User ManualSystem OverviewTM-915 is designed of 902MHz to 928MHz reader module for UHF RFID, usuallyapplied to PC . Our advance technology delivers small, reliable, easy to design andcost-effective EPC C1G2 UHF reader module solution. TM-915 also compatible withISO-18000-6C. Its simplified Uart interface, low power consumption and highperformance, make it easily to integrate any device with UHF technology.PC system: Windows XP/Vista/7/8 (32 & 64-bit)USB to UART driverAbove Net_Framework_4.0FAVEPC Reader Utility software1. First install PL2303_Prolific_DriverInstaller_v1_12_0 file. The file download Webside refer to the belowhttp://www.prolific.com.tw/UserFiles/files/PL2303_Prolific_DriverInstaller_v1_14_0.zip2. Install process:Step 1: Next
Step 2: Finish and PC restart3. Install the above Net_Framework_4.0 file,The file download Web side refer tothe belowhttps://www.microsoft.com/zh-tw/download/details.aspx?id=177184. USB Reader plug to PC USB port and Run Reader Utility software,refer to thebelow:Check the box【Enter Reader】and Enter the operating window.
Operating command refers to the below:1.1 Q command:Read EPC data from single TAG. Check the box【EPC(Q)】. It can read TAG EPCdata.If it need continue to read single TAG. First check the box【Cont.】and checkthe box【EPC(Q)】again.Check the box【STOP】. It stops to read the TAG EPC.1.2 U commandRead many EPC data from multi-TAG. First check the box【Multi】and checkthe box【EPC(U)】If it need continue to read Multi-TG. First check the box【Cont.】and【Multi】,check the box【EPC(U)】.
check the box【STOP】. It stops to read multi TAG.1.3 【TID】buttonReal command is <LF>R2,0,4<CR>. It can see the real command in Infowindows at lower right corner. The【TID】button is used to read single TAG.If it need continue to read single TAG, check the box【Cont.】and checkthebox【TID】.check the box【STOP】. It stops to read multi TAG.1.4 R command (Read operation):1.4.1 First select the 【Memory Bank】,Drop-down menu:【00:RESERVED】【01:EPC】【02:TID】【03:USER】【00:RESERVED KillPwd】【00:RESERVEDAccessPwd】1.4.2 Enter number in【Address】and【Length(word)】1.4.3 Check the Box【Read】to get the data.1.5 W command (Write operation):1.5.1 First select the【Memory Bank】1.5.2 Enter number in【Address】and 【Length(word)】1.5.3 Enter the HEX data to the write windows1.5.4 Check the box【Write】. The result show in Info windows at lower rightcorner. If it is right, it show the <LF>W<OK><CR><LF>.1.5.5 Check the box【Read】. It can get the data if it writes data to the TAG.
1.6 Lock operation1.6.1 Check the box from Kill pwd options. It can select four items.1.6.1.1 【skip】:not change1.6.1.2 【Readable and writable】:TAG can be Readable and writable1.6.1.3 【Permanently Readable and writable】:TAG can be PermanentlyReadable and writable. It can’t be change the status after thesetting.1.6.1.4 【Need password to readable and writable】:TAG need passwordto readable and writable1.6.1.5 【Need password to permanently readable and writable】:TAGneed password to permanently readable and writable. It can’t bechange the status after the setting.1.6.2 Check the box from Access pwd options. It can select four items.1.6.2.1 【skip】:not change1.6.2.2 【Readable and writable】:TAG can be Readable and writable1.6.2.3 【Permanently Readable and writable】:TAG can be PermanentlyReadable and writable. It can’t be change the status after thesetting.1.6.2.4 【Need password to readable and writable】:TAG need passwordto readable and writable1.6.2.5 【Need password to permanently readable and writable】:TAGneed password to permanently readable and writable. It can’t bechange the status after the setting.1.6.3 Check the box from EPC bank options. It can select four items.
*EPC data always can be read.1.6.3.1 【skip】:not change1.6.3.2 【Writable】:TAG can be writable1.6.3.3 【Permanently writable】:TAG can be permanently writable. Itcan’t be change the status after the setting.1.6.3.4 【Need password to writable】:TAG need password to writable1.6.3.5 【Need password to permanently writable】:TAG need passwordto permanently writable. It can’t be change the status after thesetting.1.6.4 Check the box from TID bank options. It can select four items.*TID data always can be read. Normal TAG TID can’t be written. It need refer to the TAG ICspecification.1.6.4.1 【skip】:not change1.6.4.2 【Writable】:TAG can be writable1.6.4.3 【Permanently writable】:TAG can be permanently writable. Itcan’t be change the status after the setting.1.6.4.4 【Need password to writable】:TAG need password to writable1.6.4.5 【Need password to permanently writable】:TAG need passwordto permanently writable. It can’t be change the status after thesetting.1.6.5 Check the box from USER bank options. It can select four items.*USER bank data always can be read.1.6.5.1 【skip】:not change1.6.5.2 【Writable】:TAG can be writable1.6.5.3 【Permanently writable】:TAG can be permanently writable. Itcan’t be change the status after the setting.
1.6.5.4 【Need password to writable】:TAG need password to writable1.6.5.5 【Need password to permanently writable】:TAG need passwordto permanently writable. It can’t be change the status after thesetting1.6.6 For example. We will select (Need password to readable and writable)option at all item. Check the box【Lock】. The result show in Infowindows at lower right corner. If it is right, it show the<LF>L<OK><CR><LF>.1.7 Kill Password Setting1.7.1 At【Memory Bank】of Read/Write operation item,Drop-down menuselect【00:RESERVED KillPwd】item.1.7.2 Check the box【Read】,Default value is 00000001.7.3 For example. Write password is 12345678,check the Box【Write】. Theresult show in Info windows at lower right corner. If it is right, it showthe <LF>W<OK><CR><LF>1.8 Access Password Setting1.8.1 At【Memory Bank】of Read/Write operation item,Drop-down menuselect【00:RESERVED AccessPwd】1.8.2 Check the box【Read】,Default value is 00000001.8.3 For example. Write password is 12345678,check the Box【Write】. The
result show in Info windows at lower right corner. If it is right, it showthe <LF>W<OK><CR><LF>1.9 P command:1.9.1 The all operations are be locked the password. So we need use Pcommand before the other command operates.1.9.2 Write the password (12345678) at Access Password item1.9.3 Check the box【Set access to pre-command】1.9.4 We can read TAG to get the EPC data.1.9.5 We can see the information in Info windows at lower right corner. TheR command. It isn’t need the password to read EPC data. Because theEPC data always can be read. But we need write the ECP data. If itdoesn’t run the P command, it will resend the error code (4). It meansthe memory is locked. So we run the P command first andimmediately run W command. It can write data to EPC bank memory.1.10 Kill command1.10.1 Enter kill password 12345678 at Kill pwd item1.10.2 Check the box【Kill】. The TAG will be kill and can’t be used again.1.11 T command ---Select TAG operation
1.11.1 It need select one TAG operation at Multi-TAG. It need use the TCommand to select specific TAG.1.11.2 Check the box【Multi】first and check the box【EPC(U)】1.11.3 It show the Multi-TAG data at Top right of the window1.11.4 At Pre-setting item1.11.4.1 Check the box【Set select to pre-command】1.11.4.2 Select【01:EPC】at Memory Bank1.11.4.3 Enter number(70) at Address(bit) *Warning : Address unit isbit, the value is HEX. So HEX(7*16)=HEX(112)=70 hex1.11.4.4 Enter number (10) at Length(bit) * Warning : Length unit isbit, the value is HEX. So HEX(1*16)=HEX(16)=10 hex1.11.4.5 Enter last four numbers of EPC at Data item. For example. Thenumber is 8DE0 or 8DDF.1.11.5 At Read/Write item1.11.5.1 Select【01:EPC】at Memory Bank1.11.5.2 Check the box【Read】. We can get the EPC data by selected TAG1.11.6 It shows the command process in Info windows at lower right corner.
Federal Communication Commission Interference StatementThis equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to Part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residentialinstallation. This equipment generates, uses, and can radiate radio frequency energyand, if not installed and used in accordance with the instructions, may cause harmfulinterference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does causeharmful interference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:•Reorient or relocate the receiving antenna.•Increase the separation between the equipment and receiver.•Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.•Consult the dealer or an experienced radio/TV technician for help.FCC Caution:This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that maycause undesired operation.Statement:Changes or modifications not expressly approved by the party responsible forcompliance could void the user’s authority to operate the equipment.FCC Radiation Exposure Statement:This equipment complies with FCC radiation exposure limits set forth for anuncontrolled environment. This equipment should be installed and operated withminimum distance 20cm between the radiator & your body.