GS Instech GRS-1923R-SPR RF Repeater User Manual ATT E

GS Instruments Co., Ltd. RF Repeater ATT E

User manual

 FCC ID : U88-GRS-1923R-SPR   HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr Report No. :  HCTR1007FR27                                                                                                         1/1    ATTACHMENT E.   - USER MANUAL -
 Sprint User Manual 3G Indoor Repeater   1/23       3G Indoor Repeater  GRS-1923R-SPR User Manual          May, 2010 Version 0.1
 Sprint User Manual 3G Indoor Repeater   2/23 - INDEX - 1. SUMMARY................................................................................... 3 2. SYSTEM CONFIGURATION ......................................................... 4 2.1 GRS-1923R-SPR Service Organization.......................................................4 2.2 System Design and Operation....................................................................5 3. SPECIFICATIONS ..................................................................... 11 3.1 System Specifications(Applicable to both Uplink & Downlink)................11 3.2 Electrical and Environmental Specifications............................................12 3.3 Functions .................................................................................................12 4. SET UP...................................................................................... 15 4.1 System Set up..........................................................................................15 4.2 Troubleshooting.......................................................................................19
 Sprint User Manual 3G Indoor Repeater   3/23 1. SUMMARY  GRS-1923R-SPR is an Digital RF repeater, which improves PCS network.  GRS-1923R-SPR receives RF signal from BTS and transmits it to the blanked and shadowed area, thus providing and improving voice and image data services. GRS-1923R-SPR’s goal is to support BTS’s functions proportionately.  GRS-1923R-SPR communicates with BTS wirelessly, thus saving additional costs for its maintenance.  GRS-1923R-SPR consists of RF/IF part module, Digital Filter module, and I/O & Control module divisions, which are supplied with Alarm LED, thus providing quick and easy maintenance and troubleshooting of the repeater.  This manual describes in general structure of GRS-1923R-SPR, its application, maintenance and troubleshooting, installation and operation etc.         Abbreviation PCS : Personal Communication System RF: Radio Frequency BTS: Base Transceiver Station IF: Intermediate Frequency I/O : Input/Output
 Sprint User Manual 3G Indoor Repeater   4/23 2. System Configuration 2.1 GRS-1923R-SPR Service Organization GRS-1923R-SPR decreases blanked and shadowed areas and extends cell coverage by re-transmitting signal. The signal is received from BTS via Antenna directly, thus excluding additional expenses for signal transmission (like cabling). Service organization of CDMA In-building RF repeater is shown at the picture below. Donor Antenna is directed to BTS, and being divided at Service Antennas are installed in the building and parking place. Pass Loss should be taken into consideration while dividing and cabling.   <Pic.1> US PCS 1900 Service Organization
 Sprint User Manual 3G Indoor Repeater   5/23 2.2 System Design and Operation 2.2.1 System Design   <Pic.2> GRS-1923R-SPR Repeater
 Sprint User Manual 3G Indoor Repeater   6/23  <Pic.3> Internal Design  NO  DESCRIPTION ① CAVITY FILTER - (Frequency Filtering) ② CONVERTER MODULE - (Frequency Conversion) ③ PSU MODULE(RS-100-9) - (Converter, LED, NMS Power Supply) ④ I/O Board - (Input/Output Board) ⑤ NMS BOARD - (System Control Board) ⑥ DIGITAL FILTER - (Digital Filtering) ⑦ ETHERNET BOARD - (Web UI Board)
 Sprint User Manual 3G Indoor Repeater   7/23 ①②③④⑤⑥①②③④⑤⑥ <Pic.4> Outside Port Design  NO  DESCRIPTION ① DONOR ANT PORT  ② SERVER ANT PORT  ③ POWER SWITCH PORT  ④ AC POWER PORT  ⑤ CLI MONITOR PORT  ⑥ ETHERNET PORT
 Sprint User Manual 3G Indoor Repeater   8/23 2.2.2 Downlink Path Downlink and Uplink Gain Budgets have similar structure. In case of Downlink Path, RF signal is received from Donor Antenna, and through FWD  division, then the signal is transferred to IF division, where desirable Band is selected by Digital Filter. Selected Band is transferred to RF division again, and through FWD PAM, after that the signal is transmitted to User through Server Antenna. Two attenuators use for AGC compensation. AGC attenuation range is 40dB.  <Pic.5> Downlink Block Diagram
 Sprint User Manual 3G Indoor Repeater   9/23 2.2.3 Uplink Path Uplink Path is similar in structure to Downlink Path. In case of Uplink Path, RF signal is received from Server Antenna, and through RVS division, then the signal is transferred to IF division, where desirable Band is selected by Digital Filter. Selected Band is transferred to RF division again, and through RVS PAM, after that the signal is transmitted to BTS through Donor Antenna. Two attenuators use for ALC compensation. ALC attenuation range is 40dB.   <Pic.6> Uplink Block Diagram
 Sprint User Manual 3G Indoor Repeater   10/23 2.2.4 US PCS Frequency Selection  1930AB CDEF G1945 1950 1965  1970  1975  1990  1995 < Forward Band Structure >f (MHz) 1930AB CDEF G1945 1950 1965  1970  1975  1990  1995 < Forward Band Structure >f (MHz) 1850 AB CDEF G1865  1870 1885  1890  1895  1910  1915  f (MHz) < Reverse Band Structure >1850 AB CDEF G1865  1870 1885  1890  1895  1910  1915  f (MHz) < Reverse Band Structure >  <Pic.7> 1900MHz PCS Band Structure GRS-1923R-SPR has 5MHz, 10MHz, 15MHz, 20MHz Paths in IF division, so any of these bandwidths can be chosen for providing service. ITEM  BANDWIDTH  NOTE 5MHz 10MHz 15MHz 20MHz 5MHz + 5MHz 5MHz + 5MHz + 5MHz 10MHz + 5MHz Band Select 15MHz + 5MHz Any of these bandwidths from A to G can be chosen  Also, by adding Channel Select Function, it enables users to select bands sophisticatedly. Each band has 1.25MHz Bandwidth and if users select all the 15 bands, GRS-1923R-SPR can serve 18.75MHz bandwidth to users.
 Sprint User Manual 3G Indoor Repeater   11/23 3. SPECIFICATIONS  3.1 System Specifications(Applicable to both Uplink & Downlink) ITEM  SPECIFICATION  REMARK Transmit Power  23dBm ± 2.0dBm   Downlink  1930MHz ~ 1995MHz   Frequency Range  Uplink  1850MHz ~ 1915MHz   Gain Range  42dB ~ 82dB  DL/UL both Roll Off  ≥ 50dBc  @ F(edge)±1MHz VSWR  1.5 : 1   Delay 8us   @ Fc±885kHz ≥ 45dBc  marker to marker 29dB In Band Spurious Emission  @ Fc±1.98MHz ≥ -52dBc   marker to marker 36dB OUT Band Spurious Emission  < -13dBm   Flatness 3dB   5MHz 5+5MHz or 10MHz 5+5+5MHz or 10+5MHz or 15MHz Band Select 15+5MHz or 20MHz Non-contiguous Band (Maximum 3-band) Adding Channel Select Function Noise Figure  5dB @ Max Gain 12dB @ Min Gain   ALC Range  40dB, 1dB step   Frequency Stability  ±0.05ppm   Waveform Quality Factor  > 0.912   Output Power Variation over Temperature  ±2.0dB
 Sprint User Manual 3G Indoor Repeater   12/23 3.2 Electrical and Environmental Specifications ITEM  SPECIFICATION  REMARK Power & Consumption  100 ~ 240 VAC,60Hz   Connector Type  N-type female   Size 289X385X180   Weight  max 40 lbs   Reliability, MTBF  100,000 hours   Enclosure NEMA4   Operating Temperature  -10℃ ~ +50℃  Rel. Humidity  0% ~ 90%   Industry Standards  TIA-97, TIA-98, IS-98D, IS-2000   Regulatory Approvals  FCC, Part24 CDN-IC   Safety Approvals  UL1950 or Equiv      3.3 Functions ITEM  FUNCTIONS Gain Control  • Adjustable DL and UL Gain range 42~82dB • Display default Gain and current Gain function AGC (Auto Gain Control) • It always operates in Downlink AGC ON status • To maintain same Downlink output power despite flexible input signal strength • To add or subtract Attenuation level referring to AGC Power Limit level.• Used with the Automatic Setup (Auto Gain Setting) ALC (Auto Level Control) • To limit output power as far as default range • Used for DAS configuration and when oscillation/isolation is a concern • Automatic Gain decrement when output power of repeater is higher than default level • Automatic Gain recovery when output power of repeater is reduced
 Sprint User Manual 3G Indoor Repeater   13/23 • Shutdown when output power is higher than default level in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status AGS (Auto Gain Setting) • Operate when User control (Only system initialize) • Decrease attenuator value for 3dB from minimum gain • In case of attenuator value is from 0dB to 3dB when AGS ended - AGC on (DL) - Gain balance on - PAM on - Shut down on • In case of attenuator value is over 3dB when AGS ended - AGC off (ALC on) - Gain balance off - PAM on - Shutdown on Gain Balance • Downlink ATT is applied to Uplink during AGC state • Setting and maintenance of output level • Additional attenuation to ALC Level Band Select  • To select either 5MHz/10MHz/15MHz/20MHz Power Monitoring Function  • Monitoring repeater’s output level DL Input control  • Monitoring Donor ANT input power of DL Automatic Recovery  • When repeater is shutdown, it periodically recovers output power of repeater then monitors alarming Security  • Support HTTPS for Web Browser security • User authentication through User ID and Password Tem p era ture Monitoring • Monitoring temperature of repeater • Maximum and minimum set up is possible • Shutdown in over temperature • Automatic recovery after temperature becomes normal (Hysteresis 10degree)
 Sprint User Manual 3G Indoor Repeater   14/23 VSWR Monitoring  • Monitoring VSWR of Donor ANT Port (Every one and half minute) • Reporting VSWR Alarm and Shutdown when the rate is 3.5:1 IP address report via E-mail • When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address, reports to operator. DHCP Client  • Automatic IP assignment DHCP Server  • Server function for automatic IP assignment Web GUI  • Remote and local user browser support through Web Browser SNMP Agent  • NMS report via SNMPv2 Trap LED Display • LED displays power and operation status on front side of repeater system • Input and Output signal levels are verified by LED bars
 Sprint User Manual 3G Indoor Repeater   15/23 4. SET UP  4.1 System Set up 4.1.1 Constitution (Based on 1 set) PARAMETER  ITEM  QUANTITY Major Accessory  US PCS 23dBm case  1 EA Additional Components Main power input cable Fixable screw Mountable brackets 1 EA 1 SET 1 EA User Manual  Manual  1 EA  4.1.2 Notice 1) System Power check: Major electricity is AC110V, therefore please input electricity after power verification. 2)  Input condition optimization: DL input condition is -59 ~ -19dBm. User should verify input condition of Donor ANT. 3) Isolation check between DONOR/SERVER ANT: Isolation condition of this equipment is 89dBc (Gain+7dB). User should check its condition before installation.   <Pic.8> MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
 Sprint User Manual 3G Indoor Repeater   16/23 4.1.3 System Set up 1) This equipment is basically wall mountable installation. 2) Once aforementioned process is done, open for service get ready. 3) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 4) System installation work is basically performed more than two people and should be careful for unexpected accident. 5) The socket-outlet shall be installed near the equipment and shall be easily accessible. 6)  Round terminals located on the side of a 0.75 mm2 (18 AWG) or more wires Using    permanently connected to earth.   <Pic.9> Case Mounts - Step 1
 Sprint User Manual 3G Indoor Repeater   17/23   <Pic.10> Case Mounts - Step 2   4.1.4 Open for Service 1) Check points before open a. Verification of system installation status - Electricity, In/out antenna, coaxial cable connection, equipment mounts status. b. Verification of system accessories - User should check whole necessary accessories.    c. Check receipt signal level - User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized. 2) Check points after open a. Check by external LED
 Sprint User Manual 3G Indoor Repeater   18/23 ① RUN: Green light ON (Off: Green light off) ② ALARM: Green light in normal status, Red light in alarming ③ SHUT DOWN: Green light in normal status, Red light in Shutdown status ④ Number of LED bar on front side of repeater will show input power signal level Less than -86dBm: LED 1 bar -85dBm ~ -70dBm: LED 2 bar -69dBm ~ -54dBm: LED 3 bar -53dBm ~ -41dBm: LED 4 bar More than -40dBm: LED 5 bar  ⑤ Number of LED bar on front side of repeater will show output power signal level Less than +5dBm: LED 1 bar +6dBm ~ +10dBm: LED 2 bar +11dBm ~ +15dBm: LED 3 bar +16dBm ~ +20dBm: LED 4 bar More than +21dBm: LED 5 bar   <Pic.11> Front LED   b. Verification of operation status - User should verify following status with Output monitoring terminal, which is provided by Spectrum Analyzer - Output power generation status, system spurious emission characteristics.
 Sprint User Manual 3G Indoor Repeater   19/23 c. Verification of signal quality and strength in service area - User should verify signal strength and quality of in-service coverage area by using cell phone or other measuring device. d. Verification of upper-level NMS operation status   4.2 Troubleshooting In case of abnormal operation, technician should diagnose abnormality via remote access or directly connecting to repeater using Ethernet cable.  If technician is required to conduct repairs due to major alarm, repeater should first be powered off, and then technician should prepare the proper measurement equipment before trying to fix the problem.  In most cases of major repairs, GST will simply replace the unit and conduct repairs at the appropriate facility.  4.2.1 Necessary Testing and Measuring Equipment 1) RF Power Meter: 10Watt Max, 50ohm 2) Signal Generator: 3GHz 3) Spectrum Analyzer: 3GHz 4) Multi-Meter  4.2.2 Notice 1) Troubleshooting should be performed by a trained technician. 2) Parts that seem to be not used should not be disassembled.  3) While troubleshooting, technician should use attenuator to check RF Signal output.  4.2.3 Simple Troubleshooting Method 1) Verify LED Status, both on external LED’s as well as internal module LED’s - Normal operation: Green light on.  Alarming: Red LED on. 2) Technician should check external and internal connectors to ensure that all connections are tightly secure.  These connectors should be cleaned regularly. 3) If technician thinks there is a serious problem, call after sales team for over-the-phone technical support.  1-866-9-GST-USA (1-866-947-8872)
 Sprint User Manual 3G Indoor Repeater   20/23 4.2.4 Troubleshooting Guide Item  Check Point  Troubleshooting System input power range -Downlink: -59dBm ~ -19dBm -Uplink: -59dBm ~ -19dBm System gain  -Downlink: 42dB ~ 82dB -Uplink: 42dB ~ 82dB Output power at server port -Downlink: 23dBm ± 2dB -Uplink: 23dBm ± 2dB Check before system operation Check points before open for service -Please check quantity of all accessories with specification before you set up -Fit cable length in accordance with field condition -Set up 1900MHz CDMA Donor antenna to secure Isolation. (More than 89dBc) Check after system operation Check points after open for service Check following status; -Verify that the antennas are securely mounted and pointed in the correct directions -Connection status between antennas and RF cable-Verify that the Repeater is securely mounted -Proper AC power status -Grounding status of electrical circuit -Coaxial cable (RF) construction status -Connectors and combiners connection status -Cable connection status against leakage of water   4.2.5 Troubleshooting Guide Related to RF Symptom  Check Point  Troubleshooting When repeater does not work properly Check electricity cord connection status  -Re-plug in Adapter cord
 Sprint User Manual 3G Indoor Repeater   21/23 DL VSWR alarm Please Check following status; -Make sure Server Antenna Port is disconnected -Please reset Adapter upon completing Alarm  troubleshooting DL over-output alarm -Make sure output power is operating normally -Please Reset Adapter upon completing Alarm troubleshooting UL over-output alarm -Please make sure output level is operating normally-Please reset Adapter upon completing Alarm  troubleshooting Temperature alarm Check following status; -Setting level of maximum temperature limit -Temperature offset is normal or not -Circumstances of temperature -Please Reset Adapter upon completing Alarm  troubleshooting When in alarming RF off -Verify that the HPA’s are On -Please reset Adapter upon completing Alarm  troubleshooting Technician should verify category of alarm at the front side of repeater -When Red light on the Shutdown LED, technician should troubleshoot the alarm via Notebook computer -Technician should connect antenna with output port of repeater -Please make sure all connectors are fastened -Reconnect the connector -Change it if the connector is defective Check the input level  -Increase output power or check input change of BTS side When output power is  no longer problem Check gain of the unit  -If the Gain is different from normal level, please contact A/S team
 Sprint User Manual 3G Indoor Repeater   22/23 Cable connector loose -It is possible for connectors to get too tight and damage the equipment or throughput -Please contact installer or service provider upon verification Check input signal strength in the service area -Increase output power level of repeater by adjusting attenuation level If input signal strength is not a problem, please check delay of calling time -Increase output level of Uplink signal, then set to optimal level In case of dropped call or bad signal after set up Check RSSI signal strength -Contact network management team or service  provider Check connection fastened between antenna and cable (Signal wavelength should be flat and stable if technicians shake CABLE. If not, it is connection problem) -If connection is not proper, reconnect cable and connector and then check the output power again Input level change or    module overheating -Check input level from BTS side. -Check performance of each module (Diagnosed by A/S team) In case output Signal wavelength is not shown flat or looks like oscillation Please check VSWR of the cable is normal  -Change to normal Cable
 Sprint User Manual 3G Indoor Repeater   23/23 4.2.6 Troubleshooting Guide Related to NMS Symptom  Check Points  Troubleshooting Communication problem-In case of Ethernet, verify IP addressing, DHCP function, and that cookies are deleted -Verify that a crossover Ethernet cable is being usedCLI connection, cable     status check -Make sure 1:1 connection -Follow instructions in the installation guide for this connection procedure Link Fail CLI connection Check by USB to serial cable -Please verify port number of PC communication -Please check cable connection status
   MPE Information ⓒ SAMSUNG Electronics Co., Ltd.    Warning: Exposure to Radio Frequency Radiation The radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna should not be less than 20cm during normal operation. The gain of the antenna is 2 dBi.   The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.