Gilbarco TCR Card Reader Transmitter User Manual MDE 4770
Gilbarco Inc. Card Reader Transmitter MDE 4770
Gilbarco >
user manual
MDE-4770 Tribrid Card Reader Installation Manual June 2008 Introduction Purpose im 06 in /0 ar 4/ 08 This manual provides installation instructions for installing the M07999B001 Tribrid Card Reader (TCR). The TCR is used in Encore® S EMV units only. IMPORTANT INFORMATION re This equipment has been tested and found to comply with the limits pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment. The long term characteristics or the possible physiological effects of radio frequency electromagnetic fields have not been investigated by Underwriters’ Laboratories, Inc. (UL®). Table of Contents Topic Page Introduction Important Safety Information Installation of the TCR • Installing the M07999B001 TCR in an Encore S EMV Unit (without Contactless Card Reader Option) • Installing the M07999B001 TCR in an Encore S EMV Unit (with Contactless Card Reader Option) 12 Required Reading Before installing the Card Reader, the installer must read, understand, and follow: • This manual • NFPA 30A, The Automotive and Marine Service Station Code • NFPA 70, The National Electric Code • Applicable federal, state, and local codes and regulations Failure to do so may adversely affect the safe use and operation of the equipment. Note: This installation must be performed by a Gilbarco® Authorized Service Contractor (ASC) to ensure warranty. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 1 Introduction Required Tools Parts Lists lim in ry The following tools are required to install the TCR: • Isopropyl alcohol (END-1082) • Nut drivers, 1/4-inch, 8 mm, 3/8-inch, 9/32-inch socket with long extension • Putty knife • Gilbarco Diagnostic card • CSC test card • Ratchet set, standard • Screwdrivers, flat blade and cross tip • Static guard wrist strap The following table provides the parts included in the TCR Kit. Description Part Number Quantity Reader, Secure Tribrid M07999B001 Cable, TCR/SP Interface M07702A006 Cable, Encrypted Card M07709A001 Nut, Metric, Flange M00414B005 Bracket, Card Reader M07574B001 Gasket, Card Reader M00682B001 Screw Sel TP Hex HD 6-20X Q11677-26 Assembly, Contactless Antenna M08285A001 Cable, Antenna Encrypted M07703A001 10 Card, Card Reader Cleaning Q11482 re Item Related Documents Page 2 Document Number Title GOLD Library MDE-2562 CRIND Service Manual CRIND and TRIND® MDE-3804 Encore and Eclipse Series Start-Up/Service Manual Encore and Eclipse® MDE-3893 Encore/Eclipse Owners Manual Encore and Eclipse MDE-4516 Encore S Series Owner's Manual Encore and Eclipse MDE-4625 Graphics Panel Application and Repair Encore and Eclipse PT-1736 CRIND Illustrated Parts Manual Parts Manual PT-1936 Encore Series Pump and Dispenser Illustrated Parts Manual Parts Manual MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Introduction Abbreviations and Acronyms Description ADA American Disabilities Act CRIND Card Reader in Dispenser CSC Contactless Smart Card EMV Chip Cards Euro Plus/Mastercard®/Visa® Chip Cards ESD Electrostatic Discharge PCA Printed Circuit Assembly POS RF TCR Point of Sale Radio Frequency Tribrid Card Reader Transmitter/Receiver in Dispenser TRIND re lim in ar Term MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 3 Important Safety Information Important Safety Information Read the Manual Read, understand and follow this manual and any other labels or related materials supplied with this equipment. If you do not understand a procedure, call a Gilbarco Authorized Service Contractor or call the Gilbarco Support Center at 1-800-800-7498. It is imperative to your safety and the safety of others to understand the procedures before beginning work. Preliminary Precautions You are working in a potentially dangerous environment of flammable fuels, vapors, and high voltage or pressures. Only trained or authorized individuals knowledgeable in the related procedures should install, inspect, maintain or service this equipment. Follow the Regulations Applicable information is available in National Fire Protection Association (NFPA) 30A; Code for Motor Fuel Dispensing Facilities and Repair Garages, NFPA 70; National Electrical Code (NEC), Occupational Safety and Hazard Association (OSHA) regulations and federal, state, and local codes. All these regulations must be followed. Failure to install, inspect, maintain or service this equipment in accordance with these codes, regulations and standards may lead to legal citations with penalties or affect the safe use and operation of the equipment. lim in ! WARNING re Emergency Total Electrical Shut-Off The first and most important information you must know is how to stop all fuel flow to the pump/dispenser and island. Locate the switch or circuit breakers that shut off all power to all fueling equipment, dispensing devices, and Submerged Turbine Pumps (STPs). The EMERGENCY STOP, ALL STOP, and PUMP STOP buttons at the cashier’s station WILL NOT shut off electrical power to the pump/ dispenser. This means that even if you activate these stops, fuel may continue to flow uncontrolled. You must use the TOTAL ELECTRICAL SHUTOFF in the case of an emergency and not the console’s ALL STOP and PUMP STOP or similar keys. Total Electrical Shut-Off Before Access Any procedure that requires access to electrical components or the electronics of the dispenser requires total electrical shut off of that unit. Understand the function and location of this switch or circuit breaker before inspecting, installing, maintaining, or servicing Gilbarco equipment. Evacuating, Barricading and Shutting Off Any procedure that requires access to the pump/dispenser or STPs requires the following actions: • An evacuation of all unauthorized persons and vehicles from the work area • Use of safety tape, cones or barricades at the affected unit (s) • A total electrical shut-off of the affected unit (s) Page 4 ry This section introduces the hazards and safety precautions associated with installing, inspecting, maintaining or servicing this product. Before performing any task on this product, read this safety information and the applicable sections in this manual, where additional hazards and safety precautions for your task will be found. Fire, explosion, electrical shock or pressure release could occur and cause death or serious injury, if these safe service procedures are not followed. Replacement Parts Use only genuine Gilbarco replacement parts and retrofit kits on your pump/dispenser. Using parts other than genuine Gilbarco replacement parts could create a safety hazard and violate local regulations. Safety Symbols and Warning Words This section provides important information about warning symbols and boxes. Alert Symbol This safety alert symbol is used in this manual and on warning labels to alert you to a precaution which must be followed to prevent potential personal safety hazards. Obey safety directives that follow this symbol to avoid possible injury or death. Signal Words These signal words used in this manual and on warning labels tell you the seriousness of particular safety hazards. The precautions below must be followed to prevent death, injury or damage to the equipment: DANGER: Alerts you to a hazard or unsafe practice ! which will result in death or serious injury. WARNING: Alerts you to a hazard or unsafe practice ! that could result in death or serious injury. CAUTION with Alert symbol: Designates a hazard or ! unsafe practice which may result in minor injury. CAUTION without Alert symbol: Designates a hazard or unsafe practice which may result in property or equipment damage. Working With Fuels and Electrical Energy Prevent Explosions and Fires Fuels and their vapors will explode or burn, if ignited. Spilled or leaking fuels cause vapors. Even filling customer tanks will cause potentially dangerous vapors in the vicinity of the dispenser or island. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Important Safety Information In an Emergency No Open Fire Open flames from matches, lighters, welding torches or other sources can ignite fuels and their vapors. re lim in ar No Sparks - No Smoking Sparks from starting vehicles, starting or using power tools, burning cigarettes, cigars or pipes can also ignite fuels and their vapors. Static electricity, including an electrostatic charge on your body, can cause a spark sufficient to ignite fuel vapors. Every time you get out of a vehicle, touch the metal of your vehicle, to discharge any electrostatic charge before you approach the dispenser island. Inform Emergency Personnel Compile the following information and inform emergency personnel: • Location of accident (for example, address, front/back of building, and so on) • Nature of accident (for example, possible heart attack, run over by car, burns, and so on) • Age of victim (for example, baby, teenager, middle-age, elderly) • Whether or not victim has received first aid (for example, stopped bleeding by pressure, and so on) • Whether or not a victim has vomited (for example, if swallowed or inhaled something, and so on) Working Alone It is highly recommended that someone who is capable of rendering first aid be present during servicing. Familiarize yourself with Cardiopulmonary Resuscitation (CPR) methods, if you work with or around high voltages. This information is available from the American Red Cross. Always advise the station personnel about where you will be working, and caution them not to activate power while you are working on the equipment. Use the OSHA Lockout/ Tagout procedures. If you are not familiar with this requirement, refer to this information in the service manual and OSHA documentation. Gasoline ingested may cause unconsciousness and burns to internal organs. Do not induce vomiting. Keep airway open. Oxygen may be needed at scene. Seek medical advice immediately. WARNING Gasoline inhaled may cause unconsciousness and burns to lips, mouth and lungs. Keep airway open. Seek medical advice immediately. Working With Electricity Safely Ensure that you use safe and established practices in working with electrical devices. Poorly wired devices may cause a fire, explosion or electrical shock. Ensure that grounding connections are properly made. Take care that sealing devices and compounds are in place. Ensure that you do not pinch wires when replacing covers. Follow OSHA Lockout/Tagout requirements. Station employees and service contractors need to understand and comply with this program completely to ensure safety while the equipment is down. WARNING Hazardous Materials Some materials present inside electronic enclosures may present a health hazard if not handled correctly. Ensure that you clean hands after handling equipment. Do not place any equipment in the mouth. WARNING Gasoline spilled in eyes may cause burns to eye tissue. Irrigate eyes with water for approximately 15 minutes. Seek medical advice immediately. WARNING Gasoline spilled on skin may cause burns. Wash area thoroughly with clear water. Seek medical advice immediately. WARNING The pump/dispenser contains a chemical known to the State of California to cause cancer. WARNING The pump/dispenser contains a chemical known to the State of California to cause birth defects or other reproductive harm. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 IMPORTANT: Oxygen may be needed at scene if gasoline has been ingested or inhaled. Seek medical advice immediately. Lockout/Tagout Lockout/Tagout covers servicing and maintenance of machines and equipment in which the unexpected energization or start-up of the machine(s) or equipment or release of stored energy could cause injury to employees or personnel. Lockout/Tagout applies to all mechanical, hydraulic, chemical or other energy, but does not cover electrical hazards. Subpart S of 29 CFR Part 1910 - Electrical Hazards, 29 CFR Part 1910.333 contains specific Lockout/ Tagout provision for electrical hazards. Page 5 Installation of the TCR Installation of the TCR Installing the M07999B001 TCR in an Encore S EMV Unit (without Contactless Card Reader Option) Removing the Existing Card Reader ry To remove the existing Card Reader, proceed as follows: lim in Note: Read all instructions before beginning and observe all safety precautions. 1 Obtain an approval from the store manager or responsible personnel to remove the unit from service. 2 Remove AC power to the unit using the station circuit breaker. Refer to MDE-3893 Encore/ Eclipse Owners Manual for details. 3 Remove the lower hydraulics panel. The main door has a lower latch underneath the lower left re main door corner. Open this latch. Locate the upper main door lock. Insert the main door key and open the main door. 4 Repeat step 3 for Side 2 of the unit. 5 Disconnect the cable harness or ribbon cable connection from the Card Reader (see Figure 1 on page 7). 6 Remove the ESD Ground Connection cable from the current Card Reader (if it has one). 7 Use a 1/4 inch nut driver or 1/4 inch ratchet and socket to remove the two Hex head screws (see Figure 1 on page 7) that secure the Card Reader bracket (see Figure 1 on page 7) and the Card Reader to the option door. Dispose of the Card Reader and bracket, unless you want to keep the Card Reader as a used spare part. Note: Make a note of the Card Reader’s gasket orientation. This information will be useful when you install the new Card Reader gasket (M00682B001) and bracket (M07574B001). Also, ensure that the option door has been cleaned with isopropyl alcohol and a clean cloth prior to installing the new Card Reader gasket (M00682B001). 8 Remove the old Card Reader gasket from the option door. Use a putty knife, if required. Page 6 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR Figure 1: Rear View of the Encore S Main Door with Card Reader Cable Harness Connection Fastener re lim in ar Fastener Installing the Encore TCR Assembly To install this assembly, proceed as follows: 1 Remove the adhesive backing from the Card Reader gasket (M00682B001) and place the gasket over the Card Reader opening from the inside of the open main door. CAUTION A properly grounded ESD wrist strap must be worn when performing step 2. Failure to use electrostatic precautions may damage electronic components and void warranty. 2 Obtain the TCR assembly (M07999B001) (see Figure 2 on page 8) from the kit. 3 Remove the 6-pin power/data cable (M07702A006) from the TCR. 4 Install the ESD ground cable on the new Card Reader before securing it to the main door. Insert the connector end of the ESD Ground cable (M07709A001) (see Figure 3 on page 8) to the ESD Ground Connection (see Figure 2 on page 8) on the Card Reader. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 7 Installation of the TCR 5 From the rear of the main door, position the Card Reader and then the Card Reader bracket on the door, such that the Card Reader slot (see Figure 2) is positioned on the top. Loosely secure the Card Reader bracket and Card Reader to the main door using the two Q11677-26 screws (provided in the kit) in the top and bottom two holes (looking from the back of the Card Reader). Note: While installing the Card Reader bracket onto the Card Reader, the lip on the bottom of the bracket should face away from you. Printed Circuit Card (Inside) Card Reader Slot Encore S EMV TCR Assembly (M07999B001) - Front View re Encore S TCR Bracket (M07574B001) lim in ry Figure 2: TCR Assembly and Encore S EMV Bracket Power/Data Connector Antenna Connector ESD Ground Connection Encore S EMV TCR Assembly (M07999B001) - Top View Figure 3: Encore/Eclipse ESD Ground Cable (M07709A001) Connector Ring Terminal 6 Align the Card Reader and bracket. Securely tighten the two mounting screws (Q11677-26). Page 8 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR 7 Reconnect the 6-pin power/data cable (M07702A006) to the 6-pin power/data connector (see Figure 2 on page 8) on the TCR. Note: Tie-wrap the loose end of the cable to ensure that it does not interfere with the other wires. 8 Connect the appropriate end of M07702A006 to P205 and P206 on the Serial Interface PCB (M07793A001) (see Figure 4). P206 (Power to TCR) re lim in ar Figure 4: Connection of the Cable from the Card Reader to P205 and P206 on the Serial Interface PCB (M07793A001) TCR Data Cable Connection to Serial Interface Board P205 (Data Cable to TCR) MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 9 Installation of the TCR re lim in ry Figure 5: Serial Interface PCB (M07793A001) P109 9 Locate the ground ring terminal on the lower portion of the EMV CRIND display mounting bracket and remove the screw that secures the ground connection. Retain the screw for reinstallation. 10 Connect the ring terminal (see Figure 3 on page 8) of the ESD Ground cable (M07709A001) to the EMV CRIND display mounting bracket ground connection. Secure the connection with the screw and lock washer that was removed in step 9. 11 Ensure that all ground cables are secured to the unit with sufficient slack to prevent cable pulls and pinching. Note: A cable from P109 on M07793A001 connects to the Card Reader connection on EMV CRIND display (see Figure 5). Page 10 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR Commissioning the Dispenser/Updating CRIND Software For EMV units, after installing the TCR, you will have to commission the dispenser. At this point, you may also update the EMV CRIND software using the SPOTUpdate tool. For detailed instructions on how to commission the dispenser and update the EMV CRIND software, refer to MDE-4771 EMV CRIND Start-up/Service Manual. re lim in ar Completing the Installation for Encore S EMV Units (without Contactless Card Reader Option) To complete the installation, proceed as follows: 1 Close and secure the main doors using the security latch and the main door lock. Reinstall and lock the lower panel door. 2 Apply the appropriate graphic logos. Refer to MDE-4625 Graphics Panel Application and Repair for graphic application instructions. Note: Graphic logos are order entry items. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 11 Installation of the TCR Installing the M07999B001 TCR in an Encore S EMV Unit (with Contactless Card Reader Option) Removing the Existing Card Reader To remove the existing Card Reader, proceed as follows: Note: Read all instructions before beginning and observe all safety precautions. ry 1 Obtain an approval from the store manager or responsible personnel to remove the unit from service. lim in 2 Remove AC power to the unit using the station circuit breaker. Refer to MDE-3893 Encore/ Eclipse Owners Manual for details. 3 Remove the lower hydraulics panel. The main door has a lower latch underneath the lower left main door corner. Open this latch. Locate the upper main door lock. Insert the main door key and open the main door. re 4 Repeat step 3 for Side 2 of the unit. 5 Disconnect the cable harness or ribbon cable connection from the Card Reader (see Figure 6 on page 13). 6 Remove the ESD Ground Connection cable from the current Card Reader (if it has one). 7 Use a 1/4 inch nut driver or 1/4 inch ratchet and socket to remove the two Hex head screws (see Figure 6 on page 13) that secure the Card Reader bracket (see Figure 6 on page 13) and the Card Reader to the option door. Dispose of the Card Reader and bracket, unless you want to keep the Card Reader as a used spare part. Note: Make a note of the Card Reader’s gasket orientation. This information will be useful when you install the new Card Reader gasket (M00682B001) and bracket (M07574B001). Also, ensure that the option door has been cleaned with isopropyl alcohol and a clean cloth prior to installing the new Card Reader gasket (M00682B001). 8 Remove the old Card Reader gasket from the option door. Use a putty knife, if required. Page 12 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR Figure 6: Rear View of the Encore S Main Door with Card Reader Cable Harness Connection Fastener re lim in ar Fastener Installing the Encore TCR Assembly To install this assembly, proceed as follows: 1 Remove the adhesive backing from the Card Reader gasket (M00682B001) and place the gasket over the Card Reader opening from the inside of the open main door. CAUTION A properly grounded ESD wrist strap must be worn when performing step 2. Failure to use electrostatic precautions may damage electronic components and void warranty. 2 Obtain the TCR assembly (M07999B001) (see Figure 7 on page 14) from the kit. 3 Remove the 6-pin power/data cable (M07702A006) from the TCR. 4 Install the ESD ground cable on the new Card Reader before securing it to the main door. Insert the connector end of the ESD Ground cable (M07709A001) (see Figure 8 on page 14) to the ESD Ground Connection (see Figure 7 on page 14) on the Card Reader. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 13 Installation of the TCR 5 From the rear of the main door, position the Card Reader and then the Card Reader bracket on the door, such that the Card Reader slot (see Figure 7) is positioned on the top. Loosely secure the Card Reader bracket and Card Reader to the main door using the two Q11677-26 screws (provided in the kit) in the top and bottom two holes (looking from the back of the Card Reader). Note: While installing the Card Reader bracket onto the Card Reader, the lip on the bottom of the bracket should face away from you. Printed Circuit Card (Inside) Card Reader Slot Encore S EMV TCR Assembly (M07999B001) - Front View re Encore S TCR Bracket (M07574B001) lim in ry Figure 7: TCR Assembly and Encore S EMV Bracket Power/Data Connector Antenna Connector ESD Ground Connection Encore S EMV TCR Assembly (M07999B001) - Top View Figure 8: Encore/Eclipse ESD Ground Cable (M07709A001) Connector Ring Terminal 6 Align the Card Reader and bracket. Securely tighten the two mounting screws (Q11677-26). Page 14 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR 7 Reconnect the 6-pin power/data cable (M07702A006) to the 6-pin power/data connector (see Figure 7 on page 14) on the TCR. Note: Tie-wrap the loose end of the cable to ensure that it does not interfere with the other wires. 8 Connect the appropriate end of M07702A006 to P205 and P206 on the Serial Interface PCB (M07793A001) (see Figure 9). P206 (Power to TCR) re lim in ar Figure 9: Connection of the Cable from the Card Reader to P205 and P206 on the Serial Interface PCB (M07793A001) TCR Data Cable Connection to Serial Interface Board P205 (Data Cable to TCR) MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 15 Installation of the TCR re lim in ry Figure 10: Serial Interface PCB (M07793A001) P109 9 Locate the ground ring terminal on the lower portion of the EMV CRIND display mounting bracket and remove the screw that secures the ground connection. Retain the screw for reinstallation. 10 Connect the ring terminal (see Figure 8 on page 14) of the ESD Ground cable (M07709A001) to the EMV CRIND display mounting bracket ground connection. Secure the connection with the screw and lock washer that was removed in step 9. 11 Ensure that all ground cables are secured to the unit with sufficient slack to prevent cable pulls and pinching. Note: A cable from P109 on M07793A001 connects to the Card Reader connection on EMV CRIND display (see Figure 10). Page 16 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR Installing the Antenna PCA (M08285A001) The RF antenna must be located directly behind the area where the MasterCard PayPass®, American Express® ExpressPaySM and other logo graphics are attached as shown in Figure 11. Figure 11: Encore S Main Door Showing Antenna PCA Location Front View re lim in ar Encore S E-CIM Rear View PayPass Logo Location Mounting Holes K85492-56 Foam Tape (On the Backside) 2-pin Connector M05170A001 Antenna PCA To install the antenna, proceed as follows: 1 Remove the small bracket holding in the TRIND blanking panel, and knock out the TRIND blanking panel (see Figure 12) using a hammer. Figure 12: Encore S EMV Door with the Blanking Panel Encore S EMV Door with Blanking Panel MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 17 Installation of the TCR 2 Remove the narrow sealing gasket from the exposed TRIND lens space on the outside of the door and replace it with the TRIND gasket (M06010B002). 3 Locate the M08285A001 Antenna PCA placed on the TRIND CSC Reader Lens (M05987B002) and place it over the TRIND gasket. Secure the TRIND CSC Reader Lens by installing and tightening the four screws (M00419B117) (see Figure 13). 4 Connect one end of the M07703A001 Antenna Cable to the Card Reader antenna connector of the TCR top (see Figure 7 on page 14) and the other end of the antenna cable to the 2-pin connector on the M08285A001 PCA antenna (see Figure 11 on page 17). lim in ry Figure 13: Antenna PCA on TRIND CSC Reader Lens re Antenna PCA (M08285A001) TCR TRIND Gasket (M06010B002) 5 Repeat steps 1 to 4 on the other side of the unit. Page 18 MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Installation of the TCR Commissioning the Dispenser/Updating CRIND Software For EMV units, after installing the TCR, you will have to commission the dispenser. At this point, you may also update the EMV CRIND software using the SPOTUpdate tool. For detailed instructions on how to commission the dispenser and update the EMV CRIND software, refer to MDE-4771 EMV CRIND Start-up/Service Manual. re lim in ar Completing the Installation for Encore S Units (with Contactless Card Reader Option) To complete the installation, proceed as follows: 1 Install the N23951-14 FCC Label on the back of the Card Reader as shown in Figure 14. Figure 14: FCC Label on TCR (Side) 2 Close and secure the main doors using the security latch and the main door lock. Reinstall and lock the lower panel door. 3 Test the RF Readers by sliding the CRIND diagnostic card (Q12534) through both the readers with the magnetic strip facing upwards. 4 Pass the Card Reader test card in front of the RF antenna (flat side towards the antenna). 5 Verify if a valid read was made from the test card. The CRIND beeper will emit an audible beep upon performing a successful read. Note: The test card should be read from a minimum distance of 1 inch when presented parallel to the bezel surface. 6 Apply the appropriate graphic logos. Refer to MDE-4625 Graphics Panel Application and Repair for graphic application instructions. Note: Graphic logos are order entry items. MDE-4770 Tribrid Card Reader Installation Manual · June 2008 Page 19 Installation of the TCR lim in ar 7 Obtain the FCC Decal (M02962B011) from the kit and install it under the patent label. re Patent Label TRIND FCC Label Nameplate (M02962B011) American Express® is a registered trademark of American Express Co. CRIND®, Eclipse®, Encore®, Gilbarco®, and TRIND® are registered trademarks of Gilbarco Inc. ExpressPaySM is a service mark of American Express Co. MasterCard® and PayPass® are registered trademarks of MasterCard International, Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Visa® is a registered trademark of Visa International Service Association. © 2008 Gilbarco Inc. 7300 West Friendly Avenue · Post Office Box 22087 Greensboro, North Carolina 27420 Phone (336) 547-5000 · http://www.gilbarco.com · Printed in the U.S.A. MDE-4770 Tribrid Card Reader Installation Manual · June 2008
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes Page Mode : UseOutlines Signing Date : 2008:06:04 09:08:25-04:00 Signing Authority : ARE_Acrobat Collaboration V7.0 P9 0000109 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, Export XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : FrameMaker 7.2 Modify Date : 2008:06:04 09:08:25-04:00 Create Date : 1997:01:09 11:18:10Z Metadata Date : 2008:06:04 09:08:25-04:00 Format : application/pdf Title : MDE-4770 Creator : Gilbarco Inc. Description : MDE-4770 Tribrid Card Reader Installation Manual Document ID : uuid:d2a4d777-0b5e-4e99-9e56-30c22cad4b21 Instance ID : uuid:ac7e2f6a-cbaa-4fd9-81cf-26516f1d327a Has XFA : No Page Count : 20 Subject : MDE-4770 Tribrid Card Reader Installation Manual Author : Gilbarco Inc.EXIF Metadata provided by EXIF.tools