Geophysical Survey Systems MINISIR MINISIR User Manual Structure Scan III

Geophysical Survey Systems, Inc. MINISIR Structure Scan III

User Manual

StructureScan Mini Quick Start Guide A Fast Check List For Field Operation  Section 1: Getting Started ....................................................................................................................................... 1Section 2: Configuring the Structure Scan Mini ............................................................................................. 3Section 3: Collecting Data ....................................................................................................................................... 8Section 4: Data Playback and Review .............................................................................................................. 14Section 5: Reset To Factory Settings ................................................................................................................ 20Appendix A – Inventory Of Your System ........................................................................................................  21Appendix B – Battery/Charger Information .................................................................................................. 22Appendix C – Sample Data .................................................................................................................................. 23   Copyright © 2009 Geophysical Survey Systems, Inc.  MN70-583 Rev – All Rights Reserved
  Limited Warranty, Limitations Of Liability And Restrictions Geophysical Survey Systems, Inc. hereinafter referred to as GSSI, warrants that for a period of 24 months from the delivery date to the original purchaser this product will be free from defects in materials and workmanship. EXCEPT FOR THE FOREGOING LIMITED WARRANTY, GSSI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. GSSI's obligation is limited to repairing or replacing parts or equipment which are returned to GSSI, transportation and insurance pre-paid, without alteration or further damage, and which in GSSI's judgment, were defective or became defective during normal use. GSSI ASSUMES NO LIABILITY FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES CAUSED BY PROPER OR IMPROPER OPERATION OF ITS EQUIPMENT, WHETHER OR NOT DEFECTIVE. Before returning any equipment to GSSI, a Return Material Authorization (RMA) number must be obtained. Please call the GSSI Customer Service Manager who will assign an RMA number. Be sure to have the serial number of the unit available Regulatory Information Please see the GSSI Manual CD or our website, www.geophysical.com/regulatoryinformation.htm, for current information and FCC Registration Form, including: • FCC Notice for U.S. Customer • Canadian Requirements for RSS-220 • Declaration of CE Conformance
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  1Section 1: Getting Started 1 Power up the Structure Scan Mini. • Insert the battery into the slot of the Mini. Make certain the battery is “locked” in position. • Press the power button. A green light will illuminate on the power button. 2 After a few seconds, the system will boot up and the splash screen (Main Menu) is displayed. • The Green/Gray bar that is displayed on the lower left hand corner is a battery life indicator. This will display how much battery time is remaining. • The current time (as stored in the Mini) is displayed at the bottom of the screen. • How much storage you have left (the distance you have left to scan) is displayed on the lower right hand corner.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  23 To power off the Mini, simply press and hold the power button for approximately 2 seconds. Then you may remove the battery by pressing down on the tab of the battery and pulling down. 4 Note the buttons on the handle of the Mini. They will be referred as Left Arrow Í, Right Arrow Î, Up Arrow Ï, Down Arrow Ð, and Enter    buttons relative to the screen. Unless otherwise noted, this button, regardless of orientation, will return you to the previous screen or menu. 5 Depending upon the orientation of the screen on the Mini (Left or Right depending upon which hand you use), the Left, Right, Up, and Down buttons are switched. However, you will still be pressing Í, Î, Ï, and Ð buttons, regardless of the orientation of the screen. The “Enter” button (  ) will always be the button located in the center. • At any time unless otherwise noted, you may press the Arrow button closest to the rear of the Mini to return to the previous screen or menu. • The system comes with a GSSI strap to be attached to the back of the Mini. This strap should go around your wrist to prevent the Mini from being dropped.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  3Section 2: Configuring the Structure Scan Mini Before collecting any data, you may want to configure your Mini. System Menu Option 1 From the Main Menu, select System by pressing Ï.  2 Use Ï and Ð buttons to highlight the appropriate options under the System Menu. Date/Time: Configuring Date and Time 1 Highlight Date/Time and press Enter. 2 Highlight any of the options you wish to change and press Enter. The following options will appear at the bottom of the screen: • Change Value – Use Ï and Ð to change the value. • Set Value – Press the Enter button to accept your change. • Quit – Use Î to quit WITHOUT saving the changes. 3 Press Î to return to the previous menu.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  4Configuration: Configuring Orientation, Language, Units, Laser, and Sound 1 Highlight Configuration and press Enter.  2 Press Ï Ð to select the appropriate options: • Orientation – Press Enter to toggle between Right or Left. This will flip the screen to allow for either right or left handed operation. Note: Switching the orientation will automatically switch the buttons as well. • Language – Press Enter to select your language preference. • Units – Press Enter to toggle between English or Metric • Laser – Press Enter to toggle marking assist laser On or Off. • Sound – Press Enter to toggle between High, Medium, Low, or Off • Version(s) – Press Enter to display the version number of the software. 3 Press Î to return to the previous menu. Calibration: Auto Calibrations for Surface and Brightness 1 Highlight Calibration and press Enter. a) Hold the Mini upside down about 1 meter (3 ft) from any surface. b) Press the Enter button.  The Auto-Calibration will take several seconds. 2 Press Î to return to the previous menu.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  5Clear Storage: Deleting Saved Data A project is a folder which holds individual files. 1 Highlight Clear Storage and press Enter. 2 At the bottom of the screen, a new set of options is displayed. Deleting All Projects or Deleting Specific Projects All Projects: If you wish to delete ALL of your projects and all the files associated with each project: 1 Press Í when Clear All is displayed. 2 Press Ï to confirm, Ð to cancel the deletion. Specific Projects: If you wish to delete a specific project or specific files within a project: 1 Press Ï Ð to select the specific project. 2 Press Í to delete that entire project (and all the files associated with that project). 3 Press Ï to confirm, Ð to cancel. 4 At any time, you may press Î to quit.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  6Specific Files in a Specific Projects: Deleting specific files within a specific project: 1 Press Ï Ð to select a specific project.  2 Press Enter to select that project. 3 Press Ï Ð to select a specific file. 4 Press the Enter button to delete the selected file. 5 Press Ï to confirm, Ð to cancel. 6 At any time, you may press the Î to quit.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  7Scan Density: Selecting the Scan Density 1 Highlight Scan Density. 2 Press Enter to toggle between High and Normal. • High – The Mini will scan at 4 scans/cm (approximately 120 scans/ft). Use this is when you are looking for very small objects. • Normal – The Mini will scan at 2 scans/cm (approximately 60 scans/ft). Use this is when you are looking for normal size objects Backlight: Setting the Brightness of the Mini Backlight 1 Highlight Backlight. 2 Press Enter to toggle between 25%, 50%, 75%, or 100%. Save Prompt: Whenever Saving, Have the System Prompt You to Save or Save Automatically 1 Highlight Save Prompt. 2 Press Enter to toggle between On or Off. • On – The system will prompt you to save a file. • Off – The system will save the file automatically.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  8Section 3: Collecting Data After your configuration is complete, you are now ready to collect data. Collect Menu Option 1 From the Main Menu, select Collect by pressing Í.  2 Use Ï Ð buttons to highlight the appropriate options under the Collect Menu. Before you begin to collect data (Start Collect), you may want to configure the Mini for a particular scan/project. Project: Saving Files to a Specific Project 1 Highlight Project and press Enter. 2 Highlight a Project number and press Enter. All files that you save during collection will be saved under this project. (Note: you may want to take field notes to document what files went under which project). Depth: Selecting the Depth Where You are Scanning 1 Highlight Depth. 2 Press Enter to toggle between 8, 12, and 16 inches (20, 30, and 40 cm).
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  9Dielectric: Selecting the Approximate Dielectric of the Area You are Scanning 1 Highlight Dielectric and press Enter. Change the Dielectric value by: • Í to change the number after the decimal point. • Ï Ð to change the number before the decimal point. • Î to quit WITHOUT saving the new value. • Press Enter to set your new value. Having the correct value will improve your depth accuracy. A higher value is necessary for young concrete or concrete that is under water.   • Less than 2 months/outside in wet environment, use 9+ • Younger than 12 months/outside, use 7-8 • Older than 12 months/indoor/dry, use 5-6 For more detailed information on concrete dielectric values, refer to the GSSI Handbook for RADAR Inspection of Concrete that came with your system on the documentation CD.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  10Autotarget: Allowing the Mini to Automatically Pick Your Targets 1 Highlight AutoTarget. 2 Press Enter to toggle between On and Off. • On – The Mini will place dots on what it interprets as targets as you collect data, and when pulling the  Mini straight back. • Off – No dots and no interpretation will be done by the Mini. Display: While Collecting Data, Display Data Only or Data + O-Scope 1 Highlight Display. 2 Press Enter to toggle between B (data only) and A+B (data + o-scope).  Data Only display during collection  Data + O-Scope display during collection
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  11Color: Choosing the Colors You Want Displayed During Data Collection 1 Highlight Color. 2 Press Enter to toggle between five different color schemes to be displayed during collection. Collecting Data and Marking Your Targets 1 Highlight Start Collect and press Enter. The following screen is displayed. 2 Note the information at the top of the screen: • Depth – The depth you have chosen for this scan. • Dist. – The distance you have scanned. • Diel. – The dielectric you choose for this scan. • “File____###” – The filename of this scan if you choose to save this file. 3 Move your cart forward. Data only gets collected when you move the cart forward. 4 Once you start seeing hyperbolas on the screen, pull the system straight back along your survey line. You will see a vertical line (the backup cursor) scroll along your data. When that vertical line is right over the apex of the hyperbola, the center of the antenna is over that target.  Note: When you pull the Mini straight back, and if you configured AutoTarget On, the Mini will interpret targets by placing yellow dots on the targets.   Backup Cursor
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  12epth.  to Set Depth. The vertical scale will adjust and the dielectric will be  se the 5 The center of the antenna is directly under the Mini. After marking the location of the target on the ground using the laser (if configured On) at each side of your cart as a guide (or the groove on each side of the cart as a guide if the laser is configured Off). Push the cart straight forward or move the cart to do another line scan. No data will be collected until you have passed the spot where you started to reverse. 6 If you wish, you may calibrate depth (optional). Match the target location in the data to its location in your survey area. Drill down to that target and measure the depth. a) Press Enter “Depth Cursor” and backup the Mini to bring up the crosshairs and set them over the target in the data. b) Press Ï Ð to line up the horizontal line in the middle of first dominant color of that target. c) Press Enter to Set Depth. d) Press Ï Ð until the Depth in the upper left hand corner matches the measured de) Press Íupdated. Please note that this is only an approximation of the true depth becaudielectric value or constant  can change with depth and across the site. f) Press Î (Back) to continue scanning.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  137 Other Options • Press and HOLD Ï (New File) to save your current scan. If you have configured Save Prompt On, you will be prompted to confirm the save. Press Ï to Save, Ð to not save the data. If you have configured Save Prompt Off, it will save automatically. • Press Í to place a user mark in your data. • Press Î to exit. If you have configured Save Prompt On, you will be prompted to confirm the save. Press Ï to save, Ð to not save the data. If you have configured Save Prompt Off, it will save automatically.  Helpful Hint: Make a sketch map of your survey area with immovable objects as reference points. Sketch in your survey files, note the start and stop points, direction of travel, and file name on the map. This will make it much easier to relocate your targets after the survey. Helpful Hint: The top of a target is generally the middle of the first positive peak for metal targets (rebar, tensioned cable, wires in PVC, conduit). If you are working in a grayscale color table, the positives are white. If the utility is air or gas filled (empty PVC, voids) the top of the target is the middle of the first negative peak (black).  Please refer to Appendix C for examples of the different types of data.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  14Section 4: Data Playback and Review The Playback menu provides tools to help you interpret your data. None of these functions are required to get interpretable data. They are simply meant to help you in the interpretation of the data. These functions do not permanently change your data or affect your saved data in any way. More intensive processing can be done in the RADAN processing program (sold separately).  Playback Menu Option 1 From the Main Menu, select Playback by pressing Î.  2 Use Ï Ð to highlight the appropriate options under the Playback Menu. Before you begin to playback data (Playback), you may want to configure the Mini to give you some helpful tools in the interpretation of the data. Project: Selecting a Specific Project to Select a Specific File to Playback 1 Highlight Project. 2 Highlight and press Enter to select the project where the file you want to play back is located. 3 Highlight and press Enter to select the specific file you want to play back.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  15AutoDepth: Automatically Adjusting Depth Scale 1 Highlight AutoDepth. 2 Press Enter to toggle between Auto and Orig. • Auto – The Mini will estimate the depth of targets and automatically adjust the Depth Scale. • Orig – The Mini will use the original value set during collection. Autotarget:  Allowing the Mini to Automatically Pick Your Targets 1 Highlight AutoTarget. 2 Press Enter to toggle between On and Off. • On – The Mini will place dots on what it interprets as targets. • Off – No dots and no interpretation will be done by the Mini. Note: AutoTarget is for information purposes only and you should carefully examine your data to ensure that the Mini has correctly located objects.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  16Display: While Viewing Data, Display Data Only or Data + O-Scope 1 Highlight Display. 2 Press Enter to toggle between B (data only) and A+B (data + o-scope).  Data Only display during collection  Data + O-Scope display during collection             Color: Choosing the Colors to Display During Data Collection 1 Highlight Color. 2 Press Enter to toggle between five different color schemes to be displayed during collection.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  17Playing Back the Selected File 1 Highlight Playback. 2 Press Enter to play back the selected file. Note at the top of the screen the following information: • Depth • Distance • Dielectric • File name While in Playback, you will have an option to toggle between four different modes by simply pressing the Enter button. The mode you are in will be displayed at the bottom of the screen.  • Scroll Mode – Allows you to scroll your data left and right • Distance Cursor Mode – Allows you to move a vertical line left and right on your data • Depth Cursor Mode – Allows you to move a horizontal line up and down on your data.  • Set Depth Mode – Allows you to set a known depth to your targets. Data with AutoTarget OFF Data with AutoTarget ON
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  18Scroll Mode • Í Î – Scroll through your data. • Ï – Run Stop, while your data is scrolling, press Up Arrow to stop and start the scrolling. • Ð – Exit back to the Playback menu. If you added or deleted any targets, the system will prompt you to save your targets. Press Ï for Yes, Ð for No. • Enter – Switch to Distance Cursor Mode. Distance Cursor Mode • Í Î – Move the vertical line left and right. • Ï – Place a user mark at the location of the vertical line. • Ð – Return to Scroll Mode. • Enter – Switch to Depth Cursor Mode.   Vertical Line
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  19croll Mode Depth Cursor Mode • Ï Ð – Move the horizontal line up and down. • Í – Toggles between placing and deleting a dot to mark a target where the  cross hairs are. • Î – Return to Distance Cursor Mode. • Enter – Switch to Set Depth Mode. Set Depth Mode • Ï Ð – Entering a known depth for the target in the crosshairs. The upper left hand corner displays the depth • Í – Once the correct depth is displayed, set the depth. Note: If the depth of a target changes, this will automatically change the dielectric. • Î – Return to Depth Cursor Mode Horizontal Line• Enter – Switch to S
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  20Section 5: Reset to Factory Settings This will reset the Mini to the factory settings. This will NOT delete the data you have saved.  Simply press the Down Arrow from the Main Menu. • Ï to Confirm • Ð to Cancel
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  21Appendix A – Inventory of Your System 1 StructureScan Mini  1 SD card (already inserted into the back of the Mini) 1 Battery Charger (2 Slots) 1 Battery Charger Adapter 3 International Plugs for the Battery Charger Adapter 1 Quick Start Guide (This Manual) 1 USB Cable 2 Batteries 1 GSSI Strap 1 Documentation CD 1 Case Note: If you wish to transfer any saved data to your PC, simply remove the SD card and transfer the data to your PC.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  22Appendix B – Battery/Charger Information Your system comes with a two-slotted battery charger and adapter. It also comes with three international interchangeable plugs. • To charge your batteries, simply attach the adapter to the charger and plug in the adapter. Insert one or both batteries. The batteries will charge one at a time. The bars located at the top of the batteries will indicate how much charge is left in the battery. • At times, you may wish to re-calibrate a battery. Simply insert a battery into the slot on the left and press the RECAL button • LED Lights – As the batteries are charging, the LED lights for each slot will do different things. • No Lights – No Batteries • Green Flash – Fast Charging • Green Solid – Fully Charged • Yellow Flash – Recalibrating • Yellow/Green – Recalibrated • Yellow Solid – Standby • Red Flash – Error • If the charger remains plugged in and there are NO batteries in the charger, the charger will eventually begin to “beep.” Since this can be annoying, it is recommend that you unplug the charger when not in use.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  23Appendix C – Sample Data These examples are presented for informational use only. Conditions may be different at your site that may cause the images to look different from the data shown here. Example 1 – Concrete Block Data    Filled cell with rebar Voids (2) within the blocks User Marks entered during collection to identify the ends of each block (black lines)
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  24Example 2 – Rebar Data This is an example of rebar. Note the distance between the peaks here (as well as at the location if you marked the area) is approximately 8 inches. Also note the approximate depth, the brightness of the hyperbolas, and they tend to be at a constant depth over the short term.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  25Example 3 – Mesh Data This is an example of mesh. Note the distance between the peaks here (as well as at the location if you marked the area) is approximately 6 inches. Also note the approximate depth, the brightness of the hyperbolas, and mesh may be more uneven than rebar.
Quick Start Guide  StructureScan Mini  Geophysical Survey Systems, Inc.  26Example 4 – PVC This is an example of two PVC pipes. Note they tend to be dimmer than rebar.