GE
Inspection Technologies

Solder joint inspection and analysis

with GE’s phoenix|x-ray microfocus and nanofocus X-ray systems

FAQs about X-ray
How X-ray inspection

source
small FOD

large FOD

works

object

FDD

detector

high magnification

low magnification

insulator

UH
UG

cathode
(filament)

UACC

grid
anode
deflection
unit

How X-ray tubes

What makes an excellent

work

X-ray?

The heart of the X-ray machine is an elec-

One of phoenix|x-ray’s key technology com-

trode pair consisting of a cathode, the fila-

petencies are tube and generator design and

ment, and an anode, that is located inside a

manufacturing ensuring reliable results and

vacuum tube. Current is passed through the

highest up-time.

filament heating it up, causing the filament

electron beam

magnetic
lens

X-ray starts with a sample being irradiated by an X-ray source and projected onto a
detector. The geometric magnification M of the image is the ratio of focus-detector
distance (FDD), Focus-object distance (FOD): M=FDD/FOD. The smaller the focal spot,
the greater the resolution. With the nanofocus technology an unique detail detectability down to 0.2 microns can be achieved. phoenix|x-ray systems reach geometric
magnifications over 2,000x resulting in total magnifications beyond 24,000x.

to emit electrons. The positively charged

target

anode draws the electrons across the tube.

X-ray beam

Unlike with conventional X-ray tubes, the
electrons pass through the anode into a specifically designed set-up of electromagnetic
lenses, where they are bundled and directed

Why can the collision

onto a small spot on the target, a flat metal

protection be deactivated?

the electrons collide with the target, they in-

For ultimate protection of your sample, all
phoenix|x-ray systems come standard with
a password-protected anti-collision feature. But when inspecting certain samples,
it might become necessary to deactivate
the collision protection, as for example with
25 µm bond wires, which, even for magnifications of just 500x, need to be as close as
4 mm to the tube head. phoenix|x-ray has
come up with a solution to give the user
maximum flexibility when dealing with very
small samples: Unlike with conventional
systems, the X-ray tube is located

disc covered by a layer of tungsten. When
teract with the ions in the tungsten, causing
X-rays to be emitted. Key to sharp, crisp
X-ray images at micron or even submicron
resolutions is the size of the focal spot,
meaning the ability to focus the electron
beam in such way that the area on the target
where the electrons hit be as small as possible – an obstacle yet to be overcome by
conventional X-ray machines.
However, phoenix|x-ray has mastered this
challenge with its unique nanofocus tube
providing detail detectabilities as low as 200
nanometers (0.2 microns).

GE’s unique 180 kV high power nanofocus X-ray tube

•	 High power nanofocus X-ray tubes up
to 180 kV and unipolar microfocus X-ray
tubes up to 300 kV maximum voltage.
•	 Down to 200 nm (0.2 microns) detail
detectability.
•	 Anti-arcing: dedicated surface treatment
during fabrication and automated warmup procedures prevent discharges.
•	 Self adjustment: all tube adjustments are
performed automatically during warm-up
to achieve optimum results.
•	 Plug-in cathodes: pre-adjusted spare cathodes prevent malfunction due to wrong
filament adjustment and minimize downtime to less than 20 min.
•	 long-life|filament: ensuring high emission
current CT with up to 10 times increased

above the sample tray

filament lifetime of directional target

allowing the user to

tubes.

move the sample as

•	 diamond|window: high output of up to

close to the tube head

max. 20 W power with high-resolution.

as needed.

•	 Target check: target condition is checked
automatically; automatic target wear is
FOD‑=‑4 mm: 500 x Sample touching the tube:
Maximum magnification

indicated.

The View Inside
Why to inspect solder joints with X-ray?
The reliability of electronic assemblies strongly depends on solder joint quality. Acceptability criteria are mainly based on shape
and dimension of the solder joints. As quality demands and technology for assembly process for new package types increase,
many solder joints are no longer directly visible. Fortunately, they can easily be inspected by advanced microfocus and nanofocus X-ray systems. phoenix|x-ray offers dedicated analysis and automatic inspection solutions for any type of solder joint:

BGA type solder joints such as PBGA, CBGA, CGA, etc.
BGA

PCB

BGA: warpage BGA: solder bridge
Scheme of a BGA solder joint , X-ray image of a BGA solder joint
(top-down view)

All dimensions and features of the solder joint are imaged: diameter,
thickness (grey value), lands and contact areas (darker and brighter
>

circles), voids (bright spots). All defects that have any influence on the
solder joint's shape are detectable:
Bridges, opens, missing joints, warpage, popcorning, component tilt,
voids, diameter deviations, roundness, shape deviations (roundness),
fuzzy edges (insufficient reflow), misregistration.

BGA: voiding BGA: insufficient reflow

Gull Wing and flat ribbon solder joints such as
QFP, SOT, PLCC, Chip devices etc.

Lead

PCB

QFP: weak heel fillet SOT: defective paste print

>

Scheme of a Gull Wing (QFP) solder joint, X-ray image of a QFP
solder joint (top-down view)

>

In addition to toe and side fillets the X-ray image reveals hidden features of the interconnection: the heel fillet which is most important for
the reliability of the solder joint and voids.
Detectable defects: Bridges (in particular under the component),

>
>

>

lets, de-wetting, insufficient reflow, mis-registration, cracks.

>

opens, defective paste print, insufficient co-planarity, incomplete fil-

SMD: crack MLF: two open joints

The Third Dimension
Just look from the side
ovhm - oblique views at highest magnification
Some acceptability criteria refer to a side view and many
defects can be seen best from the side, in other words, some
information about the vertical dimension is required.
phoenix|x-ray systems provide this information by oblique view
– up to 70 degrees – at highest magnification. As an
example, this enables the user to see open BGA solder joints
directly instead of interpreting signatures.

70°

45°
0°
BGA

>

PCB

ovhm: oblique views give excellent information in the vertical direction. At 70 degrees
the profile of these CSP solder joints is fully displayed and even the void position can
be clearly determined. In contrast to 45 degrees, at 70 degrees the component and
board pads are completely separated and can be inspected without any interference.

Scheme of non-wetted BGA land and its detection by
ovhm: the land is empty

BGA

Technology

>

PCB

>

X-ray tube

Scheme of non-wetted BGA ball and its detection by ovhm:
paste solder and ball are separated

detector
0 - 70°

Conventional tilting vs. ovhm

ovhm: Oblique views at highest
magnifications

Leads

>

PCB

Conventional tilt techniques generate
oblique views by simply tilting the sample
to the side, which involves moving one part
of the sample further away from the X-ray

Scheme of THT solder joints and their inspection by ovhm: one
through-hole is not filled and the hole plating is not wetted by
the solder

tube resulting in a decrease in magnification. The ovhm|module was specifically
designed to enable oblique views of up to
70 degrees and 0 to 360 degree rotations without a decrease in magnification.
Magnification remains the same because
the distance between focus and sample
does not change while the detector is being tilted.

Automated Inspection
The efficient way of process control and rework
Efficient soldering process control requires the acquisition of statistical data on the solder joints of a larger number of samples.
phoenix|x-ray offers a range of plug-in software modules for the automated evaluation of standard solder joints like BGA, QFP,
QFN, or PTH. For non-typical interconnections, appropriate modules can quickly be customised with the XE² (X-ray image Evaluation Environment) software. Together with the high precision CNC manipulation which comes standard with phoenix|x-ray
systems these modules enable the automated X-ray inspection (AXI) of solder joints at minimum set-up time, due to teach-in
programming and auto-setup routines. An additional software package – quality|review – is the perfect connection to rework.
phoenix|x-ray's inspection modules can also easily be activated during manual inspection as a quick inspection aid.

phoenix x|act µAXI
Fully automated CAD based high-resolution X-ray inspection for extremely high defect coverage
As a solution for µAXI with high magnification and repeatability, GE provides calibrated high precision offline µAXI systems including the unique
phoenix x|act software package for fast and easy offline CAD programming. Small views with a resolution of up to a few micrometers, 360° rotation and oblique viewing up to 70° ensure to meet highest quality standards. Besides the automated X-ray inspection, the μAXI system can be
used for manual failure analysis or 3D computed tomography as well.

Fast and easy programming: just assign the inspec‑
tion strategies and let x|act generate the automated
inspection program

Live CAD overlay in ovhm with inspection results
Visualization of board distortion

Efficient CAD programming

3D auto-referencing

Live 3D CAD overlay

minimized setup time

optimized positioning accuracy

highest magnification in oblique view

•	 Import of CAD-data
•	 Easy pad-based offline programming
•	 Optimized inspection strategies for
different pad types

•	 Fully automated generation of inspection
program even in oblique view and multiple
angular positions per component

•	 Full program portability for all compatible
phoenix|x-ray inspection systems with
x|act

Automated measurement and compensation
of height differences and distortions:

•	 phoenix|x-ray inspection systems equipped with x|act operator or pro come standard with high precision CNC manipulation

•	 Local 3D height and distortion referencing
by X-ray

•	 Highest precision through use of multiple

•	 Perfect orientation through live overlay of
CAD-data and test results even in rotated
oblieque views

•	 Pad ID available at any time
•	 Inspection results and images include
	 correct pad numbering for easy rework

•	 Easy pad identification even in manual
inspection

fiducials

•	 Automated correction of image chain
distortion

•	 Extremely high positioning accuracy even
at oblique viewing and rotation

Inline or offline inspection?
throughput of the SMT line. Principally, X-ray inspection takes much more time
than AOI. The higher the defect coverage, the more inspection time is required.
For zero defect production inspection with small fields of view with micrometer
resolution, 360° rotation and oblique viewing up to 70° is essential. To ensure
these higher defect coverage requirements, μAXI has to be performed beside
the production line.

Technology

With common inline AXI, the inspection depth is normally determined by the

Anticipating the Future
Inspecting the smallest and finest
nanofocus and digital imaging
Miniaturization and new assembly techniques demand resolution in the submicron range and also highest contrast
resolution. With the nanofocus tube technology together with digital image chains
or fully digital detector arrays,
40 micron solder bumps at
nanofocus resolution

phoenix|x-ray provides proven detail
detectability down to 200 nm (0.2 microns)
combined with superior contrast resolution. In this way fine details and slight

High-resolution 3D-imaging
nanoCT®
The combination of phoenix|x-ray's high-power nanofocus
X-ray tube and optimized reconstruction software enables
unprecedented nanoCT® image resolution and quality. This
technology allows the inspection and 3-dimensional visualization of the internal details of smaller specimens with submicrometer voxel resolution.

variations in thickness, such as those
caused by tiny voids in microscopic Flip
Chip solder joints are detected.

40 micron solder bumps at
microfocus resolution

High dynamic digital detectors

nanoCT® of a BGA ball with cracks of 1-8 µm

Active temperature stabilization
The image quality is essential for an optimal defect coverage of all
2D and 3D inspection tasks. Due to its high dynamic, the new active
temperature stabilized GE DXR digital detector arrays ensure a very
low noise fast and detailed live inspection with up to 30 frames per
second at full resolution. This makes it possible to run a 3D CT scan
within only 10 seconds.

Open BGA with head-in-pillow-effect;
metallic dendrites visible in the eutectic matrix

Technology

Technology

phoenix|x-ray systems help you
meet the standards

What is the difference between
nanofocus and microfocus tubes?

The phoenix|x-ray solder joint inspection

Although the
focal spot of
microfocus tubes
object
is as small as 3
microns, it is still
large enough
detector
to cause a half
shadow, known
microfocus system nanofocus system
as the penumbra
effect. This results in a residual unsharpness and can be avoided by using nanofocus technology. Nanofocus provides focal
spots well below one micron while maintaining the highest intensity needed.

software modules include all X-ray accessible criteria mentioned in the commonly
applied standards for acceptability of PCB
assemblies, namely:

•	 IPC-A-610 Revision E
•	 IPC 7095
The modules are continuously updated to
adapt them to revisions of the standards.

source

Systems
GE’s phoenix|x-ray business offers a wide range of systems and system configurations dedicated to various 2D and 3D inspection
tasks in printed circuit board assembly:

phoenix nanome|x

phoenix nanotom s and m

the ultimate nanofocus X-ray solution

outstanding spatial and contrast
resolution on a wide sample range

This automated X-ray system with superior
specifications satisfies even the highest

Both versions of the nanotom come stan-

demands: The 180 kV / 15 W high-power

dard with a 180 kV / 15 W ultra high-perfor-

nanofocus tube (4-in-1) covers the full range

mance nanofocus X-ray tube and precision

from submicron resolution to high intensity

mechanics for extremely high stability.

applications. Due to the easy view configu-

With voxel resolution as low as < 500 (s) or

ration the X-ray image displays the sample

even <300 (m) nanometer and below, the nanotom is the inspection solution of choice for 3D

exactly as the operator sees it through the

nanoCT® applications in a wide range of fields. Equipped with its unique high dynamic tem-

radiation protection window. The digital

perature stabilized 3,072 x 2,400 pixels GE DXR detector, the nanotom m scans samples up

realtime image chain with 4 MPixel camera

to 240 mm in diameter. With its small footprint, the nanotom is suitable for even the smallest

provides an excellent contrast resolution

labs. For many research applications, the nanotom offers even a viable alternative to syn-

and enables oblique views up to 70 degrees

chrotron-based computed tomography.

and magnifications well above 24,000 x. For
samples of poor contrast the system may be
equipped with a high dynamic fully digital
DXR detector array – as supplement to the
image chain, offering unique performance
and versatility as well as live imaging with up
to 30 fps. Optionally, the nanome|x may be
equipped with nanoCT® capability.

phoenix microme|x

phoenix x|aminer

automated solder joint inspection

strong entry-level inspection system

The phoenix microme|x is a high-resolution
automated X-ray inspection (AXI) system
that is suitable for failure analysis in the
semiconductor and electronics industry.
The microme|x combines proven highresolution 2D and 3D X-ray technology in
one system. This system comes standard
with an ultra high-performance 180 kV / 20 W
X-ray tube for sub-micron feature recognition

The tube makes the difference:
phoenix nanome|x / microme|x

> 0.5 µm and a high-resolution 2 MPixel digital

With it’s 160 kV / 20 W microfocus X-ray tube,

image chain. The microme|x provides a total

GE’s phoenix x|aminer meets the require-

optical magnification of up to 23,320 x and

ments for high-resolution X-ray inspection

oblique angle views of up to 70 degrees.

of electronic assemblies, components and

Optionally, it may be equipped with GE’s

PCBA. The phoenix x|act base software pack-

DXR digital detector array for brilliant live

age offers ease of use allowing manual as

imaging and the capability for high-resolu-

well as automated solder joint inspection.

tion CT for advanced 3D failure analysis.

What does “easy and intuitive use“ mean?
•	 Due to the “Easy View Configuration“ the X-ray image shows the 		
	
	

object exactly as the operator sees it through the radiation
protection window
•	 Precise and easy operation by using the mouse, joystick or key		
	board
•	 phoenix|x-ray systems can be operated in either sitting or standing 		
	position
•	 Programming is possible in different layers of complexity, each of 		
	 them supported by an intuitive graphically oriented or CAD based 		
	 user interface

Technology
Closed tube or open tube?
Closed tubes: All tube components are contained in a sealed vacuum vessel container.
Closed tubes are maintenance-free and are
completely replaced at the end of their lifetime.
Open tubes: All components and wear-out parts
are accessible and replaceable, the tube is continuously evacuated by a turbomolecular pump.
Open tubes yield higher resolution and magnification and are not limited in lifetime.

Regional Contact Information
Europe, Asia, Africa, South America
GE Sensing & Inspection Technologies
Niels-Bohr-Str. 7
31515 Wunstorf
P.O. Box 6241
31510 Wunstorf
Germany

Tel.: 	
+49 5031 172 0
Fax: 	 +49 5031 172 299
E-mail: 	 phoenix-info@ge.com
	phoenix-asia@ge.com

Americas
GE Inspection Technologies, LP
50 Industrial Park Rd
Lewistown, PA 17044
USA

Tel.: 	 +1 (717) 242 0327
Fax: 	 +1 (717) 717 242 2606
E-mail: 	 phoenix-usa@ge.com

www.ge-mcs.com/phoenix

GEIT-31101EN (11/11)
© 2011 General Electric Company. All Rights Reserved. Specifications subject to change without prior notice. nanotom and nanoCT are registered trademarks of General Electric Company. Other company or product
names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51
Instance ID                     : uuid:61200726-4745-44e8-b7bd-00311b7bc6a8
Document ID                     : adobe:docid:indd:0ba63f15-df32-11de-bc32-918012be8041
Original Document ID            : adobe:docid:indd:0ba63f15-df32-11de-bc32-918012be8041
Rendition Class                 : proof:pdf
History Action                  : saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:DC1AAA4CC0F8E0118DBFE48276ADB394, xmp.iid:DD1AAA4CC0F8E0118DBFE48276ADB394, xmp.iid:995697F98DF9E011965A967FB7319EF4, xmp.iid:43B6E13D42FEE011B4A7910908D4BFF1, xmp.iid:68426F0FCEFFE01196EFD5B9B7ED52BB
History When                    : 2011:10:17 15:02:42+02:00, 2011:10:17 15:02:42+02:00, 2011:10:18 15:34:59+02:00, 2011:10:24 15:15:28+02:00, 2011:10:26 14:28:50+02:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata
Create Date                     : 2011:10:26 16:47:33+02:00
Modify Date                     : 2011:10:26 16:47:50+02:00
Metadata Date                   : 2011:10:26 16:47:50+02:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 9514 bytes, use -b option to extract), (Binary data 11227 bytes, use -b option to extract)
Doc Change Count                : 2818
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS5.5 (7.5)
EXIF Metadata provided by EXIF.tools

Navigation menu