Ge Isovolt Titan E Brochure

Ge-Isovolt-Titan-E-Brochure-648867 ge-isovolt-titan-e-brochure-648867

2015-03-09

: Ge Ge-Isovolt-Titan-E-Brochure-648867 ge-isovolt-titan-e-brochure-648867 ge pdf

Open the PDF directly: View PDF PDF.
Page Count: 7

DownloadGe Ge-Isovolt-Titan-E-Brochure-  Ge-isovolt-titan-e-brochure
Open PDF In BrowserView PDF
GE
Sensing & Inspection Technologies

The ISOVOLT Titan E
X-ray Generator

Robust, Reliable and Highly Accurate Stationary
X-ray Generators for the Widest Range of Applications.
The Reference Class for X-ray generators is based on the proven
ISOVOLT platform, which offers more than 25 years experience with
thousands of installations across the world.

A wide range of systems is provided. Generators and tubes can be
160 kV, 225 kV, 320 kV, 420 kV or 450 kV, and can be operated from
as low as 5 kV or a current range exceeding up to 45 mA*.

Designed for radiography, radioscopy, radiometry and life-science
applications, which place the highest demands on reliability and
exposure quality, the range of Titan E generators and accessories
meets the different degrees of automation and customization,
required throughout the industrial and scientific sectors.

Titan E control is a modern, state-of-the-art industrial control module for
fail-safe and intuitive system operation.
A powerful range of suitable accessories complements the
integration and application capabilities for all facets of industrial or
scientific environments.

Unique Features at a Glance
Highest exposure quality
A reproducibility of ± 0.01 % for tube current (mA) and
tube voltage (kV) provides highest possible stability of
radiation dose rate with fluctuations < 0.05 %.
This excellent dose reproducibility fits both, Titan E applications that
demand the highest accuracy, such as calibration of detectors or
dosimeters, as well as radiography applications.
Extremely low ripple ensures outstandingly stable High Voltage for
optimized material penetration with excellent efficiency factors.
The extended tube range of 5 kV to 450 kV in conjunction with the
excellent maximum current of 45 mA*, ensures optimized imaging
contrast and very high penetration power. This results in short
exposure times in various operation modes for different material.

Highest device availability
Continuous improvements on critical system parameters
to increase robustness and resistance against external
influences, guarantee high system up-times that give
the operator steady revenue streams and perfect time utilization.
Stackable and modular design allows easy field service.
Automatic event recording provide instant information for process
control and system diagnosis either on site or via optional remote
access.

Unmatched ramp-up times (< 1.5 sec) support applications requiring
fast inspection cycles*.
100% duty cycle, for continuous operation in in-line systems**.
Optimized equipment performance results in increased productivity
and reduced total cost of ownership.

Easy to integrate

The stand-alone control module is available in both, a
rugged and ergonomic desktop housing, and also as
19” adapter version, for easy control-desk integration.

The Titan E considers typical OEM needs, providing
kits, interfaces and protocols for all kinds of industrial
system integration (RS 232, Profibus).

The design permits intuitive and fatigue-proof operation through a
large graphical display, rotary knob control, function keys and a
keypad for fast and direct inputs.
The control interacts with the operator in clear text with four
international character sets and 16 languages.

It allows full external control of X-ray equipment and simplifies
remote visualization – even without connecting the control module.
Extension of diagnosis capabilities by remote access via Internet or
dial-up line is available as an option.

Selected tubes feature maintenance-free High voltage connections,
ensuring highest productivity, while minimizing operational risks.
Fully automated tube warm-up procedures safeguard tube
operation and ensure maximum tube life.

Highest device performance
Rugged generator design with intelligent tube
integration and permanent system monitoring, ensure
highest performance, from peaked intermittent, up to
permanent 24/7 operation**. This results in consistent performance
over various exposure modes and operation conditions.

Smart user interaction

Flexible usage

Intelligent and safe operation
Automatic tube configuration in conjunction with real
time clock powered automated warm-up procedures
enhance operational safety and maximize equipment
lifetime.

Built for a wide range of applications in different
environmental conditions, Titan E generator solutions
are for all NDT needs, life science applications and also
measurement and calibration tasks.

On board electronics feature reserved memory for up to 250
programmable operation modes, records of the last 128 warm-up
cycles and 512 operation event-logs and a structured setup menu
for individual performance settings.

Titan E is available in 3-phase, 400 V or single-phase, 230 V input
power rating. As a result easy integration into different power
environments without regional limitations is possible.

Built in safety features such as redundant interlock monitoring,
cooling flow rate watchdog signals, operating temperature and
other system status information are visible on the operation display.
This leads to instant recognition of system status and health.

*) depending on permissable tube data
**) subject to optional generator cooling

2

3

Titan E Control

Benefits

A user-friendly, multi-language control features a clear full-graphical
display, that allows simultaneous readings of set and actual
operating parameters. Embedded in an ergonomic and rugged
desktop or optional 19” rack mounting housing, full control for X-ray
operation is established. Intuitive guidance through diverse menus
as well as unmistakable messages for clear interventions are
provided with this module.

Proven platform serving broad range of applications

The operating concept provides interaction with turning speed
sensitive rotary knob, function keys, a numberic keypad and safety
relevant buttons for X-ray operation as well as a key switch.
The multifunctional rotary knob can be used to set kV, mA, exposure
time and several configuration settings.
By a progressive change of voltage and current via rotary knob
the kV and mA settings can be accurately changed with different
granulations of 0.1kV / 1 kV / 10 kV respectively 0.01 mA (if enabled)
/ 0.1 mA / 1 mA. This allows optimized one-hand operation for
radioscopy and many other applications.

•	 Tube protection due to automatic warm-up procedures and
extended warm-up modes to safeguard tube performance.
•	 Smart and intuitive user interaction, with several integration
possibilities facilitating higher productivity.
•	 Excellent dose reproducability with extremely stable high voltage
section for optimized exposures.
•	 Convenient integration into several external platforms, such
as automated testing machines, leveraging different interface
features for device control, monitoring and visualization.
•	 Excellent endurance and performance for permanent or
intermittent operation.
•	 Less intensive maintenance combined with easier serviceability
reduces total cost of ownership.
•	 Broad range of tubes, accessories and kits available.

Features such as free configurable exposure programmes, or
special programmes for constant power, constant current and
manual operation cater for individual demands for radiographic
or radioscopic inspections. The multi-lingual user display with 16
different languages and extended character sets for Japanese,
Cyrillic and Chinese enables comprehensible and simple interaction.
Optional, the entire system control with graphical visualization can
be done via a stand-alone PC based platform.
Titan E provides automatic and manual warm-up modes for optimized
tube conditioning. A special extended warm-up mode safeguards
tube performance under severe conditions and setups.

4

5

Isovolt
Selection of unipolar Tubes*
ISOVOLT
160 M2
0.4-1.5

ISOVOLT
160 M2
0.4-3.0

ISOVOLT
160 M2
0.4-0.4HP

ISOVOLT
160 MM2/
HP

ISOVOLT
160 MC2

ISOVOLT
160 M1

ISOVOLT
225 M2
0.4-3.0

ISOVOLT
225 M2
0.4-1.5

ISOVOLT
225 MM2/
HP

Max. Tube Voltage (kV)

160

160

160

160

160

160

225

225

225

Tube Current (mA)
(at Max. Tube Voltage)

10
4
1600
640
1.5
0,4
3.00
1.00

19
4
3000
640
3.0
0.4
5.50
1.00

6
6
1000
1000
0.4
0.4
1.00
1.00

11
5
1800
800

6

15,6
5.6
2500
900

0.40 x 4.00

3.00
1.00

7.0
3.0
1600
640
1.5
0.4
3.00
1.00

8
3.5
1800
800

1.00
0.40

13
3.0
3000
640
3.0
0.4
5.50
1.00

Inherent Filtration (mm)

1.0 / Be

1.0 / Be

1.0 / Be

1.0 / Be

1.0 / Be

1.0 / Be

1.0 / Be

1.0 / Be

Emergent Beam Angle

40°

40°

40°

30° x 40°
Asym.

0.5 Ti + 2.0
H20 + 2.0 AI
40° x 360°
Sym.

40°

40°

40°

30° x 40°
Asym.

8.5 (18.7)

8.5 (18.7)

8.5 (18.7)

8.5 (18.7)

8.0 (17.6)

8.5 (18.7)

11.9 (26.2)

11.9 (26.2)

11.9 (26.2)

ISOVOLT
320/7

ISOVOLT
320 M2
4.5 - 13

ISOVOLT
320/13

ISOVOLT
320 M2
0.4 - 1.0 HP

ISOVOLT
420/5

ISOVOLT
450/5

ISOVOLT
450/10

ISOVOLT
450 M2/10

ISOVOLT
450 M2
0.4 - 1.0 HP

Max. Tube Voltage (kV)

320

320

320

320

420

450

450

450

450

Tube Current (mA)
(at Max. Tube Voltage)

7
3
2240
960
1.8
0.8
3.60
1.90

13
4.5
4200
1500
4.0
1.5
5.50
3.00

13
5
4200
1680
3.5
1.5
6.30
3.00

5.6
2.5
1800
800

5
2.1
2240
960
1.5
0.8
3.6
1.90

10
3.7
4500
1680
3.5
1.5
6.30
3.00

10
2
4500
900
3.0
1.2
5.50
2.50

3.3
1.5
1500
700

1.00
0.40

5.3
2.3
2240
960
1.5
0.8
3.60
1.90

Inherent Filtration (mm)

7.0 / Be

3.0 / Be

7.0 / Be

3.0 / Be

7.0 / Be

7.0 / Be

7.0 / Be

5.0 / Be

5.0 / Be

Emergent Beam Angle

20° x 40°

40°

40°

30° x 40°
Asym.

20° x 40°

20° x 40°

40°

40°

30° x 40°
Asym.

40 (88)

40 (88)

40 (88)

40 (88)

90 (198)

90 (198)

90 (198)

90 (198)

90 (198)

Max. Anode Dissipation (W)
Nom. Focal Spot Value IEC 336
Focal Spot Size EN 12 543 (mm)

Weight (kg (lbs))

Accessories
Safety devices
•	 Primary interlock switch

Integration and solution kits
•	 Exposure Calculator (PC Software)

•	 Alarm box
•	 Switch box

•	 Titan E PC (External PC based
visualization)

•	 Flash- and warning lamps

•	 PROFIBUS Extension Kit

•	 Country specific safety kits
HV cables
•	 In different standard lengths, with
quick-lock or flange connections with
rubbercone plugs or maintenance-free
angle plugs.

1000
0.3 x 3

1.00
0.40

Selection of bipolar Tubes*

Dosimetry and calibration kits
•	 Voltage divider (incl. PTB certification)

Max. Anode Dissipation (W)

Pumps and coolers
(See pictures below)

Nom. Focal Spot Value IEC 336
Focal Spot Size EN 12 543 (mm)

Weight (kg (lbs))

1.00
0.40

* The ISOVOLT Titan E series can be equipped with various types of tube housing to suit your application. Ask your GE v
representative for an application specific consultation and a full list of tube housings

WL 3000 SE

6

OW 4002

OL 4503

OLK 50

Voltage Divider

Maintenance free
angle plug

Junction Kits and
Safety Devices

Diaphragms

Column Stand

7

System Layout for Exemplary Setups
Bipolar Operation

Unipolar operation

(1)

(1)

(2)

(4a)

(8a)

(4b)

(4a)

(2)

(3)
(3)

(6a)

(6b)
(5)

(5)

(5)

(5)
(7a)

(1)	 Mains connecting cable, standard length 10 m / 32 ft, with wire
end ferrules

(6a)	 Unipolar Tube Housing
(see tube overview or separate product information)

(2)	 Control Module ISOVOLT Titan E in desktop housing
(optional 19” rack house)

(6b)	 Bipolar Tube Housing
(see tube overview or separate product information)

(3)	 Connecting cable control/power stage, standard length 10 m
(max. 100 m) / 32 ft. (max. approx 320 ft.)

(7a)	 Water hoses, standard length 10 m (max. 20 m) / 16 ft (max. 32 ft)

(4b)	 High Voltage Generator, 160 kV or 225 kV, Anode
incl. Connecting cable

(7b)

Input and output connections

Legend

(4a)	 High Voltage Generator, 160 kV or 225 kV, Cathode,
with integrated power module Titan E

(8b)

(7b)	 Cooling Oil hoses, standard length 6m (max. 20 m) / 19 ft (max.
64 ft)
(8a)	 Water Cooling Pump with built in flow rate monitor,
see separate specification

•	
•	
•	
	
•	
	
•	
•	
•	
•	

RS 232 interface for connection of machine controls
Interlock as per DIN 54113.
Interlock as per United States Radiation Control Act of 1968,
§ 1020.40.
Additional warning output that is active during
pre-warning time.
External START/STOP.
External EMERGENCY-STOP.
Cooling system.
External warning flash lamp (fail-safe).

•	
•	
•	
•	
	
•	
	

“Mains ON” (230V / 2A2).
“High Voltage ON” (230V / 2A2).
Potential-free contact, for “Mains ON” (60V AC / 75V DC / 2A1).
Potential-free contact, for “Pre-warning Time ON”
(30V AC/36V DC / 0.5A1).
Potential-free contact, for “High Voltage ON”
(60V AC / 75V DC / 2A1).

1) This voltage corresponds to the max. operating voltage (rating as per VDE 0110 Group B).
2) These 230 V contacts are collectively fused with 2.5 A.

(8b)	 Oil Cooling Pump, see separate specification

(5)	 High Voltage Cables, 160 kV or 225 kV, standard length
5 m / 16 ft (max. 20 m / 64 ft for 160 kV - 320 kV; max. 10 m / 32 ft
for 420 kV and 450 kV)

8

9

Technical Specifications
Unipolar Systems

Bipolar Systems

High Voltage Generator
Max. Output Voltage
Max. Output Current
Max. Output Power
High Voltage Ripple
Insulation
Housing Dimensions (Cathode) (W x D x H)
Weight (Cathode)

160 kV
45 mA
4,5 kW, Limited by Tube Specification
5 V/mA (With High Voltage Cable 10 m), 40 kHz
Oil
350 x 870 x 850 mm (13.8” x 34.3” x 33.5”)
189 kg (417 lbs), Including Power Module

225 kV
45 mA
4,5 kW, Limited by Tube Specification
5 V/mA (With High Voltage Cable 10 m), 40 kHz
Oil
350 x 870 x 850 mm (13.8” x 34.3” x 33.5”)
189 kg (417 lbs), Including Power Module

Tube Voltage
Preselection and Setting
Digital Display of Set and Actual Values
Display Resolution
Accuracy
Reproducibility
Temperature Drift

From 5 to 160 kV in 0.1 kV / 1 kV / 10 kV
Simultaneous 4 Digits Each
0.1 kV
< ±1%
±0.01% at Constant Temperature Level
< 65 ppm/°C

From 5 to 225 kV in 0.1 kV / 1 kV / 10 kV
Simultaneous 4 Digits Each
0.1 kV
< ±1%
±0.01% at Constant Temperature Level
< 65 ppm/°C

Tube Current
Preselection and Setting
Digital Display of Set and Actual Values
Display Resolution
Accuracy
Reproducibility
Temperature Drift

From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA
Simultaneous 4 Digits Each
0.1 mA / 0.01 mA
± 1%
± 0.01% at Constant Temperature Level
< 65 ppm/°C

From 0.1 to 45 mA in in 0.01 mA / 0.1 mA / 1 mA
Simultaneous 4 Digits Each
0.1 mA / 0.01 mA
±1%
± 0.01% at Constant Temperature Level
< 65 ppm/°C

Non-Volatile Memory
From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
from 1 to 999 Sec. in 1 Sec. Increments or as direct
Min./Sec. value (up to 99’59”)
The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error

Non-Volatile Memory
From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
from 1 to 999 Sec. in 1 Sec. Increments or as direct
Min./Sec. value (up to 99’59”)
The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error

Digital Setting From 2 to 250 Seconds or
de-activated

Digital Setting From 2 to 250 Seconds or
de-activated

Operation History

250
Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
8 Tube selectable from a database of > 40
pre-programmed tubes
512 Events (256 On/Off Events)

250
Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
8 Tube selectable from a database of > 40
pre-programmed tubes
512 Events (256 On/Off Events)

Warm-up History

128 Events

128 Events

460 x 270 x 100 mm (18.1” x 10.6” x 3.9”)
Built into Desk Housing
4.9 kg (10.8 lbs) Including Desk Housing

460 x 270 x 100 mm (18.1” x 10.6” x 3.9”) Built into
Desk Housing
4.9 kg (10.8 lbs) Including Desk Housing

1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)
63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied
0°C to +40°C
-30°C to +70°C

1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)
63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied
0°C to +40°C
-30°C to +70°C

Exposure Time
Programmable Timer
Preselection and Setting
Digital Display of Set and Actual Values
Prewarning Time
Preselection and Setting
Programmed Mode
Number of Storable Programs
Warm-Up
X-ray Tube Setup

Control Module
Dimensions (W x D x H)
Weight
Connected Loads
Power connection

Grounding
Mains Fuses
Operating Temperature Range
Storage Temperature Range

High Voltage Generator
Max. Output Voltage
Max. Output Current
Max. Output Power

Weight (Anode)
Weight (Cathode)

-160 kV (Cathode), +160 kV (Anode)
45 mA
4,5 kW (Cathode)
3 kW (Anode)
Limited by Tube Specification
10 V/mA (With High Voltage Cable 10 m), 40 kHz
Oil
512 Events (256 On / Off events)
128 Events
350 x 870 x 620 mm (13.8” x 34.3” x 24.4”)
350 x 870 x 850 mm (13.8” x 34.3” x 33.5”)
123 kg (272 lbs)
189 kg (417 lbs), Including Power Module

-225 kV (Cathode), +225 kV (Anode)
45 mA
4,5 kW (Cathode)
3 kW (Anode)
Limited by Tube Specification
10 V/mA (With High Voltage Cable 10 m), 40 kHz
Oil
512 Events (256 On / Off events)
128 Events
350 x 870 x 620 mm (13.8” x 34.3” x 24.4”)
350 x 870 x 850 mm (13.8” x 34.3” x 33.5”)
123 kg (272 lbs)
189 kg (417 lbs), Including Power Module

Tube Voltage (Anode)
Preselection and Setting
Digital Display of Set and Actual Values
Display Resolution
Accuracy
Reproducibility
Temperature Drift

From 5 to 320 kV in 0.1 kV / 1 kV / 10 kV
Simultaneous 4 Digits Each
0.1 kV
< ±1%
±0.01% at Constant Temperature Level
< 65 ppm/°C

From 5 to 450 kV in 0.1 kV / 1 kV / 10 kV
Simultaneous 4 Digits Each
0.1 kV
< ±1%
±0.01% at Constant Temperature Level
< 65 ppm/°C

Tube Current
Preselection and Setting
Digital Display of Set and Actual Values
Display Resolution
Accuracy
Reproducibility
Temperature Drift

From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA
Simultaneous 4 Digits Each
0.1 mA / 0.01 mA
± 1%
± 0.01% at Constant Temperature Level
< 65 ppm/°C

From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA
Simultaneous 4 Digits Each
0.1 mA / 0.01 mA
±1%
± 0.01% at Constant Temperature Level
< 65 ppm/°C

Non-Volatile Memory
From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
From 1 to 999 Sec. in 1 Sec. Increments or as
direct Min./Sec. value (up to 99’59”)
The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error

Non-Volatile Memory
From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
From 1 to 999 Sec. in 1 Sec. Increments or as
direct Min./Sec. value (up to 99’59”)
The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error

Digital Setting From 2 to 250 Seconds or
de-activated

Digital Setting From 2 to 250 Seconds or
de-activated

250
Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
8 Tube selectable from a database of > 40
pre-programmed tubes

250
Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
8 Tube selectable from a database of > 40
pre-programmed tubes

460 x 270 x 100 mm (18.1” x 10.6” x 3.9”)
Built into Desk Housing
4.9 kg (10.8 lbs) Including Desk Housing

460 x 270 x 100 mm (18.1” x 10.6” x 3.9”)
Built into Desk Housing
4.9 kg (10.8 lbs) Including Desk Housing

1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)
63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied
0°C to +40°C
-30°C to +70°C

1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)
63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied
0°C to +40°C
-30°C to +70°C

High Voltage Ripple
Insulation
Operation History
Warm-up History
Housing Dimensions (Cathode) (W x D x H)

Exposure Time
Programmable Timer
Preselection and Setting
Digital Display of Set and Actual Values
Prewarning Time
Preselection and Setting
Programmed Mode
Number of Storable Programs
Warm-Up
X-ray Tube Setup
Control Module
Dimensions (W x D x H)
Weight
Connected Loads
Power connection

Grounding
Mains Fuses
Operating Temperature Range
Storage Temperature Range

10

11

Regional Contact Information
GE Sensing & Inspection Technologies
Bogenstrasse 41
22926 Ahrensburg
Germany
+49 4102 8070
GE Sensing & Inspection Technologies
50 Industrial Park Road
Lewistown, PA 17044
USA
+1 717 242 0327
GE Sensing & Inspection Technologies
Robert Bosch Strasse 3
50354 Huerth
Germany
+49 2233 6010
GE Sensing & Inspection Technologies
5F, Hongcao Building
421 Hongcao Road
Shanghai 200233
China
+86 800 820 1876 (China toll free)
+86 21 3414 4620 (ext. 6029)

www.gesensinginspection.com
GEIT-30167EN(05/09)
© 2009 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names
mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56
Instance ID                     : uuid:a77429e1-3ea2-4a18-be65-513303dd4c79
Document ID                     : adobe:docid:indd:dc7f9da0-16b8-11dd-9b72-b617b0ce9091
Rendition Class                 : proof:pdf
Derived From Instance ID        : dc7f9d9f-16b8-11dd-9b72-b617b0ce9091
Derived From Document ID        : adobe:docid:indd:786a8896-f0f2-11dc-94a7-84d0c46f6dfc
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 75.00, 72.00, 300.00, 300.00, 75.00, 300.00, 300.00, 75.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 75.00, 72.00, 300.00, 300.00, 75.00, 300.00, 300.00, 75.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:7C50DCD3F05311DC8FCBBC6C93B6AB24, uuid:82b4576a-70df-415d-bdc7-4d3c4251e0d1, uuid:4F342ED0CC1111DCB3E2FED19896479A, uuid:60A3652DCC1111DCB3E2FED19896479A, uuid:20B33E3CCC1111DCB3E2FED19896479A, uuid:323E1072CC1211DCB3E2FED19896479A, uuid:CBA806FF7A4811DC8953C29FB14FD13D, uuid:2E273238CC1111DCB3E2FED19896479A, uuid:8C2C4CC2CC1111DCB3E2FED19896479A, uuid:CBA806FF7A4811DC8953C29FB14FD13D, uuid:4F342ED0CC1111DCB3E2FED19896479A, uuid:60A3652DCC1111DCB3E2FED19896479A, uuid:2E273238CC1111DCB3E2FED19896479A, uuid:323E1072CC1211DCB3E2FED19896479A, uuid:20B33E3CCC1111DCB3E2FED19896479A, uuid:8C2C4CC2CC1111DCB3E2FED19896479A, uuid:8E7F9B8BF0F411DCA14890E1BD678515, uuid:E45138B3F0F911DCA14890E1BD678515, uuid:F704B8EFF75911DC8C79F99889A0F0A1, uuid:B93992C3F0F711DCA14890E1BD678515, uuid:B784745CF75C11DC8C79F99889A0F0A1, uuid:34F22C55CB4911DCB3E2FED19896479A, uuid:9F49795716BB11DDAFBE808894E0F13C, uuid:B423F6E7F0DC11DC8756CB1939EBA4E9, uuid:CE4A6CD6F11011DCA77C9B4E16D73E38, uuid:E32850FCF74E11DC8C79F99889A0F0A1, uuid:D8D04491F10311DCA14890E1BD678515, uuid:42E45FEAF10211DCA14890E1BD678515, uuid:9E44A64CF10111DCA14890E1BD678515, uuid:FB72D418F10011DCA14890E1BD678515, uuid:9BF6EC72F74F11DC8C79F99889A0F0A1, uuid:2AEAD009F0FA11DCA14890E1BD678515, uuid:33C8BB51F10B11DCA77C9B4E16D73E38, uuid:8FE8C7ECF8E111DC8509A6B07552B1F8, uuid:5114AF1716B111DDAFBE808894E0F13C, uuid:4FF3CE57F10B11DCA77C9B4E16D73E38, uuid:346658E8E26D11DC827BC6338D8CD45D, uuid:21302C78F75011DC8C79F99889A0F0A1, uuid:3D5A0944E26C11DC827BC6338D8CD45D, uuid:F8DD93D4E26711DC827BC6338D8CD45D, uuid:346658E8E26D11DC827BC6338D8CD45D, uuid:2C8FF9DDF10D11DCA77C9B4E16D73E38, uuid:2C8FF9DDF10D11DCA77C9B4E16D73E38, uuid:3D5A093DE26C11DC827BC6338D8CD45D, uuid:17240556F10D11DCA77C9B4E16D73E38, uuid:438cb973-ce41-11db-b906-885e687027c1, uuid:6cddbe45-0df5-11dc-a335-000d9345385c
Manifest Reference Document ID  : uuid:3BB610E6F05311DC8FCBBC6C93B6AB24, uuid:08328253-029f-11db-8319-000d9345385c, uuid:4F342ECFCC1111DCB3E2FED19896479A, uuid:60A3652CCC1111DCB3E2FED19896479A, uuid:F9DB37CECC1011DCB3E2FED19896479A, uuid:849BB7DACC1111DCB3E2FED19896479A, uuid:CBA806FE7A4811DC8953C29FB14FD13D, uuid:2E273237CC1111DCB3E2FED19896479A, uuid:8C2C4CC1CC1111DCB3E2FED19896479A, uuid:CBA806FE7A4811DC8953C29FB14FD13D, uuid:4F342ECFCC1111DCB3E2FED19896479A, uuid:60A3652CCC1111DCB3E2FED19896479A, uuid:2E273237CC1111DCB3E2FED19896479A, uuid:849BB7DACC1111DCB3E2FED19896479A, uuid:F9DB37CECC1011DCB3E2FED19896479A, uuid:8C2C4CC1CC1111DCB3E2FED19896479A, uuid:8E7F9B8AF0F411DCA14890E1BD678515, uuid:05BB3BC3F0F811DCA14890E1BD678515, uuid:37C6B280F75311DC8C79F99889A0F0A1, uuid:F7488089F0F611DCA14890E1BD678515, uuid:B7847454F75C11DC8C79F99889A0F0A1, uuid:ED208796CA6011DCB3E2FED19896479A, uuid:2BFD9B18F11611DCA77C9B4E16D73E38, uuid:B423F6E6F0DC11DC8756CB1939EBA4E9, uuid:CE4A6CD5F11011DCA77C9B4E16D73E38, uuid:E32850F2F74E11DC8C79F99889A0F0A1, uuid:42E45FF2F10211DCA14890E1BD678515, uuid:13DF71C4F0E811DCA14890E1BD678515, uuid:07D6641DF0E811DCA14890E1BD678515, uuid:2D2DFF0EF0E811DCA14890E1BD678515, uuid:EDA354D0F74E11DC8C79F99889A0F0A1, uuid:F7B52A70F0E711DCA14890E1BD678515, adobe:docid:photoshop:86a0fe2e-e7b8-11dc-8d15-b8facd193f94, uuid:9ADBE0CBF10611DCA14890E1BD678515, uuid:ABCF6BEDF74F11DC8C79F99889A0F0A1, uuid:F6F3DE33F10611DCA14890E1BD678515, uuid:346658E7E26D11DC827BC6338D8CD45D, uuid:63FEA7E3E26B11DC827BC6338D8CD45D, uuid:FA486180E26911DC827BC6338D8CD45D, uuid:F8DD93D3E26711DC827BC6338D8CD45D, uuid:346658E7E26D11DC827BC6338D8CD45D, uuid:AB5762E2E26711DC827BC6338D8CD45D, uuid:AB5762E2E26711DC827BC6338D8CD45D, uuid:E98CBD0AE26B11DC827BC6338D8CD45D, uuid:63FEA7EBE26B11DC827BC6338D8CD45D, adobe:docid:photoshop:438cb972-ce41-11db-b906-885e687027c1, uuid:08328253-029f-11db-8319-000d9345385c
Create Date                     : 2009:04:28 13:42:57+02:00
Modify Date                     : 2009:04:28 13:43:44+02:00
Metadata Date                   : 2009:04:28 13:43:44+02:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 7686 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 7
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu