*INST.90J*
INST.90J

90

Surface Overhead Holders
with Angle Bracket for Flush Frame

Installation Instructions

These instructions cover the following models:
90H (Hold Open), 90S (Stop only), 90F (Friction), and 90SE (Special Stop Only)
INSTALLATION NOTES
1. Hollow metal frames should be properly reinforced with a 3/16” (5mm) minimum thickness by 12” (305mm) minimum length plate.
2. Hollow metal doors should be properly reinforced with a 3/16” (5mm) minimum thickness by 2-1/2” (64mm) minimum width plate.
3. Stop only units are permitted on many fire door applications. However, mechanical hold-open devices that
require manual release are not permitted for use on any fire door as outlined on NFPA80® or NFPA101®.
Contact Glynn Johnson or your local representative for assistance.

ADJUSTMENTS
Hold-open tension adjustment (Hold-open model only): Using a
phillips screwdriver, turn screw shown clockwise to increase hold-open
tension and counterclockwise to decrease hold open tension.

Hold-open tension
adjustment screw

Friction adjustment (Friction model only): Using a 3/32” hex wrench,
turn screw shown clockwise to increase friction and counterclockwise to
decrease friction.

1-877-671-7011

www.allegion.com/us

*INST.90J*

Customer Service

INST.90J

Friction
adjustment screw

© Allegion 2014
Printed in U.S.A.
INST.90J Rev. 01/14-b

INSTALLATION STEPS
1

Install angle bracket on closer.
Note: Flip bracket as needed so that
mounting surface is against frame.

2

Determine what type of hinge or pivot is being used on the door.

Angle
bracket

Butt Hinge

When installing closer on pull side of door, use “Pull
Side Mounting Chart” regardless of hinge type and size.
When installing closer on push side of door, find correct
type and size of hinge or pivot on the chart below to
identify correct mounting group to use on chart.
Hinge Type & Size

Butt Hinge 4” Wide
Butt Hinge 4-1/2” Wide
Butt Hinge 5” Wide
Swing Clear Hinge 4” Wide
Swing Clear Hinge 4-1/2” Wide (1-3/4” door)
Swing Clear Hinge 4-1/2” Wide (2” door)
Swing Clear Hinge 4-1/2” Wide (2-1/4” door)
Swing Clear Hinge 5” Wide (1-3/4” door)
Swing Clear Hinge 5” Wide (2” door)
Swing Clear Hinge 5” Wide (2-1/4” door)
Center Hung Pivot (1-3/4” - 2-1/4” doors)
3/4” Offset Pivot (1-3/8” door)
3/4” Offset Pivot (1-3/4” door)
3/4” Offset Pivot (2” or 2-1/4” door)
SOSS 220 (2” or 2-1/4” door)

Offset Pivot

used to locate holder on door and frame.

A

Mounting
Group
3
2
1
1
3
2
1
3
2
1
4
3
2
1
2

Center Hung Pivot

4 Dimensions A, B, and C (shown below) will be

Center line of hinge or pivot

3

Swing Clear Hinge

B

C

5 Using the mounting group and GJ model numbers, find dimensions “A”, “B”, and “C” on page 3 chart.
Notes on using chart:
“Degrees” shown on chart represent desired hold-open degree (on hold-open, friction, and stop only models) or stop
degree (on SE models).
“I” = Arm length from center to center (for reference only).
On hold-open, friction, and stop only models, the dead stop (DS) degree is normally 5-7 degrees beyond the holdopen degree shown on chart. The DS door position is reached when the shock spring is fully compressed.
When installing on doors which open back-to-back, or against a wall or obstruction, it may be desirable to install
the holder based on the dead stop angle rather than the hold-open angle. To do this, add 13/16” (21mm) to the “A”
dimension on chart. This will effectively reduce the dead stop and hold-open by 5-7 degrees. This can only be done
on hold-open, friction, and stop only models, but NOT on SE models.

2

CAUTION: “A” & “B” dimensions are measured from the centerline of hinge, not edge of door.
*Not to be used with swing clear hinges.

Push Side Mounting Chart
85 degrees

90 degrees

95 degrees

100 degrees

105 degrees

110 degrees

95 degrees

100 degrees

105 degrees

110 degrees

Pull Side Mounting Chart
85 degrees

90 degrees

3

6

Mark “B” dimension (from chart) on frame. Note that “B” dimension is measured from centerline of hinge as shown.
Pull side mounting
Hinge/pivot centerline

Hinge/pivot centerline
Door

Frame

Frame

Door

Push side mounting

7

Cut out “Angle Bracket Template” from bottom of page and align on frame to locate 4 holes to drill.

8

Locate and mark “A” and “C” dimensions on door. Note that “A” dimension is measured from centerline of hinge as shown.
For dead stop add 13/16” (21mm) to the “A” dimension from the chart. For more information about dead stop, see page 2
under “Notes on using chart”.

9

Drill two 3/8” (10mm) diameter channel mounting holes through door per chart and dimensions shown below. Mounting
holes should be prepared only after door and frame are installed.
A

B

Pull side mounting

Push side mounting

Center of hinge/pivot

9/16” (14mm)
C

Door
opens

Door
opens

Screw Chart

10 Install jamb bracket on the stop (see Screw Chart).
11 Install the channel on the door (see Screw Chart)

Shock spring should be located on hinge end of the door.

Angle Bracket Template
(actual size)

B
For push side installation, align
top of door here

For pull side installation,
align top of door here

4

1-3/16” (33mm)

QTY
4
Jamb
4
2
Door
2
Angle 4
Brkt.

Screw type
#14 x 1-1/2” FPHSMS
1/4”-20 x 3/4” FPHMS
1/4”-20 x 1-1/4” OPHMS
1/4”-20 x 2-1/2” Sex bolts

Wood Metal

1/4”-20 x 1/2”

4 holes

Metal: #7 Drill, 1/4”-20 tap
Wood: 3/16” pilot hole

B



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2013:12:06 13:14:40-05:00
Metadata Date                   : 2013:12:06 13:14:42-05:00
Modify Date                     : 2013:12:06 13:14:42-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:bade09c7-84db-4028-b8a6-6290e2e7331b
Original Document ID            : xmp.did:516915126ECCE1118A0D8AD340C27D6B
Document ID                     : xmp.id:FFC34C46A25EE311A457C8F694D1C347
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:3F337110CD5DE3118847E8FC14163402
Derived From Document ID        : xmp.did:ED7F4E46944CE3119C08FBE7FC049204
Derived From Original Document ID: xmp.did:516915126ECCE1118A0D8AD340C27D6B
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:12:06 13:14:40-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu