Gilbarco MRIR3 Radio Frequency Identification Device User Manual

Gilbarco Inc. Radio Frequency Identification Device

Users Manual

Download: Gilbarco MRIR3 Radio Frequency Identification Device User Manual
Mirror Download [FCC.gov]Gilbarco MRIR3 Radio Frequency Identification Device User Manual
Document ID115062
Application IDE+iOLCgihazLNjh0W09tkw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.77kB (309638 bits)
Date Submitted2000-08-30 00:00:00
Date Available2001-04-05 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat Distiller 3.01 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleUntitled Document
Document CreatorFrameMaker 5.5.6p145

MDE-3801A
TRIND™ MULTI 1
Transmitter/Receiver in Dispenser
Retrofit Kits C00012-002-XX
Installation
Introduction
Purpose of this Manual
This manual provides instruction for installing TRIND™ Multi 1 system for use in Marconi
products.
Important Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy, and if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense. Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate this equipment.
IN
Required Reading
If installing the equipment TRIND Multi 1 on gasoline dispensing equipment, the installer
must read, understand, and follow:
• this manual
• NFPA 30A, The Automotive and Marine Service Station Code
• NFPA 70, The National Electric Code
• applicable federal, state and local codes and regulations
Failure to do so may adversely effect the safe use and operation of the equipment.
Note: This kit must be installed by a Marconi ASC (Authorized Service Contractor) to insure
warranty.
Required Tools
The following equipment may be needed to install all TRIND™ Multi 1 kits:
• Allen wrench set, American standard
• clean cloth or rag
• chip extraction tool, e.g., IC extraction, Digikey Part No. K158-ND or equivalent
• isopropyl alcohol (part# END-1082)
• needle nose pliers
• nut driver, 1/4'', 3/8''
• pocket knife
• Q12534 CRIND diagnostic card
• ratchet set, standard
• screwdrivers, flat and Phillips head
• static guard wrist strap
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Page 1
Parts List
Parts List
C00012-002 Kit
TRIND Multi 1 kits may be installed on a variety of Host Electronics (HE) systems. All kits
contain the parts detailed in table below. However, depending upon type of HE and equipment
receiving installation, additional parts or quantities of listed parts may be added to kits as
installation specific order entry items.
Description
Part Number
cable group (see table “Q13781-01 Cable
Group” on page 2)
Q13781-01
card cage assembly
T20538-G2
antenna/light assembly .
T20582-G1 (see note 1)
T20609-G1 (see note 2)
M01296A001 (see note 3)
jump jack
Q11011-01
label plate, FCC
N23936-01
manual, installation instructions
MDE-3801
Quantity
(see note 4)
10
IN
Notes:
1.
For wide frame The Advantage Pumps and Dispensers only. Assembly includes
T20545-G2 Light Board and R20718-G1 Antenna Cable
2.
For narrow frame The Advantage Pumps and Dispensers only. Assembly includes
T20545-G2 Light Board and R20718-G1 Antenna Cable
3.
For Marconi Encore Series units only. Assembly includes M001058 Antenna
Assembly and M001055 Light Board.
4.
Quantities determined at order entry.
Q13781-01 Cable Group
Cable group Q13781-01 for all kits contains the following cables:
Cables
Part Number
Quantity per kit
Gateway to CRIND logic
R20437-G01
AC power
R20580-G2
Light/Multi-protocol Reader
R20665-GX
(see note 5)
(see note 6)
Gateway to Light/MPR/Power Boards
R20724-G1
Notes:
Page 2
5.
Cable lengths (-GX) determined at order entry.
6.
Quantity determined at order entry.
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Safety Information
Safety Information
Alert Symbol and Signal Words
Alert Symbol:
This is a standard ANSI* approved alert symbol. When you see this symbol, be alert to the
potential for a personal injury.
* Reference American National Standard Bulletins ANSI Z535.
Signal Words:
These signal words alert you to important safety hazards.
WARNING
The hazard or unsafe
practice may result in
severe injury or death.
CAUTION
The hazard or unsafe
practice could result in
minor injury.
DANGER
The hazard or unsafe
practice will result in
severe injury or death.
IN
Safety Symbols:
The following safety symbols are used throughout this manual to alert you to personal safety
hazards and precautions.
Explosive
Flammable
Electrical hazard
Use safety barricades
No people in area
No vehicles in area
OFF
Use emergency power disconnect
No open flames
No smoking
No power tools
Wear eye protection
Read all related manuals
Clean up spills
Turn power off
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Page 3
Safety Information
Use Electrostatic Discharge Precautions
Place yourself at a neutral static-free potential by doing the following:
1 Touch an unpainted metal surface.
2 Use a wrist strap connected to a grounded metal frame or chassis.
OFF
Note: Failure to use electrostatic discharge precautions may damage electronic components
and void warranty.
Make sure all power has been removed from unit and CRIND.
Follow OSHA Lock-Out and Tag-Out Requirements
OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/Tag-Out)
covers ways to avoid personal injury if power is turned on or fuel pressure is applied
unexpectedly while servicing equipment. The rule requires that equipment power and fuel
under pressure be turned off and the device (breaker, valve, etc.) locked or labeled with a
warning tag.
Read OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/
Tag-Out). Station employees and service contractors need to understand and comply with this
program completely to ensure safety while the equipment is down.
IN
Tag-Out and Lock-Out Procedure
Use plastic warning tags with signature/date blanks for Tag-Out. Sign and date them at shut
down. Attach tags with plastic connectors.
Use metal screw-down lock clamps or plastic single or multi-pole devices for Lock-Out of
breakers and switches. Always use a lock-out device whenever possible.
When working on electronics and electrical connections:
• Turn off unit power.
• Install lock-out device and tag on breaker(s).
Page 4
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Installation
Installation
Installing Cables
Note: Typical installation only (The Advantage Series).
Position kit cables according to the following steps:
1 Carefully pry out printer cable retainer from underside of printer shelf.
2 Disconnect printer cable and pull cable out of 2 3/4" round hole from bottom.
2 3/4” printer
cable hole
and cable
retainer
IN
3 Feed three-prong end of power cable R20580-G2, J250 end of R20437-G01 ribbon cable and
multiple connector ends of cables R20665-G1 and R20665-G2 up through hole and lay cable
ends toward A side.
R20580-G2
R20665-G1 and
R20665-G2 cables
R20437-G01
ribbon cable
4 Reinstall printer cable and retainer disconnected and removed in step 2.
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Page 5
Installation
T20538-G2 Card Cage
Connection points on T20538-G2 card cage.
Note: For more cable connection detail see “Cable Block Diagram (Typical)” on page 12.
Rear side of card
cage shown
J8 on DCB for
P8 on
R20665-G2 for
B side
Connect
R20580-G2
power cable
J7 on DCB for
P7 on
R02665-G1 for
A side
RS232 Port
IN
1 Connect three prong female end of power cable R20580-G2 to card cage at location shown.
2 Connect P7 on R20665-G1 to J7 and P8 on R20665-G2 to J8 on DCB at location shown.
3 Connect J186 on R20724-G1 cable to P186 on Gateway Board on top of card cage.
Page 6
Gateway
board on
top of
card
cage
For J186 on
R20724-G1
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Installation
Address Gateway Board Before Installing Card Cage
Address on HE must and Gateway Board must be set to match.
MOC and Generic CRIND Addresses.
Address On CRIND Logic Board T17764-XX
JP8
JP7
JP6
JP5
JP4
= Address on Gateway Board T20128 ‘A’ Side
JP6
JP7
JP8
JP9
JP10
= Address on Gateway Board T20128 ‘B’ Side
JP14 JP15 JP16 JP17 JP18
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
IN
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
OUT
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
10
IN
11
12
13
Jump jack locations on Gateway Board
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
IN
OUT
OUT
IN
OUT
OUT
IN
OUT
IN
OUT
IN
IN
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
IN
OUT
IN
IN
OUT
14
OUT
IN
IN
IN
OUT
15
IN
IN
IN
IN
OUT
16
OUT
OUT
OUT
OUT
IN
17
IN
OUT
OUT
OUT
IN
18
OUT
IN
OUT
OUT
IN
19
IN
IN
OUT
OUT
IN
20
OUT
OUT
IN
OUT
IN
21
IN
OUT
IN
OUT
IN
22
OUT
IN
IN
OUT
IN
23
IN
IN
IN
OUT
IN
24
OUT
OUT
OUT
IN
IN
25
IN
OUT
OUT
IN
IN
26
OUT
IN
OUT
IN
IN
27
IN
IN
OUT
IN
IN
28
OUT
OUT
IN
IN
IN
29
IN
OUT
IN
IN
IN
30
OUT
IN
IN
IN
IN
31
IN
IN
IN
IN
IN
32
OUT
OUT
OUT
OUT
OUT
Page 7
Installation
Install card cage assembly (typical).
Note: Typical installation (The Advantage Series Dispensers) procedure showing mounting
and securing points on card cage.
Tab on
card cage
clinch nut
card cage front facing B side
1 Locate tab at left front top of card cage.
IN
2 From B side, turn card cage sideways to unit, feed top and rear of card cage up and into shelf.
Note: Front of card cage will face B side.
3 Position card cage so that tab fits over latch cutout for main door latch, securing card cage to
shelf divider.
• If two screws on card cage pass through shelf secure from underside of shelf with two nuts
provided in kit.
• If screws were removed, secure card cage from underside of shelf by installing one screw
removed in section “Connection points on T20538-G2 card cage.” on page 6 up through
hole in shelf to clinch nut on card cage (see illustration above). Dispose of second screw
and two nuts.
Page 8
Tab locks into shelf divided at latch cut-out
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Installation
Connecting Remaining Cables
Note: Typical for The Advantage Series Dispensers. Connection points and cables are
universal.
1 From A side, pass J250 end of cable R20437-G01, J176 and JA ends of cable R20665-G1 and
J177 and PA ends of cable R20665-G2 through card cage to B side.
P186
P250 on
Gateway Board
pass cables
through cage
P176
P177
IN
JA and PA connectors on R20724-G1
2 From B side, connect J176 on cable R20665-G1 to P176 on Power Supply PCB.
Note: Detailed information provided on “Cable Block Diagram (Typical)” on page 12.
3 Connect J177 on cable R20665-G2 to P177.
4 Connect JA on R20665-G1 to PA on R20724-G1 cable.
5 Connect PA on R20665-G2 cable to JA on R20724-G1 cable.
6 Connect J250 on ribbon cable R20437-G01 to P250 on Gateway board on top of card cage.
From A side of unit make the following connections:
On ribbon cable R20437-G01, connect J258A/B to P258 on HE (Host Electronics) as specified
in HE documentation.
Connect R20580-G2 power cable according to the following:
Note: Connections are unit specific. Use appropriate connectors to intercept power by
installing R20590-G1 inline.
For units with:
Do the following:
System cable W02468
Install inline using 15 pin P601 and J601 connectors
System cable T19612
Install inline using 3 pin connectors J601/J708 and P601/P708
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Page 9
Card Cage Set-Up
Card Cage Set-Up
Addressing
Each operating unit (e.g., dispenser) on the HE controller must be addressed differently; no
two operating units may have the same address. Address is at discretion of the installer. Follow
these steps:
1 Locate dip switches on power supply board (PCB) T20314-G1 in card cage.
2 Using switches 2, 3, 4 and 5 address each operating unit according to the following table:
Note: Switch one in down position is standalone mode selected, used for service only.
Switch Numbers = Value
1 = Standalone Mode
2=1
3=2
4=4
5=8
IN
Dip switch down
Dip switch up
Page 10
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Card Cage Set-Up
Testing TRIND™ Multi 1
1 Restore power to HE unit.
2 Present test tag at antenna from a distance of 6’’ or less. Light board should light and flash
sequentially.
Note: If light does not function properly, for multi-antenna HE units check to see if opposite
side of unit was activated, indicating a crossed cable.
Completing Installation
1 Replace, close and/or secure all HE unit covers and/or doors.
2 Affix FCC label plate under existing FCC label.
3 Restore power to unit.
IN
MDE-3801A TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 07/00
Page 11
Card Cage Set-Up
Cable Block Diagram (Typical)
IN
FILTER
PRELIMINARY
© 2000 Marconi Commerce Systems Inc.
7300 West Friendly Avenue • Post Office Box 22087
Greensboro, North Carolina 27420
Phone (336) 547-5000 • http://www.marconicommerce.com • Printed in the U.S.A.
MDE-3801A • 07/00

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 12
Page Mode                       : UseOutlines
Create Date                     : 1910:00:72 41:61:64
Producer                        : Acrobat Distiller 3.01 for Windows
Title                           : Untitled Document
Creator                         : FrameMaker 5.5.6p145
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N6SMRIR3