GTO Access Systems SGER GATE EDGE CONTROL UNIT User Manual

GTO Access Systems, LLC GATE EDGE CONTROL UNIT

User Manual

Download: GTO Access Systems SGER GATE EDGE CONTROL UNIT User Manual
Mirror Download [FCC.gov]GTO Access Systems SGER GATE EDGE CONTROL UNIT User Manual
Document ID3460325
Application IDV1VVF7aA9Pc6bzjB4DL3Dg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.93kB (611643 bits)
Date Submitted2017-07-11 00:00:00
Date Available2018-01-07 00:00:00
Creation Date2017-05-17 10:38:54
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-05-17 10:38:57
Document TitleUser Manual
Document CreatorAdobe InDesign CC 2017 (Macintosh)

PRINTERS INSTRUCTIONS
INSTR,INSTL,SGER SERIES - GTO P/N: 10016916 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 1 of 2
Description
PRO ACCESS
The SGER series of digital receivers are wireless radio controls designed for use
with automatic gate openers or garage door operators. The radio format provides
unparalleled security. Receivers and transmitters do not contain a typical “coding
switch”. Each transmitter is pre-set at the factory to a unique code. The receiver
is programmed by sending a signal to it from the transmitter(s) that are going to
be used with it. This stores the transmitters code into the receiver’s memory. The
receiver will retain its memory even without power. The receiver will activate only
from these “memorized” transmitters.
TM
SGER
DIGITAL GATE
RECEIVER
The SGER series has an “F” connector for attaching an antenna. The receiver is
supplied with a 9-inch local antenna, a three foot 75 ohm coaxial cable, and a
bulkhead connector for mounting the antenna outside the gate operator enclosure.
RECEIVER
3-FOOT
CABLE
CASE SCREWS
The receivers can operate from 10.5-30 volts DC and are normally powered from
the gate operator. The relay contact(s) are rated at 5 amps @ 32 volts AC/DC NEC
Class 2 circuit.
Installation Instructions
MOUNTING
HARDWARE
NOTE: SGER only works with SGET.
LOCAL
ANTENNA
Linear PRO Access • 3121 Hartsfield Road • Tallahassee, FL 32303
1.800.543.4283 • linearproaccess.com
STEP 1
Connect receiver relay output
Connect the appropriate channel wires (Ch. 1 - two gray wires)., (Ch. 2 - two
yellow wires) to the appropriate activation terminals on the gate operator.
STEP 2
Connect receiver to power
STEP 3
Connect the red power input wire to the radio power and the black wire to the
common terminal on the gate operator.
BULKHEAD
CONNECTOR
NUT
WASHER
Mount the receiver
Use the screws provided to mount the receiver within the operator housing. This
provides protection from the elements. Secure case with case screws.
MOUNT RECEIVER
INSIDE GATE
HOUSING
COMMON
10.5-30 VOLT DC
POWER
OPEN OBSTRUCTION
INPUT
SECURE CASE
CLOSED WITH TWO
SCREWS AT BOTTOM
OF CASE
COMMON
CLOSE OBSTRUCTION
INPUT
STEP 4
Connect antenna
STEP 5
Connect the coaxial cable to the “F” connector on the receiver. Drill a 3/8”
hole on the top of the operator housing for the bulkhead connector. Insert the
connector and secure it with the nut and lock washer. Connect the cable and
antenna to the bulkhead connector.
CONNECT COAXIAL
CABLE TO "F"
CONNECTOR
Open receiver case
To open the receiver case, remove the screws, squeeze sides of case and rotate
upward.
STEP 6a
SGER channel one learn switch
The pushbutton labeled LEARN 1 is used to program transmitters to channel one.
LEARN 1
CHANNEL ONE
PUSHBUTTON
SLIDE WEATHER
RESISTANT CAP
OVER CONNECTION
LEARN 1
USE THIS
PUSHBUTTON
TO ENTER A
TRANSMITTER
INTO CHANNEL
ONE
INSERT BULKHEAD
CONNECTOR THROUGH
OPERATOR HOUSING
SECURE CONNECTOR
TO HOUSING USING
WASHER AND NUT
CONNECT CABLE TO
BULKHEAD CONNECTOR
SQUEEZE BOTH SIDES AT TABS
AND TILT UPWARD
LEARN 2
PRINTERS INSTRUCTIONS
INSTR,INSTL,SGER SERIES - GTO P/N: 10016916 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 2 of 2
STEP 6b
Connect antenna
STEP 7
Program the receiver
The pushbutton labeled LEARN 2 is used to program transmitters to channel two. Momentarily press the receiver’s program button. The
red programming LED will light. The LED slowly blinks
for about 60 seconds. A transmitter must be entered
CHANNEL TWO
PUSHBUTTON
LEARN 2
while the LED is on. Press the desired learn button. The
LED will flicker indicating that the receiver has accepted
the transmitter and channel relay will toggle.
LEARN 1
PRESS THE LEARN
BUTTON FOR THE
DESIRED CHANNEL
(LEARN 1 or LEARN 2)
PRESS THE TRANSITTER
BUTTON ON THE CONTROL
BOARD
LEARN 2
LEARN 1
USE THIS
PUSHBUTTON
TO ENTER A
TRANSMITTER
INTO CHANNEL
TWO
NOTE: Be sure to press the receiver program button
for less than 2 seconds.
S2
THE LED WILL
LIGHT AND REMAIN
ON ABOUT FIVE
SECONDS
RECEIVER LED WILL FLICKER
AS TRANSMITTER IS ENTERED
INTO MEMORY
INFO 1
Erasing receiver memory
PRESS PROGRAM BUTTON FOR
FIVE SECONDS OR MORE
LEARN 2
Condition
NO
Low Battery
Open
YES
No resistance across TB1 and TB2 of SGET
No Ack 3
YES
SGET not able to send message
(dead or too far away)
Edge
Edge shorted
YES
LED WILL FLASH, COUNTING
THE TOTAL NUMBER OF
TRANSMITTERS PROGRAMMED.
THEN IT WILL BLINK ONCE
(CHANNEL ONE) OR TWICE
(CHANNEL TWO) AS THE
TRANSMITTERS ARE ERASED.
LIMITED WARRANTY
IMPORTANT
This Linear PRO Access (LPA) product is warranted against defects in material
and workmanship for twelve (12) months. The Warranty Expiration Date is labeled
on the product. This warranty extends only to wholesale customers who buy direct
from LPA or through LPA’s normal distribution channels. LPA does not warrant
this product to consumers. Consumers should inquire from their selling dealer as
to the nature of the dealer’s warranty, if any. There are no obligations or liabilities
on the part of LPA for consequential damages arising out of or in connection with
use or performance of this product or other indirect damages with respect to loss
of property, revenue, or profit, or cost of removal, installation, or re-installation.
All implied warranties, including implied warranties for merchantability and implied
warranties for fitness, are valid only until Warranty Expiration Date as labeled on
the product. This LPA Warranty is in lieu of all other warranties express or implied.
Linear PRO Access radio controls provide a reliable communications link and fill an
important need in portable wireless signaling. However, there are some limitations
which must be observed.
All products returned for warranty service require a Return Product Authorization
Number (RPA#). Contact LPA Technical Services at 1-800-543-1236 for an
RPA# and other important details
Alarm Fault?
Code
Low Batt 1
WARNING: Changes, modifications or adjustments not expressly approved by GTO
Access Systems, LLC could void the user’s authority to operate this equipment.
There Are No User Serviceable Parts.
DC Operator Wiring
GND
SENSE
Gate Edge
Controller
DC Operator
M2
WARNING: BE SURE GATE AREA IS
CLEAR OF OBSTRUCTIONS
LEARN 1
SGER
M1
TOUCH THE EDGE
SENSOR TO ENSURE
THE GATE OBSTRUCTS
Troubleshooting
Transmitters may be erased from the receiver’s memory by pressing and holding
the receiver’s program button until the LED blinks one time as the receiver’s
memory is erased. Then release the program button.
–
Test receiver
STEP 8
Be sure gate area is clear. Test the units by activating the gate and touching the
edge sensor to ensure the gate obstructs.
Closed
LEARN 1
Open
SENSE INPUT
NOTICE: This device complies with part 15 of the FCC rules and with Industry
Canada license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation
of the device
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de
l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
LEARN 2
SENSE POWER
3.3V
NOTE: For AC Operator install an AC
Sensor, and refer to the AC Sense
instructions book.
GND
Copyright© 2017 GTO Access Systems, LLC
Document Number: 10016916 REV A (05-15-17)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01
Create Date                     : 2017:05:17 10:38:54-04:00
Metadata Date                   : 2017:05:17 10:38:57-04:00
Modify Date                     : 2017:05:17 10:38:57-04:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Instance ID                     : uuid:8e53194f-7215-6741-b748-d708a5cec4b0
Original Document ID            : xmp.did:3512ecd6-0e72-46cc-ad64-44fb1365cdf3
Document ID                     : xmp.id:0c01da27-0b40-4f55-bb91-a3020c4d6353
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:fb75f739-51aa-403a-b5aa-aea6eaf2c992
Derived From Document ID        : xmp.did:f61e469c-f290-4383-83f1-2cf11b78b3fe
Derived From Original Document ID: xmp.did:3512ecd6-0e72-46cc-ad64-44fb1365cdf3
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Macintosh)
History Changed                 : /
History When                    : 2017:05:17 10:38:54-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 2017 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: I6H-SGER

Navigation menu