GS Instech SC-2624AMP In-Building Repeater User Manual 1

GS Instruments Co., Ltd. In-Building Repeater 1

User manual

Download: GS Instech SC-2624AMP In-Building Repeater User Manual                           1
Mirror Download [FCC.gov]GS Instech SC-2624AMP In-Building Repeater User Manual                           1
Document ID1482732
Application IDJ/pMCrZ+3ZRQzTw7wo/R5Q==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize443.44kB (5543055 bits)
Date Submitted2011-06-14 00:00:00
Date Available2011-07-29 00:00:00
Creation Date2011-06-03 09:59:38
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2011-06-14 13:28:00
Document Title슬라이드 1
Document CreatorPowerPointìš© Acrobat PDFMaker 7.0.5
Document Author: SEC

Version 1.0 * May 2011
SpeedCell Repeater
INSTALLATION GUIDE
Ver. 1.0
G06$03')8635
GDR-89192630-SPR
Version 1.0 * May 2011
SpeedCell Repeater
G06$03')8635
Installation Guide Ver. 1.0
Version 1.0 * May 2011
Contents of Box
Contents
Picture
Quantity
SpeedCell Repeater System
Power Cord
5.9ft (1.8m)
1EA
Ethernet Cable
6.6ft (2m)
1EA
1EA
Lag Screw
1/2” x 2”
8EA
1EA
Data cable
for 2600 AMP and DFM 2
2EA
1EA
Ground Sems Screw
M4 x 8mm
8EA
1EA
Mounting Sems Screw
M6 x 10mm
12 EA
1EA
Mounting Bracket
Extension Mounting Bracket
13.7”(W) x 20.5”(H) x 2.85”(D),15 lbs
CD which contains
- User Manual
- Installation Guide
RF Cable Set
Front RF Cable 3EA, Top RF Cable
6EA, Reference Cable 5EA
Quantity
1EA
DFM Unit (1),(2)
2.8”(W) x 16.9”(H) x 10.7”(D), 9.9 lbs
23.2”(W) x 18.5”(H) x 2.75”(D), 23.5 lbs
Picture
Ground Cable
6.6ft (2m)
PSU Unit
4.3”(W) x 16.9”(H) x 10.7”(D) , 15 lbs
2600 AMP Unit
3.9”(W) x 16.9”(H) x 10.7”(D), 15.2 lbs
Contents
Version 1.0 * May 2011
This publication provides instruction for installing the SpeedCell repeaters.
The images for the User Interface in this publication may vary from the repeater’s depending on its S/W
Version.
Copyright
© 2011, GS Teletech, Inc.
All Rights Reserved
Printed in Republic of Korea
Revision History
Date
Version
05/2011
Version 1.0
Changes
Certification
UL/FCC: This equipment complies with UL and FCC
Version 1.0 * May 2011
Warnings and Hazards
WARNING! ELECTRIC SHOCK
Opening the BDA (bi-directional amplifier) could result in electric shock and may cause severe injury.
WARNING! EXPOSURE TO RF
Working with the repeater while in operation, may expose the technician to RF electromagnetic fields
that exceed FCC rules for human exposure. Visit the FCC website at http://www.fcc.gov/oet/rfsafety
to learn more about the effects of exposure to RF electromagnetic fields.
WARNING! DAMAGE TO EQUIPMENT
Operating the BDA with antennas in very close proximity facing each other could lead to severe damage to the repeater.
RF EXPOSURE & ANTENNA PLACEMENT
Actual separation distance is determined upon gain of antenna used.
Please maintain a minimum safe distance of at least 8inch while operating near the donor and the server antennas. Also,
the donor antenna needs to be mounted outdoors on a permanent structure.
WARRANTY
Opening or tampering the BDA will void all warranties.
CAUTION: REPEATER SHOULD BE INSTALLED AS CLOSE AS POSSIBLE TO POWER SOURCE.
CAUTION: THIS REPEATER IS FOR INDOOR USE ONLY AND SHOULD BE LOCATED INSIDE OF BUILDING.
CAUTION: RISK OF EXPLOSION IF BATTERY ON CONTROLLER BOARD IS REPLACED WITH AN INCORRECT TYPE.
CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Version 1.0 * May 2011
Mounting Repeater
Wood-Framed Wall
• It is recommended to first attach a sheet of plywood to the wall. The sheet of plywood should be anchored to the studs in the wall.
• Using a pencil, mark the location for each of the mounting bracket's four mounting holes on the plywood.
• Place the mounting bracket over the four lag screws heads.
• Thread a lag screw at the positions marked in step 2.
Wood-Framed Wall
Mounting
Sems Screw
M6 x 10mm
 Mounting the Bracket
on a Wood-Framed Wall.
Extension Mounting
Bracket
Version 1.0 * May 2011
Hang and Grounding
• Hang the PSU unit to the mounting bracket.
• Locate the two Mounting Sems Screws (M6 x10mm) underneath the PSU unit. Tighten bolts until secure.
Mounting Sems Screw
M6 x 10mm
 Hanging the PSU Unit.
Version 1.0 * May 2011
Hang and Grounding
• Hang the rest of the units in the following order: 2600AMP, DFM 2.
• Locate the two Mounting Sems Screws (M6 x10mm) underneath each unit. Tighten bolts until secure.
CAUTION
Units must be hung in the following order only: 2600 AMP -> DFM 2
 Hanging the Rest of Units.
Version 1.0 * May 2011
Hang and Grounding
• Connect ground cables of each unit to the bracket using Ground Sems Screws (M4 x 8mm) as displayed at the picture below.
CAUTION
Ground Cable
Ground cables must be properly grounded to provide both EMI and voltage surge protection for the repeater.
 Grounding of the PSU, 1900 AMP, DFM 1, 800/900 AMP, 2600 AMP, DFM 2 Units.
Version 1.0 * May 2011
Hang and Grounding
• Locate the ground lug on the underside (or side) of the bracket.
• Crimp the ground cable to the ground lug.
• Route the free end of the ground cable to an approved (per local code or practice) ground source.
CAUTION
Ground cable must be properly grounded to provide both EMI and voltage surge protection for the repeater.
 Grounding the Bracket.
10
Version 1.0 * May 2011
Position Antenna
• After installing 2600MHz antennas the installer should make line of site.
• Customer specifications should be followed for positioning the antennas properly
Warning: In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the
antenna should not be less than 20cm during normal operation. The gain of the antenna is 12 dBi. .
 An installer is directing Donor Antenna to
nearby BTS to receive strong input signal.
11
Version 1.0 * May 2011
RF Cable Connections: Top of The Repeater
• Connect the 2600 Donor Antennas to their corresponding ports.
• Plug in four N(M) to N(M) type RF cables as demonstrated in the picture below.
D E F
CAUTION
Do not connect or disconnect cable from ANT port when power is ON.
800/900
DONOR AMP
DONOR ANT
2600
1900
1900
800/900
SERVER AMP
2600
1900
800/900
2600
SERVER ANT
Wi-Fi
SERVER ANT
SERVER ANT
CAUTION
CAUTION
Do not connect or disconnect cable
to/from ANT port when power is ON
Do not connect or disconnect cable
to/from ANT port when power is ON
SERVER ANT
CAUTION
Do not connect or disconnect cable
to/from ANT port when power is ON
DONOR ANT
CAUTION
Do not connect or disconnect cable
to/from ANT port when power is ON
DONOR ANT
CAUTION
DONOR ANT
Do not connect or disconnect cable
to/from ANT port when power is ON
CAUTION
Do not connect or disconnect cable
to/from ANT port when power is ON
 Top View of the Repeater.
12
Version 1.0 * May 2011
RF Cable Connections: Front Side
• Take out two SMA (M) to SMA (M) type RF cables.
• Please, pay attention to cable’s corresponding number and its color while connecting.
• Connect 2600 AMP and DFM 2 via Band 3.
PSU
DFM
800/900 AMP
2600 AMP
DFM
SpeedCell
SpeedCell
SpeedCell
SpeedCell
SpeedCell
DEBUG
SNMP
DO
AL
AR
SH
UT
RU
DEBUG
DEBUG
RUN
RUN
INPUT
INPUT
INPUT
OUTPUT
OUTPUT
ALARM
ALARM
OUTPUT
800
DEBUG
BAND
TX
BAND 1
AMP
DEBUG
DEBUG
DO
DFM 2
AL
AR
DFM 1
SH
UT
Reference
RU
SNMP
AMP 4
DO
AMP 3
AL
AR
AMP 2
SH
UT
AMP 1
RUN
ALARM
RU
RUN
1900 AMP
900
BAND
BAND 1
RX
RUN
RUN
ALARM
LAN
ALARM
WAN
BAND 2
BAND 2
BAND
Reference
GS Teletech Inc. Tech Support
1-866-9-GST-USA (toll free)
RUN
Bar Code
DFM
AMP
Bar Code
Bar Code
10M REF.
▼
10M REF.
▼
Bar Code
Bar Code
10M REF.
▼
Bar Code
10M REF.
▼
10M REF.
▼
 Front View of the Repeater.
13
Version 1.0 * May 2011
RF Cable Connections: Bottom of The Repeater
• Take out three SMA (M) to SMA (M) type RF cables.
• While connecting the PSU and the DFM units underneath, use referenced cable and pay attention to the labels. Plug them into
their corresponding outlets.
• User may choose either of the two SMA ports on the bottom of the PSU to connect to the DFM.
• User may choose any two of the four SMA ports on the bottom of the PSU to connect to amplifiers.
CAUTION
Please, pay attention while connecting PSU and DFM 1, PSU and
2600 AMP units. The repeater will not work if connection is inappropriate.
DFM
10M REF.
10M REF.
10M REF.
10M REF.
10M REF.
20 19 18 17 16
10 9
A1
A1
15 14 13 12 11
15 14 13 12 11
INTERFACE
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
20 19 18 17 16
8. GND
9. ID1
10. ID2
11~16. COM_GND
17~20. NC
A1. 5.5V
AMP INTERFACE
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
10. ID2
11~14. COM_GND
15~18. NC
19~22. COM_GND
23. 27.5V
24. 27.5V
25. 6.5V
AMP INTERFACE
10 9
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
10. ID2
11~14. COM_GND
15~18. NC
19~22. COM_GND
23. 27.5V
24. 27.5V
25. 6.5V
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
8. GND
9. ID1
10. ID2
11~16. COM_GND
17~20. NC
A1. 5.5V
INTERFACE
D E
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
INTERFACE
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
DFM INTERFACE
AMP INTERFACE
EXPAND FOR QUAD
AMP INTERFACE
AMP
10. ID2
11~14. COM_GND
15~18. NC
19~22. COM_GND
23. 27.5V
24. 27.5V
25. 6.5V
EXTRA
SNMP
INTERFACE
DC OUT
DFM INTERFACE
1.
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
A: AC
B: AC
C: F.G
C A
AMP INTERFACE
DFM
1: VCC
2: VCC
3: GND
4: GND
AMP
AMP INTERFACE
 Bottom View of the Repeater.
14
Version 1.0 * May 2011
Power Cord Connections
• Plug in the cables to PSU, 2600 AMP and DFM 2 as displayed at the picture below.
DFM
AMP
10M REF.
10M REF.
10M REF.
10M REF.
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
10. ID2
11~16. COM_GND
17~20. NC
A1. 5.5V
10. ID2
11~14. COM_GND
15~18. NC
19~22. COM_GND
23. 27.5V
24. 27.5V
25. 6.5V
10. ID2
11~14. COM_GND
15~18. NC
19~22. COM_GND
23. 27.5V
24. 27.5V
25. 6.5V
8. GND
9. ID1
10. ID2
11~16. COM_GND
17~20. NC
A1. 5.5V
A1
A1
15 14 13 12 11
15 14 13 12 11
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
INTERFACE
20 19 18 17 16
10 9
INTERFACE
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
AMP INTERFACE
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
AMP INTERFACE
20 19 18 17 16
10 9
INTERFACE
EXPAND FOR QUAD
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
10. ID2
11~14. COM_GND
15~18. NC
19~22. COM_GND
23. 27.5V
24. 27.5V
25. 6.5V
DFM INTERFACE
AMP INTERFACE
EXPAND FOR QUAD
AMP INTERFACE
AMP INTERFACE
10M REF.
1. RS485_P
2. RS485_N
3. GND
4. INSERT
5. RESET
6. NC
7. ID_RESERVE
8. GND
9. ID1
EXTRA
SNMP
INTERFACE
DC OUT
DFM INTERFACE
AMP INTERFACE
A: AC
B: AC
C: F.G
C A
AMP INTERFACE
DFM INTERFACE
1: VCC
2: VCC
3: GND
4: GND
These ports are used for an added
2600 MHz amplifier while extension
of the repeater.
AMP INTERFACE
 Bottom View of the Repeater.
15
Version 1.0 * May 2011
Connecting Power Cable and LED Light Verification
• Connect Power Cable
• Turn the switch “ON” on the left side of PSU.
System On
System Off
 AC Power Port Connection.
 ON/OFF Switch of SpeedCell Repeater.
• Turn the switch “ON” on the front side of PSU as displayed at the picture 12.
 Verification of LED Lights.
16
Version 1.0 * May 2011
LED Indicators
• The LED’s on the repeater will light up and should change to green as displayed at the picture below.
Tx and Rx LEDs will be blinking.
RUN LED : Green light ON.
ALARM LED : Green light is normal status, Red light is alarm status.
SHUT DOWN LED : Green light is normal status, Red light is shutdown status.
800/900
AMP
1900 AMP
DFM 1
2600 AMP
DFM 2
PSU
17
Version 1.0 * May 2011
Input Power Signal
• Please note the number of LED bars for input indicates signal strength level.
The tables below indicate the levels.
Number of LED bars on the front side of Repeater will show input signal level:
Less than ~ -86dBm
LED 1bar
-85dBm~-79dBm
LED 2 bars
-78dBm~-72dBm
LED 3 bars
-71dBm~-65dBm
LED 4 bars
More than -64dBm
LED 5 bars
 LED Bars Indication.
18
Version 1.0 * May 2011
Output Power Signal
• Please note the number of LED bars for output indicates signal strength level.
Number of LED bars on the front side of Repeater will show output signal level:
Less than ~ +5dBm
LED 1bar
+6dBm~+10dBm
LED 2 bars
+11dBm~+15dBm
LED 3 bars
+16dBm~+20dBm
LED 4 bars
More than +21dBm
LED 5 bars
LED Bars Indication. 19 Version 1.0 * May 2011 Web UI • LAN port is used for connection of laptop and repeater. • WAN 1 port is used for connection of repeater and wireless modem for remote access. • WAN 2 port is a redundancy port for remote access. Ethernet Port. 20 Version 1.0 * May 2011 Configuring Laptop to Connect to Repeater • Connect Ethernet crossover cable from the LAN port of the repeater to laptop. 1. Go to Local area connection. 2. Click ‘TCP/IP Properties’. 3. Choose ‘Obtain DNS server address automatically’. 21 Version 1.0 * May 2011 Login Screen Enter IP address by 192.168.2.1, you will be redirected to Login. Default User Name is ‘admin’, and default Password is ‘admin’. You may need to change password as described in the User Management section. Engineering Number and Site Name will initially be blank, you can input Engineering Number and Site Name as described in the Communications Configuration section. Repeater’s IP Address: 192.168.2.1 22 Version 1.0 * May 2011 Menu Select • After you log in, you can see ‘Menu Select’ page. • To setup the Repeater, click ‘Initial Installation’. • To go to menu list, click ‘Menu Page’. 23 Version 1.0 * May 2011 Setup Wizard • After you clicking on ‘Initial Installation’ the following screen will be displayed. • After typing the Latitude or Longitude numbers, press ‘Apply’ button. • User may skip this window if it is unnecessary. 24 Version 1.0 * May 2011 Setup Wizard ① Auto Configuration matches amplifier and DFM units automatically. ② Manual Configuration matches amplifier and DFM units manually. ① ② 25 Version 1.0 * May 2011 Setup Wizard • After clicking Auto Configuration, the screen below will be displayed. • It will take approximately one minute to finish the process. 26 Version 1.0 * May 2011 Setup Wizard Manual Setup Wizard for 2600MHz Band • User may choose bandwidth in this menu. After selecting bandwidth, click ‘Apply’ button. • Also User may skip this setting if it is not needed. 33 Version 1.0 * May 2011 Setup Wizard Manual Setup Wizard for 2600MHz Band (Choosing antenna) • After selecting an antenna type, click ‘Apply’ button. • Also User may skip this setting if it is not needed. Antenna Only (AGS Setting): Repeater sets up automatically (Auto Gain Setting, AGS) DAS (ALC D/L limit 7dBm Setting): Repeater operates with Active DAS DAS (ALC D/L limit Maximum Setting): Repeater operates with Passive DAS Not Use (HPA OFF): It disables this AMP unit 34 Version 1.0 * May 2011 List Menu • After clicking on ‘Main Page’, the ‘List Menu’ will be displayed. • User may check the Repeater status by clicking on ‘Status’. 35 Version 1.0 * May 2011 Status Menu • User may check status of amplifiers by clicking on any of them. 36 Version 1.0 * May 2011 RF Configuration Menu • Click the RF Configuration link. • Click AMP 1, AMP 2 or AMP 3 in order to go to the next window and change RF values. 44 Version 1.0 * May 2011 RF Configuration Menu FAQ’s • What is Auto Limit Control (ALC)? ALC is used for custom installations. If the repeater is having difficulties with isolation check, or if you want to “power down” the repeater ALC should be manually set. Attenuation may also be added for reducing power levels. ALC also provides optional U/L and D/L settings. - ALC controls the output power. - If you want to use the ALC function, Gain Balance Control should be turned off. - ALC will reduce max gain by the set value even if the input signal decreases. - ALC should be used if the repeater is connected to a DAS system. • What does the Shutdown ON/OFF control? - An internal wave-detection is checking the noise level. If the repeater cannot secure isolation it will go through a process of turning itself off, and turning back on while doing isolation checking. - If it is impossible for the repeater to secure isolation after 30 minutes, the repeater will shut down and stay shutdown. The items that may automatically require the repeater to shut down are: -> VSWR Alarm, Over Power Alarm, Over Input Alarm, and Temperature Alarm. • What is Gain Balance Control? - Gain Balance Control will always keep the UL and DL ATT the same while using AGC. GBC should always be left on to prevent damage to BTS while using AGC. - This is used for BTS to cell phone power control. 45 Version 1.0 * May 2011 Auto Gain Setting (AGS) Flow Chart 46 Version 1.0 * May 2011 RF Configuration Menu 2600MHz Band Selection Band Selection Algorithm ITEM BANDWIDTH NOTE Band Select 2 contiguous band is selectable AB , BC, CD, EF, FH, HG are selectable only Band Structure 2502 2518.5 2535 Blank 2551.5 2568 2624 2640.5 2657 2673.5 2690 (MHz) 49 Version 1.0 * May 2011 RF Configuration Menu • Click the RF Configuration link. Click AMP 1, AMP 2 or AMP 3 in order to go to the next window and change RF values. 50 Version 1.0 * May 2011 RF Configuration Menu 2600 AMP • User may change various RF values of the repeater on this page. • Changes will not take effect until you click “Apply” button. • This menu is where the installer will choose references for specific implementation. • In case that screen resolution is 1024 x 768, you may need to use scroll bar to view all. 55 Version 1.0 * May 2011 RF Configuration Menu 2600 AMP (continue of the page) • User may change various RF values of the repeater on this page. • Changes will not take effect until you click “Apply” button. • This menu is where the installer will choose references for specific implementation. • In case that screen resolution is 1024 x 768, you may need to use scroll bar to view all. 56 Version 1.0 * May 2011 Alarm Configuration Menu • Click ‘2600’ link to check alarm configuration of 2600AMP. • In case that Report Alarms is OFF, all alarms will be disabled. In case that Report Alarm is ON, you can enable and disable individual alarms. 59 Version 1.0 * May 2011 Communication Configuration Menu • Click on the ‘Communications Configuration’ link. • On this page you can change various values related to IP network. Because Web UI is based on IP network, incorrect configuration may make it impossible to connect to Web UI. In that case, you can troubleshoot as described in the Command Line Interface (CLI) section. • In case that screen resolution is 1024 x 768, you may need to use scroll bar to view all. 60 Version 1.0 * May 2011 Communication Configuration Menu • On this page you can change various values related to IP network. • Changes will not take effect until you click “Apply” button. • In case that screen resolution is 1024 x 768, you may need to use scroll bar to view all. In the line “Static” means connection using a fixed IP. “DHCP” means connection using DHCP, where If "DHCP Client" is "ON", then the repeater will run as a DHCP client. If "DHCP Client" is “OFF", then the repeater will get a Static IP. “DHCP” means connection using DHCP, where If "DHCP Server" is "ON", then the repeater will run as a DHCP server. 61 Version 1.0 * May 2011 User Management Menu • Click on the ‘User Management’ link. • On this page you can create and delete users, change passwords, and assign authorities to individual users. • Read will only all the user to view information on the menu pages, but cannot make any changes. • Read/Write Authority means that the user can view and change various values. • Super User is very similar to an Administrator account... CAUTION DO NOT DELETE ‘admin’. 62 Version 1.0 * May 2011 Alarm Logs • Click on the Alarm Logs link. • You can see a history of reported and reset Alarms. When an alarm is reported, the name and time of the alarm is displayed along with it’s current status. Red color means that the alarm is reported, and green color means that the alarm has returned to normal status. • After an Alarm condition lasts for the “Delay Alarm Reporting Minutes” set in RF Configuration page, the Alarm will be reported. 63 Version 1.0 * May 2011 Logs • Click on the Logs link. • You can see Logs regarding Web UI operation. Logs will maintain a history of up to 30 operations. • In case that screen resolution is 1024 x 768, you may need to use scroll bar to view all. 64 Version 1.0 * May 2011 Logs Continue of Logs page. • In case that screen resolution is 1024 x 768, you may need to use scroll bar to view all. 65 Version 1.0 * May 2011 Troubleshooting • Click on the Troubleshooting link. • You can refer to this page for GST's technical support. 66 Version 1.0 * May 2011 Software Upgrade • Click on the Remote Software Upgrade link. • In case that software upgrade is needed, you should use this page. • Click Browse button to select the file to upgrade from the laptop. • Choose the file to upgrade provided by GST. After you choose the file, you should click “upload” to send the file from your laptop to the Repeater. • Provided files are three, need to download each of them. - The files are, - ① SC_SNMP.MCU - ② SC_AMP.AMP - ③ SC_DFM.SDR SC_DFM.SDS CAUTION Be careful not to unplug the crossover Ethernet cable during software upgrade. 67 Version 1.0 * May 2011 Software Upgrade • After uploading is finished, verify that the File Name and the File Size is correct, then click ‘Upgrade System’ button. The lights on the repeater will be blinking and change color during upgrade which will take about two minutes for the upgrade to initialize. The lights will go back to normal when upgrade is done. 68 Version 1.0 * May 2011 System Reset • Click 'No' to return to the 'List' menu. • Click 'Yes' to reset the repeater via a soft-boot. This will not change any of the current settings 69 Version 1.0 * May 2011 System Reset • Click 'No' to return to the 'List' menu. • Click 'Yes' to reset the repeater via a soft-boot. This will not change any of the current settings. 70 Version 1.0 * May 2011 Factory Default Settings • Choose type of configuration to be restored to factory default settings. 71 Version 1.0 * May 2011 Factory Default Settings • This function will allow you to roll back to factory default settings. 72 Version 1.0 * May 2011 Configuration Transfer • Configuration Transfer function is for downloading and uploading set values of the repeater. 73 Version 1.0 * May 2011 Configuration Transfer: Download • Configuration Transfer Download Display. 74 Version 1.0 * May 2011 Configuration Transfer • Downloading process of set values. 75 Version 1.0 * May 2011 Configuration Transfer: Upload • Uploading process of set values. • Verify correct file is selected and click ‘Configuration Transfer’. 76 Version 1.0 * May 2011 Command Line Interface (CLI) • In case that you cannot reach Web UI, you should use CLI. You should connect the equipment’s CLI port to your laptop’s serial port using RS-232 cable. In case that your laptop does not have a serial port, you may need to use USB to Serial conversion cable. • To open HyperTerminal, click “Start”, then “Accessories”, then “Communications”, then “HyperTerminal”. CAUTION RS-232 cable or USB to Serial conversion cable is not provided with the equipment. After connection, you can access CLI using HyperTerminal. 77 Version 1.0 * May 2011 CLI • To verify and/or change port number, open “Control Panel”, then “System”, then “Hardware Tab”, then “Device Manager”. Double click “Ports”, then double click “Serial Cable” then click “Port Settings” tab, click “Advanced”, in the COM Port drop down menu, select “COM 1”, click “OK”. • After verification of port number, open HyperTerminal. • Enter CLI. • Click “OK”. 78 Version 1.0 * May 2011 CLI • In the “Connect using” drop-down menu, select “COM1”. • Click “OK”. 79 Version 1.0 * May 2011 CLI • “Bit per second” drop down menu, select “115200”. • “Flow control” drop down menu, select “None”. • Click “Apply”. • Click “OK”. 80 Version 1.0 * May 2011 CLI • Click “File”, choose “Properties” 81 Version 1.0 * May 2011 CLI • On ‘Settings’ tab. • ‘Emulation’ drop down menu, select ‘VT100’. • Click ‘OK’. 82 Version 1.0 * May 2011 CLI • In case that you cannot see login prompt, just press enter key several times. Login is ‘admin’ and Password is ‘admin’. 83 Version 1.0 * May 2011 CLI • In order to verify IP network configuration, you should type ‘communication’. • Press enter-key. 84 Version 1.0 * May 2011 CLI • In order to see values, you should type “get all”, and then press the enter-key. • Enter the following text: “set LAN_port_IP_address 192.168.2.1”, then press the enter-key. “set LAN_port_DHCP_Server ON”, then press the enter-key. “set WAN_port_IP_address 192.168.1.1”, then press the enter-key. “set WAN_port_DHCP_Client OFF”, then press the enter-key. “commit”, then press the enter-key. 85 Version 1.0 * May 2011 GST Technical Support Phone: Toll Free: 1-866-9 GST USA Phone: 913-469-6699 Write: GS Teletech Inc. 6900 College Boulevard, Suite 850, Overland Park, KS 66211, USA Product Information and Technical Assistance: www.gsteletechinc.com support@gsteletechinc.com Specifications and features of this installation guide are subject to change without notice or obligation. 86 Warning: Exposure to Radio Frequency Radiation The radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna should not be less than 20cm during normal operation. The gain of the antenna is 12 dBi. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. © 2010, GS Teletech, Inc. 66

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Keywords                        : 
Create Date                     : 2011:06:03 09:59:38+09:00
Creator Tool                    : PowerPoint용 Acrobat PDFMaker 7.0.5
Modify Date                     : 2011:06:14 13:28-07:00
Metadata Date                   : 2011:06:14 13:28-07:00
Format                          : application/pdf
Title                           : 슬라이드 1
Creator                         : SEC
Description                     : 
Document ID                     : uuid:5517e81d-42a7-4f53-93b7-aee8fcc4f1b6
Instance ID                     : uuid:6ea0b8d2-089d-4814-9baa-9fa3acefdf21
Manager                         : 
Company                         : Samsung Electronics
Comments                        : 
Category                        : 
Has XFA                         : No
Page Count                      : 66
Page Layout                     : SinglePage
Subject                         : 
Author                          : SEC
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U88-SC-2624AMP

Navigation menu