GUARDIAN DCRX01-CC Garage Door Opener User Manual L5112 T GU 615 150710
GUARDIAN SHANGHAI CORP. Garage Door Opener L5112 T GU 615 150710
GUARDIAN >
Users Manual
WARNING: To reduce the risk of injury to persons - Use this operator only with Residential Sectional Garage doors. Owner’s Manual ● Please read and understand this manual and safety instructions carefully before installation. ● The Opener WILL NOT CLOSE until the Photo Eye Safety System is properly installed and aligned. ● REGULARLY CHECK and TEST the Opener according to the safety label to ENSURE SAFE OPERATION. ● Retain this manual for future reference. Serial # __ __ __ __ __ __ __ Date Installed __ __ /__ __ /__ __ __ __ Located on the bar code label on top of your opener. The illustrations used in this instruction manual may differ from the actual product you have purchased. GDO Manual Revised: 03-17 GDOMU12A-4 Table of Contents Introduction Symbols and Icons Inventory Preparation / Door Balance Test Tools Required Assembly Assembling T-Rail Tension the Belt Installation Mounting Header Bracket Attaching Rail to Header Bracket and Mounting Door Bracket Mounting Opener to Ceiling Attaching Door Arms Installing Light and Emergency Release Handle 10 11 12 Wiring Wiring Instructions Connecting Photo Eye Safety System Connecting Door Control Console Connecting Power 13 14 15 16 Adjustment Aligning the Photo Eye Safety System Travel Limit Adjustment—I. UP Limit Travel Limit Adjustment—II. DOWN Limit Auto Force Adjustment Final Adjustment and Testing 16 17 18 19 20 Operation Programming Remote Controls *(OPTIONAL) Operating the Opener Maintenance Troubleshooting 21 22-23 24 24 Repair Parts and Service Installation and Accessory Parts Opener Assembly parts 25 26 Warranty 27 Symbols and Icons WARNING READ WARNINGS CAREFULLY to prevent SERIOUS INJURY or DEATH caused by electrocution or mechanical hazard. DO NOT connect power Please connect power Beeps from built-in buzzer of the opener * Optional Accessories Installation hardware shown in actual size Inventory Emergency Release Handle + Rope Photo Eye Safety System Opener Unit + Lamp Dome Light bulbs are not included) Door Control included in some models Door Control x2 Screw #6 x 1” x2 Remote Control 1-FDCC Drywall Anchor Push Button 3-FDCC Header Bracket Literature + Safety Labels Clevis Pin Long x1 5/16” x 2-1/4” Door Bracket Hitch Pin — Locking Clevis Pins x1 Door Arms INSTALLATION HARDWARE, LOCATED IN HARDWARE BAG (SHOWN IN ACTUAL SIZE 1:1) x2 x2 x2 Clevis Pin — Door arms 5/16” x 1” Lag Screw 5/16” x 2 1/2” — Header Bracket / Mounting Opener Lag Screw 1/4” x 1” — Door Bracket x2 x6 x4 Hitch Pin — Locking Clevis Pins x6 Bolt 5/16” -18 x 1” 5/16” Flange Nut — Door arms / Mounting Opener Lag Screw 1/4” x 1” — Photo Eye System T-rail Assembly x1 x1 Emergency Release Handle + Rope x4 x2 Lag Screw 5/16” x 1 5/8” — Door Bracket / Mounting Opener Hexagonal Screw 10 - 24 x 1/2” Flange Nut 1/4” -20 x1 Washer #10 x1 Spring Washer #10 Read and Follow These Important Safety Instructions IMPORTANT INSTALLATION INSTRUCTIONS WARNING — To reduce the risk of severe injury or death: 1. 2. 3. 4. 5. 6. 7. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. Install only on a properly balanced garage door. An improperly balanced door has the potential to inflict severe injury. Have a qualified service person make repairs to cables, spring assemblies, and other hardware before installing the opener. Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener. Where possible, install the door opener 7 feet or more above the floor. For products having an emergency release, mount the emergency release within reach, but at least 6 feet above the floor and avoiding contact with vehicles to avoid accidental release. Do not connect the opener to source of power until instructed to do so. Locate the control button: (a) within sight of door, (b) at a minimum height of 5 feet so small children are not able to reach it, and (c) away from all moving parts of the door. Install the Entrapment Warning Label next to the wall-mount control button in a prominent location. In case the adhesive does not adhere on the surface, the label should be attached to the surface by mechanical means. Entrapment Warning Label—Permanent attach next to wall-mounted control button 8. After installing the opener, the door must reverse when it contacts a 1-1/2-inch high object (or a 2 by 4 board laid flat) on the floor. IMPORTANT SAFETY INSTRUCTIONS WARNING — To reduce the risk of severe injury or death: 1. 2. 3. 4. 5. 6. 7. READ AND FOLLOW ALL INSTRUCTIONS. Never let children operate or play with door controls. Keep the remote control away from children. Always keep the moving door in sight and away from people and objects until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. Test door opener monthly. The garage door MUST reverse on contact with a 1-1/2-inch high object (or a 2 by 4 board laid flat) on the floor. After adjusting either the force or the limit of travel, retest the door opener. Failure to adjust the opener properly increases the risk of severe injury or death. Use the emergency release only when the door is closed. Use caution when using this release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death. KEEP GARAGE DOORS PROPERLY BALANCED. See owner’s manual. An improperly balanced door increases the risk of severe injury or death. Have a qualified service person make repairs to cables, spring assemblies, and other hardware. SAVE THESE INSTRUCTIONS. Preparation WARNING To prevent SERIOUS INJURY or DEATH: - Before beginning installation of the Opener please complete the following test to ensure that your door is balanced and in good working condition. - A poorly balanced door can cause serious injury and damage to the Opener. - Always have a qualified garage door service technician make any required adjustments and/or repairs to your door before proceeding with installation. - DISABLE ALL LOCKS and REMOVE ALL ROPES connected to the garage door BEFORE installing and/or operating the Opener. To prevent damage to the door and Opener: - DO NOT connect power until instructed. - Operate this Opener with AC 120V/60Hz power supply ONLY. BEFORE Beginning Installation: 1. Disable locks and remove all ropes connected to the garage door. Sectional Garage Door 2. Perform the following door test to ensure your door is balanced and in good working condition. To Test Your Garage Door 1. Raise and lower the door to check if there is any sticking or binding. 2. Check for loose hinges, damaged rollers, frayed cables and damaged or broken springs. 3. Lift the door approximately halfway and release. The door should stay at the point under proper spring tension. Call a qualified garage door service technician if your door binds, sticks or is unbalanced. Tools Required Level Tape Measure Drill, 3/16” and 5/16” Drill Bits Pencil Pliers Hack Saw Screwdriver Step Ladder Ratchet with 1/4” and 5/16” sockets Adjustable Wrench Rubber Mallet Hammer Assembling T-Rail ! WARNING To prevent SERIOUS INJURY: - DO NOT connect power until instructed. - Keep hands and fingers clear from sprocket during operation. - Wear gloves when installing chain/belt and cable. - Keep hands and fingers away from joints and possible sharp edges. CAUTION - DO NOT connect power until instructed. - To prevent INJURY, keep hands and fingers away from joints and possible sharp edges. - Wear gloves when installing chain/belt and cable. 1/4” Flange Nut x 4 Screw Spring Washer Washer Fig.1 To Assemble the Rail Align the pre-assembled T-rail on the top of opener in the direction as shown in Fig.1. Secure the T-rail to the opener firmly using 1/4” flange nut x 4. Final Step to T-Rail Installation Fasten the Screw(2) to the motor shaft with spring washer(3) and washer(4) in between. Tension the Belt / Chain WARNING To prevent SERIOUS INJURY: - DO NOT connect power until instructed. - Keep hands and fingers clear from sprocket during operation. - Wear gloves when installing chain/belt and cable. - Keep hands and fingers away from joints and possible sharp edges. Note: The chain or belt rail assembly comes pre-tensioned from the factory. Tighten until... Tension the Belt 1. Rotate the Shaft Linker towards the Trolley Shaft until the belt is slightly loose about 1/4” (6mm) above the base of the rail, referring to the actual-sized illustration below. Shaft-Linker Mid-point of rail assembly Top of Rail Actual Size Flange Nut Belt 1/4” (6mm) Base of Rail Tighten nut 2. Tighten the Flange Nut on Trolley Shaft against the -Linker. Shaft Remove the temporary screw driver holding the position of the trolley. Mounting Header Bracket WARNING To prevent SERIOUS INJURY: - DO NOT connect power until instructed. - The Header Bracket MUST be SECURELY fastened to the structural support on the mounting wall or ceiling, otherwise the door may not reverse when required. DO NOT install the Header Bracket over drywall. - Concrete anchors MUST be used when mounting the Header Bracket into masonry. - NEVER try to loosen, move or adjust garage door springs, cables, Pulleys, Brackets, or hardware, all of which are under EXTREME tension. - Contact a qualified garage door service technician if your door binds, sticks or is unbalanced. An unbalanced door might not reverse when required. To Install Header Bracket Header Wall Ceiling Header Bracket Door Spring 2” (5cm) clearance Highest Point of Door Travel Door Track Note: Installation procedures may vary according to door type. 1. While inside your garage, close the door and mark the vertical centerline of the garage door. Extend the line onto the header wall above the door spring. 2. Open the door to the highest point of travel. Mark a line on the header wall 2“ (5cm) above the highest point of travel. Note: DO NOT install the Header Bracket over drywall. In some installations, it may be necessary to install a 2x4 across two wall studs to create a suitable location for the Header Bracket. If installing into masonry, use concrete anchors (not provided). Door Wall-Mounting As shown in Fig.2, place the Header Bracket on the vertical centerline in direction shown. Mark and drill two 3/16” holes. Fasten the Header Bracket securely to a structural support using two 5/16” x 2-1/2” Lag Screws. Support block on floor Alternative Ceiling-Mounting Fig.1 Ceiling-mounting is suggested ONLY when clearance is minimal. Extend the vertical centerline onto the ceiling as shown in Fig.3. Center the Header Bracket on the vertical mark, no more than 6” (15cm) from the header wall. Mark and drill holes to fasten the Header Bracket securely to a structural support. MAX. 6” (15cm) UP Fin ine ntal L Horizo t of D st Poin Highe sh ed Ce ili n avel oor Tr OPENER Vertical Centerline Fig.2 (Wall-Mounting) Vertical Centerline Fig.3 (Ceiling-Mounting) Lag Screw 5/16” x 2-1/2” Attaching Rail to Header Bracket and Mounting Door Bracket CAUTION To prevent SERIOUS INJURY: - DO NOT connect power until instructed. - REINFORCEMENT is recommended for fiberglass, aluminum or lightweight steel garage doors BEFORE installing the door Bracket. Contact your door manufacturer for reinforcement options. To Attach the Opener to the Header Bracket 1. As shown in Fig.1, use the packaging carton as temporary support for the Opener. Place the Opener on carton to prevent damage. 2. Align the mounting hole on the header rail to the mounting hole on the Header Bracket. 3. Connect the Header Rail and the Door Bracket together with a 5/16” x 2-1/4” Clevis Pin and lock it in place with a Hitch Pin. To mount the Door Bracket Note: Some door reinforcement kits may provide direct attachment of the door arm to the reinforcement bracket. If you have a door reinforcement bracket with this option, skip this step and proceed with the next step “Mounting Opener to Ceiling”. Carton 1. Position the Door Bracket on the centerline of the door approximately 2” - 4” (5-10cm) below the top edge of the door, as shown in Fig.2. 2. Depending on the construction of your door, install using one of the steps shown if Fig. 3 below: For steel / lightweight doors with vertical steel reinforcements / factory reinforced. Hitch Pin Clevis Pin - 5/16” x 1-1/4” Fig.1 Top E ge of oor 2-4” (5-10cm) (a) Mark and drill two 3/16” holes. Make sure not to drill through the garage door. Secure the Door Bracket with two 1/4” x 1” Self-Threading Screws (provided) as shown in Fig.3(a). (b) Alternative installation: Drill two 5/16” holes through the door. Secure the Door Bracket using two 5/16” Bolts, lock washers and nuts (not provided) as shown in Fig.3(b). The length of bolts will depend on the thickness of your door. Wood door (c) Mark and drill two 5/16” holes through the garage door. Secure the Door Bracket using two 5/16” carriage bolts, washers and nuts (not provided) as shown in Fig.3(c). The length of bolts will depend on the thickness of your door. Note: DO NOT use Self-Threading Screws on a wood door. Vertical Centerline of Door UP Self-Threading Screw - 1/4” x 1” Fig.2 (a) (b) (c) Fig.3 Mounting Opener to Ceiling WARNING To prevent SERIOUS INJURY or DEATH: - DO NOT connect power until instructed. - Install the Opener at least 7 feet (2.13m) above the floor. - Fasten the Opener SECURELY to STRUCTURAL SUPPORTS of the garage to prevent falling. - If installing Brackets to masonry, concrete anchors (not provided) MUST be used. To Mount the Opener to Ceiling ppor al su Stru The three most common installation options are shown in Fig.1-3. Fig.1 shows mounting the Opener directly to structural support on the ceiling. Fig.2 and 3 show mounting on a finished ceiling, with heavy duty angle iron*. *(angle iron not included) Determine the mounting option that works best for your application and follow installation steps below: 1. Raise the Opener and rail assembly and temporarily place it on a stepladder. 2. Position the Opener and rail assembly so that it is aligned to the center line of the garage door. If the Header Bracket was mounted off center, align the Opener with the Header Bracket. 3. Measure the distance from each side of the Opener to the structural supports. 4. Cut both Hanging Brackets* to appropriate length Fig.1 Finished ceiling Angle Iron not provided *(Hanging Bracket not included) 5. Drill 3/16” holes in the structural supports. 6. Secure one end of each of the Hanging Brackets to the structural supports using 5/16” x1-5/8” Lag Screws (provided). 7. Secure the Opener to the Hanging Brackets and secure each side with a 5/16”-18x1” Bolt and Flange Nut (provided). 8. Move the door manually to check clearance between highest point of travel of the door and rail. If the door hits the rail, raise the Header Bracket or adjust the mounting of Opener. 9. Remove the ladder ONLY when the Opener is securely mounted to the structural supports. Bolt / Lock Washer / Nut not provided Fig.2 Finished ceiling Angle Iron not provided Fastening Hanging Brackets to structural supports Lag Screw 5/16” x 1-5/8” Securing Opener to Hanging Brackets Bolt / Lock Washer / Nut not provided Fig.3 10 5/6”Flange Nut Bolt 5/16” - 18x1” Attaching Door Arms ! WARNING To prevent SERIOUS INJURY: - DO NOT connect power until instructed. - Keep hands and fingers away from the sprocket during operation. - Wear gloves when installing chain/belt and cable. - Keep hands and fingers away from joints and possible sharp edges. NOTE: The straight door arm must be installed vertically to the door when door is at closed position. Straight Door Arm To Connect Door Arm Follow the steps shown in Fig. 1 1. Fasten the Straight Door Arm to the Trolley with a 5/16” - 1” Clevis Pin and lock it with a Hitch Pin. Curved Door Arm 2. Fasten the Curved Door Arm to the Door Bracket with 5/16” - 1”Clevis Pin and lock it with a Hitch Pin. 3. To connect the door arms together, choose two pairs of holes which are as far apart as possible. Fasten the arms using two 5/16” - 18 x 1” Bolts and Flange Nuts. Ceiling Ceiling Rail of Opener Rail of Opener <1-3/4”mm >1-3/4”mm Door Panel Door Panel Flange Nut Hitch Pin Bolt 5/16” - 18x1” Clevis Pin - 5/16” x 1” Fig.1 11 Installing Light and Emergency Release Handle WARNING To prevent SERIOUS INJURY or DEATH from electrocution: - Disconnect power cord before installing/replacing light bulb. To prevent possible OVERHEATING or damage to Opener: - Use ONLY A19 (E26) incandescent bulbs (100W max.). - DO NOT use short neck or specialty light bulbs. - DO NOT use halogen bulbs. To install light bulb as shown in Fig.1: 1. 100W Install a standard A19 (E26) 100 watt maximum light bulb. AX 2. Re-attach the Lamp Dome. To replace light bulb as shown in Fig.2: 1. Fig.1 Press the release buttons and detach it from the Opener. 2. Replace light bulb and reattach the lamp dome. Notice When replacing the light bulb, make sure the bulb on the Opener has cooled down to prevent injury. Fig. 2 WARNING To prevent SERIOUS INJURY or DEATH from a falling garage door: - In case of power failure or door obstruction, PULL EMERGENCY HANDLE to release door from Opener. - When Emergency Release is in the released position, the door can be operated manually. - To reconnect, flip the lever on the Trolley towards Opener, back to Connect position, it will reconnect automatically upon pressing Push Button or Remote Control. - DO NOT use Emergency handle to pull the door open or closed. Safety Notice Mount the emergency release within reach, but at least 6 feet above the floor and avoiding contact with vehicles to avoid accidental release. Lever Emergency Release Handle 6 feet (1.83m) above floor 12 Fig. 2 To attach the Emergency Release Handle: 1. Thread one end of the rope through the hole of the Emergency Release Handle and secure with an overhand knot. 2. Thread the other end of the rope through the hole in the Trolley lever. 3. Measure the rope length so that the handle is 6 feet (183cm) above the floor and is clear from the top of your vehicle. Secure with a overhand knot. Wiring Instructions WARNING To prevent SERIOUS INJURY or DEATH from electrocution: - Power MUST NOT be connected until instructed. - NO exposed part of the wire should be visible outside of the terminal for proper connection. Wire from accessories In the following section, the Photo Eye Safety System and Door Control Console will be connected to the Opener. Please read and understand the wiring instructions before connecting wires. 1. Remove the pre-cut skin on the open end of wire from accessories. Wires MUST NOT be frayed and connected properly as shown in Fig.1. 2. To connect a wire to an assigned terminal, use a small “flat head” screwdriver to push in the orange tab on the Wire Terminal as shown in Fig.2. 3. Insert approximately 1/2” (13mm) of the wire into the minal while pushing in the tab as shown in Fig.2. 4. Each accessory requires a pair of terminals, Each pair of terminals MUST be connected with one white wire and one striped wire (non-polarized) from the SAME accessory as shown in Fig.2. 5. Check for proper connection by gently pulling on the wire. The wire should not come out of the terminal. NO exposed part of the wire should be visible outside of the terminal. 6. Use the insulated staples provided to secure the wires to the wall and/or ceiling. Be careful not to damage the wires while securing the staples. Remove and discard pre-cut skin Fig. 1 ter- PHOTO EYE PUSH BUTTON PHOTO EYE PUSH BUTTON Wire Terminals 1/2” Wire shown in actual size Door Control Console Screwdriver or similar tool Min. 5 feet (1.5m) above floor Photo Eye Safety System Fig. 2 13 Connecting Photo Eye Safety System WARNING To prevent SERIOUS INJURY or DEATH from electrocution: - Power MUST NOT be connected BEFORE Photo Eye Safety system is connected and aligned. - The Opener will not operate until the Photo Eye Safety System is properly connected and aligned. - Install the Photo Eyes NO higher than 6” (15cm) above the floor. No part of garage door or other objects should obstruct the Photo Eye Safety System during door-closing. About the Photo Eye Safety System The Photo Eye Safety System provides protection against entrapment while the door is closing. When properly connected and aligned, the emitter Photo Eye emits an invisible infrared light beam while the Sensor Photo Eye monitors that beam. Inside Garage If the beam is obstructed during door-closing, the entrapment protection will be triggered and the door will stop and reverse to the open position. The courtesy light will flash for 30 seconds indicating an obstruction. 6” max. Installing The Photo Eye Safety System Wall-mounting Door Track Inside Garage Door Track Fig. 1 (Wall Mount) Inside Garage 1. Place the Photo Eyes facing each other on each side of the garage door. Position the sensors so they are no higher than 6” (15cm) above the floor, as shown in Fig.1. 2. Drill 3/16” holes using the mounting holes on the Bracket as a template. Secure with 1/4” x 1” Lag Screws (provided). 3. If necessary use the Optional Wall-mount Position (Fig.1) to better fit your door-track and improve obstacle avoidance. To adjust the position, loosen the wing nut, disassemble the Bracket and move the Photo Eye to the lower position on the holder. 4. If necessary, align the Photo Eyes by loosening the wing nut . (This step may be further required in Aligning the Photo Eye Safety System on page 15.) Alignment Loosen 6” max. above floor 1/4 x 1” Lag Screw Alignment Fig. 2 (Floor Mount) Alternative Floor-mounting 1. Place the Photo Eyes facing each other on each side of the garage door, as shown in Fig.2. 2. If attaching to concrete, secure the photo eyes using concrete anchors and bolts (not provided). 3. If necessary, align the Photo Eyes by loosening the wing nut. (This step may be further required in Aligning the Photo Eye Safety System on page 15.) To Connect Photo Eye Safety System From one of the Photo Eye From the other one Fig. 3 14 1. Connect a pair of wires from either one of the Photo Eyes to a pair of “PHOTO EYE” terminals on the rear of the Opener as shown in Fig. 3. Refer to Wiring Instructions on page 12 for proper connections. 2. Repeat above step to connect the other Photo Eye. 3. Refer to Wiring Instructions on page 12 to ensure wires are connected properly. Connecting Door Control Console ! WARNING To prevent SERIOUS INJURY or DEATH from electrocution: - Power MUST NOT be connected until instructed. To prevent SERIOUS INJURY or DEATH from using the Door Control Console or Push Button and a closing door: - Install the Door Control Console or Push Button within sight of the door at a minimum height of 5 feet (1.5m) above the floor. Make sure it is out of the reach of children and moving parts of door and hardware. - NEVER permit children to access the Door Control Console , Push Button or Remote Controls. - Operate the door ONLY when it is adjusted properly with no obstructions present and is in clear sight. - ALWAYS keep a moving door in sight until it’s completely closed. - NEVER cross the path of a moving door. Door Control Console Min. 5 feet (1.5m) above floor In this carton, a Door Control Console has replaced the standard push button as the wired, illuminated door control to be placed inside the garage. Screw #6 x1-3/8” Drywall Anchor To install the Door Control Console: 1. Lift the large actuator cover on door the control console and the upper screw post is exposed 2. Position the door control console at minimum height of 5 feet (1.5m) above the floor to keep out of the reach of children, within sight of door and free from any moving parts on the door. 3. Mark the position of both upper screw post and lower screw hole on the door control console. From Door Control Console 4. Fasten the bottom screw to a solid surface with 1” screws. If attaching to drywall or other hollow surface, drill 3/16” holes and use the provided Drywall Anchors. 5. Align the bottom hole with the bottom screw. Slide the door control down into place. 6. Repeat #4 to secure the door control console with the upper screw 7. Flip down the actuator cover back into place To Connect the Door Control Console to the Opener Connect the pair of wires from the Door Control Console to the pair of “PUSH BUTTON” terminals on the rear of the Opener. Refer to Wiring Instructions on page 12 to ensure wires are properly connected. 15 Connecting Power WARNING To prevent SERIOUS INJURY or DEATH from electrocution or fire: - Power MUST be DISCONNECTED BEFORE proceeding with permanent wiring procedures. - Garage Door Opener installation and wiring MUST be in compliance with all local electrical and building codes. Make sure the Opener is ALWAYS grounded. - NEVER use an extension cord, 2-wire adapter or modify the power plug in any way to make it fit the outlet. DO NOT OPERATE OPENER AT THIS TIME. Ordinary Power Connection To Connect Power Plug the Opener into a grounded outlet ONLY. If there is no grounded outlet present, call a qualified electrician to replace the outlet. Use of a surge protector is highly recommended page 4. Permanent Wiring (If Required by Local Code) 1. 2. For Permanent Wiring ONLY 3. 4. 5. Conduit with wire Line (Black ) Ground (Green/Yellow) Neutral (White) White (from Light) Ground Screw (Green) White (from Logic Board) 6. Black (from Logic Board) Yellow (from Motor) 7. Wire nut (Not provided) 8. 9. Remove the enclosure by removing the 6 screws located on the sides and rear of the Opener. Cut the two cable pressure connectors connecting line (black) and neutral (white) wire from the power cord. Remove the grounding screw connecting the green wire. Remove the power cord. Group neutral (white) wires from power source with 2 white wires from light cable, and logic board, and yellow wire from motor, inside the Opener. Connect them with a wire nut. Group line (black) wires from power source with another black wires from logic board inside the Opener. Connect them with a wire nut. Secure the ground (green or bare) wire from the power source with a grounding screw. Reinstall the enclosure. Turn on power supply. If the wiring is properly connected, a “click” should be heard and the light will illuminate (if a bulb is installed). If there is no response from the Opener, check power source and wiring. Aligning the Photo Eye Safety System WARNING To prevent SERIOUS INJURY or DEATH from a closing garage door: - The Photo Eye Safety System MUST be installed BEFORE connecting power. - The Photo Eye Safety System MUST be properly connected and aligned BEFORE operating the Opener. To Align the Photo Eye Safety System: 1. When the Photo Eye System is properly connected and the power is connected, one of the Photo Eyes will emit a steady green light. This Photo Eye is the Emitter that generates the Invisible Light Beam. 2. When properly aligned, the Sensor should emit a steady red light when it senses the invisible light beam from the Emitter. 3. If the indication is unsteady, flashes or is dim, check for any obstructions and adjust the position until the Sensor gives a STEADY RED LIGHT. Invisible Light Beam 16 Note: The path of the invisible light beam MUST NOT be obstructed. No part of the garage door or any hardware should interfere with the beam or the Opener will not close the door. Travel Limit Adjustment— I. UP Limit ! WARNING To prevent SERIOUS INJURY or DEATH from improper Force Adjustment: - DO NOT adjust force to compensate binding or sticking of the garage door. Call a qualified garage door service person to make necessary adjustments in case of binding. - DO NOT increase force beyond minimum force required for closing the door. Too much force will cause improper operation of safety reversal mechanism. - After ANY adjustments, Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1.5” high object (2x4 laid flat). NOTICE: This opener will not work until you set the travel limits and the travel force adjustment. The opener will beep 5 times if it is operated without programming. About Travel Limit Adjustment I. Setting UP Limit FORCE UP Make sure the trolley is engaged before proceeding adjustments. DOWN LIMIT DOWN Limit Adjustments regulate the fully-open (UP limit) position and fully-closed (DOWN limit) position, at which the door will stop when opening and closing. UP x1 I. Setting UP Limit 1. UP DOWN FORCE UP *NOTE: Once you have pressed and released the “Limit” button, the “UP” light will stay for 10 seconds for you to press the “UP” button and begin programming. If the “UP” light goes out before you are finished you need to start over. DOWN LIMIT 2. Press & hold the “UP” button, the door travels up. You may use both “UP” or “DOWN” buttons to inch-adjust the door to the desired UP limit position. 3. Make sure there is enough clearance for your vehicle(s), and there is a minimum 2” (5cm) gap between Trolley and Stop Bolt. 4. Once the door is at the desired UP limit position, press “LIMIT” button once, “OK” indicator (orange) flashes and goes off. The UP limit is set. Minimum 2” (5cm) clearance Trolley Press “LIMIT” button once to enter Travel Limit Adjustment. “UP” indicator (green) is on*. Stop Bolt OK Flashes and off Desired UP limit UP DOWN FORCE UP LIMIT DOWN 17 Travel Limit Adjustment— II. DOWN Limit ! WARNING To prevent SERIOUS INJURY or DEATH from improper Force Adjustment: - DO NOT adjust force to compensate binding or sticking of the garage door. Call a qualified garage door service person to make necessary adjustments in case of binding. - DO NOT increase force beyond minimum force required for closing the door. Too much force will cause improper operation of safety reversal mechanism. - After ANY adjustments, Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1.5” high object (2x4 laid flat). NOTICE: The opener will not work until you set the travel limits and the travel force adjustment. CAUTION: WHILE SETTING THE DOWN LIMIT, CAREFULLY WATCH DOOR TRAVEL DISTANCE. RELEASE BUTTON WHEN THE DOOR MAKES CONTACT WITH THE GROUND! II. Setting DOWN Limit UP DOWN FORCE UP II. Setting DOWN Limit DOWN LIMIT 1. x2 Following UP limit setting, press “LIMIT” button twice to enter DOWN-limit setting. “DOWN” indicator (red) is on*. *NOTE: Once you have pressed and released the “LIMIT” button, it will stay for 10 seconds for you to press the “DOWN” button and begin programming. If the “DOWN” light goes out before you are finished you need to start over. UP DOWN FORCE LIMIT UP 2. Press & hold the “DOWN” button, the door travels down. You may use both “UP” or “DOWN” buttons to inch-adjust the door to the desired DOWN limit position. 3. Once the door is at the desired DOWN limit position, press “LIMIT” button once, “OK” indicator (orange) flashes and goes off. DOWN limit is set. DOWN OK UP DOWN Desired DOWN limit 18 Flashes and off FORCE UP DOWN LIMIT x1 Both “UP” and “DOWN” (green and red) indicators are now on, indicating that both UP and DOWN limits are set, and the opener is ready for Auto Force Adjustment, see Page19. Auto Force Adjustment ! WARNING To prevent SERIOUS INJURY or DEATH from improper Force Adjustment: - DO NOT adjust force to compensate binding or sticking of the garage door. Call a qualified garage door service person to make necessary adjustments in case of binding. - DO NOT increase force beyond minimum force required for closing the door. Too much force will cause improper operation of safety reversal mechanism. - After ANY adjustments, Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1.5” high object (2x4 laid flat). Following limit-setting, the unit is now ready to automatically adjust the forces for opening and closing the door. Proceed with the following steps to complete adjustment. Auto Force Adjustment FORCE UP UP x1 With both “UP” and “DOWN” indicators are on after Travel Limit Adjustment, press the “FORCE” button once to enter Auto Force Adjustment. 2. The door will travel up automatically (I) and stop at UP limit for 2 seconds (II). Door will then travel down automatically (III) and stop at down limit (IV). 3. The “OK” indicator (orange) will flash with beeps, the Auto Force Adjustment is completed. DOWN LIMIT DOWN 1. II 2s Travels up Stops at UP limit for 2 seconds III IV Travels down Stops at DOWN limit OK Flashes x2 19 Final Adjustments and Testing WARNING To prevent SERIOUS INJURY or DEATH from a closing garage door: - The Safety Reversal Test MUST be conducted ONCE A MONTH. - NO ONE should cross the path of moving door during operation and/or testing. - If either Force or Travel limit adjustment is made, the other adjustment may also needed. - After ANY adjustments to the door system, the Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1-1/2” thick (2x4 laid flat) object. - The Photo Eye Safety System MUST be properly aligned, and tested regularly. Testing the Safety Reverse System The Safety Reverse System prevents the door from closing when an obstruction is present. Travels up 1-1/2” (3.8cm) thick solid object (or 2x4 laid flat) 1. Open the door by using the Push Button. 2. Place a 1-1/2” (3.8cm) thick solid object (or 2x4 laid flat) on floor under the center of garage door. 3. Keeping the door in sight, use the Push Button to close the door. 4. The door MUST REVERSE and beep within 1.5 seconds upon striking the object , and stop at the fully open position. 5. The Safety Reverse System works properly and the opener is ready to use. If the door fails to reverse upon contact with obstruction, adjust the Opener as follows: The close travel maybe inadequate, slightly increase the DOWN limit. (See Travel Limit Adjustment on page 17-19) Door reverses and beeps upon strike Travels down Conduct the test again. If the door reverses on contact, remove the object and run at least 3 COMPLETE travel cycles to ensure proper adjustment. If the Opener still fails the Safety Reverse Test, call a qualified technician for door adjustment. Testing the Photo Eye Safety System Emitter Flashes 20 Open the door by using the Push Button or Remote Control. 2. Make sure both Photo Eyes steadily emit the green and red indicator lights. (If not, check alignment) 3. Place the opener carton in the path of the door. 4. The green indicator on emitter eye will flash and the red indicator light on the sensor eye should be dimmed. 5. Keep the door in sight and use the Push Button or Remote Control to try to close the door. 6. The door should NOT move more than 1” (2.5cm) and the courtesy light should flash for 30 seconds. Sensor x20 GREEN LIGHT 1. Beeps and reverses upon obstruction RED LIGHT OFF Programming Remote Controls * (OPTIONAL) WARNING To Prevent SERIOUS INJURY or DEATH: - Keep remote control and battery out of reach of children. - NEVER permit children to access the Door Control Console, Push Button nor Remote Controls. - Operate the door ONLY when it is properly adjusted, and there are no obstructions present. - ALWAYS keep a moving door in sight until completely closed. NEVER cross the path of a moving door. To reduce risk of fire, explosion or electric shock: - DO NOT short circuit, recharge, dissemble or heat the battery. - Replace with 23AE 12 Volt batteries ONLY. Dispose of batteries properly. Signal and Battery Indicator Visor Clip Holster Fig.1 To Program Remote Control (s): 1. Press/release the “LEARN” button once on the rear control panel, “OK” LED will glow and beep. The unit is now ready to accept a remote control in the next 30 seconds as shown in Fig.2. 2. Press/release any desired button on the Remote Control. 3. The “OK” LED will flash and beep twice indicating Remote Control is stored successfully. Up to 20 Remote Controls (including wireless keypad codes) can be added to the unit by repeating the above procedures. If more than 20 Remote Controls are stored, the first stored Remote Control will be replaced. (i.e. the 21st Remote Control replaces the 1st stored Remote Control .) LEARN OK Removing ALL Remote Controls: 30 seconds To remove ALL Remote Controls from memory, press and hold the “LEARN” button for 5 seconds. The “OK” LED will flash and beep 2 times indicating. ALL Remote Controls have been removed from memory. OK x2 x2 Replacing Remote Control Battery: When the battery of the Remote Control is low, the indicator light will become dim and/or the range of the Remote Control will decrease. To replace the battery, remove the battery cover from the Remote Control as shown in Fig 4. Replace with a 23AE 12 volt alkaline battery with polarity shown in Fig.3. Fig.2 23AE 12 Volt Alkaline Battery This device complies FCC Rules for HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Fig.3 21 Operating the Opener WARNING To Prevent SERIOUS INJURY or DEATH: - READ AND FOLLOW ALL INSTRUCTIONS AND WARNINGS IN THE OWNER’S MANUAL AND LABELS - Keep Remote Control and battery out of reach of children. - NEVER permit children to access the Door Control Console or Remote Controls. - Operate the door ONLY when it is properly adjusted, and there are no obstructions and is in clear sight. - ALWAYS keep a moving door in sight until completely closed. NEVER cross the path of a moving door. - If Travel limit adjustment is made, Force Adjustment may also needed. - After ANY adjustments, the Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1-1/2” thick object (2x4 laid flat). - ALWAYS ensure that your door is balanced and in good working condition. Attach the protective cover to the opener after installation and adjustment is completed. Emergency Release Handle Door Control Console Photo Eye Safety System Invisible Light Beam Actual Operating Scenario Activating the Opener Controls Door Control Console (Indoor) Operation Momentary press the “DOOR” button on the Door Control Console, the door starts to move, and controls as follows: - Open or close the door. - Reverse the door while it is closing - Stops the door while it is opening. Constant press to close the door when the Photo Eye Safety System is not installed, misaligned or obstructed INTENTIONALLY. Press and hold the button until door is fully closed. Remote Control Wireless Keyless Entry Keypad* *Optional 22 Remote distance up to 100ft. in open field. For safety concerns, the Remote Control WILL NOT work if the Photo Eye Safety System is not properly installed and aligned. Program the Wireless Keyless Entry Keypad accordingly and access the door using the PIN code. Operating the Opener Door Status vs. Activation Activation using Door Control Console / Remote Control Door status Door at fully open / close position Door will move to fully close / open position Door is closing Door will reverse Door is opening Door will stop Door is stopped as intended in partially open position Close Door is obstructed while closing Door will reverse while flashing courtesy light Door is obstructed while opening Door will stop Door is fully opened and Photo Eye System is obstructed Door will not close Courtesy Light / Buzzer Responses Operation / Condition Courtesy Light / Buzzer Responses Opener is initially plugged-in (no travel limits stored) Flash x 5 Reconnecting power (with travel limits stored) Flash x 3 “LEARN” button is pressed Beep x 1 Upon activation Light On for 4.5 minutes Upon activation by remote controls Beep x 1, Light On for 4.5 minutes Remote Control / Keyless Entry PIN code accepted Beep x 2 Opener is operated without programming Beep x 5 Door travels with abnormal speed Beep x 12 (1 beep / second) Photo Eye System is obstructed during door-closing Beep x 20 The door is obstructed during travel Beep x 25 Manual Operation WARNING To Prevent SERIOUS INJURY or DEATH: - Use Emergency Release to disconnect Trolley ONLY when the door is CLOSED to prevent unexpected rapid falling in case of a unbalanced / poor-conditioned door. - Use Emergency Release ONLY when doorway is clear of persons and obstructions. - DO NOT use Emergency Release to pull the door open or closed. Lever CONNECT In case of a power failure or door obstruction, EMERGENCY Handle to release door from Opener. To Disconnect Trolley for Manual Operation PULL With the door closed, pull down the emergency release handle to the DISCONNECT position. The door can be raised / lowered manually. To Re-connect Trolley DISCONNECT Flip to reconnect Pull to Disconnect Pull the Handle toward the Opener so that the lever will flip up to the CONNECT position. The Trolley will reconnect itself when the Opener is activated or when the door is manually opened/closed. 23 Maintenance Schedule Once a month Maintenance Door balance test, refer to page 4. Safety reverse test, refer to page 20. Twice a year Check chain/belt tension ( refer to page 6 for adjustment if necessary). Once a year - Limit and Force adjustment may be necessary due to weather conditions. Refer to pages 17-19 for adjustment. Conduct Safety Reverse Test after ANY adjustments. - Lubricate door rollers, bearings and hinges. The Opener is permanently lubricated, DO NOT lubricate or grease the Opener, rail or door tracks. Troubleshooting Problem Possible Cause / Solution Opener does not close and beeps The Photo Eye may be obstructed, not properly aligned or installed, check connection and alignment referring to pages 13 & 16. Opener does not respond to Remote Control - Refer page 21 to reprogram Remote Control. - Check Remote Control battery. Opener stops before reaching full open / close position Travel Limit is not properly adjusted, check adjustment referring to pages 17-19. Conduct Safety Reverse Test after ANY adjustment. The door reverses unintentionally - Make sure the Photo Eye Safety System is aligned and clear of obstructions. - If door is replaced or door condition has significant changes, - Refer to page 4 to check the door balance - Refer to page 17-19 to re-adjust Travel Limits and Travel Force. The door reverses upon touching the floor and Refer to page 17-19 to reset Travel Limits and Travel Force. the courtesy light flashes The Opener does not close the door and the The Photo Eye Safety System is misaligned or obstructed, refer to green LED on the Photo Eyes flashes page16 for proper alignment. The Opener is working properly but the courtesy Replace light bulb (A19 incandescent Max.100W). light does not turn on The courtesy light does not turn off Defective Logic Board. Note: If installing operators on two doors in the same garage, to ensure proper operation, Photo Eyes should be aligned as below: 24 Red LED Green LED Green LED Green LED Red LED Red LED Green LED Red Green LED Red LED Green LED Red LED Repair Parts Installation Parts Item Part No. Name / Description GUAT-027 Header Bracket GUAT-022 Door Bracket GUAT-023 Hardware Bag (Installation hardware shown on P.3) GUAT-024 Curved Door Arm GUAT-025 Straight Door Arm GUAT-026 Emergency Release Handle & Rope Accessories Item Part No. Name / Description GUAT-201 Photo Eye Safety System (Emitter + Sensor with Brackets) R2BCC Remote Control GUAT-203 12V AE23 Alkaline Battery 1-FDCC GUDT-211 Door Control Console Owner’s manual 25 Opener Assembly Parts 10 Item Part No. Name / Description GUDT-301 Chassis GUDT-315 Transformer GUDT-312 Logic Board GUDT-313 DC Motor (with encoder shaft) GUDT-314 Encoder Module GUDT-316 Opener Cover GUDT-309 Lamp Plate GUDT-317 Black Panel GUDT-310 Lamp Dome 10 GUDT-311 Lamp Dome Clip * Should be replaced by qualified technician only 26 WARRANTY GARAGE DOOR OPERATORS Manufacturer hereby warrants: 1. Garage Door Operators to be free from defects in material and workmanship for a period of five (5) years for motors and one (1) year for Electronics and Mechanics from date of purchase, if installed by an authorized reseller, otherwise if installed by the purchaser one (1) year will apply. 2. Garage Door Operators (Commercial and Industrial Application) to be free from defects in material and workmanship for a period of three (3) months from date of purchase. Where the garage door operator has been returned to the manufacturer for Warranty repairs, all costs incurred in the 3. return will be paid for by the purchaser. If in the opinion of the manufacturer the product is faulty, all defective parts will be replaced at no charge to the purchaser. Proof of purchase must be given to the manufacturer at time of Warranty claim. 4. The manufacturer reserves the right to modify any existing or future products without incurring any obligation to incor5. porate such modification to products already manufactured or to which this Warranty may relate. 6. Warranty only applies if this product has been installed to the Manufacturers recommendation This Warranty does not apply to any defect, loss or damage arising or caused directly or indirectly by or as a result of : 7. (i) Any defect (including detects in component parts or accessories) arising from or attributable to the failure to carry out normal preventive maintenance or adjustment itself. (ii) To any additional damage or deterioration arising from attributable to the operation of the Operator after it is known to be defective. 8. Exclusions to Warranty Period: (i) Repair or Warranty Work - three (3) month 9. Not included in Warranty: (i) Batteries. (ii) Fuses. (iii) Light bulbs. Sensitivity adjustment. (iv) (v) Handheld Remote Controls and receiver range. 10. Note : All Warranties will be void subject to: (i) Water damage and condensation. (ii) Power supply black out or surge. (iii) Act of God. (iv) Modification or adjustment by unauthorized persons. (v) Any interference from radio (including citizen band radios or and other electronic device) (vi) Preventative maintenance and regular servicing not undertaken. (vii) Account not paid in full by the purchaser. 11. Subject only to the provisions of the Trade practices Act and any legislation of the State or Territory wherein the operators of the Manufacturer have been sold or installed (which may confer certain rights on consumers of goods and those rights by such legislation may be rendered incapable of exclusion) this Warranty supersedes and excludes all representations, warranties and conditions whether expressed or implied by law and the Manufacturer shall have no liability or otherwise than herein provided for any loss and damage (including consequential loss and damage, loss of use or profits) by reasons of delay, defective or faulty materials or workmanship, negligence or any act, matter or thing done permitted or omitted to be done by the Manufacturer. WARRANTY THIS WARRANTY FORM SHOULD BE COMPLETED AT TIME OF INSTALLATION This Warranty Form should be retained by the purchaser at all times and produced with the purchase docket by the Purchaser as proof of the purchase date. PURCHASER’S NAME: PURCHASER’S ADDRESS: INSTALLED BY: INSTALLER’S ADDRESS: INSTALLER’S SIGNATURE: SERIAL NUMBER OF THE OPERATOR: GUARDIAN SERVICE Your operator has been installed by a professional installation specialist. If service information is required please contact the installing company or your local Guardian dealer. Look for your Guardian dealer online, in the yellow pages or call our service number for a dealer near you. Service number : 1-424-272-6998 Please have the following information when you call: ·Model number of the operator ·Serial number of the operator--located on the bar code label on top of the opener, above the adjustment buttons FCC Warning: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : wulianlian Create Date : 2017:03:09 16:25:32+08:00 Modify Date : 2017:10:26 16:13:25-07:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:10:26 16:13:25-07:00 Producer : Acrobat Distiller 10.1.0 (Windows) Format : application/pdf Title : L5112-T-GU_615_150710 Creator : wulianlian Document ID : uuid:49330fe9-b1ce-412d-91ef-6b4c1e260230 Instance ID : uuid:6aad68c2-e79f-46aa-92db-79ff5250300e Page Count : 28EXIF Metadata provided by EXIF.tools