Gallagher Group C30040XA Prox Readers T10 Mifare and T10 Mifare PIV User Manual

Gallagher Group Ltd Prox Readers T10 Mifare and T10 Mifare PIV Users Manual

Users Manual

Page  1   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedGallagher T10 ReaderInstallaon NoteT10 Mifare Reader Black: C300400T10 Mifare Reader White: C300401T10 PIV Reader Black: C305400T10 PIV Reader White: C305401
Page  2   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedDisclaimerThis document gives certain informaon about products and/or services provided by Gallagher Group Limited or its related companies (referred to as "Gallagher Group").The informaon is indicave only and is subject to change without noce meaning it may be out of date at any given me.  Although every commercially reasonable eort has been taken to ensure the quality and accuracy of the informaon, Gallagher Group makes no representaon as to its accuracy or completeness and it should not be relied on as such.  To the extent permied by law, all express or implied, or other representaons or warranes in relaon to the informaon are expressly excluded. Neither Gallagher Group nor any of its directors, employees or other representaves shall be responsible for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the informaon provided.Except where stated otherwise, the informaon is subject to copyright owned by Gallagher Group and you may not sell it without permission.  Gallagher Group is the owner of all trademarks reproduced in this informaon.  All trademarks which are not the property of Gallagher Group, are acknowledged.Copyright © Gallagher Group Ltd 2016.  All rights reserved.
Page  3   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedContents1  Introducon ..................................................................................................................................... 42  Before you begin .............................................................................................................................. 43  Distance between readers ............................................................................................................... 74  Installaon ....................................................................................................................................... 75  LED indicaons ................................................................................................................................. 96  Accessories .................................................................................................................................... 107  Technical specicaons .................................................................................................................. 108  Approvals and standards ................................................................................................................ 119  Mounng dimensions .................................................................................................................... 12
Page  4   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited1 IntroduconThe Gallagher T10 Reader is a smart card proximity reader.  It can be installed as either an entry reader or exit reader.  The reader sends informaon to the Gallagher Controller and acts upon informaon sent from the Gallagher Controller.  The reader itself does not make any access decisions.The reader is available in four variants.  The card technologies for each variant are shown below.Reader Product codes Supported card technologiesT10 Mifare Reader Black  T10 Mifare Reader WhiteC300400 C300401Mifare DESFire EV1, Mifare Plus and Mifare ClassicT10 PIV Reader Black T10 PIV Reader WhiteC305400 C305401PIV, PIV-I, Mifare DESFire EV1, Mifare Plus and Mifare ClassicThe reader can be connected as an HBUS Reader or Cardax IV Reader.  An HBUS Reader uses the HBUS communicaons protocol to communicate with the Gallagher Controller.  A Cardax IV Reader uses the Cardax IV Reader communicaons protocol to communicate with the Gallagher Controller.  IMPORTANT:HBUScompability HBUS communicaons are supported with sites running Gallagher Command Centre vEL7.00 soware (or later).IMPORTANT: PIV readers Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only (referred to as the Controller).  Gallagher PIV readers can only be used with sites running Gallagher Command Centre vEL7.10 soware (or later).  Gallagher PIV readers are connected as HBUS Readers only.2 Beforeyoubegin2.1  Shipment contentsCheck the shipment contains the following items:•  1 x Gallagher T10 Reader facia assembly•  1 x Gallagher T10 Reader bezel•  1 x M3 Torx Post Security screw•  2 x 25 mm No.6 self tapping, pan head, Phillips drive xing screws•  2 x 40 mm No.6 self tapping, pan head, Phillips drive xing screws2.2 PowersupplyThe Gallagher T10 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals.  The operang current draw is dependant on the supply voltage at the reader.  The power source should be linear or a good quality switched-mode power supply.  The performance of the reader may be aected by a low quality, noisy power supply.
Page  5   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited2.3 CablingThe Gallagher T10 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded security cable.  This cable allows the transmission of data (2 wires) and power (2 wires).  When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered.  Although the reader is specied to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc. HBUScablingtopologyThe HBUS communicaons protocol is based on the RS485 standard and allows the reader to communicate over a distance of up to 500 m (1640 ).The cabling between HBUS devices should be done in a "daisy chain" topology, (i.e. A "T" or "Star" topology should not be used between devices).  Should "Star" or "Home-Run" wiring be required, the HBUS 4H/8H Modules and the HBUS Door Module allow mulple HBUS devices to be individually wired to the one physical locaon.The end devices on the HBUS cable should be terminated using 120 ohms resistance.  To terminate the Gallagher Controller 6000, connect the supplied on-board terminaon jumpers to the Controller.  To terminate a reader, connect the orange (terminaon) wire to the green (HBUS A) wire.  Terminaon is already included at the HBUS Module, (i.e. each HBUS port is permanently terminated at the module).Connect the on-board terminaon jumperController 6000RS485 1HBUS Device"T" or "Star" circuits are not permied between HBUS devicesHBUS DeviceTerminateHBUS DeviceHBUS DeviceHBUS DeviceHBUS DeviceHBUS DeviceHBUS DeviceTerminateRemove the on-board terminaon jumperRS485 1"T" or "Star" circuits are not permied between HBUS devicesHBUS DeviceTerminateHBUS Device Controller 6000
Page 6   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedHBUS Device"T" or "Star" circuits are not permied between HBUS devicesController 6000H1 H4H8H5HBUS DeviceTerminateHBUS DeviceTerminateHBUS ModuleHBUS DeviceHBUS DeviceTerminateHBUS DeviceTerminateHBUS Device CabledistanceCabletype Cableformat* HBUS  single reader connected using dataonlyinasinglecableCardax IV single reader connected using dataonlyinasinglecableHBUS/Cardax IV single reader connected  using  power and data inasinglecableCAT 5e or beer**4 twisted pair Each 2 x 0.2 mm2 (24 AWG)500 m (1640 ) 200 m (650 ) 100 m (330 )BELDEN 9842** (shielded)2 twisted pair Each 2 x 0.2 mm2 (24 AWG)500 m (1640 ) 200 m (650 ) 100 m (330 )SEC472 4 x 0.2 mm2 Not twisted pairs (24 AWG)400 m (1310 ) 200 m (650 ) 100 m (330 )SEC4142 4 x 0.4 mm2 Not twisted pairs (21 AWG)400 m (1310 ) 200 m (650 ) 150 m (500 )* The matching of wire sizes to equivalent wire gauges are only approximate.** Recommended cable types for opmal HBUS RS485 performance.Notes:•  Shielded cable may reduce the obtainable cable length.  Shielded cable should be grounded at the Controller end only.  •  If other cable types are used, operang distances and performance may be reduced depending on the cable quality.•  HBUS allows up to 20 readers to be connected to a single cable.  Each reader requires at least 9 Vdc to funcon correctly.  The cable length and the number of readers connected will have an impact on the voltage at each reader.
Page  7   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited3 DistancebetweenreadersThe distance separang any two proximity readers must not be less than 200 mm (8 in) in all direcons.When mounng a proximity reader on an internal wall, check that any reader xed to the other side of the wall is not less than 200 mm (8 in) away.200 mm             200 mm4 InstallaonATTENTION:  This equipment contains components that can be damaged by electrostac discharge.  Ensure both you and the equipment are earthed before beginning any servicing.The Gallagher T10 Reader is designed to be mounted on any solid at surface.  However installaon on metal surfaces, parcularly those with a large surface area will reduce read range.  The extent to which the range is reduced will depend upon the type of metal surface.The recommended mounng height for the reader is 1.1 m (3.6 ) from the oor level to the centre of the reader device.  However this may vary in some countries and you should check local regulaons for variaons to this height.1.  Use the reader bezel as a guide to drill all three holes.  Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the mounng surface) and the two xing holes.2.  Run the building cabling out through the centre hole and through the reader bezel.3.  Secure the bezel to the mounng surface using the two xing screws provided.  It is important the bezel of the reader is ush with and ght against the mounng surface.Note:  It is strongly recommended that you use the screws provided.  If an alternave screw is used, the head must be no larger nor deeper than that of the screw provided.Note:  Ensure the centre hole allows the cable to run freely out through the mounng surface, so that the reader facia can clip into the bezel.
Page  8   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedBezelBuilding cableNo. 6 pan head screwNo. 6 pan head screw4.  Connect the reader tail extending from the facia assembly to the building cable.  Connect the wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV Reader, as shown.  Note:  Gallagher PIV readers must be connected as HBUS Readers.  Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only.An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (aached to a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (aached to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or a Gallagher Local Bus Reader I/O Interface.HBUS Reader connecon:      HBUS Reader terminated:Posive RedNegave BlackHBUS Terminaon OrangeHBUS A GreenHBUS B BrownCDXIV TX WhiteCDXIV RX BlueHBUS Reader Posive RedNegave BlackHBUS Terminaon OrangeHBUS A GreenHBUS B BrownCDXIV TX WhiteCDXIV RX BlueHBUS ReaderNote:  To terminate an HBUS Reader, connect the Orange (HBUS Terminaon) wire to the Green (HBUS A) wire.   Cardax IV Reader connecon:Posive RedNegave BlackHBUS Terminaon OrangeHBUS A GreenHBUS B BrownCDXIV TX WhiteCDXIV RX BlueCardax IV Reader
Page  9   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited5.  Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding the top, press the boom of the facia assembly down into the bezel.6.  Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the hole at the boom of the bezel to secure the facia assembly.  Note:  The Torx Post Security screw needs only to be lightly ghtened.Fit screw to secure facia to bezelFaciaReader tailConneconBuilding cable7.  Removal of the facia assembly is a simple reversal of these steps.8.  Congure the reader in Command Centre.  If the reader is connected as an HBUS Reader, refer to the topic "Conguring HBUS Devices" in the Command Centre Conguraon Client Online Help.  If the reader is connected as a Cardax IV Reader, refer to the topic "Creang Readers" in the Command Centre Conguraon Client Online Help.5 LEDindicaonsLED (squiggle) HBUSindicaon3 Flash (Amber) No communicaons with the Controller.2 Flash (Amber) Communicaons with the Controller, but reader is not congured.1 Flash (Amber)  Congured to a Controller, but reader is not assigned to a door or elevator car.On (Green or Red) Fully congured and funconing normally. Green  =  Access mode is Free Red      =  Access mode is SecureFlashes Green Access has been granted.Flashes Red Access has been denied.Flashes (Blue) Reading and validang a PIV card.
Page 10   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedLED (squiggle) CardaxIVindicaon3 Flash (Amber) No communicaons with the Controller.On (Green or Red) Fully congured and funconing normally. Green  =  Access mode is Free Red      =  Access mode is SecureFlashes Green Access has been granted.Flashes Red Access has been denied.6 AccessoriesAccessory Product Code Accessory Product CodeT10 Dress Plate, Black, Pk 10 C300320 T10 Spacer, Black, Pk 10 C300300T10 Bezel, Black, Pk 10 C300280 T10 Spacer, White, Pk 10 C300301T10 Bezel, White, Pk 10 C300281 T10 Protecve Cover Spacer C300310T10 Bezel, Silver, Pk 10 C300282 T10 Protecve Cover C300270T10 Bezel, Gold, Pk 10 C300283 T10 Dress Plate Black - Pack 10 C3003207 TechnicalspecicaonsRoune maintenance: Not applicable for this readerCleaning: This reader should only be cleaned with a clean, lint free, damp clothVoltage: 9 Vdc - 16 VdcCurrent: Idle 1Maximum 2at 9 Vdc 110 mA 158 mAat 13.6 Vdc 74 mA 105 mATemperature range: -35 °C to +70 °C  Note:  Direct sunlight may increase the internal reader temperature above the ambient temperature levelHumidity:   0 - 95% non-condensing 3Environmental protecon: IP68Impact rang: IK07Unit dimensions: Height 115 mm (4.5 inches) Width 35 mm (1.4 inches) Depth 12 mm (0.5 inches)Maximum number of readers on one HBUS cable:201  The reader is idle.2  Peak current during card read.3  Gallagher T Series readers are UL humidity tested and cered to 85% and have been independently veried to 95%.Note:  The current values stated above have been reported using the default conguraon for a reader in Command Centre.  Changing the conguraon may vary the current value.
Page  11   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited8  Approvals and standardsThis symbol on the product or its packaging indicates that this product must not be disposed of with other waste.  Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collecon point for the recycling of waste electrical and electronic equipment.  The separate collecon and recycling of your waste equipment at the me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment.  For more informaon about where you can drop o your waste equipment for recycling, please contact your local city recycling oce or the dealer from whom you purchased the product.FCC This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operaon.Note:  Changes or modicaons not expressly approved by Gallagher Limited could void the user's authority to operate this equipment.Note:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons.  However, there is no guarantee that interference will not occur in a parcular installaon.  If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna. •  Increase the separaon between the equipment and receiver.•  Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.IndustryCanadaThis device complies with Industry Canada licence-exempt RSS standard(s).  Operaon is subject to the following two condions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operaon of the device.Industrie CanadaLe présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.  L'exploitaon est autorisée aux deux condions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.ETSI EN 300 330-2 V1.5.1:2011 EN50130-4:2011                   Please refer to the document “3E2793 Gallagher Command Centre UL Conguraon Requirements” for a guide to conguring the Gallagher system to the appropriate UL Standard.US - Equipment: com, burg and acc reader CA - Equipment: com, burg reader
Page  12   3E4288 Gallagher T10 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited9 MounngdimensionsIMPORTANT This picture is not to scale, therefore use the measurements provided.115 mm (4.53")35 mm (1.38")44 mm (1.73") 40 mm (1.57")13 mm (1/2") diameter hole for cable22.5 mm (0.89")40 mm (1.57")

Navigation menu