g FLOOD LIGHTING GE Lighting Solutions GUIDE FORM SPECIFICATIONS PF-400 ® POWERFLOOD ® floodlight GENERAL DESCRIPTION The NEMA heavy-duty weather-resistant floodlight designated _______ (identify) shall be a GE PF-400® POWERFLOOD® floodlight, ordering number _______ (specify PF4S, PF4T, plus ordering number logic from catalog) or approved equal, for operation of one _______ (specify [150(55V), 200, 250, or 400] watt high pressure sodium [HPS], [175, 250 or 400] watt metal halide or 400 watt mercury) lamp from a nominal _______ (specify 120, 208, 220, 240, 277, 347 or 480 volt, 60 Hz or 220, 230 or 240 volt, 50 Hz) power source and shall be capable of starting and operating the specified lamp within the limits specified by the lamp manufacturer. The floodlight shall contain a completely prewired integral ballast and optical assembly with _______ (specify 3X2, 4X2, 4X4, 5X4, 6X4, 6X5, 6X6, 7X6 or 7X7 according to photometric selection table in the catalog) NEMA type beam spread (horizontal X vertical). The floodlight shall have a NEMA lamp identification decal. The floodlight shall be UL/cUL Listed SUITABLE FOR WET LOCATIONS. Standard construction is IP55. Ballast, housing, optical and luminaire assembly shall all be from the same manufacturer. MECHANICAL CONSTRUCTION The floodlight shall include die-cast aluminum housing with hinged and removable front-access door having captive screw (or optional wire bail latches), ballast, filtered optical assembly, _______ (specify steel trunnion [standard], die-cast aluminum knuckle slipfitter or knuckle wall mount with integral wiring box and vertical aiming degree markings) (and optional photoelectric control receptacle). All hardware shall be corrosionresistant. All die-cast aluminum surfaces shall have a _______ (specify dark bronze [standard] or gray) electrocoat paint finish. The floodlight shall have a built-in aiming sight. BALLAST OPERATION OPTICAL ASSEMBLY The optical assembly shall be sealed with a gasket around the perimeter of the front access door, contain an activated charcoal filter and include a formed aluminum reflector and heat/impact-resistant flat door glass. The reflector shall have a chemically-bonded lightweight nonbreakable glass ALGLAS ® finish on both the inside and outside surfaces providing enhanced specular reflectance, corrosion resistance, durability and ease of cleaning. The optical assembly shall contain an E39 mogul base socket with superior lamp gripping. The socket shall have added insulation, giving it the ability to handle the higher pulse ratings of newer HID systems. Lamp shall be mounted _______ (specify horizontally or vertically). * REFER TO PRODUCT PAGE FOR OTHER BALLAST SELECTIONS. FOR MORE DEFINITIVE INFORMATION, REFER TO BALLAST SPECIFICATIONS IN TECHNICAL DATA SECTION. The ballast shall be prewired to the lamp socket and terminal board and there shall be a plug-in type starter aid for high pressure sodium fixtures. (For convenience of installation and maintenance, an optional tray mount for ballast and other electrical components is available [for use with HPS lamps only].) The floodlight shall contain a _______ (specify standard Autoreg or Mag-Reg.) type ballast* in full compliance with lampballast specifications available to the fixture manufacturer from the lamp manufacturers at the time of fixture manufacture. As an option the ballast may have the capability of operating high pressure sodium or metal halide lamp at any of four voltages — 120, 208, 240 or 277 volts. When specified, the multiwatt ballast (250/400) shall be connected for 250 watts unless otherwise specified. Check the Ballast and Photometric Selection Table before selecting a special rating. The ballast shall reliably start and operate the lamp in ambient temperatures down to -20°F for mercury or metal halide or -40°F for HPS. Guide Form Specifications – 2011 g GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com 1-88 8 - 6 9 - 4 3-5 3 3 GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company. © 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : GE Outdoor Floodlighting Create Date : 2010:11:24 07:48:12-05:00 Keywords : Outdoor lighting, ge lighting, Floodlighting, PF400 Powerflood, Spec Sheet.. Modify Date : 2013:10:02 15:35:46-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2013:10:02 15:35:46-04:00 Creator Tool : Adobe InDesign CS4 (6.0.6) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11566 bytes, use -b option to extract) Instance ID : uuid:e2299944-8917-4d09-8f71-2babc1f0b3b6 Document ID : xmp.did:69647F321DF7DF11A86EE099FD0A2EDA Original Document ID : xmp.did:69647F321DF7DF11A86EE099FD0A2EDA Rendition Class : proof:pdf History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:69647F321DF7DF11A86EE099FD0A2EDA, xmp.iid:7186D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7286D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7386D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7586D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7686D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7786D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7886D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7986D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7A86D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:7B86D75D1FF7DF11A86EE099FD0A2EDA, xmp.iid:8BECB83421F7DF11A86EE099FD0A2EDA, xmp.iid:8CECB83421F7DF11A86EE099FD0A2EDA, xmp.iid:8DECB83421F7DF11A86EE099FD0A2EDA, xmp.iid:8EECB83421F7DF11A86EE099FD0A2EDA, xmp.iid:94ECB83421F7DF11A86EE099FD0A2EDA, xmp.iid:D17D38352DF7DF11A86EE099FD0A2EDA, xmp.iid:A9348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:AA348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:AB348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:AC348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:AD348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:AE348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:AF348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:B0348FF5C5F7DF1188AAFEC19A31505B, xmp.iid:128EFE0FC9F7DF1188AAFEC19A31505B History When : 2010:11:23 11:30:05-05:00, 2010:11:23 11:33:13-05:00, 2010:11:23 11:33:13-05:00, 2010:11:23 11:38:33-05:00, 2010:11:23 11:41:58-05:00, 2010:11:23 11:43:49-05:00, 2010:11:23 11:44:13-05:00, 2010:11:23 11:45:01-05:00, 2010:11:23 11:45:26-05:00, 2010:11:23 11:45:43-05:00, 2010:11:23 11:46:03-05:00, 2010:11:23 11:46:23-05:00, 2010:11:23 11:47:12-05:00, 2010:11:23 11:48:36-05:00, 2010:11:23 11:49:58-05:00, 2010:11:23 13:10:59-05:00, 2010:11:23 13:14:58-05:00, 2010:11:24 07:35:37-05:00, 2010:11:24 07:38:44-05:00, 2010:11:24 07:41:20-05:00, 2010:11:24 07:43:11-05:00, 2010:11:24 07:45:04-05:00, 2010:11:24 07:45:44-05:00, 2010:11:24 07:46:34-05:00, 2010:11:24 07:47:14-05:00, 2010:11:24 07:47:57-05:00 History Software Agent : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0 History Changed : /, /metadata, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, / Doc Change Count : 33 Format : application/pdf Title : GE Outdoor Floodlighting PF400 Powerflood Spec Sheet | GE Lighting Description : Explore the GE Outdoor Floodlighting PF400 Powerflood. This specification sheet provides information such as mechanical construction, ballast operation, and optical assembly information for the GE Outdoor Floodlighting PF400 Powerflood. Creator : GE Outdoor Floodlighting Subject : Outdoor lighting, ge lighting, Floodlighting, PF400 Powerflood, Spec Sheet Producer : Adobe PDF Library 9.0 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools