Geophysical Survey Systems D50300800 Ground Penetrating Radar Antenna User Manual

Geophysical Survey Systems, Inc. Ground Penetrating Radar Antenna Users Manual

Users Manual

Copyright © 2012 Geophysical Survey Systems, Inc. MN72-489 Rev - All Rights Reserved UtilityScanTM DF Quick Start Guide A Fast Check List For Field Operation   Section 1: Getting Started.................................................................................................................................... 2 Keyboard Capability ............................................................................................................................................... 2 ToughBook Information ....................................................................................................................................... 3 Standard Icons ......................................................................................................................................................... 4 Display Channel (Frequency) Icons .................................................................................................................. 4 Powering and Booting Up ................................................................................................................................... 5 Powering Down ....................................................................................................................................................... 7 Section 2: Playback Only, New Project, and Last Project Modes ............................................................ 8 Playback Only Mode .............................................................................................................................................. 8 New Project Mode and Last Project Mode ................................................................................................. 20 Collecting Data ..................................................................................................................................................... 32 Appendix A: Cart and Antenna Assembly Instructions............................................................................ 35 Appendix B: Battery Charger Information .................................................................................................... 42 Appendix C: Dielectrics of Common Materials (Soil Conditions) ......................................................... 43 Appendix D: Examples of Some Common Objects ................................................................................... 44 Appendix E: Glossary of Terms ......................................................................................................................... 49
  Limited Warranty, Limitations Of Liability And Restrictions Geophysical Survey Systems, Inc. hereinafter referred to as GSSI, warrants that for a period of 24 months from the delivery date to the original purchaser this product will be free from defects in materials and workmanship. EXCEPT  FOR THE FOREGOING LIMITED WARRANTY, GSSI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. GSSI's obligation is limited to repairing or replacing parts or equipment which are returned to GSSI, transportation and insurance pre-paid, without alteration or further damage, and which in GSSI's judgment, were defective or became defective during normal use. GSSI ASSUMES NO LIABILITY FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES CAUSED BY PROPER OR IMPROPER OPERATION OF ITS EQUIPMENT, WHETHER OR NOT DEFECTIVE. Before returning any equipment to GSSI, a Return Material Authorization (RMA) number must be obtained. Please call the GSSI Customer Service Manager who will assign an RMA number. Be sure to have the serial number of the unit available Regulatory Information Please see the GSSI Manual CD or our website, www.geophysical.com/regulatoryinformation.htm, for current information and FCC Registration Form, including: • FCC Notice for U.S. Customer • Canadian Requirements for RSS-220 • Declaration of CE Conformance
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  1 All Rights Reserved UtilityScanTM DF         3 2 1 1Control Unit (ToughBook H2) 22.0 m Control Cable 34 Wheel Cart 4Foam Insert and Dual Frequency Antenna with battery inside the Capsule 4
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  2 All Rights Reserved Section 1: Getting Started Keyboard Capability The Panasonic CF-H2 ToughBook is designed to be used as a touch screen. You may use your fingers to tap on an icon or menu option, or you may use the attached stylus pen. There is also keyboard capability on the screen of the ToughBook. A keyboard “Tab” is located at the top left side of the screen. You may tap on the tab and a full keyboard will slide to the middle of the screen. At times, when data input (typing) is needed, you may simply tap on the white area of the screen where text and/or numbers may be input. A small keyboard will appear on the screen. Tap on the small keyboard and a large keyboard is displayed. Simply tap on the appropriate keys and tap Return    when you are done. You may exit the keyboard by tapping on the “X” located on the upper right hand corner of the keyboard.      Small Keyboard
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  3 All Rights Reserved ToughBook Information • The lights under the battery (1 and 2) indicate how much power is left in each battery. The lights will be green, yellow and red. • A battery may be replaced while the system is on. The system will run off of one battery while the other one is being replaced.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  4 All Rights Reserved Standard Icons There are icons that will perform the same function throughout the system. They are as follows: •          Change values up or down, or highlight menu options or files. •          Accept the value. •          Test the value. •          Cancel. The icons will display as red  or white,  depending upon whether or not it was the most recent selected option.  Display Channel (Frequency) Icons These icons will indicate what type of display is on the screen. Also, by tapping on them, will change the display accordingly • High Frequency (800 mhz) • Low Frequency (300 mhz) • Blend • All Three
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  5 All Rights Reserved Powering and Booting Up 1 Assemble the cart as shown in Appendix A: Cart Assembly Instructions. Important: Antenna battery must be attached to the antenna before continuing to Step 2. 2 To power up the system: a) Press and hold the power button on the ToughBook for about 2 seconds until a green light illuminates above the power button. A green light will blink on the antenna during the system boot up. It will be off when the boot up process is complete. This green light will illuminate when communication is re-established. b) After a few seconds, when the system boot up is complete, the UtilityScan DF Start Screen is displayed. c) Tap either: • A1 Icon or press the A1 button to start. • A5 Icon or press the A5 button to update system software.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  6 All Rights Reserved 3 Select (by tapping) one of three Modes: • Playback Only: To playback data previously collected and saved. • New Project: To configure and collect data for a new project. • Last Project: Collect data using the same configuration as the last project. Note: If there is no communication between the ToughBook and the antenna, or there is no antenna attached to the ToughBook, “New Project” and “Last Project” will display as “No Antenna Found”. The green light on the antenna will illuminate if communication is established.      Communication Established with Antenna No Communication Established with Antenna
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  7 All Rights Reserved Powering Down It is essential that these steps are followed in order when powering down the system.  Failure to do so may result in boot-up issues*. 1 Tap on System Options. 2 Tap on System Shutdown. 3 Tap either: • Exit: Close Application to return to start screen. At this point, press and hold the power button for about 3 seconds.  The system will shut down properly. • Power Off: Close Application and turn OFF System power.  The system will automatically shut down. (Recommended)  * If the system was not powered down properly and before the next time you power up, you must remove and disconnect the battery on the antenna, the re-connect it. This will turn the antenna off, then back on. You can now power up normally.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  8 All Rights Reserved Section 2: Playback Only, New Project, and Last Project Modes Playback Only Mode The Playback Only mode allows you to view and edit data previously collected and saved.  After selecting Playback Only, select which file you would like to review:  a) Tap on the arrows to highlight a file. b) Tap on the Select Icon to select or de-select a file. c) Tap on the Accept Icon. You will see the data in the O-Scope view change as if the data is scrolling across the screen. You may stop the scrolling by tapping on the Stop Icon (This will toggle between Stop Icon and Preview File Icon. The Preview File Icon will continue the scrolling). The Screen is divided into three sections: Data View (O-Scope), Main Menu located at the right pane of the screen, and the Sub-Menu located at the bottom of the screen.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc.  9 All Rights Reserved A Status screen located at the lower left corner of the screen. They indicate:  • GPS Status. • Disk Space Used (storage space). • Battery Power remaining for the antenna. • Battery Power remaining for the ToughBook.  The Data View screen will display data in any one of the follow views: • High Frequency • Low Frequency • Blend • All Three (Default) You may display just one frequency at a time by tapping the icon at the top of the O-Scope. Tapping the same icon will display all three modes again. When changing displays, you must tap the Preview File icon  to re-display the O-Scope data.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 10 All Rights Reserved High, Low, Blend, and Active Frequency Symbols    High Frequency Low Frequency Blend Active Display
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 11 All Rights Reserved    Low Frequency Display High Frequency Display Blend Display Both Frequencies plus Blend
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 12 All Rights Reserved Main Menu Options (Right Pane of the Screen)  Scan Process Icon • Scan • Dielectric Constant: Enter the Dielectric of the soil (See Appendix C for more Dielectric information). • Soil Type: Determine the soil conditions. This will change the Dielectric Value. • Gain Settings • Gain Mode • Auto allows the system to configure the Gain. • Manual allows the user to configure the Gain. • Number of Points (Only if Gain Mode is set to Manual) • Number of points or “Individual Sections” to adjust the Gain. • Ranges for 1 point to 8 points. • GP1: 8 (Only if Gain Mode is set to Manual) • Depending upon number of Gain Points, adjust each section accordingly. • Values range from -42 to 126. Note: Tap on the double arrows (up or down) to display the appropriate gain points.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 13 All Rights Reserved • Filters (See Appendix E for more information) • Stacking: To reduce random or high frequency noise in your data. • Background Removal: Remove horizontal banding in your data. • Noise Indicator • On: Display approximately the depth where data becomes too weak. • Off: Turn off display.               High Frequency Noise (Fuzziness) Example Horizontal Banding Example Noise Indicator Example
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 14 All Rights Reserved Output Options Icon • Display:  • Color Table: Select a color scheme. • Color Xform: Select how to distribute the color scheme throughout the scale (bar is negative to positive). • Dual Channel • Split: both channels to be displayed separately. • Blend: both channels are blended together. • Vertical Scale • Equal: Scales are equal. • Real: Scales are set to scale as per antenna depth range.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 15 All Rights Reserved • Manage Files:  • Data Path: Change the Data Path where you would like the data to be written or opened from. • Copy to USB Device: Copies the data from the Data Path to the USB device. • Move to USB Device: Copies the data from the Data Path AND DELETES those files from the ToughBook. • Delete Files: Delete files from the ToughBook. • Units/Scale:  • Depth Scale • Depth: Display the Scale in distance units. • Time: Display the Scale in time units. • Depth Units: Select the unit of measurement for depth or the vertical scale. • Ticks per Unit: Number of ticks for marking the data (short line). • Ticks per Major Unit: Number of ticks for each major unit (long line).
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 16 All Rights Reserved System Options Icon • System Shut Down • Exit: Close Application and Return to Start Screen. • Power Off: Close Application and Shut Down the System (power off) . • Return to Application: Discard Shutdown Request and Return to Setup Screen. • Versions: Displays Version Numbers of the software and firmware • User Interface • Language: Set Language. • Button Design • Label: Text Icons. • Symbol: Pictured Icons. • Brightness Up or Down: Set contrast up or down.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 17 All Rights Reserved  Sub Menu Options (Bottom Pane of the Screen) • Preview File/Stop: Preview file. This will toggle between Preview File and Stop.  • Reset Gain: Reset the display gain for optimal viewing. • Select File: Select another file to playback. • Playback File(s): Display the RADAR data in whatever display you selected as a display (High, Low, or Blend). See next section for options on this screen. • Collect Mode: This will take you to collect mode if you wish to collect data. • File Info: Information about the file.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 18 All Rights Reserved Playback File(s) Options Depending upon the type of display you selected in the previous screen, the data will display in the same mode (High, Low, or Blend) Displayed at the top of the screen: • The name of the file. • The location of the cross hair (X for distance, Z for depth). Place the stylist pen on the screen to move the cross hair to the desired position. Menu Options at the Bottom of the Screen • Cursor Left: Scroll the data towards the beginning of the file. • Cursor Right: Scroll the data towards the end of the file.  • Mark: Mark the data for reference points. a) Place the stylist pen on the screen. b) Move the pen around and place the vertical line where you would like the mark to be placed. c) Tap the Mark Icon.    In this example, the Noise Indicator is turned on, as indicated by the green shaded area.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 19 All Rights Reserved • Stop Playback: Return to the Main Playback Screen. • Set Depth: Indicate a known depth in your data. This will update the dielectric value accordingly. a) Place the stylist pen on the screen. b) Move the pen around and place the horizontal line on the known depth. c) Tap the Set Depth Icon. d) Enter and accept the known depth.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 20 All Rights Reserved New Project Mode and Last Project Mode • New Project Mode will allow you to configure the system as desired for a new project or continue with an old project. • Last Project Mode will bypass the Folder selection screen and continue with the last project with all its settings from the last project. In this mode, you still can make changes to the settings. • In either mode, the options are the same.  After selecting New Project, select which folder you would like to save your data, or create a new folder for a new project.  You may do one of the following: a) Tap on the arrows and select a folder (project. All files save will be saved to this folder and the name of the files will be folder name + a sequential number. Tap on Accept to the continue. b) Tap on New Data Path to create a new folder (project). • Enter and save the new folder (project) name. • Highlight the new folder (project) by tapping on the arrows. • Tap on Accept to continue.  c) Tap on Cancel. The files will be saved to the last folder that was used.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 21 All Rights Reserved d) Once you have selected a folder, the following screen is displayed or you selected Last Project Mode:  The Screen is divided into three sections: Data View (O-Scope), Main Menu located at the right pane of the screen, and the Sub-Menu located at the bottom of the screen
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 22 All Rights Reserved    Low Frequency Display High Frequency Display Blend Display Both Frequencies plus Blend
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 23 All Rights Reserved Main Menu Options (Right Pane of the Screen)  Scan Process Icon • Scan • Depth Range: Enter the depth penetration. • Dielectric Constant: Enter the Dielectric of the soil (See Appendix C for more Dielectric information). • Soil Type: Determine the soil conditions. This will change the Dielectric Value. • Scan Density: Set number of scans per unit (meter or feet). • High (100 scans/m, 30 scans/ft) • Normal (50 scans/m, 15 scans/ft) • AutoSave File • Off: User is prompted to save a file. • On: System will automatically save a file.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 24 All Rights Reserved • Gain Settings • Gain Mode • Auto allows the system to configure the Gain. • Manual allows the user to configure the Gain. • Number of Points (Only if Gain Mode is set to Manual) • Number of points or “Individual Sections” to adjust the Gain. • Ranges for 1 point to 8 points. • GP1: 8 (Only if Gain Mode is set to Manual) • Depending upon number of Gain Points, adjust each section accordingly. • Values range from -42 to 126. Note: Tap on the double arrows (up or down) to display the appropriate gain points.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 25 All Rights Reserved • Filters (See Appendix E for more information) • Stacking: To reduce random or high frequency noise in your data. • Background Removal: Remove horizontal banding in your data. • Noise Indicator • On: Display approximately the depth where data becomes too weak. • Off: Turn off display.            High Frequency Noise (Fuzziness) Example Horizontal Banding Example Noise Indicator Example
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 26 All Rights Reserved • Maintenance • Calibrate SW: Select this option to calibrate the survey wheel. a) Enter Calibration Distance. b) Position Antenna on Start Mark. c) Tap on Start. d) Move Antenna to End Mark. e) Tap on Accept. • Configure GPS: Select this option to configure this system with your GPS. • Set Time: Select this option to set Date and Time.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 27 All Rights Reserved Output Options Icon • Display:  • Color Table: Select a color scheme. • Color XForm: Select how to distribute the color scheme throughout the scale (bar is negative to positive). • Dual Channel • Split: Both channels to be displayed separately. • Blend: Both channels are blended together. • Vertical Scale  • Equal: Scales are equal. • Real:Scales are set to scale as per antenna depth range.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 28 All Rights Reserved • Manage Files:  • Data Path: Change the Data Path where you would like the data to be written or opened from. • Copy to USB Device: Copies the data from the Data Path to the USB device. • Move to USB Device: Copies the data from the Data Path AND DELETES those files from the ToughBook. • Delete Files: Delete files from the ToughBook. • Units/Scale:  • Depth Scale • Depth: Display the Scale in distance units. • Time: Display the Scale in time units. • Depth Units: Select the unit of measurement  for Depth or the vertical scale. • Ticks per Unit: Number of ticks for marking the data (short line). • Ticks per Major Unit: Number of ticks for each major unit (long line).
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 29 All Rights Reserved System Options Icon • System Shut Down • Exit: Close Application and Return to Start Screen. • Power Off: Close Application and Shut Down the System (power off). • Return to Application: Discard Shutdown Request and Return to Setup Screen. • Versions: Displays Version Numbers of the software and firmware • User Interface • Language: Set Language. • Button Design • Label: Text Icons. • Symbol: Pictured Icons. • Brightness Up or Down: Set contrast up or down • Save Setup: Save a current configuration for future use. • Recall Setup: Recall a saved configuration.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 30 All Rights Reserved  Sub Menu Options (Bottom Pane of the Screen) • Stop/Preview Scan: This will turn the antenna off and on. This will toggle between Off and On.  • Reset Gain: Reset the display gain for optimal viewing. • Active Channel: Display between the following modes. • High Frequency • Low Frequency • Blend • Start Scan: Begin collect of data. • Playback Mode: This will take you to playback mode if you wish to view saved data. • File Info: Information about the file. You may also change the file names here as well. All file names will have a sequential number attached to it.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 31 All Rights Reserved Start Scan Options Depending upon the type of display you selected in the previous screen, the data will display in the same mode (High, Low, Split or Blend). Displayed at the top of the screen: • The name of the file. • The display mode. Menu Options at the Bottom of the Screen: • Active Channel: Toggle between High, Low, or Blend frequency displays. • Next File: Save the current file and begin new file.  • Mark: Mark the data for reference points.  • Stop Scan: Save the current file and return to the Main Screen. • Gain: Increase or decrease display gain.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 32 All Rights Reserved Collecting Data • If you plan to save the data you collect, note the file name located at the top left of the screen. • Begin collecting data by moving the cart forward. Data gets collected only when the cart is moving forward. • Once you start seeing hyperbolas on the screen, pull the system straight back along your survey line. You will  see a vertical line (the backup cursor) scroll along your data. When that vertical line is right over the apex of the hyperbola, the center of the antenna is over that target.  • The center of the antenna is located in the middle of the antenna directly under the capsule between the two centerline indicators on each side of the cart. Using these as reference points, mark the ground at each side of your cart. After moving the cart, place an “X” between the two marks. Push the cart straight forward or move the cart to do another line scan. No data will be collected until you have passed the spot where you started to reverse.    Hyperbola which represents a target Vertical Line (Backup Cursor)
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 33 All Rights Reserved Set Depth and Focus Data This will allow you to enter a known depth or migrate the data to re-establish a dielectric value. Note that two icons at the bottom have changed when the backup cursor is displayed on the screen (when the cart was pushed backward. • Set Depth a) Using the stylus pen, place the horizontal line at a known depth. b) Tap Set Depth. c) Input the depth and accept. This will change the dielectric value.   • Focus On a) Using the stylus pen, place the cross-hair on a hyperbola. b) Tap on Focus On. c) Using the stylus pen, match the Focus On hyperbola with a hyperbola on the screen (width). d) Tap on: • Set Focus to accept the hyperbola. This will change the dielectric value. • or Focus Off to cancel this process .
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 34 All Rights Reserved   Blend Mode Display Example Split Mode Display ExampleHigh Frequency Display Example Low Frequency Display Example
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 35 All Rights Reserved Appendix A: Cart and Antenna Assembly Instructions 1 Unpack your system.  • ToughBook H2 and Power Adapter • 2.0 m Communcation Cable • Power Cable, Battery and Charger • Foam Insert • DF Antenna • 4 Wheel Cart with Capsule • CPU Mounting Unit • Manual CD and Quick Start Guide • Battery Chargers for ToughBook and Antenna Batteries • 4 ToughBook batteries • 2 Antenna batteries • Transit case
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 36 All Rights Reserved 2 Assemble the handle to the cart as shown below. Attach the CPU Mounting Bracket and the Cable Guide to the handle. 3 Insert the DF Antenna into the capsule. NOTE THE POSITION and THE DIRECTION of the antenna in the Capsule.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 37 All Rights Reserved 4 Guide the 2.0 m Communication Cable and the Survey Wheel cable through the foam as shown, using the slots of the foam as guides. Attach the cables to the DF antenna as shown. NOTE the service loop of the cables to reduce the tension on the cables.           5 Attach the ToughBook to the mounting bracket.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 38 All Rights Reserved 6 Guide the Green Communication Cable through the cable guide, through the hole at the top of the handle and connect it to the ToughBook.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 39 All Rights Reserved 7 Connect the battery cable and insert the Antenna Battery to the battery mount on the antenna.        8 Place the cover of the capsule, starting in the back as shown. Make certain there is service loop with the cables so that there is no tension with the cables as the capsule moves up and down during data collection. Latch the cover to the lock position.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 40 All Rights Reserved 9 Depending on site conditions and to increase the life of the capsule, you should adjust the height of the capsule by using a strap. Place a ¼ inch piece of plywood under the capsule. Loosen the straps so that the capsule sits on the plywood, then re-tighten the straps.  10 Insert the ToughBook batteries (2), one on each side of the ToughBook.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 41 All Rights Reserved Though the wheels and the capsule come attached to the cart, you may need to unattach and re-attach them. To detach or attach wheels to cart frame. Line up the flat side of the “D” shaped axle rod with the corresponding flat part of the “D” shaped hole on the cart frame. Slide the rod into the cart frame while keeping the blue button at the center of the wheel hub depressed.  Attaching the Capsule to the Cart.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 42 All Rights Reserved Appendix B: Battery Charger Information There are two battery chargers included in your system. • Charger for the Antenna batteries. • Charger for the ToughBook batteries. The cables for each are color coordinated so that cables are used with its corresponding charger. Note: The cable for the ToughBook Battery Charger may also be used directly for the ToughBook as well.           Antenna Battery Charger ToughBook Battery Charger
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 43 All Rights Reserved Appendix C: Dielectrics of Common Materials (Soil Conditions) Material  Dielectric Constant Material Dielectric Constant Air  1  Wet Granite  6.5  Snow Firn  1.5  Travertine  8  Dry Loamy/Clayey Soils  2.5  Wet Limestone  8  Dry Clay  4  Wet Basalt  8.5  Dry Sands  4  Tills  11  Ice  4  Wet Concrete  12.5  Coal  4.5  Volcanic Ash  13  Asphalt  5  Wet Sands  15  Dry Granite  5  Wet Sandy Soils  23.5  Frozen Sand & Gravel  5  Dry Bauxite  25  Dry Concrete  5.5  Saturated Sands  25  Dry Limestone  5.5  Wet Clay  27  Dry Sand & Gravel  5.5  Peats (saturated)  61.5  Potash Ore  5.5  Organic Soils (saturated)  64  Dry Mineral/Sandy Soils  6  Sea Water  81  Dry Salt  6  Water  81  Frozen Soil/Permafrost  6  Syenite Porphyry  6  Wet Sandstone  6
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 44 All Rights Reserved Appendix D: Examples of Some Common Objects  These examples are presented for informational use only. The images that you see on your own site conditions may vary.  Example 1 This piece of data shows a bank of conduits feeding into an industrial building. Note the dipping edge of a trench cut  to the upper left of the conduits.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 45 All Rights Reserved Example 2 This image shows a drain line coming out of a restroom. Also note the mesh at the top of the screen.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 46 All Rights Reserved Example 3 This image shows data collected across a driveway, and locating a conduit from the telephone pole to an industrial building.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 47 All Rights Reserved Example 4 This image shows data collected along a driveway next to a business. This shows a concrete culvert with a cable running through it.
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 48 All Rights Reserved Example 5 This image shows a gas line and communication cables (Fiber Optic) going across a driveway
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 49 All Rights Reserved Appendix E: Glossary of Terms  Dielectric: A value assigned to materials and is used to calculate the velocity of RADAR in that material. RADAR will travel at different speeds depending upon the material and/or soil condition. RADAR travels fastest in air (dielectric = 1) and slowest in water (dielectric = 81). Everything else falls somewhere in between. It is important to know the dielectric value of a material so that the depth of a target can be calculated. Since determining dielectric is a best guess estimate, the depth of a target will never be an exact measurement. As a safety feature, you will always give about a 1 foot (or about 1/3 meter) margin of error when estimating the depth of a target. Filter: A process to remove unwanted noise in the data so that targets can be seen more clearly. Filtering is a trial and error process, therefore trial runs are necessary using different filtering values to determine the best configuration for a  job site. There are two types of filtering: Background Removal: This filter will remove unwanted noise that looks like horizontal banding across your data. Using this process, this will remove data that is consistent throughout your data.       No Background Removal Background Removal
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 50 All Rights Reserved Stacking: This filter will remove unwanted noise that looks like fuzziness in your data. By selecting a value of 3, 5, 9, or 15, the process with take each scan and replace that scan with the average values of the surrounding scans. Be aware that too much stacking can filter out real targets. In this example, stacking of 3 is the best result. Targets at the top begin to disappear with higher scans to average.    No Stacking Stacking = 3 Stacking = 15 Stacking = 9 Stacking = 5
Quick Start Guide UtilityScan DF  Copyright © 2012 Geophysical Survey Systems, Inc. 51 All Rights Reserved Gain: Adding or subtracting Gain from data will amplify or lower the image of the RADAR signals. It is advised that you use the lowest gain that will show targets.  Gain too low Correct Gain Gain too high
    The following pages are additional documents included in the GSSI Manual CD that ships with each product.
FCC Notice (for U.S. Customers): This device complies with part 15, class F of the FCC Rules: Operation is subject to the following conditions: 1. This device many not cause harmful interference, and 2. This device must accept any interference received, Including interference that may cause undesired operation Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Operation of this device is restricted to law enforcement, fire and rescue officials, scientific research institutes, commercial mining companies, construction companies and private parties operating on behalf of these groups. Operation by any other party is a violation of 47 U.S.C. § 301 and could subject the operator to serious legal penalties. Coordination Requirements (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination. (b) The users of UWB imaging devices shall supply detailed operational areas to the FCC Office of Engineering and Technology who shall coordinate this information with the Federal Government through the National Telecommunications and Information Administration. The information provided by the UWB operator shall include the name, address and other pertinent contact information of the user, the desired geographical area of operation, and the FCC ID number and other nomenclature of the UWB device. This material shall be submitted to the following address:     Frequency Coordination Branch, OET    Federal Communications Commission    445 12th Street, SW    Washington, D.C. 20554    ATTN: UWB Coordination  (d) Users of authorized, coordinated UWB systems may transfer them to other qualified users and to different locations upon coordination of change of ownership or location to the FCC and coordination with existing authorized operations. (e) The NTIA/FCC coordination report shall include any needed constraints that apply to day-to-day operations. Such constraints could specify prohibited areas of operations or areas located near authorized radio stations for which additional coordination is required before operation of the UWB equipment. If additional local coordination is required, a local coordination contact will be provided. Notice: Use of this device as a wall imaging system is prohibited by FCC regulations.
For U.S. Customers Ground Penetrating Radar Coordination Notice And Equipment Registration  Note: This form is only for Domestic United States users. The Federal Communications Commission (FCC) requires that all users of GPR who purchased antennas after July 15th, 2002 register their equipment and areas of operation. It is required that you fill out this form and fax or mail to the FCC.  Failure to do this is a violation of Federal law.   1. Date:  2. Company name:   3. Address:   4. Contact Information [contact name and phone number]:   5.  Area Of Operation [state(s)]:          ---Continued on next page.
6.  Equipment Identification:  Brand Name: Geophysical Survey Systems, Inc. Antenna Model No. (center frequency):  List all antennas being registered. Model Frequency FCC ID (QF7 followed by Model #)                                      7.  Receipt Date Of Equipment:  Fax this form to the FCC at: 202-418-1944 Or  Mail to: Frequency Coordination Branch, OET Federal Communications Commission 445 12th Street, SW Washington, D.C. 20554  ATTN: UWB Coordination  Do not send this information to GSSI.
Canadian Requirements for RSS-220 Canadian Requirements of RSS-220 for Ground Antennas This Ground Penetrating Radar Device shall be operated only when in contact with or within 1 m of the ground. This Ground Penetrating Radar Device shall be operated only by law enforcement agencies, scientific research institutes, commercial mining companies, construction companies, and emergency rescue or firefighting organizations. Cet appareil de radar de sol (ou géoradar) ne doit être utilisé qu’en contact avec le sol ou à 1 m maximum au dessus du sol. Cet appareil de radar de sol ne doit être utilisé que par les forces de l’ordre, les instituts de recherche scientifiques, les sociétés minières, les sociétés de construction, et les organisations de secours d’urgence ou de combat du feu. Canadian Requirements of RSS-220 for Hand-held Antennas This In-wall Radar Imaging Device shall be operated where the device is directed at the wall and in contact with or within 20 cm of the wall surface. This In-wall Radar Imaging Device shall be operated only by law enforcement agencies, scientific research institutes, commercial mining companies, construction compa nies, and emergency rescue or firefighting organizations. Cet appareil de radar de structure (murs, poutres, dalles…) ne doit être utilisé qu’en contact avec la structure ou à 20 cm maximum décollé de cette structure. Cet appareil de radar de sol ne doit être utilisé que par les forces de l’ordre, les instituts de recherche scientifiques, les sociétés minières, les sociétés de construction, et les organisations de secours d’urgence ou de combat du feu. Canadian Requirements of RSS-220 for Search and Rescue Antennas This Through-wall Radar Imaging Device shall be operated only by law enforcement agencies or emergency rescue or firefighting organizations that are under a local, provincial or federal authority. The equipment is to be operated only in providing services and for necessary training operations. Cet appareil de radar au travers des murs ne doit être utilisé que par les forces de l’ordre ou les organisations de secours d’urgence ou de combat du feu qui sont sous une autorité locale, provinciale ou fédérale. Cet équipement ne doit être utilisé que dans le cadre de services et pour les opérations d’entrainement nécessaires.
 Geophysical Survey Systems, Inc. 12 Industrial Way Tel 603.893.1109 • Fax 603-889-3984 Salem, NH  03079-4843 www.geophysical.com • sales@geophysical.com Declaration of CE Conformance Geophysical Survey Systems, Inc. hereby confirms that the following named products have been tested and meet the requirements of the European standards as indicated:  Models: 3101A, 5106A, 5100B, 5101, 52600, 62000,MINISIR, MINIHR, LL3P, 41000SA, 42000S, 50400S, 50270S, D50300/800 Description: Ground Penetrating Radar Antennas European Standards:  ETSI EN 301 489-32 V1.1.1 (2005-09), ETSI EN 301 489-V1.6.1 (2005-09), ETSI EN 302 066-1 V1.1.1(2005-09), ETSI EN302 066-2 V1.1.1 (2005-09),  ETSI EN 302 066-1 V1.2.1(2008-02), ETSI EN302 066-2 V1.2.1 (2008-02), ECC/DEC/(06)08 Place and Date of Issue: Intertek – ETL SEMCO 07.02.07, 03.11.09, 10.13.09, 11.18.09         Compliance Worldwide 03.23.12 09.25.09 Model: EMP-400 Profiler Description: Electromagnetic Induction System European Standards: EN61326:1997 + A1:1998 + A2:2001 Place and Date of Issue: Intertek – ETL SEMCO 08.29.06 Model: FGMF20/3000 Description: Two channel Ground Penetrating Radar data acquisition system European Standards: EN61000-6-2: 2005, EN61000-6-4:2007 Place and Date of Issue: Intertek – ETL SEMCO 09.17.08 Model: FGDC-3000/2100, Structurescan EZ System, Structurescan MINI System Description: Ground Penetrating Radar Data Acquisition Systems European Standards: EN61000-6-2:2005, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 Place and Date of Issue: Compliance Worldwide 09.29.09, 11.25.09 Models: SIR-30, SIR-30e Description: Ground Penetrating Radar Data Acquisition System European Standards: EN61000-6-4: 2007 per EN 55011:2009 + A1:2010 Place and Date of Issue: Compliance Worldwide 07.10.12, 07.11.12     Chris Plumlee 11.07.12  Name of authorized person

Navigation menu