Ge Isovolt Titan E Brochure
Ge-Isovolt-Titan-E-Brochure-648867 ge-isovolt-titan-e-brochure-648867
2015-03-09
: Ge Ge-Isovolt-Titan-E-Brochure-648867 ge-isovolt-titan-e-brochure-648867 ge pdf
Open the PDF directly: View PDF .
Page Count: 7
Download | |
Open PDF In Browser | View PDF |
GE Sensing & Inspection Technologies The ISOVOLT Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators is based on the proven ISOVOLT platform, which offers more than 25 years experience with thousands of installations across the world. A wide range of systems is provided. Generators and tubes can be 160 kV, 225 kV, 320 kV, 420 kV or 450 kV, and can be operated from as low as 5 kV or a current range exceeding up to 45 mA*. Designed for radiography, radioscopy, radiometry and life-science applications, which place the highest demands on reliability and exposure quality, the range of Titan E generators and accessories meets the different degrees of automation and customization, required throughout the industrial and scientific sectors. Titan E control is a modern, state-of-the-art industrial control module for fail-safe and intuitive system operation. A powerful range of suitable accessories complements the integration and application capabilities for all facets of industrial or scientific environments. Unique Features at a Glance Highest exposure quality A reproducibility of ± 0.01 % for tube current (mA) and tube voltage (kV) provides highest possible stability of radiation dose rate with fluctuations < 0.05 %. This excellent dose reproducibility fits both, Titan E applications that demand the highest accuracy, such as calibration of detectors or dosimeters, as well as radiography applications. Extremely low ripple ensures outstandingly stable High Voltage for optimized material penetration with excellent efficiency factors. The extended tube range of 5 kV to 450 kV in conjunction with the excellent maximum current of 45 mA*, ensures optimized imaging contrast and very high penetration power. This results in short exposure times in various operation modes for different material. Highest device availability Continuous improvements on critical system parameters to increase robustness and resistance against external influences, guarantee high system up-times that give the operator steady revenue streams and perfect time utilization. Stackable and modular design allows easy field service. Automatic event recording provide instant information for process control and system diagnosis either on site or via optional remote access. Unmatched ramp-up times (< 1.5 sec) support applications requiring fast inspection cycles*. 100% duty cycle, for continuous operation in in-line systems**. Optimized equipment performance results in increased productivity and reduced total cost of ownership. Easy to integrate The stand-alone control module is available in both, a rugged and ergonomic desktop housing, and also as 19” adapter version, for easy control-desk integration. The Titan E considers typical OEM needs, providing kits, interfaces and protocols for all kinds of industrial system integration (RS 232, Profibus). The design permits intuitive and fatigue-proof operation through a large graphical display, rotary knob control, function keys and a keypad for fast and direct inputs. The control interacts with the operator in clear text with four international character sets and 16 languages. It allows full external control of X-ray equipment and simplifies remote visualization – even without connecting the control module. Extension of diagnosis capabilities by remote access via Internet or dial-up line is available as an option. Selected tubes feature maintenance-free High voltage connections, ensuring highest productivity, while minimizing operational risks. Fully automated tube warm-up procedures safeguard tube operation and ensure maximum tube life. Highest device performance Rugged generator design with intelligent tube integration and permanent system monitoring, ensure highest performance, from peaked intermittent, up to permanent 24/7 operation**. This results in consistent performance over various exposure modes and operation conditions. Smart user interaction Flexible usage Intelligent and safe operation Automatic tube configuration in conjunction with real time clock powered automated warm-up procedures enhance operational safety and maximize equipment lifetime. Built for a wide range of applications in different environmental conditions, Titan E generator solutions are for all NDT needs, life science applications and also measurement and calibration tasks. On board electronics feature reserved memory for up to 250 programmable operation modes, records of the last 128 warm-up cycles and 512 operation event-logs and a structured setup menu for individual performance settings. Titan E is available in 3-phase, 400 V or single-phase, 230 V input power rating. As a result easy integration into different power environments without regional limitations is possible. Built in safety features such as redundant interlock monitoring, cooling flow rate watchdog signals, operating temperature and other system status information are visible on the operation display. This leads to instant recognition of system status and health. *) depending on permissable tube data **) subject to optional generator cooling 2 3 Titan E Control Benefits A user-friendly, multi-language control features a clear full-graphical display, that allows simultaneous readings of set and actual operating parameters. Embedded in an ergonomic and rugged desktop or optional 19” rack mounting housing, full control for X-ray operation is established. Intuitive guidance through diverse menus as well as unmistakable messages for clear interventions are provided with this module. Proven platform serving broad range of applications The operating concept provides interaction with turning speed sensitive rotary knob, function keys, a numberic keypad and safety relevant buttons for X-ray operation as well as a key switch. The multifunctional rotary knob can be used to set kV, mA, exposure time and several configuration settings. By a progressive change of voltage and current via rotary knob the kV and mA settings can be accurately changed with different granulations of 0.1kV / 1 kV / 10 kV respectively 0.01 mA (if enabled) / 0.1 mA / 1 mA. This allows optimized one-hand operation for radioscopy and many other applications. • Tube protection due to automatic warm-up procedures and extended warm-up modes to safeguard tube performance. • Smart and intuitive user interaction, with several integration possibilities facilitating higher productivity. • Excellent dose reproducability with extremely stable high voltage section for optimized exposures. • Convenient integration into several external platforms, such as automated testing machines, leveraging different interface features for device control, monitoring and visualization. • Excellent endurance and performance for permanent or intermittent operation. • Less intensive maintenance combined with easier serviceability reduces total cost of ownership. • Broad range of tubes, accessories and kits available. Features such as free configurable exposure programmes, or special programmes for constant power, constant current and manual operation cater for individual demands for radiographic or radioscopic inspections. The multi-lingual user display with 16 different languages and extended character sets for Japanese, Cyrillic and Chinese enables comprehensible and simple interaction. Optional, the entire system control with graphical visualization can be done via a stand-alone PC based platform. Titan E provides automatic and manual warm-up modes for optimized tube conditioning. A special extended warm-up mode safeguards tube performance under severe conditions and setups. 4 5 Isovolt Selection of unipolar Tubes* ISOVOLT 160 M2 0.4-1.5 ISOVOLT 160 M2 0.4-3.0 ISOVOLT 160 M2 0.4-0.4HP ISOVOLT 160 MM2/ HP ISOVOLT 160 MC2 ISOVOLT 160 M1 ISOVOLT 225 M2 0.4-3.0 ISOVOLT 225 M2 0.4-1.5 ISOVOLT 225 MM2/ HP Max. Tube Voltage (kV) 160 160 160 160 160 160 225 225 225 Tube Current (mA) (at Max. Tube Voltage) 10 4 1600 640 1.5 0,4 3.00 1.00 19 4 3000 640 3.0 0.4 5.50 1.00 6 6 1000 1000 0.4 0.4 1.00 1.00 11 5 1800 800 6 15,6 5.6 2500 900 0.40 x 4.00 3.00 1.00 7.0 3.0 1600 640 1.5 0.4 3.00 1.00 8 3.5 1800 800 1.00 0.40 13 3.0 3000 640 3.0 0.4 5.50 1.00 Inherent Filtration (mm) 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be Emergent Beam Angle 40° 40° 40° 30° x 40° Asym. 0.5 Ti + 2.0 H20 + 2.0 AI 40° x 360° Sym. 40° 40° 40° 30° x 40° Asym. 8.5 (18.7) 8.5 (18.7) 8.5 (18.7) 8.5 (18.7) 8.0 (17.6) 8.5 (18.7) 11.9 (26.2) 11.9 (26.2) 11.9 (26.2) ISOVOLT 320/7 ISOVOLT 320 M2 4.5 - 13 ISOVOLT 320/13 ISOVOLT 320 M2 0.4 - 1.0 HP ISOVOLT 420/5 ISOVOLT 450/5 ISOVOLT 450/10 ISOVOLT 450 M2/10 ISOVOLT 450 M2 0.4 - 1.0 HP Max. Tube Voltage (kV) 320 320 320 320 420 450 450 450 450 Tube Current (mA) (at Max. Tube Voltage) 7 3 2240 960 1.8 0.8 3.60 1.90 13 4.5 4200 1500 4.0 1.5 5.50 3.00 13 5 4200 1680 3.5 1.5 6.30 3.00 5.6 2.5 1800 800 5 2.1 2240 960 1.5 0.8 3.6 1.90 10 3.7 4500 1680 3.5 1.5 6.30 3.00 10 2 4500 900 3.0 1.2 5.50 2.50 3.3 1.5 1500 700 1.00 0.40 5.3 2.3 2240 960 1.5 0.8 3.60 1.90 Inherent Filtration (mm) 7.0 / Be 3.0 / Be 7.0 / Be 3.0 / Be 7.0 / Be 7.0 / Be 7.0 / Be 5.0 / Be 5.0 / Be Emergent Beam Angle 20° x 40° 40° 40° 30° x 40° Asym. 20° x 40° 20° x 40° 40° 40° 30° x 40° Asym. 40 (88) 40 (88) 40 (88) 40 (88) 90 (198) 90 (198) 90 (198) 90 (198) 90 (198) Max. Anode Dissipation (W) Nom. Focal Spot Value IEC 336 Focal Spot Size EN 12 543 (mm) Weight (kg (lbs)) Accessories Safety devices • Primary interlock switch Integration and solution kits • Exposure Calculator (PC Software) • Alarm box • Switch box • Titan E PC (External PC based visualization) • Flash- and warning lamps • PROFIBUS Extension Kit • Country specific safety kits HV cables • In different standard lengths, with quick-lock or flange connections with rubbercone plugs or maintenance-free angle plugs. 1000 0.3 x 3 1.00 0.40 Selection of bipolar Tubes* Dosimetry and calibration kits • Voltage divider (incl. PTB certification) Max. Anode Dissipation (W) Pumps and coolers (See pictures below) Nom. Focal Spot Value IEC 336 Focal Spot Size EN 12 543 (mm) Weight (kg (lbs)) 1.00 0.40 * The ISOVOLT Titan E series can be equipped with various types of tube housing to suit your application. Ask your GE v representative for an application specific consultation and a full list of tube housings WL 3000 SE 6 OW 4002 OL 4503 OLK 50 Voltage Divider Maintenance free angle plug Junction Kits and Safety Devices Diaphragms Column Stand 7 System Layout for Exemplary Setups Bipolar Operation Unipolar operation (1) (1) (2) (4a) (8a) (4b) (4a) (2) (3) (3) (6a) (6b) (5) (5) (5) (5) (7a) (1) Mains connecting cable, standard length 10 m / 32 ft, with wire end ferrules (6a) Unipolar Tube Housing (see tube overview or separate product information) (2) Control Module ISOVOLT Titan E in desktop housing (optional 19” rack house) (6b) Bipolar Tube Housing (see tube overview or separate product information) (3) Connecting cable control/power stage, standard length 10 m (max. 100 m) / 32 ft. (max. approx 320 ft.) (7a) Water hoses, standard length 10 m (max. 20 m) / 16 ft (max. 32 ft) (4b) High Voltage Generator, 160 kV or 225 kV, Anode incl. Connecting cable (7b) Input and output connections Legend (4a) High Voltage Generator, 160 kV or 225 kV, Cathode, with integrated power module Titan E (8b) (7b) Cooling Oil hoses, standard length 6m (max. 20 m) / 19 ft (max. 64 ft) (8a) Water Cooling Pump with built in flow rate monitor, see separate specification • • • • • • • • RS 232 interface for connection of machine controls Interlock as per DIN 54113. Interlock as per United States Radiation Control Act of 1968, § 1020.40. Additional warning output that is active during pre-warning time. External START/STOP. External EMERGENCY-STOP. Cooling system. External warning flash lamp (fail-safe). • • • • • “Mains ON” (230V / 2A2). “High Voltage ON” (230V / 2A2). Potential-free contact, for “Mains ON” (60V AC / 75V DC / 2A1). Potential-free contact, for “Pre-warning Time ON” (30V AC/36V DC / 0.5A1). Potential-free contact, for “High Voltage ON” (60V AC / 75V DC / 2A1). 1) This voltage corresponds to the max. operating voltage (rating as per VDE 0110 Group B). 2) These 230 V contacts are collectively fused with 2.5 A. (8b) Oil Cooling Pump, see separate specification (5) High Voltage Cables, 160 kV or 225 kV, standard length 5 m / 16 ft (max. 20 m / 64 ft for 160 kV - 320 kV; max. 10 m / 32 ft for 420 kV and 450 kV) 8 9 Technical Specifications Unipolar Systems Bipolar Systems High Voltage Generator Max. Output Voltage Max. Output Current Max. Output Power High Voltage Ripple Insulation Housing Dimensions (Cathode) (W x D x H) Weight (Cathode) 160 kV 45 mA 4,5 kW, Limited by Tube Specification 5 V/mA (With High Voltage Cable 10 m), 40 kHz Oil 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”) 189 kg (417 lbs), Including Power Module 225 kV 45 mA 4,5 kW, Limited by Tube Specification 5 V/mA (With High Voltage Cable 10 m), 40 kHz Oil 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”) 189 kg (417 lbs), Including Power Module Tube Voltage Preselection and Setting Digital Display of Set and Actual Values Display Resolution Accuracy Reproducibility Temperature Drift From 5 to 160 kV in 0.1 kV / 1 kV / 10 kV Simultaneous 4 Digits Each 0.1 kV < ±1% ±0.01% at Constant Temperature Level < 65 ppm/°C From 5 to 225 kV in 0.1 kV / 1 kV / 10 kV Simultaneous 4 Digits Each 0.1 kV < ±1% ±0.01% at Constant Temperature Level < 65 ppm/°C Tube Current Preselection and Setting Digital Display of Set and Actual Values Display Resolution Accuracy Reproducibility Temperature Drift From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA Simultaneous 4 Digits Each 0.1 mA / 0.01 mA ± 1% ± 0.01% at Constant Temperature Level < 65 ppm/°C From 0.1 to 45 mA in in 0.01 mA / 0.1 mA / 1 mA Simultaneous 4 Digits Each 0.1 mA / 0.01 mA ±1% ± 0.01% at Constant Temperature Level < 65 ppm/°C Non-Volatile Memory From 0.1 to 99.9 Minutes in 0.1 Min. Increments or from 1 to 999 Sec. in 1 Sec. Increments or as direct Min./Sec. value (up to 99’59”) The Remaining Time Is Displayed, i.e. After a Mains Failure Exposure Can Be Continued Without any Time Error Non-Volatile Memory From 0.1 to 99.9 Minutes in 0.1 Min. Increments or from 1 to 999 Sec. in 1 Sec. Increments or as direct Min./Sec. value (up to 99’59”) The Remaining Time Is Displayed, i.e. After a Mains Failure Exposure Can Be Continued Without any Time Error Digital Setting From 2 to 250 Seconds or de-activated Digital Setting From 2 to 250 Seconds or de-activated Operation History 250 Automatic Intelligent Tube conditioning based on Real-time Clock Extended warm-up for special conditioning 8 Tube selectable from a database of > 40 pre-programmed tubes 512 Events (256 On/Off Events) 250 Automatic Intelligent Tube conditioning based on Real-time Clock Extended warm-up for special conditioning 8 Tube selectable from a database of > 40 pre-programmed tubes 512 Events (256 On/Off Events) Warm-up History 128 Events 128 Events 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”) Built into Desk Housing 4.9 kg (10.8 lbs) Including Desk Housing 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”) Built into Desk Housing 4.9 kg (10.8 lbs) Including Desk Housing 1N PE 230 V ± 10% 50/60 Hz 3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase, Grounded Neutral TN-S or TN-C-S Mains (Star Connected System, Optional 3-Phase Isolation Transformer) Separate Grounding for X-ray Tube and High Voltage Generator (Minimum 6 mm2) 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses, Customer-Supplied 0°C to +40°C -30°C to +70°C 1N PE 230 V ± 10% 50/60 Hz 3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase, Grounded Neutral TN-S or TN-C-S Mains (Star Connected System, Optional 3-Phase Isolation Transformer) Separate Grounding for X-ray Tube and High Voltage Generator (Minimum 6 mm2) 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses, Customer-Supplied 0°C to +40°C -30°C to +70°C Exposure Time Programmable Timer Preselection and Setting Digital Display of Set and Actual Values Prewarning Time Preselection and Setting Programmed Mode Number of Storable Programs Warm-Up X-ray Tube Setup Control Module Dimensions (W x D x H) Weight Connected Loads Power connection Grounding Mains Fuses Operating Temperature Range Storage Temperature Range High Voltage Generator Max. Output Voltage Max. Output Current Max. Output Power Weight (Anode) Weight (Cathode) -160 kV (Cathode), +160 kV (Anode) 45 mA 4,5 kW (Cathode) 3 kW (Anode) Limited by Tube Specification 10 V/mA (With High Voltage Cable 10 m), 40 kHz Oil 512 Events (256 On / Off events) 128 Events 350 x 870 x 620 mm (13.8” x 34.3” x 24.4”) 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”) 123 kg (272 lbs) 189 kg (417 lbs), Including Power Module -225 kV (Cathode), +225 kV (Anode) 45 mA 4,5 kW (Cathode) 3 kW (Anode) Limited by Tube Specification 10 V/mA (With High Voltage Cable 10 m), 40 kHz Oil 512 Events (256 On / Off events) 128 Events 350 x 870 x 620 mm (13.8” x 34.3” x 24.4”) 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”) 123 kg (272 lbs) 189 kg (417 lbs), Including Power Module Tube Voltage (Anode) Preselection and Setting Digital Display of Set and Actual Values Display Resolution Accuracy Reproducibility Temperature Drift From 5 to 320 kV in 0.1 kV / 1 kV / 10 kV Simultaneous 4 Digits Each 0.1 kV < ±1% ±0.01% at Constant Temperature Level < 65 ppm/°C From 5 to 450 kV in 0.1 kV / 1 kV / 10 kV Simultaneous 4 Digits Each 0.1 kV < ±1% ±0.01% at Constant Temperature Level < 65 ppm/°C Tube Current Preselection and Setting Digital Display of Set and Actual Values Display Resolution Accuracy Reproducibility Temperature Drift From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA Simultaneous 4 Digits Each 0.1 mA / 0.01 mA ± 1% ± 0.01% at Constant Temperature Level < 65 ppm/°C From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA Simultaneous 4 Digits Each 0.1 mA / 0.01 mA ±1% ± 0.01% at Constant Temperature Level < 65 ppm/°C Non-Volatile Memory From 0.1 to 99.9 Minutes in 0.1 Min. Increments or From 1 to 999 Sec. in 1 Sec. Increments or as direct Min./Sec. value (up to 99’59”) The Remaining Time Is Displayed, i.e. After a Mains Failure Exposure Can Be Continued Without any Time Error Non-Volatile Memory From 0.1 to 99.9 Minutes in 0.1 Min. Increments or From 1 to 999 Sec. in 1 Sec. Increments or as direct Min./Sec. value (up to 99’59”) The Remaining Time Is Displayed, i.e. After a Mains Failure Exposure Can Be Continued Without any Time Error Digital Setting From 2 to 250 Seconds or de-activated Digital Setting From 2 to 250 Seconds or de-activated 250 Automatic Intelligent Tube conditioning based on Real-time Clock Extended warm-up for special conditioning 8 Tube selectable from a database of > 40 pre-programmed tubes 250 Automatic Intelligent Tube conditioning based on Real-time Clock Extended warm-up for special conditioning 8 Tube selectable from a database of > 40 pre-programmed tubes 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”) Built into Desk Housing 4.9 kg (10.8 lbs) Including Desk Housing 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”) Built into Desk Housing 4.9 kg (10.8 lbs) Including Desk Housing 1N PE 230 V ± 10% 50/60 Hz 3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase, Grounded Neutral TN-S or TN-C-S Mains (Star Connected System, Optional 3-Phase Isolation Transformer) Separate Grounding for X-ray Tube and High Voltage Generator (Minimum 6 mm2) 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses, Customer-Supplied 0°C to +40°C -30°C to +70°C 1N PE 230 V ± 10% 50/60 Hz 3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase, Grounded Neutral TN-S or TN-C-S Mains (Star Connected System, Optional 3-Phase Isolation Transformer) Separate Grounding for X-ray Tube and High Voltage Generator (Minimum 6 mm2) 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses, Customer-Supplied 0°C to +40°C -30°C to +70°C High Voltage Ripple Insulation Operation History Warm-up History Housing Dimensions (Cathode) (W x D x H) Exposure Time Programmable Timer Preselection and Setting Digital Display of Set and Actual Values Prewarning Time Preselection and Setting Programmed Mode Number of Storable Programs Warm-Up X-ray Tube Setup Control Module Dimensions (W x D x H) Weight Connected Loads Power connection Grounding Mains Fuses Operating Temperature Range Storage Temperature Range 10 11 Regional Contact Information GE Sensing & Inspection Technologies Bogenstrasse 41 22926 Ahrensburg Germany +49 4102 8070 GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044 USA +1 717 242 0327 GE Sensing & Inspection Technologies Robert Bosch Strasse 3 50354 Huerth Germany +49 2233 6010 GE Sensing & Inspection Technologies 5F, Hongcao Building 421 Hongcao Road Shanghai 200233 China +86 800 820 1876 (China toll free) +86 21 3414 4620 (ext. 6029) www.gesensinginspection.com GEIT-30167EN(05/09) © 2009 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56 Instance ID : uuid:a77429e1-3ea2-4a18-be65-513303dd4c79 Document ID : adobe:docid:indd:dc7f9da0-16b8-11dd-9b72-b617b0ce9091 Rendition Class : proof:pdf Derived From Instance ID : dc7f9d9f-16b8-11dd-9b72-b617b0ce9091 Derived From Document ID : adobe:docid:indd:786a8896-f0f2-11dc-94a7-84d0c46f6dfc Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 75.00, 72.00, 300.00, 300.00, 75.00, 300.00, 300.00, 75.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 75.00, 72.00, 300.00, 300.00, 75.00, 300.00, 300.00, 75.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:7C50DCD3F05311DC8FCBBC6C93B6AB24, uuid:82b4576a-70df-415d-bdc7-4d3c4251e0d1, uuid:4F342ED0CC1111DCB3E2FED19896479A, uuid:60A3652DCC1111DCB3E2FED19896479A, uuid:20B33E3CCC1111DCB3E2FED19896479A, uuid:323E1072CC1211DCB3E2FED19896479A, uuid:CBA806FF7A4811DC8953C29FB14FD13D, uuid:2E273238CC1111DCB3E2FED19896479A, uuid:8C2C4CC2CC1111DCB3E2FED19896479A, uuid:CBA806FF7A4811DC8953C29FB14FD13D, uuid:4F342ED0CC1111DCB3E2FED19896479A, uuid:60A3652DCC1111DCB3E2FED19896479A, uuid:2E273238CC1111DCB3E2FED19896479A, uuid:323E1072CC1211DCB3E2FED19896479A, uuid:20B33E3CCC1111DCB3E2FED19896479A, uuid:8C2C4CC2CC1111DCB3E2FED19896479A, uuid:8E7F9B8BF0F411DCA14890E1BD678515, uuid:E45138B3F0F911DCA14890E1BD678515, uuid:F704B8EFF75911DC8C79F99889A0F0A1, uuid:B93992C3F0F711DCA14890E1BD678515, uuid:B784745CF75C11DC8C79F99889A0F0A1, uuid:34F22C55CB4911DCB3E2FED19896479A, uuid:9F49795716BB11DDAFBE808894E0F13C, uuid:B423F6E7F0DC11DC8756CB1939EBA4E9, uuid:CE4A6CD6F11011DCA77C9B4E16D73E38, uuid:E32850FCF74E11DC8C79F99889A0F0A1, uuid:D8D04491F10311DCA14890E1BD678515, uuid:42E45FEAF10211DCA14890E1BD678515, uuid:9E44A64CF10111DCA14890E1BD678515, uuid:FB72D418F10011DCA14890E1BD678515, uuid:9BF6EC72F74F11DC8C79F99889A0F0A1, uuid:2AEAD009F0FA11DCA14890E1BD678515, uuid:33C8BB51F10B11DCA77C9B4E16D73E38, uuid:8FE8C7ECF8E111DC8509A6B07552B1F8, uuid:5114AF1716B111DDAFBE808894E0F13C, uuid:4FF3CE57F10B11DCA77C9B4E16D73E38, uuid:346658E8E26D11DC827BC6338D8CD45D, uuid:21302C78F75011DC8C79F99889A0F0A1, uuid:3D5A0944E26C11DC827BC6338D8CD45D, uuid:F8DD93D4E26711DC827BC6338D8CD45D, uuid:346658E8E26D11DC827BC6338D8CD45D, uuid:2C8FF9DDF10D11DCA77C9B4E16D73E38, uuid:2C8FF9DDF10D11DCA77C9B4E16D73E38, uuid:3D5A093DE26C11DC827BC6338D8CD45D, uuid:17240556F10D11DCA77C9B4E16D73E38, uuid:438cb973-ce41-11db-b906-885e687027c1, uuid:6cddbe45-0df5-11dc-a335-000d9345385c Manifest Reference Document ID : uuid:3BB610E6F05311DC8FCBBC6C93B6AB24, uuid:08328253-029f-11db-8319-000d9345385c, uuid:4F342ECFCC1111DCB3E2FED19896479A, uuid:60A3652CCC1111DCB3E2FED19896479A, uuid:F9DB37CECC1011DCB3E2FED19896479A, uuid:849BB7DACC1111DCB3E2FED19896479A, uuid:CBA806FE7A4811DC8953C29FB14FD13D, uuid:2E273237CC1111DCB3E2FED19896479A, uuid:8C2C4CC1CC1111DCB3E2FED19896479A, uuid:CBA806FE7A4811DC8953C29FB14FD13D, uuid:4F342ECFCC1111DCB3E2FED19896479A, uuid:60A3652CCC1111DCB3E2FED19896479A, uuid:2E273237CC1111DCB3E2FED19896479A, uuid:849BB7DACC1111DCB3E2FED19896479A, uuid:F9DB37CECC1011DCB3E2FED19896479A, uuid:8C2C4CC1CC1111DCB3E2FED19896479A, uuid:8E7F9B8AF0F411DCA14890E1BD678515, uuid:05BB3BC3F0F811DCA14890E1BD678515, uuid:37C6B280F75311DC8C79F99889A0F0A1, uuid:F7488089F0F611DCA14890E1BD678515, uuid:B7847454F75C11DC8C79F99889A0F0A1, uuid:ED208796CA6011DCB3E2FED19896479A, uuid:2BFD9B18F11611DCA77C9B4E16D73E38, uuid:B423F6E6F0DC11DC8756CB1939EBA4E9, uuid:CE4A6CD5F11011DCA77C9B4E16D73E38, uuid:E32850F2F74E11DC8C79F99889A0F0A1, uuid:42E45FF2F10211DCA14890E1BD678515, uuid:13DF71C4F0E811DCA14890E1BD678515, uuid:07D6641DF0E811DCA14890E1BD678515, uuid:2D2DFF0EF0E811DCA14890E1BD678515, uuid:EDA354D0F74E11DC8C79F99889A0F0A1, uuid:F7B52A70F0E711DCA14890E1BD678515, adobe:docid:photoshop:86a0fe2e-e7b8-11dc-8d15-b8facd193f94, uuid:9ADBE0CBF10611DCA14890E1BD678515, uuid:ABCF6BEDF74F11DC8C79F99889A0F0A1, uuid:F6F3DE33F10611DCA14890E1BD678515, uuid:346658E7E26D11DC827BC6338D8CD45D, uuid:63FEA7E3E26B11DC827BC6338D8CD45D, uuid:FA486180E26911DC827BC6338D8CD45D, uuid:F8DD93D3E26711DC827BC6338D8CD45D, uuid:346658E7E26D11DC827BC6338D8CD45D, uuid:AB5762E2E26711DC827BC6338D8CD45D, uuid:AB5762E2E26711DC827BC6338D8CD45D, uuid:E98CBD0AE26B11DC827BC6338D8CD45D, uuid:63FEA7EBE26B11DC827BC6338D8CD45D, adobe:docid:photoshop:438cb972-ce41-11db-b906-885e687027c1, uuid:08328253-029f-11db-8319-000d9345385c Create Date : 2009:04:28 13:42:57+02:00 Modify Date : 2009:04:28 13:43:44+02:00 Metadata Date : 2009:04:28 13:43:44+02:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 7686 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 7 Creator : Adobe InDesign CS3 (5.0.4)EXIF Metadata provided by EXIF.tools