The ISOVOLT Titan E
X-ray Generator
GE
Sensing & Inspection Technologies
Robust, Reliable and Highly Accurate Stationary
X-ray Generators for the Widest Range of Applications.
The Reference Class for X-ray generators is based on the proven
ISOVOLT platform, which offers more than 25 years experience with
thousands of installations across the world.
Designed for radiography, radioscopy, radiometry and life-science
applications, which place the highest demands on reliability and
exposure quality, the range of Titan E generators and accessories
meets the different degrees of automation and customization,
required throughout the industrial and scientific sectors.
A wide range of systems is provided. Generators and tubes can be
160 kV, 225 kV, 320 kV, 420 kV or 450 kV, and can be operated from
as low as 5 kV or a current range exceeding up to 45 mA*.
Titan E control is a modern, state-of-the-art industrial control module for
fail-safe and intuitive system operation.
A powerful range of suitable accessories complements the
integration and application capabilities for all facets of industrial or
scientific environments.
*) depending on permissable tube data
**) subject to optional generator cooling
Highest device availability
Continuous improvements on critical system parameters
to increase robustness and resistance against external
influences, guarantee high system up-times that give
the operator steady revenue streams and perfect time utilization.
Stackable and modular design allows easy field service.
Automatic event recording provide instant information for process
control and system diagnosis either on site or via optional remote
access.
Selected tubes feature maintenance-free High voltage connections,
ensuring highest productivity, while minimizing operational risks.
Fully automated tube warm-up procedures safeguard tube
operation and ensure maximum tube life.
Flexible usage
Built for a wide range of applications in different
environmental conditions, Titan E generator solutions
are for all NDT needs, life science applications and also
measurement and calibration tasks.
Titan E is available in 3-phase, 400 V or single-phase, 230 V input
power rating. As a result easy integration into different power
environments without regional limitations is possible.
Unique Features at a Glance
Highest exposure quality
A reproducibility of ± 0.01 % for tube current (mA) and
tube voltage (kV) provides highest possible stability of
radiation dose rate with fluctuations < 0.05 %.
This excellent dose reproducibility fits both, Titan E applications that
demand the highest accuracy, such as calibration of detectors or
dosimeters, as well as radiography applications.
Extremely low ripple ensures outstandingly stable High Voltage for
optimized material penetration with excellent efficiency factors.
The extended tube range of 5 kV to 450 kV in conjunction with the
excellent maximum current of 45 mA*, ensures optimized imaging
contrast and very high penetration power. This results in short
exposure times in various operation modes for different material.
Highest device performance
Rugged generator design with intelligent tube
integration and permanent system monitoring, ensure
highest performance, from peaked intermittent, up to
permanent 24/7 operation**. This results in consistent performance
over various exposure modes and operation conditions.
Unmatched ramp-up times (< 1.5 sec) support applications requiring
fast inspection cycles*.
100% duty cycle, for continuous operation in in-line systems**.
Optimized equipment performance results in increased productivity
and reduced total cost of ownership.
Smart user interaction
The stand-alone control module is available in both, a
rugged and ergonomic desktop housing, and also as
19” adapter version, for easy control-desk integration.
The design permits intuitive and fatigue-proof operation through a
large graphical display, rotary knob control, function keys and a
keypad for fast and direct inputs.
The control interacts with the operator in clear text with four
international character sets and 16 languages.
Intelligent and safe operation
Automatic tube configuration in conjunction with real
time clock powered automated warm-up procedures
enhance operational safety and maximize equipment
lifetime.
On board electronics feature reserved memory for up to 250
programmable operation modes, records of the last 128 warm-up
cycles and 512 operation event-logs and a structured setup menu
for individual performance settings.
Built in safety features such as redundant interlock monitoring,
cooling flow rate watchdog signals, operating temperature and
other system status information are visible on the operation display.
This leads to instant recognition of system status and health.
32
Easy to integrate
The Titan E considers typical OEM needs, providing
kits, interfaces and protocols for all kinds of industrial
system integration (RS 232, Profibus).
It allows full external control of X-ray equipment and simplifies
remote visualization – even without connecting the control module.
Extension of diagnosis capabilities by remote access via Internet or
dial-up line is available as an option.
Titan E Control
A user-friendly, multi-language control features a clear full-graphical
display, that allows simultaneous readings of set and actual
operating parameters. Embedded in an ergonomic and rugged
desktop or optional 19” rack mounting housing, full control for X-ray
operation is established. Intuitive guidance through diverse menus
as well as unmistakable messages for clear interventions are
provided with this module.
The operating concept provides interaction with turning speed
sensitive rotary knob, function keys, a numberic keypad and safety
relevant buttons for X-ray operation as well as a key switch.
The multifunctional rotary knob can be used to set kV, mA, exposure
time and several configuration settings.
By a progressive change of voltage and current via rotary knob
the kV and mA settings can be accurately changed with different
granulations of 0.1kV / 1 kV / 10 kV respectively 0.01 mA (if enabled)
/ 0.1 mA / 1 mA. This allows optimized one-hand operation for
radioscopy and many other applications.
Features such as free configurable exposure programmes, or
special programmes for constant power, constant current and
manual operation cater for individual demands for radiographic
or radioscopic inspections. The multi-lingual user display with 16
different languages and extended character sets for Japanese,
Cyrillic and Chinese enables comprehensible and simple interaction.
Optional, the entire system control with graphical visualization can
be done via a stand-alone PC based platform.
Titan E provides automatic and manual warm-up modes for optimized
tube conditioning. A special extended warm-up mode safeguards
tube performance under severe conditions and setups.
Benefits
Proven platform serving broad range of applications
• Tubeprotectionduetoautomaticwarm-upproceduresand
extended warm-up modes to safeguard tube performance.
• Smartandintuitiveuserinteraction,withseveralintegration
possibilities facilitating higher productivity.
• Excellentdosereproducabilitywithextremelystablehighvoltage
section for optimized exposures.
• Convenientintegrationintoseveralexternalplatforms,such
as automated testing machines, leveraging different interface
features for device control, monitoring and visualization.
• Excellentenduranceandperformanceforpermanentor
intermittent operation.
• Lessintensivemaintenancecombinedwitheasierserviceability
reduces total cost of ownership.
• Broadrangeoftubes,accessoriesandkitsavailable.
54
ISOVOLT
WL 3000 SE OW 4002 OL 4503 OLK 50 Voltage Divider
Maintenance free
angle plug
Junction Kits and
Safety Devices
Diaphragms Column Stand
Selection of unipolar Tubes*
ISOVOLT
160 M2
0.4-1.5
ISOVOLT
160 M2
0.4-3.0
ISOVOLT
160 M2
0.4-0.4HP
ISOVOLT
160 MM2/
HP
ISOVOLT
160 MC2 ISOVOLT
160 M1 ISOVOLT
225 M2
0.4-3.0
ISOVOLT
225 M2
0.4-1.5
ISOVOLT
225 MM2/
HP
Max. Tube Voltage (kV) 160 160 160 160 160 160 225 225 225
Tube Current (mA)
(at Max. Tube Voltage)
10 19 611 615,6 13 7.0 8
4465 5.6 3.0 3.0 3.5
Max. Anode Dissipation (W) 1600 3000 1000 1800 1000 2500 3000 1600 1800
640 640 1000 800 900 640 640 800
Nom. Focal Spot Value IEC 336 1.5 3.0 0.4
0.3 x 3
3.0 1.5
0,4 0.4 0.4 0.4 0.4
Focal Spot Size EN 12 543 (mm) 3.00 5.50 1.00 1.00
0.40 x 4.00
3.00 5.50 3.00 1.00
1.00 1.00 1.00 0.40 1.00 1.00 1.00 0.40
Inherent Filtration (mm) 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be 0.5 Ti + 2.0
H20 + 2.0 AI 1.0 / Be 1.0 / Be 1.0 / Be 1.0 / Be
Emergent Beam Angle 40° 40° 40° 30° x 4
Asym. 40° x 360°
Sym. 40° 40° 40° 30° x 40°
Asym.
Weight (kg (lbs)) 8.5 (18.7) 8.5 (18.7) 8.5 (18.7) 8.5 (18.7) 8.0 (17.6) 8.5 (18.7) 11.9 (26.2) 11.9 (26.2) 11.9 (26.2)
* The ISOVOLT Titan E series can be equipped with various types of tube housing to suit your application. Ask your GE v
representative for an application specific consultation and a full list of tube housings
Selection of bipolar Tubes*
ISOVOLT
320/7 ISOVOLT
320 M2
4.5 - 13
ISOVOLT
320/13 ISOVOLT
320 M2
0.4 - 1.0 HP
ISOVOLT
420/5 ISOVOLT
450/5 ISOVOLT
450/10 ISOVOLT
450 M2/10 ISOVOLT
450 M2
0.4 - 1.0 HP
Max. Tube Voltage (kV) 320 320 320 320 420 450 450 450 450
Tube Current (mA)
(at Max. Tube Voltage)
713 13 5.6 5.3 510 10 3.3
34.5 52.5 2.3 2.1 3.7 21.5
Max. Anode Dissipation (W) 2240 4200 4200 1800 2240 2240 4500 4500 1500
960 1500 1680 800 960 960 1680 900 700
Nom. Focal Spot Value IEC 336 1.8 4.0 3.5 1.5 1.5 3.5 3.0
0.8 1.5 1.5 0.8 0.8 1.5 1.2
Focal Spot Size EN 12 543 (mm) 3.60 5.50 6.30 1.00 3.60 3.6 6.30 5.50 1.00
1.90 3.00 3.00 0.40 1.90 1.90 3.00 2.50 0.40
Inherent Filtration (mm) 7.0 / Be 3.0 / Be 7.0 / Be 3.0 / Be 7.0 / Be 7.0 / Be 7.0 / Be 5.0 / Be 5.0 / Be
Emergent Beam Angle 20° x 4 40° 40° 30° x 4
Asym. 20° x 40° 20° x 40° 40° 40° 30° x 40°
Asym.
Weight (kg (lbs)) 40 (88) 40 (88) 40 (88) 40 (88) 90 (198) 90 (198) 90 (198) 90 (198) 90 (198)
Accessories
Safety devices
• Primaryinterlockswitch
• Alarmbox
• Switchbox
• Flash-andwarninglamps
• Countryspecicsafetykits
HV cables
• Indifferentstandardlengths,with
quick-lock or flange connections with
rubbercone plugs or maintenance-free
angle plugs.
Integration and solution kits
• ExposureCalculator(PCSoftware)
• Titan E PC (External PC based
visualization)
• PROFIBUSExtensionKit
Dosimetry and calibration kits
• Voltagedivider(incl.PTBcertication)
Pumps and coolers
(See pictures below)
76
System Layout for Exemplary Setups
Unipolar operation Bipolar Operation
Legend
(1) Mains connecting cable, standard length 10 m / 32 ft, with wire
end ferrules
(2) Control Module ISOVOLT Titan E in desktop housing
(optional 19” rack house)
(3) Connecting cable control/power stage, standard length 10 m
(max. 100 m) / 32 ft. (max. approx 320 ft.)
(4a) High Voltage Generator, 160 kV or 225 kV, Cathode,
with integrated power module TITAN E
(4b) High Voltage Generator, 160 kV or 225 kV, Anode
incl. Connecting cable
(5) High Voltage Cables, 160 kV or 225 kV, standard length
5 m / 16 ft (max. 20 m / 64 ft for 160 kV - 320 kV; max. 10 m / 32 ft
for 420 kV and 450 kV)
Input and output connections
• RS232interfaceforconnectionofmachinecontrols
• InterlockasperDIN54113.
• InterlockasperUnitedStatesRadiationControlActof1968,
§ 1020.40.
• Additionalwarningoutputthatisactiveduring
pre-warning time.
• ExternalSTART/STOP.
• ExternalEMERGENCY-STOP.
• Coolingsystem.
• Externalwarningashlamp(fail-safe).
(5)
(2) (1)
(3)
(4a)
(7a)
(6a)
(8a)
(5)
(6b)
(5)
(5)
(2)
(3)
(7b)
(8b)
(1)
(4a) (4b)
(6a) Unipolar Tube Housing
(see tube overview or separate product information)
(6b) Bipolar Tube Housing
(see tube overview or separate product information)
(7a)
Water hoses, standard length 10 m (max. 20 m) / 16 ft (max. 32 ft)
(7b) Cooling Oil hoses, standard length 6m (max. 20 m) / 19 ft (max.
64 ft)
(8a) Water Cooling Pump with built in flow rate monitor,
see separate specification
(8b) Oil Cooling Pump, see separate specification
• “MainsON”(230V/2A2).
• “HighVoltageON”(230V/2A2).
• Potential-freecontact,for“MainsON”(60VAC/75VDC/2A1).
• Potential-freecontact,for“Pre-warningTimeON”
(30V AC/36V DC / 0.5A1).
• Potential-freecontact,for“HighVoltageON”
(60V AC / 75V DC / 2A1).
1) This voltage corresponds to the max. operating voltage (rating as per VDE 0110 Group B).
2) These 230 V contacts are collectively fused with 2.5 A.
98
Technical Specifications
Unipolar Systems
High Voltage Generator
Max. Output Voltage 160 kV 225 kV
Max. Output Current 45 mA 45 mA
Max. Output Power 4,5 kW, Limited by Tube Specification 4,5 kW, Limited by Tube Specification
High Voltage Ripple 5 V/mA (With High Voltage Cable 10 m), 40 kHz 5 V/mA (With High Voltage Cable 10 m), 40 kHz
Insulation Oil Oil
Housing Dimensions (Cathode) (W x D x H) 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”) 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”)
Weight (Cathode) 189 kg (417 lbs), Including Power Module 189 kg (417 lbs), Including Power Module
Tube Voltage
Preselection and Setting From 5 to 160 kV in 0.1 kV / 1 kV / 10 kV From 5 to 225 kV in 0.1 kV / 1 kV / 10 kV
Digital Display of Set and Actual Values Simultaneous 4 Digits Each Simultaneous 4 Digits Each
Display Resolution 0.1 kV 0.1 kV
Accuracy < ±1% < ±1%
Reproducibility ±0.01% at Constant Temperature Level ±0.01% at Constant Temperature Level
Temperature Drift < 65 ppm/°C < 65 ppm/°C
Tube Current
Preselection and Setting From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA From 0.1 to 45 mA in in 0.01 mA / 0.1 mA / 1 mA
Digital Display of Set and Actual Values Simultaneous 4 Digits Each Simultaneous 4 Digits Each
Display Resolution 0.1 mA / 0.01 mA 0.1 mA / 0.01 mA
Accuracy ± 1% ±1%
Reproducibility ± 0.01% at Constant Temperature Level ± 0.01% at Constant Temperature Level
Temperature Drift < 65 ppm/°C < 65 ppm/°C
Exposure Time
Programmable Timer Non-Volatile Memory Non-Volatile Memory
Preselection and Setting From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
from 1 to 999 Sec. in 1 Sec. Increments or as direct
Min./Sec. value (up to 99’59”)
From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
from 1 to 999 Sec. in 1 Sec. Increments or as direct
Min./Sec. value (up to 99’59”)
Digital Display of Set and Actual Values The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error
The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error
Prewarning Time
Preselection and Setting Digital Setting From 2 to 250 Seconds or
de-activated Digital Setting From 2 to 250 Seconds or
de-activated
Programmed Mode
Number of Storable Programs 250 250
Warm-Up Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
X-ray Tube Setup 8 Tube selectable from a database of > 40
pre-programmed tubes 8 Tube selectable from a database of > 40
pre-programmed tubes
Operation History 512 Events (256 On/Off Events) 512 Events (256 On/Off Events)
Warm-up History 128 Events 128 Events
Control Module
Dimensions (W x D x H) 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”)
Built into Desk Housing 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”) Built into
Desk Housing
Weight 4.9 kg (10.8 lbs) Including Desk Housing 4.9 kg (10.8 lbs) Including Desk Housing
Connected Loads
Power connection 1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
Grounding Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)
Mains Fuses 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied
Operating Temperature Range C to +40°C C to +40°C
Storage Temperature Range -30°C to +70°C -30°C to +70°C
Bipolar Systems
High Voltage Generator
Max. Output Voltage -160 kV (Cathode), +160 kV (Anode) -225 kV (Cathode), +225 kV (Anode)
Max. Output Current 45 mA 45 mA
Max. Output Power 4,5 kW (Cathode)
3 kW (Anode)
Limited by Tube Specification
4,5 kW (Cathode)
3 kW (Anode)
Limited by Tube Specification
High Voltage Ripple 10 V/mA (With High Voltage Cable 10 m), 40 kHz 10 V/mA (With High Voltage Cable 10 m), 40 kHz
Insulation Oil Oil
Operation History 512 Events (256 On / Off events) 512 Events (256 On / Off events)
Warm-up History 128 Events 128 Events
Housing Dimensions (Cathode) (W x D x H) 350 x 870 x 620 mm (13.8” x 34.3” x 24.4”) 350 x 870 x 620 mm (13.8” x 34.3” x 24.4”)
350 x 870 x 850 mm (13.8” x 34.3” x 33.5”) 350 x 870 x 850 mm (13.8” x 34.3” x 33.5”)
Weight (Anode) 123 kg (272 lbs) 123 kg (272 lbs)
Weight (Cathode) 189 kg (417 lbs), Including Power Module 189 kg (417 lbs), Including Power Module
Tube Voltage (Anode)
Preselection and Setting From 5 to 320 kV in 0.1 kV / 1 kV / 10 kV From 5 to 450 kV in 0.1 kV / 1 kV / 10 kV
Digital Display of Set and Actual Values Simultaneous 4 Digits Each Simultaneous 4 Digits Each
Display Resolution 0.1 kV 0.1 kV
Accuracy < ±1% < ±1%
Reproducibility ±0.01% at Constant Temperature Level ±0.01% at Constant Temperature Level
Temperature Drift < 65 ppm/°C < 65 ppm/°C
Tube Current
Preselection and Setting From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA From 0.1 to 45 mA in 0.01 mA / 0.1 mA / 1 mA
Digital Display of Set and Actual Values Simultaneous 4 Digits Each Simultaneous 4 Digits Each
Display Resolution 0.1 mA / 0.01 mA 0.1 mA / 0.01 mA
Accuracy ± 1% ±1%
Reproducibility ± 0.01% at Constant Temperature Level ± 0.01% at Constant Temperature Level
Temperature Drift < 65 ppm/°C < 65 ppm/°C
Exposure Time
Programmable Timer Non-Volatile Memory Non-Volatile Memory
Preselection and Setting From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
From 1 to 999 Sec. in 1 Sec. Increments or as
direct Min./Sec. value (up to 99’59”)
From 0.1 to 99.9 Minutes in 0.1 Min. Increments or
From 1 to 999 Sec. in 1 Sec. Increments or as
direct Min./Sec. value (up to 99’59”)
Digital Display of Set and Actual Values The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error
The Remaining Time Is Displayed, i.e. After a Mains
Failure Exposure Can Be Continued Without any
Time Error
Prewarning Time
Preselection and Setting Digital Setting From 2 to 250 Seconds or
de-activated Digital Setting From 2 to 250 Seconds or
de-activated
Programmed Mode
Number of Storable Programs 250 250
Warm-Up Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
Automatic Intelligent Tube conditioning based on
Real-time Clock
Extended warm-up for special conditioning
X-ray Tube Setup 8 Tube selectable from a database of > 40
pre-programmed tubes 8 Tube selectable from a database of > 40
pre-programmed tubes
Control Module
Dimensions (W x D x H) 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”)
Built into Desk Housing 460 x 270 x 100 mm (18.1” x 10.6” x 3.9”)
Built into Desk Housing
Weight 4.9 kg (10.8 lbs) Including Desk Housing 4.9 kg (10.8 lbs) Including Desk Housing
Connected Loads
Power connection 1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
1N PE 230 V ± 10% 50/60 Hz
3N PE 400/230 V ±10%, 50/60 Hz, 3-Phase,
Grounded Neutral TN-S or TN-C-S Mains (Star
Connected System, Optional 3-Phase Isolation
Transformer)
Grounding Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)Separate Grounding for X-ray Tube and High
Voltage Generator (Minimum 6 mm2)
Mains Fuses 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied 63 A (1N PE) or 25 A (3N PE) Time-Delay Fuses,
Customer-Supplied
Operating Temperature Range 0°C to +40°C C to +40°C
Storage Temperature Range -30°C to +70°C -30°C to +70°C
1110
Regional Contact Information
GE Sensing & Inspection Technologies
Bogenstrasse 41
22926 Ahrensburg
Germany
+49 4102 8070
GE Sensing & Inspection Technologies
50 Industrial Park Road
Lewistown, PA 17044
USA
+1 717 242 0327
GE Sensing & Inspection Technologies
Robert Bosch Strasse 3
50354 Huerth
Germany
+49 2233 6010
GE Sensing & Inspection Technologies
5F, Hongcao Building
421 Hongcao Road
Shanghai 200233
China
+86 800 820 1876 (China toll free)
+86 21 3414 4620 (ext. 6029)
© 2009 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names