GS Instech GSTR-TRIT-SPR Tri-Band In-Building RF Repeater User Manual 1

GS Instruments Co., Ltd. Tri-Band In-Building RF Repeater 1

User Manual

FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr       ATTACHMENT E.   - USER MANUAL -                       Report No. :  HCT-R07-020                                                                                                         1/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 2    INFORMATION TO USER :  NOTE:  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.   CAUTION Changes or modifications not expressly approved  by the manufacturer responsible for compliance  could void the user's authority to operate the equipment             Report No. :  HCT-R07-020                                                                                                         2/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 3 - INDEX - 1. SUMMARY .................................................................................................................4 2. SYSTEM CONFIGURATION.....................................................................................6 2.1 Tri-band repeater service network configuration ................................................6 2.2 System Design and Operation......................................................................................8 3. ELECTRIC MATERIAL AND SPECIFICATIONS...................................................14 3.1 System Capacity..............................................................................................................14 3.2 System Material & Mechanical Specifications......................................................15 3.3 Electrical Specifications................................................................................................15 3.4 Functions............................................................................................................................16 4. SET UP .....................................................................................................................18 4.1 System Set up...................................................................................................................18 4.2 Troubleshooting...............................................................................................................22 5. WEB USER INTERFACE .........................................................................................23 5.1 Common set up (PCS, IDEN) ......................................................................................23 5.2 PCS Web UI.......................................................................................................................24 5.3 IDEN Web UI.....................................................................................................................30  Report No. :  HCT-R07-020                                                                                                         3/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 4 1. Summary  Tri-band In-building repeater is located in blanket / shadow area of insider of building to transmit Sprint/Nextel CDMA (PCS), iDEN800MHz, iDEN900MHz BTS signal simultaneously. Characteristics (CDMA) CDMA (PCS) Band: 80dB Gain with  +24dBm maximum output power iDEN Band: 65dB Gain with +25dBmmaximum output power. Bandwidth: Entire 1900MHz CDMA (PCS) frequency A Block to G Block (65MHz). Bandwidth selection functions per user’s situation. - 5MHz, 10MHz, 15MHz Block and contiguous 20MHz combination - Three of non contiguous 5MHz block combination - 10MHz, 15MHz Block could be divided by 5MHz-Sub block.  - Remote control via Web based user interface Characteristics (iDEN 800MHz) Bandwidth - Downlink 851MHz~869MHz, Uplink 806MHz~824MHz (18MHz Band) - Downlink 862MHz~869MHz, Uplink 817MHz~824MHz (7MHz Band) To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by 200KHz, 400KHz. (TX Edge only, not whole bandwidth). - IDEN800MHz, iDEN900MHz simultaneous service - Remote selection either 18MHz or 7MHz  - Downlink band-edge adjustable (SAW Filter select) Report No. :  HCT-R07-020                                                                                                         4/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 5Characteristics (Tri-Band) Basically system box is two combination types of iDEN and CDMA technologies. Functional modules are classified as below.  - 6-Plex and Hybrid Multiplex Cavity Filter to combine HyCDMA (PCS), iDEN 800MHz, iDEN 900MHz, Duplex input/output signal.  - LNA(Low Noise Amplifier),  - Gain Block to transmit output signal to PAM (Power Amplifier Module).  - Donor LNA, Server LNA Module, which include Divider / combiner for IF Module interface. - IF Converter Module (thee in CDMA side, one of each iDEN800MHz, iDEN900MHz side)  - PAM Module to amplify output power linearly in accordance with optimal repeater output power.  - Power Supply Unit  - Controller to monitor each module in repeater.  All modules in Tri-Band repeater are commonly compatible with CDMA and iDEN standalone box.  Abbreviation PAM:  POWER AMPLIFIER MODULE LNA:  LOW NOISE AMPLIFIER AGC: AUTO GAIN CONTROL ALC: AUTO LIMIT CONTROL   For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the  equipment and shall be easily accessible.  Ethernet Instruction “ This equipment is indoor use and all the communication wirings  are limited to inside of the building” or similar texts.  Replaceable batteries instruction CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONSReport No. :  HCT-R07-020                                                                                                         5/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 6 2. System Configuration  2.1 Tri-band repeater service network configuration The system’s operation range is from A Block to G Block (Total: 65MHz) and the system features - to set up 20MHz using 5MHz, 10MHz, 15MHz and contiguous ‘Block’ - to set up 3 non-contiguous 5MHz Block  - to set up Sub Block by 5MHz with 10MHz, 15MHz Block - Remote control through GUI This system is to provide iDEN800MHz and 900MHz simultaneously.  Available band selection a. 18MHz Band of Downlink 851MHz~869MHz, Uplink 806MHz~824MHz  b. 7MHz Band of Downlink 862MHz~869MHz, Uplink 817MHz~824MHz   can select the 18MHz Band of Downlink 851MHz~869MHz, Uplink 806MHz~824MHz and Downlink 862MHz~869MHz, 7MHz Band of Uplink 817MHz~824MHz on remote control. Also, high frequency edge in Downlink side could be reduced by 200 KHz or 400 KHz to attenuate adjacent band signal  - Simultaneous service of IDEN800MHz, iDEN900MHz - IDEN800MHz remote band selection either 18MHz/7MHz  Downlink band-edge shifting is available (SAW Filter select)  Report No. :  HCT-R07-020                                                                                                         6/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 7 <Pic.1> Tri-band In-building Repeater Service organization Report No. :  HCT-R07-020                                                                                                         7/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 82.2 System Design and Operation 2.2.1 System design  NO.  PART  NO.  PART 1  SERVICE CAVITY MODULE  12  iDEN FWD LAN MODULE 2  DONOR CAVITY MODULE  13  iDEN NMS& I’O BOARD MODULE 3  5M IF CONVERTER MODULE  14  US PCS NMS& I’O BOARD MODULE 4  18M IF CONVERTER MODULE  15  US PCS WAVE MONITORING  MODULE5  7M IF CONVERTER MODULE  16  US PCS FWD  PAM 6  iDEN RVS LAN MODULE  17  US PCS RVS PAM Report No. :  HCT-R07-020                                                                                                         8/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 97  US PCS RVS LAN MODULE  18  iDEN WAVE MONITORING MODULE 8  20M IF CONVERTER MODULE  19  iDEN RVS PAM 9  15M IF CONVERTER MODULE  20  iDEN FWD PAM 10  10M IF CONVERTER MODULE  21  PSU MODULE 11  US PCS FWD LAN MODULE  22  HUB <Pic.2> Tri-band In-building Repeater internal design   NO.  PORT  NO.  PORT 1  SERVICE ANT PORT  6  DC POWER PORT 2  iDEN DONOR  ANT TERM  7  PCS MONITOR PORT 3  DONOR  ANT TERM  8  iDEN MONITOR PORT 4  CDMA DONOR  ANT TERM  9  ETHERNET HUB PORT 5  AC POWER PORT   Report No. :  HCT-R07-020                                                                                                         9/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 10<Pic.3> iDEN 25dBm PORT design 2.2.2 Downlink Path Tri-band In-building RF Repeater operates CDMA (PCS) and iDEN800MHz, iDEN900MHz. RF Module shares the modules used for CDMA (PCS) equipment and iDEN equipment and have differences in the configures of Donor ANT and Server ANT Port.  Tri-band In-building RF Repeater has separate 2 Donor ANT Port for aiming each BTS. Server Port for indoor is possible to one port. Therefore, Cavity Filter applied to Front End of Donor ANT Port consists of DPX for CDMA (PCS) and 4Plex for iDEN and Cavity Filter for Front End of Server ANT Port has 6-Plex which multiplexes all TX/RX in one path.  <Pic.4> Tri-Band In-building Repeater Downlink Block Diagram  2.2.3 Uplink Path  GST designed to use all same modules, which are used to stand alone unit, in Tri-Band unit. Report No. :  HCT-R07-020                                                                                                         10/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 11 <Pic.5> Tri-band In-building Repeater Uplink Block Diagram  2.2.4 Adjustable Band Edge functional circuit configuration In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is input via Donor ANT Outdoor. The most worried signal among them is Paging Signal. Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max. -15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band, 929MHz~932MHz bandwidth is possible for sufficient Rejection via SAW Filter, But  940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter because Band Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz Downlink. To prepare for this environment, Down Link of iDEN Repeater is designed to have additional Roll Off characteristic by decreasing band of SAW Filter in the station adjacent to paging signal, for it having the function of Adjust Band Edge that can decrease c of high frequency by 200 kHz, 400 kHz each. Report No. :  HCT-R07-020                                                                                                         11/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 12 <Pic.6> Achieving additional Roll Off via Adjust Band Edge  2.2.5 US PCS Frequency Selection  1930AB CDEF G1945 1950 1965  1970  1975  1990  1995 < Forward Band Structure >f (MHz) 1930B CDEF GA1945 1950 1965  1970  1975  1990  1995 < Forward Band Structure >f (MHz)  1850 AB CDEF G1865  1870 1885  1890  1895  1910  1915  f (MHz) < Reverse Band Structure >1850 B CDEF GA1865  1870 1885  1890  1895  1910  1915  f (MHz) < Reverse Band Structure >  <Pic.7> PCS Band Structure Setup of CDMA Block is formed by Switch and SAW Filter. If the operator set up the Block, Controller select the path of SAW Filter for disconnection of Switch and select the Local frequency to gain the preferable RF frequency modifying the data of PLL. The following show a circuit diagram for Band Select of CDMA. CDMA operates 1 to 3 Blocks at once using IF Converter Module containing the path of 2 SAW Filter in Downlink/ Uplink. Report No. :  HCT-R07-020                                                                                                         12/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 13 Configure of IF Converter for CDMA Block              Configure for one 5MHz Block        Configure for one 10MHz Block             Configure for one 15MHz Block                Configure for continuous 20MHz Block Report No. :  HCT-R07-020                                                                                                         13/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 14            Configure of separated 20MHz             Configure of 3 separated 5MHz   3. Electric Material and Specifications  3.1 System Capacity Item  Specification  Remark 851MHz ~ 869MHz  18MHz IDEN800 862MHz ~ 869MHz  7MHz Select IDEN900 935MHz ~ 940MHz  5MHz Down Link Frequency CDMA (PCS)  1930MHz ~ 1995MHz  65MHz 806MHz ~ 824MHz  18MHz IDEN800  817MHz ~ 824MHz  7MHz  Select IDEN900 896MHz ~ 901MHz  5MHz Up Link Frequency CDMA (PCS)  1850MHz ~ 1915MHz  65MHz Donor 0  CDMA TX / RX  Duplex Donor 1  IDEN TX / RX  4-Plex Port Server  CDMA / IDEN TX / RX  6-Plex Capacity OMNI   CDMA Channel Capacity  5MHz, 10MHz 15MHz, 20MHz Can select three separated block Simultaneously IDEN Select Bandwidth  18MHz / 7MHz  IDEN800MHz Report No. :  HCT-R07-020                                                                                                         14/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 15iDEN  +25dBm / 316mW Composite +22dBm / 158mW Per Single Band Output Power (ANT Port)  CDMA (PCS)  +24dBm / 250mW    3.2 System Material & Mechanical Specifications Item  Specification  Remark RF Connector  N-Type Female  Donor & Server ANT Port AC Power Connector  DC MS3102A-10SL (3Pin) SCK-16-2P (2Pin) MIL-C-5015 Type Circular Type AC Supply  AC 120V 60Hz 3.0A   Out Dimension  16.7*23*6.77  Inch Net Weight  29.5  kg Material Module AL6063S-T5 Cabinet AL5052P    Operation Temp eratur e -10  ~ ℃+50℃ Convection cooling   Humidity 5% ~ 95% Non-condensing Dust Resistance  TELCORDIA GR63-CORE   Vibration Resistance  1G, 10~150Hz 0.1 Octaves/min    3.3 Electrical Specifications Parameter  Specification  Remark Range  40dB ~ 80dB   Adjust Step  ±1.0dB   CDMA Gain Adjust Accuracy  ±0.5dB   Range  40dB ~ 65dB   Adjust Step  ±1.0dB   IDEN Gain Adjust Accuracy  ±0.5dB   CDMA  < 4.0μs   Propagation Delay  iDEN  < 5.0μs    Report No. :  HCT-R07-020                                                                                                         15/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 16F0±885kHz  <-45dBc  ∆marker: 29dB Spurious Emission  F0±1.98MHz  <-50dBc  ∆marker: 34dB Out Band Spurious Emission  <-13dBm  RBW: 30MHz @ CHOFFSET 25kHz  > 50dBc @ CHOFFSET 50kHz  > 55dBc @ CHOFFSET 500kHz  > 55dBc @ CHOFFSET 1MHz  > 55dBc Adjacent Channel Power @ CHOFFSET 2MHz  > 55dBc Degradation of 3dB for eight (8) iDEN carriers @ 869MHz  868.8MHz / 868.6MHz Adjust Band Edge  @ 940MHz  939.8MHz/ 939.6MHz  200kHz 2Step Flatness  <±1.25dB  800 ~ 900MHz  Return Loss / VSWR  > 14dB /<1.5: 1   CDMA <4.5dB @ Max gain <12dB @ Min gain   Up link Noise Figure iDEN <5dB @ Max gain <12dB @ Min gain   Wave form quality ( ρ )  > 0.912  CDMA (PCS) BER  iDEN ±1.0MHz  > 40dBc CDMA(PCS)  ±1.5MHz  > 50dBc Roll off IDEN ±1.0MHz  > 50dBc Test frequency measured from band edge Characteristic Impedance  50Ω   3.4 Functions Parameter  Specification Gain Control  • Adjustable DL and UL Gain range 40~65dB  • Display default Gain and current Gain function AGC Auto Gain Control • It always operates in Downlink AGC ON status • To maintain same Downlink output power despite flexible input signal strength.  • To add or subtract Attenuation level referring to AGC Power Limit level. Report No. :  HCT-R07-020                                                                                                         16/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 17ALC Auto Limit Control • To limit output power as far as default range  • Set up via GUI • Automatic Gain decrement when output power of repeater is higher than default level • Automatic Gain recovery when output power of repeater is reduced.  • Shutdown when output power is higher than default level in Minimum Gain• Automatic Recovery Algorithm conversion after Shutdown status Band Select  • To select either 18MHz or 7MHz in 800MHz Band Band Edge Adjust  • To shift Band edge of DL high frequency side by 200kHz, 400kHz step  Power Monitoring Function  • Monitoring repeater’s output level Oscillation Check • Isolation Check in initial set up or Reset  • Monitoring Oscillation comparing to minimum/maximum Noise Floor level • When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function.  • Shutdown repeater when Oscillation still goes in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status DL Input control   • Monitoring Donor ANT input power of DL Automatic Recovery  • When in repeater shutdown, it periodically recovers output power of repeater then monitors alarming Security  • Support HTTPS for Web Browser security • User authentication through User ID and Password Temperature control  • Monitoring temperature of repeater • Maximum and minimum set up is possible.  Shutdown in over temperature • Automatic recovery after temperature becomes normal. (Hysteresis 10degree) VSWR Monitoring • Monitoring VSWR of Donor ANT Port (Every one and half minute) • Reporting VSWR Alarm  and Shutdown when the rate is  3:1 • Automatic Recovery Algorithm conversion after Shutdown status IP address report via E-mail • When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address, reports to operator.  DHCP Client   • Automatic IP assignment DHCP Server   • Server function for automatic IP assignment Web GUI   • Remote and local user browser support through Web Browser SNMP Agent   • NMS report via SNMPv2 Trap Report No. :  HCT-R07-020                                                                                                         17/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 18LED Display  • LED displays power and operation status on front side of repeater system. • DL input and output signal level is verified by LED bar.   4. SET UP 4.1 System Set up 4.1.1 Constitution (based on 1 SET) Parameter  Item  Quantity Major accessory   TRI Case  1 EA Additional components  Main power input Cable Mountable Bracket Fixable Screw 1 EA 1 EA 1 SET User Manual  Manual  1 EA  4.1.2 Notice 1) System Power check: Major electricity is AC120V, therefore please input electricity after power verification.   <Pic.8> MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)  2) Input condition optimization: DL input condition of iDEN is -43 ~ -18dBm, and -56 ~ -16dBm for CDMA. User should verify input condition of Donor ANT 3)  Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 80dBc (Gain+15dB) in iDEN, and 95dBc (Gain+15dB) in US PCS. User should check its condition before installation. 4) This equipment is basically wall mountable installation.  Report No. :  HCT-R07-020                                                                                                         18/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 19 .  <Pic.9> Tri-band In-building Repeater Case mounts  Report No. :  HCT-R07-020                                                                                                         19/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 20<Pic.10> Tri-band In-building Repeater Case installation  4.1.3 System set up 1) Once aforementioned process is done, open for service get ready. 2) For grounding, there is a grounding terminal in main power supply side and the grounding  terminal on a site and unit should be connected same. 3) System installation work is basically performed more than two people and should be careful for unexpected accident.  4.1.4   Open for service 1) Check points before open  a. Verification of system installation status Electricity, In/out antenna, coaxial cable connection, equipment mounts status.   b. Verification of system accessories  User should check whole necessary accessories.   c. Check receipt signal level User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized.  2) Check points after open  a. Check by external LED  RUN: G①reen light ON (Off: Green light off)  ALARM: Green light in normal status, Red light in alarming②  SHUT DOWN: Green light in normal status, Red light in Shutdown  ③  iDEN ④  Number of LED bar on front side of repeater will show input signal level.  -43 dBm~38dBm: LED 1bar -37dBm~-33dBm: LED 2 bars -32dBm~-28dBm: LED 3 bars -27dBm~-23dBm: LED 4 bars Up than -22dBm: LED 5 bars Number of LED bar in output power side will show output power signal level.  +0dBm~+4dBm: LED 1bar +5dBm~+9dBm: LED 2bars +10dBm~+14dBm: LED 3bars +15dBm~+19dBm: LED 4bars Up than +20dBm: LED 5bars Report No. :  HCT-R07-020                                                                                                         20/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 21 CDMA:⑤  Number of LED bar on front side of repeater will show input signal level.  Less than -56dBm: LED 1bar -56dBm~-48dBm: LED 2bars -48dBm~-39dBm: LED 3 bars -39dBm~-31dBm: LED 4 bars -31dBm~-23dBm: LED 5 bars Number of LED bar in output power side will show output power signal level  Less than +6dBm: LED 1bar +6dBm~+12dBm: LED 2 bars +12dBm~+15dBm: LED 3 bars +15dBm~+18dBm: LED 4 bars +18dBm~+22dBm: LED 5 bars   <Pic.11> Tri-band In-building Repeater front LED   b. Verification via Debug Program   User should check operation status of repeater system via Debug Program.  c. Verification of operation status Use should verify following status with Output monitoring terminal, which is provided by  Spectrum Analyzer. - Output power generation status, system spurious emission characteristics.   d. Verification of signal quality and strength in service area User should verify signal strength and quality of in-service coverage area by using cell phone or other terminal.  e. Verification of upper-level NMS operation status Report No. :  HCT-R07-020                                                                                                         21/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 22 4.2 Troubleshooting  In case, abnormal operation is detected, user should check abnormal parts via remote accessible function or field debug, then conduct repair after turn it off.   4.2.1 Necessary Testing and Measuring equipment a. RF Power Meter: 10Watt Max, 50ohm b. Signal Generator: 3GHz c. Spectrum Analyzer: 3GHz d. Multi Meter  4.2.2 Notice a. Trouble shooting should be performed with drastic knowledge basis. b. Unsure parts should not be disassembled.  c. When in trouble shooting, technician should use attenuator to check output side.   4.2.3 Simple trouble shooting method a. In not important trouble, technician adjust the unit via remote accessible function or field debugging and should verify the reason of trouble.  b. Each Alarm LED included in each module should be verified trouble. Normal operation: Green light On.  Alarming: Red LED on  c. Technician should check external and internal connectors then fasten them. Those connectors should be cleaned up regularly.  d. If technician think this is heavy problem, call after sales team immediately.             Report No. :  HCT-R07-020                                                                                                         22/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-TEL:+82 31 639 8517    FAX:+82 31 639 8525 Report No. :  HCT-R07-020                                                                                                         23/37 23 5. WEB USER INTERFACE   5.1 Common set up (PCS, IDEN) 5.1.1 IP Address verification and Explorer setting (1) Start->Control Panel->Network Connections (2) Double-click Local Area Connections at LAN or High Speed internet  (3) Click Internet Protocol (TCP/IP) at General tap and click Properties. (4) Apply automatic IP address assignment at local connection    (5) Verify assigned IP address at local connection.   TECHNOLOGIES CO., LTD. DO, 467-701, KOREA    www.hct.co.kr (Unless IP address is not assigned, please click repair.)
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 245.1.2 Explorer option setting     - Proceed step by step as indicated in below. All files and records should be removed.     - Set up mode will be displayed after (2) click.    - Please proceed along following set up mode screen shot.   5.2 PCS Web UI  5.2.1 Web UI connection    - Input desirable IP address.    - Default Use Name and Password for Web UI  is ‘admin’. Report No. :  HCT-R07-020                                                                                                         24/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 25 5.2.1 Link menu     - Following screen shot is located left-top side of main menu and those are linked to relative window.    5.2.2 Web UI control 5.2.2.1 Status    - Currently setting level check at this menu tap. Report No. :  HCT-R07-020                                                                                                         25/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 26  5.2.2.2 RF Configuration     - Setting level can be changed at this menu tap.    - (1) Level change    - (2) Click Apply button    5.2.2.3 Alarm Configuration   - (1) On/Off function for entire alarm report  Report No. :  HCT-R07-020                                                                                                         26/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 27   - (2) Alarm status    - (3) On/Off function for individual alarm category    - (4) Alarm SNMP Mapping    - User may set and change its level per it field condition and click apply button.     5.2.2.4 Communication Configuration     - This provides all necessary information related to network    - To provide relative information about DHCP and modem    Report No. :  HCT-R07-020                                                                                                         27/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 28 5.2.2.5 User Management     - Add and Remove user, Assigning accessibility     - (1) User Registration: Click Register after input required information     - (2) User Removal: Click Delete upon click of user name you wish to remove.     - (3) Super User: Accessible to all kinds of information path           Read/Write: Accessible to all kinds of information path except for User management path.          Read: Checking status only. No control     5.2.2.6 Logs     - All users’ access record will be saved as a log.    5.2.2.7 Sub System/Mailing List  Report No. :  HCT-R07-020                                                                                                         28/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 29   - Set up e-mail address the place you wish to receive alarm.   5.2.2.8 Troubleshooting   Following is a trouble shooting table, which is frequently occurred to repeater and treatment method.    5.2.2.9 Remote Software Upgrade  - Upload repeater operation program. Report No. :  HCT-R07-020                                                                                                         29/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 30 5.2.2.10 System Reset     - Reset repeater.   5.3 IDEN Web UI 5.3.1 Web UI connection - Input IP address, want to reach. - Default setting User Name and Password for Web UI is ‘admin’. Report No. :  HCT-R07-020                                                                                                         30/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 31  5.3.1.2 Link menu    Following screen shot is located left side of main menu and those are linked to relative window.    5.3.2 Web UI Control 5.3.2.1 Status     - Currently setting level check at this menu tap.  Report No. :  HCT-R07-020                                                                                                         31/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 32  5.3.2.2 RF Configuration     - Setting level can be changed at this menu tap.    - (1) Level change    - (2) Click Apply button    5.3.2.3 Alarm Configuration  Report No. :  HCT-R07-020                                                                                                         32/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 33   - (1) On/Off function for entire alarm report     - (2) Alarm status    - (3) On/Off function for individual alarm category    - (4) Alarm SNMP Mapping    - User may set and change its level per it field condition and click apply button.      5.3.2.4 Communication Configuration     - This provides all necessary information related to network    - To provide relative information about DHCP and modem  Report No. :  HCT-R07-020                                                                                                         33/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 34  5.3.2.5 User Management  - Add and Remove user, Assigning accessibility     (1) User Registration: Click Register after input required information     (2) User Removal: Click Delete upon click of user name you wish to remove.     (3) Super User: Accessible to all kinds of information path           Read/Write: Accessible to all kinds of information path except for User management path.          Read: Checking status only. No control      5.3.2.6 Logs  Report No. :  HCT-R07-020                                                                                                         34/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 35   - All users’ access record will be saved as a log.   5.3.2.7 Sub System/Mailing List     - Set up e-mail address, the place you wish to receive alarm   5.3.2.8. Troubleshooting    -  Following is a trouble shooting table, which is frequently occurred to repeater and treatment method.    Report No. :  HCT-R07-020                                                                                                         35/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 365.3.2.9 Remote Software Upgrade  - Upload repeater operation program   Report No. :  HCT-R07-020                                                                                                         36/37
FCC ID : U88GSTR-TRIT-SPR                                                                                          HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr 375.3.2.10 System Reset     - Reset repeater   Report No. :  HCT-R07-020                                                                                                         37/37

Navigation menu