Good Way Technology TD13000Z2 Z-Wave In-Wall Power Monitor Switch User Manual

Good Way Technology Co., Ltd. Z-Wave In-Wall Power Monitor Switch

User Manual

Download: Good Way Technology TD13000Z2 Z-Wave In-Wall Power Monitor Switch User Manual
Mirror Download [FCC.gov]Good Way Technology TD13000Z2 Z-Wave In-Wall Power Monitor Switch User Manual
Document ID3965960
Application IDKkNUqUvFvvE3S2g7JCJENw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.96kB (611961 bits)
Date Submitted2018-08-16 00:00:00
Date Available2018-08-16 00:00:00
Creation Date2018-08-02 14:52:00
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-08-14 18:35:08
Document TitleUser Manual
Document CreatorMicrosoft® Word 2016
Document Author: henry_chen

The Basic Command Class allows a controlling device to operate the
【COMMAND_CLASS_VERSION】
primary functionality of another device without any further knowledge.
The Version Command Class, version 3 allows supporting nodes to
The Basic Command Class ensures a basic interoperability if no other
advertise capabilities related to the Version Command Class and optionally
Command Class is shared by two devices.
provide a detailed list of information regarding implementation on the Z-
【COMMAND_CLASS_METER】
Wave chip.
The Meter Command Class is intended for Z-Wave enabled devices capable
【COMMAND_CLASS_MANUFACTURER_SPECIFIC】
of reporting energy measurements in addition to any main functionality or
Manufacturer Specific Command Class, version 2 adds a set of commands
This In-wall Power Monitor Switch is a transceiver which is a Z-Wave
features e.g. an appliance module reporting the current consumption of
to communicate unique identification, e.g. the serial number, of the
enabled device and is fully compatible with any Z-Wave enabled network.
the connected load. This command class is not intended for residential
product. Commands not mentioned here remains unchanged as specified
Mini-sized design makes it easy to place the In-wall Power Monitor Switch
utility sub-metering such as a water meter counting total consumption.
for
into the wall box and fit in the house decoration.
And it will take about 3 seconds to show the meter report on the request
【COMMAND_CLASS_SECURITY】
There are many kinds of applications using the In-wall Power Monitor
sending device.
The Security Command Class create the foundation for secure application
Switch to switch AC power On and Off for general purpose. The patent
【COMMAND_CLASS_CONFIGURATION】
communication between nodes in a Z-Wave network. The security layer
issued smart relay zero crossing calibration technology can extend the
The Configuration Command Class allows product specific configuration
provides confidentiality, authentication and replay attack robustness
device working life.
parameters to be changed.
through AES-128.
The In-wall Power Monitor Switch is able to detect Instant power wattage
This class is used for setting certain vendor specific configuration variables.
【COMMAND_CLASS_SECURITY_2】
(AC 110~230V) and overloaded wattage (550W/1150W) of the connected
See the following table for configuration variables:
ID Name
Size Range Default
value Description
1 D1
0~
0 : Disable (Default)
automatically
32767
1~32767 : Time in second
turn off
that the O2 will turn off
automatically.
2 D2
0~
0 : Disable (Default)
automatically
32767
1~32767: Time in second
turn off
that the O2 will turn off
automatically.
3 Switch Type 1
0~2
0 : Toggle switches (Default)
1 : Toggle switches with
memory
2 : Momentary switch
4 Reload power 1
0~1
0 : device does not
status
memorize its status at
power cut. Load is
disconnected (Default)
1 : device memorizes its
status at the power cut.
Load will be set to the status
from before power cut.
5 Power
0~100 10
0 : Disabled
reporting on
1~100 : 1 % ~ 100 %.
power change
(Default = 10%)
6 Watts auto- 2
0,
300
0 : Disabled
report period
60~
1~32767Seconds. (Default =
300 Seconds)
32767
7 KWH auto2
0,
3600 0 : Disabled
report period
60~
Set time interval of reporting
KWH (0 ~32767) in seconds.
32767
8 D1
0~
0 : Disable (Default)
automatically
32767
1~32767 : Time in second
turn on
that the O2 will turn on
automatically.
9 D2
0~
0 : Disable (Default)
automatically
32767
1~32767: Time in second
turn on
that the O2 will turn on
automatically.
The Security 2 Command Class is a framework for allowing nodes to
【COMMAND_CLASS_ASSOCIATION】
COMMAND_CLASS_ASSOCIATION,
In-wall Power Monitor Switch
User’s Manual
Introduction
appliances. When the overloaded state is detected, the In-wall Power
Monitor Switch will be disabled, the On/Off button will be locked out, and
the LED light will flash red and green quickly by turns. Disconnect and reconnect the power of the In-wall Power Monitor Switch will reset its
overloaded condition to the normal status.
In-wall Switch is also a security Z-Wave device and supports the Over The
Air (OTA) feature for the product’s firmware upgrade. If you want your Inwall Switch to be a security device that use secure/encrypted message to
communicate in a Z-Wave network, then a security enabled Z-Wave
controller is needed.
Package contents
 In-wall Power Monitor Switch
x1
 User manual
x1
Command class
In-Wall Power Switch Command Class Supported
COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
COMMAND_CLASS_SWITCH_BINARY_V1,
COMMAND_CLASS_METER_V3,
COMMAND_CLASS_CONFIGURATION_V1,
COMMAND_CLASS_ASSOCIATION_V2,
The Association Command Class is used to manage associations to NodeID
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
destinations. A NodeID destination may be a simple device or the Root
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Device of a Multi Channel device.
Group
Name
Description
"Lifeline"
Reports the device status and allows for
assigning single device only (main
controller by default).
”alarm EP 1”
It is assigned to switch connected to the
S1 terminal (uses Notification command
class)
”Switch 1”
It is assigned to switch connected to the
S1 terminal (uses Basic command class)
”alarm EP 2”
It is assigned to switch connected to the
S1 terminal (uses Notification command
class)
”Switch 2”
It is assigned to switch connected to the
S1 terminal (uses Basic command class)
Security
The group allows to control 5 regular or multichannel devices per an
COMMAND_CLASS_SWITCH_BINARY_V1,
association group.
COMMAND_CLASS_METER_V3,
【COMMAND_CLASS_ASSOCIATION_GRP_INFO】
COMMAND_CLASS_CONFIGURATION_V1,
The Association Group Information (AGI) Command Class allows a node to
COMMAND_CLASS_ASSOCIATION_V2,
advertise the capabilities of each association group supported by a given
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
application resource. Controllers and installer tools SHOULD use AGI
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1,
information to support controller-assisted button-to-button association
COMMAND_CLASS_NOTIFICATION_V8,
and GUI-based drag-and-drop association in a plug-and-play fashion.
COMMAND_CLASS_VERSION_V3,
Centralized gateway-based deployments may create a single association
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2,
from the lifeline association group to a central management application.
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
【COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION】
COMMAND_CLASS_POWERLEVEL_V1,
The Multi Channel Association Command Class is used to manage
COMMAND_CLASS_MULTI_CHANNEL_V4,
associations to Multi Channel End Point destinations as well as to NodeID
COMMAND_CLASS_SUPERVISION_V1,
destinations.
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
【COMMAND_CLASS_NOTIFICATION】
In-Wall Power Switch Device Information
The Notification Command Class is used to advertise events or states, such
Basic Device Class: ROUTING_SLAVE
as movement detection, door open/close or system failure. The
Generic Device Class: SWITCH_BINARY
Notification Command Class supersedes the Alarm Command Class.
Notification Type
Notification events
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2,
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
COMMAND_CLASS_POWERLEVEL_V1,
COMMAND_CLASS_SECURITY_V1,
COMMAND_CLASS_SECURITY_2_V1,
COMMAND_CLASS_MULTI_CHANNEL_V4,
COMMAND_CLASS_SUPERVISION_V1,
Specific Device Class: POWER_STRIP
Detailed description of each command class
【COMMAND_CLASS_ZWAVEPLUS_INFO】
0x08
(Power Management)
The Z-Wave Plus Info Get Command is used to get additional information
of the Z-Wave Plus device in question.
Manufacturer
Specific
Command
Class,
Version
2.
communicate securely in a Z-Wave network. The Security 2 Command
Class provides backwards compatibility to nodes implementing the
Security 0 Command Class. Security 2 Command Class also defines a new
encapsulation format, new Security Classes and a new KEX Scheme 1,
which together offers a number of advantages over the Security 0
Command Class. Security 2 Command Class is scalable and allows more
KEX Schemes, Security Classes and encapsulation formats to be introduced
in the future if necessary.
【COMMAND_CLASS_MULTI_CHANNEL】
The Multi Channel command class is used to address one or more end
points in a Multi Channel device. An application implementing this
command class MUST set the Optional Functionality bit in the NIF.
A Multi Channel device MAY implement from 1 to 127 end points.
A controlling devices MAY use Multi Channel encapsulation to
communicate with Multi Channel End Points in other devices. If such a
controlling device does not implement any End Points, the device SHOULD
NOT advertise the Multi Channel Command Class in the Node Information
Frame.
Command Class Supported
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SUPERVISION,
【COMMAND_CLASS_SUPERVISION】
The Supervision Command Class allows a sending node to request
application-level delivery confirmation from a receiving node. The delivery
confirmation includes relevant application-level status information in the
confirmation message. The Supervision Command Class MAY be used for
solitary commands such as Set and unsolicited Report commands.
The Supervision Command Class MUST NOT be used for session-like
command flows such as Get←→Report command exchanges or firmware
update.
【DEVICE RESET LOCALLY command class】
The Device Reset Locally Command Class is used to notify central
controllers that a Z-Wave device is resetting its network specific
parameters.
Device Installation
1.
Put the In-wall Power Monitor Switch into a wall box and connect the
AC power wire L/N to the In-wall Power Monitor Switch connector
L/N.
2.
0x00
(Previous event clear)
0x06
(Over-current detected)
【COMMAND_CLASS_SWITCH_BINARY】
illustrated in the above picture.
3.
【COMMAND_CLASS_TRANSPORT_SERVICE】
supporting nodes.
The Transport Service Command Class supports the transfer of datagrams
【COMMAND_CLASS_BASIC】
larger than the Z-Wave frame.
To manually turn ON the Switch:
Press and release the ON/OFF button. The LED will light ON for 1
second, and the load plugged into the Switch will be turned ON.
4.
To manually turn OFF the Switch:
Press and release the ON/OFF button. The LED will light ON for 1
second, and the load plugged into the Switch will be turned OFF.
NOTE:
1.
The Binary Switch Command Class is used to control the On/Off state of
Connect the wall switch to the In-wall Power Monitor Switch as
Please pull out the antenna and keep it straight to ensure the
reception quality of the signals.
2.
Do not use the wall switch with nightlight functions, or the In-wall
Power Monitor Switch might not work properly.
LED Indicator
Product Overview
Regulatory Compliance
STATUS
No node ID (Before Inclusion)
Power ON(No node ID)
Power Off(No node ID)
SIGNAL
CE Caution
1-second Red LED /
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short
1-second Green LED
Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1,000
Green Light on /
MHz frequency range with power levels ranging up to 500 mW; Part 2:
1-second Red LED
Harmonized EN covering essential requirements under article 3.2 of the
R&TTE Directive.
1-second Red LED /
1-second Green LED
Add for Inclusion - Touch
Green LED Flash and Z-Wave
Three Time(<1Sec. Must
Inclusion
release)
Remove for Exclusion - Touch
Green LED Flash and Z-Wave
Three Time(<1Sec. Must
Exclusion
release)
Reset
Press the pairing button 3 times
in 2 seconds and press and hold
the pairing button for more than
5 seconds at the 3rd time.
The module is excluded and
restores
Application Diagram
to
factory
default
setting.
Main Diagram
Then the module will be in auto-
The on-site environment: One load of lamp, and two wall switches. Two
inclusion mode for 2 minutes.
wall switches can control one identical lamp. This is the Tandem Switch.
Please use this procedure only
To achieve the purpose: Insert our In-wall Power Monitor Switch, and it
when
will not affect the 2 current wall switches controlling the same lamp.
controller is missing or otherwise
the
network
primary
inoperable.
Power ON( Z-Wave Connect)
Green LED on & Red LED turn off
Power Off( Z-Wave Connect)
Green LED & Red LED turn off
Over load Protect
Red LED every 0.5 second Flash
FCC Caution
This device complies with Part 15 of the FCC rules standard. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance could void the authority to operate equipment.
This device and its antenna must not be co-located or operating in
conjunction with any other antenna or transmitter. This equipment
complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body. This
equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Notice: Including a node ID allocated by Z-WaveTM Controller means
“Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM
WEEE Information
Controller means “Remove” or “Exclusion”.
For EU (European Union) member users: According to the WEEE (Waste
electrical and electronic equipment) Directive, do not dispose of this
Support Z-Wave RF Package Communication
FUNCTION
DESCRIPTION
product as household waste or commercial waste. Waste electrical and
electronic equipment should be appropriately collected and recycled as
Allows Association to control
Combine other Slave devices
required by practices established for your country.
the Controller
to interlock simultaneously,
For information on recycling of this product, please contact your local
Glossary of terms
able to connect up to 5
authorities, your household waste disposal service or the shop where you
Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds
devices.
purchased the product
N - NEUTRAL wire
D2 - Device 2
N - NEUTRAL wire
Support Set-time for
This function is to report the
L - LIVE wire
S1 - Switch 1
L - LIVE wire
specific controller
status to the controller on the set
Z-Wave Plus
NOTE:
time. The fifth association is used
This product can be included and operated in any Z-Wave network with
1.
The Resistive load of single S1 or S2 is 5A at max., while the total
to report to the controller after
other Z-Wave certified devices from other manufacturers and/or other
Resistive load of S1 plus S2 is 1150W at max., too.
the node status is changed.
applications. All non-battery operated nodes within the network will act as
YES
repeaters regardless of vendor to increase reliability of the network.
2.
In the range of 1150W, you can make any permutations. However,
Support Z-Wave to read
when S1 is set to 1150W (the maximum of load), S2 can only be 0W,
Device Detect status and
and vice versa.
report
2.
Controller in order to fully utilize all implemented functions.
Specification
Basic Application Diagram
1.
This device must be used in conjunction with a Security Enabled Z-Wave
Connect S2 to one switch, you can control the device connected to
Security S2
ITEM
DESCRIPTION
D2.
Power Mode
Self Power
Connect S1 to one switch, you can control the device connected to
Power Range
110 ~ 230 VAC ± 10%
D1.
Power Consumption
Under 0.5W
(Standby Mode)
Frequency
868.42 MHz (EU)
916.00 MHz (US)
922.50 MHz (JP)
Rated load current of AC
output (resistive load)
Load 2
levels of security. The Authenticated level requires the user to enter the
50/60Hz
PIN code or QR code printed on the box of the in wall switch. The
UnAuthenticated level does not require the PIN code. Both security levels
will encrypt nearly all communication using AES-128 encryption to ensure
reliable and secure communication.
SmartStart
Sigma Designs technology makes installation easy and secure. Simply
2 @ 5A
Output circuit power of AC
2 @ 1150 W (230 VAC)
output (resistive load)
2 @ 550 W (110 VAC)
Power measurement accuracy
P = 0 ~ 200W, +/- 2W;
P > 200W, +/- 3%
Load 1
Security S2 is supported with the Authenticated and UnAuthenticated
install In-wall Power Monitor Switch into a wall and it will automatically
attempt to join the Z-Wave network. During the inclusion process, your
home automation system will ask for a PIN code or to scan a QR code. The
pin code is printed on the back of In-Wall Power Monitor Switch along with
the QR code. Simply enter the PIN code or scan the QR code with a
compatible device. Each QR code is unique for every device. SmartStart
Overload Current Protection
5A
LED Indicator
Red/Green * 1
communication. It is completely backwards compatible with non-
Button
Inclusion / Exclusion
Protocol
Z-Wave Plus
SmartStart systems if your home automation system doesn’t support it yet.
Ex:
Data Rate
100 kbps
Operation Range
100 feet (About 30M)
Application
Indoor use
Operation Temperature
-10℃ ~ + 40℃
User Interface (Cable)
16AWG * 6
Housing
PC+ABS
Dimensions (L*W*H)
45.5 x 44.8 x 20.3 mm
uses the latest Security S2 encryption technology for all radio
WARNING: Important safety instructions.
It is important for the safety of persons to follow these instructions. Save
these instructions.
- Important safety instructions. Follow all instructions, since incorrect
installation can lead to severe injury
- All wiring interconnecting with this controller is non-isolated
hazardous live parts.
- The appliance is not to be used by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction.
- Frequently examine the installation for imbalance and signs of wear
or damage to cables and springs.
- Do not use if repair or adjustment is necessary.
- Do not allow children to play with fixed controls. Keep remote
controls away from children.
- The drive shall be disconnected from its power source during
cleaning, maintenance and when replacing parts.
- Indoor use only.
- Never install independent switch for each S1 and S2, to prevent the
activation on D1 and D2 at the same time.
- Material used only for the 16 AWG copper wires and the suggested
strip length is 4.5 ~ 5 mm.
- Equipment shall not be interconnected with the output of another
power source.
- High Voltage - Disconnect power supply before servicing.
- Risk of Electric Shock - More than one disconnect switch may be
required to de-energize the device before servicing.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : henry_chen
Create Date                     : 2018:08:02 14:52:00+08:00
Modify Date                     : 2018:08:14 18:35:08+08:00
Language                        : zh-TW
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Producer                        : Microsoft® Word 2016
Format                          : application/pdf
Creator                         : henry_chen
Creator Tool                    : Microsoft® Word 2016
Metadata Date                   : 2018:08:14 18:35:08+08:00
Document ID                     : uuid:769FF832-CDDC-40D4-9C79-F89AFB4F8D53
Instance ID                     : uuid:f682147a-4ffb-482d-ba1f-df125b63685c
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SW8TD13000Z2

Navigation menu