Gateway Alr 9200 Users Manual Server
ALR 9200 to the manual fdf05998-94a7-43e0-860f-6de2e50cf6ff
2015-02-02
: Gateway Gateway-Alr-9200-Users-Manual-403176 gateway-alr-9200-users-manual-403176 gateway pdf
Open the PDF directly: View PDF
.
Page Count: 226
| Download | |
| Open PDF In Browser | View PDF |
3424.boo Page i Wednesday, September 2, 1998 9:23 AM Maintaining and Troubleshooting the Gateway ALR 9200 Server Part # 8503424 A MAN SYS US 9200 TECH REF R0 8/98 In our effort to use nature’s resources efficiently and wisely, we print all manuals on recycled papers that meet the minimum requirements established by the Federal EPA in its guidelines for recycled paper products. 3424.boo Page ii Wednesday, September 2, 1998 9:23 AM Notices Copyright © 1998 Gateway 2000, Inc. All Rights Reserved 610 Gateway Drive N. Sioux City, SD 57049 USA All Rights Reserved This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any means or in any form, without prior consent in writing from Gateway 2000. The information in this manual has been carefully checked and is believed to be accurate. However, changes are made periodically. These changes are incorporated in newer publication editions. Gateway 2000 may improve and/or change products described in this publication at any time. Due to continuing system improvements, Gateway 2000 is not responsible for inaccurate information which may appear in this manual. For the latest product updates, consult the Gateway 2000 web site at www.gateway.com. In no event will Gateway 2000 be liable for direct, indirect, special, exemplary, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. In the interest of continued product development, Gateway 2000 reserves the right to make improvements in this manual and the products it describes at any time, without notices or obligation. Trademark Acknowledgments AnyKey, black-and-white spot design, CrystalScan, Destination, EZ Pad, EZ Point, Field Mouse, Solo, TelePath, Vivitron, stylized “G” design, and “You’ve got a friend in the business” slogan are registered trademarks and GATEWAY, Gateway Solo, green stylized GATEWAY, green stylized Gateway logo, and the black-and-white spotted box logo are trademarks of Gateway 2000, Inc. Intel, Intel Inside logo, and Pentium are registered trademarks and MMX is a trademark of Intel Corporation. Microsoft, MS, MS-DOS, and Windows are trademarks or registered trademarks of Microsoft Corporation. All other product names mentioned herein are used for identification purposes only, and may be the trademarks or registered trademarks of their respective companies. Copyright © 1998 Advanced Logic Research, Inc. (ALR) All Rights Reserved 9401 Jeronimo Irvine, CA 92618 USA All Rights Reserved This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any means or in any form, without prior consent in writing from ALR. The information in this manual has been carefully checked and is believed to be accurate. However, changes are made periodically. These changes are incorporated in newer publication editions. ALR may improve and/or change products described in this publication at any time. Due to continuing system improvements, ALR is not responsible for inaccurate information which may appear in this manual. For the latest product updates, consult the ALR web site at www.alr.com. In no event will ALR be liable for direct, indirect, special, exemplary, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. In the interest of continued product development, ALR reserves the right to make improvements in this manual and the products it describes at any time, without notices or obligation. Trademark Acknowledgments ALR is a registered trademark of Advanced Logic Research, Inc. All other product names mentioned herein are used for identification purposes only, and may be the trademarks or registered trademarks of their respective companies. Some portions of this document are copyright © 1998, Intel Corporation. 3424.boo Page i Wednesday, September 2, 1998 9:23 AM Contents Preface .....................................................................................vii About This Guide ................................................................................ viii Conventions Used in This Guide........................................................... ix Important Safety Instructions.................................................................. x Chapter 1: System Access ....................................................... 1 Static Electricity Precautions .................................................................. 2 Opening the System ................................................................................ 3 Removing the Access Cover............................................................ 3 Opening the Front Door ................................................................... 4 Opening the Subchassis and Electronics Bay ................................. 5 Closing the System.................................................................................. 7 Closing the Subchassis and Electronics Bay................................... 7 Installing the Access Cover.............................................................. 8 Installing the Front Door.................................................................. 8 Chapter 2: Components ........................................................... 9 System Board Features.......................................................................... 10 System Board Connectors..................................................................... 10 Drive Controllers and Connectors ................................................. 12 System Jumpers (B) ....................................................................... 13 Miscellaneous Connectors............................................................. 14 Expansion Slot Connectors............................................................ 15 Memory Module Connector (I) ..................................................... 16 System Management Connectors.................................................. 16 Back Panel I/O Connectors............................................................ 18 Processors and Related Connectors............................................... 20 Power Connectors .......................................................................... 21 Memory.................................................................................................. 23 DIMM Installation Sequence......................................................... 24 System Memory Addressing ......................................................... 24 Memory Configuration .................................................................. 25 System Security..................................................................................... 26 Mechanical Locks and Monitoring................................................ 26 Software Locks via the SSU or BIOS Setup ................................. 26 Contents i 3424.boo Page ii Wednesday, September 2, 1998 9:23 AM Chapter 3: Installing Components ...........................................31 Introduction........................................................................................... 32 Replacing the Processor........................................................................ 32 Installing Another Processor ................................................................ 36 Installing Hardware............................................................................... 40 Memory.......................................................................................... 40 Drives ............................................................................................. 45 Installing Fans for High-Power Drives......................................... 57 Expansion Cards ............................................................................ 62 Power Supplies .............................................................................. 65 Replacing the Battery .................................................................... 68 Chapter 4: Jumpers and Drivers .............................................71 Setting the Jumpers............................................................................... Changing a Jumper Setting............................................................ CMOS Clear Jumper ..................................................................... Password Clear Jumper ................................................................. Recovery Boot Jumper .................................................................. Installing Software and Drivers............................................................ Installing Video Drivers ................................................................ 72 73 74 75 75 77 77 Chapter 5: BIOS Setup ...........................................................79 Introduction........................................................................................... 80 Using BIOS Setup................................................................................. 81 Record Your Setup Settings .......................................................... 81 If You Cannot Access Setup ......................................................... 82 Starting Setup................................................................................. 82 Setup Menus.......................................................................................... 83 Setup Key Commands................................................................... 84 Special Display Items .................................................................... 84 Main Menu..................................................................................... 85 Advanced Menu............................................................................. 87 Security Menu................................................................................ 92 Server Menu................................................................................... 93 Boot Menu...................................................................................... 95 Exit Menu....................................................................................... 97 ii Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page iii Wednesday, September 2, 1998 9:23 AM Upgrading the BIOS.............................................................................. 98 Preparing for the Upgrade.............................................................. 98 Upgrading the BIOS..................................................................... 100 Recovering the BIOS ................................................................... 101 Changing the BIOS Language..................................................... 101 Chapter 6: The Server Setup Utility ....................................... 103 Introduction.......................................................................................... 104 Using the System Setup Utility........................................................... 105 When to Run the SSU .................................................................. 105 What You Need to Do.................................................................. 106 Running the SSU................................................................................. 107 Running the SSU Locally ............................................................ 107 Running the SSU Remotely......................................................... 107 Starting the SSU ........................................................................... 108 Customizing the SSU .......................................................................... 109 Launching a Task ................................................................................ 111 Resource Configuration Add-in Window .......................................... 112 Using the RCA Window.............................................................. 112 Defining an ISA Board................................................................. 113 Adding and Removing ISA Boards............................................. 114 Modifying Resources................................................................... 114 System Resource Usage............................................................... 115 Multiboot Options Add-in................................................................... 115 Security Add-in ................................................................................... 116 Security Options........................................................................... 117 System Event Log Viewer Add-in...................................................... 118 Sensor Data Record Manager Add-In.................................................................................................. 120 Field Replaceable Unit Manager Add-In ........................................... 122 Exiting the SSU ................................................................................... 124 Chapter 7: Other Utilities ....................................................... 125 Introduction.......................................................................................... 126 Power-on Self Test .............................................................................. 127 Emergency Management Port Console.............................................. 129 How the EMP Console Works..................................................... 130 EMP Console Requirements........................................................ 132 Contents iii 3424.boo Page iv Wednesday, September 2, 1998 9:23 AM Setting Up the Server for the EMP.............................................. 133 Main EMP Console Window...................................................... 134 Server Control Operations........................................................... 136 Phonebook.................................................................................... 140 Management Plug-ins.................................................................. 141 FRU and SDR Load Utility ................................................................ 145 When to Run the FRUSDR Load Utility.................................... 145 What You Need to Do ................................................................. 145 How You Use the FRUSDR Load Utility .................................. 146 Cleaning Up and Exiting ............................................................. 150 Using the Firmware Update Utility.................................................... 151 Running the Firmware Update Utility ........................................ 151 Using the Symbios SCSI Utility......................................................... 152 Running the SCSI Utility............................................................. 152 Chapter 8: Troubleshooting ..................................................153 Introduction......................................................................................... 154 Computer Virus Notice....................................................................... 155 Viruses.......................................................................................... 155 Types of Viruses .......................................................................... 155 Virus Contamination.................................................................... 155 Protecting Your System............................................................... 156 Virus Prevention .......................................................................... 156 Troubleshooting Checklist ................................................................. 158 Verifying the Configuration ........................................................ 158 Troubleshooting Guidelines........................................................ 158 Solving Problems................................................................................ 159 Resetting the System.................................................................... 159 Initial System Startup................................................................... 159 Running New Application Software........................................... 160 The System Has Been Running Correctly.................................. 161 More Problem-solving Procedures ............................................. 162 Specific Problems and Corrective Actions................................. 164 Error and Informational Messages..................................................... 170 POST Codes and Countdown Codes .......................................... 170 POST Error Codes and Messages ............................................... 173 iv Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page v Wednesday, September 2, 1998 9:23 AM Appendix A: Reference Data ................................................ 175 Specifications....................................................................................... 176 System Specifications .................................................................. 176 Environmental Specifications...................................................... 177 System I/O Addresses ......................................................................... 178 Memory Map....................................................................................... 181 Interrupts.............................................................................................. 182 Video Modes ....................................................................................... 183 DMA Usage......................................................................................... 187 Appendix B: Regulatory Compliance Statements ................ 189 Electromagnetic Compatibility........................................................... 190 FCC Notice.......................................................................................... 191 Industry Canada Notice....................................................................... 192 CE Notice............................................................................................. 192 VCCI Notice........................................................................................ 193 Australia/New Zealand Notice ........................................................... 193 Declaration of the Manufacturer or Importer ..................................... 194 Safety Compliance .............................................................................. 194 Index ..................................................................................... 195 Contents v 3424.boo Page vi Wednesday, September 2, 1998 9:23 AM vi Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page vii Wednesday, September 2, 1998 9:23 AM Preface Contents About This Guide ................................................. viii Conventions Used in This Guide ........................... ix Important Safety Instructions.................................. x 3424.boo Page viii Wednesday, September 2, 1998 9:23 AM About This Guide This document provides step-by-step installation instructions along with detailed illustrations to help maintain the hardware components and peripherals of the computer. Chapter 1: System Access provides instructions on opening and closing the case. Chapter 2: Components covers information on maintaining, replacing, and upgrading the components in the system. This section includes information about options for the system and installation instructions. Chapter 3: Installing Components describes the procedures for installing or replacing the hardware components. Chapter 4: Jumpers and Drivers describes setting the jumpers and provides basic information about operating systems and software. Chapter 5: BIOS Setup briefly explains the system basic input/output system (BIOS) and provides instructions on how to update the BIOS. Chapter 6: The Server Setup Utility describes the system setup utility and provides instructions on using it to set up the server. Chapter 7: Other Utilities describes the other utilities provided with the system and provides instructions for their use. Chapter 8: Troubleshooting provides reference material on troubleshooting your system. viii Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page ix Wednesday, September 2, 1998 9:23 AM Conventions Used in This Guide Throughout this document, you will see the following conventions: Convention Description ENTER Key names, which correspond to keys on the keyboard, are printed in small capitals. CTRL+ALT+DEL A plus sign indicates that the keys must be pressed simultaneously. Setup Commands to be entered, options to select, and messages that appear on your monitor are printed in bold. User’s Guide Names of publications and files are printed in italic. Sidebars Sidebars give critical information such as warnings and important notes. Note: This is an example of an important note that may appear in the manual. Conventions Used in This Guide ix 3424.boo Page x Wednesday, September 2, 1998 9:23 AM Important Safety Instructions Warning! Do not attempt to service the system yourself except as explained elsewhere in the manual. Adjust only those controls covered in the instructions. Opening or removing covers marked “Do Not Remove” may expose you to dangerous voltages or other risks. Refer all servicing of those compartments to qualified service personnel. Observe the following guidelines when performing any work on your system: • Follow all instructions marked on the server and in the documentation. • Unplug this product from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning. • Do not use this product near water. Do not spill liquid on or into the server. • • Do not place the server on an unstable surface. • Use only the power source shown on the power supply. If you are not certain about the power source, ask the local power company. • The server is equipped with a 3-wire grounding plug (a plug with a grounding pin). This plug only fits into a grounded power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace the outlet. • • Do not walk on the power cord or allow anything to rest on it. • • Never insert objects of any kind into the system ventilation slots. Important! The system power cord serves as the main disconnect for the computer. The wall outlet must be easily accessible by the operator. x Openings in the system cabinet are provided for ventilation. Do not block or cover these openings. Do not place the server near or upon a radiator or heat register. If you use an extension cord with this system, make sure the total ampere ratings on the products plugged into the extension cord do not exceed the extension cord ampere rating. Also, the total ampere requirements for all products plugged into the wall outlet must not exceed 15 amperes. Unplug the system from the wall outlet and refer servicing to qualified personnel if: • The power cord or plug is damaged. • Liquid has been spilled into the system. • The system does not operate properly when the operating instructions are followed. • The system was dropped or the cabinet is damaged. • The system’s performance changes. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 1 Wednesday, September 2, 1998 9:23 AM Chapter 1: System Access Contents Static Electricity Precautions .................................. 2 Opening the System................................................. 3 Removing the Access Cover............................ 3 Opening the Front Door ................................... 4 Opening the Subchassis and Electronics Bay . 5 Closing the System .................................................. 7 Closing the Subchassis and Electronics Bay... 7 Installing the Access Cover.............................. 8 Installing the Front Door .................................. 8 3424.boo Page 2 Wednesday, September 2, 1998 9:23 AM Static Electricity Precautions Caution! Prevent Static-Electricity Damage Static Electricity Preventions 1. 2. 3. 4. 5. WEAR A GROUNDING WRIST STRAP (available at most electronic stores). Turn off the system power. Touch the back of the power supply fan, located on the back of the case. UNPLUG ALL CORDS FROM WALL OUTLET. Remove the system case cover. Static Electricity Precautions ♦ ♦ ♦ ♦ 2 Avoid static-causing surfaces such as plastic and styrofoam in your work area. Remove the parts from their antistatic bags only when you are ready to use them. Do not lay parts on the outside of antistatic bags since only the inside provides antistatic protection. Always hold cards by their edges and their metal mounting bracket. Avoid touching components on the cards and the edge connectors that connect to expansion slots. Never slide cards or other parts over any surface. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 3 Wednesday, September 2, 1998 9:23 AM Opening the System Depending on your purpose, you may need to remove the access cover or both the access cover and the bezel. You may also need to open the subchassis or the electronics bay to reach certain components. Follow the instructions specific to the item you wish to remove or open as indicated in each section. Removing the Access Cover You need to remove the system access cover to reach components inside the system. Facing the front of the system, the access cover is on the right side of the server. Caution! Power the system off and disconnect all power cords before proceeding. Installing any component while the power is on may cause permanent damage to the system. To Remove the Access Cover 1. Observe the ESD precautions in “Static Electricity Precautions” on page 2. 2. Turn off all peripheral devices connected to the system. 3. Turn off the system by using the power on/off switch on the front panel and unplugging all AC power cords. 4. Label and disconnect all peripheral cables attached to the input/output (I/O) panel on the back of the system. Opening the System 3 3424.boo Page 4 Wednesday, September 2, 1998 9:23 AM 5. Remove and save the three screws from the back of the access cover (see Figure 1); you will need them later to reattach the cover. Figure 1: Removing the Access Cover 6. Place the fingertips of your right hand under the built-in handle on the back of the cover. A rounded, rectangular depression in the front middle of the access cover serves as another handle. 7. Using an even pull, slide the cover backward, about an inch, until it stops. 8. Pull the entire cover outward, straight away from the chassis, to disengage the rows of tabs from the notches in the top and bottom edges of the chassis. Set the cover aside. Opening the Front Door The front door is secured to the bezel by a key lock. This lock has three positions: fully locked, front door unlocked, and front and access cover unlocked. When the front door is unlocked, you can remove it by opening it fully and lifting the hinges out of the slots that hold them. 4 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 5 Wednesday, September 2, 1998 9:23 AM Opening the Subchassis and Electronics Bay The chassis is comprised of three parts: the main chassis, a swing-out subchassis at the front, and a swing-out subchassis, called the electronics bay, at the rear. To access components in some instances, you must remove the foam covers and swing away and/or completely remove the subchassis and electronics bay. To open the subchassis and electronics bay, you must first remove the foam covers. The subchassis and electronics bays are secured using phillips head screws. To Open the Subchassis and Electronics Bay 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Turn off all peripheral devices connected to the system. 3. Turn off the system power by using the power on/off switch on the front panel and unplugging all AC power cords. 4. Label and disconnect all peripheral cables attached to the I/O panel on the back of the system. 5. Remove and save the three screws from the back of the access cover; you will need them later to reattach the cover. 6. Remove the access cover. 7. Remove the foam blocks by pulling them out of the subchassis and electronics bay. These blocks form an important part of the airflow and electromotive compatibility (EMC) characteristics of the system. The foam in the subchassis also forms the support structure for most of the system fans. Opening the System 5 3424.boo Page 6 Wednesday, September 2, 1998 9:23 AM 8. Loosen the two screws on the top and bottom edges of the chassis (A Caution! You must disconnect all cabling to the electronics bay before rotating/ removing the bay. Failure to do so can result in serious damage to system components. The location of the main connectors in the electronics bay is marked as D in Figure 2. in Figure 2). These screws attach the front subchassis and the electronics bay to the main chassis. A B C D Figure 2: Opening the Subchassis and Electronics Bay 9. Using the edges of the subchassis as handles, rotate the front Note: It may be easier to disconnect the cables if you remove the foam pad first. subchassis left, away from the main chassis, until it stops (B in Figure 2). 10. Disconnect all cabling to the electronics bay (D in Figure 2). 11. Using the vertical edge of the electronics bay as a handle, rotate the bay right, away from the main chassis, until it stops (C in Figure 2). 12. If necessary, completely remove the subchassis and electronics bay: rotate the bays outward until the two pins that function as hinges for the bays slide out of their slots. Set the bays aside. 6 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 7 Wednesday, September 2, 1998 9:23 AM Closing the System Before closing the system, verify that all connectors and boards are properly installed and firmly seated. Closing the Subchassis and Electronics Bay As you close the subchassis and electronics bay, carefully observe the internal components to ensure that you do not pinch or twist any of the cables or components. To Close the Subchassis and Electronics Bay 1. Verify that all internal components are fully installed and secured. 2. Press down on the tab on the top of the electronics bay to release it and swing it closed. 3. Attach any cables to the electronics bay components. 4. Press down on the tab at the top of the subchassis to free it and swing it closed. 5. Secure the subchassis with the two screws you removed earlier. 6. If necessary, reinstall the foam bracketing for the fans in the subchassis and reinstall the fans. 7. Reinstall the foam over the subchassis and electronics bay. 8. Replace the access cover and power up the system. Closing the System 7 3424.boo Page 8 Wednesday, September 2, 1998 9:23 AM Installing the Access Cover Note: The bezel key lock must be in the open position before reinstalling the access cover. Be careful to avoid pinching any internal cables in the access cover when closing the system. To Replace the Access Cover 1. Before replacing the access cover, check that you have not left loose tools or parts inside the system. 2. Check that cables, expansion cards, foam pad, and other components are properly installed. 3. Position the cover over the chassis so that the rows of tabs align with slots in the chassis. While pressing inward, slide the cover toward the front of the system until the tabs on the cover firmly engage in the chassis. 4. Attach the cover to the chassis with the three screws you removed earlier, and tighten them firmly. 5. Connect all external cables and the power cords to the system. Installing the Front Door To replace the front door, insert the hinges into the slots on the front of the chassis and close the door. Secure it by turning the bezel keylock to the second locked position. The first position allows you to open the front door and locks the side access panel. The fully locked position prevents all access to the system controls by locking both the access panel and the bezel door. 8 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 9 Wednesday, September 2, 1998 9:23 AM Chapter 2: Components Contents System Board Features...................................................10 System Board Connectors..............................................10 Drive Controllers and Connectors..........................12 System Jumpers (B)................................................13 Miscellaneous Connectors......................................14 Expansion Slot Connectors ....................................15 Memory Module Connector (I)..............................16 System Management Connectors...........................16 Back Panel I/O Connectors ....................................18 Processors and Related Connectors .......................20 Power Connectors...................................................21 Memory...........................................................................23 DIMM Installation Sequence .................................24 System Memory Addressing..................................24 Memory Configuration...........................................25 System Security ..............................................................26 Mechanical Locks and Monitoring ........................26 Software Locks via the SSU or BIOS Setup..........26 3424.boo Page 10 Wednesday, September 2, 1998 9:23 AM System Board Features The system board functions as the main interface between the processor, memory, and peripherals. Table 1 lists the features of the system board. Figure 3 on page 11 shows the components on the system board and their locations. Table 1: System Board Features Feature Description Processor Installed: Up to four Pentium® II Xeon™ processors, in single edge contact (SEC) cartridges installed in Slot 2 connectors. Includes connectors for six VRM 8.3-compliant plug-in voltageregulator modules (VRMs). Main memory Single plug-in module containing 16 dual in-line memory module (DIMM) sockets for up to 4 GB of extended data output (EDO) dynamic random access memory (DRAM). Installed: 256 MB–4 GB of EDO error correcting code (ECC) random access memory (RAM). Video memory Installed: 2 MB of video memory. PCI bus(es) PCI-A—Three expansion connectors PCI-B—Four expansion connectors (one shared with the ISA slot) ISA bus One expansion slot for expansion boards (shared with a PCI-B slot). Server management Thermal/voltage monitoring and error handling. Front panel controls and indicator light emitting diodes (LEDs). Graphics Integrated onboard Cirrus Logic GD5480 super video graphics array (SVGA) controller. SCSI Two embedded small computer systems interface (SCSI) controllers: Symbios SYM53C810AE—narrow SCSI controller providing support for legacy 8-bit SCSI devices Symbios SYM53C896—dual-channel wide low voltage differential (LVD)/single-ended (SE) (ultra2/ultra) SCSI controller driving one SCSI backplane in the system and providing support for external expansion. System I/O PS/2-compatible keyboard and mouse ports, parallel port, video port, USB port, and two serial ports (serial port 1 is the left connector). System Board Connectors Figure 3 shows the connectors on the system board. Some of these connectors may not be used, depending on the configuration of the server. The table below provides the key to Figure 3. 10 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 11 Wednesday, September 2, 1998 9:23 AM A B CD E F G LL JJ KK II H HH I GG FF EE CC AA Z DD BB P Y Q J K L R X W V S M T N O U Figure 3: System Board Components and Connectors A Wide SCSI B connector (J9J1) T VRM connector for processors 2 & 1 (J4A2) B System jumpers (J6J1) U VRM connector for processor 1 (J4A1) C Hard drive input LED connector (J6J3) V Processor 1 Slot 2 connector (J9A1) D System speaker connector (J6J2) W Main power connector, primary (J9B1) E Lithium battery (B4H1) X Processor 2 Slot 2 connector (J9B2) F Wake-on-LAN technology connector (J4H1) Y Processor 3 Slot 2 connector (J9D1) G ISA slot (J1J1) Z Main power connector, secondary (J9D2) H PCI slots B4 (top), B3, B2, B1, A3, and A2 AA Front panel connector (J8E1) I Memory module connector (J3G1) BB Processor 4 Slot 2 connector (J9E1) J ICMB connector (J1E1) CC IDE connector (J9E2) K PCI slot A1 (J2D1) DD Diskette drive connector (J9E3) L Video and parallel port connectors (J1C1) EE Auxiliary power connector (J9E4) M Serial port connectors (J1B2) FF USB internal header (JC9F14) N Keyboard and mouse connectors (J1B1) GG SMBus connector (J9F2) O USB external connector (J1A1) HH F16 expansion connector (J7G1) P VRM connector for processor 4 (J4E1) II Narrow SCSI connector (J9H1) Q VRM connector for processors 4 & 3 (J4C2) JJ External IPMB connector (J7H1) R VRM connector for processor 3 (J4C1) KK SMM connector (J8H1) S VRM connector for processor 2 (J4B1) LL Wide SCSI A connector (J9H2) System Board Connectors 11 3424.boo Page 12 Wednesday, September 2, 1998 9:23 AM Drive Controllers and Connectors The system board supports several controllers and connectors for the control of the various drives that are or can be installed in the system. SCSI Connectors The system board includes two SCSI controllers. A narrow SCSI controller (SYM53C810AE) is on the PCI-A bus, and a dual-channel wide LVD/SE (Ultra2/Ultra) SCSI controller (SYM53C896) is on the PCI-B bus. The narrow controller provides support for legacy 8-bit SCSI devices that may be installed in the 5.25-inch drive bays. The wide controller drives one SCSI backplane and provides support for external expansion. Each controller has its own set of PCI configuration registers and SCSI I/O registers. As a PCI 2.1 bus master, the wide controller supports burst data transfers on PCI up to the maximum rate of 132 MB/sec using on-chip buffers. No logic, termination, or resistor loads are required to connect devices to the SCSI controller other than termination in the device at the end of the cable. The SCSI bus is terminated on the system board with active terminators that can be disabled. Wide SCSI A (LL) and Wide SCSI B Connectors (A) Internally, each wide channel is identical, capable of operations using either 8- or 16-bit SCSI providing 10 MB/sec (Fast-10) or 20 MB/sec (Fast-20) throughput, or 20 MB/sec (Ultra) or 40 MB/sec (Ultra-wide). The wide controller contains a high-performance SCSI bus interface. It supports SE mode with 8-bit (10 or 20 MB/sec) or 16-bit (20 or 40 MB/sec) transfers and LVD mode with 8-bit (40 MB/sec) or 16-bit (80 MB/sec) transfers. Narrow SCSI Connector (II) The narrow controller contains a high-performance SCSI core capable of Fast 8-bit SCSI transfers in single-ended mode. It provides programmable active negation, PCI zero wait-state bursts of faster than 110 MB/sec at 33 MHz, and SCSI transfer rates from 5 to 10 MB/sec. 12 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 13 Wednesday, September 2, 1998 9:23 AM IDE Connector (CC) This is an integrated Ultra-DMA PCI/IDE interface with an IDE connector capable of controlling up to two IDE devices. Ultra-DMA provides faster access to IDE devices that are Ultra-DMA compliant while maintaining support for IDE devices that do not support the Ultra-DMA specification. The IDE controller supports: • • • PIO and IDE DMA/bus master operations • • • Buffering for PCI/IDE burst transfers Mode 4 timings Transfer rates up to 33 MB/sec Master/slave IDE mode Note: You can connect an IDE signal cable, up to a maximum of 18 inches, to the IDE connector on the system board. The cable can support two devices, one at the end of the cable and one six inches from the end. Up to two drives for one IDE channel Diskette Drive Connector (DD) The diskette drive controller and connector on the system board can support up to two diskette drives of 1.44-MB and 2.88-MB formats. System Jumpers (B) These jumpers allow you to set certain characteristics of the system. Some jumpers are reserved and are not described in this section. Do not change any jumper unless it is necessary to configure the system. In some cases, changing the settings of reserved jumpers can cause damage to the system board. Clear CMOS Jumper This jumper allows you to clear the complimentary metal-oxide semiconductor (CMOS) memory. You should only do this if you cannot access the normal methods of modifying the CMOS and modifications to the CMOS are necessary. Clearing CMOS memory returns all BIOS Setup settings to the default values. This jumper occupies pins 1-3 of the connector. See “Setting the Jumpers” on page 72 for more information on setting the CMOS clear jumper. System Board Connectors 13 3424.boo Page 14 Wednesday, September 2, 1998 9:23 AM Password Clear Jumper Momentarily setting this jumper allows you to clear the passwords. The normal jumper position protects the passwords. Use this jumper only if you have forgotten the passwords and cannot access the system. This jumper occupies pins 5-7 of the connector. See “Setting the Jumpers” on page 72 for more information on setting the password clear jumper. Recovery Boot Jumper The recovery boot jumper should be used only in the event of a failed BIOS update. If you attempt a BIOS update and the update fails, set this jumper and reboot the system. The system attempts to recover the previous version of the BIOS as it boots up. This jumper occupies pins 9-11 of the connector. See “Setting the Jumpers” on page 72 for more information on setting the recovery boot jumper. Miscellaneous Connectors Hard Drive Input LED Connector (C) This connector allows you to connect a cable from an add-in hard disk controller to the system board to allow the add-in controller to activate the hard drive activity LED on the control panel. System Speaker Connector (D) Connects the internal speaker to the system board. Wake-on-LAN Technology Connector (F) The wake on local area network (LAN) technology connector allows you to connect a magic packet-enabled LAN adapter to the system board to support wake on LAN functionality. Wake on LAN functionality allows a system in power conservation mode to be awakened by an incoming message on the network. 14 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 15 Wednesday, September 2, 1998 9:23 AM Front Panel Connector (AA) The front panel connector provides the signals for the front cover indicator LEDs and the front cover buttons. USB Internal Connector (FF) This connector allows you to connect internal devices that use the USB interface to the USB controller on the system board. Lithium Battery (E) Provides the power to maintain the CMOS memory when the system is turned off or unplugged. Expansion Slot Connectors ISA Slot (G) The system board has one industry standard architecture (ISA) slot that is full-length if you do not use the wide SCSI-B connector (and half-length if you use the wide SCSI-B connector); the ISA slot supports slave-only boards and is shared with PCI-B slot 4. The ISA bus also supports three embedded devices: the Super I/O chip, system board management controller (BMC), and flash memory for the system BIOS. ISA bus features: • • • • • • Bus speed up to 8.33 MHz 16-bit memory addressing Type A transfers at 5.33 MB/sec Type B transfers at 8 MB/sec 8- or 16-bit data transfers Plug and Play ready System Board Connectors 15 3424.boo Page 16 Wednesday, September 2, 1998 9:23 AM PCI slots B4 (top), B3, B2, B1, A3, A2 (H), A1 (K) The system board has two 32-bit peripheral component interconnect (PCI) bus segments: PCI-A and PCI-B. These provide seven slots for PCI expansion cards: three on PCI-A and four on PCI-B. PCI-B4 is shared with the ISA slot. PCI-A1 supports half-length boards only. The other slots support full-length boards. PCI bus features: • • • • • • • 33 MHz bus speed 32-bit memory addressing 5 V signaling environment Burst transfers of up to 133 MB/sec 8-, 16-, or 32-bit data transfers Plug and Play ready Parity enabled Memory Module Connector (I) The memory module connector supports the memory module. The memory module is a proprietary card that supports all of the main memory for the system. The memory module is described in “Memory” on page 23. System Management Connectors Server Management features are implemented using one microcontroller, the system board management controller (BMC). The BMC and associated circuitry are powered from the 5 V standby line, which remains active when the system power is switched off. The primary function of the BMC is to autonomously monitor system management events and log their occurrence in the nonvolatile system event log (SEL). These events include overtemperature and overvoltage conditions, fan failure, or chassis intrusion. While monitoring, the BMC maintains the nonvolatile sensor data record repository (SDRR), from which run-time information can be retrieved. The BMC provides an ISA 16 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 17 Wednesday, September 2, 1998 9:23 AM host interface to SDRR information, so software running on the server can poll and retrieve the current status of the hardware. A shared register interface is defined for this purpose. SEL contents can be retrieved after system failure for analysis by field service personnel using system management tools like Intel® LANDesk® Server Manager. Because the BMC is powered by 5V_Standby, SEL (and SDRR) information is also available via the interperipheral management bus (IPMB). An emergency management board like the Intel LANDesk server management module (SMM) board can obtain the SEL and make it remotely accessible using a LAN or telephone line connection. During monitoring, the BMC performs the following functions: • • System board temperature and voltage monitoring • • • • • • • • • • • System board fan failure detection and indicator control • • • • Sensor event initialization agent Processor presence monitoring and fault resilient boot (FRB) control SEL interface management SDRR interface management SDR/SEL timestamp clock System board field replaceable unit (FRU) information interface System management watchdog timer Periodic system management interrupt (SMI) timer Front panel non-maskable interrupt (NMI) handling Event receiver ISA host and IPMB interface management Secure mode control, front panel lock/unlock initiation, and video blank and diskette write protect monitoring and control Wake-on-LAN via Magic Packet support ACPI Support Emergency Management Port (EMP) support System Board Connectors 17 3424.boo Page 18 Wednesday, September 2, 1998 9:23 AM ICMB Connector (J) The intelligent chassis management bus (ICMB) connector allows the connection of a system management component to monitor the chassis characteristics including temperature, voltages, intrusion detection, and fan speeds. SMBus Connector (GG) This connector supports an SMBus card that provides system management functions. F16 Expansion Connector (HH) The F16 expansion connector allows you to connect a component to the F16 bus which communicates between the memory and I/O controller (MIOC) and the PCI expansion bridge (PXB). External IPMB connector (JJ) This connector allows you to connect an “external” device to the IPMB to help determine the cause of a system failure from a remote terminal. SMM connector (KK) The SMM connector allows you to connect a system management module to the system board to monitor the system and perform other system management functions. Back Panel I/O Connectors Video Port Connector (L) The onboard, integrated Cirrus Logic CL-GD5480 64-bit VGA chip contains an SVGA controller that is fully compatible with the VGA video standard. The system board provides 2 MB of 10 ns onboard video 18 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 19 Wednesday, September 2, 1998 9:23 AM memory. The video controller supports pixel resolutions of up to 1600 x 1200 and up to 16.7 M colors. You cannot add video memory to this system. The SVGA controller supports analog VGA monitors (single and multiple frequency, interlaced and noninterlaced) with a maximum vertical retrace noninterlaced frequency of 100 Hz. Depending on the environment, the controller displays up to 16.7 M colors in some video resolutions. Compatible video drivers are provided with the operating system or the utilities. Parallel Port Connector (L) The 25/15-pin connector stacks the parallel port beside the VGA video port. BIOS programming of the super I/O chip registers enables the parallel port and determines the port address and interrupt. The system BIOS provides fields in the setup utility to easily enable the parallel port and set the port address and interrupt. When disabled, the interrupt is available to expansion cards. Serial Port Connectors (M) Both serial ports are relocatable. By default, port 1 is the left connector, port 2 on the right. Each serial port can be set to one of four different COMx ports, and each can be enabled separately. The system BIOS provides fields in the setup utility to easily enable both serial ports and set the port addresses and interrupts. When disabled, serial port interrupts are available to expansion cards. Keyboard and Mouse Connectors (N) The PS/2-compatible keyboard and mouse connectors are mounted in a single-stacked housing with the mouse connector to the left of the keyboard. External to the system, they appear as two connectors. You can plug in the keyboard and mouse to either connector before powering up the system. BIOS detects the device connected at each connector and configures the keyboard controller accordingly. System Board Connectors 19 3424.boo Page 20 Wednesday, September 2, 1998 9:23 AM The keyboard controller is functionally compatible with the 8042A microcontroller. The system can be locked automatically if no keyboard or mouse activity occurs for a predefined length of time, if specified through the SSU. Once the inactivity (lockout) timer has expired, the keyboard and mouse do not respond until the previously stored password is entered. USB External Connector (O) Note: A second USB port internal to the system chassis is provided at position FF as shown in Figure 3 on page 11 One universal serial bus (USB) port provides connection for a growing list of peripheral components including mouse, keyboard, joystick, monitor, tape and diskette drives. Up to 127 devices can be daisy-chained from the port. The USB port also provides hot-swap capability and dynamic resource allocation for all peripherals attached to it with data transfer rates of up to 12 Mbps. USB drivers are provided as a part of most major operating systems and should require no special procedures for implementation or use. Processors and Related Connectors VRM Connectors (P, Q, R, S, T, U) In this system each processor must have one VRM to adjust the voltage supplied to the processor core and one to adjust the voltage supplied to the second-level cache in the SEC cartridge. The first VRM is dedicated to a single processor and provides the correct power to the processor core. The second VRM provides power to the integrated second-level cache and can support the cache on two SEC cartridges. Therefore each processor requires 1.5 VRMs. See Table 2 for the allowed processor and VRM configurations. Table 2: Processors and VRMs Processor Installed Processor 1 Processor 2 Processor 3 Processor 4 20 VRM Installed VRM Function VRM 1 Powers the processor core for processor 1 VRM 2 Powers the second-level cache for processors 1 and 2 VRM 3 Powers the processor core for processor 2 VRM 4 Powers the processor core for processor 3 VRM 5 Powers the second-level cache for processors 3 and 4 VRM 6 Powers the processor core for processor 4 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 21 Wednesday, September 2, 1998 9:23 AM Processor Slots (V, X, Y, AB) Each Pentium® II Xeon™ processor is packaged in a SEC cartridge. The cartridge includes the processor core with an integrated 16 KB primary (L1) cache; the secondary (L2) cache; a thermal plate; and a back cover. The processor implements MMX™ technology and maintains full backward compatibility with the 8086, 80286, Intel386™, Intel486™, Pentium, and Pentium Pro processors. Each SEC cartridge connects to the system board through a Slot 2 edge connector. The cartridge is secured by a retention bracket attached to the system board. Depending on configuration, the server has one to four processors. The processor external interface is multiprocessor (MP)-ready and operates at 100 MHz. The processor contains a local advanced programmable interrupt controller (APIC) for interrupt handling in MP and uniprocessor (UP) environments. The system SMP design supports up to four processors and is Intel MP Specification v1.1 and 1.4 compliant. The second-level cache is located inside the SEC cartridge. The cache includes burst pipelined synchronous static RAM (BSRAM) and is offered in 512 KB, 1 MB, and 2 MB configurations, with ECC that operates at the full core clock rate. Each processor cartridge requires two VRMs to provide power to the processor core and the second-level cache, respectively. The full details of the installation of processors and VRMs are provided in “VRM Connectors (P, Q, R, S, T, U)” on page 20. Power Connectors There are several power connectors that provide power for the system board. Some of these connectors provide power for specialized functions. Main Power Connector, Primary (W) The primary power connectors provide the majority of the power to the system board. These connectors are designed to accommodate the power supply installed in the system. System Board Connectors 21 3424.boo Page 22 Wednesday, September 2, 1998 9:23 AM Main Power Connector, Secondary (Z) The primary power connectors provide the majority of the power to the system board. These connectors are designed to accommodate the power supply installed in the system. Auxiliary Power Connector (EE) The auxiliary power connector provides for the connection of an additional power source. 22 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 23 Wednesday, September 2, 1998 9:23 AM Memory The system comes standard with 256-MB of ECC RAM. System RAM is expandable up to 4-GB using ECC 50- or 60-ns 72-bit EDO DIMMs (16 DIMM sockets) with gold contacts. Main memory resides on an expansion card, called a memory module, designed specifically for this server. The memory module contains slots for 16 DIMMs, each of which must be at least 32 MB, and is attached to the system board through a dedicated connector. Memory amounts from 128 MB to 4 GB of RAM are supported, with a 64/72-bit four-way-interleaved pathway to main memory. The 16 slots are divided into four banks of four slots each, labeled A through D. These banks support 4:1 interleaving. The memory controller supports EDO DRAMs. The ECC used for the memory module is capable of correcting single-bit errors (SBEs) and detecting 100 percent of doublebit errors over one code word. Nibble error detection is also provided. E J16 J15 J12 J11 J8 J7 J4 J3 D C B A J14 J13 J10 J9 J6 J5 J2 J1 Figure 4: Memory Banks Memory 23 3424.boo Page 24 Wednesday, September 2, 1998 9:23 AM Note: Each memory bank includes two DIMM sockets in each row of connectors. When installing DIMMs, be careful to install the DIMMs in the correct sockets for the bank. DIMM Installation Sequence You must install DIMMs in the correct order and in entire banks. All DIMMs in the bank must be the same size and speed. DIMMs in other banks may differ in size. If you use slower DIMMs in another bank, all DIMMs operate at the slower speed (see Figure 4 on page 23). The sequence in which you must fill the banks is: 1. Memory bank A 2. Memory bank B 3. Memory bank C 4. Memory bank D System Memory Addressing System memory begins at address 0 and is continuous (flat addressing) up to the maximum amount of DRAM installed (exception: system memory is noncontiguous in the ranges defined as memory holes using configuration registers). The system supports both base (conventional) and extended memory. • Base memory is located at addresses 00000h to 9FFFFh (the first 1 MB). • Extended memory begins at address 0100000h (1 MB) and extends to FFFFFFFFh (4 GB), which is the limit of supported addressable memory. The top of physical memory is a maximum of 4 GB (to FFFFFFFFh) Memory holes can be configured in Setup or the SSU and are used by some legacy ISA boards. If you do not need to set up a memory hole for an ISA expansion board, leave the memory in a contiguous state for optimal performance. 24 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 25 Wednesday, September 2, 1998 9:23 AM Memory Configuration BIOS automatically detects, sizes, and initializes the memory array, depending on the type, size, and speed of the installed DIMMs, and reports memory size and allocation to the system via configuration registers. In a 4 GB configuration, a small part of memory (typically 32 MB) is not remapped above 4 GB. If your OS does not support more than 4 GB of physical memory, this small part of the memory is effectively lost. Table 3: Sample DIMM Component Combinations Bank A (slots J1 - 4) Bank B (slots J5 - 8) Bank C (slots J9 - 12) Bank D (slots J13 - 16) 4x64 Total Memory Note: Use DIMMs that have been tested for compatibility with the system board. Contact your sales representative or dealer for a list of approved DIMMs. Table 3 lists some sample size combinations. 256 MB 4x64 4x32 4x64 4x32 384 MB 4x64 4x64 4x64 4x64 4x32 4x32 768 MB 4x64 4x64 4x64 4x64 1024 MB 4x128 4x64 4x32 4x32 1024 MB 4x128 4x128 4x64 4x64 1536 MB 4x128 4x128 4x128 4x128 2048 MB 4x256 4x128 4x64 4x64 2048 MB 4x256 4x256 4x128 4x128 3072 MB 4x256 4x256 4x256 4x256 4096 MB 4x32 512 MB 512 MB Memory 25 3424.boo Page 26 Wednesday, September 2, 1998 9:23 AM System Security To help prevent unauthorized entry or use of the system, the system includes a three-position key lock/switch to permit selected access to drive bays (position is communicated to the BMC, see “System Management Connectors” on page 16). The system also includes server management software that monitors the chassis intrusion switch. Mechanical Locks and Monitoring The system includes a chassis intrusion switch. When the access cover is opened, the switch transmits an alarm signal to the system board, where server management software processes the signal. You can program a response to an intrusion, for example, the system may power down or lock the keyboard. Software Locks via the SSU or BIOS Setup The system setup utility (SSU) provides a number of security features to prevent unauthorized or accidental access to the system. Once the security measures are enabled, access to the system is allowed only after you enter the correct password(s). For example, the SSU allows you to: 26 • Enable the keyboard lockout timer so the server requires a password to reactivate the keyboard and mouse after a specified time-out period of 1 to 120 minutes • • Set and enable administrator and user passwords • • Activate a hot-key combination to enter secure mode quickly Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel reset and power switches Disable writing to the diskette drive when secure mode is set Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 27 Wednesday, September 2, 1998 9:23 AM Using Passwords If you set and enable a user password but not an administrator password, enter the user password to boot the system and run the SSU. If you set and enable both a user and an administrator password: • Enter either one to boot the server and enable the keyboard and mouse • Enter the administrator password to access the SSU or BIOS Setup to change the system configuration Secure Mode Configure and enable the secure boot mode by using the SSU. When secure mode is in effect, you: • Can boot the system and run the OS, but you must enter the user password to use the keyboard or mouse • Cannot turn off system power or reset the system from the front panel switches Secure mode has no effect on functions enabled via the Server Manager Module or power control via the real-time clock (RTC). Taking the system out of secure mode does not change the state of system power. That is, if you press and release the power switch while secure mode is in effect, the system will not power off when secure mode is later removed. However, if the front panel power switch remains depressed when secure mode is removed, the system will power off. System Security 27 3424.boo Page 28 Wednesday, September 2, 1998 9:23 AM Summary of Software Security Features Table 4 lists the software security features and describes what protection each offers. In general, to enable or set the features listed here, you must run the SSU and go to the Security Menu (described in “Security Add-in” on page 116). The table also refers to other SSU menus and to the Setup utility. For more information on setting the security features, see “Security Menu” on page 92, and “Security Add-in” on page 116. Table 4: Software Security Features 28 Feature Description Secure boot mode To enter secure mode: Set and enable a password to automatically put the system into secure mode. If you set a hot-key combination, you can secure the system by pressing the key combination. This means you do not have to wait for the inactivity time-out period. See “Security Menu” on page 92. When the system is in secure mode: The system boots and runs the OS, but does not accept mouse or keyboard input until you enter the user password. At bootup, if the system detects a CD in the CD-ROM drive or a diskette in drive A, it requests a password. When you enter the password, the system boots from CD or diskette and disables secure mode. If you have not installed a CD-ROM drive or if there is no CD in the drive or diskette in drive A, the system boots from drive C and automatically enters secure mode. All enabled secure mode features go into effect at bootup. To leave secure mode: Enter the correct password(s). Disable writing to diskette In secure mode, the system will not boot from or write to a diskette unless a password is entered. To set these features, see “Security Menu” on page 92 and “Security Options” on page 117. Disable the power and reset buttons If you enable this protection feature in the SSU, the system disables the power and reset buttons when in secure mode. See “Security Options” on page 117. Set a time-out period so that keyboard and mouse input are not accepted. Also, blank screen and inhibit writes to diskette You can specify and enable an inactivity time-out period of from 1 to 120 minutes. If no keyboard or mouse action occurs for the specified period, keyboard and mouse input is not accepted. To set this feature, see “Security Menu” on page 92. If video blanking is enabled, the monitor display goes blank until you enter the correct password(s). To set this feature, see “Security Menu” on page 92. Control access to the SSU: set administrator password To control access to the system configuration, set an administrator password and enable it through Setup or the SSU. If both the administrator and user passwords are enabled, either can be used to boot the system or enable the keyboard and/or mouse, but only the administrator password allows changes to Setup and the SSU. Once set, passwords can be disabled by setting the password to a null string or by changing the Clear Password jumper. See “Security Add-in” on page 116 to set the password to a null string; or, to change the jumper, see “Password Clear Jumper” on page 75. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 29 Wednesday, September 2, 1998 9:23 AM Table 4: Software Security Features (Continued) Feature Description Control access to the system other than SSU: set user password To control access to the system, set a user password and enable the Password on Boot field through Setup or the SSU. Once set, passwords can be disabled by setting the password to a null string or by changing the Clear Password jumper. See “Security Add-in” on page 116 to set the password to a null string; or, to change the jumper, see “Password Clear Jumper” on page 75. Boot without keyboard The system can boot with or without a keyboard. During POST and before the system boots, BIOS automatically detects and tests the keyboard, if present, and displays a message. No entry exists in the SSU for enabling or disabling a keyboard. Do not plug in a keyboard while power is applied to the system. Specify the boot sequence The sequence you specify in the BIOS (see “Boot Device Priority Submenu” on page 96) or the SSU (see “Multiboot Options Add-in” on page 115) determines the boot order. If secure mode is enabled (user password is set), you are prompted for a password before the system boots fully. If secure mode is enabled and the Secure Mode Boot option is also enabled, the system boots fully but requires a password before accepting any keyboard or mouse input. System Security 29 3424.boo Page 30 Wednesday, September 2, 1998 9:23 AM 30 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 31 Wednesday, September 2, 1998 9:23 AM Chapter 3: Installing Components Contents Introduction............................................................ 32 Replacing the Processor ........................................ 32 Installing Another Processor................................. 36 Installing Hardware ............................................... 40 Memory........................................................... 40 Drives.............................................................. 45 Installing Fans for High-Power Drives.......... 57 Expansion Cards............................................. 62 Power Supplies ............................................... 65 Replacing the Battery..................................... 68 3424.boo Page 32 Wednesday, September 2, 1998 9:23 AM Caution! ESD can damage disk drives, expansion cards, and other components. The server can withstand normal levels of environmental ESD while you hot-swap SCSI hard drives. However, we recommend doing all procedures at an ESDprotected workstation. If one is not available, you can provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground of the server when handling components. Note: If the server has less than four processors and you are adding one, then you must remove the termination board assembly from the next Slot 2 connector before you install the new processor. If you plan to reduce the number of processors in your system, then you must replace a processor with a termination board assembly. Introduction This chapter provides step-by-step instruction for installing, removing, or replacing several system components. Only authorized service personnel should perform these procedures. Follow all standard safety and ESD precautions when servicing the server. See “Static Electricity Precautions” on page 2 for more information on ESD precautions. “Opening the System” on page 3 provides detailed instructions for opening the system. All procedures in this chapter assume that any necessary access covers have been removed and that the subchassis and electronics bays have been removed, if necessary. Replacing the Processor The system is compatible with Intel Pentium® II Xeon™ processors. You can either upgrade the existing Pentium II Xeon processor or install up to three more processors of the same speed and cache size as the first processor. When replacing a processor, order a Pentium II Xeon processor upgrade kit. The kit includes the Pentium II Xeon processor, a heat sink, and latches. It is critical that a heat sink be installed on each processor. The Pentium II Xeon processor overheats and fails if it is not cooled sufficiently. The heat sink provided with the processor in the system provides all necessary cooling for the processor. For the latest details on the availability of the upgrade kits, contact one of the sources listed in the Assistance Resources document. To Replace the Processor 1. Turn off the system and disconnect all the power cords. 2. Open the case, observing the static electricity precautions in “Static Electricity Precautions” on page 2 and remove the foam cover on the electronics bay. 32 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 33 Wednesday, September 2, 1998 9:23 AM 3. Wear an anti-static wristband grounded to the system chassis and place processors on a grounded, static-free surface or conductive foam pad. 4. With your right thumb on the face of the retention module bracket (A in Figure 5), wrap your right index finger around the tab (B in Figure 5) protruding from the right edge of the bracket. A B Latch Figure 5: Releasing the Retention Module Bracket 5. Use your index finger to slightly pull the tab outward and to the left. You should not try to pull the entire bracket; rather, the back of the tab has a latch (C in Figure 5) that releases when the tab is pulled slightly. 6. When you have released the right edge of the bracket, rotate it 90° to the left until it is perpendicular to the front of the retention module. The left edge of the bracket has an open hinge that can release from the module when you rotate the bracket to the left. 7. Disengage the open hinge by moving (not rotating) the entire bracket to the right. Remove the bracket and set it aside. Replacing the Processor 33 3424.boo Page 34 Wednesday, September 2, 1998 9:23 AM 8. Pull the two tabs attached to the single edge contact (SEC) cartridge (visible after you remove the bracket—C in Figure 6) straight away from the system board. As you do, the cartridge disengages from the connector on the system board. Tab on SEC cartridge Retention module guide rails SEC cartridge Retention module guide rails Tab on SEC cartridge Processor heat sink Figure 6: Removing a Processor 9. Slide the SEC cartridge straight away from the system board, out of the retention module. Put it on a piece of conductive foam and store it in an antistatic package. 10. Remove the replacement processor cartridge from its protective wrapping. 11. Orient the SEC cartridge so that the heat sink faces away from the center of the system board. If you are installing a termination card assembly, orient it so that the side with the label faces toward the center of the system board. 34 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 35 Wednesday, September 2, 1998 9:23 AM 12. With the tabs at the top of the SEC cartridge completely open (pulled outward, away from the center of the cartridge—C in Figure 7), slide the cartridge into the guide rails of the retention module (B in Figure 7). When done properly, the triangular ends of the tabs (with two round pegs on each) fit into the entrance to the guide rails. SEC cartridge Retention module guide rails Tab on SEC cartridge Processor heat sink (must face away from the center of the system board Figure 7: Installing a Processor 13. When the cartridge meets resistance, push the two tabs toward each other (E in Figure 7) until the processor is fully seated. 14. Reattach the retention module bracket: a. With the bracket in an open position (perpendicular to the front of the retention module), slide the open hinge at the left of the bracket into its receptacle at the left of the retention module. b. Rotate the bracket to the right until it reaches the retention module. With your right thumb on the face of the bracket and your right index finger around the tab at the right of the bracket, slightly pull the tab outward and to the left to open the latch at the back of the tab. c. As you open the latch on the back of the tab, slide the right edge of the bracket onto the retention module and release the tab. If done correctly, the bracket will latch securely. Replacing the Processor 35 3424.boo Page 36 Wednesday, September 2, 1998 9:23 AM 15. Reinstall the foam cover. Note: The foam cover is required to control airflow past the processors for proper cooling. Failure to install the foam cover could result in damage to the processors and other system components. Note: If the server has less than four processors and you are adding one, then you must remove the termination board assembly from the next Slot 2 connector before you install the new processor. If you plan to reduce the number of processors in your system, then you must replace a processor with a termination board assembly. 16. Close the case, as described in “Closing the System” on page 7. 17. Reconnect the power cord and turn on the system. Installing Another Processor The system is compatible with Intel Pentium® II Xeon™ processors. You can either upgrade the existing processor or install another processor of the same speed as the original processor. When adding a processor, order a Pentium II Xeon processor upgrade kit. The kit includes the Pentium II Xeon processor, a heat sink, and latches. It is critical that a heat sink be installed on each processor. The Pentium II Xeon processor overheats and fails if it is not cooled sufficiently. The heat sink provided with the processor in the system provides all necessary cooling for the processor. For the latest details on the availability of the upgrade kits, contact one of the sources listed in the Assistance Resources document. To Install a Second Processor 1. Turn off the system and disconnect the power cord. 2. Open the case, observing the static electricity precautions in “Static Electricity Precautions” on page 2 and remove the foam cover on the electronics bay. 3. Wear an anti-static wristband grounded to the system chassis and place processors on a grounded, static-free surface or conductive foam pad. 4. Remove the termination card in the lowest numbered empty processor slot. (Processor slots are numbered from the bottom up or from the edge of the system board toward the center of the board.) With your 36 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 37 Wednesday, September 2, 1998 9:23 AM right thumb on the face of the retention module bracket (A in Figure 8), wrap your right index finger around the tab (B in Figure 8) protruding from the right edge of the bracket. A B Latch Figure 8: Releasing the Retention Module Bracket 5. Use your index finger to slightly pull the tab outward and to the left. You should not try to pull the entire bracket; rather, the back of the tab has a latch that releases when the tab is pulled slightly. 6. When you have released the right edge of the bracket, rotate it 90° to the left until it is perpendicular to the front of the retention module. The left edge of the bracket has an open hinge that can release from the module when you rotate the bracket to the left. 7. Disengage the open hinge by moving (not rotating) the entire bracket to the right. Remove the bracket and set it aside. Installing Another Processor 37 3424.boo Page 38 Wednesday, September 2, 1998 9:23 AM 8. Pull the two tabs attached to the termination module (visible after you remove the bracket—C in Figure 9) straight away from the system board. As you do, the termination module disengages from the connector on the system board. Tab on retention module Retention module guide rail Termination module Retention module guide rail Tab on retention module Figure 9: Removing the Termination Module 9. Slide the termination module straight away from the system board, out of the retention module. Put it on a piece of conductive foam and store it in an antistatic package. 10. Remove the processor cartridge from its protective wrapping. 11. Orient the S.E.C. cartridge so that the heat sink faces away from the center of the system board. 12. With the tabs at the top of the S.E.C. cartridge completely open (pulled outward, away from the center of the cartridge, Figure 10), slide the cartridge into the guide rails of the retention module (Figure 10). When done properly, the triangular ends of the tabs (with two round pegs on each) fit into the entrance to the guide rails. 38 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 39 Wednesday, September 2, 1998 9:23 AM SEC cartridge Retention module guide rail Tab on SEC cartridge Processor heat sink (must face away from the system board) Figure 10: Installing a Processor 13. When the cartridge meets resistance, push the two tabs toward each other (Figure 10) until the processor is fully seated. 14. Reattach the retention module bracket: a. With the bracket in an open position (perpendicular to the front of the retention module), slide the open hinge at the left of the bracket into its receptacle at the left of the retention module. b. Rotate the bracket to the right until it reaches the retention module. With your right thumb on the face of the bracket and your right index finger around the tab at the right of the bracket, slightly pull the tab outward and to the left to open the latch at the back of the tab. c. As you open the latch on the back of the tab, slide the right edge of the bracket onto the retention module and release the tab. If done correctly, the bracket will latch securely. 15. Reinstall the foam cover. 16. Close the case, as described in “Closing the System” on page 7. 17. Reconnect the power cord and turn on the system. Note: The foam cover is required to control airflow past the processors for proper cooling. Failure to install the foam cover could result in damage to the processors and other system components. Installing Another Processor 39 3424.boo Page 40 Wednesday, September 2, 1998 9:23 AM Installing Hardware The server includes expandability features that allow you to add several types of hardware to the interior of the system. All of the procedures given in this section use the ESD precautions identified in “Static Electricity Precautions” on page 2. All of the procedures in this section refer to Chapter 2, “Installing Components”. Memory Main memory resides on an add-in board, called a memory module. The memory module contains slots for 16 DIMMs, each of which must be at least 32 MB, and is attached to the system board through a 242-pin connector. Memory amounts from 128 MB to 4 GB of DRAM are supported, with a 64/72-bit four-way-interleaved pathway to main memory. The 16 slots are divided into four banks of four slots each, labeled A through D. These banks support 4:1 interleaving. The memory controller supports EDO DIMMs only. The ECC used for the memory module is capable of correcting single-bit errors (SBEs) and detecting 100 percent of double-bit errors over one code word. Nibble error detection is also provided. Removing the Memory Module The memory module must be removed before you can change the memory configuration. See “Memory” on page 23 for memory size and requirements. To Remove the Memory Module 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Remove the access cover (see “Opening the System” on page 3). 3. Remove the foam cover over the electronics bay. 40 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 41 Wednesday, September 2, 1998 9:23 AM 4. Remove the memory module from the system board by pulling it gently from the electronics bay (see Figure 11). It is not necessary to open the electronics bay to remove the memory module. Figure 11: Removing the Memory Module 5. Place the module component-side up on a nonconductive, static-free surface. Removing DIMMs When adding and removing DIMMs, remember that DIMMs must be installed or removed by banks. Each bank consists of four DIMM sockets. All DIMMs in the bank must be installed and all must be of the same size and speed. See Figure 4 on page 23 for the location of the DIMM sockets in each bank. Installing Hardware 41 3424.boo Page 42 Wednesday, September 2, 1998 9:23 AM To Remove DIMMs 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Remove the memory module and place it component-side up on a nonconductive, static-free surface (see “Removing the Memory Module” on page 40). Caution! Use extreme care when removing a DIMM. Too much pressure can damage the socket. Apply only enough pressure on the plastic ejector levers to release the DIMM. 3. Gently push the plastic ejector levers out and down to eject a DIMM from its socket. 4. Hold the DIMM only by its edges, being careful not to touch its components or gold edge connectors. Carefully lift it away from the socket and store it in an antistatic package. 5. Repeat steps 3 and 4 to remove other DIMMs as necessary. If you are replacing DIMMs, proceed to “Installing DIMMs” on page 43. If you are removing DIMMs, continue this procedure. 6. Reinstall the memory module (see “Installing the Memory Module” on page 44). 7. Reinstall the foam cover. 8. Reinstall the access cover using the original screws. 9. Connect all external cables and power cords to the system. 10. Turn on the monitor and then the system. 11. Run the SSU/BIOS Setup (see “Advanced Chipset Control Submenu” on page 91 and “Resource Configuration Add-in Window” on page 112) to configure the system and to properly set up advanced memory attributes as required. 42 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 43 Wednesday, September 2, 1998 9:23 AM Installing DIMMs When adding and removing DIMMs, remember that DIMMs must be installed or removed by banks. Each bank consists of four DIMM sockets. All DIMMs in the bank must be installed and all must be of the same size and speed. See Figure 4 on page 23 for the location of the DIMM sockets in each bank. To Install DIMMs 1. Holding the DIMM only by its edges, remove it from its antistatic package. 2. Orient the DIMM so that the two notches in the bottom edge of the DIMM align with the keyed socket on the memory module. 3. Insert the bottom edge of the DIMM into the socket, then press down firmly on the DIMM until it seats correctly (see Figure 12). Caution! Use extreme care when installing a DIMM. Applying too much pressure can damage the socket. DIMMs are keyed and can be inserted in only one way. Mixing dissimilar metals might cause memory failures later, resulting in data corruption. Install DIMMs with gold-plated edge connectors only in gold-plated sockets. Figure 12: Installing a DIMM Installing Hardware 43 3424.boo Page 44 Wednesday, September 2, 1998 9:23 AM 4. Push the ejector levers on the socket ends to the upright position. Note: DIMM slots on the memory module must be installed only in certain configurations. See “Memory Configuration” on page 25 for requirements. 5. Repeat steps two through four to install each DIMM. 6. Reinstall the memory module (see “Installing the Memory Module” on page 44). 7. Reinstall the foam cover(s). 8. Reinstall the access cover using the original screws. 9. Connect all external cables and the power cords to the system. 10. Turn on the monitor and then the system. 11. Run the SSU (see “Resource Configuration Add-in Window” on page 112) to configure the system and to properly attribute ECC memory. Installing the Memory Module Caution! The memory module is held in place by the 242-pin connector on the system board, the guide rail at the back of the electronics bay, and a plastic guide at the front of the electronics bay. You must support the module until it is fully seated in the connector. Once you have installed any DIMMs that you want, you must re-install the memory module. To Install the Memory Module 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Holding the memory module by its edges, align the module so its edge engages in the guide rail at the back of the electronics bay. 3. Push the memory module toward the system board until it fully engages its connector. 4. Install the foam pad in the electronics bay. 5. Replace the system access cover and screws. 44 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 45 Wednesday, September 2, 1998 9:23 AM Drives The case must be opened to add or replace drives (such as disk drives and CD-ROM drives) in the system. Refer to “Opening the System” on page 3, for instructions on opening and closing the case. While SCA-2 SCSI drives can be added or removed without opening the case, installing and removing these drives is discussed under “SCSI Hard Disk Drives” on page 54. The Diskette Drive The diskette drive is included in the original configuration. If you need to replace the diskette drive, follow the instructions below. Removing the Diskette Drive You should only replace the diskette drive if the originally installed drive fails. To Remove the Diskette Drive 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Remove the access cover (see “Opening the System” on page 3). 3. Remove the foam and fans from the subchassis. Be sure to label the fans and fan cables as you remove them. 4. Disconnect the power and signal cables (Figure 13) from the diskette drive. The connectors are keyed for ease in reconnecting them to the drive. Installing Hardware 45 3424.boo Page 46 Wednesday, September 2, 1998 9:23 AM Figure 13: Removing the Diskette Drive 5. Remove and save the screw that secures the diskette drive carrier to the side of the 5.25-inch drive bay. 6. Slide the carrier toward the back of the chassis to disengage the tabs from the slots in the side of the 5.25-inch drive bay. 7. Remove the carrier/drive from the chassis and place it component-side up on an antistatic surface. 46 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 47 Wednesday, September 2, 1998 9:23 AM 8. Remove the three screws that hold the carrier to the drive, and set them and the carrier aside. See Figure 14. Figure 14: Removing the Diskette Drive Carrier 9. Place the drive in an antistatic protective wrapper if you are not reinstalling the same drive. 10. Reinstall the foam pads, fans (see “Installing an Individual System Fan” on page 62) and the access cover using the original screws. Installing the Diskette Drive You should only replace the diskette drive if the originally installed drive fails. To Install the Diskette Drive 1. Remove the new 3.5-inch diskette drive from its protective wrapper, and place it component-side up on an antistatic surface. 2. Set any jumpers or switches according to the drive manufacturer's instructions. 3. Place the drive carrier on the component-side of the drive, and align the three mounting holes. Installing Hardware 47 3424.boo Page 48 Wednesday, September 2, 1998 9:23 AM 4. Attach the carrier to the drive with three screws of the appropriate size and length (reuse the screws you removed before). Tighten the screws firmly. Note: The 3.5-inch diskette drive is not installed in the 5.25-inch drive bay. The diskette drive carrier attaches to the outside of the 5.25-inch drive bay (see Figure 13 on page 46). 5. Position the carrier so that the two protruding notches fit into the corresponding slits in the side of the 5.25-inch drive bay. Slide the assembly toward the front of the system to engage the notches. 6. Make sure the front of the drive fits correctly in the front opening of the system. When properly positioned, the carrier notches extend slightly into the interior of the 5.25-inch drive bay and the threaded hole in the carrier aligns with the threaded hole in the frame. 7. Secure the assembly to the 5.25-inch bay with the screw you removed earlier; tighten the screw firmly. 8. Connect the signal and power cables to the drive. The red stripe on the signal cable must face toward the center of the drive. 9. Reinstall the foam pads, fans (see “Installing an Individual System Fan” on page 62) and the access cover using the original screws. 10. Run the SSU or BIOS Setup to specify that the diskette drive is installed in the system (“Modifying Resources” on page 114 or “Main Menu” on page 85). Drive Cabling Considerations Excluding the diskette drive, there are two types of devices that can be installed in the server; IDE devices and SCSI devices. This section covers cabling consideration for both types of devices. These cable considerations apply to any devices using the IDE or narrow SCSI controllers. The number of devices you can install depends on: • • • 48 The number supported by the bus The number of physical drive bays available The combination of SCSI and IDE devices Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 49 Wednesday, September 2, 1998 9:23 AM IDE Requirements An 18-inch long IDE cable that supports two drives is standard in the system. If you install an IDE hard drive, we recommend placing it in the lowest internal drive bay to make cabling easier, particularly if you also have an IDE device in the 5.25-inch drive bay. For proper IDE operation, note the cable length specified in Figure 15. If no drives are present on an IDE channel, the cable must be removed. If only one drive is installed, it must be connected at the end of the cable. 12" 6" System board Drive 1 Drive 0 18" Note: If you disable the IDE controller to reuse the interrupt for that controller, you must physically unplug the IDE cable from the system board. Simply disabling the drive by configuring the SSU option does not free the interrupt. Figure 15: IDE Cable Dimensions SCSI Requirements One wide SCSI cable is standard in the system, connecting the system board to the SCSI backplane. Terminate only the peripheral at the end of the SCSI cable. Hard drives usually provide active termination, while SCSI CD-ROM drives do not. Because we recommend putting hard drives only in the internal bays, you should route the SCSI cable so that the last device on it is a hard drive in the internal bay. The SCSI backplane in thew internal SCSI drive bay provides active termination for the SCSI drives connected to the backplane. In general, install legacy devices in the 5.25-inch drive bay and connect them to the narrow SCSI cable. Ultra and Ultra-2 devices are normally hard drives connect them to the SCSI backplane at the rear of the SCSI drive bay. The wide SCSI connectors support either single-ended (SE) or low voltage differential (LVD) drives. Installing a 5.25-inch Peripheral in the Front Bay Three 5.25-inch half-height bays provide space for tape backup, CD-ROM, or other removable media drives. Note: It is important that the cabling and connections meet the SCSI bus specification. Otherwise, the bus may be unreliable and data corruption may occur or devices might not work at all. You must terminate the SCSI bus at the end of the cable; the last device on the cable usually provides bus termination. Caution! We recommend that you do not install hard drives in the 5.25-inch bays: the drives cannot be properly cooled in this location; also, a hard drive generates EMI and is therefore more susceptible to ESD in this location. Installing Hardware 49 3424.boo Page 50 Wednesday, September 2, 1998 9:23 AM Either type of device (IDE or SCSI) can be installed in the 5.25-inch peripheral bays. The system board only provides a single IDE cable and therefore only supports two IDE devices. The single narrow SCSI connector on the system board supports up to seven devices. The last device on the SCSI bus must be terminated. To Install a 5.25-inch Device 1. Observe the safety and ESD precautions in“Static Electricity Precautions” on page 2. Also see the cabling considerations in “Drive Cabling Considerations” on page 48. 2. Open the front door by rotating its right side out and to the left. 3. Remove the access cover, see “Opening the System” on page 3. 4. Push the tab (A in Figure 16) on the left side of the EMI metal shield Note: System EMI integrity and cooling are both protected by having drives installed in the bays or filler panels and EMI shields covering the bays. When you install a drive, save the panel and shield to reinstall in case you should later remove the drive and not reinstall one in the same bay. to the right to disengage it from the chassis. Removeand save the shield. Tab on EMI metal shield Figure 16: Removing the EMI Shield 50 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 51 Wednesday, September 2, 1998 9:23 AM 5. Open the subchassis (see “Opening the Subchassis and Electronics Bay” on page 5) to gain access to the back of the 5.25-inch drive bay. 6. Remove the drive from its protective wrapper, and place it on an antistatic surface. 7. Set any jumpers or switches on the drive according to the drive manufacturer’s instructions. 8. Using two screws of the appropriate size and length (not supplied), attach each plastic slide rail (see Figure 17) with its metal grounding plate to the drive. Slide rail Tab on slide rail Removable media device Figure 17: Attaching the Slide Rails 9. Position the drive so the plastic slide rails engage in the bay guide rails. Push the drive into the bay until the slide rails lock in place. 10. Connect a power cable to the drive. The connectors are keyed and can be inserted in only one way. Installing Hardware 51 3424.boo Page 52 Wednesday, September 2, 1998 9:23 AM 11. Connect a signal cable to the drive. Caution! The internal narrow SCSI interface in this system supports only single-ended SCSI devices. Connecting differential SCSI drive types to this interface can result in electrical damage to the system board and peripherals. • SCSI drive: Attach connectors on the cable to the SCSI device or devices you are installing. • IDE drive: The system board has one IDE connector. It can support an IDE signal cable up to 18 inches long. See Figure 15 on page 49 for the cable dimensions. 12. If the drive requires any other cables, connect them. 13. Close the subchassis and make sure the foam cover is properly installed, being careful not to pinch any wires or cables (see “Closing the Subchassis and Electronics Bay” on page 7). 14. Replace the access cover, see “Closing the System” on page 7. 15. Close the front door. Removing a 5.25-inch Peripheral from the Front Bay If you remove a device from the 5.25-inch drive bay and do not replace it with another 5.25-inch device of the same height, replace the EMI shield(s) in the drive bay to maintain the EMI and airflow characteristics of the chassis. To Remove a 5.25-inch Device 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Open the front door by rotating its right side out and to the left. 3. Remove the access panel, see “Opening the System” on page 3. 4. Open the subchassis (see “Opening the Subchassis and Electronics Bay” on page 5) to gain access to the back of the 5.25-inch drive bay. 5. Disconnect the power and signal cables from the drive. 52 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 53 Wednesday, September 2, 1998 9:23 AM 6. The drive has two protruding plastic, snap-in rails attached. Squeeze the rail tabs toward each other as you carefully slide the drive forward out of the bay, and place it on an antistatic surface (Figure 18). Tab on slide rail Removable media device Slide rail Figure 18: Removing a Removable Media Device 7. Remove and save the four screws and two slide rails. 8. If you do not replace the device with another 5.25-inch device, replace the EMI shields to maintain the EMI and airflow characteristics of the chassis. If the device is a SCSI device and it was installed at the end of the SCSI signal cable, modify the cable and termination arrangement so that a proper termination exists at the end of the cable (it can be a termination device only, not necessarily a SCSI peripheral). 9. Close the subchassis and make sure the foam cover is properly installed, being careful not to pinch any wires or cables (see “Closing the Subchassis and Electronics Bay” on page 7). Installing Hardware 53 3424.boo Page 54 Wednesday, September 2, 1998 9:23 AM 10. Replace the access panel, see “Closing the System” on page 7. 11. Close the front door. Caution! Electrostatic discharge (ESD) can damage disk drives and other components. The server can withstand normal levels of ESD while you hot-swap hard disk drives. Performing all procedures in this manual at an ESD-protected workstation. If one is not available, wear an antistatic wrist strap attached to chassis ground when handling components. SCSI Hard Disk Drives The system supports a variety of SCSI devices. As shipped from the supplier, the system might contain no hard disk drives. Contact your sales representative or dealer for a list of approved SCSI devices. If you install 10,000 rpm SCSI hard drives, you must install heat sinks on the drives and additional fans in the chassis. See the sections below for specific instructions. Installing Heatsinks on High-Power Drives If you plan to use SCSI drives whose power exceeds 15 watts, you must install heatsinks on those drives. To Install Heatsinks on Hard Drives 1. Position each heatsink (Figure 19) so that the three screw holes in the Caution! heatsink align with the corresponding holes in the hard drive. The holes are placed so that you can position the heatsink in only one way: with the fins extending along the side and the top of the hard drive. If you install high-power drives, you must also install additional system fans. See “Installing Fans for HighPower Drives” on page 57. Hard drive, label side Heat sink Hard drive, component side Figure 19: Installing Heatsinks on a Hard Drive 54 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 55 Wednesday, September 2, 1998 9:23 AM 2. Use three screws (D) to attach each heatsink to the drive. 3. To insert the drive into the hot-docking bay, you must attach a carrier to the drive. See “Mounting a SCSI Hard Disk Drive in a Carrier” on page 55. Mounting a SCSI Hard Disk Drive in a Carrier Before you can install an LVD SCA-2 SCSI hard drive in the system, you must mount it on a drive carrier to allow easy installation into the server. To Mount a SCSI Drive on a Carrier 1. Remove the 3.5-inch hard drive from its wrapper and place it on an antistatic surface. 2. Orient the drive so the connector is near the top surface of the drive, then place the carrier on top of the drive. 3. Using four screws of the correct size and length (not supplied), attach the carrier to the drive (see Figure 20). Note: Faster drives, those operating at or above 10,000 RPM, require the use of aluminum drive carriers to improve heat dissipation. Do not mount these drives on plastic carriers. Figure 20: Hard Disk Drive and Carrier Installing Hardware 55 3424.boo Page 56 Wednesday, September 2, 1998 9:23 AM Hot-swapping a SCSI Drive A bank of six yellow LEDs on the front panel monitors the drive status of each drive in the hot-docking bay. Each LED corresponds directly to a drive, so that the upper-most LED reflects an error condition in the uppermost drive. The six LEDs and corresponding drives are numbered (top to bottom) zero through five. When a yellow LED is on continuously, it is okay to hot-swap (replace) a bad drive with a good one. You do not need to shut the system down to hot-swap a drive. To Hot-swap a SCSI Drive 1. Open the front system door by rotating its right side out and to the left. 2. If you installed a padlock on the metal door to the SCSI drive bay, unlock the padlock and remove it. 3. Press the plastic latch securing the metal door to the SCSI drive cage, and open the door. 4. Check the bank of yellow LEDs on the front panel to determine which drive is bad. 5. Press the rounded tab on the right of the carrier to the left (toward the center of the drive, Figure 21) while gently pulling straight down on the carrier handle (Figure 21). This disengages the latch that secures the carrier to the chassis. Carrier handle Tab Figure 21: Disengaging Drive Carrier from Chassis 56 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 57 Wednesday, September 2, 1998 9:23 AM 6. Grasp the plastic carrier handle and pull it toward you to disengage the drive connector from the backplane connector. 7. Carefully slide the bad drive forward out of the bay. Place the drive on an antistatic surface. 8. Position the new plastic carrier and drive assembly so that it engages the bay guide rails. 9. Push the drive into the bay. To engage the latch, the carrier handle should be approximately at a 45° angle from the vertical front of the chassis. As you push the drive into the bay, the two rounded notches in the carrier handle (Figure 22) slide onto the two round pegs inside the drive bay . When they engage, push the handle straight up to lock the notches onto the pegs and press the rounded tab on the right of the carrier to the left until it clears the edge of the bay and snaps into place. Peg inside drive bay Carrier handle Notch on carrier handle Figure 22: Installing a New Drive 10. Close the metal door, and secure it to the chassis with the plastic latch. 11. For security and to prevent unauthorized access to the bays, insert a padlock through the metal loop protruding through the door. 12. Close the front system door. Installing Fans for High-Power Drives If the SCSI drives you use have a power rating in excess of 15 watts, install three additional system fans: two in the front fan bay and one in the upper power supply bay. Purchase the additional fans through normal channels. Installing Hardware 57 3424.boo Page 58 Wednesday, September 2, 1998 9:23 AM Installing a Fan in the Power Supply Bay This procedure describes installation of a fan in the third power supply module bay. This procedure is only valid for configurations using two power supply modules. To Install a Fan In the Power Supply Bay 1. Remove four screws, the grill plate, and fan from your kit. 2. Remove the plate (Figure 23) that covers the power supply bay closest to the PCI slots. It is the uppermost bay when the server is standing upright in pedestal mode. Fan Cable Plate covering power supply bay Grill plate Figure 23: Installing a Fan in the Power Supply Bay 58 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 59 Wednesday, September 2, 1998 9:23 AM 3. Using four screws, attach the fan to the grill plate (Figure 23) so that the fan label faces the plate. 4. Insert the fan/grill plate assembly into the power supply bay so that the cable points downward (Figure 23) from the fan toward the other two power supplies, and so the fan’s label faces out the back of the chassis. This alignment is important to ensure correct airflow direction. 5. Using four screws, attach the fan/grill plate assembly to the chassis (Figure 23). Removing an Individual System Fan The subchassis houses up to eight system fans. Not all of these fans are required in standard configurations. If a fan fails, follow this procedure to remove the failed fan. Note: Correct airflow direction: The side of each fan is embossed with directional arrows indicating airflow direction. Always note the direction of the arrows on a fan before removing it. You will need this information later when you install a different fan. To Remove an Individual System Fan 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Remove the access cover (see “Removing the Access Cover” on page 3). Installing Hardware 59 3424.boo Page 60 Wednesday, September 2, 1998 9:23 AM 3. Remove the foam cover from the front subchassis by pulling it straight out (see Figure 24). Be careful not to break the foam. Figure 24: Removing the System Fan Assembly 4. For better access to the individual fan cables on the front panel board, carefully rotate the right edge of the foam fan assembly outward into the opening where the foam cover was. 60 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 61 Wednesday, September 2, 1998 9:23 AM 5. Label and disconnect the desired fan cable from the front panel board. Be sure to note the position of the cable where it is held in place in the foam fan assembly (see Figure 25). 1 2 1 2 3 4 5 6 7 8 3 4 5 6 1 7 8 Note: Figure 25: Fan Cabling 6. Remove the fan cable from the foam assembly, being careful not to break the foam. 7. Remove the fan from the foam assembly. All systems fans sit differently in the assembly, but in general, each fan can slide in and out of the foam in only one way. The two installed fans nearest the 5.25-inch drive bays (fans 6 and 7 in Figure 25) are separated by a square piece of foam (the piece with a crescentshaped hole) that extends perpendicularly from the front of the fans (in Figure 25, it is the rectangle between the round faces of fans 6 and 7). You must remove this piece to access the two fans it separates (pull it straight out). Installing Hardware 61 3424.boo Page 62 Wednesday, September 2, 1998 9:23 AM Installing an Individual System Fan Note: The removable fan pulls air from in front of the chassis so that it flows across the boards and out the back. The fan must be oriented for the correct airflow direction. In general, the fan label is on the side from which air exits the fan. Confirm correct orientation by checking the embossed arrows on the side of the fan: ⇒Arrow points horizontally toward back of chassis ⇑Arrow points vertically up Note the direction of the arrows on the existing fan before you remove it. Replace a failed fan with the same type as the one removed. The subchassis houses up to eight system fans. Not all of these fans are required in standard configurations. If you use high power hard drives, you must install additional fans. Follow this procedure to install additional fans. To Install an Individual System Fan 1. See “Removing an Individual System Fan” on page 59, as necessary. 2. Observe the safety and ESD precautions at the beginning this chapter. 3. Slide the fan into its correct receptacle in the foam fan assembly. 4. Attach the cable to the foam at the correct places (if you are replacing a bad fan, you should have recorded where each cable attaches to the foam; if you are adding a fan, see Figure 25 on page 61). 5. Position the fan assembly inside the chassis so that the individual fan cables can easily reach their connectors on the front panel board. 6. Attach the cable to the front panel at the correct connector. 7. Position the fan assembly as it was inside the chassis prior to removal, so that it rests firmly against the diskette drive at the top and the 5.25inch bays at the middle and bottom. 8. Reinstall the foam cover. It is molded to match the position of the fans and fits in only one way. 9. Reinstall the access cover using the original screws. Expansion Cards Note: If you install a PCI VGA video card, you must install it in one of the primary PCI slots. 62 The system board has seven slots for the installation of expansion cards. There are six PCI slots and one shared slot that can support either a PCI card or an ISA card. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 63 Wednesday, September 2, 1998 9:23 AM Installing an Expansion Card Caution! Expansion cards can be extremely sensitive to ESD and require careful handling. After removing the card from its protective wrapper or from the system board, place it component-side up on a grounded, static-free surface or conductive foam pad. Do not slide the card over any surface. Do not overload the system board by installing expansion cards that draw excessive current. To Install an Expansion Card 1. Remove the access panel (see “Removing the Access Cover” on page 3). 2. Remove the expansion card from its protective wrapper. Be careful not to touch the components or the gold edge connectors. 3. Set any jumpers or switches according to the manufacturer’s instructions. 4. Remove the rear foam pad from the electronics bay. 5. Remove and save the expansion slot cover (Figure 26). ISA slot (use half length board only) Six PCI slots (top to bottom= PCI B3, B2, B1, B0, A3, and A2) PCI slot A1 Figure 26: Installing an Expansion Card Installing Hardware 63 3424.boo Page 64 Wednesday, September 2, 1998 9:23 AM 6. Hold the expansion card by its top edge or upper corners. Firmly press it into an expansion slot on the system board. The tapered foot of the board retaining bracket must fit into the mating slot in the expansion slot frame. a. Install an ISA board component-side up. b. Install a PCI board component-side down. 7. Replace the screw you removed when you removed the slot cover to secure the card in the slot. 8. Attach cables to the card if necessary. 9. Replace the rear foam pad. 10. Reinstall the access panel using the original screws (see “Installing the Access Cover” on page 8). 11. Running the SSU is optional after you install or remove a PCI or ISA board. Removing an Expansion Card Caution! Slot covers must be installed on all vacant expansion slots. This maintains the electromagnetic emissions (EMI) characteristics of the system and ensures proper cooling of system components. Remember that removing an ISA expansion card may require you to use the SSU to remove it from the system configuration. To Remove an Expansion Card 1. Observe the safety and ESD precautions in “Static Electricity Precautions” on page 2. 2. Remove the access cover (“Opening the System” on page 3), and the rear foam pad. 3. Disconnect any cables attached to the board you are removing. 4. Remove and save the screw that secures the board in its slot. 5. Holding the board by its top edge or upper corners, carefully pull it out. Do not scrape the board against other components. 6. Store the board in an antistatic protective wrapper. 64 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 65 Wednesday, September 2, 1998 9:23 AM 7. If you are not reinstalling a board in the same slot, install a slot cover over the vacant slot. The tapered foot of the cover must fit into the mating slot in the expansion slot frame. 8. Replace the rear foam pad and the access panel (“Closing the System” on page 7). 9. Running the SSU is optional after you install or remove a PCI or ISA board. Power Supplies Warning! The system can be configured with two or three power supply modules. These configurations use a power share board that distributes the power supplied by two supply modules to various system components. Table 5 shows the power distribution using the power share board. Configurations using three power supply modules use the same power share board as those using two supply modules. The third module acts as a hot spare and allows hot swapping of failed power supply modules. Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing must be done by technically qualified personnel. Table 5: Power Sharing Power Supply Output B System board 5V A System board 3.3V A System board 12v-1 B System board 12V-2 A Peripheral 5V B Peripheral 12V Installing Hardware 65 3424.boo Page 66 Wednesday, September 2, 1998 9:23 AM Removing a Power Supply Module If the system configuration includes three power supply modules, hotswapping is possible; allowing you to remove a power supply module without powering down the system. If your configuration uses only two modules, you must power down the system before removing or replacing the failed power supply module. Caution! You might feel initial resistance in sliding the power supply from its bay. Do not tilt or twist the supply. Resistance is caused by the supply disengaging from its 40-pin connector. Use even, steady force to remove the supply. Removing a Power Supply Module 1. Disconnect the AC power cables from the power supply modules. You must hold the power supply retention clip to the side as you remove the power cord (see Figure 27 on page 66). 2. Remove the four screws (Figure 27) holding the power supply module to the back of the chassis. 3. Using the flared, vertical edges as handles and using both hands, slide the power supply module straight back from its bay (Figure 27). Power supply module retention clip Figure 27: Removing a Power Supply Module 66 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 67 Wednesday, September 2, 1998 9:23 AM Installing a Power Supply Module The power share board allows you to use two power supply modules or to use two modules and install a third module as a hot backup. If you install the third module, you can perform hot-swapping if a module fails. Installing a Power Supply Module 1. If you have not already powered down the system or if you are not hot- swapping the power supply module, power down the server. 2. If you are replacing a failed module, remove the failed module. See “Removing a Power Supply Module” on page 66. 3. If you are installing an additional power supply module, remove the access cover. If you are replacing a failed module, install the new module in the same bay from which you removed the failed module. 4. Slide the power supply into its bay. 5. With even force on the flared, vertical edges, push toward the front of the system until the edges rest against the rear of the chassis and the power supply module engages its connector. 6. Install and tighten the four screws holding the module to the back of the chassis. 7. Connect the AC power cable. You must slide the cover on the AC connector to access the connector itself (Figure 27 on page 66). Installing Hardware 67 3424.boo Page 68 Wednesday, September 2, 1998 9:23 AM Caution! There is a danger of explosion if the battery is incorrectly replaced. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Replacing the Battery The battery provides power for the system real-time clock and CMOS RAM, which holds the system configuration information. To Replace the Battery 1. Restart the computer and start the BIOS Setup program by pressing F2 when you are prompted to do so. 2. Write down the CMOS values from BIOS Setup so you can reenter them after you replace the battery. For more information about the setup program, see “BIOS Setup” on page 79. 3. Turn off the system and disconnect the power cords. 4. Open the case, observing the static electricity precautions in “Static Electricity Precautions” on page 2. 5. Locate the battery on the system board, see Figure 3 on page 11. The battery is circular and has the positive pole mark (+) on the top. 6. Gently pull the battery from its socket. You may need to use a screwdriver with an insulated handle or other implement to remove the battery, see Figure 28. Figure 28: Replacing the Battery 68 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 69 Wednesday, September 2, 1998 9:23 AM 7. Press the new battery in the socket with the positive pole (+) up. Be sure you have pressed the battery down far enough for it to contact the base of the socket. 8. Close the case, as described in “Closing the System” on page 7. 9. Reconnect the power cord and turn on the system. 10. Enter the BIOS Setup program and verify that the system configuration is correct using the data you recorded in Step 2. If the CMOS data is not correct, change the information in the setup screens as necessary. Troubleshooting the Battery Installation If you have problems after installing the new battery, try each of the items listed below, replacing the cover and restarting the computer after each try. • Turn off the system and ensure that all exterior cables are attached to the correct connectors and secured. • Check to be sure that all power switches are on. If the system is plugged into a power strip or surge protector, be sure it is turned on also. • Enter the BIOS Setup program and compare the settings on the screen with your notes or the system hardware manuals. Correct any discrepancies. • Turn off the system, remove the cover, and verify that all cables inside the case are attached securely. Also, make sure that the colored cable edges are aligned correctly and that the connectors did not miss any pins. Disconnect and reconnect the cables, and then replace the cover carefully so as not to disturb any cables. • Turn off the system, remove the cover and, if you have the proper test equipment, verify that the new battery has power. (It is possible, although highly unlikely, that your new battery is defective.) If these procedures fail to correct the problem, contact technical support. Installing Hardware 69 3424.boo Page 70 Wednesday, September 2, 1998 9:23 AM 70 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 71 Wednesday, September 2, 1998 9:23 AM Chapter 4: Jumpers and Drivers Contents Setting the Jumpers................................................ 72 Changing a Jumper Setting ............................ 73 CMOS Clear Jumper...................................... 74 Password Clear Jumper.................................. 75 Recovery Boot Jumper................................... 75 Installing Software and Drivers ............................ 77 Installing Video Drivers................................. 77 3424.boo Page 72 Wednesday, September 2, 1998 9:23 AM Setting the Jumpers The system board jumpers let you change several system functions. Jumpers are set to the default positions at the factory. You may need to change the jumper settings to perform the following functions: • • • Clear CMOS memory Clear the passwords from CMOS memory Recover from a failed BIOS update One 11-pin connector provides three 3-pin jumper blocks that control the functions identified above. Figure 29 shows the location and orientation of the jumpers. Items in bold in Table 6 on page 73 show the default placement for each configurable option. J6J1 11 9 7 5 3 1 Figure 29: System Board Jumpers 72 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 73 Wednesday, September 2, 1998 9:23 AM Table 6: System Board Jumper Summary Function Pins What it Does at System Reset CMOS clear 1-2, Normal Preserves the contents of the NVRAM 2-3, Forced erase Replaces the contents of the NVRAM with the manufacturing default settings Password clear Recovery boot 5-6, Protect Maintains the current passwords 6-7, Erase Clears the passwords 9-10, Normal System boots using the BIOS stored in flash memory 10-11, Recovery BIOS attempts a recovery boot, loading the BIOS code from a diskette into the flash device. Use this jumper when the BIOS code has been corrupted by a failed flash update. Changing a Jumper Setting The short general procedure for changing a configuration setting is the same for most of the jumper functions, so it is described here. To Change a Jumper Setting 1. Observe the safety and ESD precautions at the beginning of “Static Electricity Precautions” on page 2. 2. Turn off all connected peripherals, turn off system power, and disconnect all AC power cords. 3. Remove the access cover. 4. Remove the foam insert from the electronics bay. 5. Locate the configuration jumpers at the edge of the system board toward the front of the system (see Figure 29 on page 72). 6. Move the jumper to the pins specified for the desired setting. Note: You do not need to remove the system board from the chassis, and you probably do not need to remove any expansion cards. 7. Reinstall the foam insert and the access cover using the original screws, connect the power cords, and turn on the system for the change to take effect. 8. You may need to repeat these steps to move the jumper back to its original setting, depending on the jumper function. Setting the Jumpers 73 3424.boo Page 74 Wednesday, September 2, 1998 9:23 AM CMOS Clear Jumper The jumper at pins 1, 2, and 3 controls whether settings stored in CMOS nonvolatile memory (NVRAM) are retained during a system reset. To Restore the Manufacturing Default CMOS Settings 1. See “Changing a Jumper Setting” on page 73. 2. Move the CMOS jumper from pins 1 and 2 to pins 2 and 3 (the Clear CMOS memory position). 3. Reinstall the access cover for your safety (using the original screws), and connect the power cords to the system. 4. Turn the system on. Wait for POST to complete and for the messages NVRAM cleared by jumper Pressto enter Setup to appear. This automatically reprograms CMOS to its default settings, except for the password. 5. Enter Setup and make any changes necessary (for example, changing the boot device). 6. Press F10 to save the new Setup configuration and exit Setup. 7. Turn off the system, and disconnect all AC power cords from the system. 8. Again remove the access cover. 9. Move the jumper from pins 2 and 3 back to pins 1 and 2 (the Protect CMOS memory position). 10. Reinstall the access cover using the original screws, and connect the power cords to the system. 11. Run BIOS Setup or the SSU to verify the correct settings. See Chapter 5, BIOS Setup and Chapter 6, The Server Setup Utility for more information on setting BIOS and SSU fields. 74 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 75 Wednesday, September 2, 1998 9:23 AM Password Clear Jumper The jumper at pins 5, 6, and 7 controls whether a stored password is retained or cleared during a system reset. To Clear and Replace a Password Using the Jumper 1. See “Changing a Jumper Setting” on page 73. 2. Move the Password jumper from pins 5 and 6 to pins 6 and 7. 3. Reinstall the access cover for your safety (using the original screws), and connect the power cords to the system. 4. Turn the system on, and wait for POST to complete. This automatically clears the password. 5. Turn off the system, and disconnect all AC power cords. 6. Again remove the access cover. 7. Move the jumper from pins 6 and 7 back to pins 5 and 6. 8. Reinstall the access cover using the original screws, and connect the power cords to the system. 9. Run the SSU to specify a new password. See “Security Add-in” on page 116 for instructions on setting a password in the SSU. Recovery Boot Jumper The jumper at pins 9, 10, and 11 controls whether the system attempts to boot using the BIOS programmed in flash memory or if it attempts to flash the BIOS from a diskette in drive A. If an attempted BIOS update is interrupted, you may need to perform this procedure. To Perform a Recovery Boot 1. See “Changing a Jumper Setting” on page 73. 2. Move the recovery boot jumper from pins 9 and 10 to pins 10 and 11. Setting the Jumpers 75 3424.boo Page 76 Wednesday, September 2, 1998 9:23 AM 3. Reinstall the access cover for your safety (using the original screws), then connect the power cords to the system. 4. Turn the system on, and insert the Flash Memory Update Utility diskette in drive A. After the system boots, the speaker emits a single beep and the recovery process starts. This takes about three minutes. When the recovery process completes, the speaker emits two beeps. While in recovery mode, there is no screen display on the monitor. The keyboard is also disabled as the system automatically recovers the BIOS. The beep codes listed in Table 7 describe the recovery status. Table 7: Recovery Boot Beep Codes Beep Codes Message 2 Successful completion, no errors. 4 The system could not boot from the diskette. The diskette may not be bootable. Continuous series of low beeps The wrong BIOS recovery files are being used and/or the flash memory jumper is in the wrong position. 5. Turn the system off, disconnect all AC power cords from the system, and remove the access cover. 6. Move the jumper from pins 10 and 11 back to pins 9 and 10 to enable the normal boot mode. 7. Replace the foam pad and the access cover, remove the diskette from drive A, and connect the power cords to the system. 8. After running the special recovery mode, run the BIOS Setup or the SSU to specify a new password. See “Security Menu” on page 92 and “Security Add-in” on page 116 for information on setting passwords in BIOS Setup and the SSU. 76 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 77 Wednesday, September 2, 1998 9:23 AM Installing Software and Drivers Installing software and drivers is usually specific to the operating system you run on the system. However, some tips on installing drivers or other software in critical situations or under particular circumstances are provided below. Installing Video Drivers After configuring the system, you need to install video drivers to take full advantage of the features of the onboard CL-GD5480 super VGA video controller. Note: If you install a PCI VGA video card, you must install it in one of the primary PCI slots. • The software shipped with the server includes video drivers for use with Windows NT. • For other operating systems, see the operating system instructions for installing device drivers. Installing Software and Drivers 77 3424.boo Page 78 Wednesday, September 2, 1998 9:23 AM 78 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 79 Wednesday, September 2, 1998 9:23 AM Chapter 5: BIOS Setup Contents Introduction............................................................ 80 Using BIOS Setup ................................................. 81 Record Your Setup Settings........................... 81 If You Cannot Access Setup .......................... 82 Starting Setup.................................................. 82 Setup Menus .......................................................... 83 Setup Key Commands.................................... 84 Special Display Items..................................... 84 Main Menu ..................................................... 85 Advanced Menu ............................................. 87 Security Menu ................................................ 92 Server Menu ................................................... 93 Boot Menu ...................................................... 95 Exit Menu ....................................................... 97 Upgrading the BIOS.............................................. 98 Preparing for the Upgrade.............................. 98 Upgrading the BIOS..................................... 100 Recovering the BIOS ................................... 101 Changing the BIOS Language..................... 101 3424.boo Page 80 Wednesday, September 2, 1998 9:23 AM Introduction This chapter describes the BIOS Setup utility. The following chapters describe the power-on self test (POST) and other utilities for configuring and managing the server. These utilities are: • POST: described in Chapter 7, “Other Utilities” on page 125. POST checks basic system integrity and all major components. • Server Setup Utility (SSU): described in Chapter 6, “The Server Setup Utility” on page 103. Use for extended system configuration of onboard resources and expansion cards, viewing the system event log (SEL), setting boot device priority, or setting system security options. Run the SSU from a set DOS-bootable diskettes. See “What You Need to Do” on page 106 to make a set of SSU diskettes. Information entered via the SSU overrides information entered via Setup. • Emergency Management Port (EMP) Console: described in Chapter 7, “Other Utilities” on page 125. Use the EMP to access and monitor the server remotely. • FRUSDR Load Utility: described in Chapter 7, “Other Utilities” on page 125. Use to update the Field Replacement Unit (FRU), Sensor Data Record (SDR), and Desktop Management Interface (DMI) flash components. • BIOS Update Utility: described in Chapter 7, “Other Utilities” on page 125. Use to update the BIOS or recover from a corrupted BIOS update. • Firmware Update Utility: described in Chapter 7, “Other Utilities” on page 125. Use to update the BMC flash ROM. • Symbios SCSI Utility: described in Chapter 7, “Other Utilities” on page 125. Use to configure or view the settings of the SCSI host adapters and onboard SCSI devices in the system. If the system does not have a diskette drive, or the drive is disabled or misconfigured, use Setup to enable it. Or, you can move the CMOS jumper on the system board from the default setting (protect CMOS memory) to the clear setting; doing so allows most system configurations to boot. Then run BIOS Setup and the SSU to configure the system. 80 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 81 Wednesday, September 2, 1998 9:23 AM Using BIOS Setup This section describes the BIOS Setup options. Use Setup to change the system configuration defaults. You can run Setup with or without an operating system present. Setup stores most of the configuration values in battery-backed CMOS; the rest of the values are stored in flash memory. The values take effect when you boot the system. POST uses these values to configure the hardware; if the values and the actual hardware do not agree, POST generates an error message. You must then run Setup to specify the correct configuration. Run Setup: you can run Setup to modify any standard system board feature such as: • • • • • • • Select the diskette drive Select the parallel port Select a serial port Set the time or date (to be stored in the real-time clock (RTC)) Configure an IDE hard drive Specify the boot device sequence Enable the SCSI BIOS Run SSU, not Setup: you must run the SSU instead of Setup to do the following: • • Enter or change information about an expansion card Alter system resources (e.g., interrupts, memory addresses, I/O assignments) to your choices instead of those selected by the BIOS resource manager Record Your Setup Settings It is a good idea to maintain a current record of the Setup and SSU settings for each system. If the default values ever need to be restored (after a CMOS clear, for example), you must run Setup again. Referring to your notes will make the task easier. Using BIOS Setup 81 3424.boo Page 82 Wednesday, September 2, 1998 9:23 AM If You Cannot Access Setup If the diskette drive is misconfigured so that you cannot access it to run a utility from a diskette, you might need to clear CMOS memory. You must open the system, change a jumper setting, use Setup to check and set diskette drive options, and change the jumper back. For a step-by-step procedure, see “CMOS Clear Jumper” on page 74. Starting Setup You can enter and start Setup under several conditions: • When you turn on the system, after POST completes the memory test • When you reboot the system by pressing CTRL+ALT+DEL while at the DOS operating system prompt • When you have moved the CMOS jumper on the system board to the “Clear CMOS” position (enabled); for a step-by-step procedure, see “CMOS Clear Jumper” on page 74. In the three conditions listed above, after rebooting, the system displays this prompt: Press to enter SETUP In a fourth condition, when CMOS/NVRAM has been corrupted, the system displays other prompts but not the F2 prompt: Warning: cmos checksum invalid Warning: cmos time and date not set In this condition, the BIOS loads default values for CMOS and attempts to boot. 82 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 83 Wednesday, September 2, 1998 9:23 AM Setup Menus Setup has six major menus and several submenus. These menus are: 1. Main Menu a. Primary IDE Master and Slave b. Keyboard Features 2. Advanced Menu a. PCI Configuration • PCI Device, Embedded SCSI • PCI Devices b. I/O Device Configuration c. Advanced Chipset Control 3. Security Menu 4. Server Menu a. System Management b. Console Redirection 5. Boot Menu a. Boot Device Priority b. Hard Drive 6. Exit Menu Setup Menus 83 3424.boo Page 84 Wednesday, September 2, 1998 9:23 AM Setup Key Commands Table 8 lists the keys commands available in Setup and what they do. Table 8: Setup Key Commands Function Key Command Get general help F1 or ATL+H Move between menus ←→ Go to the previous item ¦ (colon) Go to the next Item Ø (zero) Change the value of an item + or - Select an item or display a submenu ENTER Leave a submenu or exit Setup ESC Reset to Setup defaults F9 Save and exit Setup F10 Special Display Items Some items displayed on the screen do not behave as normal fields. These items are either submenus or display-only fields. Table 9 provides more information. Table 9: Special Display Items When you see this: It means this: On screen, an option is shown but you cannot select it or move to that field. You cannot change or configure the option in that menu screen. Either the option is autoconfigured or autodetected, or you must use a different Setup screen, or you must use the SSU. On screen, the phrase Press Enter appears next to the option. Press ENTER to display a submenu that is either a separate full-screen menu or a pop-up menu with one or more choices. The rest of this section lists the features that display on screen after you press F2 to enter Setup. Not all of the option choices are described, because (1) a few are not user-selectable but are strictly informational, and (2) many of the choices are relatively self-explanatory. 84 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 85 Wednesday, September 2, 1998 9:23 AM Main Menu Table 10 lists the selections you can make on the Main Menu itself. Use the submenus for other selections. Default values are in bold. Table 10: Main Menu Field Options Description System Time HH:MM:SS Sets the system time System Date MM/DD/YYYY Sets the system date Legacy Diskette A: Disabled 360 KB 720 KB 1.44 MB 2.88 MB Selects the primary diskette type. Legacy Diskette B: Disabled 360 KB 720 KB 1.44 MB 2.88 MB Selects the secondary diskette type. Hard Disk Pre-delay Disabled 3, 6, 9, 12, 15, 21, or 30 seconds Adds a delay before the first BIOS access of a hard disk drive. Some hard disk drives hang if accessed before they initialize themselves. This delay ensures the hard disk drive has initialized after powerup and before being accessed. Primary Master N/A Enters submenu. Primary Slave N/A Enters submenu. Keyboard Features N/A Enters submenu. Language English (US) Spanish Italian French German Japanese (Kanji) Selects which language the BIOS displays. Note: Serial redirection does not work with Kanji. Setup Menus 85 3424.boo Page 86 Wednesday, September 2, 1998 9:23 AM Primary Master and Slave Submenu In Table 11, the features other than “Type” appear only for Type Auto, if a drive is detected. Table 11: Primary IDE Master and Slave Submenu 86 Field Options Description Type Auto None CD-ROM IDE Removable ATAPI Removable User Auto allows the system to attempt autodetection of the drive type. None informs the system to ignore this drive. CD-ROM allows the manual entry of fields described below. User allows the manual entry of all fields described below. Cylinders 1 to 2048 Number of Cylinders on Drive. This field is changeable only for Type User. This field is strictly informational for Type Auto. Heads 1 to 16 Number of read/write heads on drive. This field is available only for Type User. This field is strictly informational for Type Auto. Sectors 1 to 64 Number of sectors per track. This field is available only for Type User. This field is strictly informational for Type Auto. Maximum Capacity N/A Computed size of drive from cylinders, heads, and sectors entered. This field is available only for Type User. This field is strictly informational for Type Auto. Multi-Sector Transfers Disabled Determines the number of sectors per block for 2, 4, 8, or 16 sectors multisector transfers. This field is strictly informational for Type Auto. LBA Mode Control Disabled Enabled Enabling LBA causes logical block addressing to be used in place of cylinders, heads, and sectors. This field is strictly informational for Type Auto. 32 Bit I/O Disabled Enabled Enabling allows 32-bit IDE data transfers. This field is strictly informational for Type Auto. Transfer Mode Standard Fast PIO 1 Fast PIO 2 Fast PIO 3 Fast PIO 4 Selects the method for moving data to and from the drive. This field is strictly informational for Type Auto. Ultra DMA Disabled Enabled For use with Ultra DMA drives. This field is strictly information for Type Auto. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 87 Wednesday, September 2, 1998 9:23 AM Keyboard Features Submenu In Table 12, the settable features of the keyboard controller are listed along with the options. Table 12: Keyboard Features Submenu Field Options Description Num Lock Auto On Off Selects the power on state for the Num Lock key. Key Click Disabled Enabled Enables or disables key click. Keyboard autorepeat rate 30, 26.7, 21.8, 18.5, 13.3, 10, 6, or 2 per second Selects the key repeat rate. Keyboard autorepeat delay 1/4 sec 1/2 sec 3/4 sec 1 sec Selects the delay before the keys begin to repeat. Advanced Menu You can make the selections listed in Table 13 on the Advanced Menu itself. Refer to “PCI Configuration Submenu” on page 88, “I/O Device Configuration Submenu” on page 89, and “Advanced Chipset Control Submenu” on page 91 for information on the three other selections that appear on the Advanced Menu. Table 13: Advanced Menu Field Options Description Plug and Play OS No Yes Select Yes if you are booting a Plug and Playcapable operating system. Reset Configuration Data No Yes Select Yes if you want to clear the system configuration data during the next boot. The system automatically resets to No during the next boot. PCI Configuration N/A Enters submenu. I/O Device Configuration N/A Enters submenu. Use Multiprocessor Specification Selects the version of the multiprocessor specification to use. Some operating systems require version 1.1 for compatibility reasons. 1.1 1.4 Setup Menus 87 3424.boo Page 88 Wednesday, September 2, 1998 9:23 AM Table 13: Advanced Menu (Continued) Field Options Description Large Disk Access Mode LBA CHS Applies to IDE drives only; refers to the method used to access the drive. Most operating systems use logical block addressing (LBA); some use cylinder head sector (CHS). To verify the correct method, consult the operating system documentation. Pause Before Boot Enabled Disabled Enables a five-second pause before booting the operating system. Advanced Chipset Control N/A Enters submenu. PCI Configuration Submenu The PCI Configuration Menu contains selections that access other submenus. PCI Device, Embedded SCSI Submenu This submenu provides three fields that allow you to control certain characteristics of the embedded SCSI controllers. Table 14 lists the fields and options. Table 14: PCI Device, Embedded SCSI Submenu 88 Field Options Description Option ROM Scan Enabled Disabled Enables the option ROM scan of the selected device. Enable Master Disabled Enabled Enables the selected device as a PCI bus master. Latency Timer Default 0020h 0040h 0060h 0080h 00A0h 00C0h 00E0h Defines the minimum guaranteed time, in units of PCI bus clocks, that a device can be master on a PCI bus. Typically, option ROM code overwrites the value set by the BIOS. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 89 Wednesday, September 2, 1998 9:23 AM PCI Devices Submenu This submenu provides three fields that allow you to control certain characteristics of the PCI expansion slots. Table 15 lists the fields and options. Table 15: PCI Devices Submenu Field Options Description Option ROM Scan Enabled Disabled Enables the option ROM scan of all devices other than the onboard SCSI controllers. Enable Master Disabled Enabled Enables all devices, other than the onboard SCSI controllers, as PCI bus masters. Latency Timer Default 0020h 0040h 0060h 0080h 00A0h 00C0h 00E0h Defines the minimum guaranteed time, in units of PCI bus clocks, that a device can be master on a PCI bus. Typically, option ROM code overwrites the value set by the BIOS. I/O Device Configuration Submenu This submenu contains fields to control the I/O ports on the back panel of the system. Table 16 lists the fields and the options available for each. Table 16: I/O Device Configuration Submenu Field Options Description Serial Port A Disabled Enabled Auto OS Controlled Auto forces the BIOS to configure the port. OS Controlled is shown when the operating system controls the port. Base I/O Address 3F8 2F8 3E8 2E8 Selects the base I/O address for COM port A. Interrupt IRQ 4 IRQ 3 Selects the IRQ for COM port A. Serial Port B Disabled Enabled Auto OS Controlled Auto forces the BIOS to configure the port. OS Controlled is shown when the operating system controls the port. Setup Menus 89 3424.boo Page 90 Wednesday, September 2, 1998 9:23 AM Table 16: I/O Device Configuration Submenu (Continued) 90 Field Options Description Mode Normal IrDA ASK-IR Selects the mode for COM port B. Base I/O Address 3F8 2F8 3E8 2E8 Selects the base I/O address for COM port B. Interrupt IRQ 4 IRQ 3 Selects the interrupt for COM port B. Parallel Port Disabled Enabled Auto OS Controlled Auto forces the BIOS to configure the port. OS Controlled is shown when the operating system controls the port. Mode ECP Output only Bidirectional EPP Selects the mode for the parallel port. Base I/O Address 378 278 Selects the base I/O address for the parallel port. Interrupt IRQ 5 IRQ 7 Selects the interrupt for the parallel port. DMA channel DMA 1 DMA 3 Selects the DMA channel for the parallel port. Floppy disk controller Disabled Enabled Enables the onboard diskette controller. Base I/O Address Primary Secondary Sets the base I/O address for the diskette controller. PS/2 Mouse Auto Disabled Enabled Enables or disables the onboard mouse. Disabling the mouse frees IRQ 12. If this feature is set to Auto or Enabled, the operating system determines whether to enable or disable the mouse. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 91 Wednesday, September 2, 1998 9:23 AM Advanced Chipset Control Submenu The advanced chipset control submenu provides several fields that allow you to control various advanced features of the chipset. Table 17 lists the fields and the options for each. Table 17: Advanced Chipset Control Submenu Field Options Description Address Bit Permuting Disabled Enabled To be enabled, there must be a power of 2 number of rows (2, 4, 8, or 16), all rows must be the same size, and all populated rows must be adjacent and start at row 0. Two-way or four-way permuting is set automatically based on memory configuration. Base RAM Step 1 MB 1 KB Every location Tests base memory once per MB, once per KB, or at every location. Extended RAM Step 1 MB 1 KB Every location Tests extended memory once per MB, once per KB, or at every location. L2 Cache Enabled Disabled When enabled, the secondary cache is sized and enabled. For Core Clock Frequency-to-System Bus ratios equal to two, BIOS automatically disables the L2 cache. ISA Expansion Aliasing Enabled Disabled When enabled, every I/O access with an address in the range x100-x3FFh, x500-x7FFh, x900-xBFF, and xD00-xFFFh is internally aliased to the range 0100-03FFh before any other address range checking is performed. Memory Scrubbing Disabled Enabled When enabled, BIOS automatically detects and corrects single bit errors (SBEs). Restreaming Buffer Enabled Disabled When enabled, the data returned and buffered for a Delayed Inbound Read can be reaccessed following a disconnect. Read Prefetch for PXB0A N/A Informational field only. Configures the number of Dwords that are prefetched on Memory Read Multiple commands. Read Prefetch for PXB0B N/A Informational field only. Configures the number of Dwords that are prefetched on Memory Read Multiple commands. Setup Menus 91 3424.boo Page 92 Wednesday, September 2, 1998 9:23 AM Security Menu You can make the selections listed in Table 18 on the Security Menu. Enabling the Supervisor Password field forces you to enter a password to access Setup. Passwords are not case sensitive. Table 18: Security Menu Field Options Description Administrator Password is Clear Set Status only. Once set, you can disable the password by setting it to a null string (press ENTER without typing any other characters) or by clearing the password jumper on the system board (see “Security Add-in” on page 116 ). User Password is Clear Set Status only. Once set, you can disable the password by setting it to a null string or by clearing the password jumper on the system board (see “Security Add-in” on page 116). Set Administrative Password Press Enter When you press the ENTER key, you are prompted for a password; press the ESC key to cancel. Once set, you can disable the password by setting it to a null string or by clearing the password jumper on the system board (see “Security Add-in” on page 116). Set User Password Press Enter When you press the ENTER key, you are prompted for a password; press the ESC key to cancel. Once set, you can disable the password by setting it to a null string or by clearing the password jumper on the system board (see “Security Add-in” on page 116). Password on Boot Disabled Enabled If enabled and the user password is set, the system prompts you for a password before the system boots. Fixed Disk Boot Sector Normal Write Protect Write-protects the boot sector on the hard disk to protect against viruses. System Backup Reminder Disabled Daily Weekly Monthly Displays the system-backup reminder message at boot. Virus Check Reminder Disabled Daily Weekly Monthly Displays the virus-check reminder message at boot. Secure Mode Timer Disabled 1, 2, 5, 10, or 20 min 1 or 2 hr 92 Maintaining and Troubleshooting the Gateway ALR 9200 Server Defines the period of keyboard or PS/2 mouse inactivity specified for secure mode to activate. A password is required for secure mode to function. This field cannot be enabled unless at least one password is enabled. 3424.boo Page 93 Wednesday, September 2, 1998 9:23 AM Table 18: Security Menu (Continued) Field Options Description Secure Mode Hot Key (CTRL-ALT- ) [] [A, B, ..., Z] [0-9] Defines the key assigned to invoke the secure mode feature. You cannot enable this field unless at least one password is enabled. Disable this field by entering a new key followed by a backspace or by pressing the DELETE key. Secure Mode Boot Disabled Enabled Causes the system to boot in secure mode. You must enter a password to unlock the system. You cannot enable this field unless at least one password is enabled. Video Blanking Disabled Enabled Blanks the video when secure mode is activated. You must enter a password to unlock the system. You cannot enable this field unless at least one password is enabled. Floppy Write Protect Disabled Enabled When secure mode is activated, this field write protects the diskette drive. You must enter a password to reenable diskette writes. You cannot enable this field unless at least one password is enabled. Server Menu The server menu contains three fields that allow you to perform server specific management functions. Two of these fields open submenus. Table 19 lists the fields and the options available for each. Table 19: Server Menu Field Options Description System Management N/A Enters submenu. Console Redirection N/A Enters submenu. Processor Retest No Yes Instructs the BIOS to clear the historical processor status and to retest all processors on the next boot. Setup Menus 93 3424.boo Page 94 Wednesday, September 2, 1998 9:23 AM System Management Submenu The system management submenu provides eight fields that allow you to set system management characteristics. Table 20 lists the fields and the options for each. Table 20: System Management Submenu Field Options Description Server Management Mode Disabled Enabled Enabled loads the Server Management Interrupt handler, which handles system errors. System Event Logging Disabled Enabled Enabled forces the BIOS and the BMC to log system events. Clear Event Log Disabled Enabled Enabled clears the system event log. Assert NMI on AERR Disabled Enabled Enabled generates a nonmaskable interrupt (NMI) on an address parity error (AERR). Assert NMI on BERR Disabled Enabled Enabled generates an NMI on a bus error (BERR). Assert NMI on PERR Disabled Enabled Enabled generates an NMI on a parity error (PERR). To activate this feature, the system error (SERR) option must be enabled. Assert NMI on SERR Disabled Enabled Enabled generates an NMI on a SERR. Enabled Host Bus Error Disabled Enabled Enables host single-bit errors (SBEs) and multiplebit errors (MBEs). Console Redirection Submenu The console redirection submenu provides four fields that allow you to control the redirection of system management data to a remote console. Table 21 lists the fields and the options for each. Table 21: Console Redirection Submenu 94 Field Options Description COM Port Address Disabled 3F8 2F8 3E8 When enabled, console redirection uses the I/O port specified. When disabled, console redirection is completely disabled. IRQ # None, 3, or 4 When console redirection is enabled, this field displays the IRQ assigned based on the address chosen in the COM Port Address field. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 95 Wednesday, September 2, 1998 9:23 AM Table 21: Console Redirection Submenu (Continued) Field Options Description Baud Rate 9600 19.2k 38.4k 115.2k When console redirection is enabled, this field selects the baud rate. When the Emergency Management Port (EMP) shares the COM port as console redirection, the baud rate must be set to 19.2k to match the EMP baud rate, unless you use the autobaud feature. Flow Control No flow control CTS/RTS XON/XOFF CTS/RTS + CD None disallows flow control. CTS/RTS is hardware flow control. XON/XOFF is software flow control. CTS/RTS +CD is hardware plus carrier-detect flow control. Boot Menu The boot menu contains seven fields that allow you to control the boot process. Three of these fields open submenus. Table 22 lists the fields and the options for each. Table 22: Boot Menu Field Options Description Floppy Check Disabled Enabled If Enabled, system verifies the diskette type on boot. Disabled results in a faster boot. Multi-boot Support Disabled Enabled This option should remain enabled unless you install more than eight hard drives in the system. Boot Device Priority N/A Enters submenu. Hard Drive N/A Enters submenu. Removable Devices N/A Enters submenu. Maximum Number of I2O Drives 1 4 Selects the maximum number of I2O drives assigned a DOS drive letter. Message Timeout Multiplier 1, 2, 8, 10, 50, 100, 1000 All timeout values are multiplied by this number. Setup Menus 95 3424.boo Page 96 Wednesday, September 2, 1998 9:23 AM Boot Device Priority Submenu The boot device priority submenu allows you to set the relative priority of boot devices. The device identified as priority one is the first device searched for boot data. If that device does not have boot data or is not ready, the system looks for boot data on the second priority device and so on. Use the up- or down-arrow keys to select a device. Press the + or - keys to move the device higher or lower in the boot priority list. Table 23 shows the structure of the boot device priority submenu. Table 23: Boot Device Priority Submenu Priority Device Description 1. Diskette drive Attempts to boot from drive A. 2. Removable devices Attempts to boot from a removable media device 3. Hard drive Attempts to boot from a hard drive. 4. ATAPI CD-ROM drive Attempts to boot from an ATAPI CD-ROM drive Hard Drive Submenu The hard drive submenu allows you to set the priority of the hard drives in respect to the boot sequence. For options on this menu, use the up or down arrow keys to select a device. Press the + or - keys to move the device higher or lower in the boot priority list. Table 24 shows the manner in which the drives are displayed. Table 24: Hard Drive Submenu Boot Sequence Option Description 1. Drive #1 (or actual drive string) N/A 2. Other bootable drives (additional Covers all the boot devices that are not reported to entries for each drive that has a the system BIOS through the BIOS boot specification PnP header) mechanism. 96 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 97 Wednesday, September 2, 1998 9:23 AM Exit Menu The exit menu provides four commands. Select an option using the up or down arrow keys. Press ENTER to run the option. Pressing ESC does not exit this menu. You must select one of the items from the menu or menu bar to exit. Table 25 lists the options available and their functions. Table 25: Exit Menu Command Options Command Description Exit Saving Changes Exits after writing all modified Setup item values to NVRAM. Exit Discarding Changes Exits leaving NVRAM unmodified and continues POST. You are prompted if any of the Setup fields were modified. Load Setup Defaults Loads the default values for all Setup items. Load Custom Defaults Loads the settings from custom defaults. Setup Menus 97 3424.boo Page 98 Wednesday, September 2, 1998 9:23 AM Upgrading the BIOS Upgraded BIOS code is made available periodically. You should check the website regularly, especially if you have a problem with the server that is running BIOS Setup. Preparing for the Upgrade Before you upgrade the BIOS, prepare for the upgrade by recording the current BIOS settings, obtaining the upgrade utility, and making a copy of the current BIOS. Recording the Current BIOS Settings Remember to record the current BIOS settings. The upgrade process should preserve most settings, but some options may no longer be available or some options may change. Check the settings after the update to verify that the current settings are correct. To Record the Current BIOS Settings Note: Do not skip step 2. You will need these settings to configure your computer at the end of the procedure. 1. Boot the computer and press F2 when you see the message: Press Key if you want to run Setup 2. Write down the current settings from the BIOS Setup program. Obtaining the Upgrade Utility Note: Please review the instructions distributed with the upgrade utility before attempting a BIOS upgrade. You can upgrade to a new version of the BIOS using the new BIOS files and the BIOS upgrade utility, iFLASH.EXE. You can obtain the BIOS upgrade file and the iFLASH.EXE utility through your computer supplier or from the Intel World Wide Web site: http://www.intel.com. This upgrade utility allows you to: • • Upgrade the BIOS in flash memory. Update the language section of the BIOS. The following steps explain how to upgrade the BIOS. 98 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 99 Wednesday, September 2, 1998 9:23 AM Creating a Bootable Diskette The upgrade process requires you to boot the server from the diskette drive. You may need to redefine the boot sequence to set the diskette drive as the first priority boot device. To Create a Bootable Diskette 1. Use a DOS or Windows 95 system to create the diskette. 2. Insert a diskette in drive A. 3. At the C:\ prompt, for an unformatted diskette, type: format a:/s or, for a formatted diskette, type: sys a: 4. Press ENTER. Creating the BIOS Upgrade Diskette The BIOS upgrade file is a compressed self-extracting archive that contains the files you need to upgrade the BIOS. To Create the BIOS Upgrade Diskette 1. Copy the BIOS upgrade file to a temporary directory on your hard disk. 2. From the C:\ prompt, change to the temporary directory. 3. To extract the file, type the name of the BIOS upgrade file, for example: 10006BI1.EXE 4. Press ENTER. The extracted file contains the following files: LICENSE.TXT README.TXT BIOS.EXE Upgrading the BIOS 99 3424.boo Page 100 Wednesday, September 2, 1998 9:23 AM 5. Read the LICENSE.TXT file, which contains the software license agreement, and the README.TXT file, which contains the instructions for the BIOS upgrade. 6. Insert the bootable diskette into drive A. 7. To extract the BIOS.EXE file to the diskette, change to the temporary directory that holds the BIOS.EXE file and type: BIOS A: 8. Press ENTER. 9. The diskette now holds the BIOS upgrade and recovery files. Upgrading the BIOS The BIOS upgrade takes the server out of commission for a short time. Make sure that there are no running processes or other critical activities ongoing at the time you begin the BIOS upgrade. To Upgrade the BIOS 1. Boot the server with the diskette in drive A. The BIOS upgrade utility screen appears. 2. Select Update Flash Memory From a File. 3. Select Update System BIOS. Press ENTER. 4. Use the arrow keys to select the correct .bio file. Press ENTER. 5. When the utility asks for confirmation that you want to flash the new BIOS into memory, select Continue with Programming. Press ENTER. 6. When the utility displays the message that the upgrade is complete, remove the diskette. Press ENTER. 7. Reboot the server. As the server boots, check the BIOS identifier (version number) to verify that the upgrade was successful. 8. To enter the Setup program, press F2 when you see the message: Press Key if you want to run SETUP 100 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 101 Wednesday, September 2, 1998 9:23 AM 9. For proper operation, load the Setup program defaults. To load the defaults, press F9. 10. To accept the defaults, press ENTER. 11. Set the options in the Setup program to the settings you wrote down before the BIOS upgrade. 12. To save the settings, press F10. 13. To accept the settings, press ENTER. 14. Turn off the computer and reboot. Recovering the BIOS It is unlikely that anything will interrupt the BIOS upgrade; however, if an interruption occurs, the BIOS may be damaged. In that case, you must recover the BIOS. The procedure for recovering the BIOS is detailed in “Recovery Boot Jumper” on page 75. After performing the procedure, leave the upgrade disk in drive A and turn on the server, then continue with the BIOS upgrade (see “Upgrading the BIOS” on page 98). Note: Because of the small amount of code available in the nonerasable boot block area, there is no video support. You will see nothing on the screen during the procedure. Monitor the procedure by listening to the speaker and looking at the diskette drive LED. Changing the BIOS Language You can use the BIOS upgrade utility to change the language the BIOS displays. Use a bootable diskette containing the flash utility and language files (see “Creating the BIOS Upgrade Diskette” on page 99). To Change the BIOS Language 1. Boot the computer with the bootable diskette in drive A. The BIOS upgrade utility screen appears. 2. Select Update Flash Memory From a File. 3. Select Update Language Set. Press ENTER. 4. Select drive A and use the arrow keys to select the correct .lng file. Press ENTER. Upgrading the BIOS 101 3424.boo Page 102 Wednesday, September 2, 1998 9:23 AM 5. When the utility asks for confirmation that you want to flash the new language into memory, select Continue with Programming. Press ENTER. 6. When the utility displays the message upgrade is complete, remove the diskette. Press ENTER. 7. Reboot the computer and the changes will take effect. 102 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 103 Wednesday, September 2, 1998 9:23 AM Chapter 6: The Server Setup Utility Contents Introduction...................................................................104 Using the System Setup Utility ....................................105 When to Run the SSU...........................................105 What You Need to Do ..........................................106 Running the SSU ..........................................................107 Running the SSU Locally.....................................107 Running the SSU Remotely .................................107 Starting the SSU....................................................108 Customizing the SSU ...................................................109 Launching a Task..........................................................111 Resource Configuration Add-in Window....................112 Using the RCA Window.......................................112 Defining an ISA Board .........................................113 Adding and Removing ISA Boards .....................114 Modifying Resources............................................114 System Resource Usage .......................................115 Multiboot Options Add-in............................................115 Security Add-in.............................................................116 Security Options....................................................117 System Event Log Viewer Add-in...............................118 Sensor Data Record Manager Add-In..........................120 Field Replaceable Unit Manager Add-In.....................122 Exiting the SSU.............................................................124 3424.boo Page 104 Wednesday, September 2, 1998 9:23 AM Introduction This chapter describes the Power-on Self Test (POST) and system configuration utilities. These utilities are: • BIOS Setup: described in Chapter 5, “BIOS Setup” on page 79. If the system does not have a diskette drive, or the drive is disabled or misconfigured, use Setup to enable it. Or, you can move the CMOS jumper on the system board from the default setting (Protect CMOS memory) to the Clear setting; doing so allows most system configurations to boot. Then run the SSU to configure the system. • POST: described in Chapter 7, “Other Utilities” on page 125. POST checks basic system integrity and all major components. • Emergency Management Port (EMP) Console: described in Chapter 7, “Other Utilities” on page 125. Use the EMP to access and monitor the server remotely. • FRUSDR Load Utility: described in Chapter 7, “Other Utilities” on page 125. Use to update the Field Replacement Unit (FRU), Sensor Data Record (SDR), and Desktop Management Interface (DMI) flash components. • BIOS Update Utility: described in Chapter 7, “Other Utilities” on page 125. Use to update the BIOS or recover from a corrupted BIOS update. • Firmware Update Utility: described in Chapter 7, “Other Utilities” on page 125. Use to update the BMC flash ROM. • Symbios SCSI Utility: described in Chapter 7, “Other Utilities” on page 125. Use to configure or view the settings of the SCSI host adapters and onboard SCSI devices in the system. Use the SSU for extended system configuration of onboard resources and expansion cards, viewing the system event log (SEL), setting boot device priority, or setting system security options. Run the SSU from a set DOS-bootable diskettes. See “What You Need to Do” on page 106 to make a set of SSU diskettes. Information entered via the SSU overrides information entered via Setup. 104 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 105 Wednesday, September 2, 1998 9:23 AM Using the System Setup Utility The system setup utility (SSU) is provided on a set of diskettes shipped with the server. The SSU provides a graphical user interface (GUI) over an extensible framework for server configuration. The SSU framework supports the following functions and capabilities: • Assigns resources to system board devices and expansion cards before loading the operating system • • • Lets you specify boot device order and system security options • Allows troubleshooting of the server when the operating system is not operational • Provides a system-level view of the server I/O devices Permits viewing and clearing of the system event log (SEL) Permits viewing of the system field replaceable units (FRUs) and sensor data record (SDR). When to Run the SSU The SSU is a DOS-based utility that supports extended system configuration operations for onboard resources and expansion cards. Use the SSU when you need to: • Add and remove boards affecting the assignment of resources (ports, memory, IRQs, DMA) • • • • • • Modify the server boot device order or security settings Change the server configuration settings Save the server configuration View or clear the system event log (SEL) View FRU information View the SDR table If you install or remove an ISA expansion card, you must run the SSU to reconfigure the server. Running the SSU is optional for PCI and Plug and Play ISA expansion cards. Using the System Setup Utility 105 3424.boo Page 106 Wednesday, September 2, 1998 9:23 AM The SSU is PCI-aware and complies with the ISA Plug and Play specification; it works with any compliant configuration (.CFG) files supplied by the peripheral device manufacturer. The system board comes with a .CFG file describing the characteristics of the board and the system resources it requires. The configuration registers on PCI and ISA Plug and Play expansion cards contain the same type of information in a .CFG file. Some ISA boards also come with a .CFG file. The SSU uses the information provided by .CFG files, configuration registers, flash memory, and the information that you enter, to specify a system configuration. The SSU then writes the configuration information to flash memory. The configuration values in flash memory take effect when you boot the server. POST checks the values against the actual hardware configuration; if the values do not agree, POST generates an error message. You must then run the SSU to specify the correct configuration before the server boots. The SSU always includes a checksum with the configuration data so the BIOS can detect any potential data corruption before the actual hardware configuration takes place. What You Need to Do You must run the SSU from a set of DOS diskettes. You must follow the instructions in the included README.TXT file to prepare the diskettes. If your diskette drive is disabled or improperly configured, you must use the flash-resident Setup utility to enable it so you can use the SSU. If necessary, disable the drive after exiting the SSU. Information entered using the SSU overrides any entered using Setup. 106 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 107 Wednesday, September 2, 1998 9:23 AM Running the SSU The SSU can be run either locally (directly on the server you are configuring) or remotely (on a workstation connected to the server you are configuring through the network). Running the SSU Locally Running the SSU.BAT file starts the SSU. If the server boots directly from the SSU media, the SSU.BAT file runs automatically. If the server boots from different media, the SSU can be started manually or by another application. When the utility starts in the local execution mode (the default mode), the SSU accepts input from the keyboard and/or mouse. The SSU provides a VGA-based GUI on the primary monitor. The SSU runs from writable, nonwritable, removable, and nonremovable media. If the SSU is run from nonwritable media, user preference settings (like screen colors) cannot be saved. The SSU supports the ROM-DOS V6.22 operating system. It can run on other ROM-DOS compatible operating systems, but they are not supported. The SSU will not operate from a “DOS window” running under an operating system like Windows. Running the SSU Remotely To run the SSU remotely, you must invoke the SSU.BAT file with the /t switch and redirect the text-mode output via BIOS console redirect. See “Console Redirection Submenu” on page 94 for instructions on setting up the remote console. Running the SSU 107 3424.boo Page 108 Wednesday, September 2, 1998 9:23 AM Starting the SSU The SSU is a collection of task-oriented modules plugged into a common framework called the Application Framework (AF). The AF provides a launching point for individual tasks and a location for setting customization information. To Start the SSU 1. Turn on the video monitor and the system. 2. Start the SSU by inserting the bootable SSU diskette into drive A. Press the reset button or CTRL+ALT+DEL to reboot. When prompted to do so, press F2 to enter the BIOS Setup. From the boot menu, select the Boot Device Priority option. Select diskette drive as your primary boot device. Save those settings and exit the BIOS Setup. The server will boot from the diskette drive and display a menu of options. Follow the instructions in the menu to start the SSU. 3. When the SSU title appears on the screen, press ENTER to continue. 4. The mouse driver loads if it is available; press ENTER to continue. This message appears: Please wait while the Application Framework loads.... When the main window of the SSU appears (Figure 30), you can customize the user interface (UI) before continuing. See “Customizing the SSU” on page 109. 108 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 109 Wednesday, September 2, 1998 9:23 AM Figure 30: SSU Main Window Customizing the SSU You can customize the UI according to your preferences. The AF sets these preferences and saves them in the AF.INI file so that they take effect the next time you start the SSU. Use these four user-customizable settings: • Color—lets you change the default colors associated with different items on the screen to predefined color combinations. The changes are instantaneous. • Mode—lets you set the desired expertise level. • Novice • Intermediate • Expert Customizing the SSU 109 3424.boo Page 110 Wednesday, September 2, 1998 9:23 AM The expertise level determines which tasks are visible in the Available Tasks section and what actions each task performs. For a new mode setting to take effect, you must exit the SSU and restart it. In the current implementation, there is no distinction between these three different modes. • Language—lets you change the strings in the SSU to the appropriate language. For a new language setting to take effect, you must exit the SSU and restart it. • Other—lets you change other miscellaneous options in the SSU. The changes are instantaneous. To Change the Interface Default Values • Use the mouse to click on the proper button in the Preferences section of the SSU Main window. OR Note: If you run the SSU from nonwritable media (like a CD-ROM), these preferences are lost when you exit the SSU. 110 • Use the tab and arrow keys to highlight the desired button, and press the spacebar or ENTER. OR • Access the menu bar with the mouse or hot keys (ALT + the underlined letter). Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 111 Wednesday, September 2, 1998 9:23 AM Launching a Task It is possible to have many tasks open at the same time, although some tasks might require complete control to avoid possible conflicts. The tasks achieve complete control by commanding the center of operation until you close the task window. To Launch a Task • In the SSU Main window, double-click on the task name under Available Tasks to display the main window for that task. OR • Highlight the task name, and click OK. OR • Use the tab and arrow keys to highlight the desired button, and press the spacebar or ENTER. Launching a Task 111 3424.boo Page 112 Wednesday, September 2, 1998 9:23 AM Resource Configuration Add-in Window The resource configuration add-in (RCA) window provides three major functions: • Creates representations of devices that cannot be discovered by the system (ISA boards) • Modifies the contents of the system by adding and removing devices • Modifies the resources used by devices Using the RCA Window You can use the RCA window to define or add an ISA board by clicking on the appropriate button. To remove an ISA board, highlight the board in the Devices section of the screen before clicking on the button. You can add only as many ISA boards as there are ISA slots available. To Use the RCA Window 1. From the SSU main window, launch the RCA by selecting the Resources task under the RCA heading in the task box. 2. When the RCA window appears, it displays messages similar to the following: Baseboard: System Board PCI Card: Bus 00 dev 00 -– Host Processor Bridge PCI Card: Bus 00 dev 0D –- Multifunction Controller PCI Card: Bus 00 dev 0F –- Ethernet Controller PCI Card: Bus 00 dev 12 –- Multifunction Controller PCI Card: Bus 00 dev 14 –- VGA Controller 112 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 113 Wednesday, September 2, 1998 9:23 AM 3. To configure a device, click on it or select its name in the Devices section of the RCA window and press the spacebar or ENTER. 4. You can close the RCA window and return to the AF by clicking on the Close button. Any changes made are kept in memory for use by the RCA when it is rerun. 5. Save all changes by clicking Save. Saving writes your current configuration to nonvolatile storage where it is available to the system after every reboot. 6. Close the window by clicking on the system menu (the dash in the upper-left corner) to discard all changes that have not been saved. Defining an ISA Board An ISA board usually comes with a vendor-created .CFG file that specifies the resources the card requires to function properly. If the .CFG file is unavailable, you must manually create it or define the board through the SSU. Defining an ISA board consists of specifying the name of the board and the resources it consumes. This allows the RCA to consider the ISA board resource requirements when the RCA tries to resolve conflicts. BIOS also uses this information to configure hardware when the system is booted. To Define an ISA Board 1. To add or remove ISA board resources, click on the appropriate resource buttons, select the desired value, and click Add or Remove. 2. After you complete the necessary information, click Save. 3. To edit a board, click Load to retrieve the board information. After making changes, click Save. 4. To create a board, click New. 5. To remove a current definition of a board, click Delete. Resource Configuration Add-in Window 113 3424.boo Page 114 Wednesday, September 2, 1998 9:23 AM Adding and Removing ISA Boards Adding and removing boards through the RCA provides a way for the RCA to run its conflict detection algorithms on the resources requested by the boards. This alerts you to any possible problems with that particular board in the current configuration. To Add an ISA Board 1. Click Add ISA Board in the RCA window. 2. Specify the directory for the .CFG file. 3. Select the file and click OK. To Remove an ISA Board 1. Select a valid ISA board in the Devices section of the RCA window. 2. Click Remove ISA Board. Modifying Resources Modifying the resources of a device may be necessary to accommodate certain operating systems, applications, and drivers. You may also need to modify resources to resolve a conflict. To Modify Device Resources 1. Highlight the device in the Devices section of the RCA window. 2. Press the spacebar or ENTER, or double-click on the entry. This displays the functions of the selected device along with any possible choices and the resources associated with those choices. 114 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 115 Wednesday, September 2, 1998 9:23 AM To Edit Resources 1. Highlight the function in the Configuration window. 2. Press the spacebar or ENTER, or double-click on the entry (this updates the choice and resource lists). 3. Press the tab key to get to the choice list, and press ENTER. 4. Use the arrow keys to select a proper choice, and press ENTER again. 5. If the choice allows multiple possible values for a particular resource, use the hot key to select a resource and press the spacebar or doubleclick on the resource. 6. Select the desired resource, and click OK. System Resource Usage Click Resource Use in the Configuration window to display the System Resource Usage window, which shows the resources each device consumes. This information is useful if a conflict occurs. Devices can be organized according to the resources you want to examine using the options in the Resource section of the screen. The resource information can also be written to a plain text file through this window. Multiboot Options Add-in In this window, you can change the boot priority of a device. To Change the Boot Priority of a Device 1. Select a device. 2. Press + to move the device up in the list (higher priority). Press - to move it down. Multiboot Options Add-in 115 3424.boo Page 116 Wednesday, September 2, 1998 9:23 AM Security Add-in In this window, you can set the User and Administrator passwords and security options. To Set the User Password 1. Click User Password. 2. Enter the password in the first field. 3. Confirm the password by entering it again in the second field. To Change or Clear the User Password 1. Click User Password. 2. Enter the old password in the first field. 3. Enter the new password in the second field (or leave blank to clear). 4. Confirm the password by entering it again in the second field (or leave blank to clear). To Set the Administrator Password 1. Click Administrator Password. 2. Enter the password in the first field. 3. Confirm the password by entering it again in the second field. To Change or Clear the Administrator Password 1. Click Administrator Password. 2. Enter the old password in the first field. 3. Enter the new password in the second field (or leave blank to clear). 4. Confirm the password by entering it again in the second field (or leave blank to clear). 116 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 117 Wednesday, September 2, 1998 9:23 AM Security Options In this window, you can set the other security options: • Hot Key—sets a key sequence that puts the server into secure mode when the key is pressed. • Lock-Out Timer—sets an interval that puts the server into secure mode when no activity occurs during the interval. • Secure Boot Mode—forces the server to boot directly into secure mode. • Video Blanking—turns off the video when the server is in secure mode. • Floppy Write—controls access to the diskette drive when the server is in secure mode. • Reset/Power Switch Locking—controls the power and reset buttons when the server is in secure mode. Security Add-in 117 3424.boo Page 118 Wednesday, September 2, 1998 9:23 AM System Event Log Viewer Add-in Clicking on the system event log (SEL) add-in task brings up the SEL viewer add-in, which allows you to: • • Examine SEL records via the BMC in hex or verbose mode • Examine SEL records from a previously stored binary file in hex or verbose mode • Save SEL records to a file in either text or binary form • Clear SEL entries from the non-volatile storage area Examine SEL records by sensor or event type in hex or verbose mode The SEL viewer main window provides access to features of the add-in. Each option included on the main menu supports an accelerator key. Accelerator keys are indicated by an underlined letter in the text listing the option. The main window includes support to display the following information for each SEL entry: record identifier, event type, time stamp information, generator identifier, EMV revision, sensor type, sensor number, and event description. Figure 31 shows the SEL viewer main window. Table 26 lists the window’s menus and options. 118 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 119 Wednesday, September 2, 1998 9:23 AM Figure 31: SEL Viewer Add-in Main Window Table 26: SEL Viewer Menus and Options Menu Options File Open SEL: Views data from previously saved SEL file Save SEL: Saves the currently loaded SEL data to a file Clear SEL: Clears the SEL data from the BMC Exit: Quits the SEL Viewer View SEL Info: Displays information about the SEL (display only) All Events: Displays the current SEL data from the BMC By Sensor: Displays a pop-up menu allowing you to view the data from a certain sensor type By Event: Displays a pop-up menu allowing you to view the data from a certain event type Settings Display Hex/Verbose: Toggles between Hex/interpreted mode of displaying the SEL records Output Text/Binary: Determines whether SEL data is saved to the file (under File - Save) in binary format or verbose format Help About: Displays the SEL Viewer version information System Event Log Viewer Add-in 119 3424.boo Page 120 Wednesday, September 2, 1998 9:23 AM Sensor Data Record Manager Add-In In this window, you can: • Examine all SDR records through the BMC (in either Hex or Verbose mode) • Examine SDR records by Record type (in either Hex or Verbose mode) • Examine SDR records from a previously stored binary file (in either Hex or Verbose mode) • Save the SDR records to a file (in either text or binary form) The SDR Manager can display SDR records in either raw form (hexadecimal) or in an interpreted, easy-to-understand textual form (verbose). The SDR Manager’s main window provides access to features of the add-in through menus. Each option included on the main menu supports an accelerator key. Accelerator keys are indicated by an underlined letter in the text listing the option. Figure 32 shows the SDR Manager main window. Table 27 lists the window’s menus and options. 120 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 121 Wednesday, September 2, 1998 9:23 AM Figure 32: SDR Manager Main Window Table 27: SDR Manager Menus and Options Menu Options File Open FRU: Opens FRU data from a previously saved file Save SDR: Saves SDR data to a file in binary raw or verbose text format Exit: Quits the SDR Manager View SDR Info: Displays SDR information as returned by the GetSDRInfo interface of the BMC All Records: Displays all records in the SDR repository By Record: Displays all records in the SDR repository, sorted by record type Settings Display HEX: Displays SDR records in Hex format Display Verbose: Displays SDR records in verbose format Output Text: Saves SDR data in verbose format Output Binary: Saves SDR data in binary format Help About: Displays SDR Manager version information Sensor Data Record Manager Add-In 121 3424.boo Page 122 Wednesday, September 2, 1998 9:23 AM Field Replaceable Unit Manager Add-In In this window you can: • Examine all FRU Inventory areas on the server (in either Hex or Verbose mode) • Examine individual FRU Inventory areas (in either Hex or Verbose mode) • Examine FRU Inventory areas from a previously stored binary file (in either Hex or Verbose mode) • Save the FRU Inventory areas to a file (in either text or binary form) The FRU Manager can display the FRU Inventory areas in either raw form (hexadecimal) or in an interpreted, easy-to-understand textual form (verbose). The FRU manager’s main window provides access to features of the add-in through menus. Each option included on the main menu supports an accelerator key. Accelerator keys are indicated by an underlined letter in the text listing the option. Figure 33 shows the FRU Manager main window. Table 28 lists the window’s menus and options. 122 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 123 Wednesday, September 2, 1998 9:23 AM Figure 33: FRU Manager Main Window Table 28: FRU Manager Menus and Options Menu Options File Open FRU: Opens FRU data from a previously saved file Save FRU: Saves FRU data to a file in binary raw or verbose text format Exit: Quits the FRU Manager View FRU Info: Displays FRU information of the selected device All FRU Areas: Displays FRU areas of all devices By Device Type: Displays FRU areas sorted by device type Settings Display HEX: Displays FRU areas in Hex format Display Verbose: Displays FRU areas in verbose format Output Text: Saves FRU data in verbose format Output Binary: Saves FRU data in binary format Help About: Displays FRU Manager version information Field Replaceable Unit Manager Add-In 123 3424.boo Page 124 Wednesday, September 2, 1998 9:23 AM Exiting the SSU Exiting the SSU causes all windows to close. To Exit the SSU 1. Exit the SSU by opening the file menu in the SSU Main window. 2. Click Exit or Highlight Exit, and press ENTER. 124 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 125 Wednesday, September 2, 1998 9:23 AM Chapter 7: Other Utilities Contents Introduction.......................................................... 126 Power-on Self Test .............................................. 127 Emergency Management Port Console.............. 129 How the EMP Console Works..................... 130 EMP Console Requirements........................ 132 Setting Up the Server for the EMP .............. 133 Main EMP Console Window....................... 134 Server Control Operations ........................... 136 Phonebook .................................................... 140 Management Plug-ins .................................. 141 FRU and SDR Load Utility................................. 145 When to Run the FRUSDR Load Utility..... 145 What You Need to Do.................................. 145 How You Use the FRUSDR Load Utility... 146 Cleaning Up and Exiting.............................. 150 Using the Firmware Update Utility .................... 151 Running the Firmware Update Utility......... 151 Using the Symbios SCSI Utility ......................... 152 Running the SCSI Utility ............................. 152 3424.boo Page 126 Wednesday, September 2, 1998 9:23 AM Introduction This chapter describes the Power-on Self Test (POST) and system configuration utilities. These utilities are: 126 • POST: described in “Power-on Self Test” on page 127. POST checks basic system integrity and all major components. • BIOS Setup: described in Chapter 5, “BIOS Setup” on page 79. If the system does not have a diskette drive, or the drive is disabled or misconfigured, use Setup to enable it. Or, you can move the CMOS jumper on the system board from the default setting (Protect CMOS memory) to the Clear setting; doing so allows most system configurations to boot. Then run the SSU to configure the system. • Server Setup Utility (SSU): described in Chapter 6, “The Server Setup Utility” on page 103. Use for extended system configuration of onboard resources and expansion cards, viewing the system event log (SEL), setting boot device priority, or setting system security options. Run the SSU from a set DOS-bootable diskettes. See “What You Need to Do” on page 106 to make a set of SSU diskettes. Data entered in the SSU overrides data entered in Setup. • Emergency Management Port (EMP) Console: described in “Emergency Management Port Console” on page 129. Use the EMP to access and monitor the server remotely. • FRUSDR Load Utility: described in “FRU and SDR Load Utility” on page 145. Use to update the Field Replacement Unit (FRU), Sensor Data Record (SDR), and Desktop Management Interface (DMI) flash components. • BIOS Update Utility: described in “Upgrading the BIOS” on page 98. Use to update the BIOS or recover from a corrupted BIOS update. • Firmware Update Utility: described in “Using the Firmware Update Utility” on page 151. Use to update the BMC flash ROM. • Symbios SCSI Utility: described in “Using the Symbios SCSI Utility” on page 152. Use to configure or view the settings of the SCSI host adapters and onboard SCSI devices in the system. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 127 Wednesday, September 2, 1998 9:23 AM Power-on Self Test Each time you turn on the system, the power-on self test (POST) runs. POST checks the system board, processors, memory, keyboard, and most installed peripheral devices. During the memory test, POST displays the amount of memory it is able to access and test. The length of time needed to test memory depends on the amount of memory installed. POST is stored in flash memory. To Use POST 1. Turn on the monitor and the system. After a few seconds, POST begins to run. 2. After the memory test, these screen prompts and messages appear: Keyboard Detected Mouse Initialized Press to enter Setup 3. If you do not press F2 and there is no device with an OS loaded, the above message remains for a few seconds while the boot process continues, and the system beeps once. Then this message appears: Operating System not found If you do not press F2 and do have a device with an OS loaded, the boot process continues and this message appears: Press to enter SCSI Utility 4. Press CTRL+C if SCSI devices are installed. When the utility opens, follow the displayed instructions to configure the onboard SCSI host adapter settings and to run the SCSI utilities. Also see “Using the Symbios SCSI Utility” on page 152. If you do not enter the SCSI utility, the boot process continues. 5. Press ESC during POST to access a boot menu when POST finishes. From this menu, you can choose the boot device or enter BIOS Setup. Power-on Self Test 127 3424.boo Page 128 Wednesday, September 2, 1998 9:23 AM After POST completes, the system beeps once. What appears on the screen after this depends on if you have an OS loaded and if so, which one. If the system halts before POST completes running, it emits a beep code indicating a critical system error that requires immediate attention. If POST can display a message on the video display screen, the speaker beeps twice as the message appears. Note the screen display and write down the beep code you hear; this information is useful for your service representative. For a listing of beep codes and error messages that POST can generate, see “Solving Problems” on page 159. 128 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 129 Wednesday, September 2, 1998 9:23 AM Emergency Management Port Console The emergency management port (EMP) console provides an interface, called the console manager, to the EMP. This interface allows remote server management via a modem or direct connection. The EMP console must be run on a separate (client) system running either Windows 95 or Windows NT. The following server control operations are available with the console manager: • • • • Connecting to remote servers Powering the server on or off Resetting the server Switching the server console between EMP active and BIOS redirect modes The console manager uses three management plug-ins to monitor the server: the SEL, SDR, and FRU viewers. The console manager also has a support plug-in phonebook, which you can use to create and maintain a list of servers and their phone numbers. You can launch the Connect dialog directly from the Phonebook dialog to connect to a selected server. Emergency Management Port Console 129 3424.boo Page 130 Wednesday, September 2, 1998 9:23 AM How the EMP Console Works The EMP shares the COM2 port with the system. When the EMP has control of the port, the port operates in command state. When the system has control of it, the port operates in redirect state. When connecting to a server, the EMP console checks to determine the current COM2 port state. • Command state—the default COM2 state (Figure 34). In this state, the EMP console communicates with the server firmware, allowing the client to remotely reset or power the server up or down. The client can also view the server SEL, FRU information, or SDR table. Figure 34: EMP Console in Command State 130 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 131 Wednesday, September 2, 1998 9:23 AM • Redirect state—the EMP console serves as a PC ANSI terminal window for BIOS console redirection (Figure 35). Commands typed in this terminal window are transmitted through BIOS to the server console, and text displayed on the server console is displayed in the EMP console terminal window. With the EMP in this state, you can remotely view boot messages, access BIOS setup, and run DOS text mode applications through the EMP console terminal window. Figure 35: EMP Console in Redirect State Figure 35 shows the EMP console window in redirect state with the terminal window. The text that appears on the server monitor is also displayed in the redirect window. Availability of the various EMP console features is determined by two things: the EMP access mode selected during configuration in the System Management Submenu of the BIOS Server Menu (page 133) and whether the server COM2 port is configured for console redirect in the BIOS. Emergency Management Port Console 131 3424.boo Page 132 Wednesday, September 2, 1998 9:23 AM The three EMP access modes are disabled, pre-boot, and always active. Table 29: EMP Console Access Modes (Server Configured for Console Redirect) Mode Server is powered off During POST After Operating System boots Disabled Redirect window appears, but is blank Redirect window Redirect window Pre-boot EMP commands available Redirect window Redirect window Always Active EMP commands available Redirect window EMP commands available * You can modify the operation mode by selections in the POST reset and POST power-up dialogs. These are server control dialogs available with the EMP Console. Table 30: EMP Console Access Modes (Server not Configured for Console Redirect) Mode Server is powered off During POST After Operating System boots Disabled Redirect window appears, but is blank Redirect window appears, but is blank Redirect window appears, but is blank Pre-boot EMP commands available EMP commands available Redirect window appears, but is blank Always Active EMP commands available EMP commands available EMP commands available EMP Console Requirements This section outlines the requirements and configurations necessary for using the EMP console. Operating System, Windows NT: • • • Windows NT 4.0 or later 24 MB of RAM, 32 MB recommended 20 MB disk space Client Configuration: The EMP console supports all COM ports on the client system, along with any Windows NT/95 compatible modem. 132 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 133 Wednesday, September 2, 1998 9:23 AM Server Configuration: The EMP console requires that the server COM2 port be connected to an external modem or directly connected to a serial cable. Direct Connect Configuration: A null modem serial cable is needed. Connect one end of the cable into the COM2 port of the server and the other into a port on the client machine. Modem Configuration: On the client, the EMP console uses the Windows application program interface (API) to determine if a modem is connected and available. The EMP Console does not configure the modem; it should be preconfigured through Windows. For modem support, the server must use a Hayes-compatible 14400 bps modem. The modem must be on the NT hardware compatibility list provided by Microsoft. The server modem must be set in autoanswer mode for the EMP console to be able to connect to it. Setting Up the Server for the EMP To use the EMP, you must configure the BIOS with specific settings. Enter these settings in two submenus of the BIOS Server Menu: the System Management Submenu (“System Management Submenu” on page 94) and the Console Redirect Submenu (“Console Redirection Submenu” on page 94). The sections below focus on the settings that must be configured to use the EMP. System Management Submenu All EMP-related settings occur from the System Management Submenu of the server Main Menu. Change only the items below; all other default settings should remain the same. EMP Password: Any time you attempt to initiate a connection, a prompt for the user password appears. If you never set up the EMP password, anyone can access the EMP by clicking OK through the password prompt. In the EMP password area of the System Management Submenu, type in a password of up to eight alphanumeric characters. If the system beeps, the password was not accepted; you must enter a different password. Emergency Management Port Console 133 3424.boo Page 134 Wednesday, September 2, 1998 9:23 AM EMP Access Modes: Choose either disabled, pre-boot, or always active, depending on the type of EMP access needed. Table 29 on page 132 and Table 30 on page 132 list what is available with a given setting. EMP Restricted Mode Access: Set restricted mode to either enabled or disabled. In enabled mode, the EMP console server control options, Power On/Off and Reset, are NOT available. In disabled mode, these options are available. EMP Direct Connect/Modem Mode: Select Direct Connect if a null modem serial cable directly connects the server COM2 port to the EMP console client machine. If they are connected via a modem, select Modem Mode. Console Redirection Submenu To use the EMP, you must set the following options exactly as noted. COM Port Address: Select 2F8. This is the COM2 port that the EMP must use. The IRQ# setting is automatically assigned with the correct number based on the COM port address choice. Baud Rate: Select 19.2k. Console Type: Choose PC ANSI. Flow Control: Choose CTS/RTS + CD. Main EMP Console Window The main EMP console window provides a graphical user interface (GUI) to access server control operations and to launch the management plug-ins. A menu and tool bar at the top of the GUI provide options to initiate plugins and other support features. A status bar at the bottom displays connection information like server name, line status, and mode. 134 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 135 Wednesday, September 2, 1998 9:23 AM Toolbar The tool bar buttons (Table 31) combine server control and management plug-in options available from the Connect and Action menus. Table 31: Toolbar Buttons Connects to a selected server Disconnects from the currently connected server Powers the selected server on or off Resets the selected server Opens the SEL viewer Opens the SDR viewer Opens the FRU viewer Opens the Phonebook Opens online help Status Bar The status bar is displayed at the bottom of the current window. It contains the following status information: • • Server Name: The name of the connected server. Line: The type of line connection (direct or modem). Emergency Management Port Console 135 3424.boo Page 136 Wednesday, September 2, 1998 9:23 AM • Mode: Either redirect or EMP, depending on whether the EMP has control of the COM2 port. • Line Status: Gives status information on the server connection. For example, if a server is connected, the status bar says “Connected.” Otherwise, the line is blank. EMP Console Main Menu • File • • • • Exit: Exits the EMP console Connect • Disconnect: Disconnects the server connection. • [Re]Connect: Raises the connect dialog. • (A list of the five most recent connections): Initiates connection to selected server. Action • Power On/Off: Powers the server on or off with POST powerup options. • Reset: Resets the server with POST reset options. • SEL Viewer: Opens the SEL viewer. • SDR Viewer: Opens the SDR viewer. • FRU Viewer: Opens the FRU viewer. • Phonebook: Opens the phonebook dialog. Help: Provides version information and help topics for the EMP console. Server Control Operations Three server control operations are available from the menu or toolbar of the main EMP console window, remote server connection, powering the server on and off, and resetting the server. The server console mode can also be switched between EMP active and BIOS redirect modes through POST power-up and reset options. 136 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 137 Wednesday, September 2, 1998 9:23 AM Connect to Remote Server Select [Re]Connect from the Connect menu and follow the Connect dialog shown in Figure 36 allows you to connect to a selected server. If the client machine is already connected to a server, initiating connection generates a warning message. The message states that the existing connection will be terminated if you continue trying to initiate the new connection. You are prompted to enter the EMP password whenever a connection is attempted. Figure 36: Connect Dialog Options available in the dialog are: • Line Selection: Allows distinction between direct or dial-up modem connection to the server. • Dial-up: Connects to a selected server with a modem. • Direct connect (Serial Line): Connects to the selected server directly using a null modem serial cable. • Server: Displays a list of available servers in a dropdown edit list box. You can select or enter a server name; a server must be selected wen the line selection is dial-up. • Serial Line: Must be filled out when the line selection is set to direct connect (serial line). • Baud Rate: Specifies baud rate; must be 19200 for EMP to connect properly. • COM Port No.: Sets the COM port number to which the null modem serial cable is connected. Emergency Management Port Console 137 3424.boo Page 138 Wednesday, September 2, 1998 9:23 AM • Connect: Initiates connection to the server. When you click this button, you are prompted for the EMP password. • • • Config: Displays the Phonebook dialog. Cancel: Exit the Connect dialog with no action taken. Help: Display dialog-level help information. Power On/Off the Server Remotely Selecting Power On/Off from the Action Menu allows you to power the server on or off, with POST power-up options. It generates the Power on/off dialog (Figure 37). Figure 37: Power On/Off Dialog Options available in the dialog are: 138 • • Power ON: Powers on the server. • Post-power-up option: Sets the server mode EMP active or BIOS redirection. The setting is effective at the next power-up. The default selection is EMP active. • • Cancel: Exits the dialog with no action taken. Power OFF: Powers off the server. This option is not allowed if the server is configured in restricted mode for EMP operations. Help: Displays dialog-level help information. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 139 Wednesday, September 2, 1998 9:23 AM Reset the Server Remotely Selecting Reset from the Action Menu generates the Reset dialog (Figure 38) so that you can remotely reset the server with POST reset options. Figure 38: Reset Dialog Options available in the dialog are: • System Reset: Resets the server with the selected POST reset options. This operation is not allowed if the server is configured in restricted mode for EMP operations. • Option Group: Sets the POST reset option that will be effective after reset. The options are EMP active or BIOS redirection. The default selection is EMP active. • • Cancel: Exits the dialog with no action taken. Help: Displays dialog-level help information. Emergency Management Port Console 139 3424.boo Page 140 Wednesday, September 2, 1998 9:23 AM Phonebook The EMP console provides a phonebook (Figure 39), a support plug-in that stores names and numbers of servers in a list that can be updated by adding, modifying, or deleting entries. You can open the phonebook from the Main Menu and tool bars, or launch it by clicking the Config button. Figure 39: Phonebook Dialog Options available in the dialog are: 140 • Server: Displays a dropdown list of server names previously stored in the phonebook. If the New radio button is selected in the Operation area, the server area is cleared. • Phone No.: Displays the number of the selected server. If the New radio button is selected in the Operation area, this area is cleared. • Operation • New: Makes a new entry in the phonebook. Selecting this option clears the Server and Phone No. fields. You must click Save to add the entry to the phonebook. • Modify: Edits an existing entry. Before selecting this option, you must first select an existing entry from the Server dropdown edit box and modify the existing phone number. Click Save to store this entry in the phonebook. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 141 Wednesday, September 2, 1998 9:23 AM • Delete: Deletes an entry from the phonebook. You must first select an existing server from the Server dropdown edit box before selecting this option. Click Save to delete the entry. • Save: Saves a new or modified phonebook entry or deletes an entry if you have already selected the Delete radio button. • Connect: Raises the Connect dialog with the server from the phonebook Server dropdown edit box already populating the Connect dialog Server dropdown edit box. • • Cancel: Exits the dialog with no action taken. Help: Displays dialog-level help information. Management Plug-ins System Event Log Viewer The system event log (SEL) viewer can display records in either hexadecimal or text (verbose) form. These options are available through the SEL viewer: • • • • • • • • • • View the SEL from a file Save the SEL to a file View SEL summary information View all SEL entries View SEL info by event type View SEL info by sensor type Set SEL display mode to either Hex or verbose mode Set the SEL output file format to either text or binary format Close the SEL viewer Exit the EMP console Emergency Management Port Console 141 3424.boo Page 142 Wednesday, September 2, 1998 9:23 AM SEL Viewer Menu Options The following menu options are available on the SEL viewer menu bar: • • • • • • 142 File • Open: Allows you to view SEL data from a previously saved file if it was stored in binary format. Selecting the Open Menu item lets you specify a filename under which the data are found. The default filename is “SELLOG.DAT.” If the file cannot be opened, the program displays an error message. • Close: Closes the SEL viewer. • Save As: Dumps the SEL data to a file in either binary or text format. The binary file can be retrieved later. This option lets you specify a filename to which the data is saved. The default filename is “SELLOG.DAT.” If no data exist, the system displays an error message. • Exit: Exits the EMP console. Connect View • SEL Information: Displays SEL summary information. • All Events: Displays all events in the SEL. • By Sensor Type: Displays all events in the SEL generated by a specific sensor type, e.g., voltage, temperature, etc. • By Event: Displays all events in the SEL of a particular type, for example, by memory or threshold. A pop-up menu lets you select the event type to display. This menu displays all event types that can be generated by the hardware. Settings: Lets you change several operating parameters for the SEL viewer. This menu displays the following suboptions: • Display HEX/Verbose: Toggles between HEX mode and interpreted mode of displaying SEL records. • Output Text/Binary: Specifies whether SEL data is saved to the file in binary format or verbose format. Window: Gives options for displaying currently open windows. Help: Provides version information for the SEL viewer and provides help topics on the EMP console. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 143 Wednesday, September 2, 1998 9:23 AM Sensor Data Record Viewer The sensor data record (SDR) viewer lets you view the records retrieved from the SDR repository. Options available through the SDR viewer are: • • • • • • View all SDR records View SDR entries by SDR type View SDR summary information Set SDR display mode to either Hex or verbose mode Close the SDR viewer Exit the EMP console SDR Viewer Menu Options The SDR viewer menu bar contains the following: • File • • Close: Closes the SDR viewer. Exit: Exits the EMP console. • View • Display all Records: Displays all records from the SDRR. • SDR Type: Displays the records of a particular SDR type. Select an SDR type from a pop-up menu that displays all of the SDR types available for the hardware. • SDR Info: Displays the SDR summary information. • Settings: Lets you change operating parameters for the SDR viewer. This menu displays the following suboption: • Display HEX/Verbose: Toggles between HEX mode and interpreted mode of display. • • Window: Gives options for displaying currently open windows. Help: Provides version information for the SDR viewer and provides help topics on the EMP console. Emergency Management Port Console 143 3424.boo Page 144 Wednesday, September 2, 1998 9:23 AM FRU Viewer The FRU viewer lets you view data from the server system board FRU information area. Options available with the FRU viewer are: • • • • • View all FRU records View FRU summary information Set FRU display mode to either Hex or verbose mode Close the FRU viewer Exit the EMP console FRU Viewer Menu Options The following menu options are on the FRU viewer menu bar: • • • File • Close: Closes the FRU viewer. • Exit: Exits the EMP console. View • Display all Records: Displays all FRU data, which consist of chassis, board, and product information. • FRU Info: Displays the FRU summary information. Settings: Lets you change operating parameters for the FRU viewer. This menu displays the following suboption: • • • 144 Display HEX/Verbose: Toggles between HEX mode and interpreted mode of displaying FRU records. Window: Gives options for displaying currently open windows. Help: Provides version information for the FRU viewer and provides help topics on the EMP console. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 145 Wednesday, September 2, 1998 9:23 AM FRU and SDR Load Utility The Field Replacement Unit (FRU) and Sensor Data Record (SDR) load utility is a DOS-based program used to update the server management subsystem product level FRU, SDR, and the Desktop Management Interface (DMI) nonvolatile storage components. The utility: • Discovers the product configuration based on instructions in a master configuration file • • Displays the FRU information • Updates the DMI FRU area located in the BIOS nonvolatile storage device • Generically handles FRU devices that might not be associated with the BMC Updates the EEPROM associated with the system board management controller (BMC) that holds the SDR and FRU area When to Run the FRUSDR Load Utility You should run the FRUSDR load utility each time you upgrade or replace the hardware in your server, excluding expansion cards, hard drives, and RAM. For example, if you replace an array of fans, you need to run the utility. It programs the sensors that need to be monitored for server management. Because the utility must be reloaded to properly initialize the sensors after programming, turn the server off and remove the AC power cords from the server. Wait approximately 30 seconds, then reconnect the power cords and turn on the server. What You Need to Do You must run the utility from diskettes provided with the server and you must follow the instructions in the included README.TXT file. If the diskette drive is disabled, or improperly configured, you must use BIOS Setup to enable it. If necessary, you can disable the drive after you are done with the FRUSDR utility. FRU and SDR Load Utility 145 3424.boo Page 146 Wednesday, September 2, 1998 9:23 AM How You Use the FRUSDR Load Utility The utility: • Is compatible with ROM-DOS Ver. 6.22, MS-DOS Ver. 6.22, and later versions • Accepts CFG, SDR, and FRU load files (the executable file for the utility is frusdr.exe) • Requires the following supporting files • one or more .fru files describing the system field replaceable units • a .cfg file describing the system configuration • an .sdr file describing the sensors in the system Command Line Format The command line uses several keys. Table 32 lists the keys and their definitions. The basic command line format is frusdr [-?] [-h] [-d {dmi, fru, sdr}] [-cfg filename.cfg] [-fru filename.fru] Table 32: Command Line Format Elements Command Description frusdr Is the name of the utility -? or -h Displays usage information -d {dmi, fru, sdr} Displays requested area only -cfg filename.cfg Uses custom CFG file -p Pause between blocks of data -v Verbose, display any additional details Parsing the Command Line The FRUSDR load utility allows only one command line function at a time. A command line function can consist of two parameters. Example: -cfg filename.cfg. Invalid parameters cause an error message and exit the 146 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 147 Wednesday, September 2, 1998 9:23 AM program. You can use either a slash (/) or a minus sign (-) to specify command line options. The -p and -v flags can be used in conjunction with any of the other options. Displaying Usage Information When the utility is run with the -? or -h command line flags, the following message is displayed when the verbose flag -v is added to the help command: FRU & SDR Load Utility Version 2.1 Revision R.1.1 Copyright (c) 1998, Intel Corporation, All Rights Reserved This utility must be run from a system executing DOS. Running in a Windows DOS box is insufficient and provides incorrect results. Programming the BMC FRU area clears the SDR table; therefore the SDR table must be reprogrammed. Upon completing the programming of the FRU and SDR areas, the server should be rebooted. The system displays the following information if the -v option is included in the command line. The /D FRU command may be followed with up to 16 device addresses. These device addresses are used to view up to 16 different FRU areas, instead of the default of displaying the BMC FRU. The arguments following the "-d FRU" are in the same order and value as the NVS_TYPE, NVS_LUN, DEV_BUS and DEV_ADDRESS which are found in the FRU file header in each FRU file. The LUN address is optional. If the LUN address is used, it must start with an ’L’. Usage: Example: FRUSDR -d fru (device) [lun] (bus) (addr) (addr2) (etc) FRUSDR /D FRU IMBDEVICE L00 00 C0 C2 The configuration file may be used to load multiple FRU and SDR files. In the configuration file, you may define which FRU and SDR areas are to be programmed. Additionally, you may request information from the user or ask the user to choose which areas to program. FRU and SDR Load Utility 147 3424.boo Page 148 Wednesday, September 2, 1998 9:23 AM Displaying a Given Area When the utility is run with the -d DMI, -d FRU, or -d SDR command line flag, the indicated area is displayed. Each area represents one sensor for each instrumented device in the server. If the given display function fails because of an inability to parse the data present or a hardware failure, the utility displays an error message and exits. Displaying the DMI Area Each DMI area displayed is headed with the DMI area designated name. In each area, each field has a field name header followed by the field in ASCII or as a number. Example: To display the DMI area, type frusdr -d dmi and press ENTER. Displaying the FRU Area The FRU area is displayed in ASCII format when the field is ASCII or as a number when the field is a number. Each FRU area displayed is headed with the FRU area designated name. Each field has a field name header followed by the field in ASCII or as a number. The board, chassis, and product FRU areas end with an END OF FIELDS CODE that indicates there are no more data in the area. The internal use area is displayed in hex format, 16 bytes per line. Example: To display the FRU area, type frusdr -d fru and press ENTER. Displaying the SDR Area The SDR nonvolatile storage area is displayed in hex format. The data are separated by a sensor record number X header, where X is the number of that sensor record in the SDR area. The next line after the header is the sensor record data in hex format delineated by spaces. Each line holds up to 148 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 149 Wednesday, September 2, 1998 9:23 AM 16 bytes. The data on each line are followed by the same data in ASCII format; nonprintable characters (ch < 32 || ch > 126) are substituted by a period (.). Example: To display the SDR area, type frusdr -d sdr and press ENTER. Using a Specified CFG File The utility can be run with the command line parameter of -cfg filename.cfg. The filename can be any DOS-accepted, eight-character filename string. The utility loads the specified CFG file and uses the entries in that file to probe the hardware and to select the proper SDRs to load into nonvolatile storage. Displaying the Utility Title and Version The utility displays its title: FRU & SDR Load Utility, Version 2.0, Revision X.XX where X.XX is the revision number for the utility. Configuration File The configuration file is in ASCII text. The utility executes commands formed by the strings present in the configuration file. These commands cause the utility to run tasks needed to load the proper SDRs into the nonvolatile storage of the BMC and possibly generic FRU devices. Some of the commands may be interactive and require you to make a choice. Prompting for Product Level FRU Information Through the use of a configuration file, the utility might prompt you for FRU information. FRU and SDR Load Utility 149 3424.boo Page 150 Wednesday, September 2, 1998 9:23 AM Filtering Records From the SDR File The MASTER.SDR file has all the possible SDRs for the system. These records might need to be filtered based on the current product configuration. The configuration file directs the filtering of the SDRs. Updating the SDR Nonvolatile Storage Area After the utility validates the header area of the supplied SDR file, it updates the SDR repository area. Before programming, the utility clears the SDR repository area. The utility filters all tagged SDRs depending on the product configuration set in the configuration file. Nontagged SDRs are automatically programmed. The utility also copies all written SDRs to the SDR.TMP file; it contains an image of what was loaded. The TMP file is also useful for debugging the server. Updating the FRU Nonvolatile Storage Area After the configuration is determined, the utility updates the FRU nonvolatile storage area. First it verifies the common header area and checksum from the specified FRU file. The internal use area is read out of the specified.FRU file and is programmed into the nonvolatile storage. The chassis area is read out of the specified.FRU file. Finally, it reads the product area out of the specified FRU file, then the area is programmed into the FRU nonvolatile storage. All areas are also written to the FRU.TMP file. Updating the DMI FRU Nonvolatile Storage Area After programming the BMC FRU area, the utility programs chassis, board, and product FRU information to the DMI fields, if the DMI flag follows each FRUAREA command in the configuration file. Cleaning Up and Exiting If an update was successfully performed, the utility displays a single message and then exits. If the utility fails, it immediately exits with an error message and exit code. 150 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 151 Wednesday, September 2, 1998 9:23 AM Using the Firmware Update Utility The Firmware Update Utility (FUU) is a DOS-based program used to update the BMC firmware code. Running the Firmware Update Utility You need to run the firmware update utility (FUU) only if new firmware code is necessary. To Run the FUU 1. Create a DOS-bootable diskette. The version of DOS must be 6.0 or higher. 2. Place the firmware update utility (FWUPDATE.EXE) and the *.hex file on the diskette. Make a note of the *.hex file name, because you will need it later. 3. Insert the diskette into drive A and boot to it. 4. At the DOS prompt, run the executable file (FWUPDATE.EXE). 5. The utility displays a menu screen. Select Upload Flash. 6. The utility asks for a file name. Enter the name of the *.HEX file. 7. The program loads the file and then asks if it should upload the boot block. Press N to continue. 8. The program next asks if it should upload the operational code. Press Y to continue. 9. Once the operational code has been updated and verified, press any key to continue. Then press ESC to exit the program. 10. Shut the system down and remove any diskettes in the system. 11. Disconnect all AC power cords from the system and wait 60 seconds. 12. Reconnect the AC power cords and power up the system. Using the Firmware Update Utility 151 3424.boo Page 152 Wednesday, September 2, 1998 9:23 AM Using the Symbios SCSI Utility The Symbios SCSI utility detects the SCSI host adapters on the system board. Use the utility to: • • Change default values Check and/or change SCSI device settings that may conflict with those of other devices in the server Running the SCSI Utility When this message appears on the monitor: Press Ctrl-C to run SCSI Utility... Press CTRL+C to run the utility. When it appears, choose the host adapter that you want to configure. 152 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 153 Wednesday, September 2, 1998 9:23 AM Chapter 8: Troubleshooting Contents Introduction.......................................................... 154 Computer Virus Notice ....................................... 155 Viruses .......................................................... 155 Types of Viruses........................................... 155 Virus Contamination .................................... 155 Protecting Your System ............................... 156 Virus Prevention........................................... 156 Troubleshooting Checklist .................................. 158 Verifying the Configuration......................... 158 Troubleshooting Guidelines......................... 158 Solving Problems................................................. 159 Resetting the System .................................... 159 Initial System Startup ................................... 159 Running New Application Software ........... 160 The System Has Been Running Correctly... 161 More Problem-solving Procedures.............. 162 Specific Problems and Corrective Actions.. 164 Error and Informational Messages...................... 170 POST Codes and Countdown Codes........... 170 POST Error Codes and Messages................ 173 3424.boo Page 154 Wednesday, September 2, 1998 9:23 AM Note: Under no circumstances return any equipment without obtaining a Return Material Authorization (RMA) number. 154 Introduction If your system does not operate correctly, re-read the instructions for the procedure(s) you have performed. If an error occurs within an application, consult the documentation supplied with the software. This section identifies solutions to common problems. If the suggestions in this chapter do not resolve your problem, try calling Technical Support. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 155 Wednesday, September 2, 1998 9:23 AM Computer Virus Notice Viruses A virus is a program written with malicious intent for the sole purpose of creating havoc in a computer system. It attaches itself to executable files or boot sectors, so it can replicate and spread. Some viruses may only cause your system to beep or display messages or images on the screen. Other viruses are highly destructive and corrupt or erase the contents of your files or disks. To be safe, never assume any virus is harmless. Types of Viruses Viruses are identified by how they infect computer systems. • Program viruses infect executable program files such as .com, .exe, .ovl, .drv, .sys, and .bin. • Macro viruses infect macro files of programs such as word processing and spreadsheet programs. • Boot viruses attach themselves to a boot record, master boot, FAT, or partition table. • Multipartite viruses are both program and boot infectors. Virus Contamination There are many ways a virus can spread and infect your system. However, a virus is inactive until the infected program is executed, or a boot record is read. Thereafter, the virus loads itself into system memory and begins to copy and spread itself. Disks used in a contaminated system can get infected and, in turn, transfer the virus when used in another system. A virus can also spread via programs downloaded from bulletin boards or the Internet. Remember that viruses cannot appear all by themselves. They have to be written, then spread through direct contact with executable programs or boot sectors. Computer Virus Notice 155 3424.boo Page 156 Wednesday, September 2, 1998 9:23 AM Protecting Your System Awareness is the key. You need to learn about the existence of viruses, how they spread, and what to do to protect your system by reducing the likelihood of virus contamination. The following may help: • Obtain an anti-virus program and make it a habit to scan the system regularly. These programs may be purchased from a local software store or obtained via shareware on the Internet or online service providers such as CompuServe, Prodigy, AOL, or DeltaNet. • Make backup copies of all files and write-protect the disks. • Obtain all software from reputable sources and always scan new software for any viruses before installing files. If you suspect your system has been infected, you must find and remove the viruses immediately using an anti-virus program. Next, reboot your system as follows: shut the system down, then turn it off for at least 15 seconds before turning it back on. This is the only way to ensure the virus does not remain in your system RAM. Virus Prevention We stand by the integrity of our products. Our staff takes every precaution to ensure our files are free from viruses. These precautions include the following: 156 • We use McAfee VirusScan, a leading anti-virus software that detects and removes over 95% of known viruses and provides comprehensive protection including local and network drives, CDROMs, floppies, boot sectors, and partition tables. VirusScan also provides advanced protection against unknown viruses. We continuously update and use the most current version of McAfee VirusScan on all of our products. • All master disks are write-protected and scanned at least twice before release. • Sample production disks are periodically scanned as an additional quality check. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 157 Wednesday, September 2, 1998 9:23 AM • All incoming products such as systems to repair, vendor disks, hard drives, and trade-show units are scanned for viruses. • All systems are given a final test before shipping. Unfortunately, today’s technology makes the creation of newer viruses possible, some of which can elude even the best scanners available. Hence, there is no absolute guarantee of virus immunity on any product. If you think you have received an infected product from us, please contact Technical Support. Our staff will assist you in correcting the problem. Computer Virus Notice 157 3424.boo Page 158 Wednesday, September 2, 1998 9:23 AM Troubleshooting Checklist Before turning on the system, make sure that: • The power cord is connected to the AC power-in connector and an AC outlet. • • • The AC outlet is supplying power. If a power strip is used, it is turned on, and the circuit breaker is set. The voltage selection switch on the system power supply reflects the proper voltage. Verifying the Configuration If your system is not operating correctly, the BIOS may contain an invalid configuration parameter. Enter the BIOS program and check your configuration settings, see “BIOS Setup” on page 79 for complete instructions. Troubleshooting Guidelines As you troubleshoot your system, keep the following guidelines in mind: 158 • • Never remove the system cover while the system is turned on. • If a peripheral such as the keyboard, mouse, drive, or printer does not appear to work, verify that all connections are secure. • If an error message displays on the screen, write it down, word for word. You may be asked about it when calling Technical Support. • • Only qualified personnel should open the system for maintenance. Do not attempt to open the monitor; it is extremely dangerous. Even if the monitor’s power is disconnected, stored energy within the monitor’s components can offer a painful or harmful experience. If you feel you are qualified to maintain the system yourself, make certain you are properly grounded before opening the system chassis. See Chapter 1, “System Access”, for more information on preventing electrostatic damage to the system. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 159 Wednesday, September 2, 1998 9:23 AM Solving Problems This chapter helps you identify and solve problems that might occur while you are using the system. Resetting the System Some problems can be solved simply by resetting the system. A system reset clears memory, and resets many registers to initial startup values. If the data in memory or any registers has become corrupt or has been improperly set during operation, a system reset will correct the problem. Table 33 lists the various ways in which the system can be reset. Table 33: System Reset Methods Key or Button Type of Reset CTRL+ALT+DEL Soft boot reset, which clears system memory and reloads the operating system. Reset button Clear system memory, restart POST, and reload the operating system. Power off/on Cold boot reset, which clears system memory, restarts POST, reloads the operating system, and halts power to all peripherals. Initial System Startup Problems that occur at initial system startup are usually caused by incorrect installation or configuration. Hardware failure is a less frequent cause. Checklist • • • • Are all cables correctly connected and secured? • Are all switch and jumper settings on the system board correct? Are all cables correctly connected and secured? Are the processors fully seated in their slots on the system board? Are all ISA and PCI cards fully seated in their slots on the system board? Solving Problems 159 3424.boo Page 160 Wednesday, September 2, 1998 9:23 AM • Are all jumper and switch settings on expansion cards and peripheral devices correct? To check these settings, refer to the manufacturer’s documentation that comes with them. If applicable, ensure that there are no conflicts—for example, two expansion cards sharing the same interrupt. • • • Are all DIMMs installed correctly? • • • Are all device drivers properly installed? • Did you press the system power on/off switch on the front panel to turn the server on (power-on light should be lit)? • Are the system power cords properly connected to the system and plugged into a NEMA 5-15R outlet for 100-120 V∼ or a NEMA 615R outlet for 200-240 V∼? • • Is AC power available at the wall outlet? Are all peripheral devices installed correctly? If the system has a hard disk drive, is it properly formatted or configured? Are the configuration settings made with the SSU correct? Is the operating system properly loaded? Refer to the operating system documentation. If these items are correct but the problem recurs, see “Solving Problems” on page 159. Running New Application Software Problems that occur when you run new application software are usually related to the software. Faulty equipment is much less likely, especially if other software runs correctly. Checklist 160 • Does the system meet the minimum hardware requirements for the software? See the software documentation. • Is the software an authorized copy? If not, get one; unauthorized copies often do not work. • If you are running the software from a diskette, is it a good copy? Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 161 Wednesday, September 2, 1998 9:23 AM • If you are running the software from a CD-ROM disk, is the disk scratched or dirty? • If you are running the software from a hard disk drive, is the software correctly installed? Were all necessary procedures followed and files installed? • • • • Are the correct device drivers installed? Is the software correctly configured for the system? Are you using the software correctly? If the problems persist, contact the software vendor’s customer service representative. The System Has Been Running Correctly Problems that occur after the system hardware and software have been running correctly often indicate equipment failure. Many situations that are easy to correct, however, can also cause such problems; sometimes the problem stems from changes made to the system, such as hardware or software that has been added or removed. Checklist • If you run the software from diskette, use a new copy of the software. • If you run the software from a CD-ROM, try a different disc to see if the problem occurs on all disks. • If you run the software from a hard drive, run it from a diskette. If the software runs correctly, there is a problem with the copy on the hard drive. Reinstall the software on the hard drive, and run it again. Make sure all necessary files are installed. • If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard input is incorrect), a marginal power supply, or other random component failures. • If you suspect that a transient voltage spike, power outage, or brownout may have occurred, reload the software and run it again. (Symptoms of voltage spikes include a flickering video display, unexpected system reboots, and failure to respond to commands.) Note: If you are getting random errors in your data files, they may be getting corrupted by voltage spikes on your power line. If you are experiencing any of the symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cords. Solving Problems 161 3424.boo Page 162 Wednesday, September 2, 1998 9:23 AM More Problem-solving Procedures This section provides a more detailed approach to identifying a problem and locating its source. Preparing the System for Diagnostic Testing If the checks described in the preceding pages do not correct the problem, you may need to run some diagnostics programs. Most diagnostics programs require rebooting or the closure of all running software. To Run Diagnostics Caution! Before disconnecting any peripheral cables from the system, turn off the system and any external peripheral devices. Failure to do so can cause permanent damage to the system and/or the peripheral devices. 1. Turn off the system and all external peripheral devices. Disconnect all of them from the system, except the keyboard and video monitor. 2. Make sure the system power cords are plugged into a properly grounded AC outlet. 3. Make sure your video display monitor and keyboard are correctly connected to the system. Turn on the video monitor. Set its brightness and contrast controls to at least two-thirds of their maximum ranges (see the documentation supplied with your video display monitor). 4. If the operating system normally loads from the hard disk drive, make sure there is no diskette in drive A. Otherwise, place a diskette containing the operating system files in drive A. 5. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on page 164. 162 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 163 Wednesday, September 2, 1998 9:23 AM Using PCDiagnostics A diagnostics package for the system is provided with the system. For documentation about the test modules, see the Diagnostic help files that end with the extension .HLP. They are ASCII files that you can print to form a manual of all tests in this product. • The program called Testview uses a simple DOS-based menu system. • The program called T.EXE is not for Windows or DOS; you can access it at the command line prompt without having a hard drive installed. • The README.TXT file for diagnostics tells how to install the program. Monitoring POST Caution! The diagnostic package contains many optional tests that should be used only by a user with advanced technical knowledge. Inadvertent actions could be damaging, such as running a hard drive write test on a hard disk. All tests that require external hardware, user interaction, or are destructive, are disabled in the default configurations. Before using such a test, make sure you read and understand the help information for that test. See “Power-on Self Test” on page 127, for more information about the POST utility and its functions. Verifying Proper Operation of Key System Lights As POST determines the system configuration, it tests for the presence of each mass storage device installed in the system. As each device is checked, its activity light should turn on briefly. Check for the following: • Does the diskette drive activity light turn on briefly? If not, see “Diskette Drive Activity Light Does Not Light” on page 167. • If a second diskette drive is installed, does its activity light turn on briefly? If not, see “Diskette Drive Activity Light Does Not Light” on page 167. • If there is a hard disk drive or SCSI devices installed in the system, does the hard disk drive activity light on the control panel turn on briefly? If not, see “Hard Disk Drive Activity Light Does Not Light” on page 168. Solving Problems 163 3424.boo Page 164 Wednesday, September 2, 1998 9:23 AM Confirming the Loading of the Operating System Once the system boots, the operating system prompt appears on the screen. The prompt varies according to the operating system. If the operating system prompt does not appear, see “Initial System Startup” on page 159. Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • • • • • • • • • • Power light does not light. • The bootable CD-ROM is not detected. No beep or incorrect beep pattern. No characters appear on screen. Characters on the screen appear distorted or incorrect. System cooling fans do not rotate. Diskette drive activity light does not light. Hard disk drive activity light does not light. CD-ROM drive activity light does not light. Problems with application software. The startup prompt “Press key if you want to run Setup” does not appear on the screen. Try the solutions in the order given. If you cannot correct the problem, contact Technical Support for assistance. Power Light Does Not Light Check the following: 164 • Are all the power supplies plugged in? Is the power turned on to the power strip or outlet? Do you have a blown fuse or breaker? • Is the system operating normally? If so, the power LED may be defective or the cable from the front panel to the system board may be loose. • Are there other problems with the system? If so, look under “System Cooling Fans Do Not Rotate Properly” on page 166. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 165 Wednesday, September 2, 1998 9:23 AM If all items are correct and problems persist, contact Technical Support for assistance. No Beep Codes If the system operates normally, but there was no beep, the speaker may be defective. If the speaker is enabled, but the speaker does not function, contact Technical Support for assistance. No Characters Appear on Screen Check the following: • Is the keyboard working? Check to see that the “Num Lock” light is functioning. • Is the video monitor plugged in and turned on? Many modern video monitors shut down when inactive and may require a moment to warm up when activated. • Are the brightness and contrast controls on the video monitor properly adjusted? • • • Are the video monitor switch settings correct? Is the video monitor signal cable properly installed? Is the onboard video controller enabled? If you are using an add-in video controller board, you may need to perform some additional checks. To Test an Add-in Video Controller 1. Verify that the video controller board is fully seated in the system board connector (and verify that the video monitor is plugged in to the active video controller). 2. Reboot the system for changes to take effect. Solving Problems 165 3424.boo Page 166 Wednesday, September 2, 1998 9:23 AM 3. If there are still no characters on the screen after you reboot the system and POST emits a beep code, write down the beep code you hear. This information is useful for your service representative. See “POST Codes and Countdown Codes” on page 170. 4. If you do not receive a beep code and characters do not appear, the video display monitor or video controller may have failed. You can verify this by trying the monitor on another system or trying a different monitor on this system. Contact Technical Support for assistance. Characters Are Distorted or Incorrect Check the following: • Are the brightness and contrast controls properly adjusted on the video monitor? See the manufacturer’s documentation. • • Are the video monitor signal and power cables properly installed? Is the correct monitor/video board installed for your operating system? If the problem persists, the video monitor may be faulty or it may be the incorrect type. Contact Technical Support for assistance. System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, system components could be damaged. Check the following: 166 • • Is AC power available at the wall outlet? • • Did you press the power on/off push-button switch? Are the system power cords properly connected to the system and the wall outlet? Is the power-on light lit? Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 167 Wednesday, September 2, 1998 9:23 AM • Have any of the fan motors stopped (use the server management subsystem to check the fan status)? • Are the fan power connectors properly connected to the system board? • Is the cable from the front panel board connected to the system board? • Are the power supply cables properly connected to the system board? • Are there any shorted wires caused by pinched cables or power connector plugs forced into power connector sockets the wrong way? If the switches and connections are correct and AC power is available at the wall outlet, contact Technical Support for assistance. Diskette Drive Activity Light Does Not Light Check the following: • • Are the diskette drive power and signal cables properly installed? • • Is the diskette drive properly configured? Are all relevant switches and jumpers on the diskette drive set correctly? Is the diskette drive activity light always on? If so, the signal cable may be plugged in incorrectly. If you are using the onboard diskette controller, use the SSU to make sure that Onboard Floppy is set to Enabled. If you are using an add-in diskette controller, make sure that Onboard Floppy is set to Disabled. To run the SSU, see “Using the System Setup Utility” on page 105. If the problem persists, there may be a problem with the diskette drive, system board, or drive signal cable. Contact your service representative or authorized dealer for assistance. Solving Problems 167 3424.boo Page 168 Wednesday, September 2, 1998 9:23 AM Hard Disk Drive Activity Light Does Not Light Note: The hard disk drive activity light on the front panel lights when either an IDE hard disk drive, or a SCSI device controlled by the onboard SCSI host controller, is in use. This LED does not display CD-ROM activity. If you have installed one or more hard disk drives in your system, check the following: • • Are the power and signal cables to the drive properly installed? • • Is the onboard IDE controller enabled? (IDE hard drives only) Are all relevant switches and jumpers on the hard drive and adapter board set correctly? Is the hard disk drive properly configured? CD-ROM Drive Activity Light Does Not Light Check the following: • Are the power and signal cables to the CD-ROM drive properly installed? • • • Are all relevant switches and jumpers on the drive set correctly? Is the drive properly configured? Is the onboard IDE controller enabled? Network Problems If you have network problems, consult the documentation that came with the network board installed in the server. PCI Installation Tips Some common PCI tips are listed here. • 168 Reserve interrupts (IRQs) and/or memory addresses specifically for ISA adapters. This prevents PCI boards from trying to use the same settings ISA boards are using. Use the SSU to keep track of ISA adapter resources. Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 169 Wednesday, September 2, 1998 9:23 AM • Certain drivers may require interrupts that are not shared with other PCI drivers. You can use the SSU to adjust the interrupt numbers for PCI devices. For certain drivers, it may be necessary to alter settings so that interrupts are not shared. • Check PCI interrupt interdependencies among slots and onboard devices. Problems with Application Software If you have problems with application software, do the following: • Verify that the software is properly configured for the system. See the software installation and operation documentation for instructions on setting up and using the software. • Try a different copy of the software to see if the problem is with the copy you are using. • • Make sure all cables are installed correctly. • If other software runs correctly on the system, contact your vendor about the failing software. Verify that the system board jumpers are set correctly. See “Setting the Jumpers” on page 72. If the problem persists, contact the software vendor’s customer service representative for assistance. Bootable CD-ROM Is Not Detected Check the following: • Is the BIOS set to allow the CD-ROM to be the first bootable device? Solving Problems 169 3424.boo Page 170 Wednesday, September 2, 1998 9:23 AM Error and Informational Messages When you turn on the system, POST displays messages that provide information about the system. If a failure occurs, POST emits beep codes that indicate errors in hardware, software, or firmware. If POST can display a message on the video display screen, it causes the speaker to beep twice as the message appears. POST Codes and Countdown Codes The BIOS indicates the current testing phase during POST after the video adapter has been successfully initialized by outputting a 2-digit hex code to I/O location 80h. If a port-80h ISA POST board is installed, it displays the 2-digit code on a pair of hex display LEDs. Hex codes and their meanings are listed in Table 34. Table 34: Port-80h Codes and Beep Codes Port-80 Codes Beep Codes 02 Verify Real Mode 04 Get processor type 06 Initialize system hardware 08 Initialize chipset registers with initial POST values 09 Set in POST flag 0A Initialize processor registers 0B Enable processor cache 0C Initialize caches to initial POST values 0E Initialize I/O 0F Initialize the local bus IDE 10 Initialize Power Management 11 Load alternate registers with initial POST values new 12 Restore processor control word during warm boot 14 Initialize keyboard controller 16 1-2-2-3 BIOS ROM checksum 18 8254 timer initialization 1A 8237 DMA controller initialization 1C Reset Programmable Interrupt Controller 20 1-3-1-1 Test DRAM refresh 22 1-3-1-3 Test 8742 Keyboard Controller 24 28 2A 170 Error Descriptions Set ES segment register to 4GB 1-3-3-1 Autosize DRAM Clear 512K base RAM Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 171 Wednesday, September 2, 1998 9:23 AM Table 34: Port-80h Codes and Beep Codes (Continued) Port-80 Codes Beep Codes Error Descriptions 2C 1-3-4-1 RAM failure on address line xxxx* 2E 1-3-4-3 RAM failure on data bits xxxx* of low byte of memory bus 30 1-4-1-1 RAM failure on data bits xxxx* of high byte of memory bus 32 Test processor bus-clock frequency 34 Test CMOS 35 RAM Initialize alternate chipset registers 36 Warm start shut down 37 Reinitialize the chipset (MB only) 38 Shadow system BIOS ROM 39 Reinitialize the cache (MB only) 3A Autosize cache 3C Configure advanced chipset registers 3D Load alternate registers with CMOS values new 40 Set Initial processor speed new 42 Initialize interrupt vectors 44 46 Initialize BIOS interrupts 2-1-2-3 47 Check ROM copyright notice Initialize manager for PCI Option ROMs 48 Check video configuration against CMOS 49 Initialize PCI bus and devices 4A Initialize all video adapters in system 4B Display QuietBoot screen 4C Shadow video BIOS ROM 4E Display copyright notice 50 Display processor type and speed 51 Initialize EISA board 52 Test keyboard 54 Set key click if enabled 56 58 5A Enable keyboard 2-2-3-1 Test for unexpected interrupts Display prompt “Press F2 to enter SETUP” 5C Test RAM between 512 and 640k 60 Test extended memory 62 Test extended memory address lines 64 Jump to UserPatch1 66 Configure advanced cache registers 68 Enable external and processor caches 6A Display external cache size 6C Display shadow message 6E Display non-disposable segments Error and Informational Messages 171 3424.boo Page 172 Wednesday, September 2, 1998 9:23 AM Table 34: Port-80h Codes and Beep Codes (Continued) Port-80 Codes Beep Codes 70 Display error messages 72 Check for configuration errors 74 Test real-time clock 76 Check for keyboard errors 7A Test for key lock on 7C Set up hardware interrupt vectors 7E Test coprocessor if present 80 Detect and install external RS232 ports 82 Detect and install external parallel ports 85 Initialize PC-compatible PnP ISA devices 86 Re-initialize on board I/O ports 88 Initialize BIOS Data Area 8A Initialize Extended BIOS Data Area 8C Initialize floppy controller 90 Initialize hard disk controller 91 Initialize local bus hard disk controller 92 Jump to UserPatch2 93 Build MPTABLE for multi-processor boards 94 Disable A20 address line 95 Install CD-ROM for boot 96 98 Clear huge ES segment register 1-2 Search for option ROMs. One long, two short beeps on checksum failure 9A Shadow option ROMs 9C Set up Power Management 9E Enable hardware interrupts A0 Set time of day A2 Check key lock A4 Initialize typematic rate A8 Erase F2 prompt AA Scan for F2 key stroke AC Enter SETUP AE Clear in-POST flag B0 Check for errors B2 B4 172 Error Descriptions POST done – prepare to boot Operating System 1 One short beep before boot B5 Display MultiBoot menu B6 Check password (optional) B8 Clear global descriptor table BC Clear parity checkers BE Clear screen (optional) Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 173 Wednesday, September 2, 1998 9:23 AM Table 34: Port-80h Codes and Beep Codes (Continued) Port-80 Codes Beep Codes Error Descriptions BF Check virus and backup reminders C0 Try to boot with INT 19 D0 Interrupt handler error D4 Pending interrupt error D6 Initialize option ROM error D8 Shutdown error DA Extended Block Move DC Shutdown 10 error POST Error Codes and Messages The following error codes and messages are representative of various conditions BIOS identifies. The exact strings and error numbers may be different from those listed in Table 35. Table 35: POST Error Codes Code Message 0162 BIOS unable to apply BIOS update to processor 1 0163 BIOS unable to apply BIOS update to processor 2 0164 BIOS does not support current stepping for processor 1 0165 BIOS does not support current stepping for processor 2 0200 Failure Fixed Disk 0210 Stuck Key 0211 Keyboard error 0212 Keyboard Controller Failed 0213 Keyboard locked - Unlock key switch 0220 Monitor type does not match CMOS - Run SETUP 0230 System RAM Failed at offset 0231 Shadow RAM Failed at offset 0232 Extended RAM Failed at offset 0250 System battery is dead - Replace and run SETUP 0251 System CMOS checksum bad - Default configuration used 0260 System timer error 0270 Real-time clock error 0297 ECC Memory error in base (extended) memory test in Bank xx 02B2 Incorrect Drive A type - run SETUP 02B3 Incorrect Drive B type - run SETUP 02D0 System cache error - Cache disabled 02F5 DMA Test Failed Error and Informational Messages 173 3424.boo Page 174 Wednesday, September 2, 1998 9:23 AM Table 35: POST Error Codes (Continued) Code 174 Message 02F6 Software NMI Failed 0401 Invalid System Configuration Data - run configuration utility None System Configuration Data Read Error 0403 Resource Conflict 0404 Resource Conflict 0405 Expansion ROM not initialized 0406 Warning: IRQ not configured 0504 Resource Conflict 0505 Expansion ROM not initialized 0506 Warning: IRQ not configured 0601 Device configuration changed 0602 Configuration error - device disabled 8100 Processor 0 failed BIST 8101 Processor 1 failed BIST 8104 Processor 0 Internal Error (IERR) failure 8105 Processor 1 Internal Error (IERR) failure 8106 Processor 0 Thermal Trip failure 8107 Processor 1 Thermal Trip failure 8108 Watchdog Timer failed on last boot, BSP switched 810A Processor 1 failed initialization on last boot 810B Processor 0 failed initialization on last boot 810C Processor 0 disabled, system in uniprocessor mode 810D Processor 1 disabled, system in uniprocessor mode 810E Processor 0 failed FRB Level 3 timer 810F Processor 1 failed FRB Level 3 timer 8110 Server Management Interface failed to function 8120 IOP subsystem is not functional 8150 NVRAM Cleared by Jumper 8151 NVRAM Checksum Error, NVRAM cleared 8152 NVRAM Data Invalid, NVRAM cleared Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 175 Wednesday, September 2, 1998 9:23 AM Appendix A: Reference Data Contents Specifications....................................................... 176 System I/O Addresses ......................................... 178 Memory Map....................................................... 181 Interrupts.............................................................. 182 Video Modes........................................................ 183 DMA Usage......................................................... 187 3424.boo Page 176 Wednesday, September 2, 1998 9:23 AM Specifications System Specifications The following specifications are for the standard configuration; your system may contain optional equipment. All specifications are subject to change. 176 Summary The system supports up to four Pentium II Xeon processors running at 400 or 450 MHz. These processors fit into the slot 2 connectors on the system board. The system also supports seven expansion slots, six LVD SCA SCSI drives, onboard narrow and onboard wide SCSI controller, and a full complement of I/O ports Dimensions 19.0”H x 12.25”W x 25.0”D, 85–100 lbs. Processor Intel Pentium II Xeon processor Processor speed 400 or 450 MHz Processor upgrade Slot 2 Cache subsystem 512 KB, 1 MB, or 2 MB level-2 ECC cache RAM 256-MB standard, 4-GB maximum BIOS Intel IDE interfaces One, supporting two IDE devices Diskette drive 1.44-MB 3.5-inch I/O Ports Two serial, one parallel, video, mouse, USB, and keyboard Mouse/Keyboard Yes ISA/PCI Expansion Slots Seven PCI/ One ISA (One of the PCI slots and the ISA slot are shared) Certification FCC Class A, TUV, CE, CSA, and UL approved Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 177 Wednesday, September 2, 1998 9:23 AM Environmental Specifications The following specifications identify maximum environmental characteristics. At no time should the server run under conditions which violate these specifications. Table 36: Environmental Specifications Variable Requirements Temperature Maximum rate of change = 10°C per hour Nonoperating –40° to 70 °C (–55° to 150 °F) Operating 10° to 35 °C (41° to 95 °F); derated 0.5 °C for every 1000 ft (305 m) Altitude 10,000 ft max Humidity Nonoperating 95% relative (noncondensing) @ 30°C (86°F) Operating wet bulb Not to exceed 33 °C (91.4 °F) (with diskette drive or hard disk drive) Shock Operating 2.0 g, 11 msec, 1/2 sine Packaged Operational after 30-inch free fall (cosmetic damage might occur) Acoustic noise < 50 dBA w/ two power supplies at 28 °C +/- 2 °C < 55 dBA w/ three power supplies at 28 °C +/- 2 °C Electrostatic discharge (ESD) Tested to 20 kilovolts (kV) per Intel environmental test specifications; no component damage AC Input Power 100-120 V∼ 100-120 V∼, 7.6 A, 50/60 Hz 200-240 V∼ 200-240 V∼, 3.8 A, 50/60 Hz Specifications 177 3424.boo Page 178 Wednesday, September 2, 1998 9:23 AM System I/O Addresses Table 37 shows the location in I/O space of all directly I/O-accessible registers. Table 37: System I/O Addresses Address Resource Device Notes 0000h - 000Fh DMA Controller 1 PIIX4E 0010h - 001Fh DMA Controller 1 PIIX4E 0020h - 0021h Interrupt Controller 1 PIIX4E Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h 002Ch - 002Dh Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h 002Eh - 002Fh Super I/O Index and Data Ports 0030h - 0031h Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h Interrupt Controller 1 PIIX4E Aliased from 0020h - 0021h Programmable Timers PIIX4E Programmable Timers PIIX4E Aliased from 0000h - 000Fh 0022h - 0023h 0024h - 0025h 0026h - 0027h 0028h - 0029h 002Ah - 002Bh 0032h - 0033h 0034h - 0035h 0036h - 0037h 0038h - 0039h 003Ah - 003Bh 003Ch - 003Dh 003Eh - 003Fh 0040h - 0043h 0044h - 004Fh 0050h - 0053h Aliased from 0040h - 0043h 0054h - 005Fh 178 0060h, 0064h Keyboard Controller 0061h NMI Status & Control Register PIIX4E 0063h NMI Status & Control Register PIIX4E Aliased 0065h NMI Status & Control Register PIIX4E Aliased 0067h NMI Status & Control Register PIIX4E Aliased Maintaining and Troubleshooting the Gateway ALR 9200 Server Keyboard chip select from 87307 3424.boo Page 179 Wednesday, September 2, 1998 9:23 AM Table 37: System I/O Addresses (Continued) Address Resource Device Notes 0070h NMI Mask (bit 7) & RTC Address (bits 6::0) PIIX4E 0072h NMI Mask (bit 7) & RTC Address (bits 6::0) PIIX4E Aliased from 0070h 0074h NMI Mask (bit 7) & RTC Address (bits 6::0) PIIX4E Aliased from 0070h 0076h NMI Mask (bit 7) & RTC Address (bits 6::0) PIIX4E Aliased from 0070h 0071h RTC Data PIIX4E 0073h RTC Data PIIX4E Aliased from 0071h 0075h RTC Data PIIX4E Aliased from 0071h Aliased from 0071h 0077h RTC Data PIIX4E 0080h - 008Fh DMA Low Page Register PIIX4E 0090h - 0091h DMA Low Page Register PIIX4E Aliased 0092h System Control Port A (PC-AT control Port) PIIX4E Not aliased in DMA range 0093h - 009Fh DMA Low Page Register PIIX4E Aliased 0094h Video Display Controller 00A0h - 00A1h Interrupt Controller 2 PIIX4E 00A4h - 00A15 Interrupt Controller 2 PIIX4E Aliased 00A8h - 00A19 Interrupt Controller 2 PIIX4E Aliased 00Ach - 00Adh Interrupt Controller 2 PIIX4E Aliased Aliased 00B0h - 00B1h Interrupt Controller 2 PIIX4E 00B2h Advanced Power Management Control PIIX4E 00B3h Advanced Power Management Status PIIX4E 00B4h - 00B5h Interrupt Controller 2 PIIX4E Aliased 00B8h - 00B9h Interrupt Controller 2 PIIX4E Aliased 00BCh - 00BDh Interrupt Controller 2 PIIX4E Aliased 00C0h - 00DFh DMA Controller 2 PIIX4E 00F0h Clear NPX error 00F8h - 00FFh x87 Numeric Coprocessor Resets IRQ13 0102h Video Display Controller 0170h - 0177h Secondary Fixed Disk Controller (IDE) PIIX4E 01F0h - 01F7h Primary Fixed Disk Controller (IDE) PIIX4E 0200h - 0207h Game I/O Port Not used Not used System I/O Addresses 179 3424.boo Page 180 Wednesday, September 2, 1998 9:23 AM Table 37: System I/O Addresses (Continued) 180 Address Resource 0220h - 022Fh Serial Port A 0238h - 023Fh Serial Port B 0278h - 027Fh Parallel Port 3 02E8h - 02Efh Serial Port B 02F8h - 02FFh Serial Port B 0338h - 033Fh Serial Port B 0370h - 0375h Secondary Diskette 0376h Secondary IDE 0377h Secondary IDE/Diskette 0378h - 037Fh Parallel Port 2 03B4h - 03Bah Monochrome Display Port 03BCh - 03BFh Parallel Port 1 (Primary) 03C0h - 03CFh Video Display Controller 03D4h - 03DAh Color Graphics Controller 03E8h - 03EFh Serial Port A 03F0h - 03F5h Diskette Controller 03F6h - 03F7h Primary IDE - Sec. Diskette 03F8h - 03FFh Serial Port A (Primary) 0400h - 043Fh DMA Controller 1, Extended Mode Registers 04D0h - 04D1h Interrupt Controllers 1 and 2 Control Register 0678h - 067Ah Parallel Port (ECP) 0778h - 077Ah Parallel Port (ECP) 07BCh - 07BEh Parallel Port (ECP) 0CA0 - CA3h BMC Registers 0CF8h PCI CONFIG_ADDRESS Register 0CF9h NBX Turbo and Reset control 0CFCh PCI CONFIG_DATA Register 46E8h Video Display Controller Maintaining and Troubleshooting the Gateway ALR 9200 Server Device Notes PIIX4E Located in 450NX PIIX4E Located in 450NX 3424.boo Page 181 Wednesday, September 2, 1998 9:23 AM Memory Map Table 38: Memory Map Address Range (hex) Amount Function 0 to 07FFFFh 640 KB DOS region, base system memory 0A0000h to 0BFFFFh 128 KB Video or SMM memory 0C0000h and 0DFFFFh 128 KB Expansion card BIOS and buffer area 0E0000h to 0FFFFFh 128 KB System BIOS 0E0000h to 0EFFFFh 2 MB Extended system BIOS FC000000h to FFFFFFFFh 64 MB PCI memory space Memory Map 181 3424.boo Page 182 Wednesday, September 2, 1998 9:23 AM Note: If you disable either IDE controller to free the interrupt for that controller, you must physically unplug the IDE cable from the system board. Simply disabling the drive by configuring the SSU option does not make the interrupt available. Interrupts Table 39 suggests a logical interrupt mapping of interrupt sources; it reflects a typical configuration, but you can change these interrupts. Use the information to determine how to program each interrupt. The actual interrupt map is defined using configuration registers in the PIIX4E and the I/O controller. I/O Redirection Registers in the I/O APIC are provided for each interrupt signal; the signals define hardware interrupt signal characteristics for APIC messages sent to local APIC(s). Table 39: Interrupts Interrupt I/O APIC Level Description INTR INT0 Processor interrupt NMI N/A NMI from PIC to processor IRQ1 INT1 Keyboard interrupt Cascade INT2 Interrupt signal from second 8259 in PIIX4E IRQ3 INT3 Serial port A or B interrupt from SIO device (you can configure either) IRQ4 INT4 Serial port A or B interrupt from SIO device (you can configure either) IRQ5 INT5 Parallel port II IRQ6 INT6 Diskette port IRQ7 INT7 Parallel port IRQ8_L INT8 RTC interrupt IRQ9 INT9 Signal control interrupt (SCI) used by ACPI-compliant operating system IRQ10 INT10 IRQ11 INT11 IRQ12 INT12 IRQ13 INT13 Co-processor interrupt IRQ14 INT14 Compatibility IDE interrupt from primary channel IDE devices 0 and 1 IRQ15 INT15 SMI_L 182 Mouse interrupt System management interrupt—general purpose indicator sourced by the PIIX4E and BMC through the PID to the processors Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 183 Wednesday, September 2, 1998 9:23 AM Video Modes The CL-GD5480 integrated video controller provides all standard IBM VGA modes. With 2 MB of SGRAM standard, the system supports special Cirrus Logic extended modes. Table 40 and Table 41 list the standard and extended modes that this implementation supports, including the number of colors and palette size (e.g., 16 colors out of 256 K colors), resolution, pixel frequency, and scan frequencies. Table 40: Standard VGA Modes Mode Bits / in Hex Pixel Colors (#/ Palette Size) Resolution Pixel Freq. (MHz) Horiz. Freq. (kHz) Vert. Freq. (Hz) 0, 1 4 16/256K 2, 3 4 16/256K 360 X 400 14 31.5 70 720 X 400 28 31.5 4, 5 4 4/256K 70 320 X 200 12.5 31.5 70 6 4 2/256K 640 X 200 25 31.5 70 7 4 Mono 720 X 400 28 31.5 70 D 4 16/256K 320 X 200 12.5 31.5 70 E 4 16/256K 640 X 200 25 31.5 70 F 4 Mono 640 X 350 25 31.5 70 10 4 16/256K 640 X 350 25 31.5 70 11 4 2/256K 640 X 480 25 31.5 60 12 4 16/256K 640 X 480 25 31.5 60 12+ 4 16/256K 640 X 480 31.5 37.5 75 13 8 256/256K 320 X 200 12.5 31.5 70 Table 41: Extended VGA Modes Mode in Hex Bits / Pixel Colors (#/ Palette Size) Horiz. Freq. (kHz) Vert. Freq. (Hz) Memory Resolution Pixel Freq. (MHz) 58, 6A 8 16/256K 58, 6A 8 16/256K 800 X 600 36 35.2 56 1MB 800 X 600 40 37.8 60 58, 6A 8 1MB 16/256K 800 X 600 50 48.1 72 58, 6A 1MB 8 16/256K 800 X 600 49.5 46.9 75 1MB 5C 8 256/256K 800 X 600 36 35.2 56 1MB 5C 8 256/256K 800 X 600 40 37.9 60 1MB 5C 8 256/256K 800 X 600 50 48.1 72 1MB 5C 8 256/256K 800 X 600 49.5 46.9 75 1MB 5C 8 256/256K 800 X 600 56.25 53.7 85 1MB Video Modes 183 3424.boo Page 184 Wednesday, September 2, 1998 9:23 AM Table 41: Extended VGA Modes (Continued) 184 Mode in Hex Bits / Pixel Colors (#/ Palette Size) 5C 8 256/256K 800 X 600 68.2 63.6 100 1MB 5D 8 16/256K (interlaced) 1024 X 768 44.9 35.5 43 1MB 5D 8 16/256K 1024 X 768 65 48.3 60 1MB 5D 8 16/256K 1024 X 768 75 56 70 1MB 5D 8 16/256K 1024 X 768 78.7 60 75 1MB 5E 8 256/256K 640 X 400 25 31.5 70 1MB 5F 8 256/256K 640 X 480 25 31.5 60 1MB 5F 8 256/256K 640 X 480 31.5 37.9 72 1MB 5F 8 256/256K 640 X 480 31.5 37.5 75 1MB 5F 8 256/256K 640 X 480 36 43.3 85 1MB 5F 8 256/256K 640 X 480 43.2 50.9 100 1MB 60 8 256/256K (interlaced) 1024 X 768 44.9 35.5 43 1MB 60 8 256/256K 1024 X 768 65 48.3 60 1MB 60 8 256/256K 1024 X 768 75 56 70 1MB 60 8 256/256K 1024 X 768 78.7 60 75 1MB 60 8 256/256K 1024 X 768 94.5 68.3 85 1MB 60 8 256/256K 1024 X 768 113.3 81.4 100 1MB 64 16 64K 640 X 480 25 31.5 60 1MB 64 16 64K 640 X 480 31.5 37.9 72 1MB 64 16 64K 640 X 480 31.5 37.5 75 1MB 64 16 64K 640 X 480 36 43.3 85 1MB 64 16 64K 640 X 480 43.2 50.9 100 1MB 65 16 64K 800 X 600 36 35.2 56 1MB 65 16 64K 800 X 600 40 37.8 60 1MB 65 16 64K 800 X 600 50 48.1 72 1MB 65 16 64K 800 X 600 49.5 46.9 75 1MB 65 16 64K 800 X 600 56.25 53.7 85 1MB 65 16 64K 800 X 600 68.2 63.6 100 1MB 66 16 32K 640 X 480 25 31.5 60 1MB 66 16 32K 640 X 480 31.5 37.9 72 1MB 66 16 32K 640 X 480 31.5 37.5 75 1MB 66 16 32K 640 X 480 36 43.3 85 1MB 66 16 32K 640 X 480 43.2 50.9 100 1MB 67 16 32K 800 X 600 36 35.2 56 1MB 67 16 32K 800 X 600 40 37.8 60 1MB 67 16 32K 800 X 600 50 48.1 72 1MB 67 16 32K 800 X 600 49.5 46.9 75 1MB Maintaining and Troubleshooting the Gateway ALR 9200 Server Resolution Pixel Freq. (MHz) Horiz. Freq. (kHz) Vert. Freq. (Hz) Memory 3424.boo Page 185 Wednesday, September 2, 1998 9:23 AM Table 41: Extended VGA Modes (Continued) Mode in Hex Bits / Pixel Colors (#/ Palette Size) Horiz. Freq. (kHz) Vert. Freq. (Hz) Memory Resolution Pixel Freq. (MHz) 67 16 32K 67 16 32K 800 X 600 56.25 53.7 85 1MB 800 X 600 68.2 63.6 100 68 16 1MB 32K (interlaced) 1024 X 768 44.9 35.5 43 2MB 68 68 16 32K 1024 X 768 65 48.3 60 2MB 16 32K 1024 X 768 75 56 70 2MB 68 16 32K 1024 X 768 78.7 60 75 2MB 68 16 32K 1024 X 768 94.5 68.3 85 2MB 68 16 32K 1024 X 768 113.3 81.4 100 2MB 6C 8 16/256K (interlaced) 1280 X 1024 75 48 43 1MB 6D 8 256/256K (interlaced) 1280 X 1024 75 48 43 2MB 6D 8 256/256K 1280 X 1024 108 65 60 2MB 6D 8 256/256K 1280 X 1024 135 80 75 2MB 6D 8 256/256K 1280 X 1024 157.5 91 85 2MB 6E 16 32K 1152 X 864 94.5 63.9 70 2MB 6E 16 32K 1152 X 864 108 67.5 75 2MB 6E 16 32K 1152 X 864 121.5 76.7 85 2MB 6E 16 32K 1152 X 864 143.5 91.5 100 2MB 71 24 16M 640 X 480 25 31.5 60 1MB 71 24 16M 640 X 480 31.5 37.9 72 1MB 71 24 16M 640 X 480 31.5 37.5 75 1MB 71 24 16M 640 X 480 36 43.3 85 1MB 71 24 16M 640 X 480 43.2 50.9 100 1MB 74 16 64K (interlaced) 1024 X 768 44.9 35.5 43 2MB 74 16 64K 1024 X 768 65 48.3 60 2MB 74 16 64K 1024 X 768 75 56 70 2MB 74 16 64K 1024 X 768 78.7 60 75 2MB 74 16 64K 1024 X 768 94.5 68.3 85 2MB 74 16 64K 1024 X 768 113.3 81.4 100 2MB 78 16 32K 800 X 600 36 35.2 56 1MB 78 24 16M 800 X 600 40 37.8 60 2MB 78 24 16M 800 X 600 50 48.1 72 2MB 78 24 16M 800 X 600 49.5 46.9 75 2MB 78 24 16M 800 X 600 56.25 53.7 85 2MB 78 24 16M 800 X 600 68.2 63.6 100 2MB 7B 8 256/256K (interlaced) 1600 X 1200 135 62.5 48 2MB Video Modes 185 3424.boo Page 186 Wednesday, September 2, 1998 9:23 AM Table 41: Extended VGA Modes (Continued) 186 Mode in Hex Bits / Pixel Colors (#/ Palette Size) Pixel Freq. (MHz) Horiz. Freq. (kHz) Vert. Freq. (Hz) Memory Resolution 7B 8 256/256K 1600 X 1200 162 75 60 2MB 7C 8 256/256K 1152 X 864 94.5 63.9 70 1MB 7C 8 256/256K 1152 X 864 108 67.5 75 1MB 7C 8 256/256K 1152 X 864 121.5 76.7 85 1MB 7C 8 256/256K 1152 X 864 143.5 91.5 100 1MB 7D 16 64K 1152 X 864 94.5 63.9 70 2MB 7D 16 64K 1152 X 864 108 67.5 75 2MB 7D 16 64K 1152 X 864 121.5 76.7 85 2MB 7D 16 64K 1152 X 864 143.5 91.5 100 2MB Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 187 Wednesday, September 2, 1998 9:23 AM DMA Usage The following table lists the direct memory access (DMA) channels that the system typically uses and which ones are available for use by add-in devices. Table 42: DMA Usage DMA Resource 0 Cascade 1 Available 2 Floppy Controller 3 Available 4 Redirect Cascade 5 Available 6 Available 7 Available DMA Usage 187 3424.boo Page 188 Wednesday, September 2, 1998 9:23 AM 188 Maintaining and Troubleshooting the Gateway ALR 9200 Server 3424.boo Page 189 Wednesday, September 2, 1998 9:23 AM Appendix B: Regulatory Compliance Statements Contents Electromagnetic Compatibility........................... 190 FCC Notice .......................................................... 191 Industry Canada Notice....................................... 192 CE Notice............................................................. 192 VCCI Notice ........................................................ 193 Australia/New Zealand Notice............................ 193 Declaration of the Manufacturer or Importer ..... 194 Safety Compliance .............................................. 194 3424.boo Page 190 Wednesday, September 2, 1998 9:23 AM Electromagnetic Compatibility Table 43 lists the electromagnetic compatibility (EMC) standards to which the server conforms. The following sections provide notices for several nations and regions. Table 43: EMC Standards Nation or Region Standards 190 USA: FCC CFR 47 Part 15, Class A Canada: IC ICES-003 Class A Europe: EN55022, Class A EN50082-1 IEC 801-2 ESD Susceptibility IEC 801-3 Radiated Immunity IEC 801-4 Electrical Fast Transient EN61000-3-2 Limit for Harmonic Current Emissions International: CISPR 22, Class A Japan: VCCI Class A (CISPR 22 A limit) Maintaining and Troubleshooting the Gateway ALR 9200 3424.boo Page 191 Wednesday, September 2, 1998 9:23 AM FCC Notice This device has been tested and found to comply with the limits for a Class A digital device, pursuant to FCC CFR 47 Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio and television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • Reorient or relocate the receiving antenna. • • Consult the dealer or an experienced radio/TV technician for help. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. American Users Caution! The Federal Communications Commission warns users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Use shielded I/O cables when operating this equipment. FCC Notice 191 3424.boo Page 192 Wednesday, September 2, 1998 9:23 AM Industry Canada Notice Canadian Users: This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of Industry Canada. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de Classe A prescrites dans le règlement sur le brouillage radioélectrique édicté par Industrie Canada. Attention! Couper le courant avant l’entretien. CE Notice European Users: This Information Technology Equipment has been tested and found to comply with the following European directives: [i] EMC Directive 89/336/EEC amending Directives 92/31/EEC & 93/68/ EEC as per: - EN 50081-1:1992 according to EN 55022:1995 Class A EN 61000-3-2:1995 or EN 60555-2:1986 EN 61000-3-3: 1995 - EN50082-1:1992 according to EN 61000-4-2:1995 or IEC 801-2:1984 ENV 50140:1994 or IEC 801-3:1984 EN 61000-4-4:1988 or IEC 801-4:1998 [ii] Low Voltage Directive (Safety) 73/23/EEC as per EN 60950 192 Maintaining and Troubleshooting the Gateway ALR 9200 3424.boo Page 193 Wednesday, September 2, 1998 9:23 AM VCCI Notice This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective action. Japanese Users: Australia/New Zealand Notice This device has been tested and found to comply with the limits for a Class A digital device, pursuant to the Australian/New Zealand standard AS/NZS 3548 set out by the Spectrum Management Agency. Australian and New Zealand Users: VCCI Notice 193 3424.boo Page 194 Wednesday, September 2, 1998 9:23 AM Declaration of the Manufacturer or Importer We hereby certify that this product is in compliance with European Union EMC Directive 89/336/EEC, using standards EN55022 (Class A) and EN50082-1 and Low Voltage Directive 73/23/EEC, Standard EN60950. Safety Compliance Table 44 lists the electromagnetic compatibility (EMC) standards to which the server conforms. The following sections provide notices for several nations and regions. Table 44: Safety Compliance Standards Nation or Region Standards USA: UL 1950 - CSA 950-95, 3rd Edition Canada: UL certified to CSA 950-95 for Canada (product bears the single UL mark for U.S. and Canada) Europe: German GS Mark - ERG to EN60950 2nd Edition, with amendments International: NEMKO to IEC950 2nd Edition + Amd 1-4 NEMKO - EN60 950 2nd Edition + Amd 1-4 NEMKO - EMKO-TSE (74-SEC) 207/94 Australian / New Zealand AS/NZ 3548, Class A limits (CISPR 22) AS/NZ 3260 (IEC 950 including national AU deviations) Caution! This system may include more than one power supply. You must disconnect all power supplies before servicing. 194 Maintaining and Troubleshooting the Gateway ALR 9200 3424.boo Page 195 Wednesday, September 2, 1998 9:23 AM Index Numerics 3.5-inch drive diskette, installing 47 diskette, removing 45 diskette, replacing 47 SCSI, hot-swapping 56 32 Bit I/O, Setup field 86 4-way interleaving, memory 23 5.25-inch drive installing 4, 49 removing 52 A about this guide viii access cover installing 8 removing 3 replacing 8 Access Modes, EMP Console 134 accessing Setup 82 adapter card installing 63 removing 64 add-in board installing 63 removing 64 adding an ISA board in the SSU 114 Address Bit Permuting, Setup field 91 addresses, I/O 178 addressing memory 24 Administrator Password is, Setup field 92 administrator password, access 27 Advanced Chipset Control Setup field 88 Setup menu 91 advanced menu, Setup menu 87 Assert NMI on AERR, Setup field 94 Assert NMI on BERR, Setup field 94 Assert NMI on PERR, Setup field 94 Assert NMI on SERR, Setup field 94 B Base I/O Address, Setup field diskette controller 90 floppy disk controller 90 parallel port 90 serial port A 89 serial port B 90 base memory 24 Base RAM Step, Setup field 91 basic input/output system see BIOS battery replacing 68 system 15 troubleshooting replacement 69 Baud Rate EMP Console 134 Setup field 95 beep codes flash update recovery 76 system 170 when there are none 165 bezel installing 8 opening 4 replacing 8 BIOS 32 Bit I/O field 86 accessing Setup 82 Address Bit Permuting field 91 Administrator Password is field 92 Advanced Chipset Control field 88 advanced chipset control menu 91 advanced menu 87 Assert NMI on AERR field 94 Assert NMI on BERR 94 Index 195 3424.boo Page 196 Wednesday, September 2, 1998 9:23 AM Assert NMI on PERR field 94 Assert NMI on SERR field 94 Base I/O Address field, diskette controller 90 Base I/O Address field, floppy disk controller 90 Base I/O Address field, parallel port 90 Base I/O Address field, serial port A 89 Base I/O Address field, serial port B 90 Base RAM Step 91 Baud Rate field 95 Boot Device Priority field 95 boot device priority menu 96 boot menu 95 changing the language 101 Clear Event Logging field 94 COM Port Address field 94 Console Redirection field 93 console redirection menu 94 creating upgrade diskette 99 Cylinders field 86 diskette controller field 90 diskette write protect field 93 DMA Channel field, parallel port 90 Enable Master field, PCI device, embedded SCSI 88 Enable Master field, PCI devices 89 Enabled Host Bus Error field 94 Exit Discarding Changes field 97 exit menu 97 Exit Saving Changes field 97 Extended RAM Step field 91 Fixed Disk Boot Sector field 92 Floppy Check field 95 Floppy disk controller field 90 floppy disk drive A 85 floppy disk drive B 85 196 Maintaining and Troubleshooting the Gateway ALR 9200 Server Floppy Write Protect field 93 Flow Control field 95 Hard Disk Pre-delay field 85 Hard Drive field 95 hard drive menu 96 Heads field 86 I/O Device Configuration field 87 I/O device configuration menu 89 Interrupt field, parallel port 90 Interrupt field, serial port A 89 Interrupt field, serial port B 90 introduction 80 IRQ # field 94 ISA Expansion Aliasing field 91 Key Click field 87 key commands 84 Keyboard auto-repeat delay field 87 Keyboard auto-repeat rate field 87 Keyboard Features field 85 keyboard features menu 87 L2 Cache field 91 Language field 85 Large Disk Access Mode field 88 Latency Timer field, PCI device, embedded SCSI 88 Latency Timer field, PCI devices 89 LBA Mode Control field 86 Legacy Diskette A 85 Legacy Diskette B 85 Load Custom Defaults field 97 Load Setup Defaults field 97 main menu 85 Maximum Capacity field 86 Maximum Number of I2O Drives field 95 memory 15 Memory Scrubbing field 91 menus 83 Message Timeout Multiplier field 95 3424.boo Page 197 Wednesday, September 2, 1998 9:23 AM Mode field, parallel port 90 Mode field, serial port B 90 Multi-boot Support field 95 Multi-Sector Transfers field 86 Num Lock field 87 obtaining the upgrade utility 98 Option ROM Scan field, PCI device, embedded SCSI 88 Option ROM Scan field, PCI devices 89 Parallel Port field 90 Password on Boot field 92 Pause Before Boot field 88 PCI Configuration field 87 PCI configuration menu 88 PCI Device, Embedded SCSI field 88 PCI device, embedded SCSI menu 88 PCI Devices field 89 PCI devices menu 89 Plug and Play OS field 87 preparing for an upgrade 98 Primary Master field 85 primary master menu 86 Primary Slave field 85 primary slave menu 86 Processor Retest field 93 PS/2 Mouse field 90 Read Prefetch for PXB0A field 91 Read Prefetch for PXB0B field 91 record settings 81, 98 recovering 101 Removable Devices field 95 Reset Configuration Data field 87 Restreaming Buffer field 91 Sectors field 86 Secure Mode Boot field 93 Secure Mode Hot Key (Ctrl-Alt- ) field 93 Secure Mode Timer field 92 security menu 92 Serial Port A field 89 Serial Port B field 89 Server Management Mode field 94 server menu 93 Set Administrator Password field 92 Set User Password field 92 special display items 84 starting Setup 82 System Backup Reminder field 92 System Date field 85 System Event Logging field 94 System Management field 93 system management menu 94 System Time field 85 Transfer Mode field 86 Type field 86 Ultra DMA field 86 upgrading 98, 100 Use Multiprocessor Specification field 87 User Password is field 92 using 81 Video Blanking field 93 Virus Check Reminder field 92 when to use it 81 BMC, server management 16 boot diskette check field 95 sequence, setting 29 Setup menu 95 Boot Device Priority Setup field 95 Setup menu 96 bootable diskette, creating 99 bus ISA 10 PCI 10 USB 20 button, disabling power and reset buttons 28 Index 197 3424.boo Page 198 Wednesday, September 2, 1998 9:23 AM C cabling drives 48 IDE drives 49 SCSI drives 49 cache first level 21 second level, power support 20 second-level 21 carrier, mounting a SCSI drive 55 CD-ROM bootable drive is not detected 169 drive activity light does not light 168 central processing unit see also processor see CPU certifications 194 CFG files, using in the FRU and SDR load utility 149 changing administrator password in the SSU 116 boot priority in the SSU 115 user password in the SSU 116 characters are distorted or incorrect onscreen 166 chassis closing 7 intrusion monitoring 16, 18 intrusion switch 26 opening 3 checklist, troubleshooting 158 Clear CMOS jumper 13, 74 Clear Event Logging, Setup field 94 clearing administrator password in the SSU 116 user password in the SSU 116 Client Configuration, EMP Console 132 closing chassis 7 electronics bay 7 198 Maintaining and Troubleshooting the Gateway ALR 9200 Server subchassis 7 system 7 CMOS memory 13 setting defaults 74 COM Port Address EMP Console 134 Setup field 94 command line format, FRU and SDR load utility 146 parsing, FRU and SDR load utility 146 command state, EMP Console 130 complimentary metal-oxide semiconductor see CMOS comuter virus notice 155 configuration memory 25 power supply modules 65 through SSU 105 verifying 158 connect to remote server, EMP Console 137 connector auxiliary power 22 back panel I/O 18 diskette drive 13 drives 12 expansion slots 15 external IPMB 18 F16 expansion 18 floppy drive 13 front panel 15 hard drive input 14 ICMB 18 IDE 13 internal USB 15 keyboard 19 main power 21 memory module 16 mouse 19 3424.boo Page 199 Wednesday, September 2, 1998 9:23 AM narrow SCSI 12 parallel port 19 processor slots 21 SCSI, narrow 12 SCSI, wide 12 serial ports 19 SMBus 18 SMM 18 speaker 14 system board 10 USB 20 video 18 VRMs 20 wake-on-LAN technology 14 wide SCSI 12 Console Redirection EMP Console menu 134 Setup field 93 Setup menu 94 Console Type, EMP Console 134 controlled access, SSU 28 controller drives 12 graphics 10 SCSI narrow 10 SCSI wide 10 video 10 controlling the server through the EMP Console 136 conventions used in this guide ix cooling installing fan for correct airflow 62 record airflow when removing fan 59 countdown codes 170 CPU first-level cache 21 heatsink 32, 36 installing 34, 38 installing second 36 MMX technology 21 multiprocessor capability 21 power support 20 removing 33 removing termination card 36 replacing 32 second-level cache 21 see also processor slots 21 supported 10 customizing the SSU 109 Cylinders, Setup field 86 D defining an ISA board in the SSU 113 diagnostic testing, preparing the system 162 DIMM banks 23 installation sequence 24 installing 43 removing 41 supported 10, 23 Direct Connect Configuration, EMP Console 133 direct memory access see DMA diskette activity light does not light 167 connector 13 controller field, Setup 90 creating BIOS upgrade diskette 99 creating bootable 99 diskette check Setup field 95 installing 47 removing 45 replacing 47 write protect monitoring 17 write protect, Setup field 93 write protection summary 28 DMA Channel, Setup field, parallel port 90 DMA usage 187 document conventions ix DRAM, memory type 10 Index 199 3424.boo Page 200 Wednesday, September 2, 1998 9:23 AM drive 5.25-inch, installing 4 cabling considerations 48 CD-ROM activity light does not light 168 controllers and connectors 12 fans, high-power SCSI hard drives 57 floppy drive A field 85 floppy drive B field 85 hard disk activity light does not light 168 hard drive input LED connector 14 heatsinks on high-power SCSI hard drives 54 IDE, cabling 49 installing a 5.25-inch drive 49 installing the diskette drive 47 removing a 5.25-inch drive 52 removing the diskette drive 45 replacing the diskette drive 47 SCSI cabling 49 drive error LEDs 56 hot-swapping 56 mounting in carrier 55 drivers, video, installing 77 dual in-line memory module see DIMM dynamic random access memory see DRAM E ECC, memory type 10 editing resources in the SSU 115 EDO, memory type 10 electromagnetic compatibility see EMC electromagnetic interference see EMI electronics bay closing 7 defined 5 opening 5 200 Maintaining and Troubleshooting the Gateway ALR 9200 Server EMC compatibility 190 compliance with standards 194 emergency management port see EMP EMI shield, removing 50 EMP Console Baud Rate 134 Client Configuration 132 COM Port Address 134 command state 130 connect to remote server 137 console redirection menu 134 Console Type 134 Direct Connect Configuration 133 EMP Access Modes 134 EMP Direct Connect/Modem Mode 134 EMP Password 133 EMP Restricted Mode Access 134 Flow Control 134 FRU Viewer 144 FRU Viewer options 144 how it works 130 introduction 129 main menu 136 main window 134 management plug-ins 141 Modem Configuration 133 phonebook 140 power on/off remote server 138 redirect state 131 requirements 132 reset remote server 139 SDR Viewer 143 SDR Viewer options 143 SEL Viewer 141 SEL Viewer options 142 Server Configuration 133 server control operations 136 setting up the server 133 status bar 135 3424.boo Page 201 Wednesday, September 2, 1998 9:23 AM system management menu 133 toolbar 135 EMP Direct Connect/Modem Mode, EMP Console 134 EMP Restricted Mode Access, EMP Console 134 Enable Master Setup field, PCI device, embedded SCSI 88 Setup field, PCI devices 89 Enabled Host Bus Error, Setup field 94 environmental specifications 177 error codes 173 fan failure 16 memory 23 messages 170, 173 overtemperature 16 overvoltage 16 single-bit memory errors 40 error correcting code see ECC ESD see static electricity Exit Discarding Changes, Setup field 97 Exit Saving Changes, Setup field 97 exit, Setup menu 97 exiting FRU and SDR load utility 150 SSU 124 expansion card adding an ISA card in the SSU 114 defining an ISA card in the SSU 113 installing 63 removing 64 removing an ISA card in the SSU 114 testing a video controller 165 expansion slot connectors 15 ISA 15 PCI 16 PCI-A 16 PCI-B 16 shared 16 extended data output see EDO extended memory 24 Extended RAM Step, Setup field 91 extended VGA modes supported 183 external IPMB connector 18 F F16 expansion connector 18 fan failure monitoring 16 installing for high-power SCSI drives 57 installing system fan 62 installing, high-power drives 57 installing, power supply bay 57 removing a system fan 59 removing fan assembly 60 removing foam covers 60 speed monitoring 18 fault resilient boot see FRB features software security 28 system board 10 field replaceable unit see FRU Firmware Update utility running 151 using 151 first-level cache 21 Fixed Disk Boot Sector, Setup field 92 flash BIOS beep codes for recovery 76 memory 15 recovering 101 recovery if failed 75 upgrading 98, 100 Floppy check, Setup field 95 Floppy disk controller, Setup field 90 Index 201 3424.boo Page 202 Wednesday, September 2, 1998 9:23 AM floppy drive, connector 13 Floppy Write Protect, Setup field 93 Flow Control EMP Console 134 Setup field 95 foam covers, removing 60 format command line, FRU and SDR load utility 146 conventions ix four-way interleaving, memory 23 FRB, system management control 17 front bezel installing 8 lock/unlock 17 opening 4 replacing 8 front panel connector 15 FRU and SDR load utility 145 cleaning up and exiting 150 command line format 146 displaying usage data 147 parsing the command line 146 running 146 using CFG files 149 what you need to do 145 when to run 145 FRU Manager Add-in, SSU 122 FRU Viewer EMP Console 144 options 144 FUU see Firmware Update utility G graphics, controller 10 guidelines, troubleshooting 158 H Hard Disk Pre-delay, Setup field 85 Hard Drive input connector 14 Setup field 95 Setup menu 96 202 Maintaining and Troubleshooting the Gateway ALR 9200 Server hard drive fans for high-power drives 57 heatsinks on high-power drives 54 Heads, Setup field 86 heatsink high-power drives 54 processor 32, 36 high-power drives fans 57 heatsinks 54 hot-swapping power supply modules 65 SCSI drive 56 how the EMP Console works 130 how to run the FRU and SDR load utility 145 I I/O addresses, system 178 back panel connectors 18 ports 10 I/O Device Configuration Setup field 87 Setup menu 89 ICMB connector 18 IDE connectors 13 important safety instructions x industry standard architecture see ISA informational messages 170 input/output see I/O installing 5.25-inch drives 4, 49 access cover 8 adapter card 63 add-in board 63 bezel 8 DIMMs 43 DIMMs in sequence 24 diskette drive 47 expansion card 63 3424.boo Page 203 Wednesday, September 2, 1998 9:23 AM fan, high power drives 57 fan, power supply bay 57 floppy drive 47 front bezel 8 memory module 44 power supply module 67 processor 34, 38 second processor 36 side panel 8 system fan 62 video drivers 77 intelligent chassis management port see ICMB interperipheral management bus see IPMB Interrupt Setup field, parallel port 90 Setup field, serial port A 89 Setup field, serial port B 90 system 182 intrusion detection, monitoring 18 IPMB connector, external 18 IRQ #, Setup field 94 ISA adding a board in the SSU 114 bus 10 card support 15 defining a board in the SSU 113 expansion slot 15 memory holes 24 removing a board in the SSU 114 ISA Expansion Aliasing, Setup field 91 J jumper Clear CMOS 13, 74 function 72 location 72 Password Clear 14, 75 Recovery Boot 14, 75 set CMOS to system defaults 74 setting 73 system board 13 K Key Click, Setup field 87 key commands, Setup 84 keyboard booting without one 29 port 19 Keyboard auto-repeat delay, Setup field 87 Keyboard auto-repeat rate, Setup field 87 Keyboard Features Setup field 85 Setup menu 87 L L2 Cache, Setup field 91 LAN, wake-on-LAN connector 14 Language changing in the BIOS 101 Setup field 85 Large Disk Access Mode, Setup field 88 Latency Timer Setup field, PCI device 89 Setup field, PCI device, embedded SCSI 88 launching a task, SSU 111 LBA Mode Control, Setup field 86 LED hard drive input connector 14 monitoring for proper operation 163 SCSI drive error 56 Legacy Diskette A, Setup field 85 Legacy Diskette B, Setup field 85 light emiting diode see LED Load Custom Defaults, Setup field 97 Load Setup Defaults, Setup field 97 local area network see LAN locks software, security 26 Index 203 3424.boo Page 204 Wednesday, September 2, 1998 9:23 AM logical block addressing see LBA low voltage differential see LVD LVD, SCSI drives 10 M main menu EMP Console 136 Setup menu 85 main window, EMP Console 134 management plug-ins, EMP Console 141 Maximum Capacity, Setup field 86 Maximum Number of I2O Drives, Setup field 95 memory addressing 24 banks 23 base 24 CMOS 13 configuring 25 DRAM 10 error correction 23 extended 24 flash BIOS 15 four way interleaving 23 holes 24 installing DIMMs 43 installing memory module 44 map, system 181 module 23 module connector 16 removing DIMMs 41 removing the memory module 40 sequenced DIMM installation 24 supported 10 supported DIMMs 23 video, installed 10 Memory Scrubbing, Setup field 91 menus, Setup 83 Messaage Timeout Multiplier, Setup field 95 204 Maintaining and Troubleshooting the Gateway ALR 9200 Server Mode Setup field, parallel port 90 Setup field, serial port B 90 Modem configuration, EMP Console 133 modifying resources in the SSU 114 modules, power supply 65 monitor, supported 19 monitoring chassis intrusion 18 fan speeds 18 POST 163 temperature 18 voltages 18 mouse, port 19 Multiboot Options Add-in, SSU 115 Multi-boot Support, Setup field 95 Multi-Sector Transfers, Setup field 86 N narrow SCSI, connector 12 network problems, troubleshooting 168 NMI, generating 17 no characters appear onscreen 165 non-maskable interrupt see NMI notice, computer viruses 155 Num Lock, Setup field 87 O opening bezel 4 electronics bay 5 front bezel 4 subchassis 5 system 3 operating system, confirming load 164 Option ROM Scan Setup field, PCI device, embedded SCSI 88 Setup field, PCI devices 89 overtemperature, monitoring 16 overvoltage, monitoring 16 3424.boo Page 205 Wednesday, September 2, 1998 9:23 AM P Parallel Port connector 19 Setup field 90 password administrator changing in the SSU 116 clearing in the SSU 116 setting in the SSU 116 Administrator Password is Setup field 92 adminsitrator 28 both user and administrator passwords set 27 clearing by jumper 75 EMP Password 133 only user password set 27 Password on Boot Setup field 92 Set Administrator Password Setup, field 92 Set User Password Setup field 92 system access control 29 user changing in the SSU 116 clearing in the SSU 116 setting in the SSU 116 User Password is Setup field 92 using 27 Password Clear jumper 14, 75 Password on Boot, Setup field 92 Pause Before Boot, Setup field 88 PCDiagnostics, using 163 PCI buses 10 expansion slots 16 installation tips 168 PCI-A expansion slots 16 PCI-B expansion slots 16 PCI Configuration Setup field 87 Setup menu 88 PCI Device, Embedded SCSI Setup field 88 Setup menu 88 PCI Devices Setup field 89 Setup menu 89 peripheral component interconnect see PCI phonebook, EMP Console 140 Plug and Play OS, Setup field 87 port I/O 10 keyboard 19 mouse 19 USB 20 video 18 Port 80h codes 170 POST codes 170, 173 messages 170, 173 monitoring 163 using 127 power auxiliary power connector 22 configuration of modules 65 disabling power button 28 hot-swapping modules 65 installing a power supply module 67 installing fan in power supply bay 57 light does not light 164 main power connectors 21 module retention clip 66 power share board 65 removing a module 66 replacing a power supply module 67 supply characteristics 65 Power on/off remote server, EMP Console 138 Index 205 3424.boo Page 206 Wednesday, September 2, 1998 9:23 AM precautions, static electricity 2 preventing static electricity 2 Primary Master Setup field 85 Setup menu 86 Primary Slave Setup field 85 Setup menu 86 problem-solving procedures 162 processor first-level cache 21 heatsink 32, 36 installing 34, 38 installing second 36 MMX technology 21 multiprocessor capability 21 power support 20 removing 33 removing termination card 36 replacing 32 second-level cache 21 slots 21 supported 10 Processor Retest, Setup field 93 PS/2 Mouse, Setup field 90 R RAM, supported 10 random access memory see RAM RCA window SSU 112 using in SSU 112 Read Prefetch for PXB0A, Setup field 91 Read Prefetch for PXB0B, Setup field 91 rebooting the system 159 Recovery Boot jumper 14, 75 recovery, flash BIOS 101 redirect state, EMP Console 131 206 Maintaining and Troubleshooting the Gateway ALR 9200 Server regulatory specifications electromagnetic compatibility 190 safety compliance 194 Removable Devices, Setup field 95 removing 5.25-inch drive 52 access cover 3 adapter card 64 add-in board 64 DIMMs 41 diskette drive 45 EMI shield 50 expansion card 64 fan assembly 60 foam covers 60 foam fan cover 60 ISA board in the SSU 114 memory module 40 power supply module 66 processor 33 side panel 3 system fan 59 termination card 36 replacing access cover 8 battery 68 bezel 8 diskette drive 47 front bezel 8 power supply module 67 processor 32 side panel 8 requirements, EMP Console 132 reset button, disabling 28 Reset Configuration Data, Setup field 87 reset remote server, EMP Console 139 resetting the system 159 resolution, video, supported 19 resource configuration add-in see RCA 3424.boo Page 207 Wednesday, September 2, 1998 9:23 AM SEC, processor cartridge 10 second-level cache 21 Sectors, Setup field 86 secure boot mode, summary 28 secure mode 17 Secure Mode Boot, Setup field 93 Secure Mode Hot Key (Ctrl-Alt- ), Setup field 93 Secure Mode Timer, Setup field 92 secure mode, setting up in the SSU 27 security Administrator Password is Setup field 92 adminstrator password 28 boot without keyboard 29 both user and administrator passwords set 27 S chassis intrusion switch 26 safety clearing passwords 75 agency certification 194 control SSU access 28 compliance 194 disable diskette writes 28 important instructions x disabling power and reset static electricity precautions 2 buttons 28 SCSI diskette write protect connectors 12 monitoring 17 controllers 10 diskette write protection, Setup drive error LEDs 56 field 93 fans on high-power drives 57 EMP Password 133 heatsinks on high-power drives 54 Fixed Disk Boot Sector Setup hot-swapping a drive 56 field 92 mounting drive on carrier 55 Floppy Write Protect Setup field 93 narrow connector 12 front panel lock/unlock 17 SE 10 only user password set 27 using fans for high-power drives 57 options in the SSU 117 wide connector 12 Password on Boot Setup field 92 SDR Manager Add-in, SSU 120 secure boot mode 28 SDR Viewer secure mode 27 EMP Console 143 Secure Mode Boot Setup field 93 options 143 secure mode control 17 SDRR, storing system management Secure Mode Hot Key (Ctrl-Alt- ) data 16 Setup field 93 SE, SCSI 10 Secure Mode Timer Setup field 92 resources DMA usage 187 editing in the SSU 115 I/O addresses 178 interrupts 182 memory map 181 modifying in the SSU 114 usage shown in the SSU 115 video modes supported 183 restarting the system 159 Restreaming Buffer, Setup field 91 retention clip, power supply module 66 running Firmware Update utility 151 SSU locally 107 SSU remotely 107 Index 207 3424.boo Page 208 Wednesday, September 2, 1998 9:23 AM Set Administrator Password Setup field 92 set user password 29 Set User Password Setup field 92 setting the boot sequence 29 setting up in BIOS 26 setting up in SSU 26 Setup menu 92 software features 28 software locks 26 SSU add-in 116 timeout 28 User Password is Setup field 92 using passwords 27 video blanking 17 Video Blanking Setup field 93 Security Add-in, SSU 116 SEL Viewer EMP Console 141 options 142 SEL Viewer Add-in, SSU 118 sensor data record see SDR sensor data record repository see SDRR Serial Port A, Setup field 89 Serial Port B, Setup field 89 serial ports 19 server setting up for EMP 133 Setup menu 93 Server Configuration, EMP Console 133 server control, EMP Console operations 136 Server Management Mode, Setup field 94 server management module see SMM server management, managing the server 10 Set Administrator Password, Setup field 92 208 Maintaining and Troubleshooting the Gateway ALR 9200 Server Set User Password, Setup field 92 setting administrator password in the SSU 116 CMOS defaults 74 floppy drive A 85 floppy drive B 85 jumpers 73 recording BIOS settings 98 recording settings 81 server for EMP 133 user password in the SSU 116 Setup access 82 advanced chipset control menu 91 advanced menu 87 boot device priority menu 96 boot menu 95 console redirection menu 94 exit menu 97 fields 32 Bit I/O 86 Address Bit Permuting 91 Administrator Password is 92 Advanced Chipset Control 88 Assert NMI on AERR 94 Assert NMI on BERR 94 Assert NMI on PERR 94 Assert NMI on SERR 94 Base I/O Address, diskette controller 90 Base I/O Address, floppy disk controller 90 Base I/O Address, parallel port 90 Base I/O Address, serial port A 89 Base I/O Address, serial port B 90 Base RAM Step 91 Baud Rate 95 Boot Device Priority 95 Clear Event Logging 94 3424.boo Page 209 Wednesday, September 2, 1998 9:23 AM COM Port Address 94 Console Redirection 93 Cylinders 86 diskette check 95 diskette controller 90 diskette write protect 93 DMA Channel, parallel port 90 Enable Master, PCI device, embedded SCSI 88 Enable Master, PCI devices 89 Enabled Host Bus Error 94 Exit Discarding Changes 97 Exit Saving Changes 97 Extended RAM Step 91 Fixed Disk Boot Sector 92 Floppy Check 95 Floppy disk controller 90 Floppy Write Protect 93 Flow Control 95 Hard Disk Pre-delay 85 Hard Drive 95 Heads 86 I/O Device Configuration 87 Interrupt, parallel port 90 Interrupt, serial port A 89 Interrupt, serial port B 90 IRQ # 94 ISA Expansion Aliasing 91 Key Click 87 Keyboard auto-repeat delay 87 Keyboard auto-repeat rate 87 Keyboard Features 85 L2 Cache 91 Language 85 Large Disk Access Mode 88 Latency Timer, PCI device, embedded SCSI 88 Latency Timer, PCI devices 89 LBA Mode Control 86 Legacy Diskette A 85 Legacy Diskette B 85 Load Custom Defaults 97 Load Setup Defaults 97 Maximum Capacity 86 Maximum Number of I2O Drives 95 Memory Scrubbing 91 Message Timeout Multiplier 95 Mode, parallel port 90 Mode, serial port B 90 Multi-boot Support 95 Multi-Sector Transfers 86 Num Lock 87 Option ROM Scan, PCI device, embedded SCSI 88 Option ROM Scan, PCI devices 89 Parallel Port 90 Password on Boot 92 Pause Before Boot 88 PCI Configuration 87 PCI Device, Embedded SCSI 88 PCI Devices 89 Plug and Play OS 87 Primary Master 85 Primary Slave 85 Processor Retest 93 PS/2 Mouse 90 Read Prefetch for PXB0A 91 Read Prefetch for PXB0B 91 Removable Devices 95 Reset Configuration Data 87 Restreaming Buffer 91 Sectors 86 Secure Mode Boot 93 Secure Mode Hot Key (CtrlAlt- ) 93 Secure Mode Timer 92 Serial Port A 89 Serial Port B 89 Server Management Mode 94 Index 209 3424.boo Page 210 Wednesday, September 2, 1998 9:23 AM Set Administrator Password 92 Set User Password 92 System Backup Reminder 92 System Date 85 System Event Logging 94 System Management 93 System Time 85 Transfer Mode 86 Type 86 Ultra DMA 86 Use Multiprocessor Specification 87 User Password is 92 Video Blanking 93 Virus Check Reminder 92 floppy drive A field 85 floppy drive B field 85 hard drive menu 96 I/O device configuration menu 89 introduction 80 key commands 84 keyboard features menu 87 main menu 85 menus 83 PCI configuration menu 88 PCI device, embedded SCSI menu 88 PCI devices menu 89 primary master menu 86 primary slave menu 86 record settings 81 security menu 92 server menu 93 special display items 84 starting 82 system management menu 94 using 81 when to use 81 shared expansion slots 16 sharing power between modules 65 210 Maintaining and Troubleshooting the Gateway ALR 9200 Server side panel installing 8 removing 3 replacing 8 single edge contact see SEC single ended SCSI see SE, SCSI slot II connector, system board 21 small computer systems interface see SCSI SMBus connector 18 SMI, generating 17 SMM connector 18 software problems with applications 169 security features 28 trouble with new 160 solving problems 159, 162 speaker, connector 14 special display items in Setup 84 specific problems bootable CD_ROM is not detected 169 CD-ROM activity light does not light 168 characters are distorted or incorrect 166 diskette drive activity light does not light 167 hard disk activity light does not light 168 network problems 168 no beep codes 165 no characters appear onscreen 165 PCI installation tips 168 power light does not light 164 problems with applications 169 system cooling fans do not rotate properly 166 troubleshooting 164 3424.boo Page 211 Wednesday, September 2, 1998 9:23 AM specifications environmental 177 system 176 SSU access control 28 adding an ISA board 114 changing the administrator password 116 changing the user password 116 clearing the administrator password 116 clearing the user password 116 customizing 109 defining an ISA board 113 editing resources 115 exiting 124 FRU Manager Add-in 122 how to run 106 introduction 104 launching a task 111 modifying resources 114 Multiboot Options Add-in 115 RCA Window 112 removing an ISA board 114 resource usage 115 running locally 107 running remotely 107 SDR Manager Add-in 120 Security Add-in 116 security options 117 SEL Viewer Add-in 118 setting security 26 setting the administrator password 116 setting the user password 116 starting 108 using 105 using the RCA window 112 when to use 81, 105 standard VGA modes supported 183 starting Setup 82 SSU 108 static electricity precautions 2 status bar, EMP Console 135 subchassis closing 7 defined 5 opening 5 super video graphics array see SVGA supported CPUs 10 DIMMs 10 extended VGA modes 183 memory 10 monitors 19 processors 10 RAM 10 standard VGA modes 183 video modes 183 video resolutions 19 SVGA supported monitors 19 video controller 10 switch, chassis intrusion 26 Symbios SCSI utlity, using 152 system access 3 access control 29 battery 15 board, connectors 10 board, illustration 10 closing 7 cooling fans do not rotate properly 166 I/O addresses 178 I/O ports 10 installing fans 62 interrupts 182 intrusion monitoring 16 jumpers 13 memory map 181 opening 3 preparing for diagnostic testing 162 removing fans 59 Index 211 3424.boo Page 212 Wednesday, September 2, 1998 9:23 AM restarting 159 specifications 176 system board features 10 trouble at startup 159 troubleshooting new problems 161 System Backup Reminder, Setup field 92 system board management controller see BMC System Date, Setup field 85 system event log see SEL System Event Logging, Setup field 94 System Management Setup field 93 Setup menu 94 system management interrupt see SMI system management menu, EMP Console 133 system setup utility see SSU System Time, Setup field 85 T technical specifications 176 temperature, monitoring 16, 18 termination card, removing 36 testing add-in video controller 165 preparing for diagnostics 162 text formatting in this guide ix timeout, security 28 toolbar, EMP Console 135 Transfer Mode, Setup field 86 troubleshooting bootable CD-ROM is not detected 169 CD-ROM drive activity light does not light 168 characters are distorted or incorrect 166 checklist 158 212 Maintaining and Troubleshooting the Gateway ALR 9200 Server confirming operating system load 164 diskette drive activity light does not light 167 flash update recovery 75 flash update recovery beep codes 76 guidelines 158 hard disk drive activity light does not light 168 initial system startup 159 network problems 168 new battery 69 no beep codes 165 no characters appear onscreen 165 PCI installation tips 168 power light does not light 164 problems with applications 169 problems-solving procedures 162 running new software 160 solving problems 159 specific problems 164 system cooling fans do not rotate properly 166 system has been running fine 161 system LED failures 163 Type, Setup field 86 U Ultra DMA, Setup field 86 universal serial bus see USB upgrade BIOS 98, 100 creating bootable diskette 99 obtaining the BIOS upgrade utility 98 usage data, FRU and SDR load utility 147 USB bus speed 20 internal connector 15 port 20 3424.boo Page 213 Wednesday, September 2, 1998 9:23 AM Use Multiprocessor Specification, Setup field 87 User Password is, Setup field 92 user password, access 27 using CFG files with the FRU and SDR load utility 149 Firmware Update utility 151 FRU and SDR load utility 146 passwords 27 PCDiagnostics 163 POST 127 resources from the SSU 115 Setup 81 SSU 105 Symbios SCSI utility 152 utility FRU and SDR load 145 obtaining to upgrade BIOS 98 W wake-on-LAN technology connector 14 when to run the FRU and SDR load utility 145 when to run the SSU 105 wide SCSI connectors 12 V verifying the configuration 158 VGA extended modes supported 183 standard modessupported 183 video blanking 17 connector 18 controller 10 installing drivers 77 memory installed 10 modes supported 183 supported resolutions 19 SVGA controller 10 Video Blanking, Setup field 93 Virus Check Reminder, Setup field 92 virus notice 155 voltage monitoring 16, 18 voltage regulator module see VRM VRM connectors 20 second-level cache 20 Index 213 3424.boo Page 214 Wednesday, September 2, 1998 9:23 AM 214 Maintaining and Troubleshooting the Gateway ALR 9200 Server
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 1998:09:02 09:39:50 Producer : Acrobat Distiller 3.01 for Windows Title : Gateway ALR 9200 Server Creator : FrameMaker 5.5P4f Subject : Maintaining and Troubleshooting Author : Information Development Modify Date : 1999:04:16 11:14:27 Page Count : 226 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools