Gallagher Group C30042X Prox Readers T11 Mifare and T12 Mifare User Manual 3E2513 Gallagher T11 Reader Ins Note R10 indd
Gallagher Group Ltd Prox Readers T11 Mifare and T12 Mifare 3E2513 Gallagher T11 Reader Ins Note R10 indd
Contents
- 1. Users Manual T12
- 2. Users Manual T11
Users Manual T11
InstallaƟon Note Gallagher T11 Reader ATTENTION: This equipment contains components that can be damaged by electrosta c discharge. Ensure both you and the equipment are earthed before beginning any servicing. The Gallagher T11 Reader The Gallagher T11 Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on a ver cal, rectangular 50 mm x 75 mm (2” x 3”) flush box with moun ng holes spaced at a nominal 85 mm (3.25”). The Mifare reader reads: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards. The Mul Tech reader reads: Mifare DESFire EV1, Mifare Plus, Mifare Classic and 125 kHz cards. The reader sends informa on to the Gallagher Controller and acts upon informa on sent from the Gallagher Controller. The reader itself does not make any access decisions. The Gallagher T11 Reader uses the “Cardax IV Reader” communica ons protocol to communicate with the Gallagher Controller. Note: A French transla on of this document can be downloaded from the Gallagher Support Site: hƩp://support.gallagher.co IMPORTANT: Gallagher T11 MulƟ Tech readers only: Using dual technology 125/Mifare cards with Gallagher T11 Mul Tech readers may cause both card technologies to be read, resul ng in double card badges and unusual reader feedback. Gallagher strongly recommends against using dual technology 125/Mifare cards with Gallagher Mul Tech readers for sites running pre-Command Centre v7.00 so ware (due for release 2nd half, 2011). From Command Centre v7.00, a site may specify which technology a Mul Tech reader should read off a dual technology card. Part Number: 3E2513 | Edi on 10 November 2012 Page 1 Gallagher T11 Reader Installa on Note Before you begin Shipment Contents Check the shipment contains the following items: • • • • • • 1 x Gallagher T11 Reader facia assembly 1 x Gallagher T11 Reader base 1 x M3 Torx Post Security screw 2 x 6-32 UNC Phillips drive fixing screws 4 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws 4 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws Power Supply The Gallagher T11 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The opera ng current draw is dependant on the supply voltage at the reader. For the Mifare reader at 12 Vdc the current draw is 90 mA (standby). During card read, beeper and LED ac vity, the current will momentarily reach 125 mA (peak). For the Mul Tech reader at 12 Vdc the current draw is 90 mA (standby) and will momentarily reach 140 mA (peak). The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be affected by a low quality, noisy power supply. Cabling The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered. Although the reader is specified to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc. Examples of approved cables for connec ng a single Gallagher T11 Reader to a Controller and power supply, showing maximum cable lengths for each type of cable and the associated circuits are: Manufacturer reference Page 2 Cable format* Combined power and data in a single cable Data only in a single cable CAT5E 4 twisted pair Each 2 x 0.2 mm2 (24 AWG) 100 m (330 ) 300 m (1000 ) SEC472 4 x 0.2 mm2 Not twisted pairs (24 AWG) 100 m (330 ) 250 m (800 ) SEC4142 4 x 0.4 mm2 Not twisted pairs (21 AWG) 150 m (500 ) 150 m (500 ) BELDEN 8723 2 twisted pair Each 2 x 0.4 mm2 (22 AWG) 100 m (330 ) 150 m (500 ) BELDEN 9842 2 twisted pair Each 2 x 0.2 mm2 (24 AWG) 100 m (330 ) 200 m (650 ) Edi on 10 | Part Number: 3E2513 November 2012 Gallagher T11 Reader Installa on Note * The matching of wire sizes to equivalent wire gauges are only approximate. Grounding shielded cable may reduce the obtainable cable length by 25% to 30%. Distance between Proximity Readers The distance separa ng any two proximity readers must not be less than 200 mm (8 inches) in all direc ons. 200 mm When moun ng a proximity reader on an internal wall, check that any reader fixed to the other side of the wall is not less than 200 mm (8 inches) away. 200 mm InstallaƟon The Gallagher T11 Reader is designed to be mounted on ver cally orientated electrical flush (gang) boxes, or any solid flat surface. However installa on on metal surfaces, par cularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal used. The recommended moun ng height for the reader is 1.1 m (3.6 ) from the floor level to the centre of the reader device. However this may vary in some countries and you should check local regula ons for varia ons to this height. 1. Ensure the building cable has been run out through the flush box. If you are not moun ng to a flush box, use the drill template at the back of this installa on note as a guide, to drill all five holes. Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the moun ng surface) and the four fixing holes. 2. Run the building cabling through the reader base. 3. Secure the base to the flush box using the two 6-32 UNC screws provided. It is important the base of the reader is flush with and ght against the moun ng surface. Part Number: 3E2513 | Edi on 10 November 2012 Page 3 Gallagher T11 Reader Installa on Note If you are not moun ng to a flush box, secure the base to the moun ng surface using the four fixing screws provided. Base 6-32 UNC screw Building cable 6-32 UNC screw 4. Connect the reader tail extending from the facia assembly to the building cable. Connect the wires shown below. Cardax IV Reader Note: Do not cut the ‘Reserved’ wires, as these may be used for future func ons. Posi ve Nega ve Reserved Reserved Reserved CDXIV TX CDXIV RX Red Black Orange Green Brown White Blue 5. Fit the facia assembly into the base by clipping the small lip, into the top of the base and holding the top, press the bo om of the facia assembly down into the base. 6. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the hole at the bo om of the base to secure the facia assembly. Note: The Torx security screw needs only to be lightly ghtened. The recommended torque for the security screw is 0.7 Nm (0.5 lb/ ). It is important not to exceed the maximum torque of 1.5 Nm (1.1 lb/ ). Page 4 Edi on 10 | Part Number: 3E2513 November 2012 Gallagher T11 Reader Installa on Note Facia Reader tail Connec on Fit screw to secure facia to base 7. Removal of the facia assembly is a simple reversal of these steps. ConnecƟons A Gallagher T11 Reader can connect to one of the following devices using the “Cardax IV Reader” communica ons protocol: • • • • • Gallagher Reader Module (for the Controller 6000) Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI) Gallagher Controller 3000-4R or 3000-8R Gallagher Universal Reader Interface (Gallagher URI) Gallagher Reader I/O Interface Part Number: 3E2513 | Edi on 10 November 2012 Page 5 Gallagher T11 Reader Installa on Note Cardax IV Reader 1 Nega ve Posi ve Reserved Reserved Reserved CDXIV RX CDXIV TX Black Red Orange Green Brown Blue White Cardax IV Reader 2 Nega ve Posi ve Reserved Reserved Reserved CDXIV RX CDXIV TX Black Red Orange Green Brown Blue White R2 Out R2 In R1 Out R1 In ConnecƟng to the Gallagher Reader Module (for the Controller 6000) Connect the wires to the sockets as shown: Gallagher Reader Module ConnecƟng to the Gallagher GBUS Universal Reader Interface Connect the wires to the sockets as shown in either of the following diagrams: Cardax IV Reader Cardax IV Reader Edi on 10 | Part Number: 3E2513 November 2012 GND GND VOUT GND TAMPER COM B COM A OUT Red Black Orange Green Brown White Blue OUT Top Row Pin 1 Posi ve Nega ve Reserved Reserved Reserved CDXIV TX CDXIV RX DATA 1 DATA 0 RLY 2 NC RLY 2 NO RLY 2 COM GND VIN GND VOUT GND TAMPER COM B COM A OUT Reader Pin 15 Red Black Orange Green Brown White Blue OUT Top Row Pin 1 Posi ve Nega ve Reserved Reserved Reserved CDXIV TX CDXIV RX DATA 0 RLY 2 NC RLY 2 NO RLY 2 COM DATA 1 Reader Pin 15 Page 6 Gallagher GBUS URI VIN Gallagher GBUS URI Gallagher T11 Reader Installa on Note ConnecƟng to the Gallagher Controller 3000-4R or 3000-8R The ports to which the Gallagher T11 Reader can connect are set up as groups, as follows: • • Two groups (numbered 1 and 2) on the Controller 3000-4R, and Four groups (numbered 1 to 4) on the Controller 3000-8R 0V P1 POWER IN P1 VIN COMA P3 P4 RS485 SW OPEN P4 COMB Each group provides connec on for two Gallagher T11 Readers. Refer to the following diagram for the loca on of the ports on the Gallagher Controller 3000-8R. P2 J1 to J4 RS485 terminating resistors J4 J1 J2 J3 DETECTOR 0V VOUT DATA0 DATA1 (c)2002 CARDAX (INTERNATIONAL) LTD HAMILTON, NEW ZEALAND 0V VOUT DATA0 COMA OUT1 DATA1 IN1 COMB OUT2 IN1 Group 4 pin 1 = Input 1 pin 2 = Ground pin 3 = Input 2 0V PA1 PA1 POWER OUT PC1 Group 1 VOUT DATA0 COMA OUT1 DATA1 PB1 CDX PCB 22920 V0 GGL PCB 2M8170-0 GGL ASSY 2A0203 0V VOUT DATA0 DATA1 IN1 COMB OUT2 COMA OUT1 IN1 COMB OUT2 GND IN2 IN1 IN4 GND NO COIL PC1 to PC4 Inputs PC1 Group 3 Group 2 PA2 PA2 POWER OUT PC2 PB2 NC GND IN2 IN1 IN4 GND NO COIL NC PA3 PA3 POWER OUT PC2 PD1 PD1 PB1 to PB4 2 x Cardax IV Readers per connector PA1 to PA4 Power Out pin 1 = power out pin 2 = 0 V Reader 1 = pins 1 & 3 Reader 2 = pins 2 & 4 Pin Pin Pin Pin Part Number: 3E2513 | Edi on 10 November 2012 PB3 COMB OUT2 COMA OUT1 GND PC3 PD2 NC NO COMM NC COM NO COIL COMM NC NO COM PE1 PA4 PA4 POWER OUT PC3 PD2 PF1 IN2 IN4 GND NO COIL PD3 NC NO COMM NC COM NO COIL COMM NC NO COM PE2 IN1 PC4 PD3 PF2 PB4 NC NC NO COMM NC COM NO COIL COMM NO NC COM PE3 GND IN2 IN1 PC4 PD4 PF3 IN4 GND PD4 NO COIL NC NC NO PE4 COMM NC COM NO COIL COMM NC NO COM LED PF4 Reader Reader Reader Reader transmit transmit receive receive Page 7 Gallagher T11 Reader Installa on Note Make the connec ons from the Gallagher T11 Reader to either the Gallagher Controller 3000-4R or 3000-8R as shown: Gallagher Controller 3000-4R or 3000-8R Group PB2 and PA2 (3000-4R) PB4 and PA4 (3000-8R) PA Red Black Orange Green Brown White Blue Red Black Orange Green Brown White Blue Posi ve Nega ve Reserved Reserved Reserved CDXIV TX CDXIV RX Posi ve Nega ve Reserved Reserved Reserved CDXIV TX CDXIV RX OUT 2 OUT 1 DATA 1 DATA 0 PB 2 0V 1 V OUT PB1 and PA1... to... Cardax IV Reader Cardax IV Reader Note: Within each group, you cannot mix Cardax IV Readers with Wiegand Readers. This is because connec ng one Wiegand Reader requires all four pins on plug PB. For example, if you connect a Cardax IV Reader to Port 1 of Group 1, Port 2 of Group 1 can only connect to another Cardax IV Reader. Page 8 Edi on 10 | Part Number: 3E2513 November 2012 Gallagher T11 Reader Installa on Note Technical SpecificaƟons Technical SpecificaƟons Rou ne maintenance: Not applicable for this reader. Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth. Power required: Voltage: 9 Vdc - 16 Vdc Current (at 12 Vdc): 90 mA (standby) Mifare reader 125 mA (peak) Mifare reader 90 mA (standby) Mul Tech reader 140 mA (peak) Mul Tech reader Environmental: Temperature Range: -35 °C to +70 °C Note: Direct sunlight may increase the internal reader temperature above the ambient temperature level. Humidity: 95% non-condensing Environmental Protec on: IP68 Impact Ra ng: IK07 Approvals and Standards This product complies with the environmental regula ons for the Restric on of Hazardous Substances in electrical and electronic equipment (RoHS). The RoHS direc ve prohibits the use of electronic equipment containing certain hazardous substances in the European Union. This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collec on point for the recycling of waste electrical and electronic equipment. The separate collec on and recycling of your waste equipment at the me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more informa on about where you can drop off your waste equipment for recycling, please contact your local city recycling office or the dealer from whom you purchased the product. ACN 002 132 943 Part Number: 3E2513 | Edi on 10 November 2012 Page 9 Gallagher T11 Reader FCC Installa on Note This device complies with part 15 of the FCC Rules. Opera on is subject to the following two condi ons: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera on. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons, may cause harmful interference to radio communica ons. However, there is no guarantee that interference will not occur in a par cular installa on. If this equipment does cause harmful interference to radio or television recep on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separa on between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Industry Canada This device complies with Industry Canada licence-exempt RSS standard(s). Opera on is subject to the following two condi ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired opera on of the device. Note: Changes or modifica ons not expressly approved by Gallagher Group Limited could void the user’s authority to operate this equipment. Page 10 Edi on 10 | Part Number: 3E2513 November 2012 32 mm (1.26 inches) 22.5 mm (0.89 inches) 40 mm (1.57 inches) 70 mm (2.76 inches) 115 mm (4.53 inches) 13 mm (1/2 inch) diameter hole for cable 40 mm (1.57 inches) 48 mm (1.89 inches) Drill Template
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : traceyr Create Date : 2012:11:02 11:15:35+13:00 Modify Date : 2012:11:02 11:15:35+13:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.0.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : 3E2513 Gallagher T11 Reader - Ins Note R10.indd Creator : traceyr Document ID : uuid:460178a1-2eab-4453-a49f-ec3ef36fcf2d Instance ID : uuid:eadd86ca-ad52-44f7-be85-7580a9b7ffdd Page Count : 11EXIF Metadata provided by EXIF.tools