Installation Instructions
GT1TM LED Pedestrian 16x18’’ Incandescent Look
Signal Modules / PS7-CFF1-46A-J & PS7-CFF1-26A-J
Full Hand/Person Overlay/Countdown
Installation Steps:
1. Verify input voltage is within specified range on the back of the LED signal module before
installation. Failure to do so will cause lamp to fail.
2. Open front cover of (customer supplied) traffic signal housing.
3. Connect the wires to the appropriate terminal block within customer supplied signal housing.
(Orange wire (+ for Hand), Blue Wire (+ for Person) and White wire (for the neutral).
4. Close front cover of (customer supplied) traffic signal housing ensuring that the module gasket is
tight within the housing.
…Page 2
Back of 16 x 18 inch Pedestrian Module
Risk of Electric Shock
Install unit in enclosure tested to
be suitable for wet locations only.
Voltage Rating
Blue Wire White Wire Orange Wire
Countdown Option
Jumpers
(See next page)
16 x 18 inch Overlay / Countdown
Prepare Electrical Wiring
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Electrical Requirements
Do not use in wet locations
Follow all National Electric Codes
(NEC) and local codes.
Installation Instructions (cont’d)
GT1TM LED Pedestrian 16x18’’ Incandescent Look
Signal Modules / PS7-CFF1-46A-J & PS7-CFF1-26A-J
STEP A
To Test Countdown
Note: Module does not need to be disconnected from terminal block.
1. Remove Cap from "CONNECT TO TEST"
2. Connect jumper wire using appropriate screws.
3. Re-install Cap over jumper location
To Stop Testing Countdown
1. Remove Cap from "CONNECT TO TEST"
2. Disconnect jumper wire and store it for future use (as shown on Figure A).
3. Re-install Cap over jumper wire
STEP B
To Disable Countdown
Note: Module does not need to be disconnected from terminal block.
1. Remove Cap from "DISCONNECT TO DISABLE"
2. Remove jumper wire and replace screws for future use.
3. Re-install Cap over jumper location
To Re-Enable Countdown
1. Remove Cap from "DISCONNECT TO DISABLE"
2. Re-install jumper wire using appropriate screws (as shown on Figure B).
3. Re-install cap over jumper wire.
Risk of Electric Shock
Install unit in enclosure tested
to be suitable for wet locations
only.
Step B:
Disconnect Jumper
wire to Disable
Countdown
Step A:
Connect Jumper
wire to Test
Countdown
Fig. A
Fig. B
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. GT1 is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the
General Electric Company. © 2010 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when
measured under laboratory conditions.
TRAF059-R120110

Navigation menu