needed). 7. Hang the Reverse Osmosis assembly on the screws. Tighten or loosen the screws as desired until the system is secure on the wall. 8. To install the cover, line up the front tabs on the cover with the openings in the system. • Postfilter 2. Screwdriver 6. positioning Use the icons on the bottom of the system for screwdriver positioning. ,Tab 9. Screwdriver Snap the in place; tabs will allowing cover to in place. 10. Remove 8 membrane cartridge. J cover the flex, the snap the To remove Membran_ Installation Instructions FEED WATER SUPPLY Check and comply with local plumbing codes as you plan, then install a cold feed water A. PREFERRED INSTALLATION Utilizing existing kitchen valve (A) and removable 1. . 3. 4. Assemble adapter (C) and coupling (D) as shown in illustration at left, per your configuration. Ensure that the gasket (G) is in place before final assembly. Start installation by hand, then finish tightening with adjustable wrench. Be careful not to overtighten or cross thread as damage to threads may occur. 5. Hand tighten assembled adapter (C) onto supply valve (A) for the proper size installation. Be sure gasket (G) is in place before final assembly. Start installation by hand, then finish tightening with an adjustable wrench. Be careful not to overtighten or cross thread as damage to threads may occur. 6. Reconnect of adapter sink water supply faucet tubing (B). Refer to illustration below to complete assembly depending on supply valve size (A). Close the cold water under the sink. supply valve (A) Unscrew the flexible tubing line (B) from the supply valve (A) that connects to the COLD water riser. NOTE: For rigid pipe, see C. Optional Installation on page 10. Note Adapter (C) orientation: 3/8-inch installation--Rounded (C) connects to supply valve end of adapter (A). (B) Faucet F_ tubing line (not _< \ . ,C} \ Adapter 'F)[_nlet v_ _ (S} Faucet _r .... tubing _) valve (not included) Cut wire ties on tubing coils, using care not to damage tubes or parts if using a utility knife. 8. Remove the 1/2" nut (I) and ferrule (H) from end of inlet valve. Using the yellow banded tubing provided, place the nut (I) and ferrule (H) onto the tubing and install onto inlet valve (F) as shown at left. Tighten with adjustable wrench. Be careful not to overtighten or cross thread as damage to threads may occur. NOTE: Inspect the ends of the tubing prior to installation to be sure there are no imperfections and that the end of the tubing is cut square. It may be necessary to cut the tubing again. Gasket \ (A) Cold water supply valve (not line (B) to top fine (A) Cold water supply tubing 7. For 1/2" Plumbing _ faucet (C). NOTE: If inlet valve (F) is to be removed for installation, refer to E. Removal and Reinstallation of Inlet Valve on page 11. 1/2-inch installation--Rounded end of adapter (C) connects to coupling (D), then to existing faucet tubing (B). For 318" Plumbing supply fitting. included) 9 Installation Instructions FEED WATER SUPPLY (cont,) B. OPTIONAL HOME INSTALLATION Where codes permit (Requires additional C. OPTIONAL RIGID PIPE INSTALLATION parts) *For 1/2" OD or larger metal tubing only. For installation with rigid pipe between valve and sink faucet. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts. Option Saddle valve is available through GE Parts and Services at 1.800.626.2002, part number WS15X10023. Self piercing saddle valves are not recommended. 1. DANGER: Many homes . Close the water supply the handle clockwise. valve are *For 1/2" gasket supply connection OD or larger (using saddle valve)* metal tubing only, Pre-drill Nut (2)--not 1/4" required in clamp if holes are threaded "_[_. hole Seal--make pipe from Obtain flexible plumbing. 3. Install 4. GO back to A. Preferred flexible supply valve and sink pipe sized to your pipe. Installation step 4. 2 1. Obtain pipe. compression 2. Obtain any other fittings required to connect compression fittings to adapter. fittings 3. Remove pipe from 4. Cut pipe to fit length and adapter. 5. Install 6. GO back to A. Preferred compression section, Some threads should be water 2. by turning • Snug valve into bracket (DO NOT OVERTIGHTEN) Optional Remove faucet. to fit rigid NOTE: Adapter has 1/2-inch and 3/8-inch internal and external threads. Open the main water supply valve and several house faucets to purge air from the system. Close faucets when water runs smoothly. Rubber 1. Option electrically grounded through the plumbing. To protect yourself from serious injury or fatal shock, use a battery-powered hand drill only to make the hole. DO NOT USE AN ELECTRIC DRILL. 2. 1 section, Turn off the cold water supply and attach saddle valve as required by product selection. (Be sure to follow manufacturers' Installation Instructions). supply sure the seal is in place Claml Handle Jse to connect the tubing nut 10 supply valve. of assembled fitting fittings to pipe. Installation step 4. NOTE: Above described included the product. with materials are not Installation D. OPTIONAL REMOTE INSTALLATION (requires 1. . . 4. Turn offthe additional Instructions LOCATION E. REMOVAL AND RE-INSTALLATION OF INLET VALVE (requiredonly if inlet valve part) cold water complete supply. 1. Complying with plumbing codes, install a fitting on the cold water pipe to adapt 1/4" OD tubing. A typical connection is shown in illustration below. Make sure a water supply valve is used. pipe "J Z._ , Water supply valve Insert (not included) I14" (yellow banded) tubing to inlet (F)Inlet valve _j Remove all sealing tape from (F) and adapter (C) threads. inlet valve 3. Hand tighten assembled adapter (C) onto supply valve (A) for the proper size installation. Be sure the gaskets (G), as shown on page 13, are in place before final assembly. Finish tightening with adjustable wrench. Be careful not to overtighten or cross thread as damage to threads may occur. 4, Using white thread sealing tape provided, apply approximately 9 wraps of tape around the large threads on inlet valve (F) in a clockwise direction, as shown below. Ferrule I_ 13) "d"W/// Preferred water supply connection (using compression fitting) Cold water 5 on page (Cl If the RO unit is to be installed more than 6 feet from the faucet, replace the blue banded outlet tubing with a longer length of GE 3/8" tubing. A 33 foot length is available through GE Parts and Services at 1.800.626.2002, part number WS07X10019. See Faucet Installation on page 13 for more details. DO NOT SUBSTITUTE TUBING OF UNKNOWN QUALITY. _/_ Step to Remove inlet valve (F) from adapter (C) using adjustable wrench on valve body. See illustration below for detail. DO NOT USE WRENCH ON HEX NUT END OF VALVE AS LEAK MAY OCCUR. If the RO unit is to be installed more than 6 feet from the valve, replace the yellow banded inlet tubing with a longer length of GE 1/4"tubing. A 33 foot length of 1/4" tubing is available through GE Parts and Services at 1.800.626.2002, part number WS07X10018. DO NOT SUBSTITUTE TUBING OF UNKNOWN QUALITY. _-_ /_ needs to be removed RO "'4_. _ If you are using copper tubing, DO NOT connect it directly onto the RO unit. Purchase a connector and use a short length of the yellow banded tubing provided to make final connection to RO. Do not use copper tubing to attach to icemaker or faucet. , 11 Hand tighten inlet valve (F) into the adapter (C), then finish tightening with adjustable wrench. DO NOT USE WRENCH ON HEX NUT END OF VALVE AS LEAK MAY OCCUR. Installation Instructions FEED WATER SUPPLY (cont,) INSTALLING THE TUBING AND FAUCET TO TANK FLOW RESTRICTOR REPLACEMENT PROCEDURE (cont.) Measure 3/4" from the end of each remaining piece of tubing (faucet end and inlet end) and mark with a pencil. (Check for roundness, smoothness, cuts, nicks, flat spots and sharp edges). 1. Remove drain line tubing by pushing up on the drain line collet with one hand (1) 1, and removing the drain other hand (2). , INCORRECT . Push the tubing firmly into each fitting on the manifold until the line is flush with the fitting collar. (If the tubing is removed, recut the end, measure, mark and re-insert). Tubing must be fully inserted to avoid leaks. To remove tubing: depress and hold red or blue collet; pull tubing out to remove. Red or Blue Collet __///////_/ the restrictor is no longer in the end of the tubing, check the drain line port. Remove the restr_ctor from the port and proceed to step 3. I_ Insert tubing _ , /8" tubing) Pull out slightly good seal. on tubing i to ensure 4, Each time the Reverse Osmosis cartridge is changed, you will need to replace the flow restrictor in the drain line as well. before and slide it back into the a FLOW RESTRICTOR REPLACEMENT PROCEDURE Be sure to wash your hands inner parts of the system. Take new restrictor drain tubing. Insert the restrictor by hand only. Do not use pliers to insert. Make sure to insert restrictor all the way into the tubing. Failure to do so could result in improper operation of the RO system. _{3 ngagemenL_ 3/4" -I . Once the drain line has been removed from the system base, grasp the end of the flow restrictor and pull it straight out from the tube*. If the restrictor is difficult to remove by hand, a pair of pliers may be used to grip the end of the restrictor to aid in removal from the tubing. *In some instances, the restrictor may slide out of the dra_n tubing as it is removed from the drain line port. If, after removing the drain line as described _n step 1, (DO NOT REMOVE) _/. Insertion line with the handling 12 Reinsert drain line tubing in system base. Tug lightly on the tubing to ensure that the collet is engaged and has a proper grip on the tubing. Installation Instructions FAUCET ASSEMBLY FAUCET MOUNTING INSTALLATION 5. Be sure there is room underneath the sink to make the needed connections. Select one of the following locations to install the faucet: NOTE: To ease insertion, submerge tubing into hot water for a few minutes to soften. . • In an existing sink spray dispenser hole. attachment or soap • In a hole to be drilled in the sink top. • In a hole to be drilled next to the sink. in the countertop, 7. NOTE: Be sure the faucet base will fit flat against the surface at the selected location so the gasket will seal. . . Remove the faucet, thin o-ring (D), faucet base (E), bottom base gasket (F), lock washer (G), hex nut (H) and mounting bracket (I) from the packaging. Feed the 3/8" blue banded, 1/4" black tube (attached to the Reverse Osmosis System) and the 3/8" black tube (included in Feed the two black tubes up through gasket (F), faucet base (E) and O-ring _:_ Seat the base (E) and body (B) together. Make sure the O-ring and gasket are in place when the base meets the body. The faucet handle will be at the 3 o'clock position with respect to the base. Slide the lock washer onto the threaded stem of the body (B), then thread the hex nut (H) onto the stem. Screw about halfway up. 8. Screw the blue tipped tubing adapter (K) onto the threaded stem of the body (B). 9. Push the blue banded tubing into the adapter. It should go in about 3/4". Pull on it to make sure it is installed correctly. 10. Feed the tubing and stem through the 1-1/4" hole. back down 11. Lower the faucet assembly into place in the mounting hole and orient to final position. Place the mounting bracket (I) above the lock washer (G) around the faucet stem. While holding the mounting bracket in place, securely tighten the hex nut. This step may require two people. separate packaging) up through the mounting hole in the sink or countertop. This step may require two people to assemble. See page 14 for Optional One Person Faucet Tubing Installation. 4. ends NOTE: If installing faucet on a stainless steel sink, slide on installation spacer (M) before the lock washer. If drilling is needed, make a 1-1/4" dia. hole. Be sure to use the proper procedure for drilling porcelain or stainless steel. Special drill bits may be needed. Consult a qualified plumber for proper procedure. 1. Push the 1/4" black and 3/8" black tubing onto their respective fittings on the body (B). the (D). Spout 3/8" barb ASSEMBLED 4" barb fitting Cap Body {B) _ Installation spacer (M) 3s needed) Handle O*rlng _j IG) 3/8' (black) drain tubin_ (D) Hex Nut (H) Base (E) g adapter {K) Mounting bracket _..j (I) "_.__,_W _t_"_ nn n Gasket (F) Lock washer Hex nut (H) (G) Tubing adapter 1/4" (black) drain tubing 3/8" (blue (K) outlet NOTE: For ease of service and maintenance, keep tubing lengths long enough so removal of the Reverse Osmosis system from under the sink is possible. To drain 13 From RO From banded) tubing RO Installation FAUCET ASSEMBLY Instructions (cont,) OPTIONAL ONE PERSON FAUCET TUBING INSTALLATION 1. 2. 3. BATTERY INSTALLATION 1, Use a small flat blade screwdriver to remove the battery of the faucet base. tray or coin (A) at the side From under the sink, gather the 1/4" drain line (black), 3/8" drain line (black) and 3/8" outlet tube (blue banded) in one hand with 2. the drain tubes the same length outlet tube offset approximately Install one CR2032, 3 volt battery (B) + side down into the battery tray (A). 3. Slide tray into faucet battery tray (A) edge of the base. 4. The blue light (D) will flash 5 times, indicating a proper installation and system reset. If you want to reinitiate the start-up sequence, remove the battery for 45-60 seconds; the electronics need to fully discharge. Then put the battery back in. 5. The light is normally off. After 6 months of use, the light will flash again every 30 seconds, indicating the proper time to replace the filter cartridge. Wrap a rubber band around Insert a typical No. 2 pencil rubber band location. and the 6 inches. all 3 tubes. through the base (C) until the is flush with the side NOTE: The blue light may stop blinking if allowed to blink for an extended period of time. To ensure proper operation, the battery should be replaced with every filter change. 4. (D) Blue light Rotate the pencil down until it is in line with the tubing and push up through the mounting hole. Release the grip on the pencil and the tubes will remain in position for easier faucet connection. J (C) Faucet base _ AB atta_....._@ ( ) tray 14 (B) Battery Installation Instructions FILTRATION DRAIN CONNECTION Check and comply with CAUTION: configurations. local plumbing The options codes as you plan. detailed below Do not use any drain saddle are the ONLY approved installation device. NOTE: Failure to follow these Installation Instructions will void the warranty, be responsible for any service, repair or damages caused thereby. and the installer will PREFERRED INSTALLATION: OPTION AmBASEMENT ACCESS INSTALLATION PREFERRED INSTALLATION: OPTION B--ORY-VENTED P-TRAP INSTALLATION Route the drain line DIRECTLY from the Reverse Osmosis system to a standpipe in the basement, bypassing the air gap provided in the faucet. The air gap installation is left to the discretion of the installer. The drain line may also be routed to a floor drain or washtub, provided that the air gap is maintained. Special air gap fittings are available to connect the drain line to the top of the standpipe. Install a separate dry-vented p-trap under the sink to be used exclusively for the Reserve Osmosis drain line. A dry-vented p-trap is a p-trap that has its own vent/stack. Attach the drain line adapter to the p-trap and secure it with the slip joint nut and washer as shown. The drain line MUST be routed through the air gap provided in the RO water faucet. Drain llne from the Reverse Osmosis system Reverse Osmosis drain llne "_ _ _ _" _ _1] ,/[I- i ___J Opti 1" m_n_mum air gap must be maintained 15 " oser Installation FILTRATION Instructions DRAIN CONNECTION PREFERRED INSTALLATION: OPTION C--WET-VENTED P-TRAP INSTALLATION SECONDARY INSTALLATION: OPTION DmDRAIN LINE ADAPTER INSTALLATION Install a p-trap under the sink to be used exclusively for the Reverse Osmosis drain line. A wet-vented p-trap is a p-trap that shares a common vent/stack. Attach the drain line adapter to the p-trap and secure it with the slip joint nut and washer as shown. The drain line MUST be routed through the air gap provided in the RO water faucet. Locate the Reverse Osmosis p-trap as high as possible (minimum of 4" above horizontal). Reverse _t'_'_'L Osmosis / I t "_"t J drain,he k',fl _) _ i! JJ Ir I I " CAUTION: Using Option O may result in clogging under adverse conditions and requires periodic inspection/cleaning by the user. DO NOT INSTALL THE DRAIN UNE DOWNSTREAM OF A DISPOSER OR IN A HORIZONTAL PIPE. Install the drain line adapter under the sink as shown (parts included). The baffle tee shown must be installed to prevent a clog in the Reverse Osmosis drain line. Route the drain line from the air gap to the drain line adapter, ensuring that there are no dips, loops or low spots in the line. The drain line adapter should be aligned vertically so that the hose connection points upward (the hose connection should never be allowed to drop below 45 ° from this vertical position). This installation MAY result in a slight drain noise in the sink drain when the Reverse Osmosis system is regenerating. If this happens, simply place the sink drain stoppers in the strainer to suppress it. "- - -' Optional (cont.) d_sposer Maximum 45 ° verse smosis ain line ^T, II _'y "'_.,'"' disposer t,.U] _ Optional F II ft_ Drainline _5311z_' adapter -_-"'-" Fro '(_m '_ second sink or disposer \ Drain line connection should be 180 ° opposite existing horizontal pipe/baffle-tee shown in diagram Proper drain line adapter orientation. _n 16 line adapter as Installation Instructions STORAGE TANK AND STARTUP STORAGE TANK INSTALLATION Remove the protective of the tank. 1. 2. . cap from SYSTEM STARTUP PROCEDURE A_^| |-i-=r_R, LLt.p/'_U/IUI_I: If installing the unit in new construction, ensure that house plumbing is flushed thoroughly before opening the water supply valve. the top Apply 2-3 wraps of thread tape, in a clockwise direction, to the tank threads. Install the push-to-connect fittings on the threaded fitting on the tank as shown. Storage tank 4. Push the 3/8" red banded Reverse Osmosis System on the storage tank. tubing from the into the fitting 17 1. Check that all tubing secure. connections 2. Turn on the Feed Water 3. Check all connection 4. Follow the Sanitization page 19. 5. After sanitization prefilter, postfilter cartridges. 6. Membrane contains a food grade preservative. Allow the system to fill the tank, then drain it completely four times before using the water from the system. 7. Recheck all water connection days later to check for small Supply points are Valve. for leaks. procedures on is complete, reinstall and Reverse Osmosis points leaks. a few Care and cleaning of the reverse osmosissystem. Prefilter, Postfilter and Reverse Osmosis Membrane Wheu tile hlue light in tile fbucet hase flashes, it is liIite lo replace the prefiher This will occur every 6 months. Be sure to wash your hands inner parts of tile sys/eIn. I. "Ibm OFF tile icema_er flle system). and befi)re postfiher. haudliug (ifatlached m Cartridge Replacement Procedure 6. ReInove fbil on top of uew replacement cartridges. Install new cartridges into Ihe mmfifbld hy mining m tile fight about 1/3 turn until dm aligmnent marks line tip mid Ihe cartridges stop. DO NOTOVBCTI6HIEN. Tile cartridges will rise tip as alley are mined. Z Turn ON water supply m fill die systetll (may take up m fimr hours). Check for leaks. ReInove ltle battery tray aud replace tile bal/ery to remt fiIner and monilor fimction in faucet ba.'.;e(_e Battery Installation fbr proper procedure). 2. "Ibm offwater supply m die sysleIll. 9. If only tile prefiher and postfiher are replaced, mm the fbucet ON and empty the filled storage lauk. If the memhraue cartridge is replaced, fill aud emp/y tile storage rauk a total of four times. (This will remuve the food grade preservatives contained in new membraues. This premrvafive will give product water an unplea-sm_t tasle and eden) I0. Once dm storage iceInaker. tauk is thll, mm ou file 3. Turn ON faucet to draintauk (may take several Ininutes). Turn OFF faucet when tauk is emp/y. 4. Remove tile prefilter, postfilter aud Reverm Osmosis cartridge hy rulafing to file left about 1/3 ram. NOTE.," System should he sauifized when replacing file prefiher aud poslfiher carlridge or the Reverse Osmosis cartridge. Follow the Sanitizing tha Reverse Osmosis Systam procedure on page 19. Prefi[terl Reve_el Osmosisl Postfi[tel To remove Follow Sanitizing the Reverse Osmosis System procedure found on page 19. 18 www.GEAppliances.com Sanitizing the Reverse Osmosis System Sanitize upon installadon of the Reverse OsIllosis systeln and after ser_4cing inner parts, including replacement of prefilter, posttiher and the IneInbrane cartridge. Be sure to wash your bands inner parts of the syslem. before handling A CAUTION:_ef_,re smlidzing, tile I. Follow steps 1 through 4 under Prefiltor, Posffilter and Reverse Osmosis Membrane Cartridge Replacement Procedure. 2 5. TurIl fhucet ON and allow water m flow fbr 20 minutes, or until bleach udor is gune. "Ibm OFF waler supply again. "I_m ON faucet m drain tile sys/eIn. be sure to remove all carlridges. (iblorine will destruy Reverse Osmosis Inembrane carlridge. 4. Turn ON waler supply. Turn ON fimcet until W_aler begins lo flow from 1tie faucet, then Illrn tZaucel OFE Allow system m fill for 10 minutes. 6. Once die system and remove tile about 1/3 turn. needed tile next is drained, mm tile fhucet OFF canisters by mining m die left Keep the_ in a safe place undl time. Fill file eInpty caIfister labeled "Sanifizalion C_mister" wifll waler lx_within 1 inch of die tipper opening. Add 1 oz. (2 Tbsp.) ordinary household bleach. Install canister into tile prefilter canister position by turning m the right aixmt 1/3 mm until die _ligmment Inark_; line up and die canister stops. "_-.,..,...,_ Prefilter position 3. Install die two additional "sanifiziafion cmfislers" inlo die meInbrane canister and postflher openings in die manifold by turlling to lbe right aixmt 1/3 mm until die aligmment marks line up and die canismr stops. Sanitization canisters 79 Care and cleaning of the reverse osmosissystem. To obtain replacement filters, call toll-free GE Appfiance Parts at 800.626.2002 (UoS.), 800.663.6060 (Canada-English), 800.361.3869 (Canada-French), or visit the store where you purchased your reverse osmosis system. Pmfilter/PostfilterCartridgeReplacementFQROPF Reverse Osmosis Cartridge Replacement FQROMF A_ I'J AI,_I.I UTION; t CadJonBIock Thin Film Polyamide Before servicing the Reverse Osmosis system, close the water supply/saddle valve and open the RO water faucet. Allow the system to drain. The Water Test Kit To obtain an independent laboratory water test kit, please call Legend Technical Services at 1.800.826.8553 ext. 47 and leave your conlact details. They will contact you to find out what wa/er lests you are interested in, and infi)rIn you of the cost of the testing. You will then receive a kit that will include all necessary tests to properly indicate the perfi)rmance level of your system. Product water should be lested a minimum of every six monlhs. NOTE:When the TDS reduction of the system falls below 75%, it is time to replace osmosis carlridge in addition to the prefilter and pos/filter. 2O the reverse Before you call for service.., www.GEAppliances.com Troubleshooting tips Save time and money! Reviewthe charts on the following pages first and you may not need to call for service. Problem Possible Causes What To Do Water has air bubbles and is cloudy Air in system after installation. * Will go away after it runs fi_r a while. Indicator light on faucet base not working Batteries installed or expended. * Ohserve Replace orientation on page 14 and install correctly. bat|eries ifold. Blue light does not illuminate until 6 months. * Normal operation. Batteries * Use new CR2032, Chlorine taste and/or odor in the Reverse Osmosis product water Other taste and/or odor incorrectly are dead. _volt batlery. The ppm of chlorine in your water supply exceeds maximum limits and has deslroyed the Reverse Osmosis membrane, * If the water supply contains more than 2.0 ppm of chlorine, additional filtering of file water supply to tile Reverse Osmosis is needed. Correct this condition before doing maintenmlce on the Reverse OsInosis sys/eIn. Tile pref'flter is no longer removing c_orine from the water supply, • Replace the Reverse Osmosis flow control, _'reen, prefiher, in die eleoronics box. High quality product water may have a different taste than what you're used to. • This is norInal. Low water usage. • CoInple/ely Con "taminafion * Use sanitizing in product membrane carlridge, posffiher mid batteries drain sys{eIn mid allow |o refill. procedures. water storage. Prefilter and postfilter * Replace the prefiher mad posLfiher. need to be changed. * SaIfitize system. Waterleaking from faucet air gap bole Drain side of faucet air gap (3/8" tubing) plugged, restricted or incorrectly connected to the drain. • Inspect and eliminate restriction or plug. It is important dial fllere are IlO dips, loops or low spots in file drain line from tile f,mcet air gap to the drain pipe. Reter to Installation lllstrucfions for proper drain connection. ffdrain line adapter was used as the drain point, periodic inspecfioll/clemfing is recommended. System makes product water slowly Tiffs is normal. • Water flow rme will be lower tllan your regular • It takes .%4 hours 1o fill tile tmlk. Water supply to the Reverse Osmosis system not within specifications, • Increase water pressure, precondition the water, etc, as needed to confbnn hefore doing lnaimellance on the Reverse Osmosis system. Prefilter cartridge plugged with sediments, • Replace the prefilter. If rate does not incre_Lse, replace the postfilter, Rever_ Osmosis membrane cartridge, flow comrol and batteries in file faucet base. Reverse Osmosis plugged with sediments. fauco. membrane 27 Before you call for service... Troubleshooting tips Problem Possible Causes What To Do NOWater Water supply valve • Turn water supply valve on. See diagram on page 11. not turned on. After filter change, tank is empty, • It takes .%4 hours for RO system to provide enough waler m fill file tank. Leaksat fittings Improperly • Reinstall. See Installation lnstrucfiuns. Soundsyoumayhear Sink drain, drain water • This is normal. from system. • Drain line can be installed Io an alternative drain, such as a tya_sement drain. See pages 15 and 16 for aherImfive drain configurafioIls. Faucet air gap--draln water flowing through the faucet air gap. This may be associated with high pressure water supply, generally 90 psi or greater. • Install a pressure regulalor in the house water supply system to reduce the pressure below 90 psi. 22 installed. • _ allernafive flow reslrictor for high pressure inslallafions is m_lable from GE (see item #31 on the parts list, page 25). Contact GE Parts aa_d ask for Flow Reslricmr, High Pressure, Part Number WS15X10049. m Notes. www.GEAppliances, com m _qk m m _qk 23 Parts lisL PXRQ r- 15F, PNRQI5FBL ....... I I I I I OPTIONAL PARTS FOR REMOTE INSTALLATION 24 Parts catalog, ww_.GEAppliances.com QUANTITY P N P R X R Q 1 Q 1 5 F 5 B RKF. NO. GE PART NO. PART DESCRIPTION F L 0001 0002 0003 0004 0005 0006 0007 0008 WS19X10017 WS19XI0018 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0009 0011 0014 0015 0016 0017 0019 0020 0021 0022 0023 0024 0027 0028 0029 0030 0031 0999 WS02X 10034 WS32X10021 WS07X 10018 WS07X 10019 WS15X10037 WS 10X 10028 WS 18X 10009 WS02X 10031 WS35X 10041 WS15X10041 WS22X 10055 WS22X 10054 WS22X 10052 WS22X 10053 WS 18X 10006 WS02X 10030 WS 15X 10049 49-50144 MANIFOLD ASSEMBLY HOOD PRE AND POSTF1LTER SET RO CARTRIDGE O-RING KIT (4 LG, 6 SM) FLOW METER CAP & O-RING SHUT-OFF VALVE ASSEMBLY SHUT-OFF COVER & CHECK BALL ASSEMBLY SCREWS, SET OF 7 WATER STORAGE TANK TUBING, 1/4" D1A. X 33'--WHITE TUBING, 3/8" D1A. X 33'--WHITE FAUCE'I. CHROME, LONG REACH FAUCET BASE, CHROME FEED WATER ADAPTER KIT WASHER & NUT FAUCET SAN1T1ZATION KIT FLOW RESTR1CTOR TANK CONNECTOR, 3/8" TUBE FAUCET F1TI'ING, 3/8" TUBE COLLE'I. 1/4" (SET OF 2) COLLE'I. 3/8" (SET OF 2) DRAIN LINE ADAPTER SPACER, FAUCET MOUNT FLOW RESTR1CTOR, HIGH PRESSURE OWNER'S MANUAL & INSTALLATION INSTRUCTIONS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FQROPF FQROMF WSOBX 10047 WSOBX 10048 WS 15X 10040 WS10X10030 25 GE Reverse OsmosisSystem Warranty. Ag warranty service provided by our SmartWater Authorized Servicer Network. To schedule service on-line, 24 hours a day, contact us at www.GEAppliances.com, or cag toll-free 800.G£ CARES (U.S.), or 866.777.7627(Canada). Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty. TM _ GE Will Replace: AnypattoftheRever_OsnmsisFihrationSystemwhichfailsduetoadefectinnmterialsor w_rkm_nship_ During this _imited _ne_year Watranty` GE wi_ _s_ _r_x4de_ _ree _f cha_e_ M_ _al_r (does not include service trip to home) to replace the de_ecdve part. All warranty _rt4ce will be pro_4ded • Service trips to your home product. • Improper installation, by a GE SmarlWater TM to teach you how to use the delivery or maintenance. • Failure of the product if it is abused, for other than the intended purpose. nfisused, or used Authorized Servicer. • Use of this product where water is nficTobiologlcany unsafe or of unlmown quality, without adequate disinfection. Systenxs certified for cyst reduction nmy be used on disinfected water that may contain filterable cysts. • Replacement breakers. of house fuses or resetting of circuit • Filters or membranes. • Defects that result from inlproper not caused by GE. installation or damage • Liability on the part of GE under this or any other warranty for any indirect or consequential "danmge. • Products that are used for commercial • Danmge to the product caused by accident, acts of God. Fwe, floods or • Incidental or consequential defects with tiffs appliance. by possible • Danmge damage caused caused after delivery. or industrial applicadous. This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General THIS WARRANTY IS INTENDED TO BE IN LIEU OF ALL OTHERWARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Warrantor: General Electric Company. Louisville, KY 40225 26 Lasection Fran aise. Mesures Mesures de s_curit_ de s_cnrit_ .................. Guide des specifications 28 .............. 29 €'t Fonctionnement Au sujet du syst_me de filtration osmose invers_e .................. par 30, 31 m Instructions d'installation Alimentation d'eau Avant de commencer ............... 35-38 l'installation Installation Installation de la pile ................. du robinet ............. Installation du sysu?me de montage . . .32, 33 ..... Outillage et matdriel requis ............ Raccordements/_ la conduite de vidange Rdservoir ..................... de stockage 32 ..... Entretien et nettoyage Aseptisation ....................... Remplacement des cartouches au consommateur Garande ........................... Liste des pieces/catalogue Souden au consommateur 43 45 pr&filtre, post-filtre et osmose invei_de Trousse pour le test d'eau ............. Soutien 34 41, 42 et d_marrage Consei ls de d_pannage €'t 40 39, 40 ........... ..... 44 46 47, 48 53 .......... ............ 50, 51 54 t4_ Transcrivez les num_ros de modOle et de serie ici : # de modOle m # de serie Vuus les trouverez de filtre. sur le support du corps 27 _" MESURESDE SI CURITI IMPORTANTES. LISEZD'ABORDTOUTESLESINSTRUCtiONS. Pour votre sdcurit#, suivez les instructions foumies dans le present AVERTISSEMENT!manuel afin de minimiser les risques de dommages au materiel ou de blessures corporelles. PRECAUTIONS DESECURITE : _ A VERTISSEMENT:N'utilisez pasl'appar • "_]_fi_'z avec It's travatLx publics locaux ou de vet r( _tat quds son[ It's codc_ r(:[_tissall t la plombel_e (t It's a111_l]age lla( l] L_; saltitaires. V()tLs de_TeZ ,'arts y con fonller l()rs de l'ii_st alia(ion du syst_me du s}_t c"me de fhration pal- (xsmose invers_e. recommand(_ de faire appel g_un installateur qualilie. • Host Si la pr( ssion de l *c_au affluent gt l'habitation d_p&_s( la val cur maximalc de 120 li_Tc_/po2, montez un d_tendeur dam la conduite d'arriv_e de 1' c_au au _2_t_'me de filtration. (2(" sysff'me _ _td testd pour le traitement de 1*c_au contenm_t de l'mxenk pentavalent (amsi appel_ AS(V), As(+5) ou aasg,niat e) gt une concentration de 0,050 mg/L ou mains. Ce sysff'me r_duit l'al_nic pentkt'salenl, illais peut ne pas retir(_r d'autres f() 11llc's d'arsenic. Ce systg'me doit {:(re utilis_ darts les _imentations en eau comcnant du chlore libre rdsiduel ddtectahle ou darts les • Assttrez_vot_ que l'eau est confonne au Guide des sp#cifica_ons. Si ]mscorzditioi_s (I_ ]'ean n_, sont i_s I'o]_nlles, rontacLez vail t! compagnir municipale de fourniturt! d'eau ou voice sez'¢it't ' (k" saalt_ local pour obt enir ",In(* list(* dL_; agen LS de contalnination de vouc r_gion et une liste des laboratoires homoh)gu_'s [Jar votrr _tat pour l'analyse de l'rau de tahlr. 4, 4L AVERTISSEMENT: t-il avec de l'eau qui n'est _as sfre microbioh)giquement ou de qualit_ incomme saris qu'elle n'ait {}td d_sinfectde avant de o apr_'s que le s)'sff-me. Lts appa_( ils homologxz(_ pour la r_duction d(s spores peuvent _tre u tilis(_ pour le filt rage de l*emi qui a _/_ d(*sin fect de pouvoal t con/_-nir des spore's filtrables. alimentati(ms ell call qtli se sent avdrte._ contenir st*tllelazent de l'a_x:nic pentavalent, lx" traitement _ la chloramine (dflore COlilhiill_ ) ll't'st p;&s Sllfi]saIl t pour assurer la coilveY2_O ii compl{4e dc l'arsenic t_ivalent en _nic pentavalent. Veuinez lire la se_ (ion Fairs sur l'al_nic de la fche technique de pertormance pour des renseignements s_lppl_mentairc's. premi ,,tili r " tion s)_t g'me de filtration, celui-ci doit _'tre purge. La car touche du s}_;t_"nle de filtration par oslnosl _ invers£'e contient tin pr_st*watif [x*ur aliments qui doit _*tre pu*g_ du s}_ff'me. C_ pr_}servatif donne it ]*c_au un go'Jlt et une odeur d,Z_r_abl_ _& Cet appareil comport(" une car touche avec hie llabr_Llle rempla_ able essentidle pour r(!duir t! etf(_cement les lnati_res sx)lides tolalement dis_x)lv'ables. 11est not c_saire de letter l'eau pdfiodiquement afin de s'a_*;surer que de manil'we sa tisl_2_kvante. l'appm'eil thnctionne INSTALLATIONETENTRETIENDU SYSTeLME Avant son utilisation, le systdme de filtration doit Otre correctement installd et positionn# conformdment aux instructions d'installation. • • h_slallez l'appareil ou entr t_osez-le de telle _a_m qu'il ne soit pas exp(_/_ des _mp_ramres inf_rieures au point de cong_lation ou non _Ll'al)ri de tout type de _)rlditions nl_tex)rol(_que. II sel-a endonli[Z_ i_ar l'eau qtti se cong_qe. N'e_sayez i_a_ de t_Ler (_ l*c_au dont la _mp_Fat/lre est suF,_ri_*re _ 1(_) degr_s E • A ILkAVERTI55EMENT: pas l'appareil sur une CONDUITE D'EAU BOUILLANT£ Ial temp_Sramre de l'(rau mTiV,m t au S}_tg'me dolt se trouvt!r enlre 4f°F au IllinhllUIll et I(X)°F au l_l_xiill HIll. Ne blanchez Voy_ le Guide des Periode prolongee de non-utilisation du s_e de filtration. Si le sy_t_'me n'a pas 4td utilis_ au cou*s d'unr p_riodc d'unc selnaine OU phts, Ot#,TeZ le robint*t d *(rau RO pain" p(,nxlettre la _4(langc de cehfi4;i. Fermez le rohinet pour permettez au spsl_me de z_gdndrer l'alimentation en e-au. • L'insta]l_tion recommand_e L_stSOLZS l'_e z_Toutefois, peut &re insm]l_e dales un lieu _loigu_, jusqu'$ de 6 m (20 pi) de l'C'_4en • ( 5ependant, des mat_riaux suppl_mcntaires ( kmsultez la listc de pi_'ces pour commarlder _p_men_res chez GE, • seront n_ce_vaires. les mat _riaux • Si VOLTSplacez It* r_serv_r s_tr un plarlcher de sot_s-sol, avec le robinet gt l'_ier du premier _tage, vous pouvez ob_nir une r&luction du taux de d_bit ('t de la caFacitd (d'em_ron 20 %). Vous arn_liorerez ce rendement rn ins(allan( un det_xi_'*me • Ce sysff'me traitement les solides ('e produit fonctionne (z-¥(}i l _ de lOllS l(._: eOsinfec_on du syst_me de filtration d'osmose invel_e (_mtient u*_ _l_ment de remplagable essendel pour r_duire et ficacement u)taux dis.sorts. Vous devez tester p&Jodiquement (lans l'eau pour vuus _._urer que le s}_t c"ille bien. ( kmsultez la secdon Trousse do tostd'eau. ASSUREZ-VOUS OUE VOUS SUIVEZ TOUTS DE VOS CODES O'ETAT ET LOCAU)_ r_sl'rvoii: Votts pottvez utiliser le RVKI_ VEUILLEZ LIREETSUIVREATTENTIVEMENT CESMESURES DESECURITE. CONSERVEZCESINSTRUCtiONS 28 (} hal-l-&£_; 1)_sinti:ctez les _ldments au cours de l'installafion et aprbs l'entretirn d('s composants h]ternes. Ct!d inch]t le remplacement de l'&l_Sment de pr_2_f Itrage, l'£'l_ment du post-flhrage et de la car t, roche de l'appareil. II est impor tm_t clue les mair_s sx)ien t propres lots de la mmtipulation des _l_ments int_naaes du sysff'me. Vo)[ez la s_eetion par OSt#OSOiDversee. l'unit( _ une distance D comp(_ants nol]-utilisds ainsi que de l'emhallage aprbs l'installation. 1_ petites pi&ces qui rcstent aprg's l'installation peuvent consdtuer un danger d*_touffement si ing_r_es. specifications. • Si le sysff'me de fh[ arian par osmose inversde est raccord_ il la machine fi gla_)r_ du _fi-ig(xat cur, un kit _cial pour la connexion de la machine/_ gla_:ons cst n_re ( R_dIT). N'utilisez ]_&sde ruins en c ui'vTe pour la c01]nexion entre le Syst_r[ze de filtration par osmose in_rs_e et le r_frig_r'ateun __ Guide des sp6cifications. Produit- hauteur 1l po (28cm) largeur 10,5po(26,7 cm) profondeur4po (10 cm) Le syst_me prepare chaque.iour mm bonne quantil_ d'eau Cette quantit_ d_pend principalement des facteurs suivants... Limites de pression de I"eau d"alimentationilivres potable. par pouce carr_ (psi) ............ Limites de temperature de I'eau d'alimentationiminimum/maximum 40-120 _ en degr_s F .... 40-100 Maximum de solides dissoustotaux (TDS)--parts par million (ppm) ................. 2000 Maximum de durete d'eau @ pH 6,9 recommande pour optimiser la duree de vie de la membrane--grains par gallon (gpg) ........................... 10 8 7,5 Pour une duret# d'eau sup#rieure _ 10grains (_ un pH de 6,9), nous _ recommandonsd'utiliserunadoucisseu_Sivousn'installezpasun adoucisseur d'eau, vous r_duirez la dur_e de vie de la membrane d'osmose invers_e. Consultez le tableau pour de plus amples informations sur le besoin possible d'un adoucisseur d'eau. ! , _ 6,s _0 20 30 40 50 [R_ET_ OE L'_AU D'ALIMEh_TATIOR{G_G} Maximum de fer, de manganese, d'hydrog_ne suffure (ppm) ..... <0, I Chlare daus I'approvisiauuemeut 2,0 ppm maximum permissible b d'ea# ...................... Limites de pH de I'ea# d'alimeutatieu Capacit_ du reservoirigallons (ptl) .................... 4-10 (litres) ....................... 4 ga I ( 15,I I)_ Contr_le automatique d'arr_t ............................... oui Pr&filtre et post4iltre (FQROPF) bloc de carbone .................................... Membrane d'osmose inversee ............................. (FQROMF) pe//ieu/e fine de polyamide Dimensions du r_servoir ................................... hauteur 15po (38 cm) diam_tre 11po (28 cm) Dimensions du corps hauteur 11po (28 cm) largeur 10,5po (26,7cm) profondeur 4 po (10 era) a. Si la pression d'eau d'approvisiormement reiou]elnent d'osmose ..................................... de la maison est sup_rieure gt 120 psi, ir_stallez d'eau. Si ]a pression de l'em] de la maison ir_w'rs_e (appelez votre iournisseur local b. EnlevO (maximum de 2,0 ppm) la memblane d*OslllOSe iilvers_e. c. Capacitd thdorique d'approvisiom_ement par le filtre du r_servoir. (_Ualtd d'eau, la capacit_ d'osmose inversde. un robinet de rOduction de pression est ir_f0_rieure _ 40 psi, installez de produi_ de plomberie). ENTRETIENR_GULIERREQUIS. il est essay_5 conform_ment gtla norm( 58 NSF/ANSI du rdservoir est dg-ale ;i 2,3 galkms (8,7 1). une Le chlore sur le tuFau pompe de dOtruira gt 50 psig de pression 29 Au sujet dusystemede filtration par osmoseinvers e. Ce que ce syst_me accomplit Le systi:me de filtration par osInose inversde rdduit les mati(Sres solides mlalement dissoules (TDS) ainsi que les maliieres organiques de l'eau par diffi_sion an travers d'une membrane spdciale. Cetle membrane sdpare les mati(Sres min_rales et les impuretds de l'eau, lesquelles sont (&,acudes dans le tuyau de vidange. L'eau de haute qualitd produite est acheminde directement au robinet d'alimenlation en era1 potable ou an rdserw>in L'appareil produit une bonne quanliu: d'eau polable quotidiermeIneIm La quan/i/_ d'eau produite est fbnclion de la pression d'eau d'alimentalion, de sa leInpdramre et de sa quality:. Les prd-fibre el Ix)sl,fillre au charbon sont des cartouches remplagables. Le prd-filtre dlimine le chlore et filtre les s_diments. Le Ix)sl-filtre _limine les gofits et les odeurs ind_sirables avant l'utilisation de l'eau. Ces syst&mescomprenImnt tm ensemble de robinet _lectronique avec rappel de changement de pr&filtre et de posl-filtre. "Ibm les six tools, une lumi&re clignotante bleue vous rappelle qu'il faut changer les deux fillres. Description du systeme de filtration par osmose inveraee _Pr6-filtre--_ eau en prmenance de la condmte d eau fi'olde est dirig_e darts la cartouche du pr_-filtre. Le pr&filtre esl une carlouche de r(_cup(_ralion des s_diments remplaqable qui contient du charbon acti£ 11 rdduit la quantil_ de chlore de l'eau, lequel O'_TRUITLA MEMBRANE OU SYSTEME.L'eau propre, filtrde et gt teneur de chlore rdduite s'_coule du prdfiltre vers la cartouche du sys/aaIne. _Cartouche du systemede filtrationpar osmose invers_e---La comprelld lille membralle {[roitetnelll serde. L'eml est fbrc_e au travers de la carmuche off la mmnbrane r&luit les matiOres solides dLssoutes et les maii&res organiques. L'eau trait_e & hmlle qualitd sort du logement du syst_me et se dirige vers le rSservc4r.L'eml rejet_e contenant les mati_res solides diss(mtes et les d_chets organiques quitle le logement puis est d_charg_e _ l'ofifice & vidange au paxsmlt l_ar la con&rite de 1/4 po. cartouclle dll milieu _Post-filtre--Apr_s axoir quittd le r_servoir mais a_aIl|_ d _tre * acheminde an robinet du syst_me, l eau produite s ficoule vers le post-fihre se lrom,ant darts le corps de fihre. Le pos_fibre est aussi une cartouche de fibration des s_dimenls rempla<-able conlenant du charbon acliL "Ibut reliquat de gofits, d'odeur ou de s_diInents sont _limin_s de l'eau par le post-filtre. L'ean polable propre de hame qualil_ s'_coule par la conduile vers le robinet du sysl_Ine. _Re, se_oir--Ler_r, oir condentjusqu _ 2,5 gallons (@ l) dean trait_e. A l int,frieur, un diaphragme maindent I eau sous pression lorsque le rdservoir est plein de fa_:on gtassurer une ddbit rapide *ers le robinet lorsque l on d_sire avoir de l'eau ix)table. 3O www, electromenagersge.ca [_tClapet pourrait anti-retour--_ entvahmr dapet emp_che le refbulemem de l'eau la rupture de la membraIm du systbme. tvait_e en provenance du rfiservoir. UII tel refoulement _Robinet d'arr6t automatique---Dansle but de con_rver l'eau, le systOt_m de production d'eau potable comporte un robinet d arrat automatique. Lorsque le rOservoir est plein et que le robinet d alimentation en eau potable est fk_rmfi, la pres_sion ferme l'appareil. Le d_bit d'eau vers le logement du systame de filtration par osmose invers_e est inte*Tompu ju_u'_t ce que I eau potable m t a nomeau utfltsee et que la presszo _ chute dans le systame. F_R_gulation de d_bit-_e r_gulateur de ddbit contr61e de filtration pour obteIfir la valeur requise n_cessaire le tuyau de vidange de 1/4 po sortanl du distributeur. le d_bil de l'eau 5. la production au travers de la cartouche du syst&me d eau de haute qualit& II est situ_ sur _Robinet et _/ectronique-_ robinet du comploir fail couler de l'eau potable filtr_e quand on l'ouvre. !l a un levier manuel de r_glage de d_bils variables. Le robinet reste ouvert quand Oil 61_"N main du levier, d& que I eau a commenc_ 5. couler. Contbim&nent attx codes de ploinberie, un _cart anli-retour est construit dans le raccord de renvoi du robinet. Le robinet (?lectronique comporte une minutefie de six mois pour vous rappeler que vous devez remplacer volre pr&filtre el votre post-filtre. Remplacez les fihres quand la lumiiere bleue coIninence it clignoler, pour prot_ger la me*nbrane d osmose mversee et premrt er le/xm fkmcuonneInent du systeme. 31 Instructions d'installation I www.electromenagersge.ca i vous avez des questions, Systemede filtrationosmoseinverse Modeles appelez le 1.800.361.3400 _k AVE RTISSE M ENT : PXRQ15F st PNRQ15FBL ou visitez notre site Web & I'adresse I : Usez en totalite ce manuel. Si vous ne suivez pas toutes ses r_gles et ses directives, vous pouvez provoquer des blessures corporelles ou des dommages materiels. • Verifiez les codes de plomberie aupr_s des services de travaux publics de votre letat/province de votre collectivitY. Vous devez suivre leurs directives pour installer le syst_me de filtration et/ou des eaux. NOTE : Si vous ne vous conformez pas a ces instructions d'installation, vous annulez la garantie du produit, et rinstallateur devient responsable de tout service, reparation ou dommage occasionn_ par le syst_me. OUTILLAGE ET MATI'-'RIEL REQUIS POUR L'INSTALLATION AVANT DE COMMENCER L'INSTALLATION • Perceuse et meche de perceuse de 1-1/4 po (du type necessaire) si le montage est requis pour le robinet Veuillez lire toutes les directives attentivement. • Deux (2) clefs • IMPORTANT - Conse_ez ces instructions reglables les ordonnances • Ruban-metre normaux et Phillips •• Pour • L'installateur installer. LISTE DES COMPOSANTS 6viter • Imprimes • Feuillet concernant de donn6es • Adaptateur • Ensemble I'appareil (manuel relatives d'alimentation de robinet invers6e et conduite d'utilisation et robinet avec moniteur d'alimentation 61ectronique de base et tuyau • Reservoir • Adaptateur de la conduite et d'installation) a la performance d'eau de bien • Un robinet d'arr_t dolt _tre disponible ajout6 & c6t6 du point d'installation. DE L'APPAREIL par osmose est responsable ces • route panne du produit due a une mauvaise installation n'est pas couverte la garantie. d'endommager 1'6vier, consultez un plombier ou un installateur qualifi6 avant de percer les trous. Vous avez peut-_tre besoin de meches de perceuse sp6ciales pour la porcelaine ou I'acier inoxydable. de filtration Iocaux. • Avis au consommateur - Conservez instructions pour ref6rence future. • Si votre canalisation principale d'eau est un tuyau rigide, vous avez besoin d'une bague de compression et peut-_tre d'autres 61ements de plomberie pour terminer I'installation. • Ensemble et les codes • Avis _ I'installateur - Assurez-vous de laisser ces instructions au consommateur. • Couteau AATTENTION local. • IMPORTANT - Respectez toutes • Meche de perceuse de 1/16 po (en option pour les trous de guidage) • Tournevis pour I'inspecteur de vidange 32 ou par Instructions d'installation Points b verifier avant de commencer Robinet d'eau Tuyau de vidange produlte I'installation Re passant au travers de 1'4vier ou le comptoir de 3/8 po (heir) _o {17,8 cm) Tuyau de vldange de 1/4 po (noir) ,_ Tuyau de sortie de 3/8 po {raye de bleu) Tuyau d'entree de 1/4 po (ray4 dejaune) T 15 po {38 cm) 11 po (28 cm) Tuyau r4servoir Dia, de stockage 9 po 3/8 {23 cm) DI_TAIL DES TUYAUX/DU Pr_-filtre Membrane du de po de (ray4 de rouge) {26,7 cm) RACCORD DU SYSTEME DE FILTRAGE A LA VIDANGE FILTRE Post-filtre L'eau 6vacu6e provenant de la membrane du systeme de filtration n6cessite un point de vidange appropri6 et un espace d'air (verifiez vos codes Iocaux). Tuyau d'entr&e de 1/4 po (ray& de jaune) pa_tant du robinet d'atimentation Tuyau de 1/4 po (heir) allant au robinet Tuyau de 3/8 po (ray_ de rouge) allant au r_servolr de stockage Tuyau de 3/8 po (raye de bteu) atlant au robinet ROBINET Le robinet d'eau produite Re est mont_ sur I'_vier ou sur le comptoir a proximit_ de I'_vier. Souvent, il est mont_ dans I'orifice de I'arrosoir existant ou vous pouvez percer un trou. II est n_cessaire de disposer d'un espace suffisant sous I'_vier ou le comptoir pour la conduite reli_e au robinet ou en provenance de celui-ci et pour le montage du robinet. Tous los raccordements de robinet sent effectu_s sur ou au EAU D'ALIMENTATION L'eau alimentant le systeme de filtration par osmose inversee mont6 sous le comptoir doit presenter des qualit6s r6pertoriees dans los sp6cifications. Dans la plupart des cas, I'eau fournie par los municipalites repond a cos sp6cifications. L'eau de puits pout requerir un traitement--faites-la tester par un laboratoire d'analyses et suivez leurs recommandations pour traitement. ATTENTION Re dessus de I'_vier ou du comptoir. INSTALLATION DANS UN SOUS-SOL Si I'installation est effectu6e dans un sous-sol, menagez une Iongueur de conduite suffisante au cours de I'installation afin de faciliter •• Lorsque la duret6 de I'eau est sup6rieure a 10 grains (a un pH de 6,9), il est recommand6 d'utiliser un adoucisseur. Si un adoucisseur n'est pas utilis6, la dur6e de vie de la cartouche du systeme de filtration sera r6duite. I'entretien et d'assurer le remplacement filtres/membrane. Conduite et raccords suppl6mentaires sent necessaires. 33 des NOTE : Consultez la liste de pieces a la page 51 pour des pieces en option qui peuvent _tre n6cessaires pour une installation au sous-sol. Instructions d'installation ENSEMBLE D'OSMOSE INSTALLATION DE MONTAGE INVERSEE DU SYSTEME . Choisissez un emplacement sous I'evier pour monter le systeme. Cet emplacement dolt _tre facilement accessible, avec suffisamment d'espace libre entre le bas des cartouches de filtre et le plancher d'armoire ou le bas de I'armoire pour pouvoir enlever les cartouches de filtre. Laissez suffisamment d'espace de chaque c6te du systeme pour les raccords de tuyaux. 1. Enlevez les cartouches de post-filtre. de pr6-filtre et Tenez I'ensemble d'osmose inversee vers le haut le long de la surface du tour la ok vous voulez I'installer. Marquez I'emplacement des vis. II devrait y avoir au minimum 17 po (43 cm) de distance entre ces marques et le bas du plancher d'armoire. Emplacement _ATTENTION des vls : Ne mettez pas de poussiere ou de saletes dans I'endroit ou vous allez placer I'ensemble. Ne faites que marquer I'emplacement des trous de montage. 6. Pourenlever Pr_-filtre _ U_I_ "_-'_'U Pourenlever U_l_ Vissez les vis dans lemur, en laissant un espace de 3/16 po libre entre la t_te de vis et lemur (percez des trous de guidage si necessaire). • Postqiltre 7 po (17,8 . Enlevez le couvercle de I'ensemble d6verrouillant les quatre taquets sur le couvercle du systeme. 3. en cm)_3/16 po ,_0,5 cm) situes • Utilisez un tournevis & t_te plate pour aller de gauche a droite _ I'envers du systeme. i_ Vis Mur Emplacement 4. du tournevls Utilisez les ic6nes placees en bas du systeme pour bien placer votre tournevis. 7. Accrochez I'ensemble d'osmose invers6e sur les vis. Serrez ou desserrez les vis le cas echeant pour bien accrocher le systeme au mur. 8. Pour installer le couvercle, alignez les taquets situ6s I'avant du couvercle aux ouvertures du systeme. 9. Ouverture du syst_me _ Faitesclaquer le couvercle en place; les taquets se replient, en permettant au couvercle de bien tenir en place. 10. Enlevez la cartouche de membrane. 341 _ Membrane ,t[_ _! i_. Pour T"T L_J enlever Instructions ALIMENTATION d'installation D'EAU V_rifiez et conformez-vous aux codes de plomberie d'alimentation d'eau froide. A. INSTALLATION Utilisez le robinet PRI FI RENTIELLE d'alimentation 6vier (A) et le tuyau amovible 1. Consultez I'illustration terminer I'assemblage taille de votre robinet de robinet 3. 5. Serrez a la main I'adaptateur assemble (C) dans le robinet d'alimentation (A) conformement aux caract6ristiques de votre installation. Assurez-vous que le joint (G) soit en place avant I'assemblage final. Commencez I'installation a la main, puis finissez de serrer a la cle anglaise. Prenez bien soin de ne pas trop setter ou de ne pas fausser le filetage, car vous pouvez rendommager. 6. Rebranchez le tuyau du robinet sommet de I'adaptateur (C). ci-dessous pour en fonction de la d'alimentation (A). d'eau NOTE : Pour un tuyau rigide, consultez C. Installation optionnelle, a la page 36. Notez I'orientation de radaptateur (C) : Installation 3/8 po---Uadaptateur a extr6mit6 ronde (C) se branche au robinet d'alimentation (A). Installation 1/2 po--L'adaptateur a extr6mit6 ronde (C) se branche au raccord (D), puis au tuyau existant de robinet (B). Pour la plomberie de 3/8 po Pour la plomberie de 1/2 po robinet (non m compris) Raccord _1_ de (C) @ Adaptateur _ (8} Tuyau de robinet (non / [_ co_ris) _ _ Raccord _) Joint V \ _(C) 2,° t__ _ (F) Robinet (A) Robinet d'a{irnentqation d'eau froide (non compris) d'entr_e _ (B) au NOTE : Si vous devez enlever le robinet d'entr6e (F) pour votre installation, consultez E. Enlevement et r#installation du robinet d'entr6e, (B)Tuyau un raccord Assemblez I'adaptateur (C) et le raccord (D) comme I'indique I'illustration de gauche, conformement aux caract6ristiques de votre installation. Veillez ace que le joint (G) soit en place avant I'assemblage final. Commencez I'installation a la main, puis finissez de serrer a la cle anglaise. Prenez bien soin de ne pas trop setter ou de ne pas fausser le flletage, car vous pouvez rendommager. (B). D6vissez le tuyau flexible (B) du robinet d'alimentation (A) qui est branch6 au tuyau ascendant d'eau froide. puis installez 4. existant de votre Fermez le robinet d'alimentation froide (A) sous I'evier. . Iors de la planification Adaptateur a la page 37. 7. Coupez les liens metalliques des rouleaux de tuyaux, en prenant soin de ne pas endommager les tuyaux ou les pieces si vous utilisez un couteau tout usage. 8. Enlevez 1'6crou de 1/2 po (I) et la bague (H) de I'extr6mit6 du robinet d'entr6e. Utilisant le tuyau (raye jaune) fourni, placez I'ecrou (I) et la bague (H) sur le tuyau et installez dans le robinet d'entree (F) comme I'indique la figure de gauche. Serrez a la cle anglaise. Prenez bien soin de ne pas trop serrer ou de ne pas fausser le flletage, car vous pouvez rendommager. NOTE : Inspectez les extremites du tuyau avant I'installation pour vous assurer qu'il n'y ait pas d'imperfection et que I'extr6mit6 du tuyau soit bien coup6e a angle droit. Vous aurez peut-_tre besoin de recouper le tuyau. _ (A) Robinet d'alimentation d'eau froide (non compris) 35 Instructions ALIMENTATION d'installation D'EAU (suite) B. INSTALLATION OPTIONNELLE EFFECTUI E DANS UN DOMICILE B. INSTALLATION OPTIONNELLE EFFECTUI E DANS UN DOMICILE (suite) Lorsque les codes I'autorisent (Des pieces supplementaires sont necessaires) Raccordement optlonnel b la source d'alimentation d'eau (avec utitisation de la soupape b M;rier)* *Pour OD de 1/2 po ou tube m_tallique grandes dimensions. *Pour OD de 1/2 po ou tube m_=talliquede plus grandes dimensions. de plus Trou de 1/4 po NOTE : Les codes de I'_tat du Massachusetts exigent que I'installation soit effectuee par un plombier certifi_ et ne permettent pas I'utilisation de soupapes b _trier. Pour I'installation, utilisez le code 248-CMR du Commonwealth du Massachusetts. Ecrou (2)--non n_cessaire si ]es trous de la bride sont filet_s Fermez I'alimentation d'eau froide le robinet 3. la poignee d'alimentation dans _tre vlsibles i_ _'_"f/Soupa - X pe & _trier _t _)"_"''_ Poign6e Utilisez pour raccorder la conduite et C. INSTALLATION OPTIONNELLE AVEC TUYAU RIGIDE d'eau Pour installer avec un tuyau rigide entre le robinet d'entree et le robinet de 1'6vier. Option 1. , en le sens horaire. Ouvrez le robinet principal d'alimentation et plusieurs autres robinets de I'habitation afin de purger Fair du systeme. Fermez les robinets une fois que I'ecoulement d'eau est r6gulier. Montez la soupape dans Plusleurs filets doivent //Bride jp,_ compression sont raccord_es b la terre par I'interm_diaire de la plomberie. Pour vous mettre b I'abri de blessures graves ou de choc electrique fatal, utilisez une perceuse alimentee par batterie pour faire le trou. N'UTILISEZ PAS DE PERCEUSE I_LECTRIQUE. tournant que le joint est en place [_ -_£_ de la conduite Ecrou de/" DANGER : Beaucoup demaisons Fermez Joint--assurez-vous Rondelle Adaptateur montez la soupape _ 6trier comme I'exige le produit de votre choix. (Assurez-vous de suivre les instructions d'installation du fabricant). . "_ Bride Z -_-_ Une soupape b etrier est disponible aupr_s du service de pi_ces detach_es GE en composant le 1.800.626.2002, numero de rdf_rence WS15X10023. Les soupapes b etrier auto-per_ants ne sont pas recommand_s. 1. pr_-perc_ 1 Enlevez le tuyau du robinet et le robinet de 1'6vier. Obtenez un tuyau flexible correspondant la taille de votre plomberie. 3. Installez 4. Retournez & la section A. Installation pref_rentielle, etape 4. Option le tuyau flexible. 2 1. Obtenez des bagues de compression qui conviennent au tuyau rigide. 2. Obtenez toute autre bague n6cessaire brancher les bagues de compression I'adaptateur. IepAs_ ppx°Cr_ (S NEvsE ERREZ) NOTE : L'adaptateur 1/2 poet un filetage _f_ , Joint en caoutchouc a un filetage int6rieur ext6rieur de 3/8 po. Enlevez le tuyau du robinet pour de d'alimentation. 4. Coupez le tuyau afin que sa Iongueur corresponde _ celle des bagues assemblees eta I'adaptateur. 5. Installez la bague de compression 6. Retournez b la section A. Installation pref_rentielle, etape 4. NOTE : Les pieces 36 d'alimentation n'accompagnent indiquees sur le tuyau. ci-dessus pas le produit. Instructions D. INSTALLATION OPTIONNELLE (des pi_ces suppldmentaires sont necessaires) Fermez I'alimentation d'eau froide. 1. , , 4, d'installation A DISTANCE E. ENLI_VEMENT ET RI_INSTALLATION DU ROBINET D'ENTREE (necessaire uniquement si vous devez enlever le robinet d'entree pour terminer I'etape 5 la page 39) Installez un raccord sur la conduite d'eau froide pour adaptation a une conduite de diam_tre ext_rieur de 1/4 po, conform_ment aux codes de plomberie. Une connexion typique est montr_e dans I'illustration ci-dessous. V_rifiez qu'un robinet d'alimentation d'eau est utilis& Enlevez le robinet d'entr_e (F) de I'adaptateur (C) en utilisant une cle anglaise sur le corps du robinet. Consultez I'illustration ci-dessous pour de plus amples d_tails. N'UTIBSEZ JAMAIS LA CLESUR L'ECROU HEXAGONAL SITUE A L'EXTREMITE DU ROBINET, CAR VOUS POUVEZ PROVOQUER UNE FUITE. 1, Si I'_quipement de filtration a osmose inversee doit etre install_ a plus de 1,8 m (6 pi) du robinet, remplacez le tuyau d'entree (raye jaune) par une conduite GE de 1/4 po plus long. Une conduite de I/4 po de 10 m (33 pi) est disponible aupres du service de pi_ces detachees GE au 1.800.626.2002, numero de r_ference WSO7X10018. NE SUBS TITUEZ PAS DE CONDUITE DE QUAUTE INCONNUE. (C) Adaptateur Si I'_quipement de filtration a osmose invers_e doit _tre install_ a plus de 1,8 m (6 pi) du robinet, remplacez le tuyau de sortie (ray_ bleu) par une conduite GE de 3/8 po plus long. Une conduite de 10 m (33 pi) est disponible aupres du service de pieces d_tach_es GE au 1.800.626.2002, numero de r_f_rence WS07X10019. Voir Installation du (F) Robinet , robinet, page 39 pour plus de details. NE SUBSTITUEZ PAS DE CONDUITE DE QUAUTI_ INCONNUE. 3. Branchement pr_f_rentiel b I'alimentation d'eau (utilisant une bague de compression) I Robinet _ _/_ Bague . (raye jaune) _ I'entr_e Vers I'appareil RO , Si vous utilisez des tubes de cuivre, NE les branchez PAS directement sur I'equipement de filtration par osmose inversee. Achetez un connecteur et utilisez une conduite jaune plus court fourni pour faire la connexion finale _ I'equipement de filtration par osmose inversee. N'utilisez pas de tube de cuivre pour brancher _ machine _ gla_ons ou au robinet. 37 Enlevez tout le chatterton d'etanch_it_ des filetages du robinet d'entr_e (F) et de I'adaptateur (C). Serrez a la main I'adaptateur assembl_ (C) dans le robinet d'alimentation (A) pour votre bonne taille d'installation. Assurez-vous que les joints (G) soient en place avant I'assemblage final, conform_ment a I'illustration de la page 39. Serrez a la cle anglaise. Prenez bien soin de ne pas trop serrer ou de ne pas fausser le flletage, car vous pouvez I'endommager. Utilisez le chatterton d'etanch_it_ fourni, en tournant le chatterton environ 9 lois autour du gros filetage sur le robinet d'entr_e (F), dans le sens des aiguilles d'une montre, comme I'indique la figure droite. 4, d'eau Insert (non inclus) _'_1'_ Tuyau d'eau _ froide d'alimentation d'entr_e Serrez a la main le robinet d'entr_e (F) dans I'adaptateur (C), puis finissez de serrer a la cle anglaise. N'UTIUSEZ JAMAIS LA CLE SUB L'ECROU HEXAGONAL SITUE A L'EXTREMITI_ DU ROBINET, CAR VOUS POUVEZ PROVOQUER UNE FUITE. Instructions ALIMENTATION d'installation D'EAU (suite) INSTALLATION DU TUYAU AU RI_SERVOIR ET AU ROBINET PROCI_DURE DE REMPLACEMENT DU RI_DUCTEUR DE DI_BIT (suite) Mesurez 3/4 po (19 mm) _ partir de chaque extr6mite de tuyau restante (extremite du tuyau et extr6mite du robinet) et marquez avec un crayon (verifiez que le tuyau soit bien rond, lisse, qu'il n'ait pas de coupure, d'ar_te vive ou de point faible, et que la coupure soit bien perpendiculaire). 1. Enlevez le tuyau de vidange en poussant vers le haut la virole du tuyau de vidange (1) avec une main tout en enlevant le 1, tuyau , INCORRECT % . Poussez fermement le tuyau dans chaque raccord du collecteur jusqu'_ ce que le tuyau soit align6 au col du manchon (si le tuyau est enleve, recoupez son extr6mit6, mesurez, marquez et r6inserez). Vous devez bien ins6rer le tuyau pour 6viter toute fuite. Pour enlever le tuyau, appuyez sur la virole rouge ou bleue et tenez appuy& "rirez sur le tuyau pour I'enlever. Virole rouge ou bleue (NE PAS ENLEVER) Ligne Ins6rez main. Apres avoir enleve le tuyau de vidange de la base du systeme, saisissez I'extremite du reducteur de debit et tirez le r6ducteur droit vers vous pour le faire sortir du tuyau*. Si le reducteur est difficile a enlever la main, utilisez des pinces pour saisir I'extremite du reducteur, pour I'enlever plus facilement du tuyau. *Dans certains cas, le r_ducteur peut sortir en gllssant du tuyau de vidange quand vous I'enlevez du col du tuyau de vidange. SI, apr_s avolr enleve le tuyau de vidange conform_ment _ I'etape 1, le r_ducteur n'est plus & I'extr_mit_ du tuyau, v_riflez le col du tuyau de vidange. Enlevez ]e r_ducteur du col et passez _ I'_tape _ , __/ _j _.Engagemen_.t_ 3/4 po (2) avec I'autre f d'inserti_ le tuyau de vidange - I Prenez un nouveau reducteur et mettez-le en place en le faisant glisser dans le tuyau de vidange. Faites-le p6netrer a la main. N'utilisez jamais de pinces pour le remettre en place. Assurez-vous de faire entrer completement le r6ducteur dans le tuyau. Si vous ne le faites pas, vous risquez d'obtenir un mauvais fonctionnement du systeme (19 mm) i d'osmose inversee. (Tuyau de 3/8 po) . Tirez 16gerement sur le tuyau assurer qu'il est bien scell& pour vous f 4, PROCI_DURE DE REMPLACEMENT DU RI_DUCTEUR DE DI_BIT Chaque lois que vous changez la cartouche d'osmose inversee, vous devez egalement changer le reducteur de debit dans le tuyau de vidange. Assurez-vous de bien vous avant de toucher laver les pieces internes les mains du systeme. 38 Refaites entrer le tuyau de vidange dans la base du systeme. Tirez un peu sur le tuyau pour vous assurer que la virole est bien engagee et tient bien au tuyau. 3. Instructions INSTALLATION MONTAGE d'installation DU ROBINET DE ROBINET 5. Assurez-vousque vous disposezd'un espacesuffisant sous 1'6vierpour faire les raccordements. ChoisissezI'un des endroits suivants pour I'installation du robinet : NOTE : Pour faciliter I'insertion, trempez les extremit6s des tuyaux dens de I'eau chaude pendant quelques minutes pour les assouplir. •Dans un trou d'6vier existant pour tuyau de pulv6dsation d'eau ou distdbuteur de savon liquide. 6. Positionnez la base (E) et le corps (B) ensemble. Assurez-vousque le joint torique et le joint d'++tanch6it++ sont en place_ la jonction de la base et du corps. La poign6e du robinet sera positionn++e_ 3 heures par rapport _ la base. 7. Glissezla rondelle frein sur la tige filet6e du robinet (B), puis vissez 1'6crouhexagonal (H)sur la tige. Vissezsur la moiti6 de la Iongueur environ vers le haut. •Dans un trou a percer dens le dessus de I'evier. •Dans un trou a percer dens le comptoir, _ c6te de I'++vier. NOTE : Assurez-vous que la basedu robinet s'adaptera sur la surface de la position s++lectionn++e pour assurer une bonne jonction du joint du robinet et de la surface. 1. 2. 3. 4. Poussezla conduite noire de 1/4et 3/8 po sur leur raccord cannel++respectif sur le corps (B). Si un per£age est n++cessaire, faites un trou de 1-1/4po de diam_tre+Assurez-vousque voussuivezla bonne proc_ure pour le percage de la porcelaineou de I'acier inoxydable.Vouspouvez avoirbesoinde m_ches specialesde perceuse.Consultezun plombierqualifi++ pour trouverla bonneproc_ure. NOTE : Si vous utilisez le robinet sur un ++vieren acier inoxydable, faites glisser une bague d'installation (M) avant la rondelle frein+ Enlevez le robinet, le joint torique (D), la basede robinet (E),le joint d'++tanch++ite du bas de la base (F), la rondelle frein (G), I'++crouhexagonal (H) et le disque de montage (I) de I'emballage. 8. VissezI'adaptateur de tuyau _ I'extr6mit6 bleue (K) de I'arri++refilet6e du corps (B). 9. Poussezle tuyau (ray++bleu) dens I'adaptateur. II dolt p++n++trer d'environ 3/4 po (2 cm). Tirez dessus pour vous assurer qu'il tient bien. 10. Passezla conduite et la tige vers le bas au travers du trou de 1-1/4po (3 cm). Faitespasser le tuyau de 3/8 po (ray++bleu), le tuyau de 1/4po (noir) (attach++au syst++med'osmose invers++e) et le tuyau de 3/8 po (noir) (compris dans I'emballage) par le trou de montage de I'++vierou du comptoir. Cette++tapepeut n++cessiter deux personnes pour I'assemblage.Consultez la section Installation optionnelle du tuyau de robinet par une personne la page 40. Acheminez les deux conduites noires vers le haut au travers du joint d'++tanch6it++ (F),de la basedu robinet (E) et du joint torique (D). 11. AbaissezI'ensemble de robinet en place dens le trou de montage et orientez-le en position finale. Placezle disque de montage (I) au-dessusde la rondelle frein (G) autour de I'arri_re du robinet. En tenant le disque de montage en place, serrez fort I'++crouhexagonal. Cette ++tapepeut n6cessiter deux personnes. Raccord Bec cannel_ _--_r,_ Raccord cannel6 ASSEMBLE de 3/8 P° "_'''" /I_L Corps robinet Disque montage de (I) _ de 1/4 p_, Bague d installation (M) Capuchon du (B) |_i / _ Poign_e Joint Tuyau vidangeee3/8"_ ______toriq ue ID) Base (El •,,r Joint 4 po(nolr) hexagonal r] "Adaptateur 4 n_c_; _ I _ _ ROndelle frein (G) Ecrou hexagonal Aeaptateur condulte H) de la (K) Tuyau dev+eange -- A['t de 1/4 po (nolr) "'_'_ \"_-._,,,,,% Tuyau de sortie de 3/8 po (ray6 bleu) (H) de la condulte (lecas+ch+ant) t _ H[_ kktL_ Rondelle frein (G) _:crou _ de "_'- (K) / ,',,,_i,,, NOTE : Pour faciliter les op++rationsd'entretien, maintenez la conduite suffisamment long de telle fa£on que le retrait du systeme de filtration par osmose invers++esitu++sous le comptoir demeure possible. Vers l'_gout De Vappamil De l'appareil OI ol 39 Instructions INSTALLATION d'installation DU ROBINET (suite) INSTALLATION OPTIONNELLE DU TUYAU DE ROBINET PAR UNE PERSONNE 1. INSTALLATION En partant sous I'evier, r6unissez le tuyau de vidange de 1/4 (noir), le tuyau de vidange de 3/8 po (noir) et le tuyau de sortie de 3/8 po (ray6 bleu) dans une main, avec les tuyaux de drainage se terminant a la m_me Iongueur et le tuyau de sortie d6passant d'environ 6 pouces. 1. Utilisez un petit tournevis & t_te plate ou une piece de monnaie pour enlever le tiroir & pile (A) du c6te de la base de robinet. 2. Installez une pile CR2032 de 3 volts (B), le c6te positif (+) vers le bas, dans le tiroir pile (A). Faites glisser le tiroir & pile dans la base de robinet (C) jusqu'a ce que le rebord du tiroir pile (A) soit align6 au c6t6 de la base. La lumiere bleue (D) clignote cinq lois, indiquant ainsi une bonne installation et une remise & zero du systeme. Si vous voulez recommencer la procedure de demarrage du systeme, enlevez la pile pendant 45 a 60 secondes. Le systeme 61ectronique dolt se d6charger entierement. Remettez ensuite la pile en place. 3. 4. 2. Entourez les trois tuyaux 6lastique. d'une DE LA PILE bande 5. La lumiere est normalement 6teinte. Apres 6 mois d'utilisation, la lumiere se remet clignoter toutes les 30 secondes, indiquant ainsi qu'il est temps de remplacer le filtre. NOTE : La lumiere bleue peut s'arr6ter de clignoter si on la laisse clignoter pendant Iongtemps. Pour assurer un bon fonctionnement, vous devez changer la pile chaque lois que vous changez le filtre. _w 3. Ins6rez un crayon ordinaire la bande 61astique. No 2 dans (D) Lumi_re. bleue 4. Faites tourner le crayon jusqu'a ce qu'il soit aligne aux tuyaux et poussez vers le haut par le trou de montage. Rel_chez votre prise sur le crayon. Les tuyaux demeurent en position pour un branchement plus facile du robinet. (C) Base du robinet 4O (B) Pile (A) Tiroir _ & pile Instructions RACCORDEMENTS V_rifiez et conformez-vous d'installation A LA CONDUITE aux codes de plomberie MISE EN GARDE : les configurations d'installation des soupapes _ _trier. NOTE : Si vous ne vous conformez du produit, et I'installateur devient occasionne par le syst_me. Les options du syst_me repr_sentent pas de syst_mes UNIQUEMENT comportant INSTALLATION PRI_FI_RENTIELLE : OPTION B - INSTALLATION D'UN SIPHON P A VENTILATION TRADITIONNELLE Acheminez DIRECTEMENT la conduite de vidange du systeme de filtration par osmose invers6e & un 6vent du sous-sol, en d6rivant I'espace d'air menage dans le robinet. L'installation de 1'6cart anti-retour est laiss6e la discr6tion de I'installateur. II est aussi possible de diriger la conduite de vidange sur un orifice d'evacuation du sol ou encore darts une baignoire sous reserve que I'espace d'air du sous-sol est respect& Des raccords sp6ciaux pour I'espace d'air sont disponibles pour le raccordement de la conduite a Yevent. de vidange par osmose ci-dessous N'utilisez pas _ ces instructions d'installation, vous annulez la garantie responsable de tout service, r_paration ou dommage INSTALLATION PRI_FI_RENTIELLE : OPTION A - INSTALLATION DU SYSTI_ME AU SOUS-SOL Conduite filtratlon Iors de la planification. d_crites homologuees. DE VIDANGE Installez sous 1'6vier un siphon P a ventilation traditionnelle, qui sera utilise uniquement pour le tuyau de vidange d'osmose inversee. Un siphon P a ventilation traditionnelle est un siphon P qui a sa propre ventilation. Attachez I'adaptateur de tuyau de vidange au siphon P, et serrez-le avec I'ecrou coulissant et la rondelle comme I'indique la figure. Le tuyau de vidange DOlT passer par I'espace d'air fourni par le robinet d'eau d'osmose invers6e. de Tuyaude 7 vldange .__ J7 d'osmose 1 mversee II faut conserver ecart anti*retour molns un d'au 1 po (2,5 cm) 41 _ [- _ "IT; Evacua !_!_:!_I_-.. I option Instructions RACCORDEMENTS d'installation A LA CONDUITE INSTALLATION PRI_FI_RENTIELLE : OPTION C - INSTALLATION D'UN SIPHON P A VENTILATION INTERNE AU molns A'I-rENTION: sivous uti,sez roptio. Tuyaude vidange d'osmose_ invers_e _%"_?'_'_'L It-_-l,J / _ ' _ D, vous risquez de boucher la tuyauterie en cas de mauvaises conditions. L'utilisateur doit I'inspecter et la nettoyer periodiquement. N'INSTALLEZ PAS LE TUYAU DE VIDANGE EN AVAL D'UN EVACUATEUR OU SUR UN TUYAU HORIZONTAL. Installez I'adaptateur de tuyau de vidange sous I'_vier comme I'indique la figure (pi_ces comprises). Vous devez installer la chicane en T indiquee pour emp_cher que le tuyau de vidange d'osmose inversee se bouche. Amenez le tuyau de vidange de I'_cart anti-retour _ I'adaptateur de tuyau de vidange, en vous assurant qu'il n'y air pas d'angle d'inclinaison, de boucle ou de point bas dans le tuyau. Vous devez aligner verticalement I'adaptateur de tuyau de vidange de mani_re _ ce que le branchement de tuyau soit orient_ vers le haut (le branchement de tuyau ne doit jamais baisser de moins de 45 o par rapport _ sa position verticale). Cette installation peut occasionner un petit bruit de vidange quand le systeme d'osmose inversee se recharge. Si cela se produit, placez simplement les bouchons de vidange d'_vier pour arr_ter le bruit. n ,por- 4 po (10 cm)'_ l-I r-I[-_ Ii JJ', I _ (suite) INSTALLATION SECONDAIRE : OPTION D - INSTALLATION D'UN ADAPTATEUR DE TUYAU DE VIDANGE Installez sous I'evier un siphon P _ ventilation interne, qui sera utilise uniquement pour le tuyau de vidange d'osmose inversee. Un siphon P _ ventilation interne est un siphon P qui partage une ventilation commune. Attachez I'adaptateur de tuyau de vidange au siphon P,et serrez-le avec I'_crou coulissant et la rondelle comme I'indique la figure. Le tuyau de vidange DOlT passer par I'espace d'air foumi par le robinet d'eau d'osmose invers_e. Placez le siphon P d'osmose inversee aussi haut que possible (au moins 4 po [10 cm] au-dessus de I'horizontale). 7 DE VIDANGE = , _- - --* Evacuateur en option Maximum 45 ° ___Tuya u de _' )Chicane I J(obllgatolre) t_vacuateur en option en T,L v [L_ _ _ _ vidange _ id_vOeS_eSe 0e tuya'u "avidange De I'_cart antl-retour robinet daptateur de Oe0 deuxi_me evier ou I'_vacuateur nge \ Le branchement du tuyau de vidange dolt _tre 180 ° oppos_ la chicane en T ou au tuyau existant figure Bonne orientation comme de I'adaptateur ]'indique de tuyau pteteur 42 la de vidange de u _ vldange Instructions d'installation RESERVOIR DE STOCKAGE ET DEMARRAGE DU SYSTEME INSTALLATION DE STOCKAGE DU RI_SERVOIR Enlevez le capuchon du reservoir. 1. 2. . protecteur Enroulez 2 ou 3 tours de chatterton d'6tancheite, dans le sens des aiguilles d'une montre, autour du filetage du reservoir. Installez PROCI_DURE DE MISE EN MARCHE DU SYSTEME ATTENTION du haut Chatterto_n d'approvisionnement _ d'_tanch_it_ le raccordement Poussez le tuyau de 3/8 po (ray6 rouge) du systeme d'osmose invers6e dans le raccordement du reservoir installez votre syst_me dans une construction neuve, assurez-vous de bien purger la plomberie de la maison avant d'ouvrir le robinet poussoir sur le raccordement filet6 du r6servoir comme I'indique la figure. 4. •• Si vous R_servoir de st0ckage 1. Verifiez que tous les raccords soient bien mis. 2. Ouvrez le robinet 3. Verifiez qu'il n'y ait pas de fuite aux points de raccordement. 4. Suivez les procedures la page 45. 5. Apres avoir termin6 I'aseptisation, remettez le pre-filtre, le post-filtre et les cartouches d'osmose invers6e. 6. La membrane contient un agent de pr6servation comestible. Laissez le systeme remplir le r6servoir, videz-le ensuite completement quatre lois avant d'utiliser I'eau du systeme. 7. Verifiez a nouveau tous les points de raccords quelques jours plus tard, afin de vous assurer qu'il n'y ait pas de petites fuites. de stockage. 43 d'eau. de tuyaux d'approvisionnement d'eau. d'aseptisation Entretienet nettoyagedusysteme de filtration par osmosemversee. • f Procedure de remplacement d"osmose invers_e. du pr&filtre, Quand la hnni&re bleue de la base du robinet clignote, il est temps de remplacer le prd-filtre et le post-filtre. Cela se produit tousles 6 mois. L_sstlrez-vous de vous laver les mains avant de manipuler les pi&ces int_rieures du sysl_me. I_ Metlez la machine gtgla
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 84 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Tue Aug 14 20:48:52 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools