FLOOD LIGHTING
Guide Form Specifications – 2011
gGE
Lighting Solutions
GUIDE FORM SPECIFICATIONS
GENERAL DESCRIPTION
The NEMA heavy-duty weather-resistant floodlight designated
_______ (identify) shall be a GE PF-400® POWERFLOOD® flood-
light, ordering number _______ (specify PF4S, PF4T, plus order-
ing number logic from catalog) or approved equal, for opera-
tion of one _______ (specify [150(55V), 200, 250, or 400] watt
high pressure sodium [HPS], [175, 250 or 400] watt metal halide
or 400 watt mercury) lamp from a nominal _______ (specify
120, 208, 220, 240, 277, 347 or 480 volt, 60 Hz or 220, 230 or
240 volt, 50 Hz) power source and shall be capable of start-
ing and operating the specified lamp within the limits speci-
fied by the lamp manufacturer. The floodlight shall contain a
completely prewired integral ballast and optical assembly with
_______ (specify 3X2, 4X2, 4X4, 5X4, 6X4, 6X5, 6X6, 7X6 or 7X7
according to photometric selection table in the catalog) NEMA
type beam spread (horizontal X vertical). The floodlight shall
have a NEMA lamp identification decal. The floodlight shall be
UL/cUL Listed SUITABLE FOR WET LOCATIONS. Standard con-
struction is IP55. Ballast, housing, optical and luminaire assem-
bly shall all be from the same manufacturer.
OPTICAL ASSEMBLY
PF-400 ® POWERFLOOD ® FLOODLIGHT
The optical assembly shall be sealed with a gasket around
the perimeter of the front access door, contain an activated
charcoal filter and include a formed aluminum reflector and
heat/impact-resistant flat door glass. The reflector shall have
a chemically-bonded lightweight nonbreakable glass ALGLAS®
finish on both the inside and outside surfaces providing en-
hanced specular reflectance, corrosion resistance, durability
and ease of cleaning. The optical assembly shall contain an
E39 mogul base socket with superior lamp gripping. The socket
shall have added insulation, giving it the ability to handle the
higher pulse ratings of newer HID systems. Lamp shall be
mounted _______ (specify horizontally or vertically).
* REFER TO PRODUCT PAGE FOR OTHER BALLAST
SELECTIONS. FOR MORE DEFINITIVE INFORMATION, REFER TO
BALLAST SPECIFICATIONS IN TECHNICAL DATA SECTION.
MECHANICAL CONSTRUCTION
The floodlight shall include die-cast aluminum housing with
hinged and removable front-access door having captive screw
(or optional wire bail latches), ballast, filtered optical assembly,
_______ (specify steel trunnion [standard], die-cast aluminum
knuckle slipfitter or knuckle wall mount with integral wiring
box and vertical aiming degree markings) (and optional pho-
toelectric control receptacle). All hardware shall be corrosion-
resistant. All die-cast aluminum surfaces shall have a _______
(specify dark bronze [standard] or gray) electrocoat paint finish.
The floodlight shall have a built-in aiming sight.
BALLAST OPERATION
The ballast shall be prewired to the lamp socket and terminal
board and there shall be a plug-in type starter aid for high
pressure sodium fixtures. (For convenience of installation and
maintenance, an optional tray mount for ballast and other
electrical components is available [for use with HPS lamps
only].)
The floodlight shall contain a _______ (specify standard Au-
toreg or Mag-Reg.) type ballast* in full compliance with lamp-
ballast specifications available to the fixture manufacturer from
the lamp manufacturers at the time of fixture manufacture.
As an option the ballast may have the capability of operating
high pressure sodium or metal halide lamp at any of four volt-
ages — 120, 208, 240 or 277 volts. When specified, the multi-
watt ballast (250/400) shall be connected for 250 watts unless
otherwise specified. Check the Ballast and Photometric Selec-
tion Table before selecting a special rating.
The ballast shall reliably start and operate the lamp in ambi-
ent temperatures down to -20°F for mercury or metal halide or
-40°F for HPS.
gGE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 6 9 4 3 5 3 3- - -- 8 8 8