Gallagher Group C30044XA Prox Readers T11 Multi Tech, T11 Multi Tech PIV and T12 Multi Tech User Manual

Gallagher Group Ltd Prox Readers T11 Multi Tech, T11 Multi Tech PIV and T12 Multi Tech Users Manual

Contents

Users Manual

Download: Gallagher Group C30044XA Prox Readers T11 Multi Tech, T11 Multi Tech PIV and T12 Multi Tech User Manual
Mirror Download [FCC.gov]Gallagher Group C30044XA Prox Readers T11 Multi Tech, T11 Multi Tech PIV and T12 Multi Tech User Manual
Document ID3138847
Application IDOUmWVZWiIejIAzDl7Zq9fw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.12kB (464007 bits)
Date Submitted2016-09-20 00:00:00
Date Available2016-09-21 00:00:00
Creation Date2016-08-23 12:05:13
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-08-23 12:05:15
Document TitleUsers Manual
Document CreatorAdobe InDesign CC 2015 (Windows)

Gallagher
T11 Reader
Installation Note
T11 Mifare Reader Black: C300410
T11 Mifare Reader White: C300411
T11 Multi Tech Reader Black: C300430
T11 Multi Tech Reader White: C300431
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
T11 PIV Reader Black: C305410
T11 PIV Reader White: C305411
T11 PIV Reader - Multi Tech Black: C305430
T11 PIV Reader - Multi Tech White: C305431
Page 1
Disclaimer
This document gives certain information about products and/or services provided by Gallagher Group Limited
or its related companies (referred to as "Gallagher Group").
The information is indicative only and is subject to change without notice meaning it may be out of date at any
given time. Although every commercially reasonable effort has been taken to ensure the quality and accuracy
of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should
not be relied on as such. To the extent permitted by law, all express or implied, or other representations or
warranties in relation to the information are expressly excluded.
Neither Gallagher Group nor any of its directors, employees or other representatives shall be responsible
for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the
information provided.
Except where stated otherwise, the information is subject to copyright owned by Gallagher Group and you may
not sell it without permission. Gallagher Group is the owner of all trademarks reproduced in this information.
All trademarks which are not the property of Gallagher Group, are acknowledged.
Copyright © Gallagher Group Ltd 2016. All rights reserved.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 2
Contents
Introduction...................................................................................................................................... 4
Before you begin............................................................................................................................... 5
Distance between readers................................................................................................................ 7
Installation........................................................................................................................................ 8
LED indications................................................................................................................................ 10
Accessories..................................................................................................................................... 10
Technical specifications................................................................................................................... 11
Approvals and standards................................................................................................................. 12
Mounting dimensions..................................................................................................................... 13
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 3
1
Introduction
The Gallagher T11 Reader is a mobile credential and smart card proximity reader. It can be installed as
either an entry reader or exit reader. It can be mounted on a vertical, rectangular 50 mm x 75 mm (2" x
3") flush box with mounting holes spaced at a nominal 85 mm (3.25").
The reader sends information to the Gallagher Controller and acts upon information sent from the
Gallagher Controller. The reader itself does not make any access decisions.
The reader is available in eight variants. The card technologies for each variant are shown below.
Reader
Product codes
Supported card technologies
T11 Mifare Reader Black
T11 Mifare Reader White
C300410
C300411
Mifare DESFire EV1, Mifare Plus and
Mifare Classic
T11 Multi Tech Reader Black
T11 Multi Tech Reader White
C300430
C300431
Mifare DESFire EV1, Mifare Plus, Mifare
Classic and 125 KHz cards
T11 PIV Reader Black
T11 PIV Reader White
C305410
C305411
PIV, PIV-I, Mifare DESFire EV1, Mifare
Plus and Mifare Classic
T11 PIV Reader - Multi Tech Black
T11 PIV Reader - Multi Tech White
C305430
C305431
PIV, PIV-I, Mifare DESFire EV1, Mifare
Plus, Mifare Classic and 125 KHz cards
The reader can be connected as an HBUS Reader or Cardax IV Reader. An HBUS Reader uses the HBUS
communications protocol to communicate with the Gallagher Controller. A Cardax IV Reader uses the
Cardax IV Reader communications protocol to communicate with the Gallagher Controller.
IMPORTANT: HBUS compatibility
HBUS communications are supported with sites running Gallagher Command Centre vEL7.00 software
(or later).
IMPORTANT: Multi Tech readers
Using dual technology 125/Mifare cards with Gallagher Multi Tech readers may cause both card
technologies to be read, resulting in double card badges and unusual reader feedback. Gallagher
strongly recommends against using dual technology 125/Mifare cards with Multi Tech readers for sites
running pre-Command Centre v7.00 software. From Command Centre v7.00, a site may specify which
technology a Multi Tech reader should read off a dual technology card.
IMPORTANT: PIV readers
Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only (referred
to as the Controller). Gallagher PIV readers can only be used with sites running Gallagher Command
Centre vEL7.10 software (or later). Gallagher PIV readers are connected as HBUS Readers only.
IMPORTANT: Mobile credential readers
Gallagher Multi Tech readers support Gallagher mobile credentials using Bluetooth® wireless
technology. Mobile credentials are supported with sites running Gallagher Command Centre vEL7.60
software (or later). To use mobile credentials, the Multi Tech reader must be connected as an HBUS
Reader.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 4
2
Before you begin
2.1
Shipment contents
Check the shipment contains the following items:
2.2
•
1 x Gallagher T11 Reader facia assembly
•
1 x Gallagher T11 Reader bezel
•
1 x M3 Torx Post Security screw
•
2 x 6-32 UNC Phillips drive fixing screws
•
4 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws
•
4 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws
Power supply
The Gallagher T11 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc
measured at the reader terminals. The operating current draw is dependant on the supply
voltage at the reader. For the Mifare reader, at 13.6 Vdc the current draw is 84 mA (idle). During
card read, beeper and LED activity, the current will momentarily reach 113 mA (maximum). For
the Multi Tech reader, at 13.6 Vdc the current draw is 100 mA (idle) and will momentarily reach
124 mA (maximum). The power source should be linear or a good quality switched-mode power
supply. The performance of the reader may be affected by a low quality, noisy power supply.
2.3
Cabling
The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded
security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When
using a single cable to carry both power supply and data, both the power supply voltage drop
and data requirements must be considered. Although the reader is specified to operate at 9
Vdc, for good engineering design it is recommended that the voltage at the reader should be
approximately 12 Vdc.
HBUS cabling topology
The HBUS communications protocol is based on the RS485 standard and allows the reader to
communicate over a distance of up to 500 m (1640 ft).
The cabling between HBUS devices should be done in a "daisy chain" topology, (i.e. A "T" or
"Star" topology should not be used between devices). Should "Star" or "Home-Run" wiring be
required, the HBUS 4H/8H Modules and the HBUS Door Module allow multiple HBUS devices to
be individually wired to the one physical location.
The end devices on the HBUS cable should be terminated using 120 ohms resistance. To
terminate the Gallagher Controller 6000, connect the supplied on-board termination jumpers
to the Controller. To terminate a reader, connect the orange (termination) wire to the green
(HBUS A) wire. Termination is already included at the HBUS Module, (i.e. each HBUS port is
permanently terminated at the module).
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 5
"T" or "Star" circuits are
not permitted between
HBUS devices
HBUS
Device
HBUS
Device
HBUS
Device
HBUS
Device
HBUS
Device
Controller 6000
Connect the on-board
termination jumper
Terminate
HBUS
Device
HBUS
Device
RS485 1
HBUS
Device
"T" or "Star" circuits are
not permitted between
HBUS devices
RS485 1
HBUS
Device
Controller 6000
Terminate
Remove the on-board
termination jumper
Terminate
HBUS
Device
HBUS
Device
"T" or "Star" circuits are
not permitted between
HBUS devices
Controller 6000
HBUS
Device
H1
H5
HBUS
Device
H4
H8
HBUS
Device
HBUS Module
Terminate
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
HBUS
Device
Terminate
HBUS
Device
HBUS
Device
Terminate
Terminate
Page 6
Cable distance
Cable type
Cable format*
CAT 5e or
better**
HBUS
single reader
connected using
data only in a
single cable
Cardax IV
single reader
connected using
data only in a
single cable***
HBUS/Cardax IV
single reader
connected using
power and data
in a single cable
4 twisted pair
500 m (1640 ft)
Each 2 x 0.2 mm2
(24 AWG)
200 m (650 ft)
100 m (330 ft)
BELDEN 9842** 2 twisted pair
500 m (1640 ft)
(shielded)
Each 2 x 0.2 mm2
(24 AWG)
200 m (650 ft)
100 m (330 ft)
SEC472
4 x 0.2 mm2
Not twisted
pairs (24 AWG)
400 m (1310 ft)
200 m (650 ft)
100 m (330 ft)
SEC4142
4 x 0.4 mm2
Not twisted
pairs (21 AWG)
400 m (1310 ft)
200 m (650 ft)
150 m (500 ft)
* The matching of wire sizes to equivalent wire gauges are only approximate.
** Recommended cable types for optimal HBUS RS485 performance.
*** Not applicable for PIV or Gallagher mobile credential reader installations.
Notes:
•
Shielded cable may reduce the obtainable cable length. Shielded cable should be
grounded at the Controller end only.
•
If other cable types are used, operating distances and performance may be reduced
depending on the cable quality.
•
HBUS allows up to 20 readers to be connected to a single cable. Each reader requires at
least 9 Vdc to function correctly. The cable length and the number of readers connected
will have an impact on the voltage at each reader.
Distance between readers
The distance separating any two proximity readers must not be less than 200 mm (8 in) in all directions.
When mounting a proximity reader on an internal wall, check that any reader fixed to the other side of
the wall is not less than 200 mm (8 in) away.
200 mm
200
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
mm
Page 7
4
Installation
ATTENTION: This equipment contains components that can be damaged by
electrostatic discharge. Ensure both you and the equipment are earthed before
beginning any servicing.
The Gallagher T11 Reader is designed to be mounted on vertically orientated electrical flush (gang)
boxes, or any solid flat surface. However installation on metal surfaces, particularly those with a large
surface area will reduce read range. The extent to which the range is reduced will depend upon the
type of metal surface.
Note: Consideration should be given to the installation environment when using Gallagher mobile
credentials, as the Bluetooth® wireless technology read range may be reduced.
The recommended mounting height for the reader is 1.1 m (3.6 ft) from the floor level to the centre of
the reader device. However this may vary in some countries and you should check local regulations for
variations to this height.
1.
Ensure the building cable has been run out through the flush box.
If you are not mounting to a flush box, use the reader bezel as a guide to drill all five holes. Drill
the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable
will exit the mounting surface) and the four fixing holes.
2.
Run the building cabling out through the centre hole and through the reader bezel.
3.
Secure the bezel to the flush box using the two 6-32 UNC screws provided. It is important the
reader bezel is flush with and tight against the mounting surface.
If you are not mounting to a flush box, secure the bezel to the mounting surface using the four
fixing screws provided.
Note: It is strongly recommended that you use the screws provided. If an alternative screw is
used, the head must be no larger nor deeper than that of the screw provided.
Note: Ensure the centre hole allows the cable to run freely out through the mounting surface, so
that the reader facia can clip into the bezel.
6-32 UNC screw
Bezel
Building cable
6-32 UNC screw
4.
Connect the reader tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
Reader, as shown in the following diagrams.
Note: Gallagher PIV and mobile credential readers must be connected as HBUS Readers.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 8
Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only.
An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to
a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached
to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher
Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or
a Gallagher Local Bus Reader I/O Interface.
Positive
Negative
HBUS Termination
HBUS A
HBUS B
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
HBUS Reader terminated:
HBUS Reader
HBUS Reader
HBUS Reader connection:			
Positive
Negative
HBUS Termination
HBUS A
HBUS B
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
Note: To terminate an HBUS Reader, connect the Orange (HBUS Termination) wire to the Green
(HBUS A) wire.		
Cardax IV Reader
Cardax IV Reader connection:
Positive
Negative
HBUS Termination
HBUS A
HBUS B
CDXIV TX
CDXIV RX
Red
Black
Orange
Green
Brown
White
Blue
5.
Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding
the top, press the bottom of the facia assembly down into the bezel.
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole at the bottom of the bezel to secure the facia assembly.
Note: The Torx Post Security screw needs only to be lightly tightened.
Reader tail
Facia
Building cable
Connection
Fit screw to secure facia to bezel
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 9
5
7.
Removal of the facia assembly is a simple reversal of these steps.
8.
Configure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to
the topic "Configuring HBUS Devices" in the Command Centre Configuration Client Online Help.
If the reader is connected as a Cardax IV Reader, refer to the topic "Creating Readers" in the
Command Centre Configuration Client Online Help.
LED indications
LED (squiggle)
HBUS indication
3 Flash (Amber)
No communications with the Controller.
2 Flash (Amber)
Communications with the Controller, but reader is not configured.
1 Flash (Amber)
Configured to a Controller, but reader is not assigned to a door or elevator car.
On (Green or Red)
Fully configured and functioning normally.
Green = Access mode is Free
Red = Access mode is Secure
Flashes Green
Access has been granted.
Flashes Red
Access has been denied.
Flashes (Blue)
Reading and validating a PIV card. Reading a Gallagher mobile credential.
LED (squiggle)
Cardax IV indication
3 Flash (Amber)
No communications with the Controller.
On (Green or Red)
Fully configured and functioning normally.
Green = Access mode is Free
Red = Access mode is Secure
Flashes Green
Access has been granted.
Flashes Red
Access has been denied.
Accessories
Accessory
Product Code
T11 Dress Plate, Black, Pk 10
C300321
T11 Bezel, Black, Pk 10
C300284
T11 Bezel, White, Pk 10
C300285
T11 Bezel, Silver, Pk 10
C300286
T11 Bezel, Gold, Pk 10
C300287
T11 Spacer, Black, Pk 10
C300302
T11 Spacer, White, Pk 10
C300303
T11/T12 Protective Cover Spacer
C300311
T11/T12 Protective Cover
C300271
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 10
7
Technical specifications
Routine maintenance:
Not applicable for this reader
Cleaning:
This reader should only be cleaned with a clean, lint free, damp cloth
Voltage:
9 Vdc - 16 Vdc
Current:
Mifare Reader
Idle
Maximum
Multi Tech Reader
Idle 1
Maximum 2
at 9 Vdc
124 mA
175 mA
115 mA
164 mA
at 13.6 Vdc
84 mA
113 mA
100 mA
124 mA
Temperature range:
-35 °C to +70 °C
Note: Direct sunlight may increase the internal reader temperature
above the ambient temperature level
Humidity:
0 - 95% non-condensing 3
Environmental protection:
IP68
Impact rating:
IK07
Unit dimensions:
Height 115 mm (4.5")
Width 70 mm (2.8")
Depth 12 mm (0.5")
Maximum number of readers
on one HBUS cable:
20
The reader is idle.
Peak current during card read.
Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently
verified to 95%.
Note: The current values stated above have been reported using the default configuration for a reader
in Command Centre. Changing the configuration may vary the current value.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 11
8
Approvals and standards
This symbol on the product or its packaging indicates that this product must not be disposed
of with other waste. Instead, it is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the recycling of waste electrical and electronic
equipment. The separate collection and recycling of your waste equipment at the time of disposal
will help conserve natural resources and ensure that it is recycled in a manner that protects human
health and the environment. For more information about where you can drop off your waste
equipment for recycling, please contact your local city recycling office or the dealer from whom
you purchased the product.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Note: Changes or modifications not expressly approved by Gallagher Limited could void the user's
authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Industry
Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Industrie
Canada
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
ETSI EN 300 330-2 V1.5.1:2011
EN50130-4:2011
US - Equipment: com, burg and acc reader
CA - Equipment: com, burg reader
Please refer to the document “3E2793 Gallagher Command Centre UL Configuration Requirements” for a guide
to configuring the Gallagher system to the appropriate UL Standard.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 12
9
Mounting dimensions
Mifare Card
read area
32 mm (1.26")
115 mm (4.53")
40 mm (1.57")
48 mm (1.89")
13 mm (1/2")
diameter hole for cable
22.5 mm
(0.89")
125 Card
read area
40 mm (1.57")
70 mm (2.76")
IMPORTANT
This picture is not to scale, therefore use the measurements provided.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Page 13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Instance ID                     : uuid:a85d4e2b-7b46-4752-a711-0c0b1ca69dcc
Original Document ID            : adobe:docid:indd:f96526b2-a0ce-11df-8595-adfd5648a1ab
Document ID                     : xmp.id:7ddaeda4-9801-5d44-a618-3505c87ecb96
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:a94b175f-7481-4740-b1d8-f3a02b9236ca
Derived From Document ID        : adobe:docid:indd:f96526b2-a0ce-11df-8595-adfd5648a1ab
Derived From Original Document ID: adobe:docid:indd:f96526b2-a0ce-11df-8595-adfd5648a1ab
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:08:23 12:05:13+12:00
Create Date                     : 2016:08:23 12:05:13+12:00
Modify Date                     : 2016:08:23 12:05:15+12:00
Metadata Date                   : 2016:08:23 12:05:15+12:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 13
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M5VC30044XA

Navigation menu