PRO 3000 CPE Quick Installation Guide  - 1 - This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the CPEs Product Manual. Package Content Check that the package contains:   PRO 3000 ODU   Crossed Ethernet cable with two RJ-45 connectors for connecting the NG_VG power injector to a PC/HUB/switch.  Sealing cap  Pole mounting kit Additional Equipment and Tools required for Installation   Indoor-to-outdoor Category 5E PoE Ethernet cable with two shielded RJ-45 connectors (can be ordered separately) and an RJ-45 connectors crimping tool.   Mains plug adapter or termination plug (if the power plug on the supplied AC power cord does not fit local power outlets).   Sealing materials: mastic tape (Scotchfil™ Electrical Insulation Putty), Cold Shrink sealing kit.  WARNING:   ONLY experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities should install outdoor units and antennas. Failure to do so may void the product warranty and may expose the end user or Service Provider to legal and financial liabilities. The manufacturer and its resellers or distributors are not liable for injury, damage or regulation violations associated with the installation of outdoor units or antennas. Equipment Location Guidelines Select the optimal locations for the equipment using the following guidelines: 1.  The antenna should provide a direct, or near line of sight, with the Base Station antenna. The higher the placement of the antenna, the better the achievable link quality. The location of the ODU should enable easy access to the unit for installation and testing.  2.  The indoor equipment should be installed as close as possible to the location where the indoor-to-outdoor cable enters the building. The location of the indoor equipment should be selected taking into account its connection to a power outlet and the end-user’s data equipment. (The length of the IDU-to-ODU cable, together with the length of the cable connecting the IDU to the data equipment, should not exceed 100m). ODU Installation Mounting the ODU Mount the ODU unit on a 1"-4" pole using the supplied kit: 1.  With the connector facing downward, attach the bracket to the two designated holes at the back of the ODU, as shown in Figure 1. Use the two M5*16mm bolts and spring washers. (Figure 1) 2.  Thread the M8*40mm bolt through a spring washer and a flat washer and then through the bracket hole. (Figure 2) 3.  Thread the M5*35mm bolt through the designated hole in the bracket. (Figure 2) 4.  Attach the clamp to the bracket such that the bolt is threaded through it and tighten using an M8 nut. Make sure the bracket is secured tightly. (Figure 3) 5.  Attach the ODU to a 1" -4" pole. Attach the clamp to the other side of the pole. Thread the M8*100mm bolts through both clamp holes on either side using spring washers. Tighten the bolts using nuts and spring washers. (Figure 4)     Figure 1  Figure 2  Figure 3 ODU M8*40mm boltBracket Clamp M5*35 bolt M5*16mm Bolt M8 nut P/N: 215805
PRO 3000 CPE Quick Installation Guide  - 2 -     Figure 4   6.  Connect a grounding cable between the Ground terminal of the ODU (marked      ) and a good ground connection. Preparing the IDU-ODU Cable Use a crimp tool for RJ-45 connectors to prepare the wires. Insert them into the appropriate pins and use the tool to crimp the connector. Make sure to do the following:   Remove as small a length as possible of the external jacket. Verify that the external jacket is well inside the sealing cover when connected to the unit, to ensure good sealing.   Pull back the shield drain wire before inserting the cable into the RJ-45 connector, to ensure a good connection with the connector's shield after crimping. The following diagram shows the required wire pair pin-to-pin connections, including the color codes used in cables supplied by the manufacturer.  Wire color Pin Blue 1 Blue/white  2 Orange 3 Orange/white 6 Brown  4 Brown/white  5 Green 7 Green/white 8 123456781 + 2 4 + 57 + 83 + 6P/N: 215805     Connecting and Sealing the IDU-ODU Cable For increased weather protection, use high quality sealing material such as Scotchfil™ Electrical Insulation Putty from 3M (or equivalent), over-wrapped with a UV resistant outdoor rated tape (e.g. Super 33+ or Super 88 vinyl Electrical Tape). To seal the connector, use high quality cold shrink sleeves.  1.  Cut the cold shrink sleeve to size. Take into account the size of the unit’s connector and additional 2.5 cm (0.5 in.). 2.  Slide the cold shrink sleeve onto the cable before connecting the cable. 3.  Follow the detailed instructions supplied with the sealing cap to assemble the sealing cap onto the cable:   Sealing Components
PRO 3000 CPE Quick Installation Guide  - 3 - a.  Strip the cable sheath. b.  Insert the screw nut into the housing.   c.  Insert the seal at the back end of the housing.  d.  Insert the cable all the way through.   e.  Crimp the RJ-45 plug  f.  Insert the plug into the housing. Secure the sealing nut in place.   g.  Stricken the gasket on the front end of the housing.  h.  Secure the screw nut (C) in place.    4.  Connect the Ethernet cable to the RJ-45 connector of the ODU. Make sure that the connector is completely inserted and tightened. 5.  Attach the mastic tape (Scotchfil™ Electrical Insulation Putty) and wrap it around the connector butting up against the connector. Do not over stretch. 6.  Squeeze to tighten the mastic sealer. Make sure there are no air bubbles. 7.  Slide the cold shrink sleeve on top of the connector. Make sure that the sleeve covers both cable connector and unit connector.      Figure 4 Cold Shrink Tubing Cold Shrink Sleeve  Cold Shrink Seal Cord  8.  Pull the cord slowly to shrink the sleeve. 9.  Route the cable to the location selected for the indoor equipment. 10.  Assemble an RJ-45 connector with a protective cover on the indoor end of the IDU-ODU cable. Refer to the pin assignment and color codes in standard cables described above.  NG_VG Installation  WARNING:   Make sure to use the PoL-PoE adapter. Failing to do so may damage the equipment.  Note:   It is assumed that the installation and configuration of the PRO 3000 CPE has already been completed, and that the NG_VG was preconfigured by the operator. 1.  Connect the PoL-PoE adapter to the NG_VG WAN port.  2.  Place the NG_VG on a desktop or shelf. The location should be selected taking into account the Equipment Location Guidelines above.  3.  Connect the mains power cord to the power supply. Connect one end to the 48 VDC jack on the rear panel of the NG_VG. Connect other end to the AC mains. P/N: 215805
PRO 3000 CPE Quick Installation Guide  - 4 - P/N: 215805   4.  Connect one end of the straight Ethernet cable (8P8C) to the PoL-PoE adapter.  5.  Connect the other end to the LAN port of the PRO 3000 CPE. For more information refer to the NG_VG Quick Installation Guide. Basic Configuration Using the Web Configuration Server 1.  Use the Web Configuration Server to configure the basic parameters. 2.  Connect a PC/Notebook to the LAN port of the NG_VG, using the supplied Ethernet cable. 3.  Ensure that the NG_VG has a WAN Data Service configured with NAT enabled and with all NG_VG LAN ports grouped to it (Refer to the NG-VG manual for details).  4.  By default, the CPE has a DHCP server enabled. In this case, ensure that the NG_VG WAN Data Service is configured to receive its IP by DHCP from the CPE.  If the DHCP server of the CPE is disabled, for the WAN Data Service on the NG_VG you can manually set a static IP address, netmask, and gateway according to your CPE model (refer to the table below): Table 1: Connectivity Parameters  Model Name  Basic Connectivity Parameters 4M-K2-CPE-Si-1D-2.5 4M-CPE3000-PRO-1D-2.3 4M-K2-CPE-PRO-ODU-1D-2.5 4M-K2-CPE-PRO-ODU-1D-3.3 4M-CPE3000-PRO-1D-3.6 IP address: 192.168.254.x, 1 < x < 253, excluding 251 Netmask: 255.255.255.0 Gateway: 192.168.254.251 4M-CPE3000-PRO-1D 3.4-3.7 IP address: 192.168.209.x, 2 < x < 253 Netmask: 255.255.255.0 Gateway: 192.168.209.1  5.  From a PC connected to the NG_VG open a web browser, and connect to http:// 192.168.254.251/. The Login page is displayed. Enter the user name and password and click Login. 6.  Configure the parameters, as needed. 7.  Reset the unit to apply the changes.  Using the Auto-configuration Tool 1.  Connect a PC/Notebook to the LAN port of the NG_VG, using the supplied Ethernet cable. 2.  Ensure that the NG_VG has a WAN Data Service configured with NAT enabled and with all NG_VG LAN ports grouped to it (Refer to the NG_VG manual for details). Also, ensure that the NG_VG WAN Data Service is configured to receive its IP by DHCP from the CPE.  3.  Switch on the CPE and wait until the NG_VG Data service connection receives an IP. 4.  From the CDROM supplied with the unit, run the CPE Auto Configuration Tool: CPEAutoConfigTool.exe; The Installation Setup Wizard window is displayed. 5. Click Next to continue; The Choose Your ISP window is displayed. 6.  Choose the ISP (Internet Service Provider) ConfigFile from the list and click Next. The Ready To Install window is displayed. 7. Click Install. The tool starts the auto-configuration process of the CPE settings. It will change default configuration by using the *.CONF file, and then run “reset to factory default” by using default configuration in the file. 8.  When the installation is complete, click Finish. The CPE is now configured with the parameters from the ConfigFile. Aligning the ODU's Antenna 1.  Point the ODU toward the general direction of the serving BTS. 2.  Verify that the unit is synchronized with a BTS. If the SU is not synchronized with a BTS, ensure that all parameters are configured properly. If the unit is still not synchronized with a BTS, improve the quality of the link by changing the direction of the ODU or by placing the ODU at a higher or in an alternate location. 3.  Ensure that the front of the ODU is always facing the location of the BTS. However, in certain conditions, such as when the line of site to the BTS is hampered, better reception may be achieved using a reflected signal. In this case, the ODU is not always directed toward the BTS. 4.  Secure the unit firmly to the pole. Verifying Proper Operation 1.  Verify data connectivity by sending a ping command to the BTS or by connecting to the Internet. 2.  To verify proper operation of the SU, examine the LED indicators on the NG_VG:
PRO 3000 CPE Quick Installation Guide  - 5 - Table 2: NG_VG LEDs Name  Description  Functionality WAN  WAN Port Status Indication   Off: Wired interface not established (Ethernet connection not detected).   Blinking: Traffic is passing through.   On: Wired interface established (Ethernet connection detected).  Radio Frequency Interference Statement This equipment has been tested and found to comply with RSS-197 and RSS-192 of the Industry Canada Rules (for 3.x GHz bandwidth) and the limits for a class B digital device, pursuant to ETSI EN 301 489-1 and Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment notwithstanding use in commercial, business and industrial environments. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Radiation Hazard Warning To comply with FCC RF exposure requirements in Section 1.1307 and 2.1091 of FCC Rules, the antenna used for this transmitter must be kept at a separation distance of at least 50 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. R&TTE Compliance Statement This equipment complies with the appropriate essential requirements of Article 3 of the R&TTE Directive 1999/5/EC. Disposal of Electronic and Electrical Waste  Disposal of Electronic and Electrical Waste  Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted waste. Please contact your local recycling authority for disposal of this product.  P/N: 215805