Good Way Technology TD11000Z2 Z-Wave Roller Shutter Controller User Manual

Good Way Technology Co., Ltd. Z-Wave Roller Shutter Controller

User Manual

Download: Good Way Technology TD11000Z2 Z-Wave Roller Shutter Controller User Manual
Mirror Download [FCC.gov]Good Way Technology TD11000Z2 Z-Wave Roller Shutter Controller User Manual
Document ID3966014
Application IDOEW3giZjipoMS7E5WRJebw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize61.99kB (774937 bits)
Date Submitted2018-08-16 00:00:00
Date Available2018-08-16 00:00:00
Creation Date2018-08-14 16:40:52
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-08-14 16:40:52
Document TitleUser Manual
Document CreatorMicrosoft® Word 2016
Document Author: Henry Chen

The Power level Command Class defines RF transmit power
(0x0A)
controlling commands useful when installing or testing a network.
The commands make it possible for supporting controllers to set/get
User's Manual
the RF transmit power level of a node and test specific links between
nodes with a specific RF transmit power level.
Introduction
【BASIC command class】
11
(0x0B)
power
changed
percenta
ge to
send the
power
report
Set the 2
time
interval
of
reporting
watts in
seconds
Set the 2
time
interval
of
reporting
KWH in
seconds
1 - 100: 1% - 100%
0,
300
60 sec
32767
0:Disable
60 - 32767:
60 - 32767sec
0,
3600
60 32767
0:Disable
60 - 32767:
60
- 32767sec
Z-Wave Roller Shutter Controller is an ideal for the remotely electric
Control the roller shutter to be opened or closed after receiving the
motor controller. It is used to control the motors of rollers, shades,
BASIC_SET command.
blinds, venetian blinds and similar sun shade, which are single phase
To be opened:
AC powered. The module can be controlled either through a Z-Wave
[Command Class Multilevel, Multilevel Set, Value = 0xFF]
network or through the wall switch, and measures power
To be closed:
consumption of motor.
[Command Class Multilevel, Multilevel Set, Value= 0x00]
Z-Wave Roller Shutter needs to motor calibration before use, please
To be the percentage of full opened position:
refer to CONFIGURATION command class parameter 0x01. Z-Wave
[Command Class Multilevel, Multilevel Set, Value = 0x01~0x63]
Roller Shutter’s positioning calibration does not apply to motor
【SWITCH MULTILEVEL command class】
without obstacle detection, using this function may cause
Control the roller shutter to be opened, closed, stopped or be the
unpredictable problems, please make sure your motor has obstacle
percentage of full opened position after receiving the SWITCH
detection function before positioning calibration.
MULTILEVEL command.
【ASSOCIATION command class】
To be opened:
The device can be set 1 auto-report ID in Group 1.
[Command Class Multilevel, Multilevel Set, Value = 0xFF]
The device sends an unsolicited command to the configured
To be closed:
destinations when triggered by an event.
[Command Class Multilevel, Multilevel Set, Value= 0x00]
Group1:"Lifeline" :
To be the percentage of full opened position:
【ASSOCIATION GRP INFO command class】
[Command Class Multilevel, Multilevel Set, Value = 0x01~0x63]
The purpose of the Association Group Information (AGI) Command
To be stopped:
Class is to allow a device to report the capabilities of each
[Command Class Multilevel,
association group supported by the device.
SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE]
【SWITCH_BINARY command class】
【CONFIGURATION command class】
Control the roller shutter to be opened or closed after receiving the
This class is used for setting certain vendor specific configuration
SWITCH BINARY command.
variables. See the following table for configuration variables:
Parameter Name Size Range Default
Description
(byte)
value
Positioni 1
0-1 0
0: Disable
(0x01)
ng
1: Executing
Calibratio
calibration
External 1
0-1 0
0: Enable external
(0x02)
switch
switch
Protectio
1: Disable external
switch
When
00
0: Disable automatic
(0x03)
the door
32767
closing
is
1 - 32767: The door
opened,
will be closed
set the
automatically in 1 delay
32767sec
time for
automati
c closing.
When
00
0: Disable automatic
(0x04)
the door
32767
notification
is open,
1 - 32767: The
set the
notification will be
delay
sent automatically in
time for
1 - 32767sec
automati
notificati
on.
Set the 1
0-1 0
0: Roller Shutter
(0x05)
operatio
1: Venetian
n mode
(up/down and slate
rotation)
Set the 1
0-6 0
Angles of blinds
(0x06)
angle of
0:0∘
blinds
1:30∘
2:60∘
3:90∘
4:120∘
5:150∘
6:180∘
Set the 1
0 - 127 15
0:Disable.
(0x07)
slats
(1.5sec 1 - 127: 0.1 - 12.7 sec
turning
time
Set the 1
0 - 127 0
0:No offset time
(0x08)
delay
1 - 127: 0.1 - 12.7 sec
time to
start the
motor up
to the
blade
Set the 1
0 - 127 0
0:No offset time
(0x09)
delay
1 - 127: 0.1 – 12.7 sec
time to
start the
motor
down to
the blade
10
Set the 1
0 - 100 0
0:Disabled
To be opened:
Package Contents
■ Z-Wave Roller Shutter Controller
■ User Manual
x1
x1
Command Class
Device Information
GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
z-wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_Transport_Service_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1
The Below listed Command Class are all supported the S
ecurity S2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION_V1
Detailed description of each command class
【ZWAVEPLUS INFO command class】
The Z-Wave Plus Info Get Command is used to get additional
information of the Z-Wave Plus device in question.
【VERSION command class】
The user can enquire the version of the unit using VERSION_GET
command. It will return VERSION_REPORT Command. Version
Report Command:
[Command Class Version, Version Report, Z-Wave Library Type, ZWave Protocol Version, Z-Wave Protocol Sub Version, Application
Version, Application Sub Version]
【MANUFACTURER SPECIFIC command class】
The user can use the Manufacturer Specific Get Command to request
manufacturer
specific
information
from
another
node.
Manufacturer Specific Report Command:
[Command Class Manufacturer Specific, Manufacturer ID 1,
Manufacturer ID 2, Product Type ID 1, Product Type ID 2, Product ID
1, Product ID 2]
【DEVICE RESET LOCALLY command class】
The Device Reset Locally Command Class is used to notify central
controllers that a Z-Wave device is resetting its network specific
parameters.
【POWERLEVEL command class】
12
(0x0C)
[Command Class SWITCH_BINARY, Set Value = 0xFF]
To be closed:
[Command Class SWITCH_BINARY, Set Value = 0x00]
【METER command class】
The Meter Command Class is intended for Z-Wave enabled devices
capable of reporting energy measurements in addition to any main
functionality or features e.g. an appliance module reporting the
current consumption of the connected load. The Meter command
class not support V1&V2 version. And it will take about 3 seconds to
show the meter report on the request sending device.
【FIRMWARE UPDATE META DATA command class】
Support OTA (On-The-Air) firmware update function.
【COMMAND_CLASS_SECURITY_V1】
【COMMAND_CLASS_SECURITY_2_V1】
This device is a security enabled Z-Wave Plus product that is able to
use encrypted Z-Wave Plus messages to communicate to other
security enabled Z-Wave Plus products.
Product Overview
Product Dimensions
Application Diagram
Main Diagram
Function
Add for Inclusion
- Notes for the Diagram
D1
D2
S1
S2
Pairing Button
Operation
Neutral lead
Live lead
Output for motor UP
Output for motor DOWN
Input for switch/push button UP
Input for switch/push button DOWN
Include/ Exclude/ Reset Button
Device Installation
1. Before installation make sure the voltage supply is disconnected.
2. Put the device into a small box (such as wall box or small plastic
box and etc.) near the motor to avoid direct exposure danger in
the air and to the water.
3. Connect the motor of Roller Shutter and Switch in accordance
with the wiring diagram presented on Fig. 1 (roller blinds,
venetian blinds).
Operation
1. Put the Z-Wave Controller into
inclusion mode, and press the pairing
button 3 times in 2 seconds to include
the module.
2. Put the Z-Wave Controller into
inclusion mode, and press the “external
swtich1” or “external swtich2” 3 times
in 2 seconds to include the module.
Remove for
1. Put the Z-Wave Controller into
Exclusion
exclusion mode, and press the pairing
button 3 times in 2 seconds to exclude
the device.
2. Put the Z-Wave Controller into
inclusion mode, and press the “external
swtich1” or “external swtich2” 3 times
in 2 seconds to include the module.
Reset
1. Press the pairing button 3 times in 2
seconds and press and hold the pairing
button for more than 5 seconds at the
3rd time.
2. The module is excluded and restores to
factory default setting.
3. Then the module will be in autoinclusion mode for 2 minutes.
Please use this procedure only when the
network primary controller is missing or
otherwise inoperable.
Positioning
Positioning calibration is a process during
calibration
which a Roller Shutter learns the position
of the limit switches and a motor
characteristic. Calibration is mandatory in
order for the Roller Shutter to correctly
recognize a roller blind position. The
procedure consists of an automatic, full
movement between the limit switches
(up, down, and up again).
There are three kinds of positioning
calibration operation as follows:
1. Parameter Setting: Parameter 1(0x01),
Size 1(byte), Value 1.
2. Pairing Button: Press and hold the
button for 6 to 10 seconds, release the
button (less than 2 seconds), and then
click the button (less than 2 seconds)
3. External Switch: Use the same external
switch (S1 or S2), turn on and off 3
times. Turn ON =>OFF => ON=> OFF=>
ON=> OFF (Turn ON: lasts 3 to10
seconds), Turn OFF: less than 2
seconds)
Note: If an emergency is encountered
during the positioning calibration process,
please click the external switch, the
pairing button, or the APP to abort the
positioning calibration processes.
Notice: Including a node ID allocated by Z-WaveTM Controller
means “Add” or “Inclusion”. Excluding a node ID allocated by ZWaveTM Controller means “Remove” or “Exclusion”.
LED Indicator
LED Signal
LED OFF
Red & Green blinking by
turns
Solid Green
Figure 1. Roller Shutter wiring diagram
4. Locate the antenna far from metal elements (as far as possible)
5. Do not shorten the antenna.
6. Turn on the power supply keeping the necessary safety
precautions.
7. Include the module into the Z-Wave network, please refer to the
"Operation" section for “Inclusion” operating instructions.
8. Executing the positioning calibration process, please refer to the
"Operation" section for “Positioning calibration” operating
instructions.
CAUTION!
! Read this manual before attempting to install the device! Failure
to observe recommendations included in this manual may be
dangerous or cause a violation of the law. The manufacturer will
not be held responsible for any loss or damage resulting from not
following the instructions of operating manual.
! Any maintenance work on controlled devices may be performed
only after the power supply has been disconnected.
! Do not connect the module to loads exceeding recommended
values. Connect the module only in accordance with the diagram
presented in the manual. Improper connections may be
dangerous.
Green blinking twice per
second for 3 seconds
Red blinking twice per
second for 3 seconds
Green blinking twice per
second for 2 minutes
Red blinking twice per
second
Status
Power OFF
Power ON (No node ID)
Power ON (Included)
(1) Inclusion process success
(2) Exclusion process success
(3) Parameter setting success
(4) Positioning calibration
success
(1) Inclusion process failed
(2) Exclusion process failed
(3) Parameter setting failed
(4) Positioning calibration
failed
Auto Inclusion Mode
Overload Protection
Specification
Wireless Type
Frequency
Operating Distance
Power Supply
Rated load current of AC
output (resistive load)
Rated power of Motor
Power measurement
accuracy
Electricity Consumption
Z-Wave Plus
EU: 868.4 MHz
US: 916.0 MHz
up to 100m outdoors ;
up to 30m indoors
110 -230 VAC ±10% 50 / 60 Hz
2 @ 5A (230 VAC)
Motor under 170W
P = 0-40 W, ± 2 W; P > 40 W, ±3%
<0.5W
LED
Red /Green LED*1
Switching
Relay x 2
Data Rate
100 kbps
Operation temperature
-10°C ~ 40°C
Dimensions (L x W x H)
45.5 x 44.8 x 20.3 mm
*Specification is subject to change without prior notice.
External Switch Operation
S1
Turn OFF
Turn ON
Turn OFF
Turn ON
S2
Turn OFF
Turn OFF
Turn ON
Turn ON
Motor Action
STOP
UP
DOWN
STOP
Regulatory Compliance
CE Caution
Electromagnetic compatibility and Radio spectrum Matters (ERM);
Short Range Devices (SRD); Radio equipment to be used in the 25
MHz to 1,000 MHz frequency range with power levels ranging up to
500 mW; Part 2: Harmonized EN covering essential requirements
under article 3.2 of the R&TTE Directive.
FCC Caution
This device complies with Part 15 of the FCC rules standard.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance could void the authority to operate
equipment. This device and its antenna must not be co-located or
operating in conjunction with any other antenna or transmitter. This
equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed
and operated with minimum distance 20cm between the radiator &
your body. This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
WEEE Information
For EU (European Union) member users: According to the WEEE
(Waste electrical and electronic equipment) Directive, do not
dispose of this product as household waste or commercial waste.
Waste electrical and electronic equipment should be appropriately
collected and recycled as required by practices established for your
country.
For information on recycling of this product, please contact your
local authorities, your household waste disposal service or the shop
where you purchased the product.
Z-Wave Plus
This product can be included and operated in any Z-Wave network
with other Z-Wave certified devices from other manufacturers
and/or other applications. All non-battery operated nodes within
the network will act as repeaters regardless of vendor to increase
reliability of the network.
This device must be used in conjunction with a Security Enabled ZWave Controller in order to fully utilize all implemented functions.
Security S2
Security S2 is supported with the Authenticated and
UnAuthenticated levels of security. The Authenticated level requires
the user to enter the PIN code or QR code printed on the box of the
Roller Shutter. The UnAuthenticated level does not require the PIN
code. Both security levels will encrypt nearly all communication
using AES-128 encryption to ensure reliable and secure
communication.
SmartStart
Sigma Designs technology makes installation easy and secure. Simply
install Roller Shutter into a wall and it will automatically attempt to
join the Z-Wave network. During the inclusion process, your home
automation system will ask for a PIN code or to scan a QR code. The
pin code is printed on the back of Roller Shutter along with the QR
code. Simply enter the PIN code or scan the QR code with a
compatible device. Each QR code is unique for every device.
SmartStart uses the latest Security S2 encryption technology for all
radio communication. It is completely backwards compatible with
non-SmartStart systems if your home automation system doesn’t
support it yet.
Ex:
WARNING: Important safety instructions.
It is important for the safety of persons to follow these instructions.
Save these instructions.
- Important safety instructions. Follow all instructions, since
incorrect installation can lead to severe injury
- All wiring interconnecting with this controller is non-isolated
hazardous live parts.
- The appliance is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given
supervision or instruction.
- Frequently examine the installation for imbalance and signs of
wear or damage to cables and springs.
- Do not use if repair or adjustment is necessary.
- Do not allow children to play with fixed controls. Keep remote
controls away from children.
- The drive shall be disconnected from its power source during
cleaning, maintenance and when replacing parts.
- Indoor use only.
- Never install independent switch for each S1 and S2, to
prevent the activation on D1 and D2 at the same time.
- Material used only for the 16 AWG copper wires and the
suggested strip length is 4.5 ~ 5 mm.
- Equipment shall not be interconnected with the output of
another power source.
- High Voltage - Disconnect power supply before servicing.
- Risk of Electric Shock - More than one disconnect switch may
be required to de-energize the device before servicing.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Language                        : zh-TW
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Creator                         : Henry Chen
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2018:08:14 16:40:52+08:00
Modify Date                     : 2018:08:14 16:40:52+08:00
Document ID                     : uuid:9C3D1D45-65B4-469E-88E0-D6D35147624B
Instance ID                     : uuid:9C3D1D45-65B4-469E-88E0-D6D35147624B
Author                          : Henry Chen
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SW8TD11000Z2

Navigation menu