GS Instech GSTR-TRIT-SPR Tri-Band In-Building RF Repeater User Manual 1
GS Instruments Co., Ltd. Tri-Band In-Building RF Repeater 1
User Manual
FCC ID : U88GSTR-TRIT-SPR ATTACHMENT E. - USER MANUAL - HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 1/37 FCC ID : U88GSTR-TRIT-SPR INFORMATION TO USER : NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 2/37 FCC ID : U88GSTR-TRIT-SPR - INDEX 1. SUMMARY .................................................................................................................4 2. SYSTEM CONFIGURATION .....................................................................................6 2.1 Tri-band repeater service network configuration ................................................6 2.2 System Design and Operation......................................................................................8 3. ELECTRIC MATERIAL AND SPECIFICATIONS ...................................................14 3.1 System Capacity ..............................................................................................................14 3.2 System Material & Mechanical Specifications......................................................15 3.3 Electrical Specifications................................................................................................15 3.4 Functions............................................................................................................................16 4. SET UP .....................................................................................................................18 4.1 System Set up...................................................................................................................18 4.2 Troubleshooting...............................................................................................................22 5. WEB USER INTERFACE .........................................................................................23 5.1 Common set up (PCS, IDEN) ......................................................................................23 5.2 PCS Web UI .......................................................................................................................24 5.3 IDEN Web UI.....................................................................................................................30 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 3/37 FCC ID : U88GSTR-TRIT-SPR 1. Summary Tri-band In-building repeater is located in blanket / shadow area of insider of building to transmit Sprint/Nextel CDMA (PCS), iDEN800MHz, iDEN900MHz BTS signal simultaneously. Characteristics (CDMA) CDMA (PCS) Band: 80dB Gain with +24dBm maximum output power iDEN Band: 65dB Gain with +25dBmmaximum output power. Bandwidth: Entire 1900MHz CDMA (PCS) frequency A Block to G Block (65MHz). Bandwidth selection functions per user’s situation. 5MHz, 10MHz, 15MHz Block and contiguous 20MHz combination Three of non contiguous 5MHz block combination 10MHz, 15MHz Block could be divided by 5MHz-Sub block. Remote control via Web based user interface Characteristics (iDEN 800MHz) Bandwidth Downlink 851MHz~869MHz, Uplink 806MHz~824MHz (18MHz Band) Downlink 862MHz~869MHz, Uplink 817MHz~824MHz (7MHz Band) To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by 200KHz, 400KHz. (TX Edge only, not whole bandwidth). IDEN800MHz, iDEN900MHz simultaneous service Remote selection either 18MHz or 7MHz Downlink band-edge adjustable (SAW Filter select) HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 4/37 FCC ID : U88GSTR-TRIT-SPR Characteristics (Tri-Band) Basically system box is two combination types of iDEN and CDMA technologies. Functional modules are classified as below. 6-Plex and Hybrid Multiplex Cavity Filter to combine HyCDMA (PCS), iDEN 800MHz, iDEN 900MHz, Duplex input/output signal. LNA(Low Noise Amplifier), Gain Block to transmit output signal to PAM (Power Amplifier Module). Donor LNA, Server LNA Module, which include Divider / combiner for IF Module interface. IF Converter Module (thee in CDMA side, one of each iDEN800MHz, iDEN900MHz side) PAM Module to amplify output power linearly in accordance with optimal repeater output power. Power Supply Unit Controller to monitor each module in repeater. All modules in Tri-Band repeater are commonly compatible with CDMA and iDEN standalone box. Abbreviation PAM: POWER AMPLIFIER MODULE LNA: LOW NOISE AMPLIFIER AGC: AUTO GAIN CONTROL ALC: AUTO LIMIT CONTROL For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible. Ethernet Instruction “ This equipment is indoor use and all the communication wirings are limited to inside of the building” or similar texts. Replaceable batteries instruction CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 5/37 FCC ID : U88GSTR-TRIT-SPR 2. System Configuration 2.1 Tri-band repeater service network configuration The system’s operation range is from A Block to G Block (Total: 65MHz) and the system features - to set up 20MHz using 5MHz, 10MHz, 15MHz and contiguous ‘Block’ - to set up 3 non-contiguous 5MHz Block - to set up Sub Block by 5MHz with 10MHz, 15MHz Block - Remote control through GUI This system is to provide iDEN800MHz and 900MHz simultaneously. Available band selection a. 18MHz Band of Downlink 851MHz~869MHz, Uplink 806MHz~824MHz b. 7MHz Band of Downlink 862MHz~869MHz, Uplink 817MHz~824MHz can select the 18MHz Band of Downlink 851MHz~869MHz, Uplink 806MHz~824MHz and Downlink 862MHz~869MHz, 7MHz Band of Uplink 817MHz~824MHz on remote control. Also, high frequency edge in Downlink side could be reduced by 200 KHz or 400 KHz to attenuate adjacent band signal Simultaneous service of IDEN800MHz, iDEN900MHz IDEN800MHz remote band selection either 18MHz/7MHz Downlink band-edge shifting is available (SAW Filter select) HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 6/37 FCC ID : U88GSTR-TRIT-SPRTri-band In-building Repeater Service organization HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 7/37 FCC ID : U88GSTR-TRIT-SPR 2.2 System Design and Operation 2.2.1 System design NO. PART NO. PART SERVICE CAVITY MODULE 12 iDEN FWD LAN MODULE DONOR CAVITY MODULE 13 iDEN NMS& I’O BOARD MODULE 5M IF CONVERTER MODULE 14 US PCS NMS& I’O BOARD MODULE 18M IF CONVERTER MODULE 15 US PCS WAVE MONITORING MODULE 7M IF CONVERTER MODULE 16 US PCS FWD PAM iDEN RVS LAN MODULE 17 US PCS RVS PAM HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 8/37 FCC ID : U88GSTR-TRIT-SPR US PCS RVS LAN MODULE 18 iDEN WAVE MONITORING MODULE 20M IF CONVERTER MODULE 19 iDEN RVS PAM 15M IF CONVERTER MODULE 20 iDEN FWD PAM 10 10M IF CONVERTER MODULE 21 PSU MODULE 11 US PCS FWD LAN MODULE 22 HUB Tri-band In-building Repeater internal design NO. PORT NO. PORT SERVICE ANT PORT DC POWER PORT iDEN DONOR ANT TERM PCS MONITOR PORT DONOR ANT TERM iDEN MONITOR PORT CDMA DONOR ANT TERM ETHERNET HUB PORT AC POWER PORT HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 9/37 FCC ID : U88GSTR-TRIT-SPR iDEN 25dBm PORT design 2.2.2 Downlink Path Tri-band In-building RF Repeater operates CDMA (PCS) and iDEN800MHz, iDEN900MHz. RF Module shares the modules used for CDMA (PCS) equipment and iDEN equipment and have differences in the configures of Donor ANT and Server ANT Port. Tri-band In-building RF Repeater has separate 2 Donor ANT Port for aiming each BTS. Server Port for indoor is possible to one port. Therefore, Cavity Filter applied to Front End of Donor ANT Port consists of DPX for CDMA (PCS) and 4Plex for iDEN and Cavity Filter for Front End of Server ANT Port has 6-Plex which multiplexes all TX/RX in one path. Tri-Band In-building Repeater Downlink Block Diagram 2.2.3 Uplink Path GST designed to use all same modules, which are used to stand alone unit, in Tri-Band unit. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 10 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 10/37 FCC ID : U88GSTR-TRIT-SPR Tri-band In-building Repeater Uplink Block Diagram 2.2.4 Adjustable Band Edge functional circuit configuration In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is input via Donor ANT Outdoor. The most worried signal among them is Paging Signal. Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max. -15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band, 929MHz~932MHz bandwidth is possible for sufficient Rejection via SAW Filter, But 940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter because Band Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz Downlink. To prepare for this environment, Down Link of iDEN Repeater is designed to have additional Roll Off characteristic by decreasing band of SAW Filter in the station adjacent to paging signal, for it having the function of Adjust Band Edge that can decrease c of high frequency by 200 kHz, 400 kHz each. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 11 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 11/37 FCC ID : U88GSTR-TRIT-SPR Achieving additional Roll Off via Adjust Band Edge 2.2.5 US PCS Frequency Selection 1930 1945 1950 1965 1970 1975 1990 1995 f (MHz) 1915 f (MHz) < Forward Band Structure > 1850 1865 1870 1885 1890 1895 1910 < Reverse Band Structure > PCS Band Structure Setup of CDMA Block is formed by Switch and SAW Filter. If the operator set up the Block, Controller select the path of SAW Filter for disconnection of Switch and select the Local frequency to gain the preferable RF frequency modifying the data of PLL. The following show a circuit diagram for Band Select of CDMA. CDMA operates 1 to 3 Blocks at once using IF Converter Module containing the path of 2 SAW Filter in Downlink/ Uplink. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 12 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 12/37 FCC ID : U88GSTR-TRIT-SPR Configure of IF Converter for CDMA Block Configure for one 5MHz Block Configure for one 15MHz Block Configure for one 10MHz Block Configure for continuous 20MHz Block HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 13 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 13/37 FCC ID : U88GSTR-TRIT-SPR Configure of separated 20MHz Configure of 3 separated 5MHz 3. Electric Material and Specifications 3.1 System Capacity Specification Item Down Link Frequency Frequency 851MHz ~ 869MHz 18MHz 862MHz ~ 869MHz 7MHz Select IDEN900 935MHz ~ 940MHz 5MHz CDMA (PCS) 1930MHz ~ 1995MHz 65MHz IDEN800 Up Link Port IDEN800 Remark 806MHz ~ 824MHz 18MHz 817MHz ~ 824MHz 7MHz Select IDEN900 896MHz ~ 901MHz 5MHz CDMA (PCS) 1850MHz ~ 1915MHz 65MHz Donor 0 CDMA TX / RX Duplex Donor 1 IDEN TX / RX 4-Plex Server CDMA / IDEN TX / RX 6-Plex Capacity CDMA Channel Capacity IDEN Select Bandwidth OMNI 5MHz, 10MHz 15MHz, 20MHz 18MHz / 7MHz Can select three separated block Simultaneously IDEN800MHz HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 14 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 14/37 FCC ID : U88GSTR-TRIT-SPR Output iDEN +25dBm / 316mW Composite CDMA (PCS) +24dBm / 250mW Power (ANT Port) +22dBm / 158mW Per Single Band 3.2 System Material & Mechanical Specifications Item Specification Remark RF Connector N-Type Female Donor & Server ANT Port Power AC MS3102A-10SL (3Pin) MIL-C-5015 Type Connector DC SCK-16-2P (2Pin) Circular Type AC Supply AC 120V 60Hz 3.0A Out Dimension 16.7*23*6.77 Inch Net Weight 29.5 kg Material Module AL6063S-T5 Cabinet Operation -10℃ ~ Temperature +50℃ AL5052P Convection cooling Humidity 5% ~ 95% Dust Resistance TELCORDIA GR63-CORE Non-condensing 1G, 10~150Hz Vibration Resistance 0.1 Octaves/min 3.3 Electrical Specifications Parameter Specification Range 40dB ~ 80dB Adjust Step ±1.0dB Adjust Accuracy ±0.5dB Range 40dB ~ 65dB Adjust Step ±1.0dB Adjust Accuracy ±0.5dB Propagation CDMA < 4.0μ s Delay iDEN < 5.0μ s CDMA Gain IDEN Gain Remark HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 15 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 15/37 FCC ID : U88GSTR-TRIT-SPR Spurious F0±885kHz <-45dBc ∆marker: 29dB Emission F0±1.98MHz <-50dBc ∆marker: 34dB Out Band Spurious Emission <-13dBm RBW: 30MHz @ CHOFFSET 25kHz > 50dBc Adjacent @ CHOFFSET 50kHz > 55dBc Degradation of 3dB Channel @ CHOFFSET 500kHz > 55dBc for eight (8) iDEN @ CHOFFSET 1MHz > 55dBc carriers @ CHOFFSET 2MHz > 55dBc Power Adjust @ 869MHz 868.8MHz / 868.6MHz Band Edge @ 940MHz 939.8MHz/ 939.6MHz Flatness <±1.25dB Return Loss / VSWR > 14dB /<1.5: 1 CDMA Up link Noise Figure iDEN Wave form quality ( ρ ) 800 ~ 900MHz <4.5dB @ Max gain <12dB @ Min gain <5dB @ Max gain <12dB @ Min gain > 0.912 BER Roll off 200kHz 2Step CDMA (PCS) iDEN CDMA ±1.0MHz > 40dBc Test frequency (PCS) ±1.5MHz > 50dBc measured from band IDEN ±1.0MHz > 50dBc edge Characteristic Impedance 50Ω 3.4 Functions Parameter Specification • Adjustable DL and UL Gain range 40~65dB Gain Control • Display default Gain and current Gain function • It always operates in Downlink AGC ON status AGC • To maintain same Downlink output power despite flexible input signal Auto Gain Control strength. • To add or subtract Attenuation level referring to AGC Power Limit level. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 16 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 16/37 FCC ID : U88GSTR-TRIT-SPR • To limit output power as far as default range • Set up via GUI • Automatic Gain decrement when output power of repeater is higher than ALC Auto Limit Control default level • Automatic Gain recovery when output power of repeater is reduced. • Shutdown when output power is higher than default level in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status Band Select • To select either 18MHz or 7MHz in 800MHz Band Band Edge Adjust Power Monitoring Function • To shift Band edge of DL high frequency side by 200kHz, 400kHz step • Monitoring repeater’s output level • Isolation Check in initial set up or Reset • Monitoring Oscillation comparing to minimum/maximum Noise Floor level Oscillation Check • When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function. • Shutdown repeater when Oscillation still goes in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status DL Input control Automatic Recovery • Monitoring Donor ANT input power of DL • When in repeater shutdown, it periodically recovers output power of repeater then monitors alarming • Support HTTPS for Web Browser security Security • User authentication through User ID and Password • Monitoring temperature of repeater Temperature • Maximum and minimum set up is possible. Shutdown in over temperature control • Automatic recovery after temperature becomes normal. (Hysteresis 10degree) • Monitoring VSWR of Donor ANT Port (Every one and half minute) VSWR Monitoring • Reporting VSWR Alarm and Shutdown when the rate is 3:1 • Automatic Recovery Algorithm conversion after Shutdown status IP address report via E-mail • When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address, reports to operator. DHCP Client • Automatic IP assignment DHCP Server • Server function for automatic IP assignment Web GUI SNMP Agent • Remote and local user browser support through Web Browser • NMS report via SNMPv2 Trap HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 17 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 17/37 FCC ID : U88GSTR-TRIT-SPR • LED displays power and operation status on front side of repeater system. LED Display • DL input and output signal level is verified by LED bar. 4. SET UP 4.1 System Set up 4.1.1 Constitution (based on 1 SET) Parameter Item Quantity Major accessory TRI Case 1 EA Additional components Main power input Cable 1 EA Mountable Bracket 1 EA Fixable Screw 1 SET Manual 1 EA User Manual 4.1.2 Notice 1) System Power check: Major electricity is AC120V, therefore please input electricity after power verification. MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug) 2) Input condition optimization: DL input condition of iDEN is -43 ~ -18dBm, and -56 ~ -16dBm for CDMA. User should verify input condition of Donor ANT 3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 80dBc (Gain+ 15dB) in iDEN, and 95dBc (Gain+15dB) in US PCS. User should check its condition before installation. 4) This equipment is basically wall mountable installation. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 18 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 18/37 FCC ID : U88GSTR-TRIT-SPR Tri-band In-building Repeater Case mounts HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 19 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 19/37 FCC ID : U88GSTR-TRIT-SPR Tri-band In-building Repeater Case installation 4.1.3 System set up 1) Once aforementioned process is done, open for service get ready. 2) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 3) System installation work is basically performed more than two people and should be careful for unexpected accident. 4.1.4 Open for service 1) Check points before open a. Verification of system installation status Electricity, In/out antenna, coaxial cable connection, equipment mounts status. b. Verification of system accessories User should check whole necessary accessories. c. Check receipt signal level User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized. 2) Check points after open a. Check by external LED ① RUN: Green light ON (Off: Green light off) ② ALARM: Green light in normal status, Red light in alarming ③ SHUT DOWN: Green light in normal status, Red light in Shutdown ④ iDEN Number of LED bar on front side of repeater will show input signal level. -43 dBm~38dBm: LED 1bar -37dBm~-33dBm: LED 2 bars -32dBm~-28dBm: LED 3 bars -27dBm~-23dBm: LED 4 bars Up than -22dBm: LED 5 bars Number of LED bar in output power side will show output power signal level. +0dBm~+4dBm: LED 1bar +5dBm~+9dBm: LED 2bars +10dBm~+14dBm: LED 3bars +15dBm~+19dBm: LED 4bars Up than +20dBm: LED 5bars HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 20 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 20/37 FCC ID : U88GSTR-TRIT-SPR ⑤ CDMA: Number of LED bar on front side of repeater will show input signal level. Less than -56dBm: LED 1bar -56dBm~-48dBm: LED 2bars -48dBm~-39dBm: LED 3 bars -39dBm~-31dBm: LED 4 bars -31dBm~-23dBm: LED 5 bars Number of LED bar in output power side will show output power signal level Less than +6dBm: LED 1bar +6dBm~+12dBm: LED 2 bars +12dBm~+15dBm: LED 3 bars +15dBm~+18dBm: LED 4 bars +18dBm~+22dBm: LED 5 bars Tri-band In-building Repeater front LED b. Verification via Debug Program User should check operation status of repeater system via Debug Program. c. Verification of operation status Use should verify following status with Output monitoring terminal, which is provided by Spectrum Analyzer. - Output power generation status, system spurious emission characteristics. d. Verification of signal quality and strength in service area User should verify signal strength and quality of in-service coverage area by using cell phone or other terminal. e. Verification of upper-level NMS operation status HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 21 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 21/37 FCC ID : U88GSTR-TRIT-SPR 4.2 Troubleshooting In case, abnormal operation is detected, user should check abnormal parts via remote accessible function or field debug, then conduct repair after turn it off. 4.2.1 Necessary Testing and Measuring equipment a. RF Power Meter: 10Watt Max, 50ohm b. Signal Generator: 3GHz c. Spectrum Analyzer: 3GHz d. Multi Meter 4.2.2 Notice a. Trouble shooting should be performed with drastic knowledge basis. b. Unsure parts should not be disassembled. c. When in trouble shooting, technician should use attenuator to check output side. 4.2.3 Simple trouble shooting method a. In not important trouble, technician adjust the unit via remote accessible function or field debugging and should verify the reason of trouble. b . Each A l a r m L E D included in each module should be verified trouble. Normal operation: Green light On. Alarming: Red LED on c. Technician should check external and internal connectors then fasten them. Those connectors should be cleaned up regularly. d. If technician think this is heavy problem, call after sales team immediately. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 22 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 22/37 FCC ID : U88GSTR-TRIT-SPR 5. WEB USER INTERFACE 5.1 Common set up (PCS, IDEN) 5.1.1 IP Address verification and Explorer setting (1) Start->Control Panel->Network Connections (2) Double-click Local Area Connections at LAN or High Speed internet (3) Click Internet Protocol (TCP/IP) at General tap and click Properties. (4) Apply automatic IP address assignment at local connection (5) Verify assigned IP address at local connection. (Unless IP address is not assigned, please click repair.) TECHNOLOGIES CO., LTD. HYUNDAI CALIBRATION & CERTIFICATION 23 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 23/37 FCC ID : U88GSTR-TRIT-SPR 5.1.2 Explorer option setting - Proceed step by step as indicated in below. All files and records should be removed. - Set up mode will be displayed after (2) click. - Please proceed along following set up mode screen shot. 5.2 PCS Web UI 5.2.1 Web UI connection - Input desirable IP address. - Default Use Name and Password for Web UI is ‘admin’. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 24 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 24/37 FCC ID : U88GSTR-TRIT-SPR 5.2.1 Link menu - Following screen shot is located left-top side of main menu and those are linked to relative window. 5.2.2 Web UI control 5.2.2.1 Status - Currently setting level check at this menu tap. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 25 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 25/37 FCC ID : U88GSTR-TRIT-SPR 5.2.2.2 RF Configuration - Setting level can be changed at this menu tap. - (1) Level change - (2) Click Apply button 5.2.2.3 Alarm Configuration - (1) On/Off function for entire alarm report HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 26 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 26/37 FCC ID : U88GSTR-TRIT-SPR - (2) Alarm status - (3) On/Off function for individual alarm category - (4) Alarm SNMP Mapping - User may set and change its level per it field condition and click apply button. 5.2.2.4 Communication Configuration - This provides all necessary information related to network - To provide relative information about DHCP and modem HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 27 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 27/37 FCC ID : U88GSTR-TRIT-SPR 5.2.2.5 User Management - Add and Remove user, Assigning accessibility - (1) User Registration: Click Register after input required information - (2) User Removal: Click Delete upon click of user name you wish to remove. - (3) Super User: Accessible to all kinds of information path Read/Write: Accessible to all kinds of information path except for User management path. Read: Checking status only. No control 5.2.2.6 Logs - All users’ access record will be saved as a log. 5.2.2.7 Sub System/Mailing List HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 28 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 28/37 FCC ID : U88GSTR-TRIT-SPR - Set up e-mail address the place you wish to receive alarm. 5.2.2.8 Troubleshooting Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod. 5.2.2.9 Remote Software Upgrade Upload repeater operation program. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 29 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 29/37 FCC ID : U88GSTR-TRIT-SPR 5.2.2.10 System Reset - Reset repeater. 5.3 IDEN Web UI 5.3.1 Web UI connection Input IP address, want to reach. Default setting User Name and Password for Web UI is ‘admin’. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 30 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 30/37 FCC ID : U88GSTR-TRIT-SPR 5.3.1.2 Link menu Following screen shot is located left side of main menu and those are linked to relative window. 5.3.2 Web UI Control 5.3.2.1 Status - Currently setting level check at this menu tap. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 31 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 31/37 FCC ID : U88GSTR-TRIT-SPR 5.3.2.2 RF Configuration - Setting level can be changed at this menu tap. - (1) Level change - (2) Click Apply button 5.3.2.3 Alarm Configuration HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 32 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 32/37 FCC ID : U88GSTR-TRIT-SPR - (1) On/Off function for entire alarm report - (2) Alarm status - (3) On/Off function for individual alarm category - (4) Alarm SNMP Mapping - User may set and change its level per it field condition and click apply button. 5.3.2.4 Communication Configuration - This provides all necessary information related to network - To provide relative information about DHCP and modem HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 33 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 33/37 FCC ID : U88GSTR-TRIT-SPR 5.3.2.5 User Management - Add and Remove user, Assigning accessibility (1) User Registration: Click Register after input required information (2) User Removal: Click Delete upon click of user name you wish to remove. (3) Super User: Accessible to all kinds of information path Read/Write: Accessible to all kinds of information path except for User management path. Read: Checking status only. No control 5.3.2.6 Logs HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 34 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 34/37 FCC ID : U88GSTR-TRIT-SPR - All users’ access record will be saved as a log. 5.3.2.7 Sub System/Mailing List - Set up e-mail address, the place you wish to receive alarm 5.3.2.8. Troubleshooting Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 35 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 35/37 FCC ID : U88GSTR-TRIT-SPR 5.3.2.9 Remote Software Upgrade Upload repeater operation program HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 36 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 36/37 FCC ID : U88GSTR-TRIT-SPR 5.3.2.10 System Reset - Reset repeater HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 37 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-020 37/37
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Company : 한국기술투자(주) Source Modified : D:20070621074107 Creator Tool : Word용 Acrobat PDFMaker 7.0.7 Modify Date : 2007:06:21 16:44:41+09:00 Create Date : 2007:06:21 16:42:13+09:00 Metadata Date : 2007:06:21 16:44:41+09:00 Document ID : uuid:65898fc7-04d5-47c3-b181-b0a5ed1e5b69 Instance ID : uuid:75fefda2-8766-4f5c-8a5a-012461eb44fd Version ID : 4 Format : application/pdf Title : 붙임서류1 Creator : 이 인영 Subject : Headline : Page Count : 37 Page Layout : OneColumn Author : 이 인영EXIF Metadata provided by EXIF.tools