GemTek Technology WLTMS11041 LTE Cat 6 Single-Mode Outdoor CPE User Manual

Gemtek Technology Co., Ltd. LTE Cat 6 Single-Mode Outdoor CPE Users Manual

Users Manual

Download: GemTek Technology WLTMS11041 LTE Cat 6 Single-Mode Outdoor CPE User Manual
Mirror Download [FCC.gov]GemTek Technology WLTMS11041 LTE Cat 6 Single-Mode Outdoor CPE User Manual
Document ID3311859
Application IDZGTWLGlcQQeVa5EbHd2k+w==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize82.29kB (1028633 bits)
Date Submitted2017-03-10 00:00:00
Date Available2017-03-14 00:00:00
Creation Date2017-12-25 12:42:44
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-25 12:42:44
Document TitleUsers Manual
Document CreatorMicrosoft® Office Word 2007

LTE CPE
Quick installation Guide
WLTMS-110_384041
Connection Guide
Copyright
This DOCUMENT is copyrighted with all rights reserved. No part of
this publication may be reproduced, transmitted, transcribed, stored in
a retrieval system, or translated into any language in any form by any
means without the written permission of Gemtek Technology Co. Ltd.
Notice
Gemtek reserves the right to change specifications without prior
notice.
While the information in this document has been compiled with
great care, it may not be deemed an assurance of product
characteristics. Gemtek shall be liable only to the degree specified in
the terms of sale and delivery.
The reproduction and distribution of the documentation and
software supplied with this product and the use of its contents is
subject to written authorization from Gemtek.
Connectors
1. One RJ-45 connector for connecting to the PoE adaptor.
2. LED indicator inside and SIM card slot for inserting SIM card.
3. A grounding screw on the rear panel.
LED Indicators _ODU
LED name
LED List
MAIN power
Ethernet
status
SIM status
Location
Color
LTE 2
LTE 3
Status Indication
●●●
●●●
●○○
○○○
○●○
○○○
○○●
○○○
Blue
○○○
●○○
○○○
●●○
○○○
●●●
ON
Power On
OFF
Power Off
Yellow Steady ON
Green
LTE Status LED : Link Status
LTE 1
LED Behavior
Red
Ethernet Connected
Blinking
Data Transmission
OFF
No Ethernet action
Steady ON
SIM Detected
Blinking when
On-hook
PUK / PIN Code
OFF
No SIM Detected
When CPE is power on, each LED
indicates each link status
Steady ON
Red/
Steady ON
Yellow
Red/
Yellow/ Steady ON
Green
CINR < 8dB
8dB < CINR <
15dB
15dB < CINR
Installing LTE outdoor CPE
●
Selecting a Location: LTE Outdoor CPE should be pole-mounted
outdoors and aligned so its antenna faces the nearest LTE eNB.
When selecting a suitable location for the unit, consider these
guidelines:
•
Place LTE Outdoor CPE as high as possible to achieve the best
possible link quality.
•
Place the LTE Outdoor CPE away from power and telephone
lines.
•
Avoid placing LTE Outdoor CPE too close to any metallic
reflective surfaces.
•
Be sure to ground LTE Outdoor CPE with an appropriate
grounding wire (not included) by attaching it to the grounding
screw on the unit and to a good ground connection.
●
Mounting the ODU: Mount LTE Outdoor CPE on a 1”-4” pole
using the supplied kit, or the optional tilt accessory.
•
Using the clamp
1. Thread the M10*100mm bolt through a spring washer, flat
washer and the bracket holes.
2. With the connector facing downward, attaché LTE Outdoor
CPE to a 1”-4” pole.
3. Attach the bracket to the other side of the pole.
4. Thread the M10*100mm bolts through both holes on either
side, and tighten the nuts.
Connecting the Cables
●
Outdoor Connection: Connect a grounding cable between the
Ground terminal of the LTE outdoor CPE and a good ground
connection.
●
Preparing and connecting the cable: Use only UTP-FTP
4x2x24AWG CAT. 5E outdoor cable from an approved
manufacturer. The cable provides pin-to-pin connection on both
ends.
1. Prepare the cable: Use a crimp too for RJ-45 connectors to
prepare the wires. Insert them into the appropriate pins and
use the tool to crimp the connector. Make sure to do the
following:
•
Remove as small a length as possible of the external jacket.
Verify that the external jacket is well inside the sealing
cover when connected to the unit, to ensure good sealing.
•
Pull back the shield drain wire before inserting the cable into
the RJ-45 connector, to ensure a good connection with the
connector’s shield after crimping.
The following figure shows the required wire pair connections.
The color codes used in standard cables supplied by the
manufacturer are as listed in the table.
2. Connect the cable
• Remove the sealing cable gland plug from the gland nut.
• Open the sealing gland nut and remove it. Don not
disassembles the gland base from the bracket.
• Insert the cable into the sealing gland base and connect it to
the RJ-45 connector at the bottom of the CPE. Make sure the
connector is completely inserted and tightened.
• Insert the rubber bushing on the cable into the gland base.
• Tighten the gland nut. Use the dedicated tool for fastening
the sealing glands.
3. Seal the connector
• Attach the mastic tape (ScotchfilTM Electrical Insulation Putty)
and wrap it around the connector butting up against the
connector. Do not over stretch.
• Squeeze to tighten the mastic sealer. Make sure there are no
air bubbles.
• Slide the cold shrink sleeve on top of the connector. Make
sure that the sleeve covers both cable connector and unit
connector.
• Pull the cord slowly to shrink the sleeve.
●
Indoor Connection
1. It is assumed that the RJ-45 is already connected to the LTE
outdoor CPE. Assemble an RJ-45 connector with a protective
cover on the other end of the LTE outdoor CPE cable.
2. Connect the other end of the cable from ODU to the PoE
adaptor which labeled “POE”.
3. Connect RJ45 cable from PoE adaptor which label “LAN” to a
PC/NB/Hub/Switch.
Web Interface
Please follow the steps below to configure your device through the
web interface:
Step1:
Open the Web browser (Internet Explorer) and enter the
default IP address of the ODU CPE, which is :
http://192.168.15.1
Web browser
Step2:
Enter ODU administrator login username/password to access
the web management interface. The default
username/password is administrator/administrator.
Web management interface
Step3:
The page shown here gets displayed in your browser after
login; you can now configure the device settings.
GUI Interface
Mode:
LTE
Operator: APN Name
Signal:
(More bar means better
signal)
(Disconnect, no signal)
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 23 cm between the radiator & your body.
Professional installation instruction
Please be advised that due to the unique function supplied by this product, the
device is intended for use with our interactive entertainment software and
licensed third-party only. The product will be distributed through controlled
distribution channel and installed by trained professional and will not be sold
directly to the general public through retail store.
1. Installation personal
This product is designed for specific application and needs to be installed
by a qualified personal who has RF and related rule knowledge. The
general user shall not attempt to install or change the setting.
2. Installation location
The product shall be installed at a location where the radiating antenna
can be kept 23cm from nearby person in normal operation condition to
meet regulatory RF exposure requirement.
3. External antenna
Use only the antennas which have been approved by the applicant. The
non-approved antenna(s) may produce unwanted spurious or excessive
RF transmitting power which may lead to the violation of FCC limit and is
prohibited.
4. Installation procedure
Please refer to user’s manual for the detail.
5. Warning
Please carefully select the installation position and make sure that the final
output power does not exceed the limit set force in relevant rules. The
violation of the rule could lead to serious federal penalty.
Instructions d'installation professionnelle
Veuillez noter que l'appareil etant dedie a une fonction unique, il doit etre utilise
avec notre logiciel proprietaire de divertissement interactif . Ce produit sera
propose par un reseau de distribution controle et installe par des professionels; il
ne sera pas propose au grand public par le reseau de la grande distribution.
1. Installation
Ce produit est destine a un usage specifique et doit etre installe par un
personnel qualifie maitrisant les radiofrequences et les regles s'y rapportant.
L'installation et les reglages ne doivent pas etre modifies par l'utilisateur final.
2. Emplacement d'installation
En usage normal, afin de respecter les exigences reglementaires concernant
l'exposition aux radiofrequences, ce produit doit etre installe de facon a
respecter une distance de 23cm entre l'antenne emettrice et les personnes.
3. Antenn externe.
Utiliser uniiquement les antennes approuvees par le fabricant. L'utilisation
d'autres antennes peut conduire a un niveau de rayonnement essentiel ou non
essentiel depassant les niveaux limites definis par FCC, ce qui est interdit.
4. Procedure d'installation
Consulter le manuel d'utilisation.
5. Avertissement
Choisir avec soin la position d'installation et s'assurer que la puissance de
sortie ne depasse pas les limites en vigueur. La violation de cette regle peut
conduire a de serieuses penalites federales.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a6179ba0-9f46-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:12 17:46:57Z
Create Date                     : 2017:07:12 17:46:57Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:a6179ba0-9f46-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MXF-WLTMS11041

Navigation menu