Installation Instructions

GT1TM LED Pedestrian 16x18’’ Incandescent Look
Signal Modules / PS7-CFF1-46A-J & PS7-CFF1-26A-J
Full Hand/Person Overlay/Countdown

BEFORE YOU BEGIN

Prepare Electrical Wiring
Electrical Requirements

Read these instructions completely and carefully.




Do not use in wet locations
Follow all National Electric Codes
(NEC) and local codes.

Installation Steps:
1.
2.
3.
4.

Verify input voltage is within specified range on the back of the LED signal module before
installation. Failure to do so will cause lamp to fail.
Open front cover of (customer supplied) traffic signal housing.
Connect the wires to the appropriate terminal block within customer supplied signal housing.
(Orange wire (+ for Hand), Blue Wire (+ for Person) and White wire (for the neutral).
Close front cover of (customer supplied) traffic signal housing ensuring that the module gasket is
tight within the housing.

16 x 18 inch Overlay / Countdown
Risk of Electric Shock
Install unit in enclosure tested to
be suitable for wet locations only.

Back of 16 x 18 inch Pedestrian Module
Blue Wire

White Wire

Orange Wire

Voltage Rating

Countdown Option
Jumpers
(See next page)

…Page 2

Installation Instructions (cont’d)

GT1TM LED Pedestrian 16x18’’ Incandescent Look
Signal Modules / PS7-CFF1-46A-J & PS7-CFF1-26A-J
STEP A
To Test Countdown
Note: Module does not need to be disconnected from terminal block.
1. Remove Cap from "CONNECT TO TEST"
2. Connect jumper wire using appropriate screws.
3. Re-install Cap over jumper location
To Stop Testing Countdown
1. Remove Cap from "CONNECT TO TEST"
2. Disconnect jumper wire and store it for future use (as shown on Figure A).
3. Re-install Cap over jumper wire
STEP B
To Disable Countdown
Note: Module does not need to be disconnected from terminal block.
1. Remove Cap from "DISCONNECT TO DISABLE"
2. Remove jumper wire and replace screws for future use.
3. Re-install Cap over jumper location
To Re-Enable Countdown
1. Remove Cap from "DISCONNECT TO DISABLE"
2. Re-install jumper wire using appropriate screws (as shown on Figure B).
3. Re-install cap over jumper wire.

Risk of Electric Shock
Step A:
Connect Jumper
wire to Test
Countdown

Install unit in enclosure tested
to be suitable for wet locations
only.

Fig. A

Step B:
Disconnect Jumper
wire to Disable
Countdown

Fig. B

GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1-888-69-43-533
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. GT1 is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the
General Electric Company. © 2010 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when
measured under laboratory conditions.
TRAF059-R120110



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : GE LED Transportation Signal Lighting
Create Date                     : 2010:12:09 11:11:37-05:00
Keywords                        : ge lighting, LED lighting, Transportation, Traffic signal lighting, Pedestrian Modules, GT1 16x18inch Incandescent, Install Guide, Full Hand, Person Overlay, Countdown
Modify Date                     : 2013:08:27 17:48:18-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : GE LED Transportation Signal Lighting
Title                           : GE LED Transportation Traffic Signal Lighting Pedestrian Modules GT1 16x18inch Incandescent Install Guide | GE Lighting
Description                     : Learn how to install the GE LED Transportation Traffic Signal Lighting Pedestrian Modules GT1 16x18inch Incandescent. This file provides installation instructions such as electrical wiring for the GE LED Transportation Traffic Signal Lighting Pedestrian Modules GT1 16x18inch Incandescent - Full Hand, Person Overlay, and Countdown.
Subject                         : ge lighting, LED lighting, Transportation, Traffic signal lighting, Pedestrian Modules, GT1 16x18inch Incandescent, Install Guide, Full Hand, Person Overlay, Countdown
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:08:27 17:48:18-04:00
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Document ID                     : uuid:41485cf6-40b4-4d7a-a175-1014caa38dff
Instance ID                     : uuid:1934b918-7c72-4503-96ba-f7fc565f0b76
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu