Gallagher Group C30024X Prox Reader T11 Multi Tech and T12 Multi Tech User Manual 2

Gallagher Group Ltd Prox Reader T11 Multi Tech and T12 Multi Tech Users Manual 2

Contents

Users Manual 2

Download: Gallagher Group C30024X Prox Reader T11 Multi Tech and T12 Multi Tech User Manual 2
Mirror Download [FCC.gov]Gallagher Group C30024X Prox Reader T11 Multi Tech and T12 Multi Tech User Manual 2
Document ID1438869
Application ID9Xh97FuIkDwlOVk+/Lk7Bg==
Document DescriptionUsers Manual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize57.48kB (718469 bits)
Date Submitted2011-03-28 00:00:00
Date Available2011-03-29 00:00:00
Creation Date2011-03-07 14:48:26
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2011-03-07 14:48:30
Document TitleUsers Manual 2
Document CreatorAdobe InDesign CS3 (5.0)

Installation Note | Gallagher T11 Reader
Installation Note
Gallagher T11 Reader
This equipment contains components that can be damaged by electrostatic
discharge. Ensure both you and the equipment are earthed before beginning
any servicing.
The Gallagher T11 Reader
The Gallagher T11 Reader is a smart card proximity reader. It can be installed as
either an entry reader or exit reader. It can be mounted on any standard electrical
flush (gang) box, used in New Zealand, Australia, USA and Canada.
The reader can read Mifare DESFire EV1, Mifare Plus and Mifare Classic cards. The
Multi Tech variant can also read 125Khz cards.
The reader sends information to the Cardax FT Controller and acts upon information
sent from the Cardax FT Controller. The reader itself does not make any access
decisions.
The Gallagher T11 Reader uses the “Cardax IV Reader” communications protocol
to communicate with the Cardax FT Controller.
Part Number: 3E2513 R1 | 1
Installation Note | Gallagher T11 Reader
Before you begin
Shipment Contents
Check the shipment contains the following items:
• 1 x Gallagher T11 Reader facia assembly
• 1 x Gallagher T11 Reader base
• 1 x M3 Torx Post Security screw
• 2 x 6-32 UNC screws
• 4 x self tapping, pan head, pozi fixing screws
Power Supply
The Gallagher T11 Reader is designed to operate over a supply voltage range of
9 - 16Vdc measured at the reader terminals. The operating current draw is dependant
on the supply voltage at the reader. For the Standard variant at 12Vdc the current
draw is 54mA (standby). During card read, beeper and LED activity, the current will
momentarily reach 100mA (peak). For the Multi Tech variant at 12Vdc the current
draw is 88mA (standby) and will momentarily reach 140mA (peak).
The power source should be linear or a good quality switched-mode power supply. The
performance of the reader may be affected by a low quality, noisy power supply.
Cabling
The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG
(0.2mm2) stranded security cable. This cable allows the transmission of data (2 wires)
and power (2 wires). When using a single cable to carry both power supply and
data, both the power supply voltage drop and data requirements must be considered.
Although the reader is specified to operate at 9Vdc, for good engineering design it
is recommended that the voltage at the reader should be approximately 12Vdc.
Examples of approved cables for connecting a single Gallagher T11 Reader to a
Controller and power supply, showing maximum cable lengths for each type of cable
and the associated circuits are:
Manufacturer
reference
Cable format*
Combined
power and data
in a single cable
Data only in a
single cable
CAT5E
4 twisted pair
Each 2 x 0.2mm2 (24 AWG)
100m (330ft)
300m (1000ft)
SEC472
4 x 0.2mm2
Not twisted pairs (24 AWG)
100m (330ft)
250m (800ft)
SEC4142
4 x 0.4mm2
Not twisted pairs (21 AWG)
150m (500ft)
150m (500ft)
BELDEN 8723
2 twisted pair
Each 2 x 0.4mm2 (22 AWG)
100m (330ft)
150m (500ft)
BELDEN 9842
2 twisted pair
Each 2 x 0.2mm2 (24 AWG)
100m (330ft)
200m (650ft)
2 | Part Number: 3E2513 R1
Installation Note | Gallagher T11 Reader
* The matching of wire sizes to equivalent wire gauges are only approximate.
Note: Grounding shielded cable may reduce the obtainable cable length by 25%
to 30%.
Distance between Proximity Readers
The distance separating any two proximity readers must not be less than 200mm
(8 inches) in all directions.
200mm
When mounting a proximity reader on an internal wall, check that any reader fixed
to the other side of the wall is not less than 200mm (8 inches) away.
200m
Installation
The Gallagher T11 Reader is designed to be mounted on vertically orientated electrical
flush (gang) boxes, or any solid flat surface. However installation on metal surfaces,
particularly those with a large surface area will reduce read range. The extent to
which the range is reduced will depend upon the type of metal used.
The recommended mounting height for the reader is 1.1m (3.6 ft) from the floor
level to the centre of the reader device. However this may vary in some countries
and you should check local regulations for variations to this height.
1.
Ensure the building cable has been run out through the flush box.
If you are not mounting to a flush box, use the drill template at the back of this
installation note as a guide, to drill all five holes. Drill the 13mm (1/2 inch)
diameter centre hole (this is the centre hole for which the building cable will
exit the mounting surface) and the four fixing holes.
2.
Run the building cabling through the reader base.
Part Number: 3E2513 R1 | 3
Installation Note | Gallagher T11 Reader
3.
Secure the base to the flush box using the two 6-32 UNC screws provided. It
is important the base of the reader is flush with and tight against the mounting
surface.
If you are not mounting to a flush box, secure the base to the mounting surface
using the four fixing screws provided.
Base
6-32 UNC screw
Building cable
6-32 UNC screw
4.
Connect the reader tail extending from the facia assembly to the building cable.
Connect the wires shown below.
Cardax IV Reader
Note: Do not cut the ‘Reserved’ wires, they may be required later.
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
5.
Fit the facia assembly into the base by clipping the small lip, into the top of
the base and holding the top, press the bottom of the facia assembly down
into the base.
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver)
through the hole at the bottom of the base to secure the facia assembly.
Note: The recommended torque for the security screw is 0.7Nm (0.5 lb/ft). It
is important not to exceed the maximum torque of 1.5Nm (1.1 lb/ft).
4 | Part Number: 3E2513 R1
Installation Note | Gallagher T11 Reader
Facia
Reader
tail
Connection
7.
Fit screw to secure facia to base
Removal of the facia assembly is a simple reversal of these steps.
Connections
A Gallagher T11 Reader can connect to one of the following devices using the
“Cardax IV Reader” communications protocol:
•
•
•
•
•
Cardax FT Reader Module (for the Controller 6000)
Cardax FT GBUS Universal Reader Interface (Cardax FT GBUS URI)
Cardax FT Controller 3000-4R or 3000-8R
Cardax FT Universal Reader Interface (Cardax FT URI)
Cardax FT Reader I/O Interface
Part Number: 3E2513 R1 | 5
Installation Note | Gallagher T11 Reader
Connecting to the Cardax FT Reader Module (for the Controller 6000)
Red
Black
Orange
Green
Brown
White
Blue
R2 Out
R2 In
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
R1 Out
R1 In
Red
Black
Orange
Green
Brown
White
Blue
Cardax IV Reader 2
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Cardax IV Reader 1
Connect the wires to the sockets as shown:
Cardax FT Reader Module
Connecting to the Cardax FT GBUS Universal Reader Interface
Connect the wires to the sockets as shown in either of the following diagrams:
6 | Part Number: 3E2513 R1
Cardax IV Reader
Cardax IV Reader
GND
VIN
GND
VOUT
GND
TAMPER
COM B
COM A
OUT 2
Red
Black
Orange
Green
Brown
White
Blue
OUT 1
Top Row
Pin 1
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
DATA 1
Reader
DATA 0
RLY 2 NC
RLY 2 NO
Pin 15
RLY 2 COM
GND
VIN
GND
VOUT
GND
TAMPER
COM B
COM A
OUT 2
Top Row
Pin 1
Red
Black
Orange
Green
Brown
White
Blue
OUT 1
Cardax FT GBUS URI
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
DATA 1
Reader
DATA 0
RLY 2 NO
RLY 2 COM
Pin 15
RLY 2 NC
Cardax FT GBUS URI
Installation Note | Gallagher T11 Reader
Connecting to the Cardax FT Controller 3000-4R or 3000-8R
The ports to which the Gallagher T11 Reader can connect are set up as groups, as
follows:
• Two groups (numbered 1 and 2) on the Controller 3000-4R, and
• Four groups (numbered 1 to 4) on the Controller 3000-8R
Each group provides connection for two Gallagher T11 Readers. Refer to the following
diagram for the location of the ports on the Cardax FT Controller 3000-8R.
Part Number: 3E2513 R1 | 7
Installation Note | Gallagher T11 Reader
Make the connections from the Gallagher T11 Reader to either the Cardax FT
Controller 3000-4R or 3000-8R as shown:
Cardax FT Controller 3000-4R or 3000-8R
Group
PB1 and PA1... to... PB2 and PA2 (3000-4R)
PB4 and PA4 (3000-8R)
OUT 2
OUT 1
DATA 1
DATA 0
Red
Black
Orange
Green
Brown
White
Blue
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
2 0V
1 V OUT
PA
PB
Cardax IV Reader
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV readers with Wiegand Readers.
This is because connecting one Wiegand reader requires all four pins on plug PB. For
example, if you connect a Cardax IV reader to Port 1 of Group 1, Port 2 of Group
1 can only connect to another Cardax IV reader.
8 | Part Number: 3E2513 R1
Installation Note | Gallagher T11 Reader
Technical Specifications
Technical Specifications
Routine maintenance: Not applicable for this reader
Cleaning:
This reader should only be cleaned with a clean, lint
free, damp cloth
Power required:
Voltage: 9Vdc - 16Vdc
Current (at 12Vdc): 54mA (standby) Standard variant
100mA (peak) Standard variant
88mA (standby) Multi Tech variant
140mA (peak) Multi Tech variant
Temperature Range: -30°C to +70°C
Note: Direct sunlight may increase the internal reader
temperature above the ambient temperature level.
Humidity: 95% non-condensing
Environmental:
Environmental Protection: IP68
Impact Rating: IK07
Approvals and Standards
This product complies with the environmental regulations for the
Restriction of Hazardous Substances in electrical and electronic
equipment (RoHS). The RoHS directive prohibits the use of
electronic equipment containing certain hazardous substances in
the European Union.
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it is
your responsibility to dispose of your waste equipment by handing
it over to a designated collection point for the recycling of waste
electrical and electronic equipment. The separate collection and
recycling of your waste equipment at the time of disposal will
help conserve natural resources and ensure that it is recycled in a
manner that protects human health and the environment. For more
information about where you can drop off your waste equipment
for recycling, please contact your local city recycling office or the
dealer from whom you purchased the product.
ACN 002 132 943
Part Number: 3E2513 R1 | 9
Installation Note | Gallagher T11 Reader
FCC
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
Note: Changes or modifications not expressly approved by
Gallagher Group Limited could void the user’s authority to operate
this equipment.
10 | Part Number: 3E2513 R1
22.5mm
(0.89 inches)
40mm (1.57 inches)
70mm (2.76 inches)
115mm (4.53 inches)
13mm (1/2 inch)
diameter hole for cable
40mm (1.57 inches)
36mm (1.42 inches)
44mm (1.73 inches)
Drill Template

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Instance ID                     : uuid:784861ac-8279-4663-881b-75bcae22c53e
Document ID                     : adobe:docid:indd:f96526b2-a0ce-11df-8595-adfd5648a1ab
Rendition Class                 : proof:pdf
Derived From Instance ID        : f96526b1-a0ce-11df-8595-adfd5648a1ab
Derived From Document ID        : adobe:docid:indd:fc6fd836-99e4-11df-a81b-ad8897a2c7d1
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 96.00, 96.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 96.00, 96.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:540B1478BBA5DF11B3ABE23FDD712A4F, uuid:540B1478BBA5DF11B3ABE23FDD712A4F, uuid:540B1478BBA5DF11B3ABE23FDD712A4F, uuid:F7C1332F4AB9DF1184F5956EEF70537D, uuid:ED95A74449B9DF1184F5956EEF70537D, uuid:ED95A74449B9DF1184F5956EEF70537D, uuid:F7C1332F4AB9DF1184F5956EEF70537D, uuid:4E0B1478BBA5DF11B3ABE23FDD712A4F, uuid:E4F7AC0BAEA5DF11B3ABE23FDD712A4F, uuid:B0603969E29DDF118ABADD8285393736, uuid:2413B414F5FBDF11BD6AFC4A3372C3BE, uuid:C90870BAF4FBDF11BD6AFC4A3372C3BE, uuid:A4D73BE77E9BDF11BAF4D606A4A35B78
Manifest Reference Document ID  : uuid:F6C1332F4AB9DF1184F5956EEF70537D, uuid:33794F7F5A9BDF11BAF4D606A4A35B78, uuid:33794F7F5A9BDF11BAF4D606A4A35B78, uuid:F6C1332F4AB9DF1184F5956EEF70537D, uuid:88F5D295F2A3DF118FDD956101E5F9DA, uuid:CA3C56D1F295DF11A539C0E32448F2FF, uuid:157b15ea-6853-4650-a85b-60fb10ddd696, uuid:2313B414F5FBDF11BD6AFC4A3372C3BE, uuid:C50870BAF4FBDF11BD6AFC4A3372C3BE, uuid:A3D73BE77E9BDF11BAF4D606A4A35B78
Create Date                     : 2011:03:07 14:48:26+13:00
Modify Date                     : 2011:03:07 14:48:30+13:00
Metadata Date                   : 2011:03:07 14:48:30+13:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8624 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 11
Creator                         : Adobe InDesign CS3 (5.0)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M5VC30024X

Navigation menu