Gallagher Group C30042X Prox Readers T11 Mifare and T12 Mifare User Manual 3E2512 Gallagher T12 Reader Ins Note R11 indd

Gallagher Group Ltd Prox Readers T11 Mifare and T12 Mifare 3E2512 Gallagher T12 Reader Ins Note R11 indd

Contents

Users Manual T12

Download: Gallagher Group C30042X Prox Readers T11 Mifare and T12 Mifare User Manual 3E2512 Gallagher T12 Reader   Ins Note R11 indd
Mirror Download [FCC.gov]Gallagher Group C30042X Prox Readers T11 Mifare and T12 Mifare User Manual 3E2512 Gallagher T12 Reader   Ins Note R11 indd
Document ID1847250
Application IDcVgJ8BwRnyHj/yc8C4pXCg==
Document DescriptionUsers Manual T12
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize22.44kB (280473 bits)
Date Submitted2012-11-28 00:00:00
Date Available2012-11-28 00:00:00
Creation Date2012-11-02 11:18:29
Producing SoftwareAcrobat Distiller 10.0.0 (Windows)
Document Lastmod2012-11-02 11:18:29
Document Title3E2512 Gallagher T12 Reader - Ins Note R11.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: traceyr

InstallaƟon Note
Gallagher T12 Reader
ATTENTION: This equipment contains components that can be damaged
by electrosta c discharge. Ensure both you and the equipment are earthed
before beginning any servicing.
The Gallagher T12 Reader
The Gallagher T12 Reader is a smart card proximity reader. It can be installed
as either an entry reader or exit reader. It can be mounted on a BS 4662 Bri sh
Standard square flush box.
The Mifare reader reads: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards.
The Mul Tech reader reads: Mifare DESFire EV1, Mifare Plus, Mifare Classic and
125 kHz cards.
The reader sends informa on to the Gallagher Controller and acts upon informa on
sent from the Gallagher Controller. The reader itself does not make any access
decisions.
The Gallagher T12 Reader uses the “Cardax IV Reader” communica ons protocol to
communicate with the Gallagher Controller.
Note: A French transla on of this document can be downloaded from the Gallagher
Support Site: hƩp://support.gallagher.co
IMPORTANT: Gallagher T12 MulƟ Tech readers only:
Using dual technology 125/Mifare cards with Gallagher T12 Mul Tech readers
may cause both card technologies to be read, resul ng in double card badges
and unusual reader feedback. Gallagher strongly recommends against using dual
technology 125/Mifare cards with Gallagher Mul Tech readers for sites running
pre-Command Centre v7.00 so ware (due for release 2nd half, 2011). From
Command Centre v7.00, a site may specify which technology a Mul Tech reader
should read off a dual technology card.
Part Number: 3E2512 | Edi on 11
November 2012
Page 1
Gallagher T12 Reader
Installa on Note
Before you begin
Shipment Contents
Check the shipment contains the following items:
•
•
•
•
•
•
1 x Gallagher T12 Reader facia assembly
1 x Gallagher T12 Reader base
1 x M3 Torx Post Security screw
2 x M3.5 Phillips drive fixing screws
4 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws
4 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws
Power Supply
The Gallagher T12 Reader is designed to operate over a supply voltage range
of 9 - 16 Vdc measured at the reader terminals. The opera ng current draw is
dependant on the supply voltage at the reader. For the Mifare reader at 12 Vdc the
current draw is 90 mA (standby). During card read, beeper and LED ac vity, the
current will momentarily reach 125 mA (peak). For the Mul Tech reader at 12 Vdc
the current draw is 90 mA (standby) and will momentarily reach 140 mA (peak).
The power source should be linear or a good quality switched-mode power supply.
The performance of the reader may be affected by a low quality, noisy power supply.
Cabling
The Gallagher T12 Reader requires a minimum cable size of 4 core 24 AWG
(0.2 mm2) stranded security cable. This cable allows the transmission of data
(2 wires) and power (2 wires). When using a single cable to carry both power
supply and data, both the power supply voltage drop and data requirements must
be considered. Although the reader is specified to operate at 9 Vdc, for good
engineering design it is recommended that the voltage at the reader should be
approximately 12 Vdc.
Examples of approved cables for connec ng a single Gallagher T12 Reader to a
Controller and power supply, showing maximum cable lengths for each type of cable
and the associated circuits are:
Manufacturer
reference
Page 2
Cable format*
Combined
power and data
in a single cable
Data only in a
single cable
CAT5E
4 twisted pair
Each 2 x 0.2 mm2 (24 AWG)
100 m (330 )
300 m (1000 )
SEC472
4 x 0.2 mm2
Not twisted pairs (24 AWG)
100 m (330 )
250 m (800 )
SEC4142
4 x 0.4 mm2
Not twisted pairs (21 AWG)
150 m (500 )
150 m (500 )
BELDEN 8723
2 twisted pair
Each 2 x 0.4 mm2 (22 AWG)
100 m (330 )
150 m (500 )
BELDEN 9842
2 twisted pair
Each 2 x 0.2 mm2 (24 AWG)
100 m (330 )
200 m (650 )
Edi on 11 | Part Number: 3E2512
November 2012
Gallagher T12 Reader
Installa on Note
* The matching of wire sizes to equivalent wire gauges are only approximate.
Grounding shielded cable may reduce the obtainable cable length by 25% to 30%.
Distance between Proximity Readers
The distance separa ng any two proximity readers must not be less than 200 mm
(8 inches) in all direc ons.
200 mm
When moun ng a proximity reader on an internal wall, check that any reader fixed
to the other side of the wall is not less than 200 mm (8 inches) away.
200
mm
InstallaƟon
The Gallagher T12 Reader is designed to be mounted on a standard Bri sh electrical
flush box, or any solid flat surface. However installa on on metal surfaces,
par cularly those with a large surface area will reduce read range. The extent to
which the range is reduced will depend upon the type of metal used.
The recommended moun ng height for the reader is 1.1 m (3.6 ) from the floor
level to the centre of the reader device. However this may vary in some countries
and you should check local regula ons for varia ons to this height.
1.
Ensure the building cable has been run out through the flush box.
If you are not moun ng to a flush box, use the drill template at the back of this
installa on note as a guide, to drill all five holes. Drill the 13 mm (1/2 inch)
diameter centre hole (this is the centre hole for which the building cable will
exit the moun ng surface) and the four fixing holes.
2.
Run the building cabling through the reader base.
3.
Secure the base to the flush box using the two M3.5 screws provided. It is
important the base of the reader is flush with and ght against the moun ng
surface.
Part Number: 3E2512 | Edi on 11
November 2012
Page 3
Gallagher T12 Reader
Installa on Note
If you are not moun ng to a flush box, secure the base to the moun ng
surface using the four fixing screws provided.
Base
Building
cable
M3.5 screw
M3.5 screw
4.
Connect the reader tail extending from the facia assembly to the building
cable. Connect the wires shown below.
Cardax IV Reader
Note: Do not cut the ‘Reserved’ wires, as these may be used for future
func ons.
Posi ve
Nega ve
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
5.
Fit the facia assembly into the base by clipping the small lip, into the top of the
base and holding the top, press the bo om of the facia assembly down into
the base.
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security
screwdriver) through the hole at the bo om of the base to secure the facia
assembly.
Note: The Torx security screw needs only to be lightly ghtened.
The recommended torque for the security screw is 0.7 Nm (0.5 lb/ ).
It is important not to exceed the maximum torque of 1.5 Nm (1.1 lb/ ).
Page 4
Edi on 11 | Part Number: 3E2512
November 2012
Gallagher T12 Reader
Installa on Note
Facia
Reader tail
Connec on
7.
Fit screw to secure
facia to base
Removal of the facia assembly is a simple reversal of these steps.
ConnecƟons
A Gallagher T12 Reader can connect to one of the following devices using the
“Cardax IV Reader” communica ons protocol:
•
•
•
•
•
Gallagher Reader Module (for the Controller 6000)
Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI)
Gallagher Controller 3000-4R or 3000-8R
Gallagher Universal Reader Interface (Gallagher URI)
Gallagher Reader I/O Interface
Part Number: 3E2512 | Edi on 11
November 2012
Page 5
Gallagher T12 Reader
Installa on Note
Cardax IV Reader 1
Nega ve
Posi ve
Reserved
Reserved
Reserved
CDXIV RX
CDXIV TX
Black
Red
Orange
Green
Brown
Blue
White
Cardax IV Reader 2
Nega ve
Posi ve
Reserved
Reserved
Reserved
CDXIV RX
CDXIV TX
Black
Red
Orange
Green
Brown
Blue
White
R2 Out
R2 In
R1 Out
R1 In
ConnecƟng to the Gallagher Reader Module (for the Controller 6000)
Connect the wires to the sockets as shown:
Gallagher Reader Module
ConnecƟng to the Gallagher GBUS Universal Reader Interface
Connect the wires to the sockets as shown in either of the following diagrams:
Cardax IV Reader
Cardax IV Reader
Edi on 11 | Part Number: 3E2512
November 2012
GND
GND
VOUT
GND
TAMPER
COM B
COM A
OUT
Red
Black
Orange
Green
Brown
White
Blue
OUT
Top Row
Pin 1
Posi ve
Nega ve
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
DATA 1
DATA 0
RLY 2 NC
RLY 2 NO
RLY 2 COM
GND
VIN
GND
VOUT
GND
TAMPER
COM B
COM A
OUT
Reader
Pin 15
Red
Black
Orange
Green
Brown
White
Blue
OUT
Top Row
Pin 1
Posi ve
Nega ve
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
DATA 0
RLY 2 NC
RLY 2 NO
RLY 2 COM
DATA 1
Reader
Pin 15
Page 6
Gallagher GBUS URI
VIN
Gallagher GBUS URI
Gallagher T12 Reader
Installa on Note
ConnecƟng to the Gallagher Controller 3000-4R or 3000-8R
The ports to which the Gallagher T12 Reader can connect are set up as groups, as
follows:
•
•
Two groups (numbered 1 and 2) on the Controller 3000-4R, and
Four groups (numbered 1 to 4) on the Controller 3000-8R
0V
P1
POWER
IN P1
VIN
COMA
P3
P4
RS485
SW
OPEN
P4
COMB
Each group provides connec on for two Gallagher T12 Readers. Refer to the
following diagram for the loca on of the ports on the Gallagher Controller 3000-8R.
P2
J1 to J4 RS485
terminating resistors
J4
J1
J2
J3
DETECTOR
0V
VOUT
DATA0
DATA1
(c)2002 CARDAX (INTERNATIONAL) LTD
HAMILTON, NEW ZEALAND
0V
VOUT
DATA0
COMA
OUT1
DATA1
IN1
COMB
OUT2
IN1
Group 4
pin 1 = Input 1
pin 2 = Ground
pin 3 = Input 2
0V
PA1
PA1
POWER
OUT
PC1
Group 1
VOUT
DATA0
COMA
OUT1
DATA1
PB1
CDX PCB 22920 V0
GGL PCB 2M8170-0
GGL ASSY 2A0203
0V
VOUT
DATA0
DATA1
IN1
COMB
OUT2
COMA
OUT1
IN1
COMB
OUT2
GND
IN2
IN1
IN4
GND
NO
COIL
PC1 to PC4
Inputs
PC1
Group 3
Group 2
PA2
PA2
POWER
OUT
PC2
PB2
NC
GND
IN2
IN1
IN4
GND
NO
COIL
NC
PA3
PA3
POWER
OUT
PC2
PD1
PD1
PB1 to PB4
2 x Cardax IV Readers
per connector
PA1 to PA4
Power Out
pin 1 = power out
pin 2 = 0 V
Reader 1 = pins 1 & 3
Reader 2 = pins 2 & 4
Pin
Pin
Pin
Pin
Part Number: 3E2512 | Edi on 11
November 2012
PB3
COMB
OUT2
COMA
OUT1
GND
PC3
PD2
NC
NO
COMM
NC
COM
NO
COIL
COMM
NC
NO
COM
PE1
PA4
PA4
POWER
OUT
PC3
PD2
PF1
IN2
IN4
GND
NO
COIL
PD3
NC
NO
COMM
NC
COM
NO
COIL
COMM
NC
NO
COM
PE2
IN1
PC4
PD3
PF2
PB4
NC
NC
NO
COMM
NC
COM
NO
COIL
COMM
NO
NC
COM
PE3
GND
IN2
IN1
PC4
PD4
PF3
IN4
GND
PD4
NO
COIL
NC
NC
NO
PE4
COMM
NC
COM
NO
COIL
COMM
NC
NO
COM
LED
PF4
Reader
Reader
Reader
Reader
transmit
transmit
receive
receive
Page 7
Gallagher T12 Reader
Installa on Note
Make the connec ons from the Gallagher T12 Reader to either the Gallagher
Controller 3000-4R or 3000-8R as shown:
Gallagher Controller 3000-4R or 3000-8R
Group
PB2 and PA2 (3000-4R)
PB4 and PA4 (3000-8R)
PA
Red
Black
Orange
Green
Brown
White
Blue
Red
Black
Orange
Green
Brown
White
Blue
Posi ve
Nega ve
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Posi ve
Nega ve
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
OUT 2
OUT 1
DATA 1
DATA 0
PB
2 0V
1 V OUT
PB1 and PA1... to...
Cardax IV Reader
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV Readers with Wiegand Readers.
This is because connec ng one Wiegand Reader requires all four pins on plug PB.
For example, if you connect a Cardax IV Reader to Port 1 of Group 1, Port 2 of Group
1 can only connect to another Cardax IV Reader.
Page 8
Edi on 11 | Part Number: 3E2512
November 2012
Gallagher T12 Reader
Installa on Note
Technical SpecificaƟons
Technical SpecificaƟons
Rou ne maintenance:
Not applicable for this reader.
Cleaning:
This reader should only be cleaned with a clean, lint free,
damp cloth.
Power required:
Voltage: 9 Vdc - 16 Vdc
Current (at 12 Vdc): 90 mA (standby) Mifare reader
125 mA (peak) Mifare reader
90 mA (standby) Mul Tech reader
140 mA (peak) Mul Tech reader
Environmental:
Temperature Range: -35 °C to +70 °C
Note: Direct sunlight may increase the internal reader
temperature above the ambient temperature level.
Humidity: 95% non-condensing
Environmental Protec on: IP68
Impact Ra ng: IK07
Approvals and Standards
This product complies with the environmental regula ons for the
Restric on of Hazardous Substances in electrical and electronic
equipment (RoHS). The RoHS direc ve prohibits the use of
electronic equipment containing certain hazardous substances in
the European Union.
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it
is your responsibility to dispose of your waste equipment by
handing it over to a designated collec on point for the recycling
of waste electrical and electronic equipment. The separate
collec on and recycling of your waste equipment at the me of
disposal will help conserve natural resources and ensure that
it is recycled in a manner that protects human health and the
environment. For more informa on about where you can drop
off your waste equipment for recycling, please contact your local
city recycling office or the dealer from whom you purchased the
product.
ACN 002 132 943
Part Number: 3E2512 | Edi on 11
November 2012
Page 9
Gallagher T12 Reader
FCC
Installa on Note
This device complies with part 15 of the FCC Rules. Opera on
is subject to the following two condi ons: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired opera on.
Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protec on against harmful interference in a
residen al installa on. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruc ons, may cause harmful interference
to radio communica ons. However, there is no guarantee that
interference will not occur in a par cular installa on. If this
equipment does cause harmful interference to radio or television
recep on, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separa on between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
Industry
Canada
This device complies with Industry Canada licence-exempt RSS
standard(s). Opera on is subject to the following two condi ons:
(1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may
cause undesired opera on of the device.
Note: Changes or modifica ons not expressly approved by
Gallagher Group Limited could void the user’s authority to
operate this equipment.
Page 10
Edi on 11 | Part Number: 3E2512
November 2012
Drill Template
10 mm
(0.39 inches)
86 mm (3.39 inches)
13 mm (1/2 inch)
diameter hole for
cable
22.3 mm
(0.88 inches)
26 mm (1 inch)
29 mm (1.14 inches)
30 mm
(1.18 inches)
40 mm (1.57 inches)
35 mm (1.38 inches)
25 mm (1 inch)
86 mm (3.39 inches)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : traceyr
Create Date                     : 2012:11:02 11:18:29+13:00
Modify Date                     : 2012:11:02 11:18:29+13:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : 3E2512 Gallagher T12 Reader - Ins Note R11.indd
Creator                         : traceyr
Document ID                     : uuid:29cd2ce5-75c4-4ba8-b947-60d1b17e3c5a
Instance ID                     : uuid:bfd155c4-b9a8-4b78-ba1d-b13e2010b6ab
Page Count                      : 11
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M5VC30042X

Navigation menu