Gallagher Group C30020X Prox Reader T10 Mifare User Manual

Gallagher Group Ltd Prox Reader T10 Mifare Users Manual

Users Manual

Download: Gallagher Group C30020X Prox Reader T10 Mifare User Manual
Mirror Download [FCC.gov]Gallagher Group C30020X Prox Reader T10 Mifare User Manual
Document ID1388134
Application ID5PMSt8fdWHR9Un/dC95RCQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.52kB (606545 bits)
Date Submitted2010-12-09 00:00:00
Date Available2010-12-09 00:00:00
Creation Date2010-11-30 09:19:20
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2010-11-30 09:19:23
Document TitleUsers Manual
Document CreatorAdobe InDesign CS3 (5.0)

Installation Note | Gallagher T10 Mifare Reader
Installation Note
Gallagher T10 Mifare Reader
This equipment contains components that can be damaged by
electrostatic discharge. Ensure both you and the equipment are
earthed before beginning any servicing.
The Gallagher T10 Mifare Reader
The Gallagher T10 Mifare reader is a smart card proximity reader. It can
be installed as either an entry reader or exit reader.
The reader can read Mifare DESFire EV1, Mifare Plus and Mifare Classic
cards.
The reader sends information to the Cardax FT Controller and acts upon
information sent from the Cardax FT Controller. The reader itself does not
make any access decisions.
The Gallagher T10 Mifare reader uses the “Cardax IV Reader”
communications protocol to communicate with the Cardax FT Controller.
Part Number: 3E2453 R1 | 1
Installation Note | Gallagher T10 Mifare Reader
Before you begin
Shipment Contents
Check the shipment contains the following items:
•
•
•
•
•
1 x Gallagher T10 Mifare reader facia assembly
1 x Gallagher T10 Mifare reader base
1 x Gallagher T10 Mifare reader installation note
1 x M3 Torx Post Security screw
2 x self tapping pan head pozi fixing screws
Power Supply
The Gallagher T10 Mifare reader receives power from the device to which
it is connected. The reader is designed to operate over a supply voltage
range of 9 - 16Vdc measured at the reader terminals. The operating
current will be approximately 40mA (at 16Vdc) and 70mA (at 9Vdc).
The operating current will increase to approximately 120mA (at 12Vdc)
momentarily during a card read, beeper and LED activity.
The power source should be linear or a good quality switched-mode power
supply. The performance of the reader may be affected by a low quality,
noisy power supply.
Cabling
The Gallagher T10 Mifare reader requires a minimum cable size of 4
core 24 AWG (0.2mm2) stranded security cable. This cable allows the
transmission of data (2 wires) and power (2 wires). When using a single
cable to carry both power supply and data, both the power supply voltage
drop and data requirements must be considered. For good engineering
design, it is recommended that the voltage at the reader should be
approximately 12Vdc.
The critical specifications for the cable are:
Data:
The capacitance between any two wires or between
a wire and any shielding should be less than 24nF
Power supply: The voltage at the reader must be at least 9Vdc
Examples of approved cables for connecting a single Gallagher T10 Mifare
reader to a Controller and power supply, showing maximum cable lengths
for each type of cable and the associated circuits are:
2 | Part Number: 3E2453 R1
Installation Note | Gallagher T10 Mifare Reader
Cable type
Combined power and data
in a single cable
CAT5e
SEC472 (4 x 0.2mm2)
SEC4142 (4 x 0.4mm2)
BELDEN 8723 (22 AWG)
BELDEN 9842 (24 AWG)
100m
100m
100m
152m
152m
(320ft)
(320ft)
(320ft)
(500ft)
(500ft)
Distance between Proximity Readers
The distance separating any two proximity readers must not be less than
200mm (8 inches) in all directions.
200mm
200m
Wall thickness
less than 200mm
When mounting a proximity reader on an internal wall, check that any
reader fixed to the other side of the wall is not less than 200mm (8 inches)
away.
Installation
The Gallagher T10 Mifare reader is designed to be mounted on any solid
flat surface. However installation on metal surfaces, particularly those with
a large surface area will reduce read range. The extent to which the range
is reduced will depend upon the type of metal used.
The recommended mounting height for the reader is 1.1m (3.6ft) from the
floor level to the centre of the reader device. However this may vary in
some countries and you should check local regulations for variations to this
height.
Part Number: 3E2453 R1 | 3
Installation Note | Gallagher T10 Mifare Reader
1.
Using the drill template at the back of this installation note as a
guide, drill all three holes. Drill the 13mm (1/2 inch) diameter centre
hole (this is the centre hole for which the building cable will exit the
mounting surface) and the two fixing holes.
2.
Run the building cabling out through the centre hole and through the
reader base.
3.
Secure the base to the mounting surface using the two fixing screws
provided. It is important the base of the reader is flush with and tight
against the mounting surface.
Note: Ensure the centre hole allows the cable to run freely out through
the mounting surface, so that the reader facia can clip into the base.
Base
6 Gauge screw
Building cable
6 Gauge screw
4.
Connect the reader tail extending from the facia assembly to the
building cable. Connect the wires shown below.
Cardax IV Reader
Note: Do not cut the ‘Reserved’ wires, they may be required later.
5.
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
Fit the facia assembly into the base by clipping the small lip, into the
top of the base and holding the top, press the bottom of the facia
assembly down into the base.
4 | Part Number: 3E2453 R1
Installation Note | Gallagher T10 Mifare Reader
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security
screwdriver) through the hole at the bottom of the base to secure the
facia assembly.
Note: The recommended torque for the security screw is 0.7Nm
(0.5 lb/ft). It is important not to exceed the maximum torque of
1.5Nm (1.1 lb/ft).
Facia
Reader
tail
Building
cable
Connection
7.
Fit screw to secure facia to base
Removal of the facia assembly is a simple reversal of these steps.
Connections
A Gallagher T10 Mifare reader can connect to one of the following devices
using the “Cardax IV Reader” communications protocol:
•
•
•
•
•
Cardax FT Reader Module (for the Controller 6000)
Cardax FT GBUS Universal Reader Interface (Cardax FT GBUS URI)
Cardax FT Controller 3000-4R or 3000-8R
Cardax FT Universal Reader Interface (Cardax FT URI)
Cardax FT Reader I/O Interface
Part Number: 3E2453 R1 | 5
Installation Note | Gallagher T10 Mifare Reader
Connecting to the Cardax FT Reader Module (for the Controller 6000)
Red
Black
Orange
Green
Brown
White
Blue
R2 Out
R2 In
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
R1 Out
R1 In
Red
Black
Orange
Green
Brown
White
Blue
Cardax IV Reader 2
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Cardax IV Reader 1
Connect the wires to the sockets as shown:
Cardax FT Reader Module
Connecting to the Cardax FT GBUS Universal Reader Interface
Connect the wires to the sockets as shown in either of the following diagrams:
6 | Part Number: 3E2453 R1
Cardax IV Reader
Cardax IV Reader
GND
VIN
GND
VOUT
GND
TAMPER
COM B
COM A
OUT 2
Red
Black
Orange
Green
Brown
White
Blue
OUT 1
Top Row
Pin 1
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
DATA 1
Reader
DATA 0
RLY 2 NC
RLY 2 NO
Pin 15
RLY 2 COM
GND
VIN
GND
VOUT
GND
TAMPER
COM B
COM A
OUT 2
Top Row
Pin 1
Red
Black
Orange
Green
Brown
White
Blue
OUT 1
Cardax FT GBUS URI
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
DATA 1
Reader
DATA 0
RLY 2 NO
RLY 2 COM
Pin 15
RLY 2 NC
Cardax FT GBUS URI
Installation Note | Gallagher T10 Mifare Reader
Connecting to the Cardax FT Controller 3000-4R or 3000-8R
The Cardax FT Controller 3000-4R can interface up to four Gallagher T10
Mifare readers into the Cardax FT Command Centre system. The Cardax
FT Controller 3000-8R can interface up to eight Gallagher T10 Mifare
readers into the Cardax FT Command Centre system.
The ports to which the Gallagher T10 Mifare reader can connect are set up
as groups, as follows:
• Two groups (numbered 1 and 2) on the Controller 3000-4R, and
• Four groups (numbered 1 to 4) on the Controller 3000-8R
Each group provides connection for two Gallagher T10 Mifare readers.
Refer to the following diagram for the location of the ports on the Cardax
FT Controller 3000-8R.
Note: Even though there are only two groups of ports on the Cardax FT
Controller 3000-4R, they are located in the same position.
Part Number: 3E2453 R1 | 7
Installation Note | Gallagher T10 Mifare Reader
Make the connections from the Gallagher T10 Mifare reader to either the
Cardax FT Controller 3000-4R or 3000-8R as shown:
Cardax FT Controller 3000-4R or 3000-8R
Group
PB1 and PA1... to... PB2 and PA2 (3000-4R)
PB4 and PA4 (3000-8R)
OUT 2
OUT 1
DATA 1
DATA 0
Red
Black
Orange
Green
Brown
White
Blue
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
2 0V
1 V OUT
PA
PB
Cardax IV Reader
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV readers with Wiegand
Readers. This is because connecting one Wiegand reader requires all four
pins on plug PB. For example, if you connect a Cardax IV reader to Port
1 of Group 1, Port 2 of Group 1 can only connect to another Cardax IV
reader.
8 | Part Number: 3E2453 R1
Installation Note | Gallagher T10 Mifare Reader
Technical Specifications
Technical Specifications
Routine maintenance
Not applicable for this reader
Cleaning
This reader should only be cleaned with a clean, lint
free, damp cloth
Power required
Voltage: 9Vdc - 16Vdc
Current: 40mA (at 16Vdc)
70mA (at 9Vdc)
The current will increase momentarily during a card
read, beeper and LED activity: 120mA (at 12Vdc)
Environmental
Operating temperature: -30°C to +70°C
Note: Direct sunlight may increase the internal reader
temperature above the ambient temperature level
Humidity: 95% non-condensing
Mounting height
Environmental Protection: IP67*
* Pending final test results
1.1m (3.6ft) to centre
Approvals and Standards
This product complies with the environmental regulations for the
Restriction of Hazardous Substances in electrical and electronic
equipment (RoHS). The RoHS directive prohibits the use of
electronic equipment containing certain hazardous substances
in the European Union.
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it
is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the recycling
of waste electrical and electronic equipment. The separate
collection and recycling of your waste equipment at the time
of disposal will help conserve natural resources and ensure
that it is recycled in a manner that protects human health and
the environment. For more information about where you can
drop off your waste equipment for recycling, please contact
your local city recycling office or the dealer from whom you
purchased the product.
ACN 002 132 943
Part Number: 3E2453 R1 | 9
Installation Note | Gallagher T10 Mifare Reader
FCC
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
Note: Changes or modifications not expressly approved by
Gallagher Group Limited could void the user’s authority to
operate this equipment.
10 | Part Number: 3E2453 R1
40mm (1.57 inches)
13mm (1/2 inch)
diameter hole for cable
40mm (1.57 inches)
44mm (1.73 inches)
115mm (4.53 inches)
Drill Template
22.5mm
(0.89 inches)
35mm (1.38 inches)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Instance ID                     : uuid:c7bafb21-b2d9-418c-919d-836569a54d61
Document ID                     : adobe:docid:indd:f96526b2-a0ce-11df-8595-adfd5648a1ab
Rendition Class                 : proof:pdf
Derived From Instance ID        : f96526b1-a0ce-11df-8595-adfd5648a1ab
Derived From Document ID        : adobe:docid:indd:fc6fd836-99e4-11df-a81b-ad8897a2c7d1
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 96.00, 96.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 96.00, 96.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:75FED71E9BA5DF11B3ABE23FDD712A4F, uuid:75FED71E9BA5DF11B3ABE23FDD712A4F, uuid:75FED71E9BA5DF11B3ABE23FDD712A4F, uuid:FE76A0D309B7DF11A13DD5150BA58730, uuid:8212C78146AEDF119726DDC9C185D410, uuid:8212C78146AEDF119726DDC9C185D410, uuid:0D4ACA052BB9DF11AB80AE0F172C0CEB, uuid:FE76A0D309B7DF11A13DD5150BA58730, uuid:E4F7AC0BAEA5DF11B3ABE23FDD712A4F, uuid:B0603969E29DDF118ABADD8285393736, uuid:2413B414F5FBDF11BD6AFC4A3372C3BE, uuid:C90870BAF4FBDF11BD6AFC4A3372C3BE, uuid:A4D73BE77E9BDF11BAF4D606A4A35B78
Manifest Reference Document ID  : uuid:FD76A0D309B7DF11A13DD5150BA58730, uuid:33794F7F5A9BDF11BAF4D606A4A35B78, uuid:33794F7F5A9BDF11BAF4D606A4A35B78, uuid:71DC0D200CB7DF11A13DD5150BA58730, uuid:FD76A0D309B7DF11A13DD5150BA58730, uuid:CA3C56D1F295DF11A539C0E32448F2FF, uuid:157b15ea-6853-4650-a85b-60fb10ddd696, uuid:2313B414F5FBDF11BD6AFC4A3372C3BE, uuid:C50870BAF4FBDF11BD6AFC4A3372C3BE, uuid:A3D73BE77E9BDF11BAF4D606A4A35B78
Create Date                     : 2010:11:30 09:19:20+13:00
Modify Date                     : 2010:11:30 09:19:23+13:00
Metadata Date                   : 2010:11:30 09:19:23+13:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8107 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 11
Creator                         : Adobe InDesign CS3 (5.0)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M5VC30020X

Navigation menu