Ge Small Dc Motors Fact Sheet
Ge-Small-Dc-Motors-Fact-Sheet-656393 ge-small-dc-motors-fact-sheet-656393
2015-03-11
: Ge Ge-Small-Dc-Motors-Fact-Sheet-656393 ge-small-dc-motors-fact-sheet-656393 ge pdf
Open the PDF directly: View PDF .
Page Count: 180
Download | |
Open PDF In Browser | View PDF |
Buyers’ Guide Direct Current Motors 1-3000 HP General Information Page General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 General Information Index Air Flow Schematics: CD180AT through CD6900 Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Replacement Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7 Motor Pricing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 SAM-QC Form: Basic Requirement Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 SAM-QC Form: Minimum Data Check Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.11 Modifications Pricing Motor Cutaway: Kinamatic™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8 Terms Other Application Information Outline Dimensions Accessories & Modifications Pump Motors: CD180AT through CD6900 Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.12 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 1.1 Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information General Description Introduction Motor Finish Designed to meet NEMA specifications, GE’s complete line of DC motor offerings are available to meet all of your DC motor needs. The Kinamatic™ and CD6000 series of motors featured in this publication are a result of many years of research and development. Quality components and craftsmanship are designed to provide years of dependable motor performance. Our standard motor or generator paint is a machine tool ANSI #49 grey, heavy duty acrylic enamel over a water based primer. Polyurethane paint is available for waterproof motors. Frames Rugged magnetic ring frame construction of Kinamatic motors and heavy duty fabricated CD6000 frames designed for optimum motor performance. Bearings Antifriction bearings permit mounting of standard CD320AT and below frame sizes at any angle and CD365AT-CD5010AY frames mounted vertical shaft down. For easy maintenance, CD6000 have antifriction bearings and removable bearing cartridges and caps. TREC® Field Coils Tape Reinforced Encapsulated Construction (TREC®) of all main field coils and commutating field coils is a process which strengthens, seals, and bonds the coil to the pole to form a single unit that is highly resistant to contamination, vibration, impact, and wear. The TREC coil is engineered to be elastic enough to withstand expansion and contraction due to temperature differences. The TREC coil is standard on frames CD365ATCD5010AY and CD6000-CD6900. Insulation Kinamatic and CD6000 series DC motors have Class F insulation containing a number of components rated Class H, unless otherwise specified. The insulation system employs many proprietary materials and processes developed specifically for this line of machines. The system was chosen to provide long life at rated loads and also to withstand the effects of mechanical shock, vibration, and the contamination of many severe environments. The Class F insulation system has been proven by laboratory tests and by many years of successful operation. TIG Welding Low maintenance, trouble free commutator riser joints are provided by TIG (Tungsten Inert Gas) welding commutator risers to the armature coil. This strong copper-to-copper connection eliminates the use of material with low melting temperatures and greatly increases the motor’s ability to withstand overloads. Terms Other benefits of TIG welding include excellent mechanical strength and overload capacity, no tin or lead contaminants, and no throwing of solder. (TREC® coils shown above) Armature Treatment Radiant Heat Process (RHP) All armatures in frames CD180AT-CD500AT are treated with a solventless polyester varnish, Radiant Heat Process. Armatures, in horizontal position, are rotated under radiant electric heaters. After preheating, the armatures are dipped and rotated under heaters to cure the varnish. This process locks the resin in place, filling the voids. Vacuum Pressure Impregnation (VPI) All armatures in frames CD6000-CD6999 are given a vacuum pressure impregnation (VPI) treatment with high temperature varnish. Armatures are placed into a vacuum vessel that pulls air from the armature. Resin is then allowed into the vessel, and pressure is applied. The pressure pushes the resin into the voids. The armature is then drained and baked. Two VPI cycles ensure an even varnish coating and an excellent heat transfer path while eliminating all air pockets. ® Registered Trademark of General Electric Company 1.2 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Below is a listing of the enclosures offered by GE as defined by the National Electrical Manufacturer’s Association (NEMA). In addition, the International Electrotechnical Commission (IEC). Enclosure codes are shown for reference. This is a guide only. Refer to GE for special applications or labeling requirements. IP-22 IC-01 DPFG-SV Dripproof fully guarded, separately ventilated IP-22 IC-17 DPFG-BV Dripproof fully guarded, blower ventilated IP-22 IC-06 ESV Enclosed separately ventilated, air ducted in and out IP-44 IC-37 SPFG Splashproof fully guarded, self-ventilated IP-23 IC-01 SPFG-SV Splashproof fully guarded, separately ventilated IP-23 IC-17 SPFG-BV Splashproof fully guarded, blower ventilated IP-23 IC-06 Protection Cooling TENV Totally enclosed nonventilated IP-44 IC-410 TEFC Totally enclosed fan cooled IP-44 IC-411 TEAO Totally enclosed air-over-frame IP-44 IC-416 TEAAC Totally enclosed air-to-air cooled IP-44 IC-666 TEWAC Totally enclosed water-to-air cooled IP-44 IC-86W TENV-WP Totally enclosed nonventilated, waterproof IP-45/55** IC-410 TEFC-WP Totally enclosed fan cooled, waterproof IP-45/55** IC-411 TEAO-WP Totally enclosed air-over-frame, waterproof IP-45/55** IC-416 Protection Cooling Totally Enclosed (TE) Explosionproof (XP) TENV-XP Totally enclosed nonventilated, explosionproof * * TEFC-XP Totally enclosed fan cooled, explosionproof * * TEAO-XP Totally enclosed air-over-frame, explosionproof * * Modifications Pricing Cooling Dripproof fully guarded, self-ventilated Accessories & Modifications Protection DPFG Motor Pricing IEC Enclosures Dripproof (DP) Outline Dimensions NEMA Enclosures General Information Enclosures Terms Other Application Information * not defined ** IP-45: Drain Holes Open IP-55: Drain Plugs Installed (special maintenance required) www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 1.3 Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Enclosures Dripproof, Fully Guarded The standard Dripproof, Fully Guarded (DPFG) machine allows successful motor operation when drops of liquids or solid particles strike or enter the enclosure at any angle from 0º to 15º downward from the vertical. Openings are protected to prevent entrance of objects larger than 3/4” in diameter. Air openings are provided for easy conversion to splashproof enclosure or for convenient connection of ducting for separate ventilation. CD180AT frame DPFG motors mounted sidewall and vertical shaft end up will not be DPFG in that position, but will be open fully guarded (OFG). Dripproof Fully Guarded Self-Ventilated (DPFG) Totally Enclosed The standard Totally Enclosed Nonventilated (TENV) or Totally Enclosed Fan Cooled (TEFC) motor provides effective protection against adverse environmental conditions. Among these conditions are dust, shavings, or other foreign materials which are not classified as hazardous gas or dust conditions. These machines are enclosed to prevent the free exchange of air between the inside and outside of the motor frame, but are not air-tight. Explosionproof The standard Explosionproof (XP) motor is a totally enclosed machine with a housing constructed to contain any explosion within the motor caused by the hazardous atmosphere entering the enclosure and being ignited. An explosionproof motor prevents the equipment from triggering a general fire or explosion. Other Application Information Totally Enclosed Fan Cooled (TEFC) Terms Totally Enclosed Fan Cooled Explosionproof (TEFC-XP) 1.4 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Air Flow Schematics Dripproof Fully Guarded*, Blower Ventilated (DPFG-BV) (CD218AT-CD5010AY frames have blower mounted on commutator end.) *Could also be Splashproof Fully Guarded. Blower positions and optional blower locations based on the position of the conduit box. Frame Size 180AT 210AT to 5010AY CB Location CD6000 to CD6900 Blower Locations Available Top F1 CE-F1, F2 DE-F1, F2 F1 N/A CE-F2, top DE-F2, top F2 N/A CE-F1, top DE-F1, top NOTE: CE = comm end, DE = drive end F1 = right side when viewed from the motor comm end, feet down F2 = left side when viewed from the motor comm end, feet down Terms Terms Other Other Dripproof Fully Guarded, Separately Ventilated (DPFG-SV) Application Application OutlineOutline Accessories Accessories & Modifications & Modifications Motor PricingMotor Stock Pricing Motor Information InformationDimensions Dimensions Modifications Modifications Pricing Pricing Pricing Dripproof Fully Guarded, Self-Ventilated (DPFG) General General Information Information CD180AT-CD6900 Frames www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 1.5 Air Flow Schematics Totally Enclosed Nonventilated (TENV) Totally Enclosed Air-Over-Frame (TEAO) Modifications Pricing Motor Pricing General Information CD180AT-CD6900 Frames Accessories & Modifications Totally Enclosed Fan Cooled (TEFC) Totally Enclosed Air-to-Air Cooled (TEAAC) Terms Other Application Information Outline Dimensions Totally Enclosed Water-to-Air Cooled (TEWAC) Dwg. No. LO.MISC. 118R00 1.6 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Pricing: Use standard pricing given in this publication, plus add for special shaft dimensions (page XX, item XX) and a transition base (page XX, item XX). 3. Dimensional Duplicate (Obsolete duplicate) This option applies only to older GE motors and is only required when a mechanically interchangeable replacement motor is not applicable (e.g., shaft height difference does not 1. Standard Replacement allow for a transition base, or motor is coupled at both ends The new motor will be our standard offering (Kinamatic and a dimensional duplicate of the frame is required). the motor shown in this publication) which duplicated the older new motor will duplicate the older motor’s basic rating motor’s basic rating (horsepower, armature volts, field volts, (horsepower, armature volts, field volts, and field winding and field winding type). The new motor will not duplicate the type). The new motor will duplicate critical dimensions of the older motor’s winding characteristics (e.g., resistance, older motor’s frame and shaft(s). the new motor will be inductance, amperage, or regulation). The new motor will not updated with current electrical features, will not necessarily duplicate the older motor’s drive end shaft dimensions or duplicate the older motor’s winding characteristics (e.g., frame dimensions. The new motor will not duplicate the older resistance, inductance, amperage, or regulation). Standard motor’s armature inertia, overall frame height, or overall Class F rise, 1.0 service factor, and NEMA standard overloads frame length. Standard Class F rise, 1.0 service factor, and (as defined on page XX, item XX) will not apply unless NEMA standard overloads (as defined in the Accessories and otherwise specified. The new motor will be supplied with the Modifications section, page XX item XX) will apply unless up-to-date versions of the accessories of the older motor. otherwise specified. The new motor will be supplied with Pricing: Refer to GE for producibility and pricing. up-to-date versions of the accessories of the older motor. This option is available if, and only if, the shaft height of the older motor is reasonably higher (varies with motor size, but typically greater than 1 inch is sufficient) than the shaft height of the Kinamatic motor at the same rating. The new motor will be our standard offering (Kinamatic motor shown in this publication) which duplicates the older motor’s basic rating (horsepower, armature volts, field volts, and field winding type). By special machining the drive end shaft, www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Motor Pricing Other 2. Mechanically Interchangeable Replacement (Up-to-date replacement) GE suggests that all non-direct motor replacement orders be Print and Motor Data Approval Required. GE is not responsible for mechanical or electrical replacement problems encountered in the field. Terms Pricing: Use standard pricing given in this publication. Modifications Pricing To replace a motor which has different mounting dimensions than the Kinamatic motors shown in this publication (e.g., a motor made by a different manufacturer or an older GE motor), three options exist. When replacing a motor made by a different manufacturer, all of the information listed on the SAM-QC form (pages XX and XX) is required for quoting and manufacturing. When replacing an older GE motor, the model and serial number of the original motor are required for quoting and manufacturing a replacement. Accessories & Modifications Non-Direct Replacement Outline Dimensions A GE DC motor with a model number which has the format, 5CDNNNLLNNNLNNN, 5CDNNNLLLNNLNNN or 5BYNNNLLNNNLNNN (where N=number and L=letter) will be replaced with an exact electrical/mechanical replacement of the original motor. The new motor will be supplied with the up-to-date versions of the accessories. the new motor will duplicate the older motor’s mounting dimensions. (C & FC dimensions may vary from original). The new motor will not duplicate the older motor’s winding characteristics (e.g., resistance, inductance, amperage, or regulation). The new motor will not duplicate the older motor’s armature inertia, overall frame height, or overall frame length. Standard Class F rise, 1.0 service factor, and NEMA standard overloads (as defined in the Accessories and Modifications section, page XX, item XX) will apply unless otherwise specified. The new motor will be supplied with the up-to-date versions of the accessories of the older motor. Application Information Direct Replacement General Information Replacement Motors 1.7 Motor Cutaway Quality, Reliability and Serviceability A NEMA Enclosures C B Frames D • Round steel frames • Bored to provide precise seating of main and commutating poles • Precision rabbets for mounting of bearing brackets Outline Dimensions Bearings • D ouble shielded bearings on frames CD180AT - CD2110AT • Open ball bearings on frames CD258AT - CD5010AY • Regreasable features with easy access alemite fittings to extend bearing life • Dripproof, Totally Enclosed, Explosionproof • All enclosures are customizable to fit specific application requirements Armature • R adiant Heat Process (RHP) on CD180AT - CD5010AY frames • Dip and bake process cures the varnish, preventing voids and protecting against moisture and contaminates • Controlled glass banding stabilizes armature to withstand frequent starts, stops, and reversals • Commutator risers TIG welded to armature coils - Eliminates hazards of tin or lead contaminates Accessories & Modifications Modifications Pricing Motor Pricing General Information Kinamatic B J G Application Information H I D E C Other A Terms F 1.8 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Motor Cutaway Brush Rigging G Easily accessible Oversized fabricated steel box Rubber gasketed mounting and clam shell Bronze grounding lug Rotatable 360° and F2 mounting capabilities make field adaptation easy in any application Insulation • Class F system with Class H components • Withstands effects of mechanical shock, vibration and contamination • Long life at rated loads H Accessory Mounting Face • Commutator end C-face • Shaft suitable for tachometer and speed limit switch • Drilled and tapped mounting holes I J Coils • Random Wound Coils - Frames CD180AT - CD329AT - Wrapped with Mylar* composite and fiberglass tapes - Dip and bake process allows varnish to penetrate the windings • TREC* (Tape Reinforced Encapsulated Construction) Coils - Frames CD360AT - CD5010AY - Tightly seals coil to the pole, resisting outside contamination, vibration, impact and wear - Excellent heat transfer extends motor life - Engineered to withstand thermal expansion and contraction Accessories & Modifications • • • • • Conduit Box Outline Dimensions F Modifications Pricing • Field proven design that requires no adjustment • Heavy cast brush holders with quick release brush springs provide for easy maintenance • Constant pressure springs stabilize brush contact to ensure proper commutation and improve brush wear Application Information E Motor Pricing General Information Kinamatic Lifting Lugs Terms Other • Welded into frame on CD210AT - CD5010AY frames • Cast in endbell on CD180AT frame • Lifting system is safer than a single eyebolt lifting system * Trademark of General Electric Company. Mylar® is a registered trademark of DuPont Tejin Films. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 1.9 SAM-QC Form Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Specify a Motor Quickly and Correctly Basic Requirement Instructions The following form is designed to provide guidance through the minimum requirements needed to quote a DC Kinamatic or CD6000 frame motor. To ensure GE meets your specific needs, each quote must include the following information: A. Customer Identification Information B. Basic Motor Description C. Additional Modifications Customer Identification Information Section A – Identification information includes key customer details that will help establish a customer profile. This section also includes the following information that, although not necessary, may be extremely helpful in distinguishing special motor needs. a. Model Number b. Serial Number Basic Motor Description Section B – Basic Motor Description includes each of the following items and are essential in providing the correct motor specifications to meet the needs of customer applications. These DC motor offerings can be reviewed for both the Kinamatic and CD6000 frame motors in the “Standard Features” section on page ___ at the beginning of the motor pricing tab. 1. Horsepower* 2. Base Speed* 3. Top Speed 4. Armature Voltage* 5. Field Voltage * 6. Type of Field* 7. Enclosure* 8. Orientation* 9. Mounting 10. Duty Cycle 11. Direction of Rotation 12. Temperature Rise 13. Ambient 14. Altitude 15. Service Factor 16. Conduit Box Location Other * Information REQUIRED to provide a quote Additional Modifications Terms Section C – Additional Selections include all accessories featured in the “Accessories and Modification” section beginning on page 3.1. 1.10 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. SAM-QC Form General Information Minimum Data Check Sheet Check features that apply, and specify descriptions as needed SECTION A – Customer Identification Information Mounting: p C-Face Footed p D-Flange Project Name: p C-Face Footless p P-Base Motor Pricing 9. Customer: 10. Duty Cycle: p Continuous (Standard) p Other (Please specify: e.g 30 min, 60 min) Tracking Number: Date: Due Date: Quote Number: p Reversing (Standard) a. Model Number: p Clockwise Modifications Pricing 11. Direction of Rotation: p Counter Clockwise 12. Temperature Rise: p Class F b. Serial Number: p Class B 13. Ambient: Horsepower*: 2. Base Speed*: 3. Top Speed*: 4. Armature Voltage*: p 3300 Ft (Standard) 15. Service Factor: p 1.0 (Standard) p 600 p Other F1-RHS from CE (Standard) p 150/300 Type of Field*: SECTION C – Additional Modifications p Stabilized Shunt p Compound Enclosure*: p DPFG – Dripproof Fully Guarded p DPFG-BV – Dripproof Fully Guarded Blower Ventilated p DPFG-SV – Dripproof Fully Guarded Self-Ventilated p TENV – Totally Enclosed Nonventilated p TEFC – Totally Enclosed Fan Cooled p TEWAC – Totally Enclosed Water-to-Air Cooled p TEAAC – Totally Enclosed Air-to-Air Cooled p TEAO – Totally Enclosed Air-Over-Frame p TENV-XP – Totally Enclosed Nonventilated, Explosionproof p TEFC-XP – Totally Enclosed Fan Cooled, Explosionproof 8. 16. Conduit Box: Location: Field Voltage*: p Shunt Wound (Standard) p Series 7. p 750 p Other Outline Dimensions p 500 p 100/200 p 120/240 p Volts 6. p Other Modifications can be found on page 3.1 in section 3 of this catalog. Refer to GE with any additional specializations. List all additional modifications/accessories below, with details regarding dimensions, size, requirements and etc.: Orientation*: p Horizontal (Standard) p Vertical p Shaft Up Terms 5. p 240 Volts 14. Altitude: Other p 180 p p Other Accessories & Modifications 1. p 40ºC (Standard) Application Information SECTION B – Basic Motor Description p Shaft Down * Information REQUIRED to provide a quote www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 1.11 Pump Motors Accessories & Modifications Modifications Pricing Motor Pricing General Information CD180AT through CD6900 Frames DESCRIPTION – Pump Motors DC Motors with armature voltages from 105-130 Volts in most cases are used in pump applications. These are special motors built to pump manufacturer specifications. Because of the low armature voltage these motors have special electrical designs and in many cases frame sizes are larger than standard. If a model number is not available, a request for motors in this voltage range must be accompanied by the following information. Typically Motor RPM will be lower than nameplate speed (approximately 10-15%) when cold and increase to nameplate RPM as main field reaches operating temperature. To reduce the cold to hot speed variations, the shunt fields should be energized at 50 to 70% of rated voltage to stabilize. However, for ‘emergency’ pump motor applications, where field pre-heating may not be feasible, the pump capacity must be sized to the cold start RPM. Pump motors operated from DC potential busses or batteries will show significant speed variations from nominal when the motor is cold and when the applied voltage varies below nominal. Also at lower than nominal voltage the motor will run slower than nameplate RPM, while conversely the motor will run higher than nameplate RPM when voltage is higher than nominal. PUMP FORM Outline Dimensions Altitude Customer: Horsepower: Enclosure: Duty: Temperature Rise: p Class F Base Speed: p DPFG p TENV p Explosionproof p Cont. Power Supply: p Battery p TEFC p Waterproof p 60 Min. °C Feet (Standard is 3300 feet) p 30 Min. p Constant Voltage p Class B Service Factor: p 1.0 p 1.15 Rotation: p CCW p CW Space Heater: Heater Voltage p 120V p 240V p Other p None Armature Voltage: Volts Thermostat: p N.C. Field Voltage: Volts Conduit Box: p Standard If Battery Supply: Anticipated Voltage Swing From Nominal +/– What %? Minimum Cold Running Speed and Voltage Field Winding: p Shunt p Compound p Reversing p N.O. p Oversize p Waterproof Conduit Box Location: (as viewed from comm end of motor) p Right Side p Left Side p Top RPM p Stab Shunt Voltage Mounting: p Vertical Shaft Up p Vertical Shaft Down p Horizontal Mounting Flange p C-Face (If required) p D-Flange p P-Base Drawings must be supplied for P-Base Terms Other Application Information Max. Ambient Temp. Where Used: 1.12 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Motor Pricing Page Kinamatic™ Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 General Information Index 180 Volt Motors, Self-Ventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 180 Volt Motors, Totally Enclosed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 Motor Pricing CD6000 Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 240 and 500 Volt Motors, Separately Ventilated, 1 HP-7.5 HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 240 and 500 Volt Motors, Self- and Separately Ventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8 Modifications Pricing 240 and 500 Volt Motors, Self-Ventilated, 1 HP-7.5 HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 600 and 700 Volt Motors, Separately Ventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13 Totally Enclosed Nonventilated Motors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14 Totally Enclosed Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15 Totally Enclosed Motors, Unit Cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16 Outline Dimensions 600 Volt Motors, Separately Ventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12 Accessories & Modifications 500 Volt Motors, Separately Ventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11 Totally Enclosed Nonventilated, 60 Minute Motors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.22 Explosionproof and Dust-Ignitionproof Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.23 Papermill Duty Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.26 Application Information Totally Enclosed Nonventilated, 30 Minute Motors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.21 Papermill Duty, Splashproof Separately Ventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.27 Other Papermill Duty, Totally Enclosed Nonventilated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.26 Terms Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.29 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.1 Standard Features HP Range 1-500 Base Speed 300-3500 RPM Armature Voltage 240V, 500V Field Voltage 300/150V, 240/120V Accessory Mounting 8.5" accessory mounting rabbet with accessory shaft extension Agency Approvals CSA Altitude 3300 ft Ambient 40°C Balance/Vibration Measured at top speed: Peak-to-Peak Amplitude 0.0015" Bearing Caps Cast iron CD258AT-CD5010AY both DE and CE Bearing Type Anti-friction ball, CDL182AT-CD2010AT: double shielded, CD258AT-CD5010AY: open Coils CD180AT-CD329AT random wound- dip and baked CD360AT-CD5010AY TREC® Coils Conduit Box Fabricated steel, 360° rotatable, gasketed, oversized Current Overload Occasionally repeated loads of 150% of base speed full load current Endbells CD182AT-CD500AT: cast iron, CD5010AY: CE - cast iron, DE - fabricated steel Frame Material Rolled Steel Frame Size CD182AT-CD5010AY Grease Lithium soap base Ground Bronze bolt in conduit box Insulation Class Class F Insulation System Armature Treatment: Radiant Heat Process (RHP) Lifting Means Two (2) welded lifting lugs Mounting F1, modifiable to F2 Nameplate Stainless Steel Paint ANSI #49 grey, heavy duty industrial enamel Relubrication CDL182AT-CD2110AT: pre-lubricated, CD258AT-CD5010AY: zerk grease fittings Service Factor 1.0 Temperature Rise Class F @ rated load and rated base speed Tests Routine Test: Report available upon request with purchase order Warranty 24 months from date of installation or 30 months from date of manufacture; whichever occurs first Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Direct Current Motors Kinamatic™ 2.2 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. General Information Direct Current Motors CD6000 300/150V Accessory Mounting 8.5" accessory mounting rabbet with accessory shaft extension Agency Approvals CSA Altitude 3300 ft Ambient 40°C Balance/Vibration Measured at top speed: Peak to Peak Amplitude .0020" Bearing Caps Cast iron - both DE and CE Bearing Type Anti-friction ball bearings, open Coils TREC® Coils Conduit Box Large fabricated sheet metal construction with fixed buss-bar termination Current Overload Occasionally repeated loads of 150% of base speed full load current Endbells Fabricated Steel Frame Material Fabricated Steel Frame Size CD6000-CD6900 Grease Lithium soap base Ground External mounting provision Insulation Class Class F Insulation System Armature treatment: VPI (vacuum pressure impregnation) Lifting Means Four (4) welded lifting lugs Mounting F1 modifiable to F2 Nameplate Stainless Steel Paint ANSI #49 Grey heavy duty industrial enamel Relubrication Zerk grease fittings Service Factor 1.0 Temperature Rise Class F @ rated load and rated base speed Tests Routine Test: Report available upon request with purchase order Warranty 12 months of operation / 18 months from date of manufacture; whichever occurs first Accessories & Modifications 500V, 600V Field Voltage Outline Dimensions 300-1750 RPM Armature Voltage Application Information Base Speed Other 500-3000 Terms HP Range Modifications Pricing Motor Pricing Standard Features www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.3 Dripproof Fully Guarded Motors Self-Ventilated General Information Class F Insulation Type K Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 180 Volts PRICES - 180 Volts Suitable for constant torque to 60% of base speed Suitable for constant torque to 5% of base speed Accessories & Modifications Modifications Pricing Motor Pricing HP 1 1.5 2 3 5 7.5 Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A Enclosure ➂ Frame ➃ 1750 2050 $4884 DP L182AT ➄ • 1150 1380 $5472 DP L182AT 2500 2750 $4798 DP L182AT 1750 2050 $5108 DP L182AT ➄ • 1150 1380 $5874 DP 186AT 2500 2750 $4890 DP L182AT 1750 2050 $5330 DP L182AT ➄ • 1150 1380 $6342 DP 186AT 2500 2750 $4540 DP L182AT 1750 2050 $5166 DP 186AT ➅ 1150 1380 $6766 DP L186AT 2500 2750 $5146 DP 186AT L182AT ➅ • 1750 2050 $5360 DP 1150 1380 $7778 DP 218AT 1750 2050 $8580 DP 219AT Dim. Pg. HP Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A Enclosure ➂ Frame ➃ 1 1750 2050 $4886 DP L182AT ➄ • 2500 2750 $4798 DP L182AT 1750 2050 $4934 DP 186AT ➄ • 2500 2750 $5134 DP 186AT 1750 2050 $4934 DP 186AT ➄ • 2500 2750 $5134 DP 186AT 1750 2050 $5374 DP L186AT ➅ • 2500 2750 $5420 DP 189AT 1750 2050 $8580 DP 219AT ➅ • 1.5 2 3 5 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➂ NV- Totally Enclosed Nonventilated FC- Totally Enclosed Fan Cooled DP- Dripproof Fully Guarded (Self-Ventilated). ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. ➄ Stocked with 4.5” rabbet. ➅ Stocked with 8.5” rabbet. C-FACE MODIFICATION NOT ➆ Stocked with 4.5” and 8.5” rabbet. INCLUDED IN BASIC LIST PRICE. 10 Refer to GE for frame. Application Information Outline Dimensions Type CD Shunt Wound Terms Other Dripproof Fully Guarded Self-Ventilated (DPFG) (Frame CDL182AT shown above.) 2.4 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Dim. Pg. Totally Enclosed Motors Totally Enclosed Class F Insulation Type K Power Supply➁ For Continuous Operation in 40°C Ambient For explosionproof motors, refer to page ??. Suitable for constant torque to 5% of base speed HP Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A Enclosure ➂ Frame ➃ 3 1150 1380 $6990 FC 189AT 2500 2750 $6110 FC 189AT 1750 2050 $7108 FC 189AT ➅ • 5 Dim. Pg. HP 1 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➂ NV- Totally Enclosed Nonventilated FC- Totally Enclosed Fan Cooled DP- Dripproof Fully Guarded (Self-Ventilated). ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. ➅ Stocked with 8.5” rabbet. C-FACE MODIFICATION NOT ➆ Stocked with 4.5” and 8.5” rabbet. INCLUDED IN BASIC LIST PRICE. 10 Refer to GE for frame. 1.5 2 3 5 Rated Top Speed RPM Basic List Price* GO-2A Enclosure ➂ Frame ➃ 1750 2050 $4816 NV L182AT ➆ • 1150 1380 $5150 NV 186AT 2500 2750 $4886 NV 186AT 1750 2050 $5086 NV 186AT ➆ • L186AT 1150 1380 $6046 NV 2500 2750 $4984 NV 186AT 1750 2050 $5232 NV L186AT ➆ • 1150 1380 $5418 NV 189AT 2500 2750 $5646 NV L186AT 1750 2050 $5506 NV 189AT ➆ • 1150 1380 $5128 NV 2110AT 2500 2750 $7812 NV 2110AT 1750 2050 $10182 NV 2110AT ➅ • 3500 3500 $11284 NV 258AT Dim. Pg. Terms Other Application Information Outline Dimensions 7.5 Base Speed RPM Modifications Pricing PRICES - 180 Volts Suitable for constant torque to 60% of base speed Accessories & Modifications PRICES - 180 Volts Motor Pricing General Information Type CD Shunt Wound www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.5 Dripproof Fully Guarded Motors Self-Ventilated General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient 240 Volt Armature - 150/300V or 120/240V Field 500 Volt Armature - 150/300V or 120/240V Field Suitable for constant torque to 60% of base speed Suitable for constant torque to 60% of base speed 1 1.5 2 3 Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing HP Other Application Information 5 Terms Type CD Shunt Wound 7.5 Base Speed RPM Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 2300 $2198 L182AT Dim. Pg. 1 Base Speed RPM Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 2300 $2972 L182AT L182AT 1150 2000 $2476 L182AT 1150 2000 $3250 850 1750 $3202 186AT 850 1750 $3656 186AT 3500 3500 $1972 L182AT 3500 3500 $1972 L182AT 2500 3000 $2222 L182AT 2500 3000 $2222 L182AT 1.5 1750 2300 $2468 L182AT 1750 2300 $3242 L182AT 1150 2000 $2882 186AT 1150 2000 $3580 186AT 850 1700 $4300 186AT 850 1700 $5022 186AT 3500 3500 $2170 L182AT 3500 3500 $2170 L182AT 2500 3000 $2414 L182AT 2500 3000 $3188 L182AT 1750 2300 $3290 L182AT • 1750 2300 $3500 L182AT 1500 2100 $3066 10 1500 2100 $3066 10 1150 2000 $3346 186AT 1150 2000 $3580 186AT 850 1700 $4848 L186AT 850 1700 $5308 L186AT 3500 3500 $2466 L182AT 3500 3500 $2466 L182AT 2 2500 3000 $2788 L182AT 2500 3000 $3538 L182AT 1750 2300 $3938 186AT • 1750 2300 $3938 186AT • 1500 2100 $4126 10 1500 2100 $4126 10 1150 2000 $4740 L186AT 1150 2000 $5200 L186AT 850 1700 $5778 218AT 850 1700 $5778 218AT 650 1600 $6820 2110AT 650 1600 $6820 2110AT 3 500 1500 $8224 259AT 500 1500 $8224 259AT 400 1200 $10632 287AT 400 1200 $10632 287AT 300 900 $12578 327AT 300 900 $12578 327AT 3500 3500 $3214 186AT 3500 3500 $3214 186AT 2500 3000 $3772 186AT 2500 3000 $3772 186AT 1750 2300 $4914 L186AT • 1750 2300 $4914 L186AT • 1500 2100 $5300 10 1500 2100 $5300 10 1150 2000 $6064 218AT 1150 2000 $6064 218AT 850 1700 $7264 2110AT 850 1700 $7264 2110AT 650 1600 $8746 259AT 650 1600 $8746 259AT 500 1500 $11444 288AT 500 1500 $11444 288AT 400 1200 $13826 327AT 400 1200 $13826 327AT 900 $20212 365AT 186AT 5 300 900 $20212 365AT 300 3500 3500 $4336 186AT 3500 3500 $4336 2500 3000 $5032 L186AT 2500 3000 $5032 L186AT 1750 2300 $5994 218AT • 1750 2300 $5994 218AT • 1500 2100 $6464 10 1500 2100 $6464 10 1150 2000 $7318 258AT 1150 2000 $7318 258AT 850 1700 $8682 259AT 850 1700 $8682 259AT 650 1600 $11550 288AT 650 1600 $11550 288AT 500 1500 $13810 327AT 500 1500 $13810 327AT 400 1200 $16926 365AT 400 1200 $16926 365AT 300 900 $20212 368AT 300 900 $20212 368AT 7.5 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. 2.6 HP www.gemotors.com • 800-541-7191 Dim. Pg. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. GEP387M 09/11 • Prices and data subject to change without notice. Dripproof Fully Guarded Motors Separately Ventilated Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient 240 Volt Armature - 150/300V or 120/240V Field 500 Volt Armature - 150/300V or 120/240V Field Suitable for constant torque to 5% of base speed Suitable for constant torque to 5% of base speed $2198 L182AT 2 3 5 7.5 Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 2300 $2972 186AT 1150 2000 $2476 L182AT 1150 2000 10 10 850 1750 $3202 186AT 850 1750 10 10 3500 3500 $1972 L182AT 3500 3500 10 10 $2222 L182AT 2500 3000 10 10 2500 1.5 1 Base Speed RPM 3000 1.5 1750 2300 $2468 L182AT 1750 2300 $3242 186AT 1150 2000 $2882 186AT 1150 2000 $3580 10 850 1700 10 10 850 1700 10 10 2500 3000 $3188 186AT 1750 2300 $3500 186AT 1500 2100 $3066 L186AT 2500 3000 $2414 L182AT 1750 2300 $2726 L182AT 1150 2000 $3346 186AT 2 850 1700 $4848 L186AT 1150 2000 $3580 L186AT 3500 3500 $2466 L182AT 850 1700 $4848 10 2500 3000 $2788 L182AT 3500 3500 $2466 10 3000 $3538 186AT 1750 2300 $3304 186AT 2500 1150 2000 $4740 L186AT 1750 2300 $3938 186AT 850 1700 $5778 218AT 1500 2100 $4126 L186AT 1150 2000 $4740 L186AT 850 1700 $5778 218AT 650 1600 $6820 2110AT 500 1500 $8224 259AT 400 1200 $9666 287AT 650 1600 $6820 10 1500 $8224 10 3 300 900 $11436 327AT 500 3500 3500 $3214 186AT 400 1200 $9666 10 2500 3000 $3772 186AT 300 900 $11436 10 1750 2300 $4914 L186AT 3500 3500 $3214 10 1500 2100 $5300 10 2500 3000 $3772 L186AT 1150 2000 $6064 218AT 1750 2300 $4914 L186AT 850 1700 $7264 2110AT 1500 2100 $5300 218AT 650 1600 $8746 259AT 1150 2000 $6064 219AT 500 1500 $10404 288AT 850 1700 $7264 2110AT 400 1200 $12570 327AT 650 1600 $8746 10 300 900 $14686 328AT 500 1500 $10404 10 3500 3500 $4336 186AT 400 1200 $12570 10 900 $14686 10 10 5 2500 3000 $5032 L186AT 300 1750 2300 $5994 189AT 3500 3500 $4336 1500 2100 $6464 10 2500 3000 $5032 10 1150 2000 $7318 2110AT 1750 2300 $5994 218AT 219AT 850 1700 $8682 259AT 1500 2100 $6464 650 1600 $10500 288AT 1150 2000 $7318 2110 500 1500 $12556 327AT 850 1700 $8682 259AT 400 1200 $15388 328AT 650 1600 $10500 288AT 300 900 $18376 329AT 500 1500 $12556 327AT 400 1200 $15388 328AT 300 900 $18376 368AT 7.5 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Dim. Pg. Motor Pricing 2300 HP Modifications Pricing 1750 Dim. Pg. Accessories & Modifications Frame ➃ Outline Dimensions Basic List Price* GO-2A Application Information Rated T op Speed RPM Other 1 Base Speed RPM Terms HP General Information Type CD Shunt Wound 2.7 Dripproof Fully Guarded Motors Self-Ventilated and Separately Ventilated General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 240 and 500 Volts Self Ventilated [DPFG] Suitable for constant torque to 60% of base speed 10 Modifications Pricing Motor Pricing HP 20 25 Other Application Information Outline Dimensions Accessories & Modifications 15 30 Terms Type CD Shunt Wound Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A 3500 2500 1750 1500 1150 3500 3000 2300 2100 2000 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 650 500 400 300 250 1700 1600 1500 1200 900 750 3500 3000 2300 2100 2000 1700 1600 1500 1200 900 750 3500 3000 2300 2100 2000 1700 1600 1500 1200 900 750 3500 3000 2300 2100 2000 1700 1600 1500 1200 900 750 3500 3000 2300 2100 2000 1700 1600 1500 1200 900 750 Frame ➃ 240V 500V $5652 $5788 $6874 $7442 $8358 218AT 218AT 219AT • 10 258AT 218AT 219AT • 258AT 258AT $10988 $13514 $16004 $19706 $24742 287AT 327AT 365AT 366AT 368AT 287AT 327AT 365AT 366AT 407AT $6894 $7020 $8332 $9078 $11272 $13442 $16708 $20928 $25324 $31092 218AT 219AT 258AT • 288AT 327AT 365AT 368AT 407AT 409AT 218AT 219AT 258AT • 259AT 288AT 327AT 365AT 368AT 407AT 409AT $8178 $8088 $9600 219AT 258AT 259AT • 219AT 258AT 259AT • $13098 $16068 $19898 $24734 $30074 $37828 327AT 365AT 366AT 368AT 407AT 504AT 327AT• 365AT 366AT 407AT 407AT 508AT $9114 $8974 $11926 258AT 258AT 287AT • 258AT 259AT 287AT • $15074 $18340 $23832 $28350 $34374 $40936 328AT 365AT 368AT 407AT 409AT 504AT 328AT 366AT 368AT 409AT 409AT 508AT $10420 $9864 $13158 287AT 287AT 288AT • 259AT 259AT 288AT • $16678 $20390 $26238 $31454 $37860 $46276 365AT 366AT 407AT 407AT 504AT 506AT 365AT 366AT 407AT 409AT 506AT 508AT 10 10 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. 2.8 www.gemotors.com • 800-541-7191 Dim. Pg. Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Basic List Price* GO-2A Frame ➃ 240V 500V $5652 $5788 $6874 $7442 $8358 218AT 218AT 219AT 218AT 218AT 219AT 258AT 258AT $9990 $12286 $14550 $17916 $21516 $24166 $6894 $7020 $8332 $9078 $10248 $12220 $15190 $18198 $21952 $27036 $30546 $8178 $8088 $9600 $10454 $11908 $14608 $18090 $21508 $26152 $31642 $36496 $9114 $8974 $10842 $11660 $13704 $16674 $20724 $24652 $29890 $35596 $41896 $10420 $9864 $11962 $13012 $15162 $18538 $22816 $27352 $32922 $40240 $50400 287AT 327AT 328AT 329AT 366AT 366AT 218AT 219AT 258AT 10 258AT 10 288AT 327AT 327AT 328AT 366AT 366AT 368AT 219AT 258AT 259AT 10 327AT 328AT 328AT 329AT 366AT 407AT 407AT 258AT 258AT 287AT 10 328AT 328AT 329AT 366AT 368AT 409AT 409AT 287AT 287AT 288AT 10 328AT 329AT 366AT 368AT 407AT 409AT 409AT Dim. Pg. 287AT 327AT 328AT 329AT 368AT 368AT 218AT 219AT 258AT 259AT 288AT 327AT 327AT 329AT 365AT 366AT 409AT 219AT 258AT 259AT 287AT 327AT • 328AT 328AT 329AT 366AT 407AT 10 258AT 259AT 287AT 288AT 328AT• 328AT 329AT 368AT 368AT 409AT 10 259AT 259AT 288AT • 327AT 328AT 329AT 366AT 407AT 407AT 409AT 10 ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. GEP387M 09/11 • Prices and data subject to change without notice. Dripproof Fully Guarded Motors Self-Ventilated and Separately Ventilated Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 240 and 500 Volts 75 100 288AT 328AT • $20774 $25386 $31050 $37474 $44662 $54908 366AT 368AT 409AT 504AT 506AT 508AT 366AT • 368AT • 407AT 504AT 506AT 508AT 10 $15088 $17788 327AT 365AT 288AT 328AT • $23970 $29468 $35708 $42944 $51306 368AT 407AT 504AT 506AT 508AT 368AT • 407AT 409AT 506AT 508AT $20406 $17608 $20406 10 10 365AT 366AT • 328AT 366AT • $27434 $33490 $40210 $48652 $57536 407AT L409AT 504AT 506AT 508AT 368AT • 407AT 504AT 506AT 508AT $24538 $22450 $24028 10 366AT • 365AT 366AT • $32310 $38482 $46966 $56104 L407AT 504AT 506AT 508AT 407AT 504AT 506AT 508AT $30222 $30222 10 368AT 366AT 368AT • $39558 $46420 $56282 L409AT 504AT 508AT 409AT 506AT 508AT 10 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. www.gemotors.com • 800-541-7191 $12004 $11526 $14122 $15598 $18064 $22074 $27000 $32586 $38836 $47746 $56926 $15300 $13716 $16170 $17952 $20844 $25624 $31050 $37342 $44614 $54420 $65250 $18550 $16008 $18550 $20138 $23856 $29122 $34966 $42306 $50032 $60778 $71460 $22308 $20410 $21844 $23176 $28096 $33462 $40840 $48786 $57480 $71586 $79800 $27474 $27474 $29050 $34398 $40366 $48940 $58032 $70398 $84600 $93630 10 10 287AT 328AT 327AT 328AT 366AT 368AT 409AT 407AT 506AT 506AT 288AT 327AT • 328AT 328AT • 366AT 368AT 407AT 409AT 409AT 10 10 10 327AT 328AT 328AT 329AT 368AT 407AT 409AT 506AT 506AT 508AT 288AT 328AT • 329AT 366AT • 368AT 407AT 504AT 409AT 508AT 508AT 10 10 365AT 366AT 328AT L328AT • 366AT 368AT • 368AT 407AT 504AT 506AT 506AT 508AT 368AT 368AT 409AT 409AT 506AT 508AT 508AT 10 10 365AT 366AT 329AT 329AT• 366AT 368AT• 407AT 504AT 506AT 506AT 508AT 368AT 407AT 409AT 506AT 506AT 508AT 5010AY 366AT 368AT 10 L407AT L409AT 506AT 506AT 508AT 5010AY 5010AY Motor Pricing 287AT 287AT 328AT Modifications Pricing $12004 $12678 $15534 Accessories & Modifications 3500 3000 2100 2000 2000 1700 1600 1500 1200 900 750 3500 2700 2100 2000 2000 1700 1600 1500 1200 900 750 3500 2700 2100 2000 2000 1700 1600 1500 1200 900 750 3500 2700 2100 2000 2000 1700 1600 1500 1200 900 750 2700 2000 2000 2000 1700 1600 1500 1200 900 750 Outline Dimensions 60 3500 2500 1750 1500 1150 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 650 500 400 300 250 3500 2500 1750 1500 1150 850 350 500 400 300 250 2500 1750 1500 1150 850 650 500 400 300 250 Application Information 50 Rated Top Speed RPM 10 366AT 368AT • 368AT 407AT • 409AT 506AT 508AT 5010AY 5010AY 6062 Other 40 Base Speed RPM Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Frame ➃ Basic List Price* GO-2A 240V 500V Dim. Pg. Terms HP Self Ventilated [DPFG] Suitable for constant torque to 60% of base speed Frame ➃ Basic List Price* GO-2A 240V 500V Dim. Pg. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. GEP387M 09/11 • Prices and data subject to change without notice. General Information Type CD Shunt Wound 2.9 Dripproof Fully Guarded Motors Self-Ventilated and Separately Ventilated General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 240 and 500 Volts Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing HP 125 150 200 250 Base Speed RPM Rated Top Speed RPM 2500 1750 1500 1150 850 650 500 400 300 250 2500 1750 1500 1150 850 650 500 400 2700 2000 2000 2000 1700 1600 1500 1200 900 750 2700 2000 2000 2000 1700 1600 1500 1200 300 900 1750 1500 1150 850 650 500 400 2000 1900 1800 1700 1600 1500 1200 300 900 1750 1500 1150 850 650 500 400 300 1900 1800 1700 1600 1600 1500 1200 900 Self Ventilated [DPFG] Suitable for constant torque to 60% of base speed Frame ➃ Basic List Price* GO-2A 240V 500V Dim. Pg. $35848 $35848 L407AT 368AT 407AT • $46420 $54400 504AT 506AT 506AT 508AT $43192 $43192 10 L409AT 407AT 409AT $53424 $61590 506AT 508AT 506AT 508AT $54866 504AT 504AT $66198 L508AT 508AT $67534 L506AT 506AT 10 Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Frame ➃ Basic List Price* GO-2A 240V 500V Dim. Pg. $32590 $32590 $34960 $40366 $47304 $56364 $69264 $80700 $95632 $106624 $37558 $37558 $40672 $46456 $53556 $63466 $78234 $88812 L407AT L407AT 10 L409AT 504AT 506AT 508AT 5010AY 5010AY 6160 L407AT L407AT 10 L409AT 506AT 506AT 5010AY 5010AY 368AT 368AT • 407AT 409AT • 506AT 506AT 508AT 5010AY 5010AY 6062 407AT 407AT 409AT 409AT 506AT 506AT 508AT 5010AY $106624 6062 6062 $47710 $51640 $57564 $65652 $77992 $92718 $106782 L409AT L409AT L409AT 506AT 506AT 508AT 6062 6157 10 506AT 508AT 5010AY 6058 6058 $126330 6160 6164 $58726 $62148 $69190 $78130 $88426 $110914 $124290 $145464 L504AT 504AT 506AT 506AT 5010AY 5010AY 6062 6169 6259 10 L508AT 6052 6058 6062 6160 6164 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. Terms Other Application Information Type CD Shunt Wound Dripproof Fully Guarded Separately-Ventilated (DPFG-SV) (Frame CD506AT shown above.) 2.10 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Dripproof Fully Guarded Motors Separately Ventilated Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 500 Volts 500 600 Frame ➃ 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 1900 1800 1600 1500 1500 1300 1200 900 1900 1800 1500 1500 1400 1200 1000 750 1900 1700 1500 1400 1200 1000 1000 $70470 $74906 $81204 $91126 $100846 $121416 $139644 $163024 $98010 $104280 $107730 $117450 $126090 $141840 $166372 $200410 $131130 $134786 $138040 $146814 $153288 $166686 $200544 506AT • 506AT 508AT • 5010AY • 6062 6160 6169 6262 508AT • 5010AY 5010AY • 6062 6160 6259 6262 6266 5010AY • 6055 6058 6160 6164 6262 6266 300 1750 1500 1150 850 650 500 400 750 1900 1700 1500 1300 1200 1000 1000 $228456 $181576 $188510 $201664 $203616 $222928 $248968 $266634 6271 6063 6063 6066 6173 6268 6275 6280 300 750 $290842 6881 500V Dim. Pg. HP 700 800 900 1000 1250 Rated Top Speed RPM Basic List Price* GO-2A Frame ➃ 1750 1500 1150 850 650 500 400 300 1750 1150 850 650 500 400 300 1150 850 650 500 400 300 1150 850 650 500 400 300 250 1150 850 650 500 400 300 1800 1700 1300 1200 1000 1000 1000 750 1750 1250 1000 1000 1000 1000 750 1250 1000 1000 1000 1000 750 1250 1000 1000 1000 1000 750 710 1150 1000 1000 1000 900 750 $206786 $216564 $224164 $226248 $251260 $273780 $291438 $326238 $242216 $247248 $249630 $275346 $296988 $317656 $355582 $276126 $278298 $298690 $318642 $339120 $379612 $299808 $301686 $320878 $342954 $363186 $406548 $462600 $358344 $360222 $379944 $399922 $423514 $474082 6165 500V Dim. Pg. 10 6168 6173 6270 6275 6881 6887 10 6173 6270 6275 6280 6881 6887 6268 6270 6275 6779 6887 6985 6268 6270 6774 6881 6887 6985 6991 6776 6778 6785 6896 6996 10 Terms Other * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. Base Speed RPM Modifications Pricing 400 Basic List Price* GO-2A Accessories & Modifications 300 Rated Top Speed RPM Outline Dimensions HP Base Speed RPM Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Application Information Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Motor Pricing General Information Type CD Shunt Wound www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.11 Dripproof Fully Guarded Motors Separately Ventilated Modifications Pricing Motor Pricing General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 600V Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed HP 25 30 Application Information Outline Dimensions Accessories & Modifications 40 50 60 75 Base Speed RPM Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 $10842 $13704 $16674 $20724 $24652 $29890 $11962 $15162 $18538 $22816 $27352 $32922 $14122 $18064 $22074 $27000 $32586 $38836 $16170 $20844 $25624 $31050 $37342 $44614 $18550 $23856 $29122 $34966 $42306 $50032 $21844 $28096 $33462 $40840 $48786 $57480 287AT 327AT 328AT 600V Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Dim. Pg. HP 100 10 10 10 288AT 328AT 329AT 125 10 10 10 327AT 329AT 368AT 150 10 10 10 328AT 329AT 368AT 200 10 10 10 L328AT 368AT 407AT 250 10 10 10 329AT 368AT 409AT 300 10 10 10 Base Speed RPM Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 $27474 $34398 $40366 $48940 $58032 $70398 $32590 $40366 $47304 $56364 $69264 $80700 $37558 $46456 $53556 $63466 $78234 $88812 $47710 $57564 $65652 $77992 $92718 $106782 $58726 $69190 $78130 $88426 $110914 $124290 $70470 $81204 $91126 $100846 $121416 $139644 368AT 407AT 409AT * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. Terms Other Type CD Shunt Wound 2.12 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 600V 10 10 10 407AT 409AT 506AT 10 10 10 409AT 409AT 506AT 10 10 10 409AT 506AT 508AT 10 10 6062 504AT 508AT 5010AY 10 6062 6160 506AT 5010AY 10 6062 6160 6164 Dim. Pg. Dripproof Fully Guarded Motors Separately Ventilated Class F Insulation For Continuous Operation in 40°C Ambient PRICES - 600V (Type C Power Supply)➁ 800 900 1000 1250 1500 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1150 850 650 500 400 1150 850 650 500 400 1150 850 650 500 400 1150 850 650 500 400 850 650 500 400 $98010 $107730 $117450 $126090 $141840 $166372 $131130 $138040 $146814 $153288 $166686 $200544 $181576 $201664 $203616 $222928 $248968 $266634 $224164 $226248 $251260 $273780 $291438 $247248 $249630 $275346 $296988 $317656 $276126 $278298 $298690 $318642 $339120 $299808 $301686 $320878 $342954 $363186 $360222 $379944 $399922 $423514 508AT 5010AY 6062 6160 6164 6169 6055 6058 6160 6164 6262 6266 6058 6062 6164 6169 6266 6271 6173 6268 6270 6275 6280 6268 6270 6275 6280 6881 6268 6270 6275 6881 6887 6268 6270 6275 6881 6887 6774 6779 6887 6985 1150 1150 $413182 6876 850 650 500 400 850 650 500 400 $413182 $436060 $459172 $486262 6881 6887 6996 6999 Dim. Pg. HP 1750 2000 2250 2500 3000 Rated Top Speed RPM Basic List Price* GO-2A 850 650 500 850 650 500 850 650 850 850 650 500 850 650 500 850 650 850 $465400 $490894 $516912 $582880 $620200 $670020 $634466 $675090 $684470 6890 6996 6999 6896 6996 6999 6896 6999 6990 850 850 $780486 6996 600V Dim. Pg. PRICES - 700V (3 Phase, 6 Controlled Pulse Power Supply)➁ Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed HP 1500 1750 2000 2250 2500 3000 Frame ➃ Rated Top Speed RPM Basic List Price* GO-2A 700V 1150 1150 $413182 6873 850 650 500 450 400 350 850 650 500 450 400 850 650 500 850 650 500 850 650 850 1000 900 850 810 770 720 960 900 800 760 720 900 840 750 850 795 710 850 750 850 $413182 $436060 $459172 $472718 $486262 $527278 $465400 $490894 $516912 $641588 $675292 $582880 $620200 $670020 $634466 $675090 $729320 $684470 $728294 $780486 6876 6881 6981 6985 6985 6991 6881 6990 6996 6999 6999 6896 6996 6999 6896 6996 6999 6996 6999 6996 Base Speed RPM Dim. Pg. Accessories & Modifications 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1750 1150 850 650 500 400 1150 850 650 500 400 1150 850 650 500 400 1150 850 650 500 400 1150 850 650 500 400 850 650 500 400 600V Frame ➃ Base Speed RPM Outline Dimensions 700 Basic List Price* GO-2A Application Information 600 Rated Top Speed RPM * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. Other 500 Frame ➃ Base Speed RPM Terms 400 Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Modifications Pricing Separately Ventilated [DPFG-SV] Suitable for constant torque to 5% of base speed Motor Pricing PRICES - 600V (Type C Power Supply)➁ HP General Information Type CD Shunt Wound www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.13 Totally Enclosed Motors Nonventilated Type CD Shunt Wound PRICES - 240 and 500 Volts TENV Suitable for constant torque to 5% of base speed HP 1 1.5 TENV Suitable for constant torque to 5% of base speed Frame ➃ Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A 240V 500V 1750 1150 850 650 500 400 300 3500 2500 1750 1150 850 650 500 400 2300 2000 1750 1600 1500 1200 900 3500 3000 2300 2000 1700 1600 1500 1200 $3836 $4132 $3958 $6822 $7930 $9096 $9978 $3006 $3088 $3394 $4472 $6360 $7732 $8928 $10458 L182AT • L182AT • 186AT 218AT 219AT 219AT 219AT L182AT L182AT 186AT L186AT 189AT 219AT 258AT 258AT 186AT Dim. Pg. HP 10 10 10 2 10 10 10 10 10 186AT 10 10 10 3 10 10 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. Frame ➃ Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A 240V 500V 3500 2500 1750 1150 850 650 500 400 300 3500 2500 1750 1150 850 650 500 400 300 3500 3000 2300 2000 1700 1600 1500 1200 900 3850 3000 2300 2000 1700 1600 1500 1200 900 $3358 $3710 $4076 $5446 $7008 $8334 $9978 $11670 $14478 $4074 $4520 $5308 $7360 $8350 $9856 $11890 $14982 $17718 186AT 186AT L186AT 189AT 219AT 2110AT 258AT 259AT 327AT L186AT L186AT L186AT 219AT 2110AT 259AT 288AT 288AT 328AT 186AT 186AT L186AT 189AT • 219AT 2110AT 258AT 259AT 327AT L186AT L186AT L186AT 219AT 2110AT 259AT Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient 2.14 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 10 10 10 Dim. Pg. Totally Enclosed Motors Nonventilated, Fan Cooled, Air-Over-Frame Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient General Information Type CD Shunt Wound PRICES - 240 and 500 Volts 10 15 20 Basic List Price* GO-2A 240V 3500 3500 $6110 219AT 10 $6341 186AT 10 2500 1750 1500 1150 850 650 500 400 300 3000 2300 2100 2000 1700 1600 1500 1200 900 $7108 $8664 219AT 2110AT 219AT 2110AT • L186AT 189AT • L186AT 189AT • 218AT $10504 $13552 $16120 $19104 258AT 287AT 288AT 327AT 258AT 287AT $7027 $8174 $9175 $10079 $12080 $15585 $18538 $21970 $26165 3500 3500 $8452 2110AT 10 $8298 L186AT 10 2500 1750 1500 1150 850 650 500 400 300 3500 2500 1750 3000 2300 2100 2000 1700 1600 1500 1200 900 3500 3000 2300 $8664 $10582 2110AT 259AT 2110AT 259AT • 189AT 2110AT • $13452 $16270 $19456 288AT 327AT 365AT 288AT $9720 $9964 $11056 $12169 $15470 $18711 $22374 $27418 $32745 $10854 $11144 $11403 189AT 2110AT • 258AT 259AT 288AT 328AT 366AT 1500 2100 $13119 10 287AT 1150 850 650 500 400 3500 2000 1700 1600 1500 1200 3500 $14902 $17802 $21898 $25928 $31761 $13156 288AT 327AT 365AT 368AT 407AT 258AT 288AT 327AT 365AT 2500 3000 $13496 259AT 1750 1500 1150 850 650 500 400 3500 2500 1750 1500 1150 850 650 500 2300 2100 2000 1700 1600 1500 1200 3500 3000 2300 2100 2000 1700 1600 1500 $14849 $16733 $18264 $21776 $28170 $33741 $40696 $16256 $16675 $17110 $19884 $21218 $27076 $33534 $39868 288AT • $12958 $15480 $19042 $22546 327AT 328AT 366AT 10 10 10 10 327AT 10 366AT 368AT $14982 328AT 328AT $18936 $24496 $29340 368AT 407AT 407AT 366AT 368AT 407AT $18450 366AT 366AT $23544 10 368AT * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating www.gemotors.com • 800-541-7191 240V 10 240V 500V $13858 $17270 $19838 $22822 $26470 259AT 288AT 327AT 365AT 368AT 259AT 366AT 409AT $13936 $17170 $19988 $23174 $27560 $32594 259AT 288AT 328AT 365AT 368AT 407AT 259AT 288AT 328AT 365AT 368AT 409AT $13290 259AT 259AT 288AT 327AT 365AT 368AT 407AT 288AT 327AT 365AT 368AT 407AT 10 $16312 $19198 $22760 $26264 $31738 $14794 10 10 259AT $15090 10 10 288AT • 288AT 328AT 365AT 368AT 407AT 409AT $16266 288AT 288AT $19600 $22654 $28616 $33406 $39508 $17854 $18218 $18596 328AT 365AT 368AT 407AT 409AT 328AT 365AT 358AT 407AT 409AT 10 10 $22168 $27262 $33280 $38788 500V Dim. Pg. Dim. Pg. 10 259AT 288AT 259AT 10 10 365AT 10 10 10 259AT 288AT 328AT 365AT 368AT 407AT 219AT 2110AT 259AT • 328AT 365AT 368AT 407AT 409AT 287AT 288AT 327AT • 10 366AT 368AT 407AT 409AT 10 10 10 Modifications Pricing 10 Dim. Pg. Basic List Price* GO-2A 10 Accessories & Modifications 500V Basic List Price* GO-2A 10 2110AT 259AT • 10 288AT 327AT 327AT 366AT 368AT 407AT 409AT 10 10 327AT 327AT 366AT 358AT 407AT 409AT 366AT 368AT 407AT 409AT ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. GEP387M 09/11 • Prices and data subject to change without notice. Motor Pricing Frame ➃ Rated Top Speed RPM Outline Dimensions 7.5 Frame ➃ Base Speed RPM Application Information 5 Frame ➃ TEAO Suitable for constant torque to 40% of base speed Other HP TEFC Suitable for constant torque to 60% of base speed 2.15 Terms TENV Suitable for constant torque to 5% of base speed Totally Enclosed Motors Nonventilated, Fan Cooled, Air-Over-Frame, Unit Cooled Type CD Shunt Wound PRICES - 240 and 500 Volts TENV Suitable for constant torque to 5% of base speed HP 25 30 Accessories & Modifications Modifications Pricing Motor Pricing General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient Rated Top Speed RPM 2500 3000 1750 1500 1150 850 650 500 400 300 2500 1750 1500 1150 850 650 500 400 300 2500 1750 1500 1150 850 2300 2100 2000 1700 1600 1500 1200 900 3000 2300 2100 2000 1700 1600 1500 1200 900 3000 2300 2100 2000 1700 650 1600 500 400 300 1500 1200 900 Frame ➃ Frame ➃ Basic List Price* GO-2A 240V 500V $22150 368AT 368AT $26880 409AT 407AT $29066 10 TEAO Suitable for constant torque to 40% of base speed 409AT Dim. Pg. Basic List Price* GO-2A 240V 500V Frame ➃ Dim. Pg. Basic List Price* GO-2A 240V 500V $18837 327AT 327AT $20098 327AT 327AT $20097 $21813 $25473 $30912 $38426 328AT • 328AT 328AT 368AT 407AT 409AT $21194 328AT 328AT $25868 $31000 $37534 368AT 407AT 409AT 368AT 407AT 409AT $18082 $19378 $22054 $24442 $29878 $25530 $28212 $30139 $33490 $40924 10 368AT 407AT 409AT 365AT 366AT • 10 407AT 409AT 366AT 368AT • 10 407AT 409AT 365AT 366AT • 365AT 368AT 409AT 366AT 368AT • 366AT 407AT 409AT TEAAC Suitable for constant torque to 5% of base speed $21800 $23096 365AT 366AT 365AT 366AT $28562 $33998 $40900 407AT 409AT 10 368AT 409AT 409AT $25918 $28652 366AT 368AT 366AT 368AT $33242 $39706 407AT 409AT 407AT 409AT $45700 504AT 504AT Frame ➃ Dim. Pg. Basic List Price* GO-2A 240V 500V $50438 $57560 $68454 368AT 407AT 409AT 368AT 407AT 409AT $41346 $55858 $63746 $75674 368AT 368AT 409AT 409AT 368AT 407AT 409AT 508AT $49848 368AT 368AT $65624 $74890 $88646 409AT 409AT 506AT 409AT 506AT 508AT Terms Other Application Information Outline Dimensions 40 Base Speed RPM TEFC Suitable for constant torque to 60% of base speed Totally Enclosed Nonventilated (TENV) (Frame CD328AT shown above.) Totally Enclosed Fan Cooled (TEFC) (Frame CD366AT shown above.) * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suit- 2.16 www.gemotors.com • 800-541-7191 able for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. GEP387M 09/11 • Prices and data subject to change without notice. Dim. Pg. Totally Enclosed Motors Fan Cooled, Air-Over-Frame, Unit Cooled Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient General Information Type CD Shunt Wound PRICES - 240 and 500 Volts 75 100 Basic List Price* GO-2A 240V 500V 1750 2100 $34031 409AT 409AT • 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 2000 2000 1700 1600 1500 1200 900 2100 2000 2000 1700 1600 1500 1200 900 2100 2000 2000 1700 1600 1500 1200 $34456 $38638 10 10 L409AT 409AT 300 900 1750 1500 1150 850 650 500 400 2000 2000 2000 1700 1600 1500 1200 300 900 $37051 $38440 $41283 $43948 409AT 10 409AT 10 409AT • 409AT 409AT 409AT Dim. Pg. Frame ➃ Basic List Price* GO-2A 240V 500V $33712 409AT 409AT $37718 $43070 $51150 L409AT 504AT 506AT 409AT 405AT 506AT $36338 L409AT 409AT $41336 $47964 $56736 504AT 506AT 508AT 504AT 506AT 508AT $40018 L409AT 409AT $45700 $54432 504AT 10 504AT 506AT $45880 506AT 506AT $55830 $62810 10 508AT 10 10 Dim. Pg. Basic List Price* GO-2A 240V $34210 500V Dim. Pg. 366AT $44336 $57630 $74358 $84858 $100222 $37680 368AT 409AT 409AT 506AT 506AT 368AT 4007AT 504AT 506AT 508AT 366AT $40936 $50740 $64880 $82352 $93980 $106758 $42412 368AT 407AT 504AT 504AT 506AT 508AT 368AT 407AT 409AT 504AT 506AT 508AT 366AT $49046 $59850 $75008 $93312 $106448 L407AT L409AT 504AT 506AT 508AT 407AT 409AT 504AT 506AT 508AT $125260 6052 6058 $49454 $55728 $61916 $74050 $90424 $109624 $125104 L407AT L407AT 504AT 506AT 508AT 6055 407AT 407AT 407AT 409AT 506AT 508AT 5010AY $146734 6058 6058 Motor Pricing Rated Top Speed RPM Modifications Pricing 60 Frame ➃ Base Speed RPM Accessories & Modifications 50 Frame ➃ TEAAC Suitable for constant torque to 5% of base speed Outline Dimensions HP TEAO Suitable for constant torque to 40% of base speed Application Information TEFC Suitable for constant torque to 60% of base speed Terms Other * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). • Standard rating ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. Totally Enclosed Air-Over-Frame (TEAO) (Frame CDL506AT shown above.) www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.17 Totally Enclosed Motors Unit Cooled Type CD Shunt Wound PRICES - 500 Volts TEAAC Suitable for constant torque to 5% of base speed HP 125 150 Base Speed RPM Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 2000 2000 2000 1700 1600 1500 1200 900 2000 2000 2000 1700 1600 1500 1200 900 $58594 $66322 $74182 $87346 $104546 $124216 $141756 $165894 $67302 $76458 $85988 $99962 $117698 $137568 $156994 $183392 407AT 409AT 504AT 506AT 21 506AT 21 508AT 21 5010AY 6058 504AT 21 504AT 21 504AT 21 508AT 21 508AT 21 5010AY 6058 6062 500V TEAAC Suitable for constant torque to 5% of base speed Dim. Pg. HP 200 250 Base Speed RPM Rated T op Speed RPM Basic List Price* GO-2A Frame ➃ 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 2000 2000 2000 1700 1600 1500 1200 900 2000 2000 2000 1700 1600 1500 1200 900 $83750 $95692 $108552 $123676 $141900 $161614 $184436 $214830 $106394 $118590 $130058 $145882 $164048 $183126 $208986 $242882 504AT 21 506AT 21 506AT 21 508AT 5010AY 6062 6157 6164 506AT 21 508AT 21 508AT 21 5010AY 5010AY 6062 6169 6259 500V Dim. Pg. * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 21 Totally enclosed Air-to-Air cooled machine provided in “B” size cooler. Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient Totally Enclosed Air-To-Air Cooled (Frame CD6774 shown above.) Terms Other Totally Enclosed Air-To-Air Cooled (TEAAC) (Frame CD506AT shown above.) 2.18 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Totally Enclosed Motors Unit Cooled Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient General Information Type CD Shunt Wound PRICES - 500 and 700 Volts 500 600 700 1750 1900 $129550 506 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 1750 1500 1150 850 650 500 400 300 1800 1600 1500 1600 1300 1200 900 1900 1800 1500 1500 1400 1200 1000 750 1900 1700 1500 1400 1200 1000 1000 750 1900 1700 1500 1300 1200 1000 1000 750 1800 1600 1300 1200 1000 1000 1000 750 $140758 $150754 $166954 $184690 $202812 $231450 $268502 $176754 $184466 $190314 $206562 $222664 $238264 $271908 $314530 $224922 $227516 $228018 $243648 $257420 $269978 $308100 $355602 $280788 $283900 $287014 $305424 $334392 $373452 $406224 $440312 $313748 $316736 $319718 $338134 $367928 $407750 $442850 $480010 508 21 5010AY 5010AY 6062 6160 6169 6262 5010AY 5010AY 5010AY 6062 6160 6259 6262 6266 6055 6058 6058 6160 6164 6262 6266 6271 6063 6063 6063 6173 6268 6275 6280 6881 6165 Frame ➃ Frame ➃ 500V Dim. Pg. 700V Dim. Pg. Basic List Price* GO-2A Frame ➃ 500V Frame ➃ Dim. Pg. 700V Dim. Pg. 21 6062 6164 6169 6262 6266 6271 6160 6169 6262 6266 6271 6887 10 6268 6268 6270 6280 6881 6887 6160 6259 6262 6266 6779 6887 6062 6160 6169 6262 Modifications Pricing $136864 $149210 $171898 $206726 $232074 $144764 $150668 $156216 $172282 $183022 $200786 $240776 $269522 $183394 $186662 $189686 $205952 $214442 $226500 $271004 $302682 $239134 $245142 $251152 $264882 $281404 $308170 $333292 $363532 $269272 $274764 $280632 $295064 $313468 $342226 $368418 $402464 10 10 10 6062 6160 6259 6262 6266 6055 6058 6058 6160 6164 6262 6266 6271 6063 6063 6066 6173 6268 6275 6280 6881 6165 6165 6168 6173 6270 6275 6881 6887 Accessories & Modifications 400 Basic List Price* GO-2A 6062 6164 6169 6262 6266 6271 Outline Dimensions 300 Rated Top Speed RPM 6062 6169 6262 6266 6271 6887 Application Information HP Base Speed RPM TEWAC Suitable for constant torque to 5% of base speed Motor Pricing TEAAC Suitable for constant torque to 5% of base speed 6160 6259 6262 6266 6779 6887 Terms Other * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. 21 Totally enclosed Air-to-Air cooled machine provided in “B” size cooler. Totally Enclosed Air-To-Air Cooled (Frame CD6160 shown above.) www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.19 Totally Enclosed Motors Unit Cooled Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 500 and 700 Volts TEAAC Suitable for constant torque to 5% of base speed HP 800 900 1000 1250 1500 1750 2000 2250 3000 TEWAC Suitable for constant torque to 5% of base speed Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A 1150 1250 $351042 6268 6268 $308954 6268 6268 850 650 500 400 300 1150 850 650 500 400 300 1150 850 650 500 400 300 1150 850 650 500 400 850 650 500 400 850 650 500 850 650 500 850 650 500 850 650 850 1200 1000 1000 1000 750 1250 1000 1000 1000 1000 750 1250 1000 1000 1000 1000 750 1150 1000 1000 1000 1000 900 900 850 770 900 900 800 900 840 750 850 795 710 850 750 850 $369286 $399686 $439998 $477234 $517280 $381212 $399138 $429964 $470552 $509772 $552550 $410390 $427882 $458988 $499676 $540756 $586132 $479772 $495774 $527092 $567450 $612732 $559170 $590172 $629594 $678598 $619054 $649360 $687416 $757744 $806260 $871026 $818998 $867340 $931512 $877976 $925890 $990246 6270 6275 6779 6881 6887 6268 6270 6774 6779 6887 6985 6270 6275 6774 6881 6887 6985 6776 6778 6785 6896 6996 6270 6275 6280 6881 6887 6268 6270 6275 6779 6881 6985 6268 6275 6779 6881 6887 6985 $323974 $344182 $374756 $401824 $439544 $336296 $351816 $373762 $406004 $433794 $475076 $362800 $378744 $402370 $436160 $464544 $509288 $426032 $442776 $470394 $507628 $537054 $503050 $534428 $574630 $604624 $560368 $595322 $638134 $699456 $744240 $804024 $759568 $808202 $871070 $817706 $870062 $929018 6270 6275 6779 6881 6887 6268 6270 6774 6779 6887 6985 6270 6275 6774 6881 6887 6985 6776 6778 6785 6896 6996 6270 6275 6280 6881 6887 6268 6270 6275 6779 6881 6985 6268 6275 6779 6881 6887 6985 Frame ➃ Frame ➃ 500V Dim. Pg. 700V 6977 6977 6981 6985 6881 6887 10 10 6881 6990 6996 6896 6996 6999 6896 6996 6999 6996 6999 6999 Dim. Pg. Basic List Price* GO-2A Frame ➃ 500V Frame ➃ Dim. Pg. 700V Dim. Pg. 6977 6977 6981 6985 6881 6887 10 10 6881 6990 6996 6896 6996 6999 6896 6996 6999 6996 6999 6999 * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. Terms Other Type CD Shunt Wound Totally Enclosed Water-To-Air Cooled (Frame CD6160 shown above.) 2.20 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Totally Enclosed 30 Minute Rating Motors Nonventilated 14 Class F Insulation Type C Power Supply➁ For Operation in 40°C Ambient PRICES - 240 and 500 Volts 7.5 10 15 20 25 30 500V 240V 500V 1750 1150 850 1750 1150 850 1750 1150 850 1750 1150 850 650 1750 1150 2300 2000 1700 2300 2000 1700 2300 2000 1700 2300 2000 1700 1600 2300 2000 $2198 $2476 $3202 $2468 $2882 $4300 $2726 $3346 $4848 $3304 $4740 $5778 $6820 $4914 $6064 L182AT L182AT 186AT L182AT L182AT 186AT L182AT L186AT 189AT 186AT 189AT 219AT 2110AT L186AT 219AT 10 1750 1150 850 650 1750 1150 850 650 1750 1150 850 650 1750 1150 850 2100 2000 1700 1600 2100 2000 1700 1600 2100 2000 1700 1600 2100 2000 1700 $14122 $18064 $22074 $27000 $16170 $20844 $25624 $31050 $18550 $23856 $29122 $34966 $21844 $28096 $33462 365AT 366AT 366AT 407AT 365AT 366AT 368AT 407AT 366AT 368AT 407AT 409AT 366AT 407AT L409AT 365AT 365AT 366AT 368AT 365AT 366AT 368AT 407AT 366AT 368AT 407AT 409AT 366AT 407AT 409AT 850 650 1750 1150 850 650 1750 1150 1700 1600 2300 2000 1700 1600 2300 2000 $7264 $8746 $5994 $7318 $8682 $10500 $6874 $8358 2110AT 259AT 2110AT 258AT 259AT 288AT 2110AT 259AT 650 1750 1150 850 650 1750 1150 850 1600 2000 2000 1700 1600 2000 2000 1700 $40840 $27474 $34398 $40366 $48940 $32590 $40366 $47304 504AT 368AT L407AT 504AT 506AT L407AT L409AT 506AT 409AT 368AT 407AT 409AT 506AT 407AT 409AT 506AT 2110AT 259AT 850 1700 $9990 288AT 650 1750 1150 850 650 1750 1150 850 650 1750 1150 850 650 1750 1150 850 650 1600 2300 2000 1700 1600 2300 2000 1700 1600 2300 2000 1700 1600 2300 2000 1700 1600 $12286 $8332 $10248 $12220 $15190 $9600 $11908 $14608 $18090 $10842 $13704 $16674 $20724 $11962 $15162 $18538 $22816 328AT 259AT 288AT 327AT 365AT 288AT 328AT 365AT 365AT 327AT 365AT 365AT 366AT 328AT 365AT 366AT 368AT 288AT 650 1600 $56364 508AT 508AT 328AT 259AT 288AT 327AT 365AT 288AT 328AT 365AT 365AT 327AT 365AT 365AT 366AT 328AT 365AT 366AT 368AT 1750 1150 850 650 1750 1150 850 1750 1150 1750 1150 1750 2000 2000 1700 1600 2000 1800 1700 1900 1700 1900 1600 1900 $37558 $46456 $53556 $63466 $47710 $57564 $65652 $58726 $69190 $70470 $81204 $98010 L409AT 504AT 506AT 508AT 504AT 506AT 508AT L506AT L508AT L506AT L508AT 409AT 506AT 508AT 508AT 504AT 506AT 508AT 506AT 508AT 506AT 508AT 508AT 10 10 Dim. Pg. HP 40 10 10 10 10 50 10 10 10 10 60 10 10 10 10 75 10 10 2110AT 258AT 100 10 10 125 150 200 250 300 400 10 Dim. Pg. Motor Pricing 240V Frame ➃ Modifications Pricing 5 Basic List Price* GO-2A Accessories & Modifications 3 Rated Top Speed RPM Outline Dimensions 2 Base Speed RPM Frame ➃ * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. 14 The NEMA definition for short time rated motors is as follows “All short time ratings are based upon a corresponding short time load test, which shall commence only when the windings and other parts of the machine are within 5°C of the ambient temperature at the time of starting the test.” This means that field voltage should be removed when the motor is not operating. These short time rated motors have 150% occasionally repeated overload capability at all speeds within the standard speed range. To add for wider than standard speed range, use rated HP and the tables in page__ item __ (frame size may be different from standard). Application Information 1.5 Basic List Price* GO-2A Other 1 Rated Top Speed RPM Terms HP Base Speed RPM General Information Type CD Shunt Wound www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2.21 Totally Enclosed 60 Minute Rating Motors Nonventilated 14 General Information Class F Insulation Type C Power Supply➁ For Operation in 40°C Ambient PRICES - 240 and 500 Volts Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing HP 1 1.5 2 3 5 7.5 10 15 20 25 Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A 240V 500V Dim. Pg. 10 1750 2300 $15502 365AT 328AT a 10 30 1150 850 650 1750 2000 1700 1600 2100 $19552 $23902 $29424 $19624 366AT 366AT 407AT 366AT 365AT 366AT 368AT 365AT 40 1150 850 650 1750 2000 1700 1600 2100 $23296 $28468 $33264 $23672 366AT 368AT 407AT 366AT 366AT 368AT 407AT 366AT 50 1150 850 650 1750 1150 850 2000 1700 1600 2100 2000 1700 $26878 $31160 $37256 $25774 $29772 $34712 368AT 407AT 409AT 368AT 407AT 504AT 368AT 407AT 409AT 366AT 407AT 409AT 10 650 1600 $41728 504AT 409AT 10 1750 1150 850 650 1750 1150 850 2100 2000 1700 1600 2000 2000 1700 $28718 $33264 $39886 $47728 $33408 $41004 $46588 368AT L407AT 504AT 506AT L407AT 409AT 506AT 368AT 407AT 504AT 506AT 407AT 409AT 506AT 650 1600 $56376 508AT 508AT 1750 1150 850 650 1750 1150 850 1750 1150 2000 2000 1700 1600 2000 2000 1700 2000 1800 $37544 $46588 $54388 $64928 $43270 $53392 $61736 $54856 $66448 L409AT 504AT 506AT 508AT L506AT 506AT 508AT L508AT L508AT 409AT 506AT 508AT 508AT 504AT 506AT 508AT 508AT 508AT Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A 240V 500V 1750 1150 850 650 1750 1150 850 650 1750 1150 850 650 1750 1150 850 2300 2000 1700 1600 2300 2000 1700 1600 2300 2000 1700 1600 2300 2000 1700 $2268 $2686 $3166 $5456 $2714 $3576 $5088 $6186 $3260 $4356 $5606 $6650 $4246 $5888 $6680 L182AT L182AT 186AT L186 L182AT L182AT 186AT 218AT L182AT L186AT 189AT 219AT 186AT 189AT 219AT 650 1750 1150 850 650 1750 1150 850 1600 2300 2000 1700 1600 2300 2000 1700 $7884 $5686 $7010 $8402 $10840 $6930 $8464 $10760 2110AT 189AT 258AT 259AT 259AT 2110AT 258AT 288AT 10 650 1600 $13016 328AT 328AT 1750 1150 850 650 1750 1150 850 650 1750 1150 850 650 1750 1150 850 650 2300 2000 1700 1600 2300 2000 1700 1600 2300 2000 1700 1600 2300 2000 1700 1600 $7948 $10364 $12384 $15232 $10328 $12704 $15148 $19596 $11902 $14760 $18834 $23328 $13980 $17720 $21504 $26730 258AT 259AT 288AT 328AT 288AT 328AT 365AT 365AT 327AT 365AT 365AT 366AT 328AT 365AT 366AT 368AT 2110AT 259AT 327AT 328AT 288AT 328AT 366AT 365AT 327AT 365AT 366AT 366AT 328AT 365AT 366AT 368AT Frame ➃ 10 Dim. Pg. HP 10 10 10 10 10 10 10 10 10 10 10 10 259AT 259AT 2110AT 259AT 288AT 60 75 100 125 150 200 Frame ➃ * Basic list price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modifications section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. 14 The NEMA definition for short time rated motors is as follows “All short time ratings are based upon a corresponding short time load test, which shall commence only when the windings and other parts of the machine are within 5°C of the ambient temperature at the time of starting the test.” This means that field voltage should be removed when the motor is not operating. These short time rated motors have 150% occasionally repeated overload capability at all speeds within the standard speed range. To add for wider than standard speed range, use rated HP and the tables in page__ item __ (frame size may be different from standard). a 365AT page ___; 328AT page ___. Terms Other Application Information Type CD Shunt Wound 2.22 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Explosionproof and Dust-Ignitionproof Motors Nonventilateda nd Fan Cooled Class F Insulation For Continuous Operation in 40°C Ambient General Information Type CD Shunt Wound UL File #29056 CSA File #056228 Class I Group D Class II Group E, F, G - See Page XX 5 1750 1150 2500 1750 1150 2500 1750 1150 2500 1750 1150 2500 1750 1150 2050 1380 2750 2050 1380 2750 2050 1380 2750 2050 1380 2750 2050 1380 $8082 $8457 $8568 $8790 $9609 $9162 $9927 $11085 $10674 $11916 $16776 $14061 $17058 $19719 TENV TENV TENV TENV TENV TENV TENV TEFC TEFC TEFC TENV TENV TENV TEFC 188AT 188AT 188AT 189AT 189AT 189AT 189AT 189AT 189AT 189AT 2110AT 2110AT 2110AT 2110AT Dim. Pg. HP 1 1.5 2 3 5 7.5 10 Totally Enclosed Fan Cooled Explosionproof (TEFC-XP) (Frame CD409AT shown above.) * Basic List price applies to frames listed. It does not include pricing for modifications or accessories. Refer to Modification section for appropriate list price addition(s). ➁ For Suitability of operation with rectified power supplies, see page xx. ➃† Standard shaft for frames CDL188AT-CD409AT is suitable for belt drive or direct coupling (within limits given in Application Section.) ➅ TENV-Totally Enclosed Nonventilated TEFC- Totally Enclosed Fan Cooled 10 Refer to GE for frame. 15 UL Operating Temperature Code T4-135 C. 15 20 25 30 40 50 60 75 www.gemotors.com • 800-541-7191 1750 1150 850 2500 1750 1150 850 3500 2500 1750 1150 850 3500 2500 1750 1150 850 3500 2500 1750 1150 850 3500 2500 1750 1150 850 3500 2500 1750 1150 850 3500 2500 1750 1150 850 2500 1750 1150 850 2500 1750 1150 850 1750 1150 850 1750 1150 850 1750 1150 1750 1750 2300 2000 1700 3000 2300 2000 1700 3850 3000 2300 2000 1700 3850 3000 2300 2000 1700 3850 3000 2300 2000 1700 3500 3000 2300 2000 1700 3500 3000 2300 2000 1700 3500 3000 2300 2000 1700 3000 2300 2000 1700 3000 2300 2000 1700 2300 2000 1700 2100 2000 1700 2100 2000 2100 2100 $8082 $8457 $10635 $8568 $8790 $9609 $14310 $8316 $9162 $9927 $11085 $15768 $9393 $10674 $11916 $16776 $18789 $12057 $14061 $17058 $19719 $23634 $16452 $18732 $19491 $23811 $30267 $19821 $20868 $21399 $27684 $31158 $25740 $25173 $27618 $33300 $39765 $31101 $31794 $38745 $49443 $35133 $35691 $46512 $56448 $40695 $51327 $62745 $51516 $61155 $74730 $62145 $70557 $67659 $75387 Frame ➃† Enclosure ➅ 240V 500V TENV TENV TENV TENV TENV TENV TENV TENV TENV TENV TEFC TENV TENV TEFC TEFC TENV TENV TENV TENV TENV TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC 188AT 188AT 188AT 188AT 189AT 189AT 2110AT 188AT 189AT 189AT 189AT 2110AT 189AT 189AT 189AT 2110AT 2110AT 2110AT 2110AT 2110AT 2110AT 288AT 2110AT 2110AT 2110AT 288AT 288AT 2110AT 2110AT 288AT 288AT 328AT 288AT 288AT 288AT 328AT 407AT 288AT 328AT 407AT 407AT 288AT 328AT 407AT 407AT 407AT 407AT 409AT 407AT 407AT 409AT 409AT 409AT 409AT 188AT 409AT GEP387L 09/11 • Prices and data subject to change without notice. 15 Dim. Pg. 10 Motor Pricing Frame ➃† Basic List Price* GO-2X 10 10 189AT Modifications Pricing 3 ➅ Rated Top Speed RPM 10 10 10 189AT 189AT 189AT 2110AT 10 Accessories & Modifications 2 Enclosure Base Speed RPM 189AT 189AT 2110AT 2110AT 10 2110AT 2110AT 2110AT 288AT 10 Outline Dimensions 1.5 Basic List Price* GO-2X 2110AT 2110AT 288AT 288AT 10 2110AT 288AT 288AT 328AT Application Information 1 Rated Top Speed RPM 10 288AT 288AT 328AT 10 288AT 328AT 10 10 288AT 328AT Other HP Base Speed RPM PRICES - 240 and 500 Volts (Type C Power Supply➁) 10 10 10 10 10 10 10 Terms PRICES - 180 Volts (Type K Power Supply➁) 10 10 10 10 10 2.23 Explosionproof and Dust-Ignitionproof Motors Nonventilateda nd Fan Cooled Type CD Shunt Wound All listed explosionproof motors meet UL operating temperature code T4A-120°C, except 75 HP, 1750 TEFC, CD409AT frame which is UL operating temperature code T4-135°C. For 120 volt motor, see page XX, Item XX, special armature voltage. See page XX for standard explosionproof outlines. A thermostat with a normally closed contact is included as standard. For Class II, Groups E, F, and G (Division 1 & 2), UL listed motors in frames CD180AT-CD409AT, add $675 GO-2X. For TEAO explosionproof, add $6612 GO-2X (CD407AT and CD409AT frames only). For CSA approval on explosionproof motors, add as follows: GO-2X Frame GO-2X $669 CD320AT $1338 CD210AT $936 CD400AT $1524 CD280AT $1071 Modifications Pricing Frame CD180AT NOTE: Special conduit box and nameplates are required on CSA approved motors. Accessories & Modifications Motor Pricing General Information Class F Insulation For Continuous Operation in -25°C to 40°C Ambient ACCESSORIES: Explosionproof motors are available only with the accessories listed below. An accessory mounting face is available. Contact GE for suitability and availability of accessory mounting options. Application Information Outline Dimensions Brakes Breather Drains Drain holes are normally selected to provide drainage of moisture that might collect at the lowest point of the motor. Explosionproof enclosures, as standard, do not have drain holes. The breather drain is approved for this enclosure when properly maintained after installation. Add $510 GO-2X per drain. Other Not available on explosionproof motors. Shaft Extensions Oversize shaft extensions are not available on explosionproof motors. Space Heaters Terms For heaters installed and leads brought out through the motor conduit box, add $546 GO-2X. 2.24 www.gemotors.com • 800-541-7191 For explosionproof (Class 1, Group D, Class II, Groups E, F, and G) motor-mounted tachometer, add as follows: GE will not mount non-explosionproof tachometers on explosionproof motors. GO-2X Explosionproof brake. Refer to GE. NOTE: These are not available with a thru shaft. Precision Balance Tachometers BC42 (50V/1000RPM) or (100V/1000RPM) $10400 Dynapar X25 (5VDC to 15 VDC Max) (240, 512, 600, 1024, 1200, 2048 PPR) Only suitable for installation in Class 1, Group D environments $4080 For other options, refer to GE. Mounting kit only for BC tach for explosionproof motor (included as part of tachometer price). Kit includes adapter, coupling, stub shaft, and mounting bracket for BC tachometers. Mounting kit is assembled to motor $1806 For mounting only of customer-supplied explosionproof tachometer. This includes coupling, stub shaft, mounting bracket, and assembly of tachometer. $3269 Other accessories are available. Accessories and modifications may be added only when they do not affect the explosionproof features of the motor. All accessories must meet or exceed environment class and group requirements as defined by the National Electrical Code and Underwriters’ Laboratories. Refer to GE. Note: A double shaft extension is not available on explosionproof BC tachometers. The motors described in this section have been listed by Underwriters’ Laboratories for application in hazardous locations of the classes and groups referred to. GEP387L 09/11 • Prices and data subject to change without notice. Explosionproof and Dust-Ignitionproof Motors Purged/Totally Enclosed Separately Ventilated for Hazardous Locations Class F Insulation For Continuous Operation in 40°C Ambient Class II Section 502-8 of the National Electrical Code permits the use of enclosed separately ventilated motors with air ducted-in, air ducted-out ventilation for use in Class II, Division 1 and 2 locations, provided that the maximum surface temperatures shall not exceed 120°C, (248°F). Auxiliary equipment such as a conduit box, tachometer, and other auxiliary devices mounted on the motor must be of the explosionproof type for Division 1 locations. Sealed leads and standard conduit box may be used for Division 2 locations. Separate ventilation in hazardous locations is not available in CD180AT. SUMMARY OF MOTOR REQUIREMENTS FOR SEPARATELY VENTILATED MOTORS IN HAZARDOUS LOCATION MOTOR LEADS CONDUIT BOX TACHOMETERS SPACE HEATERS AUXILIARY DEVICES DIVISION 1 SEALED XP XP LOW TEMP XP DIVISION 2 SEALED STANDARD XP LOW TEMP XP DIVISION 1 SEALED XP XP LOW TEMP XP DIVISION 2 SEALED STANDARD XP LOW TEMP XP Motor Pricing Outline Dimensions CLASS I Modifications Pricing Section 501-8 of the National Electrical Code permits the use of enclosed separately ventilated motors with air ducted-in, air ducted-out ventilation in Class I, Division 1 or 2 locations when installation and operation conform to certain requirements. Motors must be air-purged with a source of clean air and have the control arranged to prevent energization of the machine, until ventilation has been established and the enclosure has been purged with at least 10 volumes of air. Protective devices such as a thermostat must be utilized on the motor to detect any increase in temperature of the motor beyond the design limits, and the control must be arranged to automatically de-energize the equipment. Motor leads must be sealed at the frame exit (see Section 501-5 of the National Electrical Code). Auxiliary equipment such as a conduit box, tachometer, and other auxiliary devices mounted on the motor must be of the explosionproof type for Division 1 locations. Sealed leads and standard conduit box may be used for Division 2 locations. Accessories & Modifications Class I General Information Type CD Shunt Wound CLASS II Application Information XP=Explosionproof rated for hazardous location where motor is used Terms Other WARNING: Enclosed separately ventilated motors supplied for use in a hazardous location do not have an Underwriters’ listing and are not explosionproof. Articles 501-8 and 502-8 of the National Electrical Code governing the installation of motors in Class I and Class II locations assign approval of the installation to “the authority having jurisdiction” (see Article 100 - Definitions of the NEC). Therefore, it is the responsibility of the customer to be familiar with the NEC and the local jurisdictional requirements, and to determine that the motor selection (including possibly permissible alternative ventilation systems or accessories) is “acceptable to the authority having jurisdiction.” www.gemotors.com • 800-541-7191 GEP387L 09/11 • Prices and data subject to change without notice. 2.25 Papermill Duty Totally Enclosed Nonventilated GE produces DC motors designed specifically for papermill PRICES - 500 Volts (Type C Power Supply➁) applications. These ratings are available in Splashproof Fully Suitable for constant torque to 5% of base speed Guarded Separately Ventilated (SPFG-SV) or Totally Enclosed F Rise B Rise Nonventilated (TENV) enclosures. The pricing includes Frame Frame Rated Basic Basic standard papermill features listed below. Other modifications ➃ ➃ Base Top List List Speed Speed Price* Price* may be specified. Refer to the Accessories and Modifications HP RPM RPM GO-2A 500V GO-2A 500V section for price adders. 1750 2300 218AT 218AT $7170 $8186 Frames are listed for Class F temperature rise and Class B temperature rise. Class F rise motors are rated at 1.0 Service Factor (SF) and 150% occasional overload. Class B rise motors are rated at 1.0 SF and 200% occasional overload, Class F rise at 1.15 SF and 150% occasional overload. Class F or Class B rise must be specified at the time of order. Other combinations available and must be specified at the time of order. All frames listed include 40°C ambient, continuous duty, and 240/120V or 300/150V shunt field. Voltage must be specified at the time of order. Ratings up to and including 1250 HP are 500V armature. Ratings 1500 HP and above are 700V armature. 2 3 5 7.5 10 15 1150 1750 1150 1750 1150 1750 1150 1750 1150 1750 1150 2000 2300 2000 2300 2000 2300 2000 2300 2000 2300 2000 $8540 $8402 $10454 $11758 $14062 $14140 $17010 $16516 $19038 $19440 $23292 218AT 218AT 219AT 2110AT 258AT 259AT 288AT 327AT 328AT 328AT 366AT $9900 $9726 $12486 $13922 $16688 $16786 $20374 $19756 $22908 $23410 $28026 Dim. Pg. 219AT 218AT 258AT 2110AT 259AT 259AT 327AT 327AT 328AT 328AT 368AT * Basic list price applies to frames listed. Refer to Modification section for appropriate list price addition(s). ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section). Frames CD6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. Refer to GE for backstand or unwind applications. Standard papermill features include: • Transparent cover (Lexan® or equivalent) located on the conduit box side of the motor. • Cast iron endshields on frames CD210AT-CD508AT • Shaft grounding brush • One normally opened and one normally closed thermostat • Drive end labyrinth seal • Oversize conduit box • Waterproof conduit box on frames CD218AT-CD5010AY • Special brushes • Splashproof Fully Guarded Separately Ventilated (SPFG-SV) or Totally Enclosed Nonventilated (TENV) enclosure • Air entry in drive end on separately ventilated machine Splashproof Fully Guarded Self Ventilated (SPFG-SV) (Frame CD328AT shown at right.) ® Registered trademark of General Electric Company. Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Class F Insulation For Continuous Operation in 40°C Ambient 2.26 www.gemotors.com • 800-541-7191 GEP387L 09/11 • Prices and data subject to change without notice. Papermill Duty Suitable for constant torque to 5% of base speed 15 20 25 30 40 $9724 $11048 218AT 2110AT 850 1700 $12604 259AT $14774 10 650 500 400 300 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 1600 1500 1200 900 2300 2000 1700 1600 1500 1200 900 750 2300 2000 1700 1600 1500 1200 900 750 2300 2000 1700 1600 1500 1200 900 750 2300 2000 1700 1600 1500 1200 900 750 2300 2000 1700 1600 1500 1200 900 750 2100 2000 1700 1600 1500 1200 900 $14868 $16924 $20554 $23542 $10604 $12280 $14358 $16654 $18918 $23082 $26682 $29332 $12254 $14616 $16588 $20356 $23364 $27118 $32202 $35712 $13522 $16276 $18976 $23256 $26674 $31318 $36808 $41662 $15210 $18072 $21840 $25890 $29818 $35056 $40762 $47062 $16330 $19530 $23704 $27982 $32518 $38088 $45406 $55566 $18490 $23230 $27240 $32166 $37752 $44002 $52912 288AT 327AT 328AT 368AT 219AT 258AT 287AT 327AT 328AT 329AT 368AT 368AT 258AT 288AT 327AT 327AT 329AT 365AT 366AT 409AT 259AT 327AT 328AT 328AT 329AT 366AT 407AT $17492 $20060 $24398 $28134 $12320 $14366 $16854 $19724 $23352 $27558 $32058 $35372 $14336 $17176 $19642 $24152 $27910 $32604 $38958 $43346 $15922 $19250 $22626 $27778 $32048 $37854 $44718 $50784 $17920 $21496 $26006 $31070 $35980 $42528 $49658 $57534 $19320 $23320 $28336 $33684 $39354 $46318 $55466 $68166 $22020 $27744 $32756 $38916 $45896 $53708 $64846 288AT 327AT 328AT 368AT 2110AT 10 10 288AT 328AT 329AT 366AT 407AT 407AT 10 327AT 327AT 328AT 366AT 368AT 407AT 409AT 409AT www.gemotors.com • $11220 $13066 218AT 258AT 800-541-7191 500V F Rise, 150% O.L. Dim. Pg. HP 50 10 327AT 328AT 365AT 329AT 368AT 60 10 259AT 288AT 327AT 328AT 329AT 75 10 407AT 10 259AT 327AT 328AT 328AT 329AT 407AT 409AT 100 10 288AT 328AT 328AT 10 407AT 407AT 125 10 10 288AT 328AT 329AT 368AT 407AT 10 10 10 327AT 329AT 368AT 407AT 504AT 506AT 508AT 150 Base Speed RPM 1750 1150 850 650 500 400 300 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 Rated Top Speed RPM Basic List Price* GO-2A Frame ➃ 2100 2000 1700 1600 1500 1200 900 2100 2000 1700 1600 1500 1200 900 750 2100 2000 1700 1600 1500 1200 900 750 2000 2000 1700 1600 1500 1200 900 750 2000 2000 1700 1600 1500 1200 900 750 2000 2000 1700 1600 $20538 $26010 $30790 $36216 $42508 $49780 $59586 $23736 $29022 $34288 $40132 $47472 $55198 $65944 $77300 $27010 $33262 $38628 $46006 $53952 $62646 $77426 $86770 $32640 $39564 $45532 $54106 $63198 $76238 $90440 $100600 $37756 $45532 $52470 $61530 $75104 $86540 $101472 $113594 $42724 $51622 $58722 $69306 $84074 $94652 $113594 $126640 328AT 329AT 368AT 368AT 504AT 409AT 508AT L328AT 368AT 368AT 407AT 504AT 506AT 506AT 508AT 329AT 368AT 407AT 504AT 506AT 506AT 508AT a b c 500 500V 10 368AT 407AT 409AT 506AT 508AT 5010AY 5010AY 6062 368AT 409AT 506AT 506AT 508AT 5010AY 6062 407AT 407AT 409AT 506AT 506AT 508AT 5010AY 6062 10 B Rise, 200% O.L. Dim. Pg. Basic List Price* GO-2A Frame ➃ $24580 $31220 $37194 $43978 $51842 $60932 $73190 $28352 $34984 $41568 $48872 $58046 $67704 $81136 $96294 $32470 $40248 $46992 $56216 $66146 $77016 $95320 $106720 $39506 $48160 $55622 $66340 $77704 $93834 $112720 $124006 $45902 $55622 $64294 $75620 $92418 $106714 $125378 $140248 $52110 $63234 $72108 $85170 $103630 $116854 $140248 $156556 328AT 368AT 407AT 504AT 504AT 506AT 508AT 329AT 368AT 407AT 504AT 500V Dim. Pg. Modifications Pricing 2300 2000 287AT 328AT 328AT 329AT 368AT 368AT 409AT Frame ➃ 10 508AT 10 10 368AT 368AT 409AT 504AT 508AT 5010AY Accessories & Modifications 10 1750 1150 Dim. Pg. 500V Basic List Price* GO-2A 10 10 368AT 409AT 409AT 506AT 508AT 5010AY 6058 6062 407AT 409AT 506AT 506AT 508AT 5010AY 5010AY Outline Dimensions 7.5 Base Speed RPM Frame ➃ Application Information HP B Rise, 200% O.L. Basic List Price* GO-2A 10 L409AT 506AT 506AT 508AT 5010AY 5010AY 6062 Other F Rise, 150% O.L. Rated Top Speed RPM 10 * Basic list price applies to frames listed. Prices include standard papermill features listed on page XX. Refer to Modification section for other accessories and modifications. ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section Frames CD 6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. a Top speed; Class F rise=1500, Class B rise=1000 b Top speed; Class F rise=1200, Class B rise=1000 c Top speed; Class F rise=900, Class B rise=800 GEP387L 09/11 • Prices and data subject to change without notice. Motor Pricing PRICES - 500 Volts 2.27 Terms Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient General Information Splashproof Fully Guarded Separately Ventilated Papermill Duty Splashproof Fully Guarded Separately Ventilated Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Class F Insulation Type C Power Supply➁ For Continuous Operation in 40°C Ambient PRICES - 500 Volts PRICES - 500 Volts Suitable for constant torque to 5% of base speed Suitable for constant torque to 5% of base speed F Rise, 150% O.L. HP 200 250 300 400 Terms Other Application Information 500 600 700 Base Speed RPM 1750 1150 850 650 500 400 300 250 1750 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 Rated Top Speed RPM Basic List Price* GO-2A Frame ➃ 2000 1800 1700 1300 1500 1200 $52876 $62730 $71492 $83832 $99688 $113752 $133300 $150340 $63892 $69030 $83970 $94266 $117884 $131260 $152434 $171910 $87044 $96966 $107816 $128386 $146614 $169994 $191980 $113570 $124420 $133060 $148810 $173342 $207380 $228790 $145010 $153784 $160258 $173656 $207514 $235682 $263426 $208634 $210586 $229898 $255938 $273604 $298068 $334526 $231134 $233218 $258230 $280750 $298664 $333464 $374726 L409AT 506AT 506AT 508AT 6062 6165 6164 504AT 504AT 506AT 5010AY 5010AY 6062 6169 6259 d 750 1900 1700 1600 1600 1500 1200 900 750 1600 1500 1500 1300 1200 900 750 1500 1500 1400 1200 1000 750 710 1500 1400 1200 1000 1000 750 710 1500 1300 1200 1000 1000 750 710 1300 1200 1000 1000 1000 750 710 B Rise, 200% O.L. Dim. Pg. 500V 10 508AT 5010AY 6062 6160 6169 6262 5010AY 6062 6160 6259 6262 6266 6058 6160 6164 6262 6266 6271 6066 6173 6268 6275 6280 6881 6168 6173 6270 6275 6881 6887 10 Basic List Price* GO-2A Frame ➃ $124802 $77120 $87904 $104458 $122864 $140446 $164882 $186182 $78572 $92326 $109502 $117500 $145610 $162332 $188798 $213144 $107344 $119746 $133026 $158738 $181524 $210748 $238232 $141632 $153782 $164582 $184270 $214934 $257482 $284244 $179520 $190486 $198578 $215326 $257648 $292794 $327476 $238882 $241126 $263336 $293282 $313596 $341694 $383620 $264758 $267154 $295918 $322072 $342376 $382396 $429850 L409AT 506AT 5010AY 6058 6062 6169 6169 500V F Rise, 150% O.L. Dim. Pg. 800 10 506AT 508AT 5010AY 6062 6062 6169 6262 900 10 1000 5010AY 5010AY 6062 6160 6169 6262 1250 6058 6160 6164 6262 6266 6271 www.gemotors.com • 800-541-7191 Basic List Price* GO-2A Frame ➃ 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 1150 850 650 500 400 300 250 1150 850 650 500 400 300 1250 1000 1000 1000 1000 750 710 1250 1000 1000 1000 1000 750 710 1250 1000 1000 1000 1000 750 710 1150 1000 1000 1000 900 750 $254218 $256600 $282316 $304214 $324882 $362808 $406226 $283096 $285268 $305916 $325874 $346346 $386838 $439002 $307034 $308656 $328104 $350180 $370412 $414450 $470502 $365570 $367448 $387170 $407148 $431396 $481984 6173 6270 6275 6280 6881 6887 500V B Rise, 200% O.L. Dim. Pg. 10 6268 6270 6275 6779 6887 6985 10 6268 6270 6774 6881 6887 6985 6991 6776 6778 6785 6896 6996 10 Basic List Price* GO-2A Frame ➃ $291560 $294298 $323872 $348760 $372528 $416144 $466076 $324770 $327266 $350718 $373664 $397214 $443778 $503666 $352004 $354164 $376232 $401620 $424888 $475430 $539892 $419320 $421480 $444160 $467136 $494940 $553096 6268 6270 6275 6779 6887 6985 500V Dim. Pg. 10 6268 6270 6774 6779 6887 6985 10 6776 6778 6785 6896 6996 6999 10 10 6890 6896 6996 6999 10 PRICES - 700 Volts (3 Phase, 6 Controlled Pulse Power Supply➁) Suitable for constant torque to 5% of base speed 6157 6160 6164 6262 6275 6779 F Rise, 150% O.L. 6168 6268 6270 6275 6779 6881 HP 1500 6268 6270 6275 6779 6881 6887 1750 10 * Basic list price applies to frames listed. Prices include standard papermill features listed on page XX. Refer to Modification section for other accessories and modifications. ➁ For suitability of operation with rectified power supplies, see page xx. ➃ Standard shaft for frames CDL182AT-CD5010AY, CD6000, and CD6100 is suitable for belt drive or direct coupling (within limits given in Application Section Frames CD 6200, CD6700, CD6800, and CD6900 are suitable for direct drive only. 10 Refer to GE for frame. d Top Speed; Class F=900, Class B=600 2.28 HP Base Speed RPM Rated Top Speed RPM 2000 Base Speed RPM Rated Top Speed RPM Basic List Price* GO-2A Frame ➃ 850 650 500 450 400 350 850 650 500 450 850 650 500 1000 900 850 810 770 720 960 900 800 760 900 840 750 $421084 $443962 $467074 $480620 $494164 $535180 $473302 $498796 $524814 $649850 $590782 $628102 $677922 6876 6881 6996 6999 6999 6991 6881 6990 6996 6999 6896 6996 6999 700V B Rise, 200% O.L. Dim. Pg. Basic List Price* GO-2A Frame ➃ $483060 $509370 $535948 $551524 $567102 $614268 $543112 $572428 $602348 $746140 $678214 $721132 $778424 6986 6990 6999 700V Dim. Pg. 10 6999 10 10 6996 6999 10 6896 6996 6999 NOTE: Motors rated 1000HP and above may need external reactance (supplied by customer) included in the circuit to limit ripple current when powered by rectified power supplies (see page XX). GEP387L 09/11 • Prices and data subject to change without notice. 3000 3500 www.gemotors.com • 800-541-7191 TR-15905 TR-15906 GEP387L 09/11 • Prices and data subject to change without notice. 12.5 12.5 2.29 Motor Pricing Modifications Pricing Accessories & Modifications Outline Dimensions Application Information Other If input frequency is 60 hertz and no series inductance is added externally to the motor armature circuit, these Motors are suitable for operation with MG sets or with the quantities need not be indicated and shall be permitted to be rectified power supplies described below: omitted from the identification of the power supply. However, a. Single-phase, full wave, 60 cycle if one of these qualities is indicated, then both shall appear (Power Supply Identification K) Only motors rated 7.5 HP or less, 180 Volts, are suitable for to avoid confusion (NEMA MG1-2009, part 10.61.2). this type of power supply. These ratings do not require an For other types of power supplies, refer to GE. external reactor. For AC supplies other than 230 volts, 60 Standard shunt field voltages are as shown under field voltage cycle, refer to GE. modification. (Refer to the Modifications Section Item XX) b. Three-phase modified, 60 cycle Reactors (Power Supply Identification D) All DC motor ratings in CD6000-CD6900 frames operating This power supply has three controlled rectifiers and three on twelve pulse, three phase rectified power supplies and uncontrolled rectifiers plus a free-wheeling rectifier. It all ratings in CD6000-CD6200 frames operating on less produces the three pulses per cycle. Motors rated 250 HP than twelve pulse rectified power supplies do not require or less in frames CD5010AY and below may be used on external inductance. this type of power supply. No external reactors are DC motor ratings in CD6700-CD6900 frames operating on less required for motors in frames CD5010AY and below, than twelve pulse rectified power supplies may require external although improved operation at low speeds may be inductance to limit the armature circuit current ripple to assure obtained on frames CD365AT-CD5010AY using a reactor. acceptable commutation and long brush, commutator and The 240 volt motors are based on 230 volt, three-phase, bearing life. Armature current ripple is determined by power 60 cycle AC voltage applied to the rectifier bridge, while supply type, ration of DC to AC line voltage, and total circuit the 500 volt motors are based on 460 volt, three-phase, inductance. For DC motors in CD6700-CD6900 frames rated at 60-cycle AC voltage applied to the rectifier bridge. the following horsepower and speed combinations or for any c. Three-phase, full wave 60 cycle rating in CD6700-CD6900 frames having an armature circuit (Power Supply Identification C) inductance of 0.2mH and less, GE recommends a 0.5mH This power supply has six controlled rectifiers and produces external reactor. GE experience indicates that this is especially six pulses per cycle. The 240 volt motors are based on 230 true of applications where the motor is operated at rated load volt, three-phase, 60-cycle AC voltage applied to the rectifier and speed or higher for extended periods. bridge, while the 500 volt motors are based on 460 volt, Horsepower Base Speed (RPM) three-phase, 60-cycle AC voltage applied to the rectifier 1000-1250 850 and above 1500 650 and above bridge. Motors in AC voltage CD6000-CD6900 are suitable 1750-3000 500 and above only for operations from six-controlled, 3 leg power supplies. d. Three-phase, full wave other than 60-cycle, 240 volt DC When external reactance is used, it should be installed in (230 volt AC) or 500 volt DC (460 volt AC) series with the A1 leads of the motor. Power supplies of this type require identification The reactor should be sized to have the following: as follows: Continuous and overload DC rating equal to the motor rating. M/N F-V-H-L where: AC RMS current rating equal to 25% of motor DC rated current M = a digit indicating total pulses per cycle. for large variance between AC supply and rectified DC voltage. N = a digit indicating controlled pulses per cycle. Frequency rating equal to 360 Hz F = free wheeling (this letter appears only if free Enclosure equal to NEMA 1 or as suitable for environment. wheeling is used). Following is one source for the reactors described above: Transformer Engineering Corporation V = three digits indicating nominal line-to-line AC voltage 2550 Brookpark Road, Cleveland, Ohio 44134 to the rectifier. Ph. (216) 741-5282 H = two digits indicating input frequency in hertz DC Current Design %AC RMS Amps of DC Amps L = one, two, or three digits indicating the series induc1000 TR-15902 25 1500 TR-15903 25 tance in millihenries (may be zero) to be added 2000 TR-14711 25 externally to the motor armature circuit. 2500 TR-15904 12.5 Terms Motor Operation from Rectified Power Supplies General Information Power Supplies Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Motor Pricing Notes 2.30 www.gemotors.com • 800-541-7191 GEP387L 09/11 • Prices and data subject to change without notice. Accessories and Modifications . . . . . . . . . . . . . . . . 3.2 3.2 3.2 3.2 3.2 3.3 3.4 3.4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8 3.8 3.9 3.10 3.11 3.11 3.12 3.13 3.15 3.17 3.17 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Overload-Maximum Load . . . . . . . . . Pump Motors . . . . . . . . . . . . . . . . Seals, Drive End Shaft . . . . . . . . . . . Severe Mechanical Duty . . . . . . . . . Shaft Extensions . . . . . . . . . . . . . . Shaft Grounding Brush . . . . . . . . . . Space Heaters. . . . . . . . . . . . . . . . Speed Limit Device . . . . . . . . . . . . . Speed Range Greater than Standard by Field Control . . . . . . . . . Tachometer Generator Equipment . . . Terminal Board in Conduit Box . . . . . . Tests and Curves . . . . . . . . . . . . . . Temperature Detectors . . . . . . . . . . Vertical Mounting . . . . . . . . . . . . . . Voltages . . . . . . . . . . . . . . . . . . . Warranty Extension . . . . . . . . . . . . Windings, Stabilized Shunt, Compound or Series . . . . . . . . . . . . . . . . . . . Mod Shop Pricing . . . . . . . . . . . . . . . . . . . . . . 3.17 3.18 3.18 3.18 3.19 3.20 3.20 3.21 . . . . . . . . 3.22 3.24 3.28 3.29 3.30 3.30 3.31 3.31 . 3.32 . 3.34 Motor Pricing . . . . . . . . Accessories & Modifications . . . . . . . . Accessories & Modifications . . . . . . . . Application Information . . . . . . . . Page Other 10 11 12 13 14 15 16 17 18 19 Accessory Mounting . . . . . . . Air Pressure Switch . . . . . . . . Altitude . . . . . . . . . . . . . . . Ambient Temperature . . . . . . Balance, Mechanical . . . . . . . Bases . . . . . . . . . . . . . . . . Bearings . . . . . . . . . . . . . . Brakes. . . . . . . . . . . . . . . . Canadian Standards Association (CSA) . . . . . . . . . European Standards, CE Marks Conduit Boxes . . . . . . . . . . . Covers. . . . . . . . . . . . . . . . Crane Motors . . . . . . . . . . . Customer-Supplied Material . . Drains . . . . . . . . . . . . . . . . Enclosures . . . . . . . . . . . . . Endshields . . . . . . . . . . . . . Export Boxing . . . . . . . . . . . Grease and Fittings . . . . . . . Item Description Terms 1 2 3 4 5 6 7 8 9 Page Outline Dimensions Item Description General Information CD180AT through CD6900 Index www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.1 Accessories and Modifications ITEM 1 Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 2 DESCRIPTION ACCESSORY MOUNTING The accessory mounting face is standard on all CD180ATCD6900 frames, permitting the ease of adding a variety of accessories, including tachometers and speed limit switches. When accessories are not specified, the accessory mounting face and shaft extension are protected by a solidly attached cover that can be removed easily. (Outlines on pages ___ and ___) On TEFC CD180AT and CD210AT frames and all explosionproof frames, accessory mounting face is not available. Accessory Mounting—Standard motor frames CDL182ATCD5010AY are constructed to allow the addition of tachometers or speed limit switches. AIR PRESSURE SWITCH Differential air pressure switch (1-form-C contact, 10amp, 120V, 60 Hz) Used to indicate positive pressure into the motor from an external source. CAUTION: Switch must be mounted vertical. 3 $2782 $3650 ALTITUDE Motors and generators are suitable for operation at altitudes from sea level to 3,300 feet above sea level. For other conditions, refer to GE or frame sizes. List Price Additions 4 Application Information Outline Dimensions Accessories & Modifications List Price Addition Blower Ventilated/Separately Ventilated Motor Totally Enclosed Air-To-Air Cooled (Internal air circuit only) Terms Other 5 3.2 Altitude Frames CD5010AY Frames CD6000 and Above 3,301-8,800 Ft. 8,801-15,000 Ft. Add 15% Add 22% Add 10% Add 15% AMBIENT TEMPERATURE Standard motor is suitable for operation in an ambient temperature of 0°C to 40°C. For ambient temperature greater than 40°C, see List Price adder at right: Refer to GE for frame size. Refer to GE for applications in an ambient temperature higher than 65°C or lower than 0°C. List Price Additions Ambient 500 HP and Less 600 HP and above 41°C-60°C 61°C-65°C Add 20% Add 25% Add 10% Contact GE BALANCE, MECHANICAL Vibration measurements are made on motor bearing housings as described in NEMA Standard 1.12.06. Amplitude is expressed as inches peak-to-peak. Vibration limits for standard and precision balance are for the motor only without any mounted accessory. The same limits can generally be met with motor-mounted blowers, PY, and AN tachometers. Motors with a BC tachometer or a motor-mounted brake will have peak-to-peak amplitudes of 2 times the value shown below. Where vertical mounting is required, it should be specified on the order. (For special run out, refer to GE.) NEMA Standard Vibration Limits Maximum NP Rated RPM Peak-to-Peak Amplitude (inches) 3000-4000 1500-2999 1000-1499 0-999 0.0010 0.0015 0.0020 0.0025 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications DESCRIPTION Precision balance limits at top speed 0.0002 CD320AT-CD360AT CD407AT-CD5010AY PEAK-TO-PEAK AMPLITUDE (INCHES) 0.0003 0.0004 MOTORS LIST PRICE Description Up to $2500 $2501 to $3592 $3593 to $5578 $5579 to $9748 $9749 to $13219 to $23923 to $42137 to $61751 to $13218 $23922 $42136 $61750 $98628 $98629 and up List Price Addition Precision Balance Not Available $1338 $1582 $2094 $2688 $3210 $4564 $5490 Not Available BASES For P-Base see Endshields, Page 3.15. 6a Standard Sliding Base Sliding bases are suggested as a convenient means for adjusting belt tension or may be used as mounting plates. (For horizontal mounting only — not available for ceiling or sidewall mounting.) (Not available on CD6700 through CD6900 frames) 6b Transition Base Transition bases may be used to match the mounting dimensions of another motor which has a larger “D” dimension. (A drawing must be provided at the time of order.) This option is available if, and only if, the shaft height of the older motor is reasonably higher (varies with motor size, but typically greater than 1 inch is sufficient) than the shaft height of the Kinamatic™ motor at the same rating. For horizontal floor mounting only. Refer to Replacement Motors/Mechanically interchangeable section on page 10 for additional details. A special shaft extension may be required. 6c Sole Plate Sole plates are two (2) flat steel plates to be mounted in concrete by the customer to provide a mounting surface for the motor. Refer to pages ___-___ for outlines. Outline Dimensions Accessories & Modifications 6 Accessories & Modifications CD210AT-CD280AT MOTOR LIST PRICE Description Up to $2500 $2501 to $3592 $3593 to $5578 $5579 $9749 $13219 $23923 $42137 $61751 $98629 $157704 $252289 $403651 to to to to to to to to to and $9748 $13218 $23922 $42136 $61750 $98628 $157704 $252288 $403650 up a. Standard Sliding Base $316 $316 $316 $540 $630 $1216 $1600 $2160 $2860 $3844 $6154 b. Transition Base $700 $810 $944 $1260 $1700 $2300 $3100 $4160 $5560 $7440 $10022 $13724 $18070 c. Sole Plate $630 $630 $630 $870 $1110 $1530 $2090 $2760 $3750 $5026 $6760 $9150 $12300 Application Information Frame Size Motor Pricing 5 Improved balance vibration limits (applies to listed ratings only). For other speed ranges, refer to GE. Precision Cont’d balance is not available on CD180AT, CD6000-CD6900 frames, nor explosionproof motors. Contact GE Terms Other ITEM General Information CD180AT through CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.3 Accessories and Modifications ITEM DESCRIPTION 7 BEARINGS (Belted Drive) Standard shaft for frames CD180AT-CD6100 are suitable for either belt drive or direct coupling within the limits given in the application section on page XX (was page 179). Frames CD6200-CD6900 are suitable for direct drive only. Where the maximum radial load at the end of the shaft exceeds the standard limits, oversize ball bearings and roller bearings are available as listed below. Maximum radial loads and speeds for these modifications are given on pages ____ Motor Pricing General Information CD180AT through CD6900 STANDARD SIZE ROLLER BEARING ON DE CD287AT, CD288AT Add $1044 OVERSIZE ROLLER BEARING ON DE* CD218-CD2110 Add $366 CD287AT, CD288AT Add $1210 CD258-CD288 $468 CD327AT, CD328AT, CD329AT $1044 CD327AT, CD328AT, CD329AT $1210 CD327-CD328 $574 CD365AT-CD508AT $1732 CD365AT-CD5010AY $2498 CD365-CDL407 $680 CD6000 (Top spd. 1750 RPM) $3334 CD409-CDL409 $766 CD6100 (Top spd. 1500RPM) $3860 CD504-CDL508 $892 Not Available on frames CD180AT, CD210AT, CD258AT, CD259AT, CD5010AY, CD6200, CD6700, CD6800, CD6900 Not available on frames CD180AT, CD210AT, CD258AT, CD259AT, CD6000-CD6900 * When an oversize bearing on DE is specified, a standard DE shaft extension will be furnished. However, if also required an oversize DE shaft is available at no additional price. 8 BRAKES — Refer to GE for application of brakes rated above 100% of rated motor torque. Order must specify AC/DC voltage and frequency, torque rating (Lb. Ft.), enclosure, and orientation with respect to the motor. Customer is responsible for specifying brake torque rating. GE does not recommend the use of brakes on TEFC Kinamatic motors. When brakes are required, GE recommends TEAO enclosures. 8a BRAKES, DISC TYPE These brakes are applicable for holding service within rating limitations shown in the table on the next page. Where brakes are required for stopping duty, the heat-dissipating capacity may be the Disc type brakes — Disc type brakes are commonly determining factor in the brake selection. In such cases, refer to GE. used on ratings 250 HP and below. The brakes are continuously rated and can be mounted on CD180ATBrakes are continuously rated and are nonadjustable spring set and CD5010AY frames. electrically released. For brakes of a specific manufacturer, nonlisted capacity, or adjustable or electrically set brakes, refer to GE. For frames CD6000-CD6900, use floor-mounted brakes. AC brakes are recommended on disc brake applications wherever possible, especially for those applications where high cycling duty may occur (e.g., on hoist or screw-down applications). Use a brake of standard enclosure with dripproof fully guarded or splashproof fully guarded motors, and on TENV and TEAO motors for applications in ambients containing chips and/or non-abrasive, non-conducting, and non-explosive dusts and coolants. Terms Other Application Information Outline Dimensions Accessories & Modifications Accessories & Modifications OVERSIZE BALL BEARING ON DE* 3.4 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications Motor Pricing Standard brake features include: • Class B Insulation • Standard AC brake coils are rated as follows: • Spring Set, electrically released Nominal Suitable Range 460 440-480 • Manual release with automatic reset 60Hz 230 220-240 • Standard or dust tight waterproof enclosure 380 360-400 50Hz • CSA certification 190 180-200 • 115 or 230 Volt DC coils • Horizontal mounting Note: Single voltage coils are supplied on brakes rated 750 lb. ft. and above. Voltage must be specified at time of order. WARNING: Brake performance and features must be carefully matched to the requirements of the application. Consideration must be given to torque requirements, especially where an overhauling condition exists, as well as thermal capacity, ambient temperature, atmospheric explosion hazards, type of enclosure, power supply characteristics, and other unusual conditions. Improper selection or installation of a brake and/or lack of maintenance may cause brake failure, which can result in damage to property and/or injury to personnel. If injury to personnel could be caused by brake failure, proper safeguards must be provided to ensure safety of personnel. Motor Torque (Lb. Ft.) = $1184 $1248 $1248 $1248 $1316 $1417 $1619 $2024 $2833 $3778 $8703 $9040 $9715 $10524 $11738 $18889 $20913 $22937 $1882 $1980 $2058 $2058 $2125 $2226 $2429 $2833 $3643 $4587 $10052 $10389 $11064 $11873 $13088 $20913 $22937 $24961 $1815 $1903 $2017 $2017 $2085 $2186 $2388 $2793 $3602 $4547 $10814 $11151 $11826 $12636 $13850 $22431 $24455 $26479 $2554 $2808 $2827 $2827 $2894 $2995 $3198 $3602 $4412 $5356 $12163 $12501 $13175 $13985 $15199 $24455 $26479 $28503 Application Information 3600 3600 4000 4000 4000 4000 4000 4000 4000 4000 3600 3600 3600 3600 3600 1800 1800 1800 Other 1.5 3 6 10 15 25 35 50 75 105 125 175 230 330 440 500 750 1000 Motor Mounted Brake AC Coil DC Coil Standard Enclosure Dust Tight/Waterproof Standard Enclosure Dust Tight/Waterproof NEMA 2 NEMA 4 NEMA 2 NEMA 4 IP23 IP54 IP23 IP54 Terms Lb. Ft. Maximum Horizontal Speed (RPM) HP x 5252 Motor base speed (RPM) Customer is responsible for specifying brake torque rating. www.gemotors.com • 800-541-7191 Accessories & Modifications 8a Cont’d Accessories & Modifications DESCRIPTION Outline Dimensions ITEM General Information CD180AT through CD6900 GEP387M 09/11 • Prices and data subject to change without notice. 3.5 Accessories and Modifications ITEM DESCRIPTION 8a OPTIONS: (Prices below in addition to brake price on previous page) Cont’d BRAKES WITH ACCESSORY MOUNTING When mounting a second accessory (such as a 56 C-face tachometer or a speed limit device) on DPFG, TENV, TEAO, TEAAC or TEWAC motors, a brake with accessory mounting is required. Add as follows: (Exceptions are noted below) Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 Brake Torque Lb. Ft. List Price Addition 10-105 125-440 500-1000 $3976 $4446 $4800 Accessories & Modifications Note: Only “AN” style tachometers or a speed limit switch can be mounted with a brake on CD180AT frames. Brake with accessory mounting is not required because the brake is mounted on the tach or speed switch. Note: When mounting a brake (up to and including 330 lb. ft.) with a Northstar or Avtron Type AN-DG tach a standard brake can be used. The brake is mounted on the tach. Note: AN-DG tachs will not be mounted outboard a brake. Application Information Outline Dimensions VERTICAL MOUNTING For a brake mounted above the motor on DPFG or TENV motors, add as follows: List Price Addition 1.5-6 10-105 125-1000 $458 $640 $1132 BRAKE SPACE HEATER BRAKE RELEASE INTERLOCK SWITCH A brake space heater should be specified whenever a heater is required on the motor. For brake space heater, add as follows: Add as follows: Brake Torque Lb. Ft. List Price Addition Brake Torque Lb. Ft. List Price Addition 1.5-105 125-1000 $320 $480 1.5-105 125-440 500-1000 $708 $842 $1560 EXPLOSIONPROOF BRAKES Refer to GE Terms Other 8b Brake Torque Lb. Ft. 3.6 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications ITEM DESCRIPTION Motor Pricing DISC BRAKES — CRANE APPLICATIONS Brakes used on the gantry or trolley function on dockside, portal, or queue cranes require special brakes. Order must specify crane duty and whether trolley or gantry. The features listed below are included on crane duty brakes. Accessories & Modifications Accessories & Modifications Standard Crane Duty Brake Features include: • Splined hubs (Zinc plated) and discs • Stainless steel self-adjusting assembly • Full mechanical release with side mounted release lever. Note: Release is not self-resetting • Stainless steel hardware • Space heaters • Brake interlock switch • Dust tight, waterproof enclosure • 56" lead lengths When specifying vertical or horizontal, add as follows: Motor Mounted Brake AC Coil Dust Tight/Waterproof Lb. Ft. 50 75 105 125 175 230 330 440 $5751 $6561 $7545 $13538 $13875 $14651 $15460* $16945* Horizontal Trolley Gantry $5238 $6048 $6992 $12762 $13099 $13774 $14583* $15798* $5238 $6048 $6992 $17022* $17359* $18034* $18843* $20058* Application Information Vertical Outline Dimensions List Price Addition Viton Gasket: Proximity Switch: Breather Drain: Terminal Board: Other * Includes fabricated commutator endshield. Lb. Ft. Torque = HP x 5252 Motor base speed (RPM) To replace standard neoprene gasket. To replace standard brake interlock switch (microswitch). To replace standard drain plug. To replace 56" lead lengths. List Price Addition Brake Rating Viton Gasket Proximity Switch Breather Drain Terminal Board 105 Ft. Lb. and Smaller 125 Ft. Lb. and Larger $138 $220 $1855 $3767 $552 $614 $180 $180 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Terms 8c General Information CD180AT through CD6900 3.7 Accessories and Modifications ITEM 9 DESCRIPTION CANADIAN STANDARDS ASSOCIATION (CSA) APPROVAL For CSA approval, no price addition except for TEAAC, TEWAC enclosures in a CD5010AY frame, add $500 NET. For explosionproof motors adder, refer to page 2.24. Note: CSA approval must be specified at time of order. 10 Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 CE MARK, EUROPEAN STANDARDS This modification provides for a motor that meets the standards requirements of the Low Voltage Directive 73/23/ EEC and relevant sections of the Machinery Directive 98/37/EC and EMC Directive 89/336/EEC. These motors will be CE marked on the nameplate in accordance with the marking requirements of the Low Voltage Directive. FRAME SIZE CD210ATCD320AT Motor Enclosure CD360AT CD400ATCD500AT CD6000-CD6200 CD6700-CD6900 $3200 $5310 $6400 $3700 $5310 $9530 List Price Addition Accessories & Modifications SPFG*, SPFG-SV*, TENV, TEFC SPFG-BV*, TEWAC, TEAO TEAAC $2000 $3154 • $2100 $3254 • $4408 $2900 $4054 • $5208 * The price addition for CE mark does not include the splashproof enclosure modification. See splashproof enclosure price additions on page __. • TEWAC not available on CD210AT-CD400AT frame motors. Application Information Outline Dimensions CE mark pricing includes: • Terminal board in conduit box • Ground lug in conduit box • Ground lug and tapped holes in foot (only on motors rated 100kw and higher) • Special nameplates • 50 Hz marked blower motor(s) on blower ventilated, TEAO, TEAAC, TEWAC • Declaration of Conformity, Declaration of Incorporation • Instruction book in either Spanish, French, German, Italian or English Terms Other Note: All CE marked motors must be reviewed with Engineering to make sure CE temperature rise limits are met. If the standard motor does not meet CE mark temperature rise limits (on armature and comm field), the price addition for Class B temperature rise must be used in addition to the above CE mark price additions. Note: CD180AT and Explosionproof ratings are not available for CE marking. Note: DPFG, DPFG-BV, and DPFG-SV motor enclosures are not available for CE marking. Note: CE approved accessories must be used. 3.8 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications 11 CONDUIT BOXES, SPECIAL Note: F1 - The conduit box is located on the right-hand side (as viewed from the commutator end). F2 - The conduit box is located on the left-hand side (as viewed from the commutator end). On CD180AT frames, other than explosionproof, the conduit box is built into the endshield and is available in the F1 location only. On all other frames, a standard conduit box is used. CD6000-CD6900 frames, as standard, provide a conduit box with fixed terminations for armature, field, and internal accessory leads. Special conduit boxes are as follows: 11a AUXILIARY CONDUIT BOX OR CONDULET Allows accessory leads to be brought into a separate conduit box of condulet. When this feature is specified, the auxiliary conduit box or condulet will always be supplied on the side of the motor which is opposite to the main conduit box location. Note: The purchaser must specify which accessory leads are to be brought to the auxiliary conduit box or condulet. Accessories external to the motor are not wired to the auxiliary box or condulet. The addition of this modification does not provide a U.L. listed explosionproof motor. A thermostat is required when an explosionproof conduit box is supplied with a separately ventilated motor. Accessories such as tachometers or brakes mounted on the motor must be of the explosionproof type. See page 24, Item 28 for BC tachs. Refer to GE for explosionproof brakes. 11d OVERSIZE CONDUIT BOX Supplied at no additional price on frames CD218AT-CD5010AY upon request. Price addition is required for oversize conduit box on frames CD6000-CD6900. Terms Other 11e TOP MOUNTED CONDUIT BOX On frames CD218AT-CD5010AY, top mounted conduit boxes are not available with a TEAAC or TEWAC enclosure. Refer to GE for top mounted conduit boxes on blower ventilated CD218AT-CD5010AY frames. Top mounted explosionproof box not available on CD210AT-CD320AT. Application Information 11c EXPLOSIONPROOF CONDUIT BOX AND SEALED LEADS ON SEPARATELY VENTILATED MOTORS (Not available on frames CD180AT) For use only on enclosed separately ventilated motors with air ducted-in and air ducted-out ventilation. Section 501-8 and 502-8 of the National Electrical Code permits the use of enclosed separately ventilated motors with air ducted-in and air ducted-out ventilation in certain locations, when installation and operation conform to certain requirements. It is the responsibility of the user to obtain approval from the local authorities for such installation. For additional information, see page __. Outline Dimensions Accessories & Modifications 11b CAST IRON CONDUIT BOX Not available on all frames. Motor Pricing DESCRIPTION Accessories & Modifications ITEM General Information CD180AT through CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.9 Accessories and Modifications ITEM DESCRIPTION 11f WATERPROOF CONDUIT BOX For use on splashproof or better enclosure. For use where motors are required to exclude water applied from a hose and for outdoor application. Included in the price addition for waterproof motor enclosure. Not available on frames CD6000-CD6900. The standard conduit box used on frames CD6000-CD6900 is gasketed and “water-resistant.” Motor Pricing General Information CD180AT through CD6900 MOTOR FRAME SIZE CD210ATCD320AT SPECIAL CONDUIT BOX CD360ATCD400AT CD504ATCD508AT CD5010AY CD6000CD6200 CD6700CD6900 $4780 $754 $376 $225 $1508 $754 Refer to GE $1508 $754 Refer to GE $1508 $754 Refer to GE $3954 $2116 $6658 $8256 $12044 $51784 $51784 $1875 $1238 $1238 $1806 $7766 $7766 0 $838* $450 0 $2106* $900 0 $2106* $900 0 $2106* $900 $1730 $1730 $4606* $9414* Not Available Not Available * Not available in all enclosures. Refer to Item 11e. 12 Outline Dimensions Accessories & Modifications Accessories & Modifications List Price Addition a. Auxiliary conduit box or condulet: Conduit box for accessory leads Condulet for accessory leads b. Cast iron conduit box c. Explosionproof conduit box with motor leads sealed at the frame exit Standard conduit box with motor leads sealed a the frame exit d. Oversize conduit box e. Top mounted conduit box f. Waterproof conduit box COVER, TRANSPARENT A single transparent cover is used in place of the metal cover on a brush opening at the commutator end. On frames CD218AT-CD5010AY, the standard transparent cover is Lucite® or equivalent. On frames CD6000-CD6900, the standard transparent cover is Lexan® or equivalent. Lexan® is available on frames CD218AT-CD5010AY. See below for pricing per motor. MOTOR LIST PRICE Application Information DESCRIPTION Up to $2500 $2501 to $3593 to $5579 to $9749 to 3592 $5578 $9748 $13218 $13219 to $23922 $23923 to $42136 $42137 to $61750 $61751 $98629 $157704 $252289 $403651 to to to to and up $98628 $157704 $252288 $403650 List Price Addition a. Lucite® or equivalent b. Lexan® or equivalent (Not available on all CD180AT frames or CD210AT TEFC frames.) $270 $270 $406 $406 $406 $406 $540 $540 $540 $812 $812 $812 $812 $1080 Not Available $1080 $1080 Terms Other Lucite® is a registered trademark of DuPont Company. Lexan® is a registered trademark of General Electric Company. 3.10 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. $1080 $1352 Accessories and Modifications 13 CRANE MOTORS GE builds DC motors designed specifically for dockside and floating crane applications. Motors in these applications are main hoists, boom hoists, trolleys, and gantries. Note: CD180AT frames or AN-DC tachs are not used in crane motor applications. Similarly, TEFC enclosures are not suitable for crane applications (use TEAO), TEAAC and TEWAC waterproof enclosures are not available. CD210ATCD250AT CRANE MOTORS a. Indoor main hoist/boom hoist b. Outdoor trolley/gantry c. D-flange $3806 $964 CD280AT Not Applicable $4492 $1054 MOTOR FRAME SIZE CD360ATCD320AT CD400AT List Price Addition $4492 $3466** $2592 $5208 $5322** CD504ATCD5010AY CD6000CD6200 $2592 $5792 $6824** $6382 Not Available Indoor main hoist/boom hoist features include: Outdoor trolley/gantry features include: • Crane duty paint • Space heater • Normally closed thermostat • Special conduit box adapter • Waterproof features • Crane duty paint • Space heater • Normally closed thermostat Accessories & Modifications ** Price includes special bracket. Motor Pricing DESCRIPTION Accessories & Modifications ITEM General Information CD180AT through CD6900 Outline Dimensions • Special conduit box adapter Terms Other Application Information Note: For crane duty brakes, see page 3.7, Item 8c. For voltages other than those listed above, refer to page 3.32 Item 34. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.11 Accessories and Modifications ITEM 14 Terms Other Application Information Outline Dimensions Accessories & Modifications Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 DESCRIPTION CUSTOMER-SUPPLIED MATERIAL No testing is performed and no warranty is provided for customer-supplied material. All customer-supplied material must be sent to the following. Frame Size CD180AT-CD5010AY Monterrey L&M/GE Industrial Motors 605 NAFTA Blvd Milo Distribution Center Laredo, Texas 78045 Attn: Customer Service CD6000-CD6900 14a BRAKE WHEEL Customer-supplied DS brake wheels must be completely machined and dynamically balanced prior to receipt at the factory. The factory cannot rebalance the motor after assembly of customer-supplied brake wheel. Add $3192 list per motor. This price addition is for mounting a brake wheel on the commutator end shaft extension only. Contact GE for mounting any other brake components or assemblies to the motor. Note: Refer to GE for application of brakes rated above 100% of rated motor torque. Mounting/installation instructions, outline dimensions, and parts list must be received at the time of order. Brake wheel must be received at the factory a minimum of 3 weeks prior to customer promise ship date. Brake wheel mounting on frames CD182AT-CD5010AY requires a commutator end shaft extension adder. Refer to page 3.19, Item 24. No adder required for Comm End Shaft Extension on CD6000-CD6900 frames. 14b COUPLINGS (Customer to supply installation instructions for coupling to GE) For mounting a coupling (which must be completely machined and balanced prior to receipt at the factory), WITH finish bore and keyseat, add $3192 list per motor. The factory cannot rebalance the motor after assembly of customer-supplied coupling. Finish bored and key seated coupling and outline drawings must be received at the factory a minimum of 3 weeks prior to customer promise ship date. For mounting a coupling (which must be balanced prior to receipt at the factory), WITHOUT finish bore and keyseat, add $6932 list per motor. Unfinished coupling and outline drawings must be received at the factory a minimum of 4 weeks prior to customer ship date. 14c TACHOMETER GENERATOR EQUIPMENT Customer-supplied tachometers will not be tested. Drawings, installation instructions and parts list of customersupplied tachometers must be received at the factory a minimum of 3 weeks prior to customer ship date. For pricing, refer to page 3.24, Item 29. 14d PAINT Due to hazardous waste disposal regulations and VOC emissions requirements, GE will not accept orders using customer-supplied paint. For special paint requirements needed to meet application and commercial needs, contact GE. 15 DRAINS Drain holes are normally selected to provide drainage of moisture that might collect at the lowest point of the motor. Not available on CD180AT Frames. When drain holes are required, placement for horizontal and vertical mount are as follows: Horizontal Mount (1) at each end, vertical CD210AT-CD320AT: (3) at lowest point, CD360AT and above: (1) at lowest point. 15a TAPPED HOLE, add $430 list per motor. No adder required for Waterproof enclosures. (STD 1 at each end) 15b TAPPED HOLE WITH SOLID PLUG, add $430 list per motor. No adder required for Waterproof enclosures. 15c AUTOMATIC DRAIN BREATHER, add $510 list per motor. Available on totally enclosed CD210AT-CD5010AY frames only. Not available on CD6000 frames. 3.12 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications Accessories & Modifications Accessories & Modifications Dripproof Fully Guarded Blower Ventilated (DPFG-BV) (Shown above with filter) Terms 16b SEPARATELY VENTILATED, FULLY GUARDED OR TOTALLY ENCLOSED SEPARATELY VENTILATED (DPFG-SV) OR (TESV) For applications where a contaminated atmosphere is encountered, ventilating air is piped into the motor or generator from an external source to the commutator end on frames CDL182AT-CD5010AY and to the drive end on CD6000CD6900 frames. Openings have drilled and tapped holes for convenient duct connection. Price does not include blower, pipe or duct. See page ___ for separate ventilating air requirements. Dripproof Fully Guarded, Separately-Ventilated (DPFG-SV) Separately ventilated motors with recommended air supply are (Frame CD366AT shown above with air inlet on top of motor suitable for constant torque operation with allowable operating commutator end. Other air inlet locations available.) temperatures down to five percent base speed with most power supplies. See application section page XX (was page 177) for motor heating limitations. On separately ventilated, fully guarded motors, air is expelled into the surrounding environment through air exhaust openings which are fully guarded. For use of splashproof on separately ventilated, fully guarded motors, see page 3.14, Item 16c. On totally enclosed separately ventilated motors, the ventilating air is ducted in and out of the motor and solid covers are placed on all other air openings. The motor is then inherently splashproof, and the addition of the splashproof modification to a totally enclosed separately ventilated motor is not necessary. Note: CD180AT motors must have an 8 1/2" C-Face. Totally enclosed separately ventilated CD180AT frames in hazardous locations are not available. Outline Dimensions 16a BLOWER VENTILATED, FULLY GUARDED (DPFG-BV) For use on fully guarded motors where the application requires extended periods of low-speed operation by armature voltage control at full load torque. The amount of ventilating air is independent of motor speed, allowing constant torque operation with safe operating temperatures down to five percent rated speed with most power supplies. See application section page XX (was page 177) for motor heating limitations. The standard blower motor is 230/460 Volt AC, 60 hertz and is suitable for (but not nameplated for) 220-240/440-480 Volt AC, 60 hertz. Refer to GE for 50 hertz blowers and special blower motor voltages. Filters are optional for applications requiring protection against particles in the air. For fine particles such as cast iron dust, a blower and filter is not recommended. For these conditions, totally enclosed construction or separate ventilation should be considered. Blower filters on frames CD5010AY and below are washable. Filters for frames CD6000-CD6900 are disposable. For use of splashproof fully guarded on blower ventilated motors, see page 3.14, Item 16d. Motor Pricing ENCLOSURES Application Information 16 DESCRIPTION Other ITEM General Information CD180AT through CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.13 Accessories and Modifications Other Application Information Outline Dimensions Accessories & Modifications Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 ITEM DESCRIPTION 16c SPLASHPROOF FULLY GUARDED (SPFG) (FOR SEPARATELY VENTILATED OR SELF-VENTILATED FULLY GUARDED MOTORS) Provides for bolted-on splash covers to meet NEMA Standard MG-1-2009, Part 1.25.2. The covers are constructed to prevent liquids and solid particles from entering in a straight line at any angle not greater than 60° from the vertical. This does not apply to motors operated in a vertical position. For these applications, refer to GE. For CD180AT frames, splashproof fully guarded, separately ventilated is only available when horizontally mounted. 16d SPLASHPROOF FULLY GUARDED (FOR BLOWER VENTILATED, FULLY GUARDED MOTORS) For splashproof fully guarded, blower ventilated, list price additions for Modifications a. and d. must both be added. Provides for bolted-on splash covers to meet NEMA Standard MG-1-2009, Part 1.25.2. The covers are constructed to prevent liquids and solid particles from entering in a straight line at any angle not greater than 60° from the vertical. In addition, on CD6000-CD6900 frames with a splashproof fully guarded, blower ventilated enclosures, splashproof hoods are required to cover the blower air inlets. See page ___ for outline dimensions of frames CD6000-CD6900 with a splashproof, fully guarded blower ventilated enclosure. This does not apply to motors operated in a vertical position. For these applications, refer to GE. For CD180AT frames, splashproof fully guarded, blower ventilated is only available when horizontally mounted. 16e WATERPROOF (WP) For use where motors are required to exclude water applied from a hose and for outdoor application. (Do not use where ice may form on fan of TEFC motors or generators.) Waterproof features are not available in TEAAC or TEWAC. Standard waterproof features for frames CDL182AT-CD5010AY (TEFC, TENV, and TEAO) include: • Spot faced surfaces on frame under the pole bolts • Washers under pole bolts • Drain holes at low point of machine • Polyurethane paint • Special neoprene-gasketed, heavy handhold covers with machined surfaces on cover and bearing bracket • Waterproof conduit box with tapped conduit entrance hole and machined mating surfaces (Not on CD180AT. On CD180AT frames the conduit box is built into the endshield.) Totally Enclosed Nonventilated Waterproof (TENV-WP) • Sealed frame fits and special treatment of all mating (Frame CD407ATY shown above) surfaces • Lip type rubbing seals on both outboard bearings (where applicable) • Corrosion-resistant hardware Terms Space heaters are recommended for all waterproof motors. 3.14 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications MOTOR LIST PRICE Up to $2500 $2501 to $3593 to $5579 to $9749 to $3592 $5578 $9748 $13218 $13219 to $23922 $23923 to $42136 $42137 to $61750 $61751 to $98628 $98629 $157704 $252289 $403651 to to to and up $157704 $252288 $403650 List Price Addition a. Blower Ventilated Motor-mounted blower with filter: 230/460 V or 575V, 3Ph, 60 Hz Motor-mounted blower without filter: 230/460V or 575V, 3Ph, 60 Hz For 190/380V, 50 Hz Blower Motors, add to blower assembly (a) above b. Separately ventilated, fully guarded or enclosed separately ventilated c. Splashproof, fully guarded (for use with self of separately ventilated, fully guarded machines) d. Splashproof, fully guarded (for use with blower ventilated fully guarded machines) Modification Item a. must also be added for splashproof, fully guarded, blower ventilated e. Waterproof f. Dustproof (taconite dusts) $1472 $1472 $1472 $2274 $2576 $2866 $3158 $3706 $4778 $13578 $16848 $28904 $28904 $1032 $1032 $1032 $1814 $1814 $2318 $2318 $3014 $4306 $7090 $8214 $12516 $12516 $208 $208 $208 $364 $364 $464 $464 $604 $862 $1418 $1644 $2504 $2504 For CDL182AT-CD5010AY and CD6000-CD6900 frames, NO PRICE ADDITION $204 $204 $420 $636 $810 $810 $810 $810 $1216 $1216 $1216 $1216 $1620 $204 $312 $420 $636 $810 $810 $810 $810 $1216 $4086 $4086 $6762 $7368 $1502 $304 $1502 $340 $1658 $486 $2050 $756 $2520 $988 $3100 $620 $3810 $1570 $4710 $1700 $5780 $1970 Not Available Not Available Terms Note: Items e. and f. apply to totally enclosed motors. Items b. and c. apply to splashproof fully guarded, separately ventilated motors. Items a. and d. apply to splashproof fully guarded, blower ventilated motors. Application Information ENCLOSURE Accessories & Modifications 16g TROPICAL PROTECTION The standard Kinamatic motor is suitable for operation in tropical climates, where fungus and high humidity are present, without price addition. Space heaters are recommended for motors to be used in environments where high humidity is present. (See page 3.20, Item 26 for space heaters.) Accessories & Modifications Motor Pricing DUSTPROOF (DP) Applies to frames CDL182AT-CD5010AY with TEFC and TENV enclosures only. For applications requiring protection against fine abrasive dust such as taconite. Price addition includes: • Metal labyrinth seal on drive end • Gasketed handhole covers • A sealed dust cap on the commutator end of TENV motors • A labyrinth seal on the commutator end of TEFC motors. For cement mill applications or for TEAAC or TEWAC motors, refer to GE. Other 16f DESCRIPTION Outline Dimensions ITEM General Information CD180AT through CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.15 Accessories and Modifications ITEM 17 DESCRIPTION ENDSHIELDS Standard NEMA Type C-Face and Type D-Flange dimensions are shown on the dimensions pages. Refer to GE for CD6000-CD6900 frames. Where oil will be above the bottom of the horizontal shaft, including splashing or spraying, a special shaft seal is required. (Refer to page 3.18, Item 22 for shaft seal.) 17a Type C-Face Endshields are available on frames CD320AT and below. NEMA does not specify C-Face dimensions for CD365AT-CD5010AY frames. The desired C-Face dimensions must be approved by GE and specified with the order. 17b Type D-Flange Endshields are available on frames CD5010AY and below. Available on frame 5010AY if supported by feet. NEMA Type C-Face Endshield 17c P-Base Adapters — NEMA does not specify P-Base dimensions for DC motors. The desired P-Base dimensions must be approved by GE and specified with the order. The factory will use an adapter on a D-Flange (price included in P-Base adder) to achieve desired dimensions. Apply adder from page 3.31, Item 33 for vertical mounting. If special drive end shaft dimensions are required, see page 3.19, Item 24 for adder. MOTOR FRAME SIZE SPECIAL ENDSHIELDS CD180AT CD210AT CD250AT CD280AT CD320AT CD360AT CD400AT CD500AT CD5010AY List Price Addition a. Type C-Face b. Type D-Flange c. P-Base Adapter Outline Dimensions Accessories & Modifications Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 $172† $216 $648 $502 $964 $1928 $652 $1060 $2312 $846 $1706 $2774 $1100 $1282 $3328 ‡ ‡ ‡ ‡ $5356 $6652 $6644 $8636 $7308‡‡ $9500 $7308‡‡ $9500 †For CD180AT frames, please specify 4.5" or 8.5" C-Face. ‡Contact GE ‡‡On CD5010AY frames, motor must also be supported by feet. Application Information The following chart details the standard endshield material used on Kinamatic motors. Non-standard Kinamatic motors manufactured for special applications may not use standard endshield material. Refer to GE for nonstandard motors. MOTOR FRAME SIZE ENDSHIELD CD180AT CD210AT CD250AT CD280AT CD320AT CD360AT CD400AT CD500AT CD5010AY Other STANDARD ENDSHIELD MATERIAL a. Standard Drive End Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron b. C-Face Drive End Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron c. D-Flange Drive End Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron d. P-Base Drive End Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Fabricated Steel Fabricated Steel Fabricated Steel e. Commutator End Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Not Available Not Available Not Available Fabricated Steel Fabricated Steel Fabricated Steel Fabricated Steel Fabricated Steel Fabricated Steel Cast Iron Cast Iron Cast Iron Terms Price addition for fabricated steel (per endshield) is as follows: 3.16 Motor Frame Size List Price Addition CD210AT-CD320AT CD360AT CD400AT CD5010AY $2412 $3600 $4268 $4826 www.gemotors.com • 800-541-7191 Ductile Iron Fabricated steel is available. GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications 19 CD250CD320 CD365CD409 CD504CD5010 CD6000CD6100 CD6200 CD6700 CD6800 CD6900 Net Price $400 $600 $800 $1000 $1400 $2000 $2500 $3000 $3700 GREASE AND FITTINGS 19a GREASE The following greases are available: Standard (Alvania® #2) or equivalent. Suitable for 15°F (-10°C) to 212°F (100°C) ambient temperature. No price addition. Low Temperature (Shell Aeroshell® #7) or equivalent. Suitable for -60°F (-51°C) to 200°F (93°C) ambient temperature. Add $172 list per motor. High Temperature (Mobil Polyrex EM®) or equivalent. Suitable for -20°F (-28°C) to 350°F (176°C) ambient temperature. Add $172 list per motor. 19b FITTINGS Grease fittings — Not necessary on frames CDL182AT-CD2110AT because prelubricated and shielded bearings are standard. On CD258AT-CD5010AY and CD6000-CD6900 frames, zerk grease fittings are standard. When grease fittings are required, open ball bearings and bearing caps are included. (Not available on CD180 frames.) No price addition. For re-greaseable bearings with standard alemite grease fittings on CD218AT-CD2110AT, add $516 list per motor. For special grease fittings, button head, pin head or other than standard, add $172 list per motor. Pressure Relief Valve add $172 list per motor. Percent Base Speed Occasionally Repeated Loads Frequently Repeated Loads 100% 200% 300% or greater 150% 150% 140% 140% 130% 125% Application Information CURRENT OVERLOAD — MAXIMUM LOAD AT BASE SPEED In accordance with NEMA standards, continuous rated industrial DC motors rated 3/4 HP/RPM and less shall be capable of occasionally repeated loads of 150% of the base speed full load current at all speeds within the standard speed ranges listed on pages __-__. Although NEMA does not specify frequently repeated load capability, DC motors in these ratings are capable of 140%. For motors larger than 3/4 HP/RPM, the following load capability applies: Other 20 For occasionally repeated load capability of 200% with a frequency repeated load capability of 175% on motors rated 3/4 HP/RPM and less with standard speed ranges listed on pages __-__ and on motors rated larger than 3/4 HP/RPM at base speed only, add 10% and refer to GE for effect on frame size. Occasionally repeated loads are defined as one-minute duration or less and are not considered as part of the regular duty cycle. Occasionally repeated loads are considered as commutation limits rather than heating limits. Frequently repeated loads are defined as one-minute duration or less repeated such that the RMS current does not exceed rated current over any five-minute period. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Motor Pricing CD182CD2110 Accessories & Modifications FRAME SIZE Export Boxing Accessories & Modifications EXPORT BOXING The price for export boxing is a NET PRICE adder applied to the total price of the motor after adjusting for all modifications. Export boxing must be specified at the time of order. Outline Dimensions 18 DESCRIPTION 3.17 Terms ITEM General Information CD180AT through CD6900 Accessories and Modifications ITEM DESCRIPTION 21 PUMP MOTORS DC Motors with armature voltages from 105-130 Volts in most cases are used in pump applications. These are special motors built to pump manufacturer specifications. Because of the low armature voltage these motors have special electrical designs and in many cases frame sizes are larger than standard. If a model number is not available, a request for motors in this voltage range must be accompanied by the following information. Pump motors operated from DC potential busses or batteries will show significant speed variations from nominal when the motor is cold and when the applied voltage varies below nominal. Typically Motor RPM will be lower than nameplate speed (approx. 10-15%) when cold and increase to nameplate RPM as main field reaches operating temperature. To reduce the cold to hot speed variations, the shunt fields should be energized at 50-70% of rated voltage to stabilize. However, for ‘emergency’ pump motor applications, where field pre-heating may not be feasible, the pump capacity must be sized to the cold start RPM. Also, at lower than nominal voltage the motor will run slower than nameplate RPM, while conversely the motor will run higher than nameplate RPM when voltage is higher than nominal. For Pump Motor quotations, contact GE. 22 SEALS, DRIVE END SHAFT (horizontal or vertical with shaft up or down) GE offers the following shaft seals: Lip type rubbing seals (which provide protection against oil mist or splash), labyrinth seals (which provide protection against fine abrasive dust), and Inpro® seals (which provide protection from liquids, solids, steam, and slurries of all types). Price addition (per seal) is as follows: Note: For availability and pricing of commutator end shaft seals, refer to GE. Outline Dimensions Accessories & Modifications Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 Motor Frame Size Lip Seal Labyrinth Seal Inpro® Seal CD180AT-CD210AT CD250AT-CD320AT CD360AT-CD5010AY CD6000-CD6200 CD6700-CD6900 $298 $420 $596 Not Available Not Available $298 $490 $838 $1138 $1394 Not Available $2442 $3736 $6900 $8912 23 SEVERE MECHANICAL “A” Severe mechanical duty “A” features are used on applications where motors are subject to severe torsional loads (severe transients, rapid reversals), where additional strength of components is required to resist high electromagnetic forces. Severe mechanical duty “A” features include: • Solid or pinned, laminated commutating poles • High-strength (grade 8) bolts on both main poles and commutating poles; A black oxide finish on these bolts prevents the possibility of hydrogen embrittlement. • The magnet frame is spotfaced for firm seating of these high strength bolts. • Cables are securely anchored with extra lead tying. • Bolted connections at commutating coils and series coils are insulated to prevent chafing of leads that come in contact with those connections. • A cable clamp is used in the conduit box. • A molded insert is located in the lead exit hole to protect leads from threads and other sharp corners. • For CD360AT, CD400AT, CD504AT-CD508AT, high-strength armature banding and epoxy RHP armature varnish is used. Terms Other Application Information Inpro® is a registered trademark of Inpro/Seal Inc., Rock Island, Illinois 3.18 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications Duty “A” Not Available $892 $1136 $1403 $1631 Not Available $2123 $2645 $4439 Not Available Refer to GE Accessories & Modifications Motor Frame Size CDL182AT-CD189AT CD218AT-CD2110AT CD258AT-CD259AT CD287AT-CD288AT CD327AT-CD328AT* CD329AT CD365AT-CD368AT CD407AT-CD409AT CD504AT-CD508AT CD5010AY CD6000-CD6900 Motor Pricing List Price Addition * Subject to engineering approval 24 SHAFT EXTENSIONS 24a Standard Single Shaft Extension. Dimensions will be as shown on dimension prints. 24b Standard Double Shaft Extension. Dimensions will be as shown on dimension prints. 24c Standard Oversize Single Drive End Shaft Extension. Standard shaft extension of the next larger frame diameter for CD210AT-CD360AT. Oversize shafts are not available on Explosionproof Motors. See table in Item 24d for CD400AT and CD500AT frames. On CD5010AY frame, the standard drive end shaft is oversize (4.125 in. dia.), no price addition. For overhung loads, refer to GE. Where standard oversize shaft is used, oversize bearing will also be used (already included in price adder). Use prices listed below. 24d Standard Oversize Double Shaft Extension. Standard double shaft extension of the next larger frame diameter for CD210AT-CD360AT. Oversize shafts are not available on Explosionproof Motors. For overhung loads, refer to GE. Oversize shafts for CD400AT-CD500AT are as follows: CD400AT CD504AT-CD508AT Commutator End Drive End 2.625 3.25 2.875 3.75 Application Information OVERSIZE SHAFT DIAMETER (inches) Frame No additional oversize shaft available. See dimension prints for standard shaft. CD5010AY Accessories & Modifications 23 Cont’d DESCRIPTION Outline Dimensions ITEM General Information CD180AT through CD6900 CAUTION: Belted drives using smaller than standard diameter shafts and/or longer than standard shafts must be referred to GE with complete belt drive data. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.19 Terms 24e Shaft Extension, Special. Special straight extensions on drive end or commutator end or both. The desired dimension must be specified when ordered. The special diameter must not exceed the oversize diameter where an oversize shaft is available. On CD6000 frame the special shaft diameter must not exceed the standard shaft diameter. If required, pricing for oversize bearing must also be added. Other Note: With oversize shafts, the shaft length may be longer and the overall machine length may be longer. Refer to GE for exact dimensions. Accessories and Modifications ITEM DESCRIPTION 24e Cont’d MOTOR LIST PRICE Motor Pricing General Information CD180AT through CD6900 SHAFT EXTENSION a. Standard Single Shaft Extension Accessories & Modifications b. Standard Double Shaft Extension $13219 to $23922 $23923 to $42136 $42137 to $61750 $61751 $98629 $157704 $252289 $403651 to to to to and up $98628 $157704 $252288 $403650 25 26 Furnished as standard on all motors and generators. No price addition for larger frame size generators where double shaft is standard. $70 $82 $96 $150 $244 $352 $420 $594 $676 On CD6000-CD6900, no adder required c. Standard Oversize Single Drive End Shaft Extension Not available on CD180AT frames. $366 $468 $574 $680 $766 $892 Not available on CD6000-CD6900 frames. d. Standard Oversize Double Shaft Extension Not available on CD180AT frames. $732 $936 $1148 $1360 $1532 $1782 Not available on CD6000-CD6900 frames. $488 $680 $788 $972 $1272 $1784 e. Shaft Extension, Special Outline Dimensions Accessories & Modifications $2501 to $3593 to $5579 to $9749 to $3592 $5578 $9748 $13218 List Price Addition $488 $488 $488 $2520 $2520 3.20 $5040 $5040 SHAFT GROUNDING BRUSH A shaft grounding brush is recommended to minimize possible bearing failures caused by shaft voltages. It is mounted externally on the drive end of CD218AT-CD5010AY frames (which reduces usable drive end shaft length by approximately 1 inch) and is mounted internally on the drive end of CD6000-CD6900 frames. Note: The shaft grounding brush and labyrinth seal are furnished as standard with papermill features. Motor Frame Size List Price Addition CD180AT CD210AT CD250AT-CD320AT CD360AT-CD5010AY CD6000-CD6900 Not Available $1448 $1676 $2024 $1186 N/A on C-face, D-flange or P-base motors. Use TACH options. Price addition includes labyrinth seal on CD218AT-CD5010AY frames. See page 3.18, Item 22 for labyrinth seal on CD6000-CD6900 frames. SPACE HEATERS Note: Furnished as standard with crane duty feature Space heaters are installed inside the machine with leads brought out through the standard conduit box. Single phase AC and DC ratings available are 120, 240, and 480 Volts on frames CD180AT-CD6900. Refer to GE for higher voltage. Motor Frame Size Wattage List Price Addition CD180AT-CD210AT CD250AT-CD320AT CD365AT-CD5010AY CD6000-CD6100 CD6200-CD6900 30 75 180 500 1000 $582 $582 $582 $1658 $1658 Terms Other Application Information Up to $2500 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications DESCRIPTION 27 SPEED LIMIT DEVICE Provides for addition of calibrated speed limit device (non-adjustable on frames CD508AT and below and adjustable on frames CD5010AY and above) for motor over speed protection when connected in proper circuit. The device is flange mounted on the commutator end of the motor. Contact will be normally closed on frames CD508AT and below. On frames CD5010AY and above, both normally open and normally closed contacts are provided. The device will be set at the factory to operate at 13-17% above the top rated speed. For special limiting speed, refer to GE. Note: Non-adjustable speed limit devices are not recommended for crane duty use. If adjustable speed limit switch is required on frames CDL182AT-CD508AT, refer to GE. CD182AT-CD508AT CD5010AY-CD6900 List Price Addition a. Speed limit device (mounted) $2534 $5982 b. Speed limit device (mounted) with double shaft extension Refer to GE $5982 $7646 $8480 c. Euclid speed switch Terms Other Application Information Outline Dimensions Speed Limit Devices are available on all frames with a single or double shaft extension. (Frame CD5010AY shown above with double shaft extension.) Accessories & Modifications SPEED LIMIT DEVICE Accessories & Modifications MOTOR FRAME SIZE Motor Pricing ITEM General Information CD180AT through CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.21 Accessories and Modifications ITEM DESCRIPTION 28 SPEED RANGE GREATER THAN STANDARD BY FIELD CONTROL* Provides for increased speed range by field control with constant horsepower output. For top speeds not listed, use the price of the next higher top speed listed. The frame size may be different from standard. On single phase power supply, refer to GE. The overloads to these speeds are defined in page 3.17, Item 20. All Voltages, Continuous or Short Time Rated Dripproof Fully Guarded and Totally Enclosed Motor Pricing General Information CD180AT through CD6900 Accessories & Modifications Base Speed RPM Rated Top Speed RPM HORSEPOWER 3 and Below 5 7.5 10 10 10 10 15 0 10 10 10 15 15 15 0 10 10 10 15 10 10 10 15 10 15 15 15 10 15 15 10 10 15 20 10 15 15 10 10 10 10 15 0 10 10 10 15 15 20 0 10 10 10 20 10 10 10 15 10 15 15 15 10 15 15 10 10 15 20 10 15 15 10 10 10 10 15 0 10 10 10 15 15 20 0 10 15 15 20 10 10 10 15 10 15 15 15 10 15 15 10 15 20 20 10 15 15 10 15 20 25 30 40 50 60 75 100 125 150 200 250 10 15 15 20 0 10 15 20 20 25 10 15 15 15 20 20 15 20 20 15 20 15 0 10 15 20 0 15 20 0 15 20 10 15 20 10 15 PERCENTAGE ADDITION TO LIST PRICE OF BASIC MOTOR 2500 Accessories & Modifications 1750 1500 Outline Dimensions 1150 850 Application Information 650 500 400 Other 300 Terms 250 3500 2500 2900 3000 3500 1900 2300 2600 2900 3100 3200 3400 2000 2300 2550 2900 3450 2000 2200 2550 3400 2000 2200 2550 2600 2000 2200 2500 1600 1900 2200 2400 1200 1500 1800 800 900 1000 1100 1200 1250 1300 1350 1400 1500 10 10 10 10 15 0 10 10 10 15 15 20 0 10 15 15 20 10 10 10 15 10 15 15 15 10 15 15 10 15 20 20 10 15 15 10 10 10 10 15 0 10 10 10 15 15 20 0 10 15 15 20 10 15 15 15 10 15 15 15 10 15 15 10 15 20 20 10 15 15 10 10 10 10 15 0 10 10 15 15 20 20 0 10 15 15 20 10 15 15 20 10 15 15 15 10 15 15 10 15 20 20 10 15 15 10 10 10 10 15 0 10 10 15 15 20 20 0 10 15 15 20 10 15 15 20 10 15 15 15 10 15 15 10 15 20 20 10 15 15 Refer to Factory 10 10 10 10 15 0 10 10 15 15 20 20 0 10 15 15 25 10 15 15 20 10 15 15 15 10 15 15 10 15 20 20 10 15 15 10 10 10 10 20 0 10 15 15 20 25 15 10 15 15 20 0 10 15 15 20 25 20 10 15 15 20 0 10 15 20 20 25 0 10 15 15 25 10 15 15 25 10 15 20 20 10 15 15 10 15 20 20 10 15 20 0 10 15 15 25 10 15 15 25 10 15 20 0 10 20 20 25 10 15 15 25 10 15 20 0 10 20 20 25 10 15 20 0 15 20 20 0 15 20 20 0 15 20 10 20 20 10 20 20 10 15 20 10 15 20 10 15 20 15 15 20 15 15 10 15 20 10 15 20 15 15 20 15 15 20 15 15 20 15 15 10 15 15 10 15 20 20 10 15 20 10 15 15 10 15 20 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 10 15 15 10 15 20 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 15 15 15 10 15 20 15 15 20 10 15 20 15 20 15 20 20 20 10 15 20 15 20 25 15 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 10 15 20 2 2 4 6 8 10 12.5 15 17.5 20 * Contact GE for design verification (affected by ambient, overload, Class B rise, etc.) 3.22 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications DESCRIPTION 28a SPEED RANGE GREATER THAN STANDARD BY FIELD CONTROL Provides for increased speed range by field control with constant horsepower output. For top speeds not listed, use the price of the next higher top speed listed. The frame size may be different from standard. On single-phase power supply, refer to GE. The overloads to these speeds are defined in page 3.17, Item 20. All Voltages, Continuous or Short Time Rated Dripproof Fully Guarded and Totally Enclosed HORSEPOWER 850 650 500 www.gemotors.com 0 10 10 0 10 15 15 15 20 0 0 6 8 12.5 15 17.5 17.5 20 0 4 8 10 12.5 15 17.5 17.5 0 0 4 10 10 12.5 15 17.5 0 0 0 0 4 6 12.5 15 15 17.5 20 • 0 10 10 0 10 15 15 0 10 10 6 10 15 15 0 4 6 8 12.5 15 17.5 17.5 0 4 6 8 12.5 15 17.5 17.5 0 6 8 10 12.5 15 17.5 20 0 4 6 10 12.5 15 4 8 10 12.5 15 17.5 20 0 0 0 4 6 10 12.5 15 17.5 800-541-7191 4 6 10 12.5 400 300 250 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 750 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 710 750 800 900 1000 1100 1200 1250 1300 1350 1400 1500 300 400 500 PERCENTAGE ADDITION TO LIST PRICE OF BASIC MOTOR 0 0 0 6 10 12.5 15 15 17.5 20 0 0 4 6 10 12.5 12.5 17.5 20 22.5 22.5 0 0 2 2 4 6 10 12.5 15 17.5 17.5 20 0 4 4 6 10 12.5 15 17.5 20 0 4 6 8 12.5 15 17.5 20 22.5 0 4 4 6 10 12.5 17.5 20 0 4 4 8 12.5 17.5 20 22.5 0 1 2 2 6 10 15 17.5 17.5 20 20 22.5 0 1 2 4 8 12.5 17.5 17.5 17.5 20 22.5 25 Accessories & Modifications 1900 2000 2200 1800 1900 2000 2100 2200 2300 1500 1600 1700 1800 1900 2000 2100 2200 2300 1500 1600 1700 1800 1900 2000 2100 2200 1400 1500 1600 1700 1800 1900 2000 2100 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Rated Top Speed RPM Accessories & Modifications PERCENTAGE ADDITION TO LIST PRICE OF BASIC MOTOR Base Speed RPM Outline Dimensions 1150 500 Application Information 1500 400 Other 1750 300 Rated Top Speed RPM 0 4 4 6 8 12.5 15 17.5 20 GEP387M 09/11 • Prices and data subject to change without notice. Terms Base Speed RPM HORSEPOWER Motor Pricing ITEM General Information CD180AT through CD6900 3.23 Accessories and Modifications ITEM 29 DESCRIPTION TACHOMETER GENERATOR EQUIPMENT SPEED RANGES The following tachometer generator operating speeds are available with listed items: Motor Pricing General Information CD180AT through CD6900 Type BC42 Accessories & Modifications BC46 Form Y Accessories & Modifications AN-AC Tachometer Output Operating Range 50 Volts/1000 RPM 100 Volts/1000 RPM 50 Volts/1000 RPM 100 Volts/1000 RPM 200 Volts/1000 RPM 50 Volts/1000 RPM 100 Volts/1000 RPM 90 Volts/1000 RPM 100-5000 RPM 100-2750 RPM 100-5000 RPM 100-3600 RPM 100-1800 RPM 100-5000 RPM 100-2500 RPM 100-5000 RPM PY tachometers provide a medium accuracy DC output for use with a regulated drive or for speed indication. AN Series tachometers provide a compact construction with thru-shaft capabilities. The AN Series tachometers can be furnished with either AC or digital output signal for speed regulation or speed indication. (Type AN-DG tachometer shown above.) Terms Other Application Information Outline Dimensions BC tachometers produce DC output to provide high accuracy speed regulation or speed indication. 3.24 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications ITEM General Information CD180AT through CD6900 DESCRIPTION 29 Cont’d MOTOR FRAME SIZE MOTOR MOUNTED, DIRECT CONNECTED TACHOMETERS CDL182AT-CD5010AY CD6000-CD6900 Motor Pricing List Price Addition Accessories & Modifications OUTLINE PAGE ___ TYPE BC A DC tachometer for high accuracy speed-indicating and/or speed-regulating applications. The tachometer generator is flange mounted, rabbeted to the commutator endshield, and is coupled with an antibacklash coupling to the motor shaft extension. The BC tachometer generators will have a footed frame and commutator end extension covered by a thimble. This allows belt driving a second tachometer mounted on the BC feet and simplifies customer tachometer standardization. Any other arrangement should be referred to GE. Note: A double shaft extension is not available on severe duty or explosion proof BC tachometers. Type BC BC42, 50 or 100 Volts/1000 RPM BC46, 50, 100 or 200 Volts/1000 RPM $7440 $10008 $8333 $11209 $8194 $10728 $9117 $11562 BC42, 50 or 100 Volts/1000 RPM $10400 $11645 Mounting kit is assembled to motor and is only for flange mounted BC tachometer. (This includes coupling, stub shaft, and mounting bracket for BC tach.) For explosionproof tachometer to be mounted on explosionproof motor, refer to page ___. $1666 $2500 BC42, 100 Volts/1000 RPM BC46, 100 Volts/1000 RPM Accessories & Modifications Type BC, Waterproof or Dustproof 5PY59JY, 50 or 100 Volts/1000 RPM (max speed 2500 RPM) $4925 $5516 Mounting kit is assembled to motor and is only for flange mounted PY tachometer. (This includes coupling, stub shaft, and mounting bracket for Form Y.) $1666 $2500 Application Information OUTLINE PAGE ___ FORM Y, DC A DC tachometer for medium accuracy speed-indicating and/or speed-regulating applications. The tachometer generator is flange mounted and rabbeted to the commutator endshield, and is coupled with an antibacklash coupling to the motor shaft extension. (Not available as waterproof.) OUTLINE PAGE ___ $1784 $4222 Other TYPE AN-AC An AC tachometer for medium accuracy speed-indicating or for use with some speedregulating systems. The tachometer generator is flange mounted and rabbeted to the commutator endshield. (Not available for separate mounting or belt connection.) 45/90 Volts/1000 RPM (For frames CD180AT-CD6200 only, including CD180AT and CD210AT TEFC enclosures.) Outline Dimensions Type BC, Explosionproof (Class I, Group D, Class II, Groups E, F, G) CD180AT and CD210AT TEFC motors suitable only for AN tachometer mounting on commutator end. Terms Not available on CD6700-CD6900. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.25 Accessories and Modifications ITEM 29 Cont’d Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 DESCRIPTION MOTOR MOUNTED, DIRECT CONNECTED TACHOMETERS List Price Addition Avtron AV85 THIN-LINE II™ (Replaces M85) Style tachometer/encoder. Mounts on 8.8" accessory flange. No bearings, couplings, or adapters. Magnetoresistive (MR) sensors, Wide-Gap technology, full wiring protection and LED diagnostics. OUTLINE PAGE ___ Accessories & Modifications Outline Dimensions Environmental Rating 240, 600, 1024, 1200 pulses/revolution, single output $3285 $5805 240, 600, 1024, 1200 pulses/revolution, dual output $5468 $7988 2000, 2048, 4096, 5000 pulses/revolution, single output $3641 $6156 2000, 2048, 4096, 5000 pulses/revolution, dual output $6174 $8690 OUTLINE PAGE ___ 240, 600, 1024, 1200 pulses/revolution, single output $5945 $5945 240, 600, 1024, 1200 pulses/revolution, dual output $8721 $8721 2000, 2048, 4096, 5000 pulses/revolution, single output $6080 $6080 2000, 2048, 4096, 5000 pulses/revolution, dual output $9000 $9000 TYPE AN-DG Avtron AV850 SMART Tach II™ (Replaces AN-DG, M193B, M285) Mounts on 8.5" accessory flange. No bearings, couplings or adapters. MR sensors, Wide-Gap technology, full wiring protection and LED diagnostics. Removable sensors. Shaft grounding brush option or permits thru-shafts up to 4.5" Application Information CD6000 MODEL NUMBER AND DESCRIPTION Avtron AV485 SMART Tach II™ (Replaces M3 and M4 solid-shaft, M385, M485, M785) Style tachometer/encoder. NEMA 56C motor face mount (like BC). MR sensors, full wiring protection and LED diagnostics, removable sensors. Heavy Duty Industrial Applications with frequent exposure to temperatures variations and contamination. Paper, metals processing, plastics, textiles, food, petrochemical, machine tool, marine duty, material handling Severe Duty Industrial Applications with constant exposure to temperature variations and contamination, and increased physical demands occur. Paper, primary metals, petrochemical, mining, dockside cranes, marine duty, wash down; Ideal for MD style motors. OUTLINE PAGE ___ 240, 600, 1024, 1200 pulses/revolution, single output $4824 $6480 240, 600, 1024, 1200 pulses/revolution, dual output $7034 $8690 2000, 2048, 4096, 5000 pulses/revolution, single output $4959 $6620 2000, 2048, 4096, 5000 pulses/revolution, dual output $7308 $8969 Add shaft grounding brush to AV850 $878 $2534 Avtron AV685 SMART Tach II™ (Replaces M685) Mounts on stub shaft (tethered). MR sensors, full wiring protection and LED diagnostics, removable sensors. Other MOTOR FRAME SIZE CD180AT-CD5010AY OUTLINE PAGE ___ 240, 600, 1024, 1200 pulses/revolution, single output $6881 $6881 240, 600, 1024, 1200 pulses/revolution, dual output $9338 $9338 2000, 2048, 4096, 5000 pulses/revolution, single output $7187 $7187 2000, 2048, 4096, 5000 pulses/revolution, dual output $9950 $9950 Add shaft grounding brush to AV685 $1319 $1319 Heavy Duty Industrial Applications with frequent exposure to temperatures variations and contamination. Paper, metals processing, plastics, textiles, food, petrochemical, machine tool, marine duty, material handling. Severe Duty Industrial Applications with constant exposure to temperature variations and contamination and increased physical demands occur. Paper, primary metals, petrochemical, mining, dockside cranes, marine duty, wash down. Ideal for MD style motors. Terms Notes: Avtron AV850 SMART Tach II™ can not be mounted on CD250AT-CD320AT frames with a TEFC enclosure. Use a TENV or TEAO enclosure. Avtron AV850, AV485 can not be mounted on CD180AT and CD210AT TEFC motors. Use a TENV enclosure. Integral end of shaft grounding brush, add $2232 list to the above prices. Not available on tachs with thru shafts. (ppr) pulses per revolution, required at time of order 3.26 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications MOTOR FRAME SIZE CD6000 OUTLINE PAGE ___ Environmental Rating 240, 512, 600, 1024, 1200 pulses/revolution, single output $4229 $4829 240, 512, 600, 1024, 1200 pulses/revolution, dual output $5227 $5899 Northstar RIM Tach™ 6200 Foot mount or accessory bracket 56 C-face mount (mounts same as BC style tachs). Magnetoresistive sensors, ductile iron enclosure, polymer rotor, industrial connector, extra severe duty bearings for long life. The RIM Tach 6200 is a close coupled design. Features replaceable sensor modules. OUTLINE PAGE ___ 240, 512, 600 pulses/revolution, single output $4219 $4852 240, 512, 600 pulses/revolution, dual output $5218 $6001 1024, 1200 pulses/revolution, single output $4944 $5686 1024, 1200 pulses/revolution, dual output $5942 $6834 2048 pulses/revolution, single output $5251 $6039 2048 pulses/revolution, dual output $6250 $7188 Northstar RIM Tach™ 1250 Mounts on 12.5" accessory flange. No bearings, couplings, or adapters needed. Magnetoresistive sensors, ductile iron enclosure, polymer rotor and industrial connector. For a through shaft or end of shaft mountings the RIM Tach 1250 can fit up to a 8.0" diameter shaft. Features replaceable sensor modules. Used on CD6000’s. Motor Pricing List Price Addition Northstar RIM Tach™ RT8 (Replaces RIM 8500) Mounts on 8.5" accessory flange. No bearings, couplings, or adapters needed. Magnetoresistive sensors, ductile iron enclosure, polymer rotor and industrial connector. For through shaft or end of shaft mountings, the RIMTach RT8 can fit up to a 4.5" diameter shaft. Features replaceable sensor modules. Mill Duty Industrial Applications with temperatures between -40ºC and +80ºC, chemical resistance include salt spray, most solvents, mild acids and bases. Paper, metal finishing, plastics, textiles, converting, machine tools, material handling. OUTLINE PAGE ___ 240, 512, 600, 1024, 1200 pulses/revolution, single output N/A $5554 240, 512, 600, 1024, 1200 pulses/revolution, dual output N/A $6557 2048 pulses/revolution, single output N/A $9994 2048 pulses/revolution, dual output N/A $10992 Mill Duty Industrial Applications with temperatures between -40ºC and +80ºC, chemical resistance include salt spray, most solvents, mild acids and bases. Paper, metal finishing, plastics, textiles, converting, machine tools, material handling. Other Notes: Northstar RIM Tach™ RT8 can not be mounted on CD180AT-CD320AT frames with a TEFC enclosure. Use a TENV or TEAO enclosure. The Northstar RIM 1250, 6200 and SLIM Tach™ SL85 and HS56 all have sealed electronics to prevent contaminant intrusion. Shaft grounding brush, add $2232 list to the above prices. All items listed above are CE approved. (ppr) pulses per revolution, required at time of order Accessories & Modifications MODEL NUMBER AND DESCRIPTION Accessories & Modifications CD180AT-CD5010AY Outline Dimensions MOTOR MOUNTED, DIRECT CONNECTED TACHOMETERS Terms 29 Cont’d DESCRIPTION Application Information ITEM General Information CD180AT through CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.27 Accessories and Modifications ITEM 29 Cont’d Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 DESCRIPTION MOTOR MOUNTED, DIRECT CONNECTED TACHOMETERS Accessories & Modifications CD6000 MODEL NUMBER AND DESCRIPTION List Price Addition Northstar SLIM Tach™ SL85 (formerly LakeShore) Mounts on 8.5" accessory flange. No bearings, couplings, or adapters needed. Magnetoresistive sensors, ductile iron enclosure, polymer rotor and industrial connector. For through shaft or end of shaft mountings, the SLIM Tach SL85 can fit up to a 3.75" diameter shaft. Approx. half the thickness of the RIM 8500. The SL85 does not have replaceable sensor modules. Through shaft models are also available for shafts ranging from .5" through 3.75" in diameter. OUTLINE PAGE ___ Environmental Rating 64, 128, 256, 512, 1024 pulses/revolution, single output $2362 N/A 64, 128, 256, 512, 1024 pulses/revolution, dual output $4061 N/A 2048 pulses/revolution, single output $2530 N/A Northstar SLIM Tach™ HS56 (formerly LakeShore) Hollow shaft design allows for mounting when an accessory flange is not available. Mounts on a standard shaft extension or stub shaft. Magnetoresistive sensors, polymer rotor and industrial connector. SLIM Tach HS56 can fit up to a 1.125" diameter shaft. Outline Dimensions MOTOR FRAME SIZE CD180AT-CD5010AY Heavy Industrial Industrial Applications with temperatures between -40°C and +80°C, chemical resistance include salt spray, most solvents, mild acids and bases. SL85 can be used in a Mill Duty environment. OUTLINE PAGE ___ 64, 128, 256, 512, 1024 pulses/revolution, single output $2606 $2867 64, 128, 256, 512, 1024 pulses/revolution, dual output $3821 $4203 2048 pulses/revolution, single output $2770 $3048 2048 pulses/revolution, dual output $4152 $4567 Industrial Duty Industrial Applications with temperatures between -20°C and +80°C, chemical resistance include salt spray, most solvents, mild acids and bases. Notes: Northstar RIM Tach™ RT8 can not be mounted on CD180AT-CD320AT frames with a TEFC enclosure. Use a TENV or TEAO enclosure. The Northstar RIM 1250, 6200 and SLIM Tach™ SL85 and HS56 all have sealed electronics to prevent contaminant intrusion. Shaft grounding brush, add $2232 list to the above prices. All items listed above are CE approved. (ppr) pulses per revolution, required at time of order Application Information Dynapar HA625 Encoder Flange mounted Tach, 5-26 VDC input, push-pull and differential line driver, 5-26 VDC, single output, NEMA 4/IP66 sealed enclosure, side mount MS style connector (10 pin mating connector included) over voltage protection, output short circuit protection, and reverse voltage protection, 85°C operating temperature, CE labeled. 240, 512, 600, 1024, 1200, 2048 pulses/revolution Heavy Industrial Industrial Applications with temperatures between 40°C and +80°C. $1392 Dynapar H56 Rotopulser (Replaces the 62P) 56C face mounted tach (mounts same as BC series tachs). Heavy mill duty enclosure, 5-26 VDC input, push-pull and differential line driver, 5-26 VDC, single output, pluggable screw terminals (Industrial connectors) mating connector(s) included. Other OUTLINE PAGE ___ $1532 OUTLINE PAGE ___ 240, 512, 600, 1024, 1200, 2048 pulses/revolution, single output $3536 $3890 240, 512, 600, 1024, 1200, 2048 pulses/revolution, dual output $3951 $4346 Heavy Mill Duty Industrial Applications with temperatures between -40°C and +80°C NEMA 4/IP66 enclosure. Suitable for severe duty in paper, steel and lumber mills. Terms Notes: The HA625, H56 and X25 require a Tach mounting kit. (Tach mounting kit consists of Tach adapter, coupling and stub shaft). The H56 can also be foot mounted. The HA625, H56 and X25 can not be mounted on CD180-CD210 TEFC motors. Use TENV enclosure. (ppr) pulses per revolution, required at time of order 3.28 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications MOTOR FRAME SIZE CD6000 MODEL NUMBER AND DESCRIPTION List Price Addition Dynapar HS35R Sealed Hollow Shaft Hollow shaft encoder is designed for easy installation onto the motor, the unit sealed as well as equipped with an unbreakable disk that meets the demands of the most severe shake and vibration, the unit is electrically and thermally isolated, shaft seals at both ends, dust cover included. 5-26 VDC input, push-pull and differential line driver, 5-26 VDC output. OUTLINE PAGE ___ 240, 512, 600, 1024, 1200, 2048 pulses/revolution Industrial Industrial Applications with temperatures between -40°C and +70°C $1200 Accessories & Modifications 240, 512, 600, 1024, 1200, 2048 pulses/revolution, single output Dynapar X25 Explosionproof Flange mounted tach, UL listed for Class 1, Division 1 & 2, Groups C, D, E, F, G locations, 5-26 VDC input, push-pull and differential line driver, 5-26 VDC output, single output 1/2-14 NPTF conduit entry. Heavy industrial enclosure. Environmental Rating Motor Pricing CD180AT-CD5010AY $1325 OUTLINE PAGE ___ Explosionproof Industrial Applications with temperatures between 0°C and +70°C $3360 $3864 Accessories & Modifications MOTOR MOUNTED, DIRECT CONNECTED TACHOMETERS Notes: The HA625, H56 and X25 require a Tach mounting kit. (Tach mounting kit consists of Tach adapter, coupling and stub shaft). The H56 can also be foot mounted. The HA625, H56 and X25 can not be mounted on CD180-CD210 TEFC motors. Use TENV enclosure. (ppr) pulses per revolution, required at time of order CUSTOMER SUPPLIED TACHOMETERS Customer-supplied tachometers will not be tested. Drawings and parts list of customer-supplied tachometers must be received at the time of order. Both the tachometer and shipping papers must be tagged with the GE order and item number. Refer to customer-supplied material section (page 3.12, Item 14) for additional information. MOTOR FRAME SIZE MOTOR MOUNTED, DIRECT CONNECTED TACHOMETERS CD180AT-CD5010AY CD6000 For mounting only of a customer-supplied Type C-Face tachometer. (This includes coupling, stub shaft, mounting bracket, and assembly of tachometer.) $3024 $3858 For mounting kit only for customer-mounted Type C-Face tachometer. (This includes coupling, stub shaft, and mounting bracket.) Mounting kit is assembled to the motor. $1666 $2500 Application Information List Price Addition TERMINAL BOARD IN CONDUIT BOX Generally, all power, field and other internal accessory terminals will be located on a terminal board in the conduit box. On some higher current machines, the field and other internal accessory terminals will be located on a terminal board, but the power leads will be fixed and supported separately (all within the conduit box). On machines rated 2,000 amps or more, the field and other internal accessory terminals will be located on a terminal board and the power leads will be fixed and supported separately as standard (all within the conduit box.) Motor Frame Size Shunt Wound Stabilized Shunt or Compound Wound CD218AT-CD5010AY CD6000-CD6900 $1200 No Price Addition $1500 Not Available Terms 30 Note: Not available for explosionproof motors. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Outline Dimensions 29 Cont’d DESCRIPTION Other ITEM General Information CD180AT through CD6900 3.29 Accessories and Modifications ITEM 31 Motor Pricing General Information CD180AT through CD6900 DESCRIPTION TESTS AND CURVES AVAILABLE FOR CD180-CD5010 FRAME AND CD6000 FRAME MOTORS Routine Test Accessories & Modifications Neutral Check Winding Resistance High Potential Commutation Check Voltage Regulation Vibration Test Saturation Curve No Load Speed Running Full Load Motor Generator YES YES YES YES NO YES NO YES YES YES YES YES YES YES YES YES NO YES Complete Test Motor Generator Neutral Check Full Load Heat Run Winding Resistance High Potential Commutation Adjustment Saturation Curve Voltage Regulation Running Full Load YES YES YES YES YES NO NO YES YES YES YES YES YES YES YES YES Speed Regulation (base speed and top weak field speed) YES NO Accessories & Modifications CHARGES Tests Net Price Addition Outline Dimensions A. Certified Test Report - Electrically duplicate machine previously tested B. Unwitnessed Routine Test - 5 copies of certified test reports C. Witnessed Routine Tests - 5 copies of certified test reports D. Unwitnessed Complete Test - 5 copies of certified test reports E. Witnessed Complete Test - 5 copies of certified test reports Curves Net Price Addition $300 net $300 net Terms Other Application Information A. Speed and Torque vs Load Current Curve B. HP and Efficiency vs Load Current Curve $300 net per motor $300 net per motor $1800 net per motor; Add 2 weeks lead time $4250 net per motor; Add 2 weeks lead time $5500 net per motor; Add 3 weeks lead time 3.30 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications 32 TEMPERATURE DETECTORS A bimetallic temperature-sensing device is mounted on the commutating coil. The device is available with normally open or normally closed contactors. Specify whether normally open or normally closed contacts are required. (Included as standard on TEUC motors). Thermostats are typically normally closed and the opening temperature is between 120°C to 150°C. Thermostats with special temperature rating are non-standard. Refer to GE when required. Maximum Current Ratings (Normally open or normally closed contacts) Load 125V AC 250V AC 600V AC 30V DC Resistive 5 Amps 2.5 Amps Inductive* 3 Amps 1.5 Amps 1 Amp 0.5 Amp (Do not use above 600V AC) 5 Amps 1.5 Amps (Do not use above 30V DC) * Suitable for pilot duty only (relay coils) For the following types of temperature detectors mounted in the locations indicated, see below for pricing. Price does not include electronic sensor module. Commutator Field or Shunt Field List Price Addition a. Thermostats b. Thermistors (PTC Type) c. Resistance Temperature Detectors (RTD) Copper - 10 Ohm Platinum - 100 Ohm Nickel - 120 Ohm d. Thermocouples (Type J) $310 $450 $2266 $4532 $2266 $2266 $900 $1800 $900 Not Available VERTICAL MOUNTING (FOOTED) The following applies to vertically-operated foot- or flange-mounted, standard ball bearing, motors where no external thrust is reflected back to the motor shaft. Refer to GE for external thrust limitations. For vertical brake applications, refer to Modification Item 8a. Note: For crane motors, refer to page 3.11, Item 13. All dripproof and splashproof motors which are mounted vertically require non-standard covers (the louvers are rotated to provide protection in the vertical position). Totally enclosed motors require no modifications to the covers. Frames CD180AT-CD320AT do not require internal modification for vertical mounting. Thus, a standard motor in these frame sizes is suitable for vertical mounting. Frames CD360AT-CD6900 require internal modification for vertical mounting. Thus, a standard motor in these frame sizes is not suitable for vertical mounting. The CD365AT-CD5010AY frames require shaft seals for vertical mounting with the shaft down. The CD365AT-CD5010AY frames mounted shaft up require additional modifications to the bearings and shaft. Refer to GE for applications involving vertical mounting of CD6000-CD6900 frames. Enclosure Vertical Shaft Down Vertical Shaft Up CD180AT-CD320AT CD365AT-CD5010AY DP Add 2% Add 2% + $596 TE No Price Addition* Add 2% + $596* DP Add 2% No Price Addition Add 2% + $1050 TE CD6000-CD6900 Refer to GE Add 2% + $1050 Terms 33 Not Available Not Available Notes: DP Dripproof TE Totally Enclosed * If TEFC waterproof, contact GE For CD180AT, will not meet NEMA definition for DPFG, the motor is considered “fully guarded”. (Refer to page 3.16, Item 17 for C-Face and D-Flange pricing.) www.gemotors.com • 800-541-7191 Outline Dimensions Bearing Application Information TEMPERATURE DETECTORS Accessories & Modifications LOCATION Other Thermostat ratings for DPFG and TE motors (standard on TEAAC, TEWAC and explosionproof motors) Motor Pricing DESCRIPTION Accessories & Modifications ITEM General Information CD180AT through CD6900 GEP387M 09/11 • Prices and data subject to change without notice. 3.31 Accessories and Modifications ITEM 34 DESCRIPTION VOLTAGES 34a Armature, Non-Standard Provides for special armature voltages, with same speed range and operating characteristics as standard ratings. Frames may be different than standard. VOLTAGES, ARMATURE (NON-STANDARD) Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 Voltage HP Base Speed RPM 120 105-130 1-3 1150-3500 Contact GE ALL ALL ALL 300-1150 ALL ALL ALL 1-250 300-2000 7 1/2-4500 500-1000 1250-4500 300-1000 1250-4500 550 600 700 Outline Dimensions Accessories & Modifications 750 Application Information No price addition No price addition Add 3% No price addition Add 6% No price addition Add 6% Add 3% Note: For voltages not listed in the table, refer to GE with application requirements, including type of power supply, speed range by field control, and armaturevoltage control. 34b Field, Standard The following field voltages are standard. Voltages listed are nominal values. For more exact values, refer to GE. Standard Armature Voltages Standard Field Voltages (Frames CD5010AY and Below) Standard Field Voltages (CD6000-CD6900 frames) 180 240, 500, 700 100, 200 120, 150, 240, 300 — 120, 150, 200, 240, 300 34c Field, Non-Standard Non-standard field voltages can be obtained by using the standard fields and adding a series resistance. For non-standard field voltages and pricing, refer to GE. 35 WARRANTY EXTENSION The standard warranty for Kinamatic motors is 24 months from title transfer to third party, and 30 months from shipment by seller, whichever occurs first. The CD6000 standard warranty is 12 months from title transfer to 3rd party, and 18 months from shipment by seller, whichever occurs first. Extended warranties are available as follows: 35a Kinamatic Warranty Extension From Title Transfer to 3rd Person From Shipment by Seller List Price Addition 36 months 42 months Add 3% of Motor NET Price 35b CD6000 Series Warranty Extension From Title Transfer to 3rd Person From Shipment by Seller List Price Addition 24 months 30 months Add 3% of Motor NET Price Terms Other List Price Addition 3.32 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications 36 WINDINGS, STABILIZED SHUNT, COMPOUND OR SERIES Stabilized shunt, compound, or series windings are not available on frames CD329AT, CD6700, CD6800 and CD6900. These frames are only available with shunt wound fields. Also not available on some CD328AT frames. Refer to GE for all design verification. Standard motors are shunt wound. Where speed regulation greater than that provided by shunt wound is required, a compound or stabilized shunt wound motor may be specified. Standard compound wound motors will have approximately 15-25% speed regulation at rated speed. For other degrees of compounding, refer to GE. WARNING: Series motor excitation is entirely dependent on load. The application of series motors should be avoided where the load may drop below 25% rated torque or where the load is not solidly coupled, since the motor may overspeed. Standard base speeds of series wound motors are different than shunt wound motors. Refer to GE for exact speeds. MOTOR LIST PRICE DESCRIPTION Up to $2500 $3593 to $5578 $5579 to $9748 $9749 $13219 $23923 $42137 $61751 $98629 $157704 $252289 to to to to to to to to $13218 $23922 $42136 $61750 $98628 $157704 $252288 $403650 $403651 and up Outline Dimensions Accessories & Modifications CAUTION: Compound wound motors are generally not suited to applications requiring speed control by field weakening. In no case should the field be weakened more than enough to obtain 125% of rated speed. When use with field weakening is intended, the order must specify the speed range. The nameplate will show maximum allowable speed. $2501 to $3592 Motor Pricing DESCRIPTION Accessories & Modifications ITEM General Information CD180AT through CD6900 For Stabilized Shunt, Compound or Series Windings* $244 $244 $330 $424 $516 $690 $892 $1540 $2430 $4860 $9720 $19440 Not Available Terms Other * For frames where this is not available, see above. Application Information List Price Addition www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.33 Accessories and Modifications General Information CD180AT through CD6900 ITEM 37 DESCRIPTION MOD SHOP PRICING FRAME SIZE Terms Other Application Information Outline Dimensions Accessories & Modifications Accessories & Modifications Motor Pricing Modification CD180AT CD210ATCD280AT CD320AT CD360AT CD400AT CD500ATCD5010AY Mod Shop Fee $250 $320 $650 $720 $1200 $1600 Standard C-Face Endshield (Specify 4.5" or 8/5" for CD180AT) Conduit Box: Condulet Off Main Conduit Box (for accessory leads) Waterproof Covers: Transparent* (Lucite® or equivalent) Transparent* (Lexan® or equivalent) Auxiliary or Customer Nameplate Enclosure Conversions: DPFG-BV (Blower, with filter, mounted on comm end only) - 230/460 Volt, 60Hz DPFG (Self-Ventilated - Motor must have internal fan, Contact GE) DPFG-SV (Separately Ventilated on comm end only) SPFG Splashproof Fully Guarded (add for Blower as required) Sliding Base (Horizontal mounting only) Transition Base (Horizontal mounting only) Space Heater (120V AC Standard - Inquire for optional voltages) Tachometers (Analog) Type AN-AC 45 or 90V/1000 RPM Form Y (PY), DC 50 or 100V/1000 RPM (max speed 2500 RPM) Type BC - BC42, 50 or 100V/1000 RPM - BC46, 50, 100, or 200V/1000 RPM Type BC Waterproof or Dustproof - BC42, 100V/1000 RPM - BC46, 100V/1000 RPM Tachometers (Digital) Avtron AV850 SMART-Tach II™ (Type AN-DG) (HD) - 240, 600, 1024, or 1200 ppr, single output - 240, 600, 1024, or 1200 ppr, dual output Northstar RIM Tach™ RT8A - 240, 512, 600, 1024, or 1200 ppr, single output - 240, 512, 600, 1024, or 1200 ppr, dual output Tachometer Mounting Only Form Y (PY) Mounting Kit Only Assembled to Motor - Includes Coupling, Stub Shaft, Mounting Bracket for PY Type C-Face Tachometer Mounting Kit Only Assembled to Motor - Includes Coupling, Stub Shaft, Mounting Bracket Mounting Customer-supplied C-Face tachometer - Includes Coupling, Stub Shaft, Mounting Bracket Vertical (Frame will be supplied with feet) $200 $725 $1200 $3000 N.A. N.A. $605 $495 $605 $495 $605 $495 $825 $990 $825 $990 $825 $990 $300 $600 $60 $300 $600 $60 $450 $900 $60 $450 $900 $60 $450 $900 $60 $450 $900 $60 $1600 $300 $300 $300 $300 $450 $640 $2850 $300 $300 $300 $450 $900 $640 $3150 $600 $600 $600 $600 $1200 $640 $3500 $600 $600 $600 $1100 $2200 $640 $4100 $600 $600 $600 $2000 $4000 $640 $5250 $1200 $1200 $1200 $2600 $5200 $640 $1975 $5400 $1975 $5400 $1975 $5400 $1975 $5400 $1975 $5400 $1975 $5400 $8175 $11000 $8175 $11000 $8175 $11000 $8175 $11000 $8175 $11000 $8175 $11000 $9025 $11800 $9025 $11800 $9025 $11800 $9025 $11800 $9025 $11800 $9025 $11800 $5300 $7750 $5300 $7750 $5300 $7750 $5300 $7750 $5300 $7750 $5300 $7750 $4650 $5750 $4650 $5750 $4650 $5750 $4650 $5750 $4650 $5750 $4650 $5750 $1850 $1850 $1850 $1850 $1850 $1850 $1850 $1850 $1850 $1850 $1850 $1850 $3325 $3325 $3325 $3325 $3325 $3325 * Not Available on all CD180AT frames or CD210AT TEFC Frames 3.34 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessories and Modifications ITEM General Information CD180AT through CD6900 DESCRIPTION D450 5CD184TA094B070 Motor List Mod Shop Fee Lexan Covers $18,098 Motor Pricing 37 Pricing Example Cont’d $650 $900 $640 Mod Motor List $21,050 GO-2A Multiplier x 0.5 Mod Motor Net $10,525 Accessories & Modifications 120V Space Heater Accessories & Modifications Additional Information: 1. MOTOR – List price from GE Standard Products Catalog or Elitenet 2. MOD SHOP FEE – List price per the appropriate frame size from the top row of this price list 3. MODIFICATION LIST PRICE – Add price(s) for all modifications from the price list 4. GE MULTIPLIER SYMBOL – Use your appropriate multiplier based on multiplier symbol for stock motor 5. MULTIPLIER TIMES TOTAL LIST = NET PRICE If you have any questions, or require a modification that is not listed, please contact your GE Sales Representative or call 800-541-7191. Terms Other Application Information Outline Dimensions Pricing subject to change without notice. Verify pricing and lead time with your GE Sales Representative at time of order. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.35 Accessories and Modifications Notes Terms Other Application Information Outline Dimensions Accessories & Modifications Accessories & Modifications Motor Pricing General Information CD180AT through CD6900 3.36 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Outline Dimensions 6000 to 6900 . . . . . . 6000 to 6900 . . . . . . 6000 to 6200 . . . . . . 6700 to 6900 . . . . . . www.gemotors.com • . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.19 4.20 4.21 4.22 4.23 4.24 4.25 4.26 4.27 4.28 4.29 4.30 4.31 4.32 4.33 4.34 4.35 6000 to 6200 . . . . 6700 to 6900 . . . . 6050 to 6066 . . . . 6154 to 6177 . . . . 6259 to 6280 . . . . 6766 to 6785 . . . . 6873 to 6896 . . . . 6977 to 6999 . . . . 180AT to 5010AY . . 6000 to 6900 . . . . 180AT to 500AT . . . and 6000 to 6900 180AT to 500AT . . . and 6000 to 6900 180AT to 6900 . . . . 180AT to 6900 . . . . 180AT to 6900 . . . . 180AT to 6900 . . . . CD180AT to CD6900 CD180 to CD6900. . CD180 to CD6900. . 180AT to 6900 . . . . 180AT to 6900 . . . . . . . . . . . . . . . . . . . . . . . . . . TEWAC . . . . . . . . . TEWAC . . . . . . . . . Air Openings . . . . . . Air Openings . . . . . . Air Openings . . . . . . Air Openings . . . . . . Air Openings . . . . . . Air Openings . . . . . . Accessory Mountings Accessory Mountings Accessory Couplings. . . . . . . . . . . . . . . . . . . . . . . 4.40 4.41 4.42 4.43 4.44 4.45 4.46 4.47 4.48 4.49 4.50 . . Accessory Adapters . . . 4.51 . . . . . . . . . . . . . . . . . . Speed Limit Device . . . . Avtron Tachometer. . . . Avtron Tachometer. . . . Type AN Tachometer . . Northstar Tachometer. . Northstar Tachometer. . Dynapar Encoder. . . . . Dynapar Rotopulse. . . . eXcellon® Type BC . . . . Tachometer 180AT to 6900 . . . . . . eXcellon® Form Y . . . . . Tachometer 180AT to 500AT . . . . . Sliding Base . . . . . . . . CD210AT to CD500AT . Soleplates . . . . . . . . . CD6050 to CD6280 . . . Soleplates . . . . . . . . . CD6766 to CD6999 . . . Soleplates . . . . . . . . . NEMA Mounting Configurations . . . . . . . . . . . 4.52 4.53 4.54 4.55 4.56 4.57 4.58 4.59 4.60 Motor Pricing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modifications Pricing DPFG, TENV . . . . DPFG, TENV . . . . DPFG, TENV . . . . DPFG, TENV . . . . TEFC . . . . . . . . . TEFC . . . . . . . . . TEFC . . . . . . . . . TEFC . . . . . . . . . DPFG, TENV . . . . DPFG, TENV . . . . DPFG, TENV . . . . TEFC . . . . . . . . . TEFC . . . . . . . . . DPFG, TENV . . . . DPFG, TENV . . . . Conduit Box . . . . TEFC . . . . . . . . . Explosionproof . . Explosionproof . . TEAAC . . . . . . . . TEAAC . . . . . . . . TEAO . . . . . . . . Air Openings . . . . Blower Ventilated. Blower Ventilated. Blower Ventilated. Blower Ventilated. DPFG-SV, ESV . . . DPFG-SV, ESV . . . DPFG-SV, ESV . . . DPFG-SV, ESV . . . DPFG-SV, ESV . . . DPFG-SV, ESV . . . Blower Ventilated, No Filter Blower Ventilated, With Filter Splashproof, . . . . Blower Ventilated TEAAC . . . . . . . . TEAAC . . . . . . . . Page Accessories & Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outline Outline Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frame Size 4.61 4.62 4.63 4.64 4.65 4.66 Application Information L182AT to 189AT. . . L182ACY to 189ACY L182ATC to 189ATC. L182ATD to 189ATD L182AT to 189AT. . . L182ACY to 189ACY L182ATC to 189ATC. L182ATD to 189ATD 218AT to 329AT . . . 218ATC to 329ATC . 218ATD to 329ATD . 218AT to 2110AT . . 258AT to 328AT . . . 365AT to 5010AY . . 365ATD to L508ATD 365AT to 5010AY . . 365AT to L409AT . . 188AT to 409AT . . . 188ATC to 189ATC . 366AT to L508AT . . 5010AY . . . . . . . . 327AT to L508AT . . 210AT to 5010AY . . 180AT to 280AT . . . 320AT . . . . . . . . . 360AT to 400AT . . . 500AT . . . . . . . . . 6050 to 6066 . . . . 6154 to 6177 . . . . 6259 to 6280 . . . . 6766 to 6785 . . . . 6873 to 6896 . . . . 6977 to 6999 . . . . 6000 to 6900 . . . . Page Other Outline . . . . 4.36 . . . . 4.37 Terms Frame Size General Information Index . . . . 4.38 . . . . 4.39 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.1 Frames L182AT to 189AT Dripproof Fully Guarded and Totally Enclosed Nonventilated General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END DRIVE END FC KEY .1875 X .1875 .88 LONG Accessories & Modifications 22.5° R5.20 .14 2.25 3 KEY .25 X .25 X 1.38 LG 2.00 3 .8750 .8745 1.1250 1.1245 R4.92 8.93 4.50 4.47 4 2 4 2.00 (4) HOLES .4062 DIA. 2F 2.76 1.50 3.75 B MAX .38 7.50 8.90 MAX. Commutator end shaft extension is furnished only when ➀ Splashproof fully guarded machines will have additional covers, increasing the overall width at the commutator end and drive end pg102 specifically ordered. side air openings. Shaft runout shall not exceed 0.002 inch total indicator reading. ➁ Dripproof, fully guarded vertical drive end shaft down machines will The standard single shaft machine has the commutator end bearing have additional covers, increasing the overall width and exceeding bracket and shaft extension prepared to accept accessories. For bottom of mounting feet at the commutator end openings. additional information, see page 4.48. ➂ Represents minimum length of shaft available for hubs. ➃ Air openings for dripproof fully guarded. Totally enclosed machines will not have openings. Application Information Outline Dimensions 2.39 .75 NPT FOR CONDUIT 1.50 Modifications Pricing Motor Pricing .20 1.44 8.88 CONDUIT HOLE BS 1.75 1 1 1.44 C Frame Approx. Wk² of Arm. Lb. Ft.² B C For blower ventilated, blower can only be mounted on side of motor, because there’s no air opening at the top of the motor. The motor leads exit at the top of the motor. FC 2F BS 0.28 5.80 15.26 16.51 4.50 6.63 83 186AT 0.45 8.30 16.76 18.01 7.00 8.13 105 L186AT 0.67 8.30 18.76 20.01 7.00 10.13 128 189AT 0.77 11.56 20.76 22.01 10.00 12.13 162 Other L182AT Terms 4.2 Approx. Net Wt. Lbs. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames L182ACY to 189ACY Dripproof Fully Guarded and Totally Enclosed Nonventilated 4.5” Type C-Face Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END 1 9.24 DRIVE END COVER .12 .70 CONDUIT HOLE ACCESSORY MOUNTING FACE 1.44 R5.20 .375-16 THREAD MINIMUM THREAD ENGAGEMENT .50; MAX BOLT PENETRATION .62(4) HOLES, EQUALLY SPACED .14 MAX. 1 2.00 BS .75 NPT FOR CONDUIT 3 KEY .1875 X .1875 X 1.38 LG 6.50 8.94 2 R4.92 .12 4 4.50 4.47 5.88 8.82 MAX. 4.500 4.497 .8750 .8745 45° 4 1.50 (4) HOLES .4062 DIA. 2.00 .38 3.75 2F 7.50 2.25 B MAX 8.90 MAX. .13 2.75 ➀ Splashproof fully guarded machines will have additional covers, increasing the overall width at the commutator end and drive end PG103 side air openings. Mounting face will be square and rabbet diameter concentric with shaft within .004 inch total indicator reading. ➁ Dripproof, fully guarded vertical drive end shaft down machines will have additional covers, increasing the overall width and exceeding bottom of mounting feet at the commutator end openings. The standard single shaft machine has the commutator end bearing bracket and shaft extension prepared to accept accessores. For additional information, see page 4.48. Outline Dimensions Shaft runout not to exceed .002 inch total indicator reading. ➂ Represents minimum length of shaft available for hubs. ➃ Air openings for dripproof fully guarded. Totally enclosed machines will not have openings. Approx. Wk² of Arm. Lb. Ft.² B C 2F AG BS L182ACY 0.28 5.80 15.26 4.50 13.14 6.63 9.51 80 186ACY 0.45 8.30 16.76 7.00 14.64 8.13 11.01 102 L186ACY 0.67 8.30 18.76 7.00 16.64 10.13 13.01 128 189ACY 0.77 11.56 20.76 10.00 18.64 12.13 15.01 162 Approx. Net Wt. Lbs. Terms Other BV Application Information Frame Accessories & Modifications 22.5° 1.44 2.12 BV Modifications Pricing AG 8.88 Motor Pricing C www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.3 Frames L182ATC to 189ATC Dripproof Fully Guarded and Totally Enclosed Nonventilated 8.5” Type C-Face Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction KEY .1875 X .1875 X .88 LONG Motor Pricing COMMUTATOR END FC C 8.88 1 CONDUIT HOLE 1.44 BV ACCESSORY MOUNTING SURFACE 1 1.44 R5.20 9.24 DRIVE END COVER 2.12 .70 22.5° .20 .30 MIN. .75 NPT FOR CONDUIT .500-13 THREAD .75 DP (MAX BOLT PENETRATION .82) (4) HOLES EQUALLY SPACED 3 2.00 BS KEY .25 X .25 X 1.38 LG Modifications Pricing 1.75 1.50 3 8.94 R4.92 .8750 .8745 (4) HOLES .4062 DIA. 2.00 .38 3.75 Accessories & Modifications 1.1250 1.1245 45° 4 1.50 .13 2F 7.50 2.75 2.25 B MAX 8.90 MAX. ➀ Splashproof fully guarded machines will have additional covers,PG104 Mounting face will be square and rabbet diameter concentric with shaft within .004 inch total indicator reading. increasing the overall width at the commutator end and drive end side air openings. Shaft runout not to exceed .002 inch total indicator reading. ➁ Dripproof, fully guarded vertical drive end shaft down machines will have additional covers, increasing the overall width and exceeding bottom of mounting feet at the commutator end openings. ➂ Represents minimum length of shaft available for hubs. ➃ Air openings for dripproof fully guarded. Totally enclosed machines will not have openings. Commutator end shaft extension is furnished only when specifically ordered. The standard single shaft machine has the commutator end bearing bracket and shaft extension prepared to accept accessores. For additional information, see page 4.48. Frame Approx. Wk² of Arm. Lb. Ft.² B C FC 2F BS L182ATC 0.28 5.80 15.26 16.51 4.50 6.63 9.51 80 186ATC 0.45 8.30 16.76 18.01 7.00 8.13 11.01 102 L186ATC 0.67 8.30 18.76 20.01 7.00 10.13 13.01 128 189ATC 0.77 11.56 20.76 22.01 10.00 12.13 15.01 162 BV Approx. Net Wt. Lbs. Terms Other Application Information Outline Dimensions 8.82 MAX. .12 4 4.50 4.47 7.25 8.500 8.497 2 From 36C69710CA 4.4 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames L182ATD to 189ATD Dripproof Fully Guarded and Totally Enclosed Nonventilated Type D-Flange Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END 11.00 MAX. C 1.44 8.88 1.44 1 .70 1 22.5° BV CONDUIT HOLE .5312 (4) HOLES EQ. SP. .23 .75 NPT FOR CONDUIT R5.20 45° 2.25 ACCESSORY MOUNTING FACE KEY .25 X .25 X 1.38 LG .45 BS 2.00 10.00 3 Motor Pricing AG 2 Modifications Pricing 8.94 9.000 8.997 R4.92 .12 4.50 4.47 1.1250 1.1245 1.50 2.00 .38 .4062 (4) HOLES 7.50 2.75 2F 2.37 8.90 MAX. Accessories & Modifications 3.75 B MAX Mounting face will be square and rabbet diameter concentric with shaft within .004 inch total indicator reading. ➁ Dripproof, fully guarded vertical drive end shaft down machines will have additional covers, increasing the overall width and exceeding bottom of mounting feet at the commutator end openings. The standard single shaft machine has the commutator end bearing bracket and shaft extension prepared to accept accessores. For additional information, see page 4.48. Shaft runout not to exceed .002 inch total indicator reading. Outline Dimensions PG105 ➀ Splashproof fully guarded machines will have additional covers, increasing the overall width at the commutator end and drive end side air openings. Frame Approx. Wk² of Arm. Lb. Ft.² B C 2F AG BS L182ATD 0.28 5.80 15.26 4.50 13.01 6.63 9.38 82 186ATD 0.45 8.30 16.76 7.00 14.51 8.13 10.88 104 L186ATD 0.67 8.30 18.76 7.00 16.51 10.13 12.88 130 189ATD 0.77 11.56 20.76 10.00 18.51 12.13 14.88 164 Approx. Net Wt. Lbs. Terms Other BV Application Information ➂ Represents minimum length of shaft available for hubs. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.5 Totally Enclosed Fan Cooled Frames L182AT to 189AT General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction DRIVE END COMMUTATOR END 9.94 DIA. FC 8.88 2.39 .75 NPT FOR CONDUIT 1 2.25 1.50 R5.20 KEY .25 X .25 X 1.38 LG 2.00 KEY .1875 X .1875 .88 LONG 1 .8750 .8745 22.5° .14 1.1250 1.1245 8.94 AIR OUT 4.50 4.47 AIR IN 2.00 2F (4) HOLES .4062 DIA. B MAX Approx. Wk² of Arm. Lb. Ft.² B .38 7.50 8.90 MAX. PG106 Shaft runout shall not exceed .002 inch total indicator reading. For mounting position, see enclosure and mounting assembly. Frame 1.50 3.75 2.75 ➀ Represents minimum length of shaft available for hubs. Outline Dimensions Accessories & Modifications CONDUIT HOLE BS .20 Modifications Pricing Motor Pricing C 1.75 Commutator end shaft extension is furnished only when specifically ordered. C FC 2F BS Approx. Net Wt. Lbs. 0.28 5.80 17.45 19.47 4.50 6.63 83 0.45 8.30 18.95 20.97 7.00 8.13 105 L186AT 0.67 8.30 20.95 22.97 7.00 10.13 128 189AT 0.77 11.56 22.95 24.97 10.00 12.13 165 Terms Other Application Information 182AT 186AT From 36C697101BA 4.6 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames L182ACY to 189ACY Totally Enclosed Fan Cooled 4.5” Type C-Face Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END 2.12 8.88 BV .12 22.5° .375-16 THREAD MINIMUM THREAD ENGAGEMENT .50; MAX BOLT PENETRATION .62(4) HOLES, EQUALLY SPACED .14 MAX. CONDUIT HOLE R5.20 .75 NPT FOR CONDUIT 2.00 BS 1 KEY .1875 X .1875 X 1.38 LG AIR IN 45° 6.50 4.500 4.497 .12 AIR OUT .8750 .8745 2.00 1.50 .38 3.75 (4) HOLES .4062 DIA. 2F 7.50 .13 2.75 B MAX 8.90 MAX. 5.88 2.25 Accessories & Modifications 4.50 4.47 8.82 MAX. Modifications Pricing 8.94 PG107 ➀ Represents minimum length of shaft available for hubs. For mounting position, see enclosure and mounting assembly. Motor Pricing C AG 9.94 Mounting face will be square and rabbet diameter concentric with shaft within .004 inch total indicator reading. Frame Approx. Wk² of Arm. Lb. Ft.² B C 2F AG BS L182ACY 0.28 5.80 17.45 4.50 15.33 6.63 9.51 83 L186ACY 0.45 8.30 18.95 7.00 16.83 8.13 11.01 105 L186ACY 0.67 8.30 20.95 7.00 18.83 10.13 13.01 133 189ACY 0.77 11.56 22.95 10.00 20.83 12.13 15.01 165 Approx. Net Wt. Lbs. Terms Other Application Information BV Outline Dimensions Shaft runout shall not exceed .002 inch total indicator reading. From 36B467421TA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.7 Totally Enclosed Fan Cooled Frames L182ATC to 189ATC 8.5” Type C-Face Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction FC COMMUTATOR END Motor Pricing .30 MIN. CONDUIT HOLE 8.88 BS AIR IN R5.20 .500-13 THD. - .75 DEEP (MAX. BOLT PENETRATION .82) (4) HOLES EQ. SP. 2.00 .75 NPT FOR CONDUIT .20 1 KEY .25 X .25 X 1.38 LG 1.75 1 1.50 1.50 2.00 (4) HOLES .4062 DIA. 45° .13 2F 7.50 2.75 2.25 B MAX ➀ Represents minimum length of shaft available for hubs. PG108 For mounting position, see enclosure and mounting assembly. Mounting face will be square and rabbet diameter concentric with shaft within .004 inch total indicator reading. Shaft runout shall not exceed .002 inch total indicator reading. Commutator end shaft extension is furnished only when specifically ordered. Frame Approx. Wk² of Arm. Lb. Ft.² B C FC 2F AG BS L182ATC 0.28 5.80 17.45 19.47 4.50 15.33 6.63 9.51 83 186ATC 0.45 8.30 18.95 20.97 7.00 16.83 8.13 11.01 105 L186ATC 0.67 8.30 20.95 22.97 7.00 18.83 10.13 13.01 133 189ATC 0.77 11.56 22.95 24.97 10.00 20.83 12.13 15.01 165 BV Terms Other Application Information Outline Dimensions 7.25 8.82 MAX. 1.1250 1.1245 KEY .1875 X .1875 X .88 LG. .38 3.75 8.500 8.497 .12 AIR OUT .8750 .8745 4.50 4.47 8.90 MAX. Accessories & Modifications 2.12 BV 22.5° 8.94 Modifications Pricing C AG 9.94 4.8 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Approx. Net Wt. Lbs. Frames L182ATD to 189ATD Totally Enclosed Fan Cooled Type D-Flange Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END C AG R5.20 AIR IN Ø11.00 MAX. 2.12 KEY .25 X .25 X 1.38 LG .23 .45 2.00 BS 8.94 45° Ø 4.50 4.47 AIR OUT .28 Ø 2.00 3.75 1.50 7.50 8.90 MAX. 9.000 8.997 1.1250 1.1245 Ø10.00 .12 2F Modifications Pricing BV .13 Ø.5312 (4) HOLES EQUAL SPACED 2.25 (4) HOLES .4062 DIA. Accessories & Modifications 22.5° 2.74 B MAX Mounting face will be square and rabbet diameter concentric with shaft within .004 inch total indicator reading. ➀ Represents minimum length of shaft available for hubs. For mounting position, see enclosure and mounting assembly. Outline Dimensions Ø9.94 Motor Pricing .75 NPT CONDUIT Shaft runout shall not exceed .002 inch total indicator reading. Approx. Wk² of Arm. Lb. Ft.² B L182ATD 0.28 5.80 186ATD 0.45 8.30 Frames L182ATD to 189ATD 18.95 7.00 L186ATD 0.67 189ATD 0.77 C AG BS 4.50 15.20 6.63 9.38 85 16.70 8.13 10.88 107 8.30 20.95 7.00 18.70 Type D-Flange Mounting w/feet 10.13 12.88 133 11.56 22.95 12.13 14.88 167 PAGE 4.9 17.45 20.70 Terms Other 10.00 BV Approx. Net Wt. Lbs. 2F Application Information Frame From 36B467521FA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.9 Frames 218AT to 329AT Dripproof Fully Guarded*, Splashproof and Totally Enclosed Nonventilated General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction ZA Modifications Pricing Accessories & Modifications Outline Dimensions Application Information Other ZA AB AC N ACCESSORY MOUNTING FACE N-W FN XN FV V 0.20" U U XL AIR INLET BS Terms P C .70 Motor Pricing FC COMMUTATOR END O AF D AIR OUTLET FN-FW FW AIR INLET 2F AIR OUTLET HOLE FOR AA CONDUIT W K APPROX 2E H - HOLE BA A B Frame 218AT 219AT 2110AT 258AT 259AT 287AT 288AT 327AT 328AT 329AT Frame 210 250 280 320 Approx. Net Wt. In Lb. 234 252 280 361 403 493 548 691 769 888 AB 9.620 10.62 11.34 Approx. WK2 of Arm Lb. Ft.2 1.350 1.490 1.710 2.910 3.310 4.670 5.360 8.450 9.670 11.40 AC 7.56 8.56 9.28 Drive End Key Width 0.3125 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 0.5000 0.5000 Thick 0.3125 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 0.5000 0.5000 AA=1.25 AF 3.62 3.62 3.62 Not Available XL 5.94 5.94 5.94 G J E Commutator End Key Lgth. ±.03 1.75 1.75 1.75 2.25 2.25 2.50 2.50 3.00 3.00 3.00 Width 0.2500 0.2500 0.2500 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 XN 4.38 4.38 4.38 AB 11.48 11.74 12.46 13.44 DIMENSIONS IN INCHES pg110A Max. Lgth. ±.03 1.00 1.00 1.00 1.50 1.50 2.00 2.00 2.25 2.25 2.25 Thick 0.2500 0.2500 0.2500 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 10.40 10.40 10.40 12.40 12.40 13.88 13.88 15.88 15.88 15.88 B Max. 11.56 12.56 14.06 14.06 15.56 14.16 15.66 15.96 17.96 19.96 DIMENSIONS IN INCHES AA=2.00 AC AF XL 8.920 4.62 7.38 9.180 4.62 7.38 9.900 4.62 7.38 10.88 4.62 7.38 ‡ D 5.25 5.25 5.25 6.25 6.25 7.00 7.00 8.00 8.00 8.00 C 24.22 25.22 26.72 27.14 28.76 30.98 32.72 33.44 35.32 37.94 XN 5.38 5.38 5.38 5.38 E 4.25 4.25 4.25 5.00 5.00 5.50 5.50 6.25 6.25 6.25 2F 10.0 11.0 12.5 12.5 14.0 12.5 14.0 14.0 16.0 18.0 AB AC 14.90 15.12 11.28 11.50 G 0.50 0.50 0.50 0.62 0.62 0.64 0.64 0.50 0.75 0.75 H 0.4062 0.4062 0.4062 0.5312 0.5312 0.5312 0.5312 0.6562 0.6562 0.6562 AA=3.00 AF Not Available Not Available 6.62 6.62 J 2.00 2.00 2.00 2.25 2.25 2.50 2.50 3.00 3.00 3.00 K 2.20 2.20 2.20 2.00 2.00 2.00 2.00 2.30 2.30 2.30 XL XN 10.50 10.50 8.56 8.56 DIMENSIONS IN INCHES Frame 218AT 219AT 2110AT 258AT 259AT 287AT 288AT 327AT 328AT 329AT N 2.91 2.91 2.91 3.41 3.41 3.91 3.91 4.41 4.41 4.41 O 10.46 10.46 10.46 12.46 12.46 13.94 13.94 15.94 15.94 15.94 P 10.42 10.42 10.42 12.42 12.42 13.88 13.88 15.88 15.88 15.88 U 1.375 1.375 1.375 1.625 1.625 1.875 1.875 2.125 2.125 2.125 ∆ V 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.0 4.0 4.0 W 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 N-W 2.75 2.75 2.75 3.25 3.25 3.75 3.75 4.25 4.25 4.25 * Dripproof, fully guarded machines can be used for wall or ceiling mounting. Assembly modifications must be made to maintain proper enclosure. ‡ Dimensions “D” will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension “D” is 8 inches or less. When dimension “D” is over 8 inches, shims up to .06 inch may be necessary. Splashproof machines will have additional covers, increasing the overall width at the commutator end and drive end side cover openings. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. BA 3.50 3.50 3.50 4.25 4.25 4.75 4.75 5.25 5.25 5.25 FC 25.97 26.97 28.47 29.39 31.01 33.75 35.47 36.69 38.57 41.19 FN 2.45 2.45 2.45 2.95 2.95 3.45 3.45 3.95 3.95 3.95 FU 1.125 1.125 1.125 1.375 1.375 1.625 1.625 1.875 1.875 1.875 ∆ FV 2.0 2.0 2.0 2.5 2.5 3.0 3.0 3.5 3.5 3.5 FW 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 FN-FW 2.25 2.25 2.25 2.75 2.75 3.25 3.25 3.75 3.75 3.75 BS 8.360 9.360 10.87 9.650 11.26 10.89 12.62 11.80 13.68 16.30 XZ 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 For shipping weight add 15% to net weight. 10 Refer to GE Energy for dimensions. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. The standard single shaft machine has the commutator end bearing bracket and shaft prepared to accept additional information, see page 4.48. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. From 36C697102AA 4.10 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 218ATC to 329ATC Dripproof Fully Guarded*, Splashproof and Totally Enclosed Nonventilated Type C-Face Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction FC BF TAP (4) HOLES EQUALLY SPACED C ZA P AC BB MIN. FV XN V .20 AK FU AF AIR OUTLET BC HOLE FOR AA CONDUIT BA 2F Thick 0.3125 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 0.5000 0.5000 Commutator End Key Lgth. ±.03 1.75 1.75 1.75 2.25 2.25 2.50 2.50 3.00 3.00 3.00 Width 0.2500 0.2500 0.2500 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 Thick 0.2500 0.2500 0.2500 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 BF Frame 218ATC 219ATC 2110ATC 258ATC 259ATC 287ATC 288ATC 327ATC 328ATC 329ATC Frame 210 250 280 320 BA 3.5 3.5 3.5 4.25 4.25 4.75 4.75 5.25 5.25 5.25 AB 9.620 10.62 11.34 BB Min. 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 FN 2.45 2.45 2.45 2.95 2.95 3.45 3.45 3.95 3.95 3.95 AC 7.56 8.56 9.28 FU 1.125 1.125 1.125 1.375 1.375 1.625 1.625 1.875 1.875 1.875 AA=1.25 AF 3.62 3.62 3.62 Not Available BC 0.25 0.25 0.25 0.24 0.24 0.24 0.24 0.24 0.24 0.24 XL 5.94 5.94 5.94 Tap .500-13 .500-13 .500-13 .500-13 .500-13 .500-13 .500-13 .625-11 .625-11 .625-11 XN 4.38 4.38 4.38 DIMENSIONS IN INCHES Lgth. ±.03 A Max. 1.00 10.40 1.00 10.40 1.00 10.40 1.50 12.40 1.50 12.40 2.00 13.88 2.00 13.88 2.25 15.88 2.25 15.88 2.25 15.88 B Max. 11.56 12.56 14.06 14.06 15.56 14.16 15.66 15.96 17.96 19.96 • 800-541-7191 5.25 5.25 5.25 6.25 6.25 7.00 7.00 8.00 8.00 8.00 DIMENSIONS IN INCHES ∆ Depth FV FW FN-FW 1.00 2.0 0.2 2.25 1.00 2.0 0.2 2.25 1.00 2.0 0.2 2.75 1.00 2.5 0.2 2.75 1.00 2.5 0.2 2.75 1.00 3.0 0.2 3.25 1.00 3.0 0.2 3.25 1.25 3.5 0.2 3.75 1.25 3.5 0.2 3.75 1.25 3.5 0.2 3.75 AB 11.48 11.74 12.46 13.44 E 4.25 4.25 4.25 5.00 5.00 5.50 5.50 6.25 6.25 6.25 2F 10.0 11.0 12.5 12.5 14.0 12.5 14.0 14.0 16.0 18.0 AH 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.0 4.0 4.0 DIMENSIONS IN INCHES AA=2.0 AC AF XL 8.920 4.62 7.38 9.180 4.62 7.38 9.900 4.62 7.38 10.88 4.62 7.38 * Dripproof, fully guarded machines can be used for wall or ceiling mounting Assembly modifications must be made to maintain proper enclosure. ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. Splashproof machines will have additional covers, increasing the overall width at the commutator end and drive end side cover openings. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. www.gemotors.com ‡ PG111 D C 24.22 25.22 26.72 27.14 28.76 30.98 32.72 33.44 35.32 37.94 G 0.50 0.50 0.50 0.62 0.62 0.64 0.64 0.75 0.75 0.75 H 0.4062 0.4062 0.4062 0.5312 0.5312 0.5312 0.5312 0.6562 0.6562 0.6562 AJ 7.250 7.250 7.250 7.250 7.250 9.000 9.000 11.00 11.00 11.00 XN 5.38 5.38 5.38 5.38 J 2.0 2.0 2.0 2.3 2.3 2.5 2.5 3.0 3.0 3.0 AK 8.50 8.50 8.50 8.50 8.50 10.5 10.5 12.5 12.5 12.5 K 2.2 2.2 2.2 2.0 2.0 2.0 2.0 2.3 2.3 2.3 N 2.97 2.97 2.70 3.47 3.47 3.97 3.97 4.47 4.47 4.47 ZA 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 O 10.46 10.46 10.46 12.46 12.46 13.94 13.94 15.94 15.94 15.94 P 10.42 10.42 10.42 12.42 12.42 13.88 13.88 15.88 15.88 15.88 Max 9.000 9.000 9.000 10.00 10.00 11.25 11.25 14.00 14.00 14.00 AB AC 14.90 15.12 11.28 11.50 ∆ V 2.5 2.5 1.5 3.0 3.0 3.5 3.5 4.0 4.0 4.0 U 1.375 1.375 1.375 1.625 1.625 1.875 1.875 2.125 2.125 2.125 BV 12.11 13.11 14.62 14.14 15.75 15.88 17.61 17.29 19.17 21.79 AA=3.0 AF Not Available Not Available 6.62 6.62 BS 8.360 9.360 10.87 9.650 11.26 10.87 12.62 11.80 13.68 13.68 W 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 N-W 2.75 2.75 2.75 3.25 3.25 3.75 3.75 4.25 4.25 4.25 FC 25.97 26.97 28.47 29.39 31.01 33.73 35.47 36.69 38.57 41.19 XL XN 10.5 10.5 8.56 8.56 For shipping weight add 15% to net weight. 10 Refer to GE Energy for dimensions. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. For frames CD218ATC thru CD288ATC inclusive, mounting face will be square and rabbet diameter concentric with shaft within 0.004 inch total indicator reading. "AK" dimension: +0.000 inch -0.005 inch. For frames CD327ATC thru CD328ATC inclusive, mounting face will be square and rabbet diameter concentric with shaft within 0.004 inch total indicator reading. "AK" dimensions: +0.000 inch -0.005 inch. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. From 36C697102CA GEP387M 09/11 • Prices and data subject to change without notice. 4.11 Accessories & Modifications Width 0.3125 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 0.5000 0.5000 A Outline Dimensions Frame 218ATC 219ATC 2110ATC 258ATC 259ATC 287ATC 288ATC 327ATC 328ATC 329ATC Drive End Key G J 2E N B Approx. Approx. Net Wt. WK2 of Arm Lb. Ft.2 In Lb. 243 1.35 261 1.49 289 1.71 378 2.91 420 3.31 522 4.67 577 5.36 720 8.45 798 9.67 917 11.4 E H - HOLE N-W Application Information FN-FW D Modifications Pricing AIR OUTLET K APPROX AIR INLET O XL W BS FW AJ BD MAX. U Motor Pricing AB Other FN ZA AH BV .70 ACCESSORY MOUNTING FACE Terms COMMUTATOR END Frames 218ATD to 329ATD Dripproof Fully Guarded*, Splashproof and Totally Enclosed Nonventilated Type D-Flange Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END FC C AB AG Motor Pricing .70 ZA P 45° BF HOLE (4) HOLES EQUALLY SPACED FV N .20 Modifications Pricing Accessories & Modifications Outline Dimensions Application Information Other ZA BB MAX. XN V U AIR OUTLET FU Terms BD BE ACCESSORY MOUNTING FACE FN AC AH BV AK BA 2F G J AIR INLET (APPROX) K H DIA. (4) HOLES D HOLE FOR AA CONDUIT FW AIR INLET O AF W BS FN-FW AJ XL E 2E B A Frame 218ATD 219ATD 2110ATD 258ATD 259ATD 287ATD 288ATD 327ATD 328ATD 329ATD Approx. Approx. Net Wt. WK2 of Arm Lb. Ft.2 In Lb. 264 1.35 282 1.49 310 1.71 416 2.91 458 3.31 551 4.67 606 5.36 745 8.45 823 9.67 942 11.4 Drive End Key Width 0.3125 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 0.5000 0.5000 Thick 0.3125 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 0.5000 0.5000 Commutator End Key Lgth. ±.03 1.75 1.75 1.75 2.25 2.25 2.50 2.50 3.00 3.00 3.00 Width 0.250 0.250 0.250 0.313 0.313 0.375 0.375 0.500 0.500 0.500 Thick 0.2500 0.2500 0.2500 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 0.5000 DIMENSIONS IN INCHES pg112 Lgth. ±.03 A Max. 1.00 10.40 1.00 10.40 1.00 10.40 1.50 12.40 1.50 12.40 2.00 13.88 2.00 13.88 2.25 15.88 2.25 15.88 2.25 15.88 B Max. 11.56 12.56 14.06 14.06 15.56 14.16 15.66 15.96 17.96 19.96 C 24.22 25.22 26.72 27.14 28.76 30.98 32.72 33.44 35.32 37.94 ‡ D 5.25 5.25 5.25 6.25 6.25 7.00 7.00 8.00 8.00 8.00 E 4.25 4.25 4.25 5.00 5.00 5.50 5.50 6.25 6.25 6.25 2F 10.0 11.0 12.5 12.5 14.0 12.5 14.0 14.0 16.0 18.0 G 0.50 0.50 0.50 0.62 0.62 0.64 0.64 0.75 0.75 0.75 H 0.4062 0.4062 0.4062 0.5312 0.5312 0.5312 0.5312 0.6562 0.6562 0.6562 J 2.00 2.00 2.00 2.25 2.25 2.50 2.50 3.00 3.00 3.00 K 2.2 2.2 2.2 2.0 2.0 2.0 2.0 2.3 2.3 2.3 N 2.97 2.97 2.97 3.47 3.47 3.97 3.97 4.47 4.47 4.47 O 10.46 10.46 10.46 12.46 12.46 13.94 13.94 15.94 15.94 15.94 P 10.42 10.42 10.42 12.42 12.42 13.88 13.88 15.88 15.88 15.88 U 1.375 1.375 1.375 1.625 1.625 1.875 1.875 2.125 2.125 2.125 V 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.0 4.0 4.0 W 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 BA 3.50 3.50 3.50 4.25 4.25 4.75 4.75 5.75 5.75 5.75 DIMENSIONS IN INCHES Frame 218ATD 219ATD 2110ATD 258ATD 259ATD 287ATD 288ATD 327ATD 328ATD 329ATD Frame 210 250 280 320 BB Max 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 AB 9.620 10.62 11.34 BD 14 14 14 18 18 18 18 18 18 18 BE 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 AC 7.56 8.56 9.28 BF 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 AA=1.25 AF 3.62 3.62 3.62 Not Available BV 11.86 12.86 14.86 13.89 15.50 15.63 17.37 17.04 18.92 21.54 XL 5.94 5.94 5.94 FC 25.97 26.97 28.47 29.39 31.01 33.73 35.47 36.69 38.57 41.19 XN 4.38 4.38 4.38 FN 2.45 2.45 2.45 2.95 2.95 3.45 3.45 3.95 3.95 3.95 AB 11.48 11.74 12.46 13.44 ∆ FU 1.125 1.125 1.125 1.375 1.375 1.625 1.625 1.875 1.875 1.875 www.gemotors.com • 800-541-7191 FW 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 DIMENSIONS IN INCHES AA=2.0 AC AF XL 8.920 4.62 7.38 9.180 4.62 7.38 9.900 4.62 7.38 10.88 4.62 7.38 * Dripproof, fully guarded machines can be used for wall or ceiling mounting Assembly modifications must be made to maintain proper enclosure. ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. Splashproof machines will have additional covers, increasing the overall width at the commutator end and drive end side cover openings. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. 4.12 FV 2.0 2.0 2.0 2.5 2.5 3.0 3.0 3.5 3.5 3.5 FN-FW 2.25 2.25 2.25 2.75 2.75 3.25 3.25 3.75 3.75 3.75 XN 5.38 5.38 5.38 5.38 AG 21.47 22.47 23.97 23.89 25.51 27.23 28.97 29.19 31.07 33.69 AH 2.75 2.75 2.75 3.25 3.25 3.75 3.75 4.25 4.25 4.25 AJ 12.5 12.5 12.5 16.0 16.0 16.0 16.0 16.0 16.0 16.0 AB AC 14.90 15.12 11.28 11.50 AK 11 11 11 14 14 14 14 14 14 14 AA=3.0 AF Not Available Not Available 6.62 6.62 BS 8.360 9.360 10.86 9.640 11.26 10.83 12.62 11.80 13.68 16.30 ZA 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 XL XN 10.5 10.5 8.56 8.56 For shipping weight add 15% to net weight. 10 Refer to GE Energy for dimensions. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. For frames CD218ATC thru CD288ATC inclusive, mounting face will be square and rabbet diameter concentric with shaft within 0.004 inch total indicator reading. "AK" dimension: +0.000 inch -0.005 inch. For frames CD327ATC thru CD328ATC inclusive, mounting face will be square and rabbet diameter concentric with shaft within 0.004 inch total indicator reading. "AK" dimensions: +0.000 inch -0.005 inch. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. From 36C697102DA GEP387M 09/11 • Prices and data subject to change without notice. Frames 218AT to 2110AT Totally Enclosed Fan Cooled General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction 11.70 DIA. 10.41 FC C 2.45 .20 - 2.25 KEY .25 X .25 X 1.00 LONG 2.00 KEY .3125 X .3125 X 1.75 LONG AC 2.91 AIR OUT .15 2.75 XN 1 AB Motor Pricing COMMUTATOR END 2.50 1 BS 1.1250 1.1245 5.25 5.22 1.3750 1.3745 Modifications Pricing 11.25 AF AIR IN 2.20 APPROX. 3 HOLE FOR AA CONDUIT 3.50 2F 4.25 .50 2.00 .4062 DIA. (4) HOLES B MAX. 8.50 10.40 MAX. Accessories & Modifications 5 pg113 B 11.56 12.56 14.06 C 26.82 27.82 29.32 FC 29.34 30.34 31.84 2F 10.0 11.0 12.5 BS 8.360 9.360 10.87 Approx. Net Wt. 241 259 287 AB 9.620 11.48 AC 7.56 8.92 AF 3.62 4.62 XL 5.94 7.38 XN 4.38 5.38 ➃ Shaft runout shall not exceed 0.002 inch total indicator reading on drive end. ➄ Shroud is removable to permit access to hand hole covers. ➅ Commutator end shaft extension is furnished only when specifically ordered. For shipping weight, add 15% to net weight. Terms Other Application Information ➀ Represents minimum length of shaft available for hubs. ➁ Machine can be used for wall or ceiling mounting. ➂ Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. Conduit Box Dimensions AA 1.25 2 Outline Dimensions Frame 218AT 219AT 2110AY From 36C697102EA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.13 Frames 258AT to 328AT Totally Enclosed Fan Cooled General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END DRIVE END FC C Motor Pricing P FN XP .06 AB .93 AC ACCESSORY MOUNTING FACE AIR OUTLET N N-W XN V FV O XL FU Modifications Pricing AF .20 D HOLE FOR AA CONDUIT G U AIR INLET BS E E W FW J K (APPROX) FN-FW H HOLE BA 2F B MAX. A MAX. Frame 258AT 259AT 287AT 288AT 327AT 328AT Approx. Net Wt. In Lb. 397 442 532 587 732 812 Approx. WK2 of Arm Lb. Ft.2 3.170 3.570 5.090 5.780 9.200 10.42 Width 0.375 0.375 0.500 0.500 0.500 0.500 Thick 0.375 0.375 0.500 0.500 0.500 0.500 Commutator End Key Lgth. ±.03 2.25 2.25 2.50 2.50 3.00 3.00 Width 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 DIMENSIONS IN INCHES Lgth. ±.03 1.50 1.50 2.00 2.00 2.25 2.25 Thick 0.3125 0.3125 0.3750 0.3750 0.5000 0.5000 A Max. 12.40 12.40 13.88 13.88 15.88 15.88 B Max. 14.06 15.56 14.16 15.66 15.96 17.96 ‡ D 6.25 6.25 7.00 7.00 8.00 8.00 C 30.32 31.94 34.66 36.40 37.62 39.50 E 5.00 5.00 5.50 5.50 6.25 6.25 2F 12.5 14.0 12.5 14.0 14.0 16.0 G 0.62 0.62 0.64 0.64 0.75 0.75 H 0.5312 0.5312 0.5312 0.5312 0.6562 0.6562 J 2.25 2.25 2.50 2.50 3.00 3.00 K 2.0 2.0 2.0 2.0 2.3 2.3 DIMENSIONS IN INCHES Frame 258AT 259AT 287AT 288AT 327AT 328AT Frame 210 250 280 320 N 3.41 3.41 3.91 3.91 4.41 4.41 AB 9.620 10.62 11.34 O 12.75 12.75 14.25 14.25 16.25 16.25 AC 7.56 8.56 9.28 P 13.00 13.00 14.52 14.52 16.52 16.52 ∆ V 3.0 3.0 3.5 3.5 4.0 4.0 U 1.625 1.625 1.875 1.875 2.125 2.125 AA=1.25 AF 3.62 3.62 3.62 Not Available XL 5.94 5.94 5.94 XN 4.38 4.38 4.38 W 0.16 0.16 0.16 0.16 0.16 0.16 AB 11.48 11.74 12.46 13.44 N-W 3.25 3.25 3.75 3.75 4.25 4.25 BA 4.25 4.25 4.75 4.75 5.25 5.25 FC 32.64 34.26 37.48 39.22 40.94 42.82 DIMENSIONS IN INCHES AA=2.0 AC AF XL 8.920 4.62 7.38 9.180 4.62 7.38 9.900 4.62 7.38 10.88 4.62 7.38 ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. FN 3.25 3.25 3.75 3.75 4.25 4.25 ∆ FV 2.5 2.5 3.0 3.0 3.5 3.5 FU 1.375 1.375 1.625 1.625 1.875 1.875 XN 5.38 5.38 5.38 5.38 FW 0.5 0.5 0.5 0.5 0.5 0.5 AB AC 14.90 15.12 11.28 11.50 FN-FW 2.75 2.75 3.25 3.25 3.75 3.75 AA=3.0 AF Not Available Not Available 6.62 6.62 BS 9.650 11.26 10.89 12.62 11.80 13.68 XP 12.42 12.42 13.88 13.88 15.88 15.88 XL XN 10.5 10.5 8.56 8.56 For shipping weight add 15% to net weight. 10 Refer to GE Energy for dimensions. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. When commutator end shaft is not furnished, shaft and fan shroud on commutator end is prepared for shaft driven accessories. Refer to 36C697103BA for dimensions. Terms Other Application Information Outline Dimensions Accessories & Modifications pg114 Drive End Key From 36C697102BA 4.14 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 365AT TO 5010AY Dripproof Fully Guarded*, Splashproof and Totally Enclosed Nonventilated General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END XZ FC ACCESSORY MOUNTING FACE AB AC Motor Pricing N XN N-W V V XL AE K (APPROX) FN 2F AIR INLET Frame 365AT 366AT 368AT 407AT L407AT 409AT L409AT 504AT L504AT 506AT L506AT 508AT L508AT 5010AY Approx. Net Wt. In Lb. 750.0 860.0 1020 1300 1350 1600 1650 1900 2070 2290 2440 2810 2970 4260 Approx. WK2 of Arm Lb. Ft.2 15.610 18.270 22.210 35.470 35.540 43.810 43.880 79.100 79.150 98.760 98.810 121.87 122.92 157.28 HOLE(S) FOR AA CONDUIT AIR OUTLET BA B MAX. G J H HOLE Modifications Pricing BS FW D AIR OUTLET W AD AIR INLET E 2E A PG115 Drive End Key Width 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 1.000 Thick 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 1.000 Commutator End Key Lgth. ±.03 3.50 3.50 3.50 4.00 4.00 4.00 4.00 5.25 5.25 5.25 5.25 5.25 5.25 6.50 Width 0.500 0.500 0.500 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 0.750 Lgth. ±.03 3.00 3.00 3.00 3.50 3.50 3.50 3.50 4.50 4.50 4.50 4.50 4.50 4.50 5.25 Thick 0.500 0.500 0.500 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 0.750 DIMENSIONS IN INCHES A Max. B Max. 17.920 14.16 17.920 15.90 17.920 19.90 20.000 20.16 20.000 20.16 20.000 24.16 20.000 24.16 24.920 18.96 24.920 18.96 24.920 22.96 24.920 22.96 24.920 27.96 24.920 27.96 24.920 34.86 C 33.70 35.90 38.90 40.12 43.52 44.62 48.02 45.74 47.50 49.74 51.50 54.74 56.50 65.49 ‡ D 9.00 9.00 9.00 10.0 10.0 10.0 10.0 12.5 12.5 12.5 12.5 12.5 12.5 12.5 E 7.0 7.0 7.0 8.0 8.0 8.0 8.0 10 10 10 10 10 10 10 2F 12.25 14.00 18.00 18.00 18.00 22.00 22.00 16.00 16.00 20.00 20.00 25.00 25.00 32.00 G 0.74 0.74 0.74 0.86 0.86 0.86 0.86 1.11 1.11 1.11 1.11 1.11 1.11 1.11 H 0.8125 0.8125 0.8125 0.9375 0.9375 0.9375 0.9375 1.1875 1.1875 1.1875 1.1875 1.1875 1.1875 1.1875 J 3.26 3.26 3.26 4.00 4.00 4.00 4.00 4.50 4.50 4.50 4.50 4.50 4.50 4.50 K 2.31 2.31 2.31 2.38 2.38 2.38 2.38 3.00 3.00 3.00 3.00 3.00 3.00 3.00 N 4.92 4.92 4.92 5.42 5.42 5.42 5.42 6.67 6.67 6.67 6.67 6.67 6.67 8.42 DIMENSIONS IN INCHES Frame 365AT 366AT 368AT 407AT L407AT 409AT L409AT 504AT L504AT 506AT L506AT 508AT L508AT 5010AY O 17.91 17.91 17.91 20.15 20.15 20.15 20.15 25.15 25.15 25.15 25.15 25.15 25.15 25.17 P 17.90 17.90 17.90 20.38 20.38 20.38 20.38 25.38 25.38 25.38 25.38 25.38 25.38 25.38 U 2.375 2.375 2.375 2.625 2.625 2.625 2.625 3.250 3.250 3.250 3.250 3.250 3.250 4.125 ∆ V 4.50 4.50 4.50 5.00 5.00 5.00 5.00 6.25 6.25 6.25 6.25 6.25 6.25 8.00 W 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 N-W 4.75 4.75 4.75 5.25 5.25 5.25 5.25 6.50 6.50 6.50 6.50 6.50 6.50 8.25 BA 5.875 5.875 5.875 6.625 6.625 6.625 6.625 8.500 8.500 8.500 8.500 8.500 8.500 8.500 FC 37.45 39.65 42.65 44.37 47.77 48.87 52.27 50.99 52.75 54.99 56.75 59.99 61.75 71.49 FN 4.45 4.45 4.45 4.95 4.95 4.95 4.95 5.95 5.95 5.95 5.95 5.95 5.95 6.70 * Dripproof, fully guarded machines can be used for wall or ceiling mounting Assembly modifications must be made to maintain proper enclosure. ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. Splashproof machines will have additional covers, increasing the overall width at the commutator end and drive end side cover openings. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. FU 2.125 2.125 2.125 2.375 2.375 2.375 2.375 2.875 2.875 2.875 2.875 2.875 2.875 3.25 ∆ FV 4.00 4.00 4.00 4.50 4.50 4.50 4.50 5.50 5.50 5.50 5.50 5.50 5.50 6.25 FW 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 FN-FW 4.25 4.25 4.25 4.75 4.75 4.75 4.75 5.75 5.75 5.75 5.75 5.75 5.75 6.25 AA=3" 9.020 11.22 14.22 15.18 15.18 19.68 19.68 - BS AA=4" 9.02 11.22 14.22 15.18 15.18 19.68 19.68 13.26 17.26 22.26 31.26 AA=(2) 4" AA=Blank 6.640 8.840 11.84 12.80 12.80 12.80 12.80 17.30 17.30 17.30 17.30 10.88 10.88 11.16 14.88 14.88 15.16 19.88 19.88 20.16 28.88 28.88 XZ 0.25 0.25 0.25 - For shipping weight add 15% to net weight. 10 Refer to GE Energy for dimensions. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. The standard single shaft machine has the commutator end bearing bracket and shaft prepared to accept acessories. For additional information, see page 4.48. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. From 36C697106AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.15 Accessories & Modifications AD Outline Dimensions FU O U Application Information AF Other FN-FW XZ Terms .70 P C Frames 365ATD TO L508ATD Dripproof Fully Guarded*, Splashproof and Totally Enclosed Nonventilated Type D-Flange Mounting with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END FC AB Motor Pricing C AG .70 ACCESSORY MOUNTING FACE FN-FW BF DIA (8) HOLES EQUALLY SPACED AC AH BV BD BB XN P XZ BE XZ 45° FV V Modifications Pricing XL AJ U AF FU Accessories & Modifications Outline Dimensions Application Information AE W AD N AD D FW K (APPROX) FN Frame 365ATD 366ATD 368ATD 407ATD L407ATD 409ATD L409ATD 504ATD L504ATD 506ATD L506ATD 508ATD L508ATD Approx. WK2 of Arm Lb. Ft.2 15.610 18.270 22.210 35.470 35.540 43.810 43.880 79.100 79.150 98.760 98.810 121.87 122.92 Thick 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 Commutator End Key Lgth. ±.03 3.50 3.50 3.50 4.00 4.00 4.00 4.00 5.25 5.25 5.25 5.25 5.25 5.25 H DIA (4) HOLES 2E A AIR OUTLET Drive End Key Width 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 J G E AIR OUTLET BA B Approx. Net Wt. In Lb. 820.0 930.0 1090 1380 1430 1680 1730 2000 2170 2390 2540 2910 3070 HOLE(S) FOR AA CONDUIT BC AIR INLET 2F Width 0.500 0.500 0.500 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 Thick 0.500 0.500 0.500 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 PG116 Lgth. ±.03 3.0 3.0 3.0 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5 4.5 4.5 DIMENSIONS IN INCHES A Max. B Max. 17.92 14.16 17.92 15.90 17.92 19.90 20.00 20.16 20.00 20.16 20.00 24.16 20.00 24.16 24.92 18.96 24.92 18.96 24.92 22.96 24.92 22.96 24.92 27.96 24.92 27.96 C 33.70 35.90 38.9 40.12 43.52 44.62 48.02 45.74 47.50 49.74 51.50 54.75 56.50 ‡ D 9.00 9.00 9.00 10.0 10.0 10.0 10.0 12.5 12.5 12.5 12.5 12.5 12.5 E 7.0 7.0 7.0 8.0 8.0 8.0 8.0 10 10 10 10 10 10 2F 12.25 14.00 18.00 18.00 18.00 22.00 22.00 16.00 16.00 20.00 20.00 25.00 25.00 G 0.74 0.74 0.74 0.86 0.86 0.86 0.86 1.11 1.11 1.11 1.11 1.11 1.11 H 0.8125 0.8125 0.8128 0.9375 0.9375 0.9375 0.9375 1.1875 1.1875 1.1875 1.1875 1.1875 1.1875 J 3.26 3.26 3.26 4.00 4.00 4.00 4.00 4.50 4.50 4.50 4.50 4.50 4.50 K 2.31 2.31 2.31 2.38 2.38 2.38 2.38 3.00 3.00 3.00 3.00 3.00 3.00 N 4.92 4.92 4.92 5.42 5.42 5.42 5.42 6.67 6.67 6.67 6.67 6.67 6.67 O 17.91 17.91 17.91 20.15 20.15 20.15 20.15 25.15 25.15 25.15 25.15 25.15 25.15 AJ 20 20 20 22 22 22 22 30 30 30 30 30 30 AK 18 18 18 18 18 18 18 28 28 28 28 28 28 DIMENSIONS IN INCHES Frame 365ATD 366ATD 368ATD 407ATD L407ATD 409ATD L409ATD 504ATD L504ATD 506ATD L506ATD 508ATD L508ATD P 17.90 17.90 17.90 20.38 20.38 20.38 20.38 25.38 25.38 25.38 25.38 25.38 25.38 U 2.375 2.375 2.375 2.625 2.625 2.625 2.625 3.250 3.250 3.250 3.250 3.250 3.250 ∆ V 4.50 4.50 4.50 5.00 5.00 5.00 5.00 6.25 6.25 6.25 6.25 6.25 6.25 W 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 BA 5.875 5.875 5.875 6.625 6.625 6.625 6.625 8.500 8.500 8.500 8.500 8.500 8.500 BB Max 0.25 0.25 0.25 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 BC 0.38 0.38 0.38 0.38 0.38 0.38 BD Max BE Nom 22 1 22 1 22 1 24 1 24 1 24 1 24 1 32 1 32 1 32 1 32 1 32 1 32 1 BF 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 XZ 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.2 2.2 2.2 2.2 2.2 2.2 FC 37.45 39.65 42.65 44.37 47.77 48.87 52.27 50.99 52.75 54.99 56.75 59.99 61.75 FN 4.45 4.45 4.45 4.95 4.95 4.95 4.95 5.95 5.95 5.95 5.95 5.95 5.95 FU 2.125 2.125 2.125 2.375 2.375 2.375 2.375 2.875 2.875 2.875 2.875 2.875 2.875 ∆ FV 4.0 4.0 4.0 4.5 4.5 4.5 4.5 5.5 5.5 5.5 5.5 5.5 5.5 FW 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 FN-FW 4.25 4.25 4.25 4.75 4.75 4.75 4.75 5.75 5.75 5.75 5.75 5.75 5.75 AG 28.95 31.15 34.15 34.87 38.27 39.37 42.77 38.86 40.62 42.86 44.62 47.86 49.62 AH 4.750 4.750 4.750 5.250 5.250 5.250 5.250 6.875 6.875 6.875 6.875 6.875 6.875 Terms Other O AK From 36C697106DA 4.16 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 365AT TO 5010AY Dripproof Fully Guarded*, Splashproof and Totally Enclosed Nonventilated Conduit Box Dimensions General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction CONDUIT BOX DIMENSIONS BS 9.020 11.22 14.22 15.18 19.68 BV 14.9 17.1 20.1 21.8 26.3 BS 6.640 8.840 11.84 12.80 17.30 BV 12.52 14.72 17.72 19.42 23.92 BS 12.8 17.3 AA=4" BV 19.42 23.92 Frame 504ATD L504ATD 506ATD L506ATD 508ATD L508ATD BS 13.26 17.26 22.26 - AA=(2) 4" BS BV 10.88 19 14.88 23 19.88 28 - BV 21.38 25.38 30.38 - AA= Blank BS BV 10.88 19.00 11.16 19.28 14.88 23.00 15.16 23.28 19.88 28.00 20.16 28.26 DIMENSIONS IN INCHES Frame 360AT 400AT 500AT L500AT 5010AY AB 16.08 17.47 AC 12.33 13.72 AA=3" AE AF 9.000 6.44 12.95 6.44 XL 10.12 10.12 XN 7 7 AB 17.82 19.22 21.70 AC 13.20 14.60 17.08 21.94 17.32 Not Available AA=4" AE AF 9.00 8.5 12.95 8.5 16.10 8.5 Not Available 16.10 8.5 XL 13.5 13.5 13.5 XN 8.62 8.62 8.62 AB 18.72 20.12 22.60 AC 14.97 16.37 18.85 13.5 8.62 22.84 19.09 10 XL 13.5 13.5 13.5 XN 13.5 13.5 13.5 13.5 13.5 AA= Blank 13.38" X 13.31" Available Drill Space AE AF XL Not Available 24.76 12.95 6.75 13.5 27.18 16.10 6.75 13.5 27.18 15.70 8.75 13.5 27.42 16.10 6.75 13.5 AB XN 13.5 13.5 13.5 13.5 Refer to GE Energy for dimensions. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. The standard single shaft machine has the commutator end bearing bracket and shaft prepared to accept acessories. For additional information, see page 4.48. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. Mounting face will be square and rabbet diameter concentric with shaft within 0.007 inch total indicator reading. "AK" dimensions: +0.000 inch -0.005 inch. Terms Other Application Information * Dripproof, fully guarded machines can be used for wall or ceiling mounting Assembly modifications must be made to maintain proper enclosure. ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. Splashproof machines will have additional covers, increasing the overall width at the commutator end and drive end side cover openings. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. AA=(2) 4" AE AF 9.000 6.75 12.96 6.75 16.10 6.75 Not Available 3 16.10 6.75 AD 3 3 3 Modifications Pricing BV 14.9 17.1 20.1 21.8 26.3 Accessories & Modifications BS 9.020 11.22 14.22 15.18 19.68 AA= Blank Outline Dimensions Frame 365AT 366AT 368AT 407AT L407AT 409AT L409AT AA=(2) 4" Motor Pricing DIMENSIONS IN INCHES AA=4" AA=3" From 36C697106DA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.17 Frames 365AT to L409AT Totally Enclosed Fan Cooled with Feet General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction COMMUTATOR END FC Motor Pricing XP COMMUTATOR END AB 0.93" SHAFT COVER FOR COMMUTATOR END EXTENSION AC Modifications Pricing Accessories & Modifications Outline Dimensions Application Information FV C For Fig. 1 ACCESSORY MOUNTING FACE AIR OUTLET N-W V XN FU FV O FU AE D G J H HOLE E 0.51" AIR INLET SHAFT COVER NO COMMUTATOR END EXTENSION 0.51" HOLE(S) FOR AA CONDUIT FN-FW Frame 365AT 366AT 368AT 407AT L407AT 409AT L409AT Frame 365AT 366AT 368AT 407AT L407AT 409AT L409AT O 17.91 17.91 17.91 20.15 20.15 20.15 20.15 P 17.9 17.9 17.9 20.38 20.38 20.38 20.38 W N BS FN 2F BA B Approx. WK2 of Arm Lb. Ft.2 15.61 18.27 22.21 35.47 35.54 43.81 43.88 Approx. Net Wt. In Lb. 830.0 940.0 1100 1380 1430 1680 1730 AD AD K approx FN-FW A U XL AF AIR INLET 2E U 2.375 2.375 2.375 2.625 2.625 2.625 2.625 pg121 Drive End Key Width 0.625 0.625 0.625 0.625 0.625 0.625 0.625 ∆ V 4.5 4.5 4.5 5.0 5.0 5.0 5.0 Thick 0.625 0.625 0.625 0.625 0.625 0.625 0.625 W 0.17 0.17 0.17 0.17 0.17 0.17 0.17 Commutator End Key Lgth. ±.03 3.5 3.5 3.5 4.0 4.0 4.0 4.0 N-W 4.75 4.75 4.75 5.25 5.25 5.25 5.25 Width 0.500 0.500 0.500 0.625 0.625 0.625 0.625 BA 5.875 5.875 5.875 6.625 6.625 6.625 6.625 FC 42.47 44.67 47.67 49.39 52.79 53.89 57.29 Thick 0.500 0.500 0.500 0.625 0.625 0.625 0.625 FN 5.42 5.42 5.42 5.42 5.42 5.42 5.42 DIMENSIONS IN INCHES Lgth. ±.03 3.0 3.0 3.0 3.5 3.5 3.5 3.5 A Max. 17.92 17.92 17.92 20.00 20.00 20.00 20.00 B Max. 14.16 15.90 19.90 20.16 20.16 24.16 24.16 DIMENSIONS IN INCHES ∆ FU FV FW 2.125 4.0 1.17 2.125 4.0 1.17 2.125 4.0 1.17 2.375 4.5 0.67 2.375 4.5 0.67 2.375 4.5 0.67 2.375 4.5 0.67 C 38.22 40.42 43.42 44.90 48.30 49.40 52.80 ‡ D 9.0 9.0 9.0 10 10 10 10 FN-FW 4.25 4.25 4.25 4.75 4.75 4.75 4.75 XO 18.62 18.62 18.62 19.62 19.62 19.62 19.62 E 7 7 7 8 8 8 8 2F 12.25 14.00 18.00 18.00 18.00 22.00 22.00 G 0.74 0.74 0.74 0.86 0.86 0.86 0.86 H 0.8125 0.8125 0.8125 0.9375 0.9375 0.9375 0.9375 J 3.26 3.26 3.26 4.00 4.00 4.00 4.00 K 2.31 2.31 2.31 2.38 2.38 2.38 2.38 N 4.92 4.92 4.92 5.42 5.42 5.42 5.42 BS XP 19.24 19.24 19.24 19.24 19.24 19.24 19.24 AA=3" 9.020 11.22 14.22 15.18 15.18 19.68 19.24 AA=4" 9.020 11.22 14.22 15.18 15.18 19.68 19.24 AA= (2) 4" 6.640 8.840 11.84 12.80 12.80 17.30 17.30 AA= Blank 12.8 12.8 17.3 17.3 DIMENSIONS IN INCHES Frame 360AT 400AT Other FW SHAFT COVER FOR COMMUTATOR END EXTENSION FW XO Terms FC C For Fig. 2 P AB 16.08 17.47 AC 12.33 13.72 AA=3" AE AF 9.000 6.44 12.95 6.44 XL 10.12 10.12 XN 7 7 AB 17.82 19.22 AC 13.2 14.6 AA=4" AE AF 9.000 8.5 12.95 8.5 XL 13.5 13.5 ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. ∆ “V” represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. XN 8.62 8.62 AB 18.72 20.12 AC 14.97 16.37 AD 3 3 AA=(2) 4" AE AF 9.000 6.75 12.95 6.75 XL 13.5 13.5 XN 13.5 13.5 AA= Blank 13.38" X 13.31" Available Drill Space AE AF XL XN Not Available 24.76 12.95 6.75 13.5 13.5 AB For shipping weight add 15% to net weight. 10 Refer to GE Energy for dimensions. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. Commutator end shaft extension is furnished only when specifically ordered, and is prepared for accessory drive. The standard single shaft machine has the commutator end bearing bracket and shaft prepared to accept acessories. For additional information, see page 4.48. From 36C697106BA 4.18 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Explosionproof Totally Enclosed Nonventilated and Fan Cooled Frames 188AT to 409AT General Information Type CD Drive End Key Depth 0.12 0.12 0.16 0.25 0.25 0.31 0.31 DIMENSIONS IN INCHES Lgth. ±.03 1.38 1.38 1.75 2.50 3.00 4.00 4.00 A 9.000 9.000 10.40 13.88 15.88 20.00 20.00 B 10.50 11.50 14.06 15.66 17.96 20.00 24.00 TENV C 19.76 21.76 28.50 - TEFC C 21.82 28.50 33.74 35.88 43.12 47.62 ‡ D 4.50 4.50 5.25 7.00 8.00 10.0 10.0 E 3.75 3.75 4.25 5.50 6.25 8.00 8.00 2E 7.50 7.50 8.50 11.0 12.5 16.0 16.0 2F 9.00 10.0 12.5 14.0 16.0 18.0 22.0 G 0.56 0.56 0.56 0.69 0.75 0.86 0.86 H 0.406 0.406 0.406 0.531 0.656 0.938 0.938 J 1.75 1.75 2.00 2.50 3.00 4.00 4.00 K 1.62 1.62 2.10 2.00 2.34 2.38 2.38 N 2.38 2.38 2.81 3.91 4.41 5.44 5.44 TENV O 9.000 9.000 10.56 - TEFC O 9.520 11.10 14.68 16.68 20.76 20.76 TENV P 9.00 9.00 10.5 - TEFC P 10.88 11.70 15.25 17.25 21.56 21.56 Outline Dimensions Approx. Approx. Net Wt. WK2 of Arm Frame In Lb. Width Lb. Ft.2 188AT 150.0 0.45 0.250 189AT 180.0 0.67 0.250 2110AT 340.0 1.71 0.312 288AT 655.0 5.36 0.500 328AT 920.0 9.67 0.500 407AT 1550 35.5 0.625 409AT 1850 43.8 0.625 Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction U 1.125 1.125 1.375 1.875 2.125 2.625 2.625 W 0.12 0.12 0.06 0.16 0.16 0.19 0.19 N-W 2.26 2.26 2.75 3.75 4.25 5.25 5.25 BA 2.74 2.74 3.50 4.75 5.25 6.62 6.62 BS 1.960 1.960 3.250 3.000 3.125 17.56 22.06 AA 1.00 1.00 1.25 2.00 2.00 3.00 3.00 AB 8.940 8.940 10.50 13.75 14.75 20.22 20.22 AF 3.60 3.60 4.25 5.25 5.25 4.69 4.69 XL 5.32 6.82 6.82 9.38 9.38 XN 3.50 3.50 4.28 5.75 5.75 9.38 9.38 XP 10.88 10.88 12.80 16.12 16.50 - ZA 2.12 2.62 3.50 - ZB 1.62 1.62 2.16 - ZC 7.600 9.600 11.50 13.88 14.88 3.090 3.090 Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. Terms ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to .03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. ∆ "V" represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. For shipping weight add 15% to net weight. AC 6.780 6.780 8.120 10.12 11.12 15.52 15.52 Other Frame 188AT 189AT 2110AT 288AT 328AT 407AT 409AT Application Information DIMENSIONS IN INCHES ∆ V 2.26 2.26 2.50 3.50 4.00 5.25 5.25 From 796C710AA, 36B550045BA, 36B549871BA, 36B550747AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.19 Explosionproof C-Face Frames 188AT to 189AT with Feet DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction FIGUrE 1 Drive End Approx. Approx. Net WK2 of Arm Wt. Frame In Lb. Lb. Ft.2 Width Fig 1 188ATC 160 0.45 0.25 189ATC 190 0.67 0.25 Fig 2 188ATC 160 0.45 0.188 189ATC 190 0.67 0.188 DIMENSIONS IN INCHES Key Lgth. Depth ±.03 A Other Terms Class II, Group E, F and G Class I, Group D TENV TEFC C C B ‡ D E 2E 2F G H J K TENV TEFC TENV TEFC O O P P N ∆ V U W ∆ V N-W BA W N-W BA AA AB 0.125 1.38 9 10.5 19.76 4.5 3.75 7.5 9 0.56 0.4062 2 1.62 2.38 0.125 1.38 9 11.5 21.76 21.82 4.5 3.75 7.5 10 0.56 0.4062 2 1.62 2.38 9 9 9.52 9 9 - 1.125 2.26 0.13 2.25 2.75 1.62 0.5 1.88 3.12 1 8.94 10 1.125 2.26 0.13 2.25 2.75 1.62 0.5 1.88 3.12 1 8.94 0.094 1.38 9 10.5 19.76 4.5 3.75 7.5 9 0.56 0.4062 2 1.62 2.38 0.094 1.38 9 11.5 21.76 21.82 4.5 3.75 7.5 10 0.56 0.4062 2 1.62 2.38 9 9 9.52 9 9 - 0.875 1.62 10 0.875 1.62 Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD Frame Cont'd Fig 1 188ATC 189ATC Fig 2 188ATC 189ATC AC AG AG AF TENV TEFC AH AJ AK BB DIMENSIONS IN INCHES BF BD BC Max Tap No. Depth 6.78 3.6 17.64 - 2.12 7.25 8.5 0.3 0.13 8.78 6.78 3.6 19.64 19.7 2.12 7.25 8.5 0.3 0.13 8.78 6.78 3.6 17.64 - 2.12 5.875 4.5 0.13 6.78 3.6 19.64 19.7 2.12 5.875 4.5 0.13 0.5 0.5 - 1.88 3.12 1.62 0.5 1.88 3.12 1 8.94 1.88 3.12 1.62 0.5 1.88 3.12 1 8.94 BS XL XN XP ZA ZB ZC .50-13 .50-13 4 4 0.75 0.75 1.96 4.5 3.5 1.96 4.5 3.5 10.88 10.88 2.62 2.62 1.88 1.88 7.6 9.6 7.14 .375-16 7.14 .375-16 4 4 0.75 0.75 1.96 4.5 3.5 1.96 4.5 3.5 10.88 10.88 2.62 2.62 1.88 1.88 7.6 9.6 FIGUrE 2 ‡ Dimensions "D" will not be exceeded. When exact dimension is required, shims up to.03 inches may be necessary where dimension "D" is 8 inches or less. When dimension "D" is over 8 inches, shims up to .06 inch may be necessary. ∆ "V" represents minimum length of shaft available for hubs. Shaft diameters 1.5 inches and smaller will come within the limits of +0.0000 inch -0.0005 inch. Diameters larger than 1.5 inches will come within the limits of +0.0000 inch -0.0010 inch. Shaft runout on diameters 1.625 inches and smaller shall not exceed .002 inch indicator reading. Diameters larger than 1.625 inches shall not exceed .003 inch indicator reading. For shipping weight add 15% to net weight. Conduit box will be assembled on the right hand side facing the commutator end for motors, and on the left hand side facing the commutator end for generators. Conduit box will be assembled on opposite side of frame, if so specified. Conduit box may be oriented to accommodate customers’ application. Dimensions pertaining to conduit boxes vary according to rating. For frames CD2110AT and CD288AT the rabbet diameter will be concentric with the shaft within .004 inches and the mounting face will be square with the shaft within .004 inch tolerance on "AK" dimension +.000 inch -.003 inch. For frames 328 the rabbet diameter will be concentric with the shaft within .007 inches and the mounting face will be square with the shaft within .007 inch tolerance on "AK" dimension +.000 inch -.005 inch. From 36C697570AA 4.20 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. TEAAC Totally Enclosed Air-To-Air Cooled Frames 366AT to L508AT General Information Type CD Cooler Weight in Lb. 230 252 425 425 440 440 425 430 435 445 460 470 610 610 610 625 660 675 XA 20.24 20.24 24.00 24.00 24.00 24.00 24.00 24.00 24.00 24.00 24.00 24.00 30.62 30.62 30.62 30.62 30.62 30.62 XB 10.12 10.12 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 15.31 15.31 15.31 15.31 15.31 15.31 XC 31.44 34.44 37.88 37.88 42.38 42.38 37.88 39.62 41.88 43.62 46.88 48.62 43.50 43.50 43.50 45.25 48.50 50.25 XD 33.70 33.70 36.96 36.96 36.96 36.96 41.06 41.06 41.06 41.06 41.06 41.06 47.88 47.88 47.88 47.88 47.88 47.88 XE 27.30 27.30 29.65 29.65 29.65 29.65 33.75 33.75 33.75 33.75 33.75 33.75 38.50 38.50 38.50 38.50 38.50 38.50 XF 6.29 6.29 6.88 6.88 6.88 6.88 8.75 8.75 8.75 8.75 8.75 8.75 8.53 8.53 8.53 8.53 8.53 8.53 XG 0.88 0.88 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.18 1.18 1.18 1.18 1.18 1.18 XH 12.92 12.92 15.88 15.88 15.88 15.88 15.88 15.88 15.88 15.88 15.88 15.88 19.12 19.12 19.12 19.12 19.12 19.12 XJ 11.70 11.70 13.75 13.75 13.75 13.75 13.75 13.75 13.75 13.75 13.75 13.75 17.19 17.19 17.19 17.19 17.19 17.19 XK 3.44 3.44 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50 XL 6.60 6.60 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 8.75 8.75 8.75 8.75 8.75 8.75 XM 2.5 2.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 XN 0.75 0.75 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 XW 8.740 8.740 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 13.25 13.25 13.25 13.25 13.25 13.25 XY 18.75 18.75 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 15.00 15.00 15.00 15.00 15.00 15.00 XZ 10.38 10.38 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 13.50 13.50 13.50 13.50 13.50 13.50 Application Information Cooler Type Z Z A A A A A A A A A A B B B B B B Other Frame CD366AT CD368AT CD407AT L407AT CD409AT L409AT CD504AT L504AT CD506AT L506AT CD508AT L508AT CD504AT L504AT CD506AT L506AT CD508AT L508AT Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Terms Standard location of cooler conduit box is on the same side as machine conduit box, however, box will be located on opposite side if specified. Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward, or horizontally. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.21 TEAAC Totally Enclosed Air-To-Air Cooled Frames 5010AY Approximate cooler weight Aluminum 950 lbs Stainless Steel 1209 lbs Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD 4.22 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 327AT to L508AT Totally Enclosed Air-Over-Frame General Information Type CD Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Locations of Blowers shown are preferred locations Blower can be rotated about blower axis to any position in 90° increments where conditions permit. Accessories & Modifications Modifications Pricing N.A. = Not Applicable Outline Dimensions Locations of Blowers shown are preferred locations Blower can be rotated about blower axis to any position in 90° increments where conditions permit. Application Information N.A. = Not Applicable XA 16.40 16.40 18.40 18.40 18.40 20.00 20.00 20.00 20.00 25.24 25.24 25.24 25.24 XB 0.32 0.32 0.42 0.42 0.42 0.42 0.42 0.42 0.42 0.45 0.45 0.45 0.45 XC 9.260 9.260 10.22 10.22 10.22 11.22 11.22 11.22 11.22 13.73 13.73 13.73 13.73 XD 2.68 2.68 1.45 1.45 1.45 1.45 1.45 1.45 1.45 N.A. N.A. N.A. N.A. XE 17.98 19.86 16.11 18.42 21.42 21.42 21.42 25.92 25.92 21.29 25.29 30.29 32.05 XF 1.56 1.56 2.61 2.61 2.61 2.61 2.61 2.61 2.61 2.60 2.60 2.60 2.60 XG 6.250 6.250 7.480 7.480 7.480 7.380 10.78 7.380 10.78 11.20 11.39 11.39 11.39 XH 14.52 14.52 15.23 15.23 15.23 15.23 16.23 16.23 16.23 20.04 20.04 20.04 20.04 XJ 19.08 19.08 19.73 19.73 19.73 20.73 20.73 20.73 20.73 28.47 28.47 28.47 28.47 XK 4.88 4.88 4.90 4.90 4.90 4.90 4.90 4.90 4.90 8.53 8.53 8.53 8.53 XL 10.38 10.38 10.51 10.51 10.51 10.51 10.51 10.51 10.51 11.85 11.85 11.85 11.85 XM 8.880 8.880 8.780 8.780 8.780 8.780 8.780 8.780 8.780 14.91 14.91 14.91 14.91 XN 3.15 3.15 3.38 3.38 3.38 3.38 3.38 3.38 3.38 4.37 4.37 4.37 4.37 XP 5.630 7.050 5.860 5.860 5.860 5.810 5.810 5.810 5.810 4.820 8.820 13.82 13.82 Xr 2.81 2.81 2.82 2.82 2.82 2.82 2.82 2.82 2.82 5.57 5.57 5.57 5.57 XS 10.72 12.59 7.780 8.880 10.38 11.24 11.24 13.49 13.49 11.02 15.02 20.02 20.02 XT 15.45 15.90 14.46 16.66 19.66 19.61 23.01 24.11 27.51 23.30 23.49 23.49 25.25 XU 17.65 17.65 17.98 17.98 17.98 19.51 19.51 19.51 19.51 27.36 27.36 27.36 27.36 XV 13.09 13.09 14.23 14.23 14.23 15.01 15.01 15.01 15.01 19.93 19.93 19.93 19.93 XW 9.070 9.070 9.840 9.840 9.840 10.84 10.84 10.84 10.84 13.93 13.93 13.93 13.93 From 36C697331AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.23 Other DIMENSIONS IN INCHES Terms Frame CD327AT CD328AT CD365AT CD366AT CD368AT CD407AT CDL407AT CD409AT CDL409AT CD504AT CD506AT CD508AT CDL508AT Approx. Net Wt. in Lb. 33 60 54 56 59 60 60 70 70 75 84 89 92 Dimensions, Air Openings Frames 210AT to 5010AY DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Modifications Pricing Motor Pricing General Information Type CD FIGUrE 2 Accessories & Modifications FIGUrE 1 Application Information Outline Dimensions FIGUrE 3 DIMENSIONS IN INCHES Frame CD210AT CD258AT CD259AT CD287AT CD288AT CD320AT CD360AT CD400AT CDL400AT CD500AT CDL500AT CD5010AY Figure No. 1 CA 4.59 CB 3.24 CC 2.38 CD 0.50 CE 2.62 CF 0.34 CG - DA 6.710 DB 5.400 DC 4.20 DD 0.50 DE 4.42 DF 0.34 DG 5.00 DJ 5.640 DK 4.42 DL 0.61 DM - 1 5.03 3.52 2.38 0.48 2.62 0.34 - 6.610 5.140 4.20 0.48 4.42 0.34 6.00 6.760 5.42 0.67 - 1 5.53 3.94 2.88 0.58 3.32 0.34 - 8.210 6.440 5.00 0.68 5.50 0.40 7.00 7.760 6.22 0.77 - 1 2 3 3 5.85 6.30 6.98 6.98 4.12 4.80 5.22 5.22 2.88 3.06 3.19 3.19 0.58 0.81 0.77 0.77 3.32 3.70 3.70 3.70 0.34 0.56 0.46 0.46 - 7.950 9.600 9.120 12.52 6.300 7.860 7.240 10.64 5.00 5.44 5.44 7.74 0.68 0.76 0.72 0.72 5.50 5.80 5.80 8.20 0.40 0.62 0.56 0.56 8.00 10.4 10.4 10.4 8.760 11.30 12.74 12.74 7.22 9.24 4.62 4.62 0.77 4 5 5 0.78 0.78 2 5 4 3 8.18 5.96 3 8.40 5.90 4.26 0.94 5.00 0.54 8 13.48 11.42 9.36 0.86 9.80 0.64 12.8 14.70 5.14 0.88 4 4.26 0.82 5.00 0.44 0 13.48 11.42 9.36 0.86 9.80 0.64 12.8 14.70 5.14 0.88 4 Terms Other For shipping weight add 15% to net weight. From 533C118AA 4.24 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Blower Unit, Commutator End Mounted Frames CD180AT to CD280AT General Information Type CD Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Application Information Outline Dimensions Accessories & Modifications CD180AT DIMENSIONS IN INCHES Type CD Frame Approx. Net Wt. in Lb. XA XB XD XE XF XJ XK XM XS 210AT* 20 17.61 12.36 14.62 10.76 9.520 5.32 6.88 2.38 6.680 250AT* 20 19.61 13.36 14.62 10.66 9.520 5.32 6.88 2.38 6.680 280AT 28 23.10 16.10 21.82 15.34 13.53 6.82 6.88 2.81 10.38 * On CD210AT & CD250AT frames, when sidemounted, blower can only be mounted opposite conduit box. www.gemotors.com • 800-541-7191 NOTE: The required air flow is obtained only when the blower motors are operated in the correct direction of rotation. When facing the air inlet, the blower wheel should rotate counterclockwise. Check the blower motor for correct direction of rotation by running it in both directions and observing the quantity of air discharged. The direction of rotation which gives the greatest air flow is the correct one. Blower motors can be reversed by interchanging the external connections to any two of the three line leads. GEP387M 09/11 • Prices and data subject to change without notice. 4.25 Terms Other CD210AT-280AT Blower Unit, Commutator End Mounted Frames 320AT DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD DIMENSIONS IN INCHES Approx. Net Wt. in Lb. XA XB XD XE XF XJ XK XM XS XT 320AT 61 27.87 19.87 22.94 16.95 14.75 10.2 13.38 4.49 12.17 0.53 Type CD Frame Approx. Net Wt. in Lb. XA XB XD XE XF XJ XK XM XS XT 320AT 65 27.81 19.87 22.94 7.39 14.75 10.2 13.38 4.49 12.17 0.53 Terms Other Application Information Outline Dimensions Type CD Frame DIMENSIONS IN INCHES NOTE: The required air flow is obtained only when the blower motors are operated in the correct direction of rotation. When facing the air inlet, the blower wheel should rotate counterclockwise. Check the blower motor for correct direction of rotation by running it in both directions and observing the quantity of air discharged. The direction of rotation which gives the greatest air flow is the correct one. Blower motors can be reversed by interchanging the external connections to any two of the three line leads. 36A167799HN, 36A167799HS, 36A167799HT 4.26 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Blower Unit, Commutator End Mounted Frames 360AT to 400AT General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction XB XD XE Fig. 1 XE Fig. 2 CD360AT 65 28.80 19.80 23.06 18.13 6.51 CD400AT 65 30.52 20.52 23.19 17.69 7.09 CDL400AT 70 30.52 20.52 23.19 19.87 4.91 DIMENSIONS IN INCHES Type CD Frame XJ XK XM XS XT XF CD360AT 8.93 13.38 3.22 12.09 1.8 14.90 CD400AT 8.93 13.38 3.22 12.04 1.8 15.07 CDL400AT 8.93 13.38 3.22 12.03 1.8 15.07 Frame CD360AT CD400AT Blower Motor Conduit Hole .875 Diameter Hole in Blower Motor CND Box FIGUrE 2 SIDE MOUNTED rIGHT HAND SIDE FACING COMMUTATOr END Terms Other Application Information From 36A167799HP Outline Dimensions NOTE: The required air flow is obtained only when the blower motors are operated in the correct direction of rotation. When facing the air inlet, the blower wheel should rotate clockwise. Check the blower motor for correct direction of rotation by running it in both directions and observing the quality of air discharged. The direction of rotation which gives the greatest air flow is the correct one. Blower motors can be reversed by interchanging the external connections to any two of three line leads. Motor Pricing XA Modifications Pricing FIGUrE 1 TOP MOUNTED Approx. Net Wt. in Lb. Accessories & Modifications From 36A167799HM DIMENSIONS IN INCHES Type CD Frame FIGUrE 3 SIDE MOUNTED LEFT HAND SIDE FACING COMMUTATOr END From 36A167799HR www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.27 Blower Unit, Commutator End Mounted Frames 500AT DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction DIMENSIONS IN INCHES Type CD Frame Approx. Net Wt. in Lb. XA XB XD XE Fig. 1 XE Fig. 2 CD500AT 83 43.05 30.55 32.58 22.95 8.35 DIMENSIONS IN INCHES Type CD Frame XJ XK XM XS XT XF CD500AT 15.17 20.36 6.47 15.65 1.25 20.43 Frame Blower Motor Conduit Hole CD500AT 1.09" Diameter Hole in Blower Motor CND Box NOTE: The required air flow is obtained only when the blower motors are operated in the correct direction of rotation. When facing the air inlet, the blower wheel should rotate counterclockwise. Check the blower motor for correct direction of rotation by running it in both directions and observing the quality of air discharged. The direction of rotation which gives the greatest air flow is the correct one. Blower motors can be reversed by interchanging the external connections to any two of three line leads. From 36A167799GK FIGUrE 1 TOP MOUNTED From 36A167799GN FIGUrE 2 SIDE MOUNTED rIGHT HAND SIDE FACING COMMUTATOr END Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD FIGUrE 3 SIDE MOUNTED LEFT HAND SIDE FACING COMMUTATOr END From 36A167799GL 4.28 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 6050 to 6066 Dripproof Fully Guarded, Separately Ventilated and Enclosed Separately Ventilated General Information Type CD B 2F C CD6050 3900 160 42.7 32 59.71 CD6052 4200 180 44.8 36 CD6054 4100 170 47.0 CD6055 4700 210 47.4 CD6057 4500 190 CD6058 5300 CD6059 5000 CD6062 CD6063 CD6066 FC Standard Box Oversize Box Frame 66.96 16.59 14.59 CD6050 61.81 69.06 18.69 16.69 CD5052 36 64.01 71.26 14.59 13.59 CD6055 36 64.41 71.66 21.29 19.29 CD6058 49.1 40 66.11 73.36 16.69 15.69 CD6062 240 50.6 40 67.61 74.86 24.49 22.49 CD6054 220 51.7 40 68.71 75.96 19.29 18.29 CD6057 6000 280 54.6 45 71.61 78.86 28.49 26.49 CD6059 5600 250 54.9 45 71.91 79.16 22.49 21.49 CD6063 6300 290 58.9 50 75.91 83.16 26.49 25.49 CD6066 AB AF XA Standard 31.72 10 20 Oversize 35.75 12 24 Standard 35.72 12 24 Oversize 39.72 13 26 Splashproof machines will have additional covers, but all dimensions will remain the same. Air inlet can be provided at drive end at top, bottom, or either side if so specified. Totally enclosed separately ventilated enclosures can be provided with both air inlet and outlet at top, bottom, or either side. For shipping weight, add 15% to net weight. Terms Other Commutator end shaft extension is furnished only when specifically ordered. Standard conduit box location is right hand side for motor and left hand side for generator facing commutator end. Conduit box can be assembled on the oppo site side of frame, or assembled so that entrance can be made from above, from commutator end, or from drive end if so specified. Fixed termination is provided for customer connections. Box Outline Dimensions Frame Approx. Wk2 of Armature Ft. Lb. Application Information CONDUIT BOX DIMENSIONS BS Approx. Net Wt. in Lb. Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706021AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.29 Frames 6154 to 6177 Dripproof Fully Guarded, Separately Ventilated and Enclosed Separately Ventilated DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction CONDUIT BOX DIMENSIONS BS Frame Approx. Net Wt. in Lb. Approx. Wk2 of Armature Ft. Lb. B 2F C CD6154 5800 390 46.8 36 65.61 CD6157 6500 440 49.4 40 CD6160 7300 510 52.6 CD6163 6300 420 55.4 CD6164 8300 600 CD6165 7000 CD6168 7800 CD6169 CD6173 CD6177 FC Standard Box Oversize Box Frame 74.06 20.79 18.79 CD6154 68.21 76.66 23.39 21.39 CD6157 42 71.41 79.86 26.59 24.59 CD6160 45 74.21 82.66 19.79 16.79 CD6164 56.6 45 75.41 83.86 30.59 28.59 CD6169 480 58.0 48 76.81 85.26 22.39 19.39 CD6163 550 61.2 50 80.01 88.46 25.59 22.59 CD6165 9500 700 61.2 50 80.01 88.46 35.19 33.19 CD6168 8800 640 65.2 56 84.01 92.46 29.59 26.59 CD6173 10000 740 69.8 60 88.61 97.06 34.19 31.19 CD6177 Commutator end shaft extension is furnished only when specifically ordered. Standard conduit box location is right hand side for motor and left hand side for generator facing commutator end. Conduit box can be assembled on the opposite side of frame, or assembled so that entrance can be made from above, from commutator end, or from drive end if so specified. Fixed termination is provided for customer connections. Box AB AF XA Standard 34.32 10 20 Oversize 38.32 12 24 Standard 38.32 12 24 Oversize 42.32 15 26 Splashproof machines will have additional covers, but all dimensions will remain the same. Air inlet can be provided at drive end at top, bottom, or either side if so specified. Totally enclosed separately ventilated enclosures can be provided with both air inlet and outlet at top, bottom, or either side. For shipping weight, add 15% to net weight. Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD From 36C706022AA 4.30 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 6259 to 6280 Dripproof Fully Guarded, Separately Ventilated and Enclosed Separately Ventilated General Information Type CD B 2F C CD6259 9800 960 51.7 40 71.71 CD6262 11100 1120 54.9 45 CD6266 12700 1320 58.9 CD6268 10400 1020 60.3 CD6270 11700 1180 CD6271 14500 1550 CD6275 13300 CD6280 15200 FC Standard Box Oversize Box Frame 81.960 24.89 22.89 CD6259 74.91 85.160 28.09 26.09 CD6262 50 78.91 89.160 32.09 30.09 CD6266 50 80.31 90.560 23.89 20.89 CD6271 63.5 52 83.51 93.760 27.09 24.09 CD6268 63.5 52 83.51 93.760 36.69 34.69 CD6270 1380 67.5 56 87.51 97.760 31.09 28.09 CD6275 1610 72.1 63 92.11 102.36 35.69 32.69 CD6280 AB AF XA 38.22 10 20 Oversize 42.22 12 24 Standard 42.22 12 24 Oversize 46.22 15 30 Splashproof machines will have additional covers, but all dimensions will remain the same. Air inlet can be provided at drive end at top, bottom, or either side if so specified. Totally enclosed separately ventilated enclosures can be provided with both air inlet and outlet at top, bottom, or either side. For shipping weight, add 15% to net weight. Terms Other Commutator end shaft extension is furnished only when specifically ordered. Standard conduit box location is right hand side for motor and left hand side for generator facing commutator end. Conduit box can be assembled on the opposite side of frame, or assembled so that entrance can be made from above, from commutator end, or from drive end if so specified. Fixed termination is provided for customer connections. Box Standard Outline Dimensions Frame Approx. Wk2 of Armature Ft. Lb. Application Information CONDUIT BOX DIMENSIONS BS Approx. Net Wt. in Lb. Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706023AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.31 Frames 6766 to 6785 Dripproof Fully Guarded, Separately Ventilated and Enclosed Separately Ventilated DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction BS Frame Approx. Net Wt. in Lb. Approx. Wk2 of Armature Ft. Lb. B 2F C CD6766 12100 1550 55.18 45 80.98 CD6770 14000 1850 58.68 50 CD6771 12400 1650 59.48 50 CD6774 15200 2200 62.68 CD6776 14000 1950 62.98 CD6778 15600 2300 CD6779 17200 CD6785 17600 CONDUIT BOX DIMENSIONS FC Standard Box Oversize Box Frame 93.930 23.67 20.67 CD6766 84.48 97.430 27.17 24.17 CD6770 85.28 98.230 23.67 20.67 CD6771 55 88.48 101.43 31.17 28.17 CD6774 55 88.78 101.73 27.17 24.17 CD6776 66.98 60 92.78 105.73 31.17 28.17 CD6778 2700 67.68 60 93.48 106.43 36.17 33.17 CD6779 2750 71.98 65 97.78 110.73 36.17 33.17 CD6785 Commutator end shaft extension is furnished only when specifically ordered. Standard conduit box location is right hand side for motor and left hand side for generator facing commutator end. Conduit box can be assembled on the opposite side of frame, or assembled so that entrance can be made from above, from commutator end, or from drive end if so specified. Fixed termination is provided for customer connections. Box AB AF XA Standard 43.75 12 24 Oversize 47.75 15 30 Splashproof machines will have additional covers, but all dimensions will remain the same. Air inlet can be provided at drive end at top, bottom, or either side if so specified. Totally enclosed separately ventilated enclosures can be provided with both air inlet and outlet at top, bottom, or either side. For shipping weight, add 15% to net weight. Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD From 36C706024AA 4.32 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Frames 6873 to 6896 Dripproof Fully Guarded, Separately Ventilated and Enclosed Separately Ventilated General Information Type CD B 2F C CD6873 16000 2900 58.9 50 87.630 CD6876 17700 3230 62.9 55 CD6881 20300 4170 67.4 CD6882 16800 3130 67.5 CD6885 18500 3460 CD6887 23500 CD6890 CD6896 CONDUIT BOX DIMENSIONS FC Standard Box Oversize Box Frame 100.58 30.8 27.8 CD6873 91.630 104.58 34.8 31.8 CD6876 60 96.130 109.08 39.3 36.3 CD6881 60 96.230 109.18 27.8 24.8 CD6887 71.5 65 100.23 113.18 31.8 28.8 CD6882 5480 72.9 65 101.63 114.58 44.8 41.8 CD6885 21000 4400 76.0 70 104.73 117.68 36.3 33.3 CD6890 24200 5710 81.5 75 110.23 123.18 41.8 38.8 CD6896 AB AF XA Standard 46.75 12 24 Oversize 50.75 15 30 Standard 50.75 15 30 Oversize 56.75 18 36 Splashproof machines will have additional covers, but all dimensions will remain the same. Air inlet can be provided at drive end at top, bottom, or either side if so specified. Totally enclosed separately ventilated enclosures can be provided with both air inlet and outlet at top, bottom, or either side. For shipping weight, add 15% to net weight. Terms Commutator end shaft extension is furnished only when specifically ordered. Standard conduit box location is right hand side for motor and left hand side for generator facing commutator end. Conduit box can be assembled on the opposite side of frame, or assembled so that entrance can be made from above, from commutator end, or from drive end if so specified. Fixed termination is provided for customer connections. Box Application Information Frame Approx. Wk2 of Armature Ft. Lb. Other BS Approx. Net Wt. in Lb. Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706025AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.33 Frames 6977 to 6999 Dripproof Fully Guarded, Separately Ventilated and Enclosed Separately Ventilated DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction BS Frame Approx. Net Wt. in Lb. Approx. Wk2 of Armature Ft. Lb. B 2F C CD6977 23400 5100 64.4 55 95.130 CD6981 26000 6000 68.4 60 CD6985 28700 6350 73.4 CD6986 24300 5250 73.0 CD6990 26900 6200 CD6991 31700 8850 CD6996 29600 CD6999 34400 CONDUIT BOX DIMENSIONS FC Standard Box Oversize Box Frame 110.08 34.81 31.81 CD6977 99.130 114.08 38.81 35.81 CD6981 65 104.13 119.08 43.81 40.81 CD6985 65 103.73 118.68 31.81 28.81 CD6991 77.0 70 107.73 122.68 35.81 32.81 CD6986 79.9 70 110.63 125.58 50.31 47.31 CD6990 6550 82.0 75 112.73 127.68 40.81 37.81 CD6996 9050 88.5 80 119.23 134.18 47.31 44.31 CD6999 Commutator end shaft extension is furnished only when specifically ordered. Standard conduit box location is right hand side for motor and left hand side for generator facing commutator end. Conduit box can be assembled on the opposite side of frame, or assembled so that entrance can be made from above, from commutator end, or from drive end if so specified. Fixed termination is provided for customer connections. Box AB AF XA Standard 51.75 12 24 Oversize 55.75 15 30 Standard 55.75 15 30 Oversize 61.75 18 36 Splashproof machines will have additional covers, but all dimensions will remain the same. Air inlet can be provided at drive end at top, bottom, or either side if so specified. Totally enclosed separately ventilated enclosures can be provided with both air inlet and outlet at top, bottom, or either side. For shipping weight, add 15% to net weight. Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD From 36C706026AA 4.34 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Blower Unit, without Filters Frames 6000 to 6900 General Information Type CD Approx. Net Wt. in Lb. XA XB XC XD XE XF XG CD6000 290 54.86 43.25 14.38 4.91 29.44 23.20 4.50 CD6100 419 62.26 48.35 17.23 4.83 35.16 27.79 5.39 CD6200 469 71.31 56.25 17.52 4.97 36.02 30.08 4.71 Frame Approx. Net Wt. in Lb. XA XB XC XD XE CD6700 706 80.88 63.75 21.40 4.89 41.56 CD6800 732 86.88 69.75 19.92 7.14 44.31 CD6900 770 96.88 79.75 16.90 7.39 44.56 Terms Other Application Information Outline Dimensions Frame Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36B476120AA, 36B476120AB www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.35 Blower Unit, with Filters Frames 6000 to 6900 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Frame Approx. Net Wt. in Lb. XA XB XC XD XE XF XG XH CD6000 398 58.88 43.25 14.79 9.760 54.23 10.16 8.060 4.50 CD6100 525 63.98 48.35 12.79 13.48 60.03 11.70 9.900 5.39 CD6200 573 71.88 56.25 12.79 13.34 60.75 11.70 10.49 4.71 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD Frame Approx. Net Wt. in Lb. XA XB XC XD XE XF XG CD6700 848 91.82 63.75 21.63 17.98 66.36 11.55 12.81 CD6800 874 97.82 69.75 20.14 15.73 66.86 11.80 14.30 CD6900 912 107.82 79.75 17.13 15.48 66.86 11.80 17.30 From 36B476120BA, 36B476120BB 4.36 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Blower Unit, with Filters Splashproof Fully Guarded Frames 6000 to 6900 General Information Type CD Approx. Net Wt. in Lb. XA XB XC XD XE XF XG XH CD6000 443 55.88 43.25 14.79 9.760 65.43 10.16 8.06 4.50 CD6100 570 63.98 48.35 12.79 13.48 71.23 11.70 9.90 5.39 CD6200 618 71.88 56.25 12.79 13.34 71.95 11.70 10.49 4.71 Frame Approx. Net Wt. in Lb. XA XB XC XD XE XF CD6700 938 91.820 63.75 21.63 17.98 77.56 11.55 964 97.820 69.75 20.14 15.73 78.06 11.80 1002 107.82 79.75 17.13 15.48 78.06 11.80 Terms CD6800 CD6900 Other Application Information Outline Dimensions Frame Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36B476120CA, 36B476120CB www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.37 TEAAC Totally Enclosed Air-To-Air Cooled CD6000 to CD6200 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction FIGUrE 2 FIGUrE 1 Frame Fig. Approx. Net Wt. in Lb. XA XB XC XD XE XF XG XH XJ XK XM XP CD6000 1 1300 84.50 46.0 16 32 18 36 20.56 70.34 2.16 6.500 7.84 25 CD6100 2 1700 97.60 51.1 18 36 20 40 18.56 77.22 5.91 8.120 5.84 27 CD6200 2 2100 105.5 59.0 18 36 20 40 18.56 81.97 3.90 10.56 5.84 29 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD From 36C706021AJ 4.38 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. TEAAC Totally Enclosed Air-To-Air Cooled CD6700 to CD6900 General Information Type CD Fig. Approx. Net Wt. in Lb. XA XB XC XD XE XF XG XH XJ XK XM XP CD6700 1 2400 114.0 63 23.25 46.5 24.44 48.88 27 89.940 3.06 9.440 5.39 30 CD6800 2 2900 122.5 70 25.50 51.0 26.88 53.75 30 90.030 1.84 11.12 6.03 32 CD6900 2 3900 140.5 80 25.50 51.0 26.88 53.75 30 101.15 1.84 11.12 5.77 32 Terms Other Application Information Frame Outline Dimensions FIGUrE 2 FIGUrE 1 Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706024AJ www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.39 TEWAC Totally Enclosed Water-To-Air Cooled CD6000 to CD6200 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Motor Pricing General Information Type CD FIGUrE 2 Accessories & Modifications Modifications Pricing FIGUrE 1 FIGUrE 2 CD6200 Frame Approx. Net Wt. in Lb. XA XB XC XD XE XF XG XH XJ XK XM XP Xr XS CD6000 1500 65.63 40.13 77.73 19.5 31.63 21.00 27.44 16.75 37.75 1.75 73.70 26.25 15.5 11.1 CD6100 1500 74.98 45.23 87.08 22.5 34.63 25.25 30.44 19.75 29.75 1.75 89.98 27.13 20.9 16.5 CD6200 1800 78.63 53.13 91.24 27.0 39.13 21.50 34.94 24.25 36.25 2.25 92.28 26.88 20.9 16.5 Terms Other Application Information Outline Dimensions FIGUrE 1 CD6000 & CD6100 From 36C706021AK 4.40 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. TEWAC Totally Enclosed Water-To-Air Cooled CD6700 to CD6900 General Information Type CD Approx. Net Wt. in Lb. XA XB XC XD XE XF XG XH XJ XK XM XP Xr XS XT CD6700 2200 92.070 58.13 104.16 25.50 37.63 29.43 33.44 22.75 43.75 4.25 93.05 30.63 18.50 13.56 18.0 CD6800 2800 116.13 64.13 128.23 27.00 39.13 47.50 34.84 24.25 45.25 4.25 115.0 36.33 28.00 23.06 18.0 CD6900 3000 116.25 73.75 127.70 31.57 43.57 38.37 39.38 28.75 53.75 6.75 117.8 42.75 23.81 18.86 22.5 Terms Other Application Information Frame Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706024AK www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.41 Dimensions, Air Openings Frames 6050 to 6066 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Motor Pricing General Information Type CD Accessories & Modifications Modifications Pricing FIGUrE 1 FIGUrE 2 Terms Other Application Information Outline Dimensions (SAME AS FIGUrE 1 EXCEPT AS SHOWN) Frame Figure CD6050 1 CD6054 2 CD6052 1 CD6057 2 CD6055 1 CD6059 2 CD6058 1 CD6063 2 CD6062 1 CD6066 2 XA 14.8 16.9 19.5 22.7 26.7 From 36C706070BA 4.42 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Dimensions, Air Openings Frames 6154 to 6177 General Information Type CD Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Accessories & Modifications Modifications Pricing FIGUrE 1 FIGUrE 2 Application Information Outline Dimensions (SAME AS FIGUrE 1 EXCEPT AS SHOWN) 1 CD6163 2 CD6157 1 CD6165 2 CD6160 1 CD6168 2 CD6164 1 CD6173 2 CD6169 1 CD6177 2 XA 17.0 Other Figure 19.6 22.8 26.8 Terms Frame CD6154 31.4 From 36C706070BB www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.43 Dimensions, Air Openings Frames 6259 to 6280 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Modifications Pricing Motor Pricing General Information Type CD Accessories & Modifications FIGUrE 1 Outline Dimensions FIGUrE 2 Terms Other Application Information (SAME AS FIGUrE 1 EXCEPT AS SHOWN) Frame Figure CD6259 1 CD6268 2 CD6262 1 CD6270 2 CD6266 1 CD6275 2 CD6271 1 CD6280 2 XA 20.1 23.3 27.3 31.9 From 36C706070BC 4.44 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Dimensions, Air Openings Frames 6766 to 6785 General Information Type CD Frame XA CD6766 27.67 CD6770 31.17 CD6774 35.17 CD6779 40.17 CD6771 27.67 CD6776 31.17 CD6778 35.17 CD6785 40.17 XB XC XD 7.50 17.0 25.25 9.65 21.3 29.55 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706070AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.45 Dimensions, Air Openings Frames 6873 to 6896 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD Frame XA CD6873 30.55 CD6876 34.55 CD6881 39.05 CD6887 44.55 CD6882 30.55 CD6885 34.55 CD6890 39.05 CD6896 44.55 XB XC XD 6.20 14.4 18.0 10.5 23.0 26.6 From 36C706070AB 4.46 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Dimensions, Air Openings Frames 6977 to 6999 General Information Type CD Frame XA CD6977 33.97 CD6981 37.97 CD6985 42.97 CD6991 49.47 CD6986 33.97 CD6990 37.97 CD6996 42.97 CD6999 49.47 XB XC XD 7.20 16.4 19.8 11.5 25.0 28.4 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706070AC www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.47 Accessory Mountings Frames 180AT to 5010AY For All Motors Except Those with TEFC Enclosure DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD NOTES: Other Accessories shaft as shown furnished on all machines not having commutator end shaft extensions. Accessories shaft is suitable for driving tachometer and speed limit switch. Tapped hole is not concentric with shaft diameters. Terms For brake application a keyed commutator end shaft extension is required. Standard Commutator End Bracket and Accessory Shaft Extension on CD180AT-CD500AT Machines (Dimensions do not apply to TEFC machines.) 4.48 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. From 36C697103AA Accessory Mountings Frames 6000 to 6900 General Information Type CD Frame CD6000 CD6100 CD6200 XAO 11.125 11.123 11.125 11.123 14.375 14.372 CD6700 14.375 CD6800 14.372 CD6900 14.375 14.372 XBO XCO XDO XE XFO XG XH XJO 11.75 11.75 9.875 0.12 3.875 1.00-8 2.38 1.5 11.75 11.75 9.750 0.12 4.500 1.00-8 2.38 1.5 15.00 13.25 11.25 0.12 5.375 1.50-6 3.50 2.0 15.00 16.00 14.00 0.12 6.215 1.50-6 3.50 2.0 15.00 17.50 15.50 0.14 6.215 1.50-6 3.50 2.0 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36C706009AA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.49 Accessory Couplings Frames 180AT to 500AT and 6000 to 6900 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD “A” Diameter 0.6255 0.6250 Outline Dimensions TORSIONALLY RIGID COUPLING RATED AT .17 HP PER 100 RPM 0.7505 0.7500 0.5005 0.5000 0.3130 Depth 0.1875 0.0937 0.1875 0.0937 OMIT OMIT Terms Other Application Information 0.3123 Key Way Width 4.50 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Accessory Adapters Frames 180AT to 500AT and 6000 to 6900 General Information Type CD BC42/BC46 tachometer adapter mounts on bracket (See motor outline.) Terms Other Application Information Outline Dimensions Form "Y" tachometer adapter mounts on bracket (See motor outline.) Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.51 Speed Limit Device Frames 180AT to 6900 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction NOTES: On frames CD180AT through CD320AT, the speed limit switch can be mounted with condulet on right or left side, but will be mounted on same side as machine leads unless otherwise specified. Providing mounting conditions permit, condulet may be turned so that entrance can be made in any direction. FOr FrAMES CD180AT - CD500AT WEIGHT - 14 LB. Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD Frame AB AC P CD180AT 7.59 6.43 8.86 CD210AT Thru CD500AT 7.92 6.76 9.73 On frames CD360AT through CD500AT, the speed limit switch can be mounted with condulet on right or left side, or top or bottom, but will be mounted on same side as machine leads unless otherwise specified. Providing mounting conditions permit, condulet may be turned so that entrance can be made in any direction. From 36A168434AC Other Application Information FOr FrAMES CD6000-CD6900 Frame CD6000 Terms CD6100 CD6200 Thru CD6900 Approx. Net Wt. in Lbs. XA XB 34 13.00 10.00 50 16.25 11.75 Limit switch may be arranged for circuit opening or circuit closing or both. Limit switch may be mounted on either side, but will be mounted on the same side as machine leads unless otherwise specified. From 36C695008RA 4.52 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Avtron Tachometer Frames 180AT to 6900 General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction 2.54 [64.5] 3.83 [97.3] 0.24 [6.1] Ø0.562 [14.3] - 4 HOLES 4.66 [118.4] LED ALARM INDICATOR Motor Pricing 45° OPTIONAL 2nd ISOLATED OUTPUT 4.38 [111.1] COVER PLATE SINGLE OUTPUT ONLY Ø7.250 [Ø184.15] 0.53 [13.5] Ø 8.5015 8.5035 Ø 8.500 8.498 215.99 ] [ Ø 215.94 215.85 ] [ Ø 215.90 Modifications Pricing 0.19 [4.8] OPTION "N" 1/2" FLEXIBLE WATERPROOF CONDUIT 1/2-14 NPT OPTIONS "P","V"&"G" PLUG-IN INDUSTRIAL CONNECTOR Accessories & Modifications 5 FT [1524.0] MIN Ø9.00 [Ø228.6] 1.29 [32.8] 1/8-27 NPT DRAIN PLUG NOTE: IF THE ENCODER WILL BE EXPOSED TO WATER SPRAY, THE BOTTOM PIPE PLUG SHOULD BE REMOVED Outline Dimensions AVTrON AV850 SMArTach II™ WEIGHT — 9 LBS FOr FrAMES CD180-CD6900 4 - SEE SHEET 2 FOR OTHER AVAILABLE TERMINATIONS 3 - DIMENSIONS ARE IN INCHES [MILLIMETERS] 2 - ALL DIMENSIONS ARE APPROX. 1 - WEIGHT: NOTES: DRAWING NUMBER AV850 3.83 [97.3] SHEET 1 OF 2 1.23 [31.3] OPTIONAL SHAFT GROUND Application Information 4.66 [118.4] 8.43 [214.0] 0.13 [3.2] OPTIONAL 2nd ISOLATED OUTPUT 3/16 [4.763] SQ. KEY FURNISHED COVER PLATE SINGLE OUTPUT ONLY 5.56 [141.2] 0.53 [13.5] 16° 16° Other 7.38 [187.3] Ø4.50 [114.3] Ø6.75 [171.4] 5 FT [1524.0] MIN 1/2-14 NPT LED ALARM INDICATOR OPTIONS "P","V"&"G" PLUG-IN INDUSTRIAL CONNECTOR OPTIONAL DUAL SHAFT 0.6250/0.6245 45° 45° 3/8-16 UNC x 5/8 DEEP 4 PLACES Ø [15.875/15.862] 2.06 [52.3] BOTH ENDS Terms 1.87 [47.6] Ø5.875 [Ø149.2] OPTIONS "M"&"N" 1/2" FLEXIBLE WATERPROOF CONDUIT 3.35 [85.1] 4 - SEE SHEET 2 FOR OTHER AVAILABLE TERMINATIONS 3 - DIMENSIONS ARE IN INCHES [MILLIMETERS] 2 - ALL DIMENSIONS ARE APPROX. 1 - WEIGHT: NOTES: www.gemotors.com • 800-541-7191 AVTrON AV485 SMArTach II™ WEIGHT — 11 LBS FOr FrAMES CD180-CD6900 GEP387M 09/11 • Prices and data subject to change without notice. DRAWING NUMBER AV485 4.53 Avtron Tachometer Frames 180AT to 6900 General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Motor Pricing OPTIONS "P" & "G" PLUG-IN INDUSTRIAL CONNECTOR 1.97 [50.0] 1/2-14 NPT LED ALARM INDICATOR OPTIONAL COVER FOR EXTENDED SHAFT MOTORS 8.54 [216.9] 8.03 [204.0] 8.500 8.498 [215.900] [215.849] DIA 4.38 [111.1] 8.5015 8.5035 [215.9381] [215.9889] DIA 45° 9.00 DIA [228.6] Accessories & Modifications Modifications Pricing 5.38 [136.6] 0.19 [4.8] 4.38 [111.1] 0.24 [6.1] [30.0] 1.18 8.75 [222.3] OPTIONAL ISOLATED DUAL OUTPUT 2.94 [74.7] 0.547 [13.89] DIA 4 HOLES EQUALLY SPACED ON A 7.250 [184.15] DIA Outline Dimensions STANDARD FLAT COVER SEE NOTE 4 AVTrON AV85 THIN-LINE II™ WEIGHT — 2.5 - 4 LBS FOr FrAMES CD180 - CD6900 4 - STANDARD FLAT COVER SHOWN IN FRONT VIEW. OPTIONAL THRU-SHAFT COVER NOT SHOWN. DRAWING NUMBER AV85A SHEET 1 OF 2 MAGNETORESISTIVE, NEMA 8.500 C-FACE Application Information 3.83 [97.3] HOLE FOR Ø1.122/1.125 [28.499/28.575] SHAFT 4.66 [118.4] 8.43 [214.0] 1.26 [32.1] OPTIONAL SHAFT GROUND OPTIONAL 2nd ISOLATED OUTPUT 0.53 [13.5] 7.42 [188.5] 6.75 [171.5] Other 5.56 [1 41.2] COVER PLATE SINGLE OUTPUT ONLY 16° 5 FT [1524.0] MIN 1/2-14 NPT LED ALARM INDICATOR OPTIONAL THRU SHAFT MODEL OPTIONS "P","V"&"G" PLUG-IN INDUSTRIAL CONNECTOR CUSTOMER SHAFT Terms 16° Ø5.875 [Ø149.2] 41° 41° OPTIONS "M"&"N" 1/2" FLEXIBLE WATERPROOF CONDUIT 3/8-16 UNC x 5/8 DEEP 4 PLACES 3.350 [85.1] 3.38/4.13 [85.7/104.9] STUB SHAFT EXTENSION 4.720 [119.9] 4.54 4 - SEE SHEET 2 FOR OTHER AVAILABLE TERMINATIONS 3 - DIMENSIONS ARE IN INCHES [MILLIMETERS] 2 - ALL DIMENSIONS ARE APPROX. 1 - WEIGHT: NOTES: www.gemotors.com • AVTrON AV685 SMArTach™ (HOLLOW SHAFT) WEIGHT — 14 LBS FOr FrAMES CD180 - CD6900 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Type AN Tachometer Frames 180AT to 6900 General Information Type CD For frame sizes CD180AT through CD6900, the tachometer can be mounted with condulet on right or left side, top or bottom, but will be mounted on same side as machine leads unless otherwise specified. Providing mounting conditions permit, condulet may be turned so that entrance can be made in any direction. AN-AC WEIGHT — 15 LB. From 36A180215AA OPTIONAL SECOND SENSOR MODULE Outline Dimensions 4X Ø.625 THRU ON A Ø7.250 B.C. 3.732 8.08 .400 MAGNETIC WHEEL POSITION Ø8.499 ± .001 Ø2.375 -.002 -.003 Ø8.5010 +.0015 +.0005 Application Information FLAT COVER 4.350 4X 3/8-16 X 3/4" LOW HEAD SOCKET CAP SCREW 8.08 .250 Accessories & Modifications NOTES: Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction .200 4X #10-32 X .79L HEX HEAD SCREW 2.560 Other #6-32 X 1/2" SHCS 4 PER SENSOR MODULE 2.15 4.47 1/2" NPT CONDUIT CONNECTION 8.94 DIMENSIONS IN INCHES Single Dual NORTHSTAR RIM Tach RT8 PPr A B C D A B C D 240 12.22 7.64 7.11 — 15.28 7.64 7.11 14.21 600 12.78 8.21 7.67 — 16.41 8.21 7.67 15.34 DRAWING NUMBER 702998-0001 19OCT2011 Terms Output NOrTHSTAr rIM Tach® rT8 AN-DG WEIGHT — 15 LB. From L79202-1 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.55 Northstar Tachometer DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD Application Information Outline Dimensions NOrTHSTAr rIM Tach® 6200 WEIGHT 27 LB. FrAME CD180AT-CD6900 Terms Other NOrTHSTAr SL85 FrAMES CD180AT-CD500AT 4.56 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Northstar Tachometer Frames CD180 to CD6900 General Information Type CD Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Terms Other Application Information Outline Dimensions NOrTHSTAr rIM Tach® 1250 FOr CD6000 FrAMES ONLY NOrTHSTAr SLIM Tach® HS56 HOLLOW SHAFT ENCODEr FOr FrAMES CD180 - CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.57 Dynapar Encoder Frames CD180 to CD6900 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction 10-32 CLAMP SCREW TORQUE TO 50 - 55 IN/LBS WITH LOCTITE ON THREADS Motor Pricing General Information Type CD 2X Ø0.6228 +.002/-.000 .86 [21.84] 3.36 [85.34] 3X 10-32 UNC-2B (X) .19 DEEP ON DIA. 3.000 BOLT CIRCLE 120° 3X ø 2.50 [63.50] Modifications Pricing 2.25 [57.15] .06 [1.52] 1.95 [49.53] 1.25 ø[31.75] .57 [14.48] ø 2.50 [63.45] PILOT SHOWN WITH 10 PIN CONNECTOR ø 3.80 [96.52] Accessories & Modifications FOR REFERENCE DYNAPAr HA625 ENCODEr FOr FrAMES CD180 - CD6900 DYNAPAr HS35r ENCODEr HOLLOW SHAFT — WEIGHT 16 OZ Dynapar Encoder FOr FrAMES CD180HS35R - CD6900 Outline Dimensions DWG. NO. 702990-0001 09-27-11 Terms Other Application Information DATE DYNAPAr X25 ENCODEr EXPLOSIONPrOOF WEIGHT — 4.5 LBS FOr FrAMES CD180 - CD6900 4.58 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 3.000 [76.20] Dynapar rotopulse Frames 180AT to 6900 General Information Type CD Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Terms Other Application Information DYNAPAr H56 rOTOPULSEr WEIGHT — 9 LBS FOr FrAMES CD180 - CD6900 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.59 eXcellon® Type BC Tachometer Frames 180AT to 6900 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD From 36A180215AB Terms Other Application Information Outline Dimensions FOr FrAMES CD180AT-CD6900 BC42 WEIGHT — 35 LB. FOr FrAMES CD180AT-CD6900 BC46 WEIGHT — 45 LB. 4.60 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. From 36A180215AC eXcellon® Form Y Tachometer Frames 180AT to 6900 General Information Type CD DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Type XA XB 5PY59EY 5.06 9.02 5PY59JY 6.50 10.46 Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing Model 5PY59EY is an AC tachometer generator for speed-indicating duty. Model 5PY59JY is a DC tachometer generator for speed-regulating and/or speed-indicating duty. Terms Other FOr FrAMES CD180AT-CD6900 FOrM Y WEIGHT — 25 LB. From 36A180215AD www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.61 Sliding Base Horizontal Floor Mounting Only Frames 180AT to 500AT DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD Approx. Net Wt. in Lbs. BB E F AL AM AO Ar AT AU AX BT XH XC CD182AT 9.00 6.500 3.75 2.25 12.75 9.5000 4.50 4.250 0.1340 0.500 1.50 3.00 0.375 X 1.50 1.2500 CD186AT 11.0 9.000 3.75 3.50 12.75 12.000 4.50 5.500 0.1340 0.500 1.50 3.00 0.375 X 1.50 1.2500 CD189AT 14.0 12.00 3.75 5.00 12.75 15.000 4.50 7.000 0.1340 0.500 1.50 3.00 0.375 X 1.50 1.2500 CD218AT 17.0 12.00 4.25 5.00 15.00 15.500 5.25 7.000 0.1640 0.500 1.75 3.50 0.375 X 1.50 1.2500 CD219AT 21.5 13.00 4.25 5.50 15.00 16.500 5.25 7.500 0.1640 0.500 1.75 3.50 0.375 X 1.50 1.2500 CD2110AT 19.0 14.50 4.25 6.25 15.00 18.000 5.25 8.250 0.1640 0.500 1.75 3.50 0.375 X 1.50 1.2500 CD258AT 20.0 15.00 5.00 6.25 17.75 19.375 6.25 8.750 0.1875 0.625 2.00 4.00 0.500 X 1.75 1.4375 CD259AT 21.0 16.50 5.00 7.00 17.75 20.875 6.25 9.500 0.1875 0.625 2.00 4.00 0.500 X 1.75 1.4375 CD287AT 24.0 15.50 5.00 6.25 19.75 19.875 7.00 9.000 0.1875 0.625 2.00 4.50 0.500 X 2.00 1.6875 CD288AT 24.0 17.00 5.50 7.00 19.75 21.375 7.00 9.750 0.1875 0.625 2.00 4.50 0.500 X 2.00 1.6875 CD327AT 34.0 17.50 6.25 7.00 22.75 22.750 8.00 10.25 0.1875 0.750 2.50 5.25 0.625 X 2.50 2.1875 CD328AT 35.0 19.50 6.25 8.00 22.75 24.750 8.00 11.25 0.1875 0.750 2.50 5.25 0.625 X 2.50 2.1875 CD329AT 36.0 21.50 6.25 9.00 22.75 26.750 8.00 12.25 0.1875 0.750 2.50 5.25 0.625 X 2.50 2.1875 CD365AT* 45.0 16.50 7.00 6.12 25.50 21.500 9.00 9.620 0.2500 0.880 2.50 6.00 0.750 X 3.00 2.5000 CD366AT* 50.0 18.25 7.00 7.00 25.50 23.250 9.00 10.50 0.2500 0.880 2.50 6.00 0.750 X 3.00 2.5000 CD368AT* 60.0 22.25 7.00 9.00 25.50 27.250 9.00 12.50 0.2500 0.880 2.50 6.00 0.750 X 3.00 2.5000 CD407AT* 64.0 22.25 8.00 9.00 28.75 28.125 10.0 12.75 0.2500 1.000 3.00 7.00 0.875 X 3.50 3.0000 CD409AT* 70.0 26.25 8.00 11.0 28.75 32.125 10.0 14.75 0.2500 1.000 3.00 7.00 0.875 X 3.50 3.0000 CD504AT* 132 20.75 10.0 8.00 35.00 28.000 12.5 12.50 0.3125 1.250 3.50 8.00 1.125 X 3.50 3.0000 CD506AT* 138 24.75 10.0 10.0 35.00 32.000 12.5 14.50 0.3125 1.250 3.50 8.00 1.125 X 3.50 3.0000 CD508AT* 146 29.75 10.0 12.5 35.00 37.000 12.5 17.00 0.3125 1.250 3.50 8.00 1.125 X 3.50 3.0000 Other Application Information Outline Dimensions Frame DIMENSIONS IN INCHES Terms *These frames have two adjusting screws and eight gussets shown in phantom. From 533C230AC 4.62 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Soleplates Frames CD210AT to CD500AT General Information Type CD C D E F G H J K L M CD218AT 1.62 13.25 OMIT 15.00 3 0.88 8.50 11.5 0.56 0.88 6.230 1.5 CD219AT 1.62 14.25 OMIT 16.00 3 0.88 8.50 11.5 0.56 0.88 6.230 1.5 CD2110AT 1.62 15.75 OMIT 17.50 3 0.88 8.50 11.5 0.56 0.88 6.230 1.5 CD258AT 2.00 16.50 OMIT 18.50 4 1.12 10.0 14.0 0.69 1.00 7.470 2.0 CD259AT 2.00 18.00 OMIT 20.00 4 1.12 10.0 14.0 0.69 1.00 7.470 2.0 CD287AT 2.00 16.50 OMIT 18.50 4 1.12 11.0 15.0 0.69 1.00 8.220 2.0 CD288AT 2.00 18.00 OMIT 20.00 4 1.12 11.0 15.0 0.69 1.00 8.220 2.0 CD327AT 2.25 18.50 OMIT 21.00 4 1.38 12.5 16.5 0.81 1.25 9.480 2.0 CD328AT 2.25 20.50 OMIT 23.00 4 1.38 12.5 16.5 0.81 1.25 9.480 2.0 CD329AT 2.25 22.50 OMIT 25.00 4 1.38 12.5 16.5 0.81 1.25 9.480 2.0 CD365AT 2.25 16.75 OMIT 19.75 5 1.38 14.0 19.0 1.00 1.50 10.48 2.5 CD366AT 2.25 18.50 OMIT 21.50 5 1.38 14.0 19.0 1.00 1.50 10.48 2.5 CD368AT 2.25 22.50 7 25.50 5 1.38 14.0 19.0 1.00 1.50 10.48 2.5 CD3610AT 2.25 26.50 7 29.50 5 1.38 14.0 19.0 1.00 1.50 10.48 2.5 CD2612AT 2.25 32.50 7 35.50 5 1.38 14.0 19.0 1.00 1.50 10.48 2.5 CD407AT 2.75 23.50 8 26.75 6 1.88 16.0 22.0 1.12 1.62 11.98 3.0 CD409AT 2.75 27.50 8 30.75 6 1.88 16.0 22.0 1.12 1.62 11.98 3.0 CD4012AT 2.75 37.50 8 40.75 6 1.88 16.0 22.0 1.12 1.62 11.98 3.0 CD504AT 3.25 22.50 8 26.50 6 1.88 20.0 26.0 1.38 2.00 14.48 3.0 CD506AT 3.25 26.50 9 30.50 6 1.88 20.0 26.0 1.38 2.00 14.48 3.0 CD508AT 3.25 31.50 9 35.50 6 1.88 20.0 26.0 1.38 2.00 14.48 3.0 CD5010AY 3.25 38.50 9 42.50 6 1.88 20.0 26.0 1.38 2.00 14.48 3.0 Terms NOTE: Motors are shipped with sole plates bolted to motor feet. Shims are included. Motor and sole plates will be installed as a unit. Sole plates will not be removed from motor and installed separately. Outline Dimensions B Application Information A Other DIMENSIONS IN INCHES Frame Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction From 36A167263CA www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.63 Soleplates Frames CD6050 to CD6280 DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Frame Approx. Net Wt. in Lbs. XA XB XC XD XE XF XG CD6050 412 48.0 52.0 7 2.00 30 35 16.62 16.62 CD6052 428 50.0 54.0 7 2.00 30 35 CD6054, 6055 444 52.0 56.0 7 2.00 30 35 16.62 CD6057 460 54.0 58.0 7 2.00 30 35 16.62 CD6058, 6059 476 56.0 60.0 7 2.00 30 35 16.62 CD6062. 6063 508 60.0 64.0 7 2.00 30 35 16.62 CD6066 539 64.0 68.0 7 2.00 30 35 16.62 19.12 CD6154 444 52.0 56.0 7 2.00 35 40 CD6157 460 54.0 58.0 7 2.00 35 40 19.12 CD6160 476 58.0 62.0 7 2.00 35 40 19.12 CD6163 508 60.0 64.0 7 2.00 35 40 19.12 CD6164 523 62.0 66.0 7 2.00 35 40 19.12 19.12 CD6165 539 64.0 68.0 7 2.00 35 40 CD6168, 6169 555 66.0 70.0 7 2.00 35 40 19.12 CD6173 587 70.0 74.0 7 2.00 35 40 19.12 CD6177 626 75.0 79.0 7 2.00 35 40 19.12 CD6259 617 56.5 60.5 8 2.25 42 47 23.37 CD6262 647 59.5 63.5 8 2.25 42 47 23.37 CD6266, 6268 703 65.0 69.0 8 2.25 42 47 23.37 CD6270, 6271 739 68.5 72.5 8 2.25 42 47 23.37 CD6275 780 72.5 76.5 8 2.25 42 47 23.37 CD6280 831 77.5 81.5 8 2.25 42 47 23.37 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD 4.64 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Soleplates Frames CD6766 to CD6999 General Information Type CD XC XD XE XF XG XH XJ XK 64.60 68.620 7.500 32.9 42.46 45.46 27.12 21.7 4.50 7.75 CD6770 876.0 68.10 72.120 7.500 36.4 42.46 45.46 27.12 21.7 4.50 7.75 CD6771 886.0 66.90 72.940 7.500 32.9 42.46 45.46 27.12 21.7 4.50 7.75 CD6774 924.0 72.10 76.120 7.500 40.4 42.46 45.46 27.12 21.7 4.50 7.75 CD6776 926.0 72.40 76.440 7.500 36.4 42.46 45.46 27.12 21.7 4.50 7.75 CD6778 974.0 76.40 80.440 7.500 40.4 42.46 45.46 27.12 21.7 4.50 7.75 CD6779 982.0 77.10 81.120 7.500 45.4 42.46 45.46 27.12 21.7 4.50 7.75 CD6785 1034 81.40 85.440 7.500 45.4 42.46 45.46 27.12 21.7 4.50 7.75 CD6873 1466 71.22 75.250 12.00 42.5 54.20 57.20 30.12 27.0 9.00 8.30 CD6876 1542 75.22 79.250 12.00 46.5 54.20 57.20 30.12 27.0 9.00 8.30 CD6881 1628 79.72 83.750 12.00 51.0 54.20 57.20 30.12 27.0 9.00 8.30 CD6882 1630 79.82 83.810 12.00 42.5 54.20 57.20 30.12 27.0 9.00 8.30 CD6885 1706 83.82 87.810 12.00 46.5 54.20 57.20 30.12 27.0 9.00 8.30 CD6887 1732 85.22 89.250 12.00 56.5 54.20 57.20 30.12 27.0 9.00 8.30 CD6890 1792 88.32 92.310 12.00 51.0 54.20 57.20 30.12 27.0 9.00 8.30 CD6896 1896 93.82 97.810 12.00 56.5 54.20 57.20 30.12 27.0 9.00 8.30 CD6977 1594 76.60 80.620 12.25 44.2 54.20 68.98 35.12 27.5 9.25 8.25 CD6981 1672 80.60 84.620 12.25 48.2 65.98 68.98 35.12 27.5 9.25 8.25 CD6985 1768 85.60 89.620 12.25 53.2 65.98 68.98 35.12 27.5 9.25 8.25 CD6986 1760 85.20 89.180 12.25 44.2 65.98 68.98 35.12 27.5 9.25 8.25 CD6990 1836 89.20 93.180 12.25 48.2 65.98 68.98 35.12 27.5 9.25 8.25 CD6991 1894 92.10 96.120 12.25 59.7 65.98 68.98 35.12 27.5 9.25 8.25 CD6996 1934 94.20 98.180 12.25 53.2 65.98 68.98 35.12 27.5 9.25 8.25 CD6999 2060 100.7 104.68 12.25 59.7 65.98 68.98 35.12 27.5 9.25 8.25 Outline Dimensions XB 834.0 Application Information XA CD6766 Other Approx. Net Wt. in Lbs. Terms Frame Accessories & Modifications Modifications Pricing Motor Pricing DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 4.65 NEMA Mounting Configurations DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Type CD 4.66 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Application Information Page Air Flow Requirements for Separately Ventilated Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.13 General Information Index Bearing Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Bearing Life Factor vs. Speed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 Bearing Life (L10) Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8 Bearing Life Speed vs. Load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7 Blower Data for Blower Ventilated Motors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.14 Blower Data for TEAAC and TEWAC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.15 Direction of Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Environmental Effect on Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Environmental Effects on Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 Maximum Momentary Overload. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Motor Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Motor Load Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.16 Modifications Pricing Audio Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.10 Accessories & Modifications Armature Current, Rate of Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Outline Dimensions Ambient Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Motor Pricing Air Supply Quality Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 Pinion Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.10 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Special Load Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 Application Information Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Speed Variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Standard Constant Torque Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Other Speed Range by Armature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Standard Field Voltages and Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Thrust Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 V-Belt Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 5.1 Terms Starting Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Application Information General Information CD180AT-CD6900 Frames General Information Safety All motors are furnished with reconnectable fields as listed in the tabulation below: The material in this publication should be used with due regard to the hazards to personnel resulting from the use and application of electric motors and generators. Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing STAnDArD FIelD VOlTAGeS AnD COnneCTIOnS Field Voltage reconnectable Field Voltage When Connected 1 Circuit (Series) Field Voltage When Connected 2 Circuit (Parallel) 500 or 240 300/150 240/120 300 240 150 120 180 200/100 200 100 Armature Voltage Speed Vibration • ±7.5% at rated armature voltage and field current • Not to exceed 15% full load (cold) to full load (hot) — ventilated • Not to exceed 20% full load (cold) to full load (hot) — totally enclosed It is strongly recommended that the user become familiar with the NEMA publication MG2, “Safety Standard for Construction and Guide for the Selection, Installation, and Use of Electric Motors and Generators.” electrical Shocks Higher direct current motor voltages are now common due to the use of rectified AC power supplies, and the danger of shock is substantially increased. Rectified 460 (RMS) AC volt power results in about 500 or more volts DC. Overall safety can be improved by: Miscellaneous • Torque = HP x 5252 Base Speed • Air Rise = Air exhaust temperature minus air intake temperature in degrees C (25 degrees C is considered high) 1. Specifying that frames of rotating machines be solidly grounded in accordance with the National Electrical Starting Current Code and consistent with sound local practices. Standard motors permit 250% full load current for momenBecause paint insulates, foot or flange bolts cannot be tary starting duty on frames CDL182AT-CD5010AY and 300% counted on to provide a satisfactory ground. Standard on frames CD6000-CD6900. motors are provided with a brass screw and symbol inside or adjacent to the conduit box. Application Information Maximum Momentary Overload Standard continuously rated motors rated 3/4 HP per RPM and less will carry 150% full load current for a period of one minute throughout the rated speed range and are suitable for higher current peaks below rated top speed. (Refer to page __ of this publication.) Other Motor Fields Terms Personnel Protection Consideration should be given to the type of personnel who would normally come in close contact with motors and generators. Equipment installed in locations open to the general public should be better protected than those located in areas available only to qualified personnel, who should recognize any potential hazard involved in the use of the equipment. Standard motors in frames CDL182AT-CD5010AY and all ratings in the CD6000-CD6900 frames are shunt wound. rate of Change of Armature Current Motors in frames CD6000-CD6200 are suitable for a rate of change of armature current of 11 per unit per second. Motors in frames CD6700-CD6900 are suitable for 22 per unit per second change in armature current. Contact GE for information if higher rates are needed. 5.2 www.gemotors.com • 800-541-7191 2. Specifying a dripproof fully guarded enclosure as a minimum. This will decrease the danger to personnel from contact with the brush rigging and commutator. 3. Specifying manual reset for overcurrent and overtemperature protection. Automatic reset allows resetting at an unsafe time. 4. Specifying circuitry as far as possible, which prevents access to live motor parts, unless power is removed from the armature and main field. For silicon-controlled rectified drives, the AC lines into the rectifier should be opened before maintenance work is performed on the motor. Mechanical Protection Mechanical hazards to personnel occur due to overspeed, exposure to rotating parts, mechanical overloading of shafts or bearings, and failure of lifting devices. GE motors are designed so that, in an emergency, they will withstand an overspeed in accordance with the table on the following page: GEP387M 09/11 • Prices and data subject to change without notice. Application Information All DC motors may be subject to potentially dangerous overspeeding under certain conditions of misoperation. Overspeeding of a DC compound wound or shunt wound motor may occur if the shunt field circuit becomes de-energized. Care should be exercised in the selection of couplings, belts, or pinions with due consideration given to shock loads, overloads, and pulley pitch diameters. See page 5.7 for bearing life and allowable shaft loading. Too small a pulley diameter will require excessive belt tension to prevent belt slippage. This, in turn, overloads the bearings and shafts which may result in bearing and/or shaft failure, and possible overspeeding of the motor. Motor enclosure Standard Constant Torque Self-Ventilated 60% of base speed Blower Ventilated 5% Additional coverage of the hazards in handling the rotating equipment covered in this publication may be found in the instruction books sent out with the equipment. Separately Ventilated 5% Hazards Due To environment Motors which operate in explosive atmospheres must meet the requirements of Articles 501-8 or 502-8 of the National Electrical Code. The Code assigns authority to approve the installation to “the authority having jurisdiction” (see Article 100 — Definitions of the NEC). TEWAC 5% www.gemotors.com • 800-541-7191 60% TEAO 40% TEAAC 5% Motors ventilated from a separate source are supplied with a constant flow of cooling air, which is independent of the motor operating speed. A constant supply of cooling air permits much lower speed operation of a separately ventilated motor at rated torque without exceeding a maximum allowable temperature rise. Other 5% TEFC Continued operation at high temperature will significantly reduce insulation life. However, generally most applications have compensating periods of operation at some temperature lower than normal so that the use of the higher current for many applications is justified. Terms Motors approved by U.L. for Class I, Group D or Class II, Groups E, F, and G are available in some ratings. However, it is the responsibility of the customer to be familiar with the NEC and the local jurisdictional requirements and to determine that the motor selection (including possibly permissible alternatives to U.L. approved motors) is “acceptable to the authority having jurisdiction.” TENV Motor Pricing At low operating speeds, the flow of ventilating air passing through the machine is reduced resulting in a decreased heat dissipation rate. Consequently, it becomes necessary to analyze the motor thermal capacities at each speed and load condition. In general, motors of dripproof fully guarded, self-ventilated, and totally enclosed fan cooled enclosures must be operated above 60% of the motor base speed to ensure proper cooling. Not greater than 50 percent above full load base speed. Modifications Pricing Specifications should require that guards be placed over exposed couplings, pulleys, pinions, and unused shaft extensions for the protection of the operating personnel. Compound with speed regulation of 35 percent or less Accessories & Modifications Motor Heating Cooling air for dripproof fully guarded self-ventilated, and totally enclosed fan cooled direct current motors is provided by shaft-driven fans. Shunt Outline Dimensions Motors can overspeed due to improper wiring during installation. GE installation and instruction books contain statements and instructions to guard against such overspeed due to wrong initial connections. Maximum Monetary Overspeed 25 percent above the maximum nameplate speed or 15 percent above the corresponding no-load speed, whichever is greater. Application Information Unless the speed is inherently limited by the application of the motor, DC motors should be protected against dangerous overspeed by overspeed devices, field loss relays, or other means. Insulation Insulation life is dependent on many factors. Insulation failure results from either chemical or mechanical degradation or a combination of both. Chemical degradation is a function of the time and temperature at which the insulation is operated relative to its temperature rating. Roughly, a machine operated at the nominal temperature rating will operate twice as long as a machine operated 10°C higher. Chemical degradation can also be accelerated, if the machine operates in dirty or chemical atmospheres or in atmospheres of high moisture content. Mechanical degradation occurs when the conductors are subject to high forces. These forces may cause coil movement, which eventually can abrade the turn insulation on the wire or break the ground insulation. Type of Motor General Information CD180AT-CD6900 Frames GEP387M 09/11 • Prices and data subject to change without notice. 5.3 Application Information The exciting fields on all continuously rated, dripproof fully guarded blower ventilated and separately ventilated, and totally enclosed nonventilated motors are designed for continuous excitation at field voltages up to 105% of the rated value while the motor is operating at any speed and load within the capability of the armature. Temperatures under these conditions will not exceed maximum allowable. However, insulation life will be shortened, particularly during prolonged operation at low speed. CAUTIOn: Motor Field Heating — Unless specifically ordered, motors are NOT capable of continuous standstill excitation at rated field current. When the motor is shut down for more than 15 minutes, one of the following options must be used: Modifications Pricing Motor Pricing General Information CD180AT-CD6900 Frames Terms Other Application Information Outline Dimensions Accessories & Modifications 1. De-energize the field completely 2. Use field economy relays to limit the field current to a maximum of 50% of the nameplate rating 3. When applicable, fields may remain fully energized if the motor ventilation system (blower or customer duct) remains in operation. environmental effects On Insulation The insulation system used on GE DC motors is adequate for use in humid atmospheres. Acids, alkalies, abrasive dust, conducting dust, etc., when present, impose a severe hardship on the insulation system. Special consideration is required to determine the acceptability of a dripproof fully guarded enclosure, since the contamination itself may conduct shorting or grounding current over the insulation. This current gradually develops a permanent creepage path which can cause failure. The exposed uninsulated circuits on DC machines, such as the commutator brush rigging and bolted connections, allow early electrical failure when the enclosure is inadequate, regardless of the insulation system. Extra varnish dips will not correct this problem. An adequate enclosure should be used. Where contamination is expected, a study of the history of the application should be made to determine what degree of protection has been successful in the past. A standard dripproof fully guarded machine can often be applied successfully, but a totally enclosed machine will provide extra reliability. 5.4 www.gemotors.com • 800-541-7191 Air Supply Quality Guidelines Cooling air quality can have an effect on machine performance. Nonconducting contaminants such as cement dust, dirt, sand, and sawdust can promote overtemperature by restricting cooling passages and air circulation. Abrasive materials may erode insulations within the machine. Conductive contaminants such as carbon dust, metal particles, and salt can also provide shorting paths to ground. Periodic “blowing out” or vacuuming of dust accumulation will tend to avoid major problems if oil, grease, or other liquids are allowed to enter the machine, contaminants will “stick” to insulating surfaces and make effective cleaning difficult. Corrosive gases in applications such as papermills can have an extreme effect on machine performance and service life. Chlorine, hydrogen sulfide, and sulphur dioxide can damage commutator copper, hardware, and varnish systems. On the commutator, severe contamination will cause unprotected copper (where the brushes don’t contact) to oxidize and turn bluish-gray developing scale that can bridge across insulating mica and cause commutation distress and possibly a flashover. Contamination produces high friction and uneven film which reduces brush life. Sparking may result from poor, uneven, or non-conductive commutator film which can lead to bar etching and further commutator surface erosion. If high corrosion is suspect, air sampling coupons can be placed in the cooling air to determine corrosion rates. Field experience has shown that corrosion rates of motor cooling air should be below .5 microns/year to limit corrosion damage effects. Air sampling coupons and analysis are commercially available. Periodic seater stone application can prevent buildup and uneven commutator filming. With high corrosion evident, further analysis can pinpoint the type of gases present. Elimination of high levels of gas can be made by relocating air inlets to other rooms or areas or simply raising an inlet off of a wet floor or away from open gutter-type drains. Additional filtering means such as charcoal filters can further improve air quality. effects of radiation Radiation can cause insulation degradation, if present in sufficient amounts. Where motors are exposed to the more common types of atomic radiation, nearly all standard insulations may be used if the radiation is below 107 Roentgens. Where radiation exceeds this value, specific information should be included in the requisition, proposition, or specifications. GEP387M 09/11 • Prices and data subject to change without notice. Application Information Bearing life Direction of rotation Motors in frame sizes CDL182AT-CD5010AY are suitable for continuous rotation in either direction or for reversing duty. Motors in frame sizes CD6000-CD6900 are suitable for continuous operation in the rotation specified on the nameplate for reversing duty. Motors in all frame sizes are generally suitable for continuous rotation in either direction or for reversing duty. In frame sizes CD6000-CD6900 applications in contaminated environments require that brushes be trailing for the desired rotation. If not, they may experience rapid brush wear during continuous operation with the brushes stubbing. Performance Kinamatic motors meet NEMA standards for industrial equipment. regulation — See NEMA Standards. Bearing life for belted drives is determined by calculating the radial load at the end of the shaft. The radial load, W, produced by the belts when tightened just enough to transmit the load without slipping is given by the relation: ( HP ) ( RPM ) (K , lbs) W = 126,000 D b Where: D = Sheave pitch diameter in inches for V-belt application. HP = Maximum ratio of horsepower, including overloads, RPM to the minimum speed at which that power occurs. Kb = Belt tension factor from table below: BelT TenSIOn FACTOr, Kb Kb Description 1.0 Chain and Sprocket Drive 1.2 Timing Belt 1.5 V-Belt, 1:1 Ratio 1.8 V-Belt, 2:1 Speed Decreased Ratio 2.0 Flat Belts Other Standard Kinamatic™ dripproof fully guarded and totally enclosed motors are designed for operation in a 40°C ambient temperature and at altitudes up to 3,300 feet above sea level. excitation — See modification pages or notes on price pages The curves which follow can be used to determine the L10 for standard shunt field voltages. life, which is the life in hours that 90% of bearings with this Parallel Operation — Where motors are to be operated in load would be expected to exceed without failure. The electrical and mechanical parallel, refer to GE. standard ball bearing and standard shaft option will be the most economical, if acceptable life is obtained from the curve. A commonly used design figure is 20,000 hours. www.gemotors.com • 800-541-7191 Motor Pricing Ambient Conditions Modifications Pricing The standard NEMA shaft extension is designed for belted loads. Dimensions are provided on the standard dimension sheets. A sliding base is available as an accessory to facilitate belt adjustment. Accessories & Modifications Standard motors are suitable for reduced speed operation by adjustable armature voltage. Some torque derating may be necessary for applications requiring extended periods of low-speed operation. For specific duty cycles contact GE. WArnInG: The presence of silicone in DC Motors, particularly totally enclosed constructions, will cause rapid brush wear. Sources of silicone include oils, RTV compounds, mold release agents, and some insulating varnishes. These silicone substances must be avoided to ensure proper DC motor performance. Outline Dimensions Speed range By Armature Control The V-belt system produces a heavy shaft and bearing loading, making it necessary that these factors be considered carefully for proper application. Since belt drives impose a bending moment on the motor shaft, it is always desirable to have the motor sheave located as close to the motor bearing as possible to minimize both bearing load and shaft stress. This will result in increased bearing life. The bearing life curves that follow assume the load is centered at the end of the shaft. Improved V-belts can significantly reduce the number and size of belts required for a given load. These new belts should always be considered, since the sheave will be shorter and the load centered closer to the bearing. Brush Wear Caused by Silicone Application Information V-Belt Drives GEP387M 09/11 • Prices and data subject to change without notice. 5.5 Terms environmental effects On Brushes General Information CD180AT-CD6900 Frames Application Information Belt tension should be checked and adjusted following the belt manufacturer’s recommendations. 3.0 2.0 1.5 1.0 .9 .8 .7 .6 .5 .4 Mounting may be either horizontal or vertical for these bearing life determinations as long as no axial load other than the weight of the armature is present if vertical. Terms Other Special load Considerations Where the load is overhung beyond the motor shaft extension or greater life is desired, the application should be referred to GE. Pinion Drives While Kinamatic motors are not designed for overhung pinion drives, they may be successfully applied under suitable conditions. In addition to a radial load, some gears produce thrust load on the bearing. Vibrations, particularly of the torsional variety, are limiting on some spur or straight bevel gear applications. Complete details of the proposed gearing should be referred to GE in all cases. 5.6 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 5000 Matched belts run smoother, look better, and last longer. Longer belt life results if the belts and sheaves are kept clean and the belts are prevented from rubbing against the belt guards or other obstructions. 4000 AVERAGE RPM 3000 2000 1000 There is normally a drop in tension during the first 24 to 48 hours of operation. During this “run in” period, the belts seat themselves in the sheave grooves and initial stretch is removed. Belt tension should be re-checked after a day or two of operation. Bearing life Factor vs. Speed L10 LIFE FACTOR If slippage occurs after the belt tension has been correctly adjusted, the belts and pulleys have not been chosen properly for the job. Due to the mounting position or type of drive arrangement, a thrust load may be applied to the motor shaft. The Kinamatic motor is designed to permit a limited amount of thrust load. This permissible load will vary by mounting position and direction of the load due to the weight of the armature. 700 Outline Dimensions It is important to know that bearing life for V-belt applications is independent of the motor load. Once the belts have been tightened just enough to prevent slipping when the maximum torque is being delivered by the motor, the radial load, W, on the shaft and bearing is there and remains constant regardless of the motor load. For timing belts and chain drives, the radial load, W, does vary somewhat with motor load and so the motor load duty cycle, as well as the average speed should be considered to estimate bearing life. Thrust loads 500 Application Information However, applications with a calculated life of as low as 5,000 hours have sometimes been necessary to limit belt speeds to 6,000 feet per minute. The curves are drawn for 1750 RPM average speed. If the application has some other average speed, the life can be adjusted by multiplying by the bearing life factor curve. (See curve on right) 300 Accessories & Modifications Modifications Pricing Motor Pricing General Information CD180AT-CD6900 Frames General Information Application Information BeArInG lIFe AT 1150 rPM AVerAGe SPeeD VS. lOAD, W 1150 (For other Average Speeds, multiply life by AVG. SPD. ) Frame Sizes CD6000-CD6200 6000 5600 5000 5300 6200 ROLLER 6100 ROLLER 4000 2000 Modifications Pricing 6100, 6200 ROLLER 6000 ROLLER 3000 1800 1500 1500 1700 1000 Accessories & Modifications 6100 BALL 6000 BALL 800 6200 BALL 600 Outline Dimensions 400 200 Application Information 100000 10000 1000 BEARING LIFE AT 1150 RPM AVERAGE SPEED Vs. LOAD, W 1150 (For other average speeds, multiply Life by avg spd ) Frame Sizes CD6000 - CD6200 Other 100 Terms MAXIMUM RADIAL LOAD, W., AT END OF SHAFT (LBS.) 7500 Motor Pricing 10000 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 5.7 General Information Application Information BeArInG lIFe AT 1750 rPM AVerAGe SPeeD VS. lOAD, W 1750 (For other Average Speeds, multiply life by life AVG. SPD. ) 10000 MAXIMUM RADIAL LOAD, W., AT END OF SHAFT (LBS.) 5000 4000 3000 2630 2000 1670 1500 1340 1000 1000 900 800 700 FRAME CD500AT 750 550 600 CD400AT CD360AT 500 400 390 300 280 CD320AT CD287AT, CD288AT CD258AT, CD259AT CD210AT 200 CD180AT 10000 MAXIMUM RADIAL LOAD, W., AT END OF SHAFT (LBS.) OVerSIze BAll BeArInG AnD OVerSIze SHAFT 5000 5000 4000 3500 3000 2000 2000 1670 1500 1340 FRAME CD5010AY 1000 900 800 700 CD500AT CD400AT 600 CD360AT CD320AT 500 400 300 200 www.gemotors.com • 800-541-7191 100000 90000 80000 70000 60000 5.8 50000 L10 BEARING LIFE (HOURS) 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 100 1000 Terms Other Application Information Outline Dimensions L10 BEARING LIFE (HOURS) 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 100 1000 Accessories & Modifications Modifications Pricing Motor Pricing STAnDArD BAll BeArInG AnD STAnDArD SHAFT GEP387M 09/11 • Prices and data subject to change without notice. General Information Application Information Motor Pricing STAnDArD SIze rOller BeArInG AnD STAnDArD SHAFT 5000 4000 3000 3000 2000 1600 FRAME CD500AT 1100 1000 900 800 700 Modifications Pricing 1500 CD360AT & CD400AT 600 500 CD320AT 400 Accessories & Modifications 300 200 L10 BEARING LIFE (HOURS) 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 100 Outline Dimensions MAXIMUM RADIAL LOAD, W., AT END OF SHAFT (LBS.) 10000 10000 5000 5000 4000 3000 2500 FRAME CD5010AY 2100 1800 2000 Application Information 3500 FRAME CD500AT 1500 CD400AT CD360AT CD320AT 1000 900 800 700 Other 600 500 400 300 200 • 800-541-7191 100000 90000 80000 70000 60000 www.gemotors.com 50000 L10 BEARING LIFE (HOURS) 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 100 Terms MAXIMUM RADIAL LOAD, W., AT END OF SHAFT (LBS.) OVerSIze rOller BeArInG AnD OVerSIze SHAFT GEP387M 09/11 • Prices and data subject to change without notice. 5.9 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Application Information Power Supplies is manufacturers’ data taken under controlled conditions. When DC motors are operated from rectified power supplies, This data is generally taken at no load, at a specific distance from the source, and is measured in dB’s of sound pressure the pulsating voltage and current wave forms affect the with a reference pressure of 0.00002 N/m2. Another motor performance by increasing motor heating and measure of the intensity of the noise which is becoming degrading commutating. Because of these effects, it is necessary that the motors be designed or specially selected more accepted is sound power. This is a measure of the intensity of the noise at its source. It is arrived at to suit this type of operation. mathematically through an array of sound pressure A motor may, under some conditions, be operated from a readings. The units of sound power are also dB’s with a power supply different from that indicated on the nameplate. reference power of 1012 watts. This number is the noise level Because the three letters used to identify power supplies in of the source and is independent of the surroundings. It can common use have been chosen in alphabetical order of be used to predict resulting sound pressure levels. increasing magnitude of ripple current, a motor rated on the Often, in talking of sound pressure, weighting networks will basis of an “E” power supply may be operated from a “C” or be specified. These are sound pressure readings with certain “D” power supply, and a motor rated on the basis of “D” power supply may be operated from an “C” power supply but frequencies omitted to more nearly match the frequency response of the human ear (e.g. “A” network). While “A” not necessarily from an “E” power supply. If it is desired to network dB levels may be the same for two noise sources, it use a motor rated on the basis of a “C” power supply on is important to realize that they may sound very different to either a “D” or “E” power supply, it may be necessary to add the ear. The ear is much more sensitive to dB levels of a an inductance externally to the motor, in order to limit the narrow frequency range. Discreet frequency sources may ripple current to the magnitude implied in the rating. For be objectionable, even though the overall “A” network dB more information see page 2.XX (previously page 62) or level is moderate. contact GE. Typical values for the Kinamatic line of DP and TEFC frame The nameplates of DC motors intended for operation from rectified power supplies will be stamped with a Power Supply diameters are given on the following pages. For guaranteed values, refer to GE. The values are in sound power and are no Identification as described under POWER SUPPLY IDENTIFIload readings taken using MG set power. (Noise levels at full CATION and the external reactance required, if necessary. load are essentially the same as no load for MG set power.) Audio noise To estimate the average sound pressure, “A” network at Noise, by definition, is unwanted sound as is, therefore, a some distance from the machine, use the curve on the form of air pollution which must be kept under control. The following page to obtain the ∆dB to subtract from the sound occupational noise exposure standard promulgated by the power value. Occupational Safety and Health Administration (OSHA) states Blower ventilated motors will generally be quieter than that “protection against the effects of noise exposure shall self-ventilated motors. be provided when the sound levels exceed those shown in Adding one noise source equal to an existing noise source table G-16 of the OSHA standard, when measured on the A increases the total sound level 3dB. scale of a standard sound level meter at slow response.” It is Although the rectified magnetic noise levels for frames important to note that this standard applies to the working CD210AT-CD320AT never exceed 81 dB(A), rectified noise is environment and not to any specific device such as an electrical machine. Protection against noise exposure can be in a limited frequency range and may be more objectionable to the ear than “white” noise, which handled in three ways: reduction in the level of the noise source, reduction in the transmission of noise, and control of consists of a variety of frequencies. noise at the receiver by protective equipment. For average sound pressure (Lp) dB(A) of a hemisphere with a 3 ft. radius, subtract 7dB(A). For 6 ft. radius, subtract 13dB(A). Since the noise to which a worker may be exposed is a For 10 ft. radius, subtract 17dB(A). function of all the noise sources around him/her, as well as the acoustical characteristics of the area, it is impossible, without a detailed knowledge of these values, to predict sound pressure levels on the workers’ ears. What is available 5.10 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. General Information Application Information FeeT FrOM THe CenTer BOTTOM OF THe MOTOr (CenTer OF nOISe SOUrCe) FEET FROM THE CENTER BOTTOM OF THE MOTOR (CENTER OF NOISE SOURCE) Motor Pricing 20 15 ∆dB 10 Modifications Pricing SOUND PRESSURE – SOUND POWER TRANSITION CURVE “A” NETWORK SOUND PRESSURE (REFERENCE .0002 MICROBARS) – SOUND POWER – ∆dB 5 0 6 8 10 12 14 16 Application Information Outline Dimensions Accessories & Modifications 4 Other 2 Terms 0 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 5.11 The following noise levels have been measured on typical machines of the listed frame size and are not guaranteed limits. CD500AT 105 CD287AT, CD288AT 100 CD258AT, CD259AT CD250AT 95 CD210AT 90 CD180AT 85 80 75 70 65 60 1000 2000 3000 4000 100 95 CD500AT 90 CD400AT 85 CD360AT CD320AT CD287AT, CD288AT 80 CD258AT, CD259AT 75 CD210AT 70 CD180AT 65 60 55 50 0 1000 MOTOR SPEED RPM Outline Dimensions 2000 3000 4000 MOTOR SPEED RPM nOISe leVelS FOr TYPICAl DPFG MOTOrS WITH MOTOr MOUnTeD BlOWerS Without Filter (Without Internal Fan) Operated From MG Set Supply 110 120 105 115 100 95 CD504AT-CD5010AY 90 CD320AT-CD400AT 85 CD280AT 80 AVERAGE SOUND POWER LEVEL (Lw) dB(A) RE 10-12 WATTS AVERAGE SOUND POWER LEVEL (Lw) dB(A) RE 10-12 WATTS Application Information Other CD400AT CD360AT AVERAGE SOUND POWER LEVEL (Lw) dB(A) RE 10-12 WATTS 110 0 Terms nOISe leVelS FOr TYPICAl DPFG DC MOTOrS Without Internal Fan (enclosed Separately Ventilated but Without external Air Supply) Operated from MG Set Supply nOISe leVel FOr TYPICAl DPFG DC MOTOrS (With Internal Fan) Operated from MG Set Supply AVERAGE SOUND POWER LEVEL (Lw) dB(A) RE 10-12 WATTS Accessories & Modifications Modifications Pricing Motor Pricing General Information Application Information CD6900 CD6800 110 CD6700 CD6200 105 100 CD6000 95 90 CD250AT 75 CD210AT CD180AT 70 0 0 500 1000 1500 MOTOR SPEED RPM 65 60 0 1000 2000 3000 4000 MOTOR SPEED RPM 5.12 CD6100 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 2000 2500 Air Flow requirements for Separately Ventilated Motors C enclosed Separately Ventilated Blown From Drive end Base Speed rPM CFM Standard Separately Ventilated 3500 2500 1750* 70 50 35 1.0 .6 .3 1.0 .6 .3 N/A N/A N/A CD210AT 3500 2500 1750* 180 130 90 1.6 .8 .4 2.96 1.5 .74 3.7 1.9 .9 CD250AT 3500 2500 1750* 320 230 160 1.8 .86 .45 3.28 1.66 .82 4.0 2.0 1.0 CD280AT 3500 2500 1750* 540 385 270 2.16 1.04 .54 3.92 1.96 .98 4.3 2.4 1.2 CD320AT ALL 650 2.0 3.2 3.0 CD360AT ALL 610 2.2 3.9 3.4 CD400AT ALL 830 2.6 3.65 4.0 CD504ATCD5010AY ALL 1425 3.0 4.1 3.8 Frame CD180AT Frame HP Base Speed rPM CFM Static Pressure Inches of Water CD6000 ALL ALL 2400 3 CD6100 ALL ALL 3400 3 CD6200 ALL ALL 4000 5 CD6700 ALL ALL 5000 5 CD6800 ≤1500 >1500 ALL ALL 6200 8000 5 8 CD6900 ≤2000 >2000 ALL ALL 7500 10000 5 9 Motor Pricing B nOTe: Airflows are for clean dry air less than 40°C (104°F) and at altitudes less than 1000 M (3330 FT). WArnInG: The static pressure values listed in the tabulations are based upon standard air inlet and standard air outlet utilization. The static pressure will be higher if either the air inlet or outlet openings are restricted in size or, in the case of air outlets, reduced in number. *1750 RPM or lower A. Standard Separately Ventilated Air in one CE opening with solid covers on other CE openings. Standard louvered covers on DE air outlets. Outline Dimensions B. enclosed Separately Ventilated (Air ducted in an air ducted out) Air in one CE opening with solid covers on other CE opening. Air out one DE opening. eSV CD6000 and Above SV eSV SV Standard Air Inlet Location CE TOP CE TOP DE* DE* Standard Air Exit Location DE (either side) DE Side and Bottom CE* CE** eSV - enclosed Separately Ventilated SV - Separately Ventilated Other Ce - Commutator end De - Drive end Application Information C. Blown From Drive end Air in one DE opening with solid covers on other DE openings. Standard louvered covers on CE air outlets. CD5010AY and Below Modifications Pricing A Accessories & Modifications STATIC PreSSUre InCHeS OF WATer General Information Application Information Terms *Motors are shipped with solid covers on both sides and top and bottom. Any DE cover may be removed for air entry and any CE cover for air exit. If a transparent cover is ordered, it will be located on the CE, conduit box side. **If a transparent cover is ordered, air exit is opposite conduit box side and bottom. If not transparent cover is ordered, air is exited on both sides. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 5.13 Blower Data for Blower Ventilated Motors Frame HP CD180AT CD210AT CD258AT, CD259AT CD287AT, CD288AT CD320AT CD360AT CD400AT CD504AT-CD5010AY 1/12 1/12 1/12 1/3 1 1 1 2 CD6000 CD6100 CD6200 CD6700 CD6800 <= 1500 HP > 1500 HP 5 7.5 10 15 15 15 CD6900 <= 2000 HP > 2000 HP 20 20 Hertz Phase rPM Full load Amperes 230/460 230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 230/460 230/460 230/460 230/460 60 60 60 60 60 60 60 60 60 60 60 60 60 3 3 3 3 3 3 3 3 3 3 3 3 3 3600 3600 3600 3600 3600 3600 3600 1800 1800 1800 1800 1800 1800 1.0/.50 1.0/.50 1.0/.50 1.8/.9 3.0/1.5 3.0/1.5 3.0/1.5 5.8/2.9 13.4/6.7 19.6/9.8 25.2/12.6 38.8/19.4 38.8/19.4 230/460 60 3 1800 Volts HP 1/12 1/12 1/12 1/3 1 1 1 2 3 5 7.5 10 10 REFER TO GE 49.6/24.8 15 REFER TO GE Phase 380 380 380 380 380 380 380 380 380 380 380 380 380 50 50 50 50 50 50 50 50 50 50 50 50 50 3 3 3 3 3 3 3 3 3 3 3 3 3 3000 3000 3000 3000 3000 3000 3000 1500 1500 1500 1500 1500 1500 N/A N/A N/A 0.76 1.6 1.6 1.6 3.0 5.2 8 11.4 15.8 15.8 380 50 3 1500 22.4 Volts The use of a 50 Hertz blower may affect motor frame size and will affect motor price and delivery. Refer to GE for use of 50 Hertz blowers. Full load amperes for blower motors are typical values. Suitable for operation with up to ±10% variation from rated voltage (e.g. 207-253V/414-506V, 60 Hz; 342-418V, 50 Hz) Application Information Other Terms 5.14 www.gemotors.com • 800-541-7191 Full load Amperes Hertz Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Application Information GEP387M 09/11 • Prices and data subject to change without notice. rPM Phase rPM 2 1/2 380 50 3 3000 3 3600 2 1 380 50 3 3000 60 3 3600 2 3 380 50 3 3000 230/460 230/460 60 60 3 3 3600 3600 1 1 7.5 3 380 380 50 50 3 3 3000 3000 5 230/460 60 3 3600 2 5 380 50 3 3000 1 1 7.5 5 230/460 230/460 60 60 3 3 3600 3600 1 1 7.5 5 380 380 50 50 3 3 3000 3000 CD6200 1 1 10 5 230/460 230/460 60 60 3 3 3600 3600 1 1 10 5 380 380 50 50 3 3 3000 3000 CD6700 1 2 15 5 230/460 230/460 60 60 3 3 3600 3600 1 2 15 5 380 380 50 50 3 3 3000 3000 CD6800 <= 1500HP 1 2 20 7.5 230/460 230/460 60 60 3 3 3600 3600 1 2 20 7.5 380 380 50 50 3 3 3000 3000 > 1500HP 1 2 25 7.5 230/460 230/460 60 60 3 3 3600 3600 1 2 25 7.5 380 380 50 50 3 3 3000 3000 CD6900 <= 2000HP 1 2 20 7.5 230/460 230/460 60 60 3 3 3600 3600 1 2 20 7.5 380 380 50 50 3 3 3000 3000 > 2000HP 1 2 30 10 230/460 230/460 60 60 3 3 3600 3600 1 2 30 7.5 380 380 50 50 3 3 3000 3000 Hertz Phase 2 1/2 230/460 60 3 CD400AT and CD504AT-CD508AT “A” COOLER 2 1 230/460 60 CD504AT-CD508AT “B” COOLER 2 3 230/460 CD5010AY 1 1 5 3 CD6000 2 CD6100 Volts Volts Hertz HP Hertz Phase rPM HP Hertz Phase rPM CD508AT 7.5 Volts 230/460 60 3 3600 5 Volts 380 50 3 3000 CD6000 7.5 230/460 60 3 3600 7.5 380 50 3 3000 CD6100 7.5 230/460 60 3 3600 7.5 380 50 3 3000 CD6200 10 230/460 60 3 3600 10 380 50 3 3000 CD6700 15 230/460 60 3 3600 15 380 50 3 3000 CD6800 <= 1500HP >= 1500HP 20 20 230/460 230/460 60 60 3 3 3600 3600 15 20 380 380 50 50 3 3 3000 3000 CD6900 <= 2000HP >= 2000HP 20 30 230/460 230/460 60 60 3 3 3600 3600 20 25 380 380 50 50 3 3 3000 3000 Application Information Blower Data for TeWAC Motors Frame Modifications Pricing HP 3600 HP CD360AT Frame Outline Dimensions rPM Blower Motor Qty. Blower Motor Qty. Accessories & Modifications Blower Data for TeAAC Motors Motor Pricing General Information Application Information Suitable for operation with up to ±10% variation from rated voltage (e.g. 207-253V/414-506V, 60 Hz; 342-418V, 50 Hz). Other Refer to Page 124 and 125 for Kinamatic and pages 141 through 144 for CD6000, for cooler dimensions used on specific motor ratings. Severe duty high efficiency motor option is also available. Refer to GE. 575 volts also available, contact GE for more information. Terms The use of 50 Hertz blower may effect motor frame size and will effect motor price and delivery. Refer to GE for use of 50 Hertz blowers. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 5.15 General Information Application Information Motor load Characteristics Constant Torque Drives DC motors operated with fixed shunt field excitation and adjustable armature voltage have an approximately constant torque capacity over their speed range. *Fig 1. Typical speed regulation Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing Many industrial applications such as conveyors, mixers, cement kilns, squeeze rolls, continuous processing machines, etc., require nearly constant torque over their operating speed range. (Refer to Fig. 2.) *Fig 2. Torque and HP Characteristics of constant-horsepower, constant torque load 5.16 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Stalled Current Capability The Continuous Load section defines the torque capability at all speeds considering the thermal limits. While the curves may seem to indicate an intersection at zero speed, the data only applies at speeds other than zero, but may be very low, such as 10 RPM. At zero speed, localized heating of the segments under the brushes may produce segment distortion and resulting brush vibration. Applications such as the center-driven winding reel often require a combination of constant torque and constant horsepower. (See Fig. 2 on the previous page) The horsepower required for a given linear speed of material is constant during the build-up of a roll. However, it is often desirable to change the surface speed when reeling different material. Since horsepower is proportional to the surface speed, armature voltage control will provide for the surface speed adjustments while the field control will provide the constant horsepower requirement during the build-up of the roll. Accessories & Modifications Constant Horsepower Drives Motor Pricing and Constant Torque HP = RPM x Torque 5,252 Modifications Pricing horsepower requirements of the load must be available at The load torque of a driven machine can be measured by wrapping a rope or cable around their input shaft or by using the lowest operating speed obtained by armature voltage control. a torque arm and applying a steady pull through a spring scale. The horsepower can then be calculated using the Combination of Constant Horsepower following relation: General Information Application Information A common example of a constant horsepower drive is a center driven winding reel. The material is wound on the mandrel at constant linear speed and constant tension using the following relation: Outline Dimensions HP = Linear Speed (FPM) x Tension (lb) 33,000 Application Information The horsepower is constant. At the start of the winding process, the torque requirement is low because of the small radius and the high rotational (motor) speed. As the roll builds up, the radius increases with a resulting increase in torque. The rotational speed must decrease in order to maintain constant linear speed. Other The main drives of metal working machines require approximately constant horsepower because an optimum cutting speed is maintained for particular types of material regardless of the diameter of the surface being machined. When machining small diameter stock, the torque requirement is low and the rotational speed is high. Stock of larger diameters require higher torque and decreased rotational speed. DC motors operated by field control and a constant armature voltage have a constant horsepower capacity over the speed range. (See Fig. 2 on the previous page) www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Terms In some applications, constant horsepower may be required over a wider speed range than is obtainable by field control. The additional speed range must be obtained by armature voltage control. Horsepower and speed are approximately proportional to the applied armature voltage, and the 5.17 notes Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Application Information 5.18 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Other Information Page Field Modification Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 General Information Index Standard Bearing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 Authorized Motor Service Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Terms and Conditions for Sale of Products and Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7 Motor Pricing Recommended Spare Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 6.1 Field Modification Kits Custom Modification Kits Custom modification kits allow modification of Kinamatic™ motors which have been shipped from the factory. They are designed for maximum flexibility and ease of installation, and are stocked by authorized GE parts distributors to provide immediate availability. The quick kit reference on the following pages lists the numbers of the most commonly used accessory kits and modification by frame size. Field modification kits cannot be mounted on all frame sizes or enclosures. Please review the application information carefully to determine availability. Contact GE (phone number available on page 6.4 of this document) or your GE parts distributor for kit prices. The information given is not to be used for new motor specifications. Blower Kits Blower kits are designed for standard mounting on the motor commutator end and for addition only to dripproof fully guarded, separately ventilated motors. Blower motors are 230/460 volt AC, 3 phase, 60 Hertz. To properly mount a blower kit on CD180AT frames, drilling and tapping of three holes is required. Tachometer Kits Tachometer kits are designed to be mounted on motors with an accessory comm end shaft extension of any fully guarded or totally enclosed Kinamatic motor, with the PY TACH KIT LESS TACH Frame Series Type C-Face Endshield Kits Type C-Face endshield kits are designed for mounting on the fully guarded or totally enclosed nonventilated (TENV) frames listed below. Addition of Type C-Face endshield kits requires machine disassembly by a qualified service facility. For frames CD218AT-CD2010AT, refer to factory. Frame Series Standard C-Face Dimension (in inches) CDL182AT-CD259AT 8.5 CD287AT & CD288AT 10.5 CD327AT, CD328AT, CD329AT 12.5 Sliding Bases Sliding bases are suggested as a convenient means for adjusting belt tension or may be used as mounting plates. (For horizontal mounting only — not available for ceiling or sidewall mounting. Sliding bases not available on CD6000 frames and above.) Lexan® Covers Lexan® covers are suggested as a convenient means of viewing brush rigging and brushes. Not available on frame sizes CDL182AT-CD189AT. BC TACH KIT LESS TACH AN-AC TACH 45/90V/1000RPM (INCLUDES TACH) CDL182AT-CD329AT 36A167701AAG01 36A167700AAG01 36A167702AAG01 CD365AT-CD368AT 36A167701BAG01 36A167700BAG01 36A167702BAG01 CD407AT-CDL409AT 36A167701CAG01 36A167700CAG01 36A167702CAG01 CD504AT-CD5010AY 36A167701CAG14 36A167700CAG01 36A167702DAG01 Frame Series AN-DG240L3 240 PPR ONE OUTPUT AN-DG240L4 240 PPR DUAL OUTPUT AN-DG600L3 600 PPR ONE OUTPUT AN-DG600L4 600 PPR DUAL OUTPUT CDL182AT-CD329AT 36C706050DA001 36C706050DB001 36C706050DC001 36C706050DD001 CD365AT-CD368AT 36C706050AB001 36C706050AB001 36C706050AC001 36C706050AD001 CD407AT-CDL409AT 36C706050AB002 36C706050AB002 36C706050AC002 36C706050AD002 CD504AT-CD5010AY 36C706050AB003 36C706050AB003 36C706050AC003 36C706050AD003 *Bi-directional, dual output. Terms Other exception of totally enclosed fan cooled (TEFC) machines. Tach adapters are made of cast iron and are supplied with appropriate covers. Refer to GE for mounting of tachometer kits on TEFC motors. Note: Type BC and Type PY tachometers must be ordered independently of the tachometer kits less tachometer. Application Information Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Frames CD180AT to CD5010AY 6.2 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Field Modification Kits DC BC46 TACH ONLY (USES BC KIT) 50V/1000 RPM 897A594-002 50V/1000 RPM 897A590-032 50V/1000 RPM 897A591-041 100V/1000 RPM 897A594-001 100V/1000 RPM 897A590-024 100V/1000 RPM 897A591-029 BLOWER KIT LESS FILTER BLOWER KIT WITH FILTER CD218AT-CD2110AT 36A167741CAG01 36A167742AAG02 36A167741CBG01 36A167742ABG02 36A172472AAG01 36A167802BAG02 CD258AT-CD259AT 36A167743AAG02 36A167743ABG02 36A172473AAG01 36A167803BAG02 CD287AT-CD288AT 36A167744AAG03 36A167744ABG03 36A172474AAG01 36A167805BAG02 CD327AT-CD329AT 36A167745GAG10 36A167745GBG10 36A172475AAG01 36A167806BAG02 CD365AT-CD368AT 36A167746GAG10 36A167746GBG10 NOT AVAILABLE 36A167807BAG02 Frame Series CDL182AT-CD189AT C-FACE KIT LEXAN® COVERS (Qty. 2 required) NOT AVAILABLE 36A167747GAG10 36A167747GBG10 NOT AVAILABLE 36A167809BAG02 36A167747GCG10 36A167747GDG10 NOT AVAILABLE 36B473083CAG01 CD504AT-CD5010AY 36A167749EAG30 36A167749EBG34 NOT AVAILABLE 36B473084CAG01 533C400-001 533C400-001 CD189AT 533C400-023 CD218AT 533C400-019 CD219AT 533C400-022 CD2110AT 533C400-039 CD258AT 533C400-040 CD259AT 533C400-041 CD287AT 533C400-020 CD288AT 533C400-042 CD327AT 533C400-043 CD328AT 533C400-044 CD329AT 533C400-067 CD365AT 533C400-011 CD366AT 533C400-012 CD368AT 533C400-046 CD407AT 533C400-047 CDL407AT 533C400-047 CD409AT 533C400-048 CDL409AT 533C400-048 CD504AT 533C400-017 CDL504AT 533C400-017 CD506AT 533C400-049 CDL506AT 533C400-049 CD508AT 533C400-050 CDL508AT 533C400-050 CD5010AY 533C400AK001 Outline Dimensions CD186AT CDL186AT Application Information 533C400-034 Other Sliding Base CDL182AT Accessories & Modifications CD407AT & CD409AT CDL407AT & CDL409AT Frame Series Motor Pricing DC BC42 TACH ONLY (USES BC KIT) Modifications Pricing DC PY TACH ONLY (USES PY KIT) General Information Frames CD180AT to CD5010AY www.gemotors.com • 800-541-7191 Terms Blower motor is 230/460 Volt AC, 3 phase, 60 Hertz. Requires drilling and tapping of three holes to install. Requires motor disassembly by qualified service facility to install. For dripproof motors use 36A172471AAG02. For totally enclosed motors use 36A172471AAG01. For commutator end only. GEP387M 09/11 • Prices and data subject to change without notice. 6.3 Renewal Parts Service Parts available directly from authorized GE parts distributors. For authorized distributor information or technical support, call toll free: 1-877-458-0451. The Kinamatic motor is designed for tough industrial applications. Maintain the original performance standards of the Kinamatic design by using genuine GE renewal parts. Repair service is available from authorized GE service facilities. Kinamatic renewal parts, such as main and commutator coils, pole assemblies, and armature coils are produced to original factory specifications including form fits, materials, and dimensions. Recommended Spare Parts As insurance against costly downtime, it is strongly recommended that spare parts be kept on hand in accordance with the chart below: A permanently attached stainless steel nameplate displays the model and serial number, providing all the information needed for ordering. NUMBER OF DUPLICATE MOTORS IN SERVICE Description 1 2-4 5-10 11-20 More Than 20 Complete Machine - - - 1 2 Drive End Ball Bearing 1 1 1 2 3 Front End Ball Bearing 1 1 1 2 3 Brushes (Sets) 2 4 4 8 10 Brushholders (Sets) - 1 1 1 1 Brushholder Springs (Sets) 1 1 1 2 2 Main Field Coil and Pole - 1 1 2 3 Commutating Field Coil and Pole - 1 1 2 3 Armature, Complete - 1 1 2 2 Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Recommended Spare Parts List 6.4 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. General Information Standard Bearing Information Motor Pricing The following chart shows the standard ball bearings used in Kinamatic motors. This chart does not apply to motors with roller bearings. Non-standards are manufactured for special applications. Therefore, not all Kinamatic motors follow the chart below. Refer to GE for non-standard motors. STANDARD BEARINGS FOR DC MOTORS GE Part Number Bearing Size AFBMA # GE Part Number CD140AT 6205 25BC02JPP3 894A605ZJ 005 6204 20BC02JPP3 894A605ZJ 004 CD180AT 6206 30BC02JPP3 894A605ZJ 006 6206 30BC02JPP3 894A605ZJ 006 CD210AT 6207 35BC02JPP3 894A605ZJ 007 6206 30BC02JPP3 894A605ZJ 006 CD250AT 6209 45BC02X3 894A605 009 6207 35BC02X3 894A605 007 CD280AT 6210 50BC02X3 894A605 010 6209 45BC02X3 894A605 009 CD320AT 6211 55BC02X3 894A605 011 6210 50BC02X3 894A605 010 6213 65BC02X3 894A605 013 6211 55BC02X3 894A605 011 6214 70BC02X3 894A605 014 6213 65BC02X3 894A605 013 CD504AT/CD508AT 6218 90BC02X3 894A605 018 6216 80BC02X3 894A605 016 CD5010AY 6222 110BC02X3 894A605 022 6218 90BC02X3 894A605 018 CD6000 6224 120BC02X3 894A605 023 6220 100BC02X3 894A605 020 CD6100 6228 140BC02X3 894A605 025 6224 120BC02X3 894A605 023 CD6200 6232 160BC02X3 894A605 027 6228 140BC02X3 894A605 025 CD6700 6236 180BC02X3 894A605 029 6236 180BC02X3 894A605 029 CD6800 6236 180BC02X3 894A605 029 6236 180BC02X3 894A605 029 CD6900 6240 200BC02X3 894A605 031 6240 200BC02X3 894A605 031 Terms Other Application Information CD360AT CD400AT Accessories & Modifications AFBMA # Modifications Pricing COMM END Bearing Size Outline Dimensions Frame Size DRIVE END www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 6.5 Authorized Motor Service Centers Before warranty service is commenced on any Motors product, please contact Post Sale Service at: USA and Canada: (866) 563-1284 International: (260) 439-4451 Email: gemotorspss@ge.com Visit us online to find an authorized motor service center in your region. Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information www.gemotors.com 6.6 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Terms and Conditions for Sale of Products and Services “Insolvent/Bankrupt” means that a party is insolvent, makes an assignment for the benefit of its creditors, has a receiver or trustee appointed for it or any of its assets, or files or has filed against it a proceeding under any bankruptcy, insolvency dissolution or liquidation laws. “Products” means the equipment, parts, materials, supplies, software, and other goods Seller has agreed to supply to Buyer under the Contract. www.gemotors.com • 800-541-7191 guarantee allowing for pro-rata payments as Products are shipped and Services are performed, plus payment of cancellation and termination charges, and all other amounts due from Buyer under the Contract (“Payment Security”). The Payment Security shall be (a) in a form, and issued or confirmed by a bank acceptable to Seller, (b) payable at the counters of such acceptable bank or negotiating bank, (c) opened at least sixty (60) days prior to both the earliest scheduled shipment of Products and commencement of GEP387M 09/11 • Prices and data subject to change without notice. 6.7 Motor Pricing Modifications Pricing 2.1 Buyer shall pay Seller for the Products and Services by paying all invoiced amounts in U.S. dollars, without set-off for any payment from Seller not due under this Contract, “Contract” means either the contract agreement signed by within thirty (30) days from the invoice date. If the Contract both parties, or the purchase order signed by Buyer and Price is less than U.S. Two Hundred Fifty Thousand Dollars accepted by Seller in writing, for the sale of Products or ($250,000), Seller shall issue invoices upon shipment of Services, together with these Terms and Conditions, Seller’s Products and as Services are performed. If the Contract Price final quotation, the agreed scope(s) of work, and Seller’s is U.S. Two Hundred Fifty Thousand Dollars ($250,000) or order acknowledgement. In the event of any conflict, the more, progress payments shall be invoiced starting with Terms and Conditions shall take precedence over other twenty-five percent (25%) of the Contract Price for Products documents included in the Contract. and Services upon the earlier of Contract signature or “Contract Price” means the agreed price stated in the issuance of Seller’s order acknowledgement and continuing Contract for the sale of Products and Services, including such that ninety percent (90%) of the Contract Price for adjustments (if any) in accordance with the Contract. Products is received before the earliest scheduled Product shipment and Services are invoiced as performed (“Progress “Hazardous Materials” means any toxic or hazardous Payments”). For each calendar month, or fraction thereof, substance, hazardous material, dangerous or hazardous that payment is late, Buyer shall pay a late payment charge waste, dangerous good, radioactive material, petroleum or computed at the rate of 1.5% per month on the overdue petroleum-derived products or by-products, or any other chemical, substance, material or emission, that is regulated, balance, or the maximum rate permitted by law, whichever listed or controlled pursuant to any national, state, provincial, is less. or local law, statute, ordinance, directive, regulation or other 2.2 As and if requested by Seller, Buyer shall at its expense legal requirement of the United States (“U.S.”) or the country establish and keep in force payment security in the form of of the Site. an irrevocable, unconditional, sight letter of credit or bank “Buyer” means the entity to which Seller is providing Products or Services under the Contract. Accessories & Modifications “Terms and Conditions” means these “Terms and Conditions for Sale of Products and Services”, including any relevant addenda pursuant to Article 18, together with any modifications or additional provisions specifically stated in Seller’s final quotation or specifically agreed upon by Seller in writing. Outline Dimensions 2. Payment “Site” means the premises where Products are used or Services are performed, not including Seller’s premises from which it performs Services. Application Information 1. Definitions “Services” means the services Seller has agreed to perform for Buyer under the Contract. Other “Seller” means the entity providing Products or performing Services under the Contract. Terms NOTICE: Sale of any Products or Services is expressly conditioned on Buyer's assent to these Terms and Conditions. Any acceptance of Seller’s offer is expressly limited to acceptance of these Terms and Conditions and Seller expressly objects to any additional or different terms proposed by Buyer. No facility entry form shall modify these Terms and Conditions even if signed by Seller’s representative. Any order to perform work and Seller's performance of work shall constitute Buyer’s assent to these Terms and Conditions. Unless otherwise specified in the quotation, Seller’s quotation shall expire 30 days from its date and may be modified or withdrawn by Seller before receipt of Buyer’s conforming acceptance. General Information Form ES 104 (Rev. 4) Terms and Conditions for Sale of Products and Services Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Form ES 104 (Rev. 4) Services, and (d) remain in effect until the latest of ninety (90) days after the last scheduled Product shipment, completion of all Services and Seller’s receipt of the final payment required under the Contract. Buyer shall, at its expense, increase the amount(s), extend the validity period(s) and make other appropriate modifications to any Payment Security within ten (10) days of Seller’s notification that such adjustment is necessary in connection with Buyer’s obligations under the Contract. Seller’s facility or warehouse (Incoterms 2010). For export shipments, Seller shall deliver Products to Buyer FCA Port of Export (Incoterms 2010). Buyer shall pay all delivery costs and charges or pay Seller’s standard shipping charges plus up to twenty-five (25%) percent. Partial deliveries are permitted. Seller may deliver Products in advance of the delivery schedule. Delivery times are approximate and are dependent upon prompt receipt by Seller of all information necessary to proceed with the work without interruption. If Products delivered do not correspond in quantity, type 2.3 Seller is not required to commence or continue its or price to those itemized in the shipping invoice or docuperformance unless and until any required Payment Security is received, operative and in effect and all applicable mentation, Buyer shall so notify Seller within ten (10) days after receipt. Progress Payments have been received. For each day of delay in receiving Progress Payments or acceptable Payment 4.2 For shipments that do not involve export, title to Products shall pass to Buyer upon delivery in accordance Security, Seller shall be entitled to a matching extension of with Section 4.1. For export shipments from a Seller facility the schedule. If at any time Seller reasonably determines that Buyer’s financial condition or payment history does not or warehouse outside the U.S., title shall pass to Buyer upon delivery in accordance with Section 4.1. For shipments justify continuation of Seller’s performance, Seller shall be from the U.S. to another country, title shall pass to Buyer entitled to require full or partial payment in advance or immediately after each item departs from the territorial otherwise restructure payments, request additional forms land, seas and overlying airspace of the U.S. The 1982 United of Payment Security, suspend its performance or terminate Nations Convention of the law of the Sea shall apply to the Contract. determine the U.S. territorial seas. For all other shipments, 3. Taxes and Duties title to Products shall pass to Buyer the earlier of (i) the port of export immediately after Products have been cleared for Seller shall be responsible for all corporate taxes measured export or (ii) immediately after each item departs from the by net income due to performance of or payment for work territorial land, seas and overlying airspace of the sending under this Contract (“Seller Taxes”). Buyer shall be responsible for all taxes, duties, fees, or other charges of any nature country. When Buyer arranges the export or intercommunity shipment, Buyer will provide Seller evidence of exportation (including, but not limited to, consumption, gross receipts, import, property, sales, stamp, turnover, use, or value-added or intercommunity shipment acceptable to the relevant tax and custom authorities. Notwithstanding the foregoing, taxes, and all items of withholding, deficiency, penalty, Seller grants only a license, and does not pass title, for any addition to tax, interest, or assessment related thereto, imposed by any governmental authority on Buyer or Seller or software provided by Seller under this Contract, and title to any leased equipment remains with Seller. its subcontractors) in relation to the Contract or the performance of or payment for work under the Contract other than 4.3 Risk of loss shall pass to Buyer upon delivery pursuant to Seller Taxes (“Buyer Taxes”). The Contract Price does not Section 4.1, except that for export shipments from the U.S., include the amount of any Buyer Taxes. If Buyer deducts or risk of loss shall transfer to Buyer upon title passage. withholds Buyer Taxes, Buyer shall pay additional amounts 4.4 If any Products to be delivered under this Contract or if so that Seller receives the full Contract Price without reducany Buyer equipment repaired at Seller’s facilities cannot be tion for Buyer Taxes. Buyer shall provide to Seller, within one shipped to or received by Buyer when ready due to any month of payment, official receipts from the applicable cause attributable to Buyer or its other contractors, Seller governmental authority for deducted or withheld taxes. may ship the Products and equipment to a storage facility, 4. Deliveries; Title Transfer; Risk of Loss; Storage including storage at the place of manufacture or repair, or to an agreed freight forwarder. If Seller places Products or 4.1 For shipments that do not involve export, including equipment into storage, the following apply: (i) title and risk shipments from one European Union (“EU”) country to of loss immediately pass to Buyer, if they have not already another EU country, Seller shall deliver Products to Buyer FCA 6.8 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Terms and Conditions for Sale of Products and Services 5.3 If Products or Services do not meet the above warranties, Buyer shall promptly notify Seller in writing prior to expiration of the warranty period. Seller shall (i) at its option, repair or replace defective Products and (ii) re-perform defective Services. If despite Seller’s reasonable efforts, a non-conforming Product cannot be repaired or replaced, or non-conforming Services cannot be re-performed, Seller shall refund or credit monies paid by Buyer for such nonconforming Products and Services. Warranty repair, replacement or re-performance by Seller shall not extend or renew the applicable warranty period. Buyer shall obtain Seller’s agreement on the specifications of any tests it plans to conduct to determine whether a non-conformance exists. 5.4 Buyer shall bear the costs of access for Seller’s remedial warranty efforts (including removal and replacement of systems, structures or other parts of Buyer’s facility), de installation, decontamination, re installation and transportation of defective Products to Seller and back to Buyer. www.gemotors.com • 800-541-7191 6.1 Seller and Buyer (as to information disclosed, the “Disclosing Party”) may each provide the other party (as to information received, the “Receiving Party”) with Confidential Information in connection with this Contract. “Confidential Information” means (a) information that is designated in writing as “confidential” or “proprietary” by Disclosing Party at the time of written disclosure, and (b) information that is orally designated as “confidential” or “proprietary” by Disclosing Party at the time of oral or visual disclosure and is confirmed to be “confidential” or “proprietary” in writing within twenty (20) days after the oral or visual disclosure. In addition, prices for Products and Services shall be considered Seller’s Confidential Information. 6.2 Receiving Party agrees: (i) to use the Confidential Information only in connection with the Contract and use of Products and Services, (ii) to take reasonable measures to prevent disclosure of the Confidential Information to third parties, and (iii) not to disclose the Confidential Information to a competitor of Disclosing Party. Notwithstanding these restrictions, (a) Seller may disclose Confidential Information to its affiliates and subcontractors in connection with performance of the Contract, (b) a Receiving Party may disclose Confidential Information to its auditors, (c) Buyer GEP387M 09/11 • Prices and data subject to change without notice. 6.9 Motor Pricing Modifications Pricing Accessories & Modifications 6. Confidentiality Outline Dimensions 5.2 The warranty for Products shall expire one (1) year from first use or eighteen (18) months from delivery, whichever occurs first, except that software is warranted for ninety (90) days from delivery. The warranty for Services shall expire one (1) year after performance of the Service, except that software-related Services are warranted for ninety (90) days. Application Information 5.6 This Article 5 provides the exclusive remedies for all claims based on failure of or defect in Products or Services, regardless of when the failure or defect arises, and whether a claim, however described, is based on contract, warranty, indemnity, tort/extra-contractual liability (including negligence), strict liability or otherwise. The warranties provided 5. Warranty in this Article 5 are exclusive and are in lieu of all other 5.1 Seller warrants that Products shall be delivered free from warranties, conditions and guarantees whether written, oral, defects in material, workmanship and title and that Services implied or statutory. NO IMPLIED OR STATUTORY WARRANTY, OR WARRANTY OR CONDITION OF MERCHANTABILITY OR shall be performed in a competent, diligent manner in FITNESS FOR A PARTICULAR PURPOSE APPLIES. accordance with any mutually agreed specifications. Other 4.5 If repair Services are to be performed on Buyer’s equipment at Seller’s facility, Buyer shall be responsible for, and shall retain risk of loss of, such equipment at all times, except that Seller shall be responsible for damage to the equipment while at Seller’s facility to the extent such damage is caused by Seller’s negligence. 5.5 The warranties and remedies are conditioned upon (a) proper storage, installation, use, operation, and maintenance of Products, (b) Buyer keeping accurate and complete records of operation and maintenance during the warranty period and providing Seller access to those records, and (c) modification or repair of Products or Services only as authorized by Seller in writing. Failure to meet any such conditions renders the warranty null and void. Seller is not responsible for normal wear and tear. Terms passed, and delivery shall be deemed to have occurred; (ii) any amounts otherwise payable to Seller upon delivery or shipment shall be due; (iii) all expenses and charges incurred by Seller related to the storage shall be payable by Buyer upon submission of Seller’s invoices; and (iv) when conditions permit and upon payment of all amounts due, Seller shall make Products and repaired equipment available to Buyer for delivery. General Information Form ES 104 (Rev. 4) Terms and Conditions for Sale of Products and Services Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Form ES 104 (Rev. 4) may disclose Confidential Information to lenders as necessary for Buyer to secure or retain financing needed to perform its obligations under the Contract, and (d) a Receiving Party may disclose Confidential Information to any other third party with the prior written permission of Disclosing Party, and in each case, only so long as the Receiving Party obtains a non-disclosure commitment from any such subcontractors, auditors, lenders or other permitted third party that prohibits disclosure of the Confidential Information and provided further that the Receiving Party remains responsible for any unauthorized use or disclosure of the Confidential Information. Receiving Party shall upon request return to Disclosing Party or destroy all copies of Confidential Information except to the extent that a specific provision of the Contract entitles Receiving Party to retain an item of Confidential Information. Seller may also retain one archive copy of Buyer’s Confidential Information. 6.3 The obligations under this Article 6 shall not apply to any portion of the Confidential Information that: (i) is or becomes generally available to the public other than as a result of disclosure by Receiving Party, its representatives or its affiliates; (ii) is or becomes available to Receiving Party on a non-confidential basis from a source other than Disclosing Party when the source is not, to the best of Receiving Party’s knowledge, subject to a confidentiality obligation to Disclosing Party; (iii) is independently developed by Receiving Party, its representatives or affiliates, without reference to the Confidential Information; (iv) is required to be disclosed by law or valid legal process provided that the Receiving Party intending to make disclosure in response to such requirements or process shall promptly notify the Disclosing Party in advance of such disclosure and reasonably cooperate in attempts to maintain the confidentiality of the Confidential Information. 6.4 Each Disclosing Party warrants that it has the right to disclose the information that it discloses. Neither Buyer nor Seller shall make any public announcement about the Contract without prior written approval of the other party. As to any individual item of Confidential Information, the restrictions under this Article 6 shall expire five (5) years after the date of disclosure. Article 6 does not supersede any separate confidentiality or nondisclosure agreement signed by the parties. 6.10 www.gemotors.com • 800-541-7191 7. Intellectual Property 7.1 Seller shall defend and indemnify Buyer against any claim by a non-affiliated third party (a “Claim”) alleging that Products or Services furnished under this Contract infringe a patent in effect in the U.S., an EU member state or the country of the Site (provided there is a corresponding patent issued by the U.S. or an EU member state), or any copyright or trademark registered in the country of the Site, provided that Buyer (a) promptly notifies Seller in writing of the Claim, (b) makes no admission of liability and does not take any position adverse to Seller, (c) gives Seller sole authority to control defense and settlement of the Claim, and (d) provides Seller with full disclosure and reasonable assistance as required to defend the Claim. 7.2 Section 7.1 shall not apply and Seller shall have no obligation or liability with respect to any Claim based upon (a) Products or Services that have been modified, or revised, (b) the combination of any Products or Services with other products or services when such combination is a basis of the alleged infringement, (c) failure of Buyer to implement any update provided by Seller that would have prevented the Claim, (d) unauthorized use of Products or Services, or (e) Products or Services made or performed to Buyer’s specifications. 7.3 Should any Product or Service, or any portion thereof, become the subject of a Claim, Seller may at its option (a) procure for Buyer the right to continue using the Product or Service, or applicable portion thereof, (b) modify or replace it in whole or in part to make it non-infringing, or (c) failing (a) or (b), take back infringing Products or Services and refund the price received by Seller attributable to the infringing Products or Services. 7.4 Article 7 states Seller’s exclusive liability for intellectual property infringement by Products and Services. 7.5 Each party shall retain ownership of all Confidential Information and intellectual property it had prior to the Contract. All new intellectual property conceived or created by Seller in the performance of this Contract, whether alone or with any contribution from Buyer, shall be owned exclusively by Seller. Buyer agrees to deliver assignment documentation as necessary to achieve that result. GEP387M 09/11 • Prices and data subject to change without notice. Terms and Conditions for Sale of Products and Services 10. Excusable Events Seller shall not be liable or considered in breach of its obligations under this Contract to the extent that Seller’s performance is delayed or prevented, directly or indirectly, by any cause beyond its reasonable control, or by armed conflict, acts or threats of terrorism, epidemics, strikes or other labor disturbances, or acts or omissions of any governmental authority or of the Buyer or Buyer’s contractors or suppliers. If an excusable event occurs, the schedule for Seller’s performance shall be extended by the amount of time lost by reason of the event plus such additional time as may be needed to overcome the effect of the event. If acts or omissions of the Buyer or its contractors or suppliers cause the delay, Seller shall also be entitled to an equitable price adjustment. 11. Termination and Suspension 11.1 Buyer may terminate the Contract (or the portion affected) for cause if Seller (i) becomes Insolvent/Bankrupt, www.gemotors.com • 800-541-7191 11.4 If the Contract (or any portion thereof) is terminated for any reason other than Seller’s default under Section 11.1, Buyer shall pay Seller for all Products completed, lease fees incurred and Services performed before the effective date of termination, plus expenses reasonably incurred by Seller in connection with the termination. The amount due for Services shall be determined in accordance with the milestone schedule (for completed milestones) and rates set forth in the Contract (for work toward milestones not yet achieved and where there is no milestone schedule), as applicable or, where there are no milestones and/or rates in the Contract, at Seller’s then-current standard time and material rates. In addition, Buyer shall pay Seller a cancellation charge equal to 80% of the Contract Price applicable to uncompleted made-to-order Products and 15% of the Contract Price applicable to all other uncompleted Products. 11.5 Either Buyer or Seller may terminate the Contract (or the portion affected) upon twenty (20) days advance notice if there is an excusable event (as described in Article 10) GEP387M 09/11 • Prices and data subject to change without notice. 6.11 Motor Pricing Modifications Pricing Accessories & Modifications 11.3 Seller may suspend or terminate the Contract (or any affected portion thereof) immediately for cause if Buyer (i) becomes Insolvent/Bankrupt, or (ii) materially breaches the Contract, including, but not limited to, failure or delay in Buyer providing Payment Security, making any payment when due, or fulfilling any payment conditions. Outline Dimensions During the term of the Contract, Seller shall maintain for its protection the following insurance coverage: (i) Worker’s Compensation, Employer’s Liability and other statutory insurance required by law with respect to work related injuries or disease of employees of Seller in such form(s) and amount(s) as required by applicable laws; (ii) Automobile Liability insurance with a combined single limit of $2,500,000.00; and (iii) Commercial General Liability or Public Liability insurance for bodily injury and property damage with a combined single limit of $2,500,000.00. If required in the Contract, Seller shall provide a certificate of insurance reflecting such coverage. Application Information 9. Insurance 11.2 If Buyer terminates the Contract pursuant to Section 11.1, (i) Seller shall reimburse Buyer the difference between that portion of the Contract Price allocable to the terminated scope and the actual amounts reasonably incurred by Buyer to complete that scope, and (ii) Buyer shall pay to Seller (a) the portion of the Contract Price allocable to Products completed, (b) lease fees incurred, and (c) amounts for Services performed before the effective date of termination. The amount due for Services shall be determined in accordance with the milestone schedule (for completed milestones) and rates set forth in the Contract (for work toward milestones not yet achieved and where there is no milestone schedule), as applicable or, where there are no milestones and/or rates in the Contract, at Seller’s then-current standard time and material rates. Other Each of Buyer and Seller (as an “Indemnifying Party”) shall indemnify the other party (as an “Indemnified Party”) from and against claims brought by a third party, on account of personal injury or damage to the third party’s tangible property, to the extent caused by the negligence of the Indemnifying Party in connection with this Contract. In the event the injury or damage is caused by joint or concurrent negligence of Buyer and Seller, the loss or expense shall be borne by each party in proportion to its degree of negligence. For purposes of Seller’s indemnity obligation, no part of the Products or Site is considered third party property. or (ii) commits a material breach of the Contract which does not otherwise have a specified contractual remedy, provided that: (a) Buyer shall first provide Seller with detailed written notice of the breach and of Buyer’s intention to terminate the Contract, and (b) Seller shall have failed, within 30 days after receipt of the notice, to commence and diligently pursue cure of the breach. Terms 8. Indemnity General Information Form ES 104 (Rev. 4) Terms and Conditions for Sale of Products and Services Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Form ES 104 (Rev. 4) lasting longer than one hundred and twenty (120) days. In such case, Buyer shall pay to Seller amounts payable under Section 11.4, excluding the cancellation charge for uncompleted Products. 11.6 Buyer shall pay all reasonable expenses incurred by Seller in connection with a suspension, including, but not limited to, expenses for repossession, fee collection, demobilization/remobilization, and costs of storage during suspension. The schedule for Seller’s obligations shall be extended for a period of time reasonably necessary to overcome the effects of any suspension. 12. Compliance with Laws, Codes and Standards 12.1 Seller shall comply with laws applicable to the manufacture of Products and its performance of Services. Buyer shall comply with laws applicable to the application, operation, use and disposal of the Products and Services. 12.2 Seller’s obligations are conditioned upon Buyer’s compliance with all U.S. and other applicable trade control laws and regulations. Buyer shall not trans-ship, re-export, divert or direct Products other than in and to the ultimate country of destination declared by Buyer and specified as the country of ultimate destination on Seller’s invoice. 13.2 Buyer shall timely advise Seller in writing of all applicable Site-specific health, safety, security and environmental requirements and procedures. Without limiting Buyer’s responsibilities under Article 13, Seller has the right but not the obligation to, from time to time, review and inspect applicable health, safety, security and environmental documentation, procedures and conditions at the Site. 13.3 If, in Seller’s reasonable opinion, the health, safety, or security of personnel or the Site is, or is apt to be, imperiled by security risks, terrorist acts or threats, the presence of or threat of exposure to Hazardous Materials, or unsafe working conditions, Seller may, in addition to other rights or remedies available to it, evacuate some or all of its personnel from Site, suspend performance of all or any part of the Contract, and/or remotely perform or supervise work. Any such occurrence shall be considered an excusable event. Buyer shall reasonably assist in any such evacuation. 13.4 Operation of Buyer’s equipment is the responsibility of Buyer. Buyer shall not require or permit Seller’s personnel to operate Buyer’s equipment at Site. 13.5 Buyer will make its Site medical facilities and resources available to Seller personnel who need medical attention. 13.6 Seller has no responsibility or liability for the pre-existing condition of Buyer’s equipment or the Site. Prior to Seller 12.3 Notwithstanding any other provision, Buyer shall timely starting any work at Site, Buyer will provide documentation obtain, effectuate and maintain in force any required permit, that identifies the presence and condition of any Hazardous license, exemption, filing, registration and other authorizaMaterials existing in or about Buyer’s equipment or the Site tion, including, but not limited to, building and environmental that Seller may encounter while performing under this permits, import licenses, environmental impact assessments, Contract. Buyer shall disclose to Seller industrial hygiene and and foreign exchange authorizations, required for the lawful environmental monitoring data regarding conditions that may performance of Services at the Site or fulfillment of Buyer’s affect Seller’s work or personnel at the Site. Buyer shall keep obligations, except that Seller shall obtain any license or Seller informed of changes in any such conditions. registration necessary for Seller to generally conduct 13.7 Seller shall notify Buyer if Seller becomes aware of: business and visas or work permits, if any, necessary for (i) conditions at the Site differing materially from those Seller’s personnel. Buyer shall provide reasonable assistance disclosed by Buyer, or (ii) previously unknown physical to Seller in obtaining such visas and work permits. conditions at Site differing materially from those ordinarily encountered and generally recognized as inherent in work 13. Environmental, Health and Safety Matters of the character provided for in the Contract. If any such 13.1 Buyer shall maintain safe working conditions at the Site, conditions cause an increase in Seller's cost of, or the time including, without limitation, implementing appropriate required for, performance of any part of the work under the procedures regarding Hazardous Materials, confined space Contract, an equitable adjustment in price and schedule entry, and energization and de-energization of power shall be made. systems (electrical, mechanical and hydraulic) using safe and 13.8 If Seller encounters Hazardous Materials in Buyer’s effective lock-out/tag-out (“LOTO”) procedures including physical LOTO or a mutually agreed upon alternative method. equipment or at the Site that require special handling or disposal, Seller is not obligated to continue work affected by 6.12 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Terms and Conditions for Sale of Products and Services 14.2 The scope, Contract Price, schedule, and other provisions will be equitably adjusted to reflect additional costs or obligations incurred by Seller resulting from a change, after Seller’s proposal date, in Buyer’s Site-specific requirements or procedures, or in industry specifications, codes, standards, applicable laws or regulations. However, no adjustment will be made on account of a general change in Seller’s manufacturing or repair facilities resulting from a change in laws or regulations applicable to such facilities. Unless otherwise agreed by the parties, pricing for additional work arising from such changes shall be at Seller’s time and material rates. 14.3 It shall be acceptable and not considered a change if Seller delivers a Product that bears a different, superseding or new part or version number compared to the part or version number listed in the Contract. 15. Limitations of Liability 15.1 The total liability of Seller for all claims of any kind arising from or related to the formation, performance or www.gemotors.com • 800-541-7191 15.5 If Buyer is supplying Products or Services to a third party, or using Products or Services at a facility owned by a third party, Buyer shall either (i) indemnify and defend Seller from and against any and all claims by, and liability to, any such third party in excess of the limitations set forth in this Article 15, or (ii) require that the third party agree, for the benefit of and enforceable by Seller, to be bound by all the limitations included in this Article 15. 15.6 For purposes of this Article 15, the term “Seller” means Seller, its affiliates, subcontractors and suppliers of any tier, and their respective employees. The limitations in this Article 15 shall apply regardless of whether a claim is based in contract, warranty, indemnity, tort/extra-contractual liability (including negligence), strict liability or otherwise, and shall prevail over any conflicting terms, except to the extent that such terms further restrict Seller’s liability. Motor Pricing Modifications Pricing Accessories & Modifications 15.4 Seller shall not be liable for advice or assistance that is not required for the work scope under this Contract. Outline Dimensions 14.1 Each party may at any time propose changes in the schedule or scope of Products or Services. Seller is not obligated to proceed with any change until both parties agree upon such change in writing. The written change documentation will describe the changes in scope and schedule, and the resulting changes in price and other provisions, as agreed. 15.3 All Seller liability shall end upon expiration of the applicable warranty period, provided that Buyer may continue to enforce a claim for which it has given notice prior to that date by commencing an action or arbitration, as applicable under this Contract, before expiration of any statute of limitations or other legal time limitation but in no event later than one year after expiration of such warranty period. Application Information 14. Changes 15.2 Seller shall not be liable for loss of profit or revenues, loss of use of equipment or systems, interruption of business, cost of replacement power, cost of capital, downtime costs, increased operating costs, any special, consequential, incidental, indirect, or punitive damages, or claims of Buyer’s customers for any of the foregoing types of damages. Other 13.9 Buyer shall indemnify Seller for any and all claims, damages, losses, and expenses arising out of or relating to any Hazardous Materials which are or were (i) present in or about Buyer’s equipment or the Site prior to the commencement of Seller’s work, (ii) improperly handled or disposed of by Buyer or Buyer’s employees, agents, contractors or subcontractors, or (iii) brought, generated, produced or released on Site by parties other than Seller. breach of this Contract, or any Products or Services, shall not exceed the (i) Contract Price, or (ii) if Buyer places multiple order(s) under the Contract, the price of each particular order for all claims arising from or related to that order and ten thousand US dollars (US $10,000) for all claims not part of any particular order. 16. Governing Law and Dispute Resolution 16.1 This Contract shall be governed by and construed in accordance with the laws of (i) the State of New York if Buyer’s place of business is in the U.S. or (ii) England if the Buyer’s place of business is outside the U.S., in either case without giving effect to any choice of law rules that would GEP387M 09/11 • Prices and data subject to change without notice. 6.13 Terms the hazardous conditions. In such an event, Buyer shall eliminate the hazardous conditions in accordance with applicable laws and regulations so that Seller’s work under the Contract may safely proceed, and Seller shall be entitled to an equitable adjustment of the price and schedule to compensate for any increase in Seller’s cost of, or time required for, performance of any part of the work. Buyer shall properly store, transport and dispose of all Hazardous Materials introduced, produced or generated in the course of Seller’s work at the Site. General Information Form ES 104 (Rev. 4) Terms and Conditions for Sale of Products and Services Terms Other Application Information Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Form ES 104 (Rev. 4) cause the application of laws of any other jurisdiction (the “Governing Law”). If the Contract includes the sale of Products and the Buyer is outside the Seller’s country, the United Nations Convention on Contracts for the International Sale of Goods shall apply. 16.2 All disputes arising in connection with this Contract, including any question regarding its existence or validity, shall be resolved in accordance with this Article 16. If a dispute is not resolved by negotiations, either party may, by giving written notice, refer the dispute to a meeting of appropriate higher management, to be held within twenty (20) business days after the giving of notice. If the dispute is not resolved within thirty (30) business days after the giving of notice, or such later date as may be mutually agreed, either party may commence arbitration or court proceedings, depending upon the location of the Buyer, in accordance with the following: (a) if the Buyer’s pertinent place of business is in the U.S, legal action shall be commenced in federal court with jurisdiction applicable to, or state court located in, either Cobb County, Georgia or the location of Buyer’s principal place of business; or (b) if the Buyer’s pertinent place of business is outside the U.S., the dispute shall be submitted to and finally resolved by arbitration under the Rules of Arbitration of the International Chamber of Commerce (“ICC”). The number of arbitrators shall be one, selected in accordance with the ICC rules, unless the amount in dispute exceeds the equivalent of U.S. $5,000,000, in which event it shall be three. When three arbitrators are involved, each party shall appoint one arbitrator, and those two shall appoint the third within thirty (30) days, who shall be the Chairman. The seat, or legal place, of arbitration, shall be London, England. The arbitration shall be conducted in English. In reaching their decision, the arbitrators shall give full force and effect to the intent of the parties as expressed in the Contract, and if a solution is not found in the Contract, shall apply the governing law of the Contract. The decision of the arbitrator(s) shall be final and binding upon both parties, and neither party shall seek recourse to a law court or other authority to appeal for revisions of the decision. 16.3 Notwithstanding the foregoing, each party shall have the right at any time, at its option and where legally available, to immediately commence an action or proceeding in a court of competent jurisdiction, subject to the terms of this Contract, to seek a restraining order, injunction, or similar 6.14 www.gemotors.com • 800-541-7191 order to enforce the confidentiality provisions set forth in Article 6 and/or the nuclear use restrictions set forth in Section 19.1, or to seek interim or conservatory measures. Monetary damages shall only be available in accordance with Section 16.2. 17. Inspection and Factory Tests Seller will apply its normal quality control procedures in manufacturing Products. Seller shall attempt to accommodate requests by Buyer to witness Seller’s factory tests of Products, subject to appropriate access restrictions, if such witnessing can be arranged without delaying the work. 18. Software, Leased Equipment, Remote Diagnostic Services, PCB Services If Seller provides any software to Buyer, the Software License Addendum shall apply. If Seller leases any of Seller’s equipment or provides related Services to Buyer, including placing Seller’s equipment at Buyer’s site to provide remote Services, the Lease Addendum shall apply. If Seller provides remote diagnostic services to Buyer, the Remote Diagnostic Services Addendum shall apply. If Seller provides PCB Services to Buyer, the PCB Services Addendum shall apply. If there is any conflict between these “Terms and Conditions for the Sale of Products and Services, Form ES 104” and the terms of any addendum incorporated pursuant to this Article 18, the terms of the addendum shall take precedence with respect to the applicable scope. 19. General Clauses 19.1 Products and Services sold by Seller are not intended for use in connection with any nuclear facility or activity, and Buyer warrants that it shall not use or permit others to use Products or Services for such purposes, without the advance written consent of Seller. If, in breach of this, any such use occurs, Seller (and its parent, affiliates, suppliers and subcontractors) disclaims all liability for any nuclear or other damage, injury or contamination, and, in addition to any other rights of Seller, Buyer shall indemnify and hold Seller (and its parent, affiliates, suppliers and subcontractors) harmless against all such liability. Consent of Seller to any such use, if any, will be conditioned upon additional terms and conditions that Seller determines to be acceptable for protection against nuclear liability. 19.2 Seller may assign or novate its rights and obligations under the Contract, in whole or in part, to any of its affiliates or may assign any of its accounts receivable under this GEP387M 09/11 • Prices and data subject to change without notice. Terms and Conditions for Sale of Products and Services 19.5 The following Articles shall survive termination or cancellation of the Contract: 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 16, 18, 19 and 20. 19.6 The Contract represents the entire agreement between the parties. No oral or written representation or warranty not contained in this Contract shall be binding on either party. Buyer’s and Seller’s rights, remedies and obligations arising from or related to Products and Services sold under this Contract are limited to the rights, remedies and obligations stated in this Contract. No modification, amendment, rescission or waiver shall be binding on either party unless agreed in writing. 20.3 If Buyer is an agency of the U.S. Government, then as permitted by FAR 12.302, Buyer agrees that all paragraphs of FAR 52.212-4 (except those listed in 12.302(b)) are replaced with these Terms and Conditions. Buyer further agrees the subparagraphs of FAR 52.212-5 apply only to the extent applicable for sale of COTS and/or commercial items and as appropriate for the Contract Price. 20.4 If Buyer is procuring the Products or Services as a contractor, or subcontractor at any tier, on behalf of any agency of the U.S. Government, then Buyer agrees that FAR 52.212-5(e) or 52.244-6 (whichever is applicable) applies only to the extent applicable for sale of COTS and/or commercial items and as appropriate for the Contract Price. Motor Pricing Other 19.7 Except as provided in Article 15 (Limitations of Liability) and in Section 19.1 (no nuclear use), this Contract is only for the benefit of the parties, and no third party shall have a right to enforce any provision of this Contract, whether under the English Contracts (Rights of Third Parties) Act of 1999 or otherwise. Modifications Pricing 20.2 Buyer agrees that all Products and Services provided by Seller meet the definition of “commercial-off-the-shelf” (“COTS”) or “commercial item” as those terms are defined in Federal Acquisition Regulation (“FAR”) 2.101. To the extent the Buy American Act, Trade Agreements Act, or other domestic preference requirements are applicable to this Contract, the country of origin of Products is unknown unless otherwise specifically stated by Seller in this Contract. Buyer agrees any Services offered by Seller are exempt from the Service Contract Act of 1965 (FAR 52.222-41). Buyer represents and agrees that this Contract is not funded in whole or in part by American Recovery Reinvestment Act funds unless otherwise specifically stated in the Contract. The version of any applicable FAR clause listed in this Article 20 shall be the one in effect on the effective date of this Contract. Accessories & Modifications 19.4 If any Contract provision is found to be void or unenforceable, the remainder of the Contract shall not be affected. The parties will endeavor to replace any such void or unenforceable provision with a new provision that achieves substantially the same practical and economic effect and is valid and enforceable. 20.1 This Article 20 applies only if the Contract is for the direct or indirect sale to any agency of the U.S. government and/or is funded in whole or in part by any agency of the U.S. government. Outline Dimensions 19.3 Buyer shall notify Seller immediately upon any change in ownership of more than fifty percent (50%) of Buyer's voting rights or of any controlling interest in Buyer. If Buyer fails to do so or Seller objects to the change, Seller may (a) terminate the Contract, (b) require Buyer to provide adequate assurance of performance (including but not limited to payment), and/or (c) put in place special controls regarding Seller’s Confidential Information. 20. US Government Contracts Application Information Contract to any party without Buyer’s consent. Buyer agrees to execute any documents that may be necessary to complete Seller’s assignment or novation. Seller may subcontract portions of the work, so long as Seller remains responsible for it. The delegation or assignment by Buyer of any or all of its rights or obligations under the Contract without Seller’s prior written consent (which consent shall not be unreasonably withheld) shall be void. General Information Form ES 104 (Rev. 4) Terms 19.8 This Contract may be signed in multiple counterparts that together shall constitute one agreement. www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. 6.15 Notes Terms Other Application Outline Dimensions Accessories & Modifications Modifications Pricing Motor Pricing General Information Other Information 6.16 www.gemotors.com • 800-541-7191 GEP387M 09/11 • Prices and data subject to change without notice. Additional Motor Resources www.gemotors.com Visit GE Motors online for additional information regarding the entire product line of GE Motors. For more information on the following and more, check out our motors’ homepage. • Motors Overview • Authorized Service Centers • Parts Distributors • Contact Information • Application Details • Product Line Literature GE Fort Wayne, IN 46802 www.gemotors.com © 2012 General Electric Company. All rights reserved. GEP387M 1/12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2012:01:04 10:57:05-05:00 Creator : Adobe InDesign CS5 (7.0.4) Modify Date : 2013:02:14 08:02:28-05:00 Trapped : False Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2013:02:14 08:02:28-05:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Format : application/pdf Document ID : uuid:a318a656-f9d1-9149-b66d-5b4871be1921 Instance ID : uuid:dbc5a10d-6027-4f6d-a488-903cddd37306 Producer : Adobe PDF Library 9.9 Page Count : 180EXIF Metadata provided by EXIF.tools