Getac Technology EMPT116F Digitizer module User Manual OEM PRODUCT SPECIFICATION
Getac Technology Corporation Digitizer module OEM PRODUCT SPECIFICATION
Contents
- 1. User Manual Host
- 2. User Manual Module
User Manual Module
EMPEN T116 Sensor SPECIFICATION Product Name:TF1-DIGITIZER;ASIC,11.6”,F110G4,EMP Getac P/N: 412888700007 EMPEN P/N : 20160002 Firmware Version : 18 Revision History Revision Date Description Author /Revised by 01 2016/11/29 Initial Jesse 1. Product Specifications 1.1 General Specifications Technology Battery free Electro-magnetic Interface USB VID & PID VID:0x0458, PID:0x501D Active Area 258.13×146mm Resolution 0.01mm / 2560 LPI (see Note 5) Coordinate Accuracy ±0.4mm (see Note 1, 2, 3 and 5) Coordinate Jitters 1-point max (see Note 1 and 5) Detectable Pen tilt Up to 50° from vertical (see Note 5) Detectable Height 4 to 14mm above the Sensor Film (see Note 1 and 5) Position Report Rate 133 PPS ( Pen hover at sensor center ) Pressure Resolution 1024 levels (see Note 4 and 5) EM module Thickness 3.0 mm max Note 1: The EM Sensor Board and Stylus at ordinary temperature. Note 2: The pen held vertically at 0mm high from sensor film. Note 3: See Picture1, the accuracy guaranteed region is 15mm or more inside region from the active area edge. Note 4: Pressure range is 20g≦200 levels and 650g≦1023 levels Note 5: This function must be used with Getac TF1-DIGITIZER PEN unit Picture1 1.2 Dimensional Outline of PCBA and Sensor Film 1.3 Electrical Specifications 1.3.1 Circuit Diagram TLSC3590ET88 Controller Board Signal Assignment Sensor Film Pin Name Function NC Not Connect USB- USB- Signal USB+ USB+ Signal NC Not Connect NC Not Connect NC Not Connect VCC +5V Power Supply GND Ground 1.3.2 Test Conditions Ambient Temperature : 25+/- 5 ℃ Ambient Humidity : 65 +/- 16% ( RH) Supply Voltage : VDD 5V Item Min. Typ. Max. Unit. 4.75 5.0 5.25 75 80 98 mA Current Consumption Pen@10cm 85 90 100 mA Current Consumption Standby mode 84 110 124 mA Supply Voltage Current Consumption Pen in touch Low Scan mode 16 (400mSec) 35 125 (130mSec) mA Remark Keep standby mode 40 min will entry low scan mode 2. Reliability Test Item Humidity Test SPEC Testing method 30℃/95%~61℃/95%, 1. All functions must be 12 hours for 30℃/95%, MIL-STD-810G- 507.5 normally 12 hours for 61℃/95%, Humidity Procedure – II 2. No oxidation on one cycle is 24 hours , Aggravated test time is 10days High Temperature Test (Operating) High Temperature Test (Non-Operating) Criteria 61℃ 96h 3. No visual abnormal. MIL-STD-810G-501.5 4. There shall not be any Procedure II Operation cosmetic damage 5. T/S cannot allow the 12 hours for 31℃, abnormal status like one cycle is 24 hours, screws. 33℃~71℃ ,10days 12 hours for 71℃ Number of test samples MIL-STD-810G-501.5 Procedure I peel off, bubble . test time is 10days Low Temperature Test (Operating) Low Temperature Test (Non-Operating) Drop Test Temperature Shock Test -21℃ 96h -40℃ 96h MIL-STD-810G-502.5 Procedure II MIL-STD-810G-502.5 Procedure I 1h, 3cycle ,total:6h 120cm Wood floors -41℃~71℃ duration MIL-STD-810G-503.5 Procedure-I-C Multi-cycle shock.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : rhett 陳文政 Create Date : 2017:08:09 13:22:14+08:00 Modify Date : 2017:08:15 17:01:33+08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2017:08:15 17:01:33+08:00 Creator Tool : Microsoft® Word 2010 Format : application/pdf Title : OEM PRODUCT SPECIFICATION Creator : rhett 陳文政 Document ID : uuid:a1c0517d-82f9-498f-b59a-03a61a00ab8d Instance ID : uuid:b2af937d-f551-4411-83e2-e3e9e8b78f72 Producer : Microsoft® Word 2010 Page Count : 6EXIF Metadata provided by EXIF.tools