Good Way Technology TD13000Z2 Z-Wave In-Wall Power Monitor Switch User Manual
Good Way Technology Co., Ltd. Z-Wave In-Wall Power Monitor Switch
User Manual
The Basic Command Class allows a controlling device to operate the 【COMMAND_CLASS_VERSION】 primary functionality of another device without any further knowledge. The Version Command Class, version 3 allows supporting nodes to The Basic Command Class ensures a basic interoperability if no other advertise capabilities related to the Version Command Class and optionally Command Class is shared by two devices. provide a detailed list of information regarding implementation on the Z- 【COMMAND_CLASS_METER】 Wave chip. The Meter Command Class is intended for Z-Wave enabled devices capable 【COMMAND_CLASS_MANUFACTURER_SPECIFIC】 of reporting energy measurements in addition to any main functionality or Manufacturer Specific Command Class, version 2 adds a set of commands This In-wall Power Monitor Switch is a transceiver which is a Z-Wave features e.g. an appliance module reporting the current consumption of to communicate unique identification, e.g. the serial number, of the enabled device and is fully compatible with any Z-Wave enabled network. the connected load. This command class is not intended for residential product. Commands not mentioned here remains unchanged as specified Mini-sized design makes it easy to place the In-wall Power Monitor Switch utility sub-metering such as a water meter counting total consumption. for into the wall box and fit in the house decoration. And it will take about 3 seconds to show the meter report on the request 【COMMAND_CLASS_SECURITY】 There are many kinds of applications using the In-wall Power Monitor sending device. The Security Command Class create the foundation for secure application Switch to switch AC power On and Off for general purpose. The patent 【COMMAND_CLASS_CONFIGURATION】 communication between nodes in a Z-Wave network. The security layer issued smart relay zero crossing calibration technology can extend the The Configuration Command Class allows product specific configuration provides confidentiality, authentication and replay attack robustness device working life. parameters to be changed. through AES-128. The In-wall Power Monitor Switch is able to detect Instant power wattage This class is used for setting certain vendor specific configuration variables. 【COMMAND_CLASS_SECURITY_2】 (AC 110~230V) and overloaded wattage (550W/1150W) of the connected See the following table for configuration variables: ID Name Size Range Default value Description 1 D1 0~ 0 : Disable (Default) automatically 32767 1~32767 : Time in second turn off that the O2 will turn off automatically. 2 D2 0~ 0 : Disable (Default) automatically 32767 1~32767: Time in second turn off that the O2 will turn off automatically. 3 Switch Type 1 0~2 0 : Toggle switches (Default) 1 : Toggle switches with memory 2 : Momentary switch 4 Reload power 1 0~1 0 : device does not status memorize its status at power cut. Load is disconnected (Default) 1 : device memorizes its status at the power cut. Load will be set to the status from before power cut. 5 Power 0~100 10 0 : Disabled reporting on 1~100 : 1 % ~ 100 %. power change (Default = 10%) 6 Watts auto- 2 0, 300 0 : Disabled report period 60~ 1~32767Seconds. (Default = 300 Seconds) 32767 7 KWH auto2 0, 3600 0 : Disabled report period 60~ Set time interval of reporting KWH (0 ~32767) in seconds. 32767 8 D1 0~ 0 : Disable (Default) automatically 32767 1~32767 : Time in second turn on that the O2 will turn on automatically. 9 D2 0~ 0 : Disable (Default) automatically 32767 1~32767: Time in second turn on that the O2 will turn on automatically. The Security 2 Command Class is a framework for allowing nodes to 【COMMAND_CLASS_ASSOCIATION】 COMMAND_CLASS_ASSOCIATION, In-wall Power Monitor Switch User’s Manual Introduction appliances. When the overloaded state is detected, the In-wall Power Monitor Switch will be disabled, the On/Off button will be locked out, and the LED light will flash red and green quickly by turns. Disconnect and reconnect the power of the In-wall Power Monitor Switch will reset its overloaded condition to the normal status. In-wall Switch is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. If you want your Inwall Switch to be a security device that use secure/encrypted message to communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed. Package contents In-wall Power Monitor Switch x1 User manual x1 Command class In-Wall Power Switch Command Class Supported COMMAND_CLASS_ZWAVEPLUS_INFO_V2, COMMAND_CLASS_SWITCH_BINARY_V1, COMMAND_CLASS_METER_V3, COMMAND_CLASS_CONFIGURATION_V1, COMMAND_CLASS_ASSOCIATION_V2, The Association Command Class is used to manage associations to NodeID COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3, destinations. A NodeID destination may be a simple device or the Root COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 Device of a Multi Channel device. Group Name Description "Lifeline" Reports the device status and allows for assigning single device only (main controller by default). ”alarm EP 1” It is assigned to switch connected to the S1 terminal (uses Notification command class) ”Switch 1” It is assigned to switch connected to the S1 terminal (uses Basic command class) ”alarm EP 2” It is assigned to switch connected to the S1 terminal (uses Notification command class) ”Switch 2” It is assigned to switch connected to the S1 terminal (uses Basic command class) Security The group allows to control 5 regular or multichannel devices per an COMMAND_CLASS_SWITCH_BINARY_V1, association group. COMMAND_CLASS_METER_V3, 【COMMAND_CLASS_ASSOCIATION_GRP_INFO】 COMMAND_CLASS_CONFIGURATION_V1, The Association Group Information (AGI) Command Class allows a node to COMMAND_CLASS_ASSOCIATION_V2, advertise the capabilities of each association group supported by a given COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3, application resource. Controllers and installer tools SHOULD use AGI COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1, information to support controller-assisted button-to-button association COMMAND_CLASS_NOTIFICATION_V8, and GUI-based drag-and-drop association in a plug-and-play fashion. COMMAND_CLASS_VERSION_V3, Centralized gateway-based deployments may create a single association COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, from the lifeline association group to a central management application. COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1, 【COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION】 COMMAND_CLASS_POWERLEVEL_V1, The Multi Channel Association Command Class is used to manage COMMAND_CLASS_MULTI_CHANNEL_V4, associations to Multi Channel End Point destinations as well as to NodeID COMMAND_CLASS_SUPERVISION_V1, destinations. COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 【COMMAND_CLASS_NOTIFICATION】 In-Wall Power Switch Device Information The Notification Command Class is used to advertise events or states, such Basic Device Class: ROUTING_SLAVE as movement detection, door open/close or system failure. The Generic Device Class: SWITCH_BINARY Notification Command Class supersedes the Alarm Command Class. Notification Type Notification events COMMAND_CLASS_NOTIFICATION_V8, COMMAND_CLASS_TRANSPORT_SERVICE_V2, COMMAND_CLASS_VERSION_V3, COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1, COMMAND_CLASS_POWERLEVEL_V1, COMMAND_CLASS_SECURITY_V1, COMMAND_CLASS_SECURITY_2_V1, COMMAND_CLASS_MULTI_CHANNEL_V4, COMMAND_CLASS_SUPERVISION_V1, Specific Device Class: POWER_STRIP Detailed description of each command class 【COMMAND_CLASS_ZWAVEPLUS_INFO】 0x08 (Power Management) The Z-Wave Plus Info Get Command is used to get additional information of the Z-Wave Plus device in question. Manufacturer Specific Command Class, Version 2. communicate securely in a Z-Wave network. The Security 2 Command Class provides backwards compatibility to nodes implementing the Security 0 Command Class. Security 2 Command Class also defines a new encapsulation format, new Security Classes and a new KEX Scheme 1, which together offers a number of advantages over the Security 0 Command Class. Security 2 Command Class is scalable and allows more KEX Schemes, Security Classes and encapsulation formats to be introduced in the future if necessary. 【COMMAND_CLASS_MULTI_CHANNEL】 The Multi Channel command class is used to address one or more end points in a Multi Channel device. An application implementing this command class MUST set the Optional Functionality bit in the NIF. A Multi Channel device MAY implement from 1 to 127 end points. A controlling devices MAY use Multi Channel encapsulation to communicate with Multi Channel End Points in other devices. If such a controlling device does not implement any End Points, the device SHOULD NOT advertise the Multi Channel Command Class in the Node Information Frame. Command Class Supported COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_METER, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION, COMMAND_CLASS_SUPERVISION, 【COMMAND_CLASS_SUPERVISION】 The Supervision Command Class allows a sending node to request application-level delivery confirmation from a receiving node. The delivery confirmation includes relevant application-level status information in the confirmation message. The Supervision Command Class MAY be used for solitary commands such as Set and unsolicited Report commands. The Supervision Command Class MUST NOT be used for session-like command flows such as Get←→Report command exchanges or firmware update. 【DEVICE RESET LOCALLY command class】 The Device Reset Locally Command Class is used to notify central controllers that a Z-Wave device is resetting its network specific parameters. Device Installation 1. Put the In-wall Power Monitor Switch into a wall box and connect the AC power wire L/N to the In-wall Power Monitor Switch connector L/N. 2. 0x00 (Previous event clear) 0x06 (Over-current detected) 【COMMAND_CLASS_SWITCH_BINARY】 illustrated in the above picture. 3. 【COMMAND_CLASS_TRANSPORT_SERVICE】 supporting nodes. The Transport Service Command Class supports the transfer of datagrams 【COMMAND_CLASS_BASIC】 larger than the Z-Wave frame. To manually turn ON the Switch: Press and release the ON/OFF button. The LED will light ON for 1 second, and the load plugged into the Switch will be turned ON. 4. To manually turn OFF the Switch: Press and release the ON/OFF button. The LED will light ON for 1 second, and the load plugged into the Switch will be turned OFF. NOTE: 1. The Binary Switch Command Class is used to control the On/Off state of Connect the wall switch to the In-wall Power Monitor Switch as Please pull out the antenna and keep it straight to ensure the reception quality of the signals. 2. Do not use the wall switch with nightlight functions, or the In-wall Power Monitor Switch might not work properly. LED Indicator Product Overview Regulatory Compliance STATUS No node ID (Before Inclusion) Power ON(No node ID) Power Off(No node ID) SIGNAL CE Caution 1-second Red LED / Electromagnetic compatibility and Radio spectrum Matters (ERM); Short 1-second Green LED Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1,000 Green Light on / MHz frequency range with power levels ranging up to 500 mW; Part 2: 1-second Red LED Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive. 1-second Red LED / 1-second Green LED Add for Inclusion - Touch Green LED Flash and Z-Wave Three Time(<1Sec. Must Inclusion release) Remove for Exclusion - Touch Green LED Flash and Z-Wave Three Time(<1Sec. Must Exclusion release) Reset Press the pairing button 3 times in 2 seconds and press and hold the pairing button for more than 5 seconds at the 3rd time. The module is excluded and restores Application Diagram to factory default setting. Main Diagram Then the module will be in auto- The on-site environment: One load of lamp, and two wall switches. Two inclusion mode for 2 minutes. wall switches can control one identical lamp. This is the Tandem Switch. Please use this procedure only To achieve the purpose: Insert our In-wall Power Monitor Switch, and it when will not affect the 2 current wall switches controlling the same lamp. controller is missing or otherwise the network primary inoperable. Power ON( Z-Wave Connect) Green LED on & Red LED turn off Power Off( Z-Wave Connect) Green LED & Red LED turn off Over load Protect Red LED every 0.5 second Flash FCC Caution This device complies with Part 15 of the FCC rules standard. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM WEEE Information Controller means “Remove” or “Exclusion”. For EU (European Union) member users: According to the WEEE (Waste electrical and electronic equipment) Directive, do not dispose of this Support Z-Wave RF Package Communication FUNCTION DESCRIPTION product as household waste or commercial waste. Waste electrical and electronic equipment should be appropriately collected and recycled as Allows Association to control Combine other Slave devices required by practices established for your country. the Controller to interlock simultaneously, For information on recycling of this product, please contact your local Glossary of terms able to connect up to 5 authorities, your household waste disposal service or the shop where you Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds devices. purchased the product N - NEUTRAL wire D2 - Device 2 N - NEUTRAL wire Support Set-time for This function is to report the L - LIVE wire S1 - Switch 1 L - LIVE wire specific controller status to the controller on the set Z-Wave Plus NOTE: time. The fifth association is used This product can be included and operated in any Z-Wave network with 1. The Resistive load of single S1 or S2 is 5A at max., while the total to report to the controller after other Z-Wave certified devices from other manufacturers and/or other Resistive load of S1 plus S2 is 1150W at max., too. the node status is changed. applications. All non-battery operated nodes within the network will act as YES repeaters regardless of vendor to increase reliability of the network. 2. In the range of 1150W, you can make any permutations. However, Support Z-Wave to read when S1 is set to 1150W (the maximum of load), S2 can only be 0W, Device Detect status and and vice versa. report 2. Controller in order to fully utilize all implemented functions. Specification Basic Application Diagram 1. This device must be used in conjunction with a Security Enabled Z-Wave Connect S2 to one switch, you can control the device connected to Security S2 ITEM DESCRIPTION D2. Power Mode Self Power Connect S1 to one switch, you can control the device connected to Power Range 110 ~ 230 VAC ± 10% D1. Power Consumption Under 0.5W (Standby Mode) Frequency 868.42 MHz (EU) 916.00 MHz (US) 922.50 MHz (JP) Rated load current of AC output (resistive load) Load 2 levels of security. The Authenticated level requires the user to enter the 50/60Hz PIN code or QR code printed on the box of the in wall switch. The UnAuthenticated level does not require the PIN code. Both security levels will encrypt nearly all communication using AES-128 encryption to ensure reliable and secure communication. SmartStart Sigma Designs technology makes installation easy and secure. Simply 2 @ 5A Output circuit power of AC 2 @ 1150 W (230 VAC) output (resistive load) 2 @ 550 W (110 VAC) Power measurement accuracy P = 0 ~ 200W, +/- 2W; P > 200W, +/- 3% Load 1 Security S2 is supported with the Authenticated and UnAuthenticated install In-wall Power Monitor Switch into a wall and it will automatically attempt to join the Z-Wave network. During the inclusion process, your home automation system will ask for a PIN code or to scan a QR code. The pin code is printed on the back of In-Wall Power Monitor Switch along with the QR code. Simply enter the PIN code or scan the QR code with a compatible device. Each QR code is unique for every device. SmartStart Overload Current Protection 5A LED Indicator Red/Green * 1 communication. It is completely backwards compatible with non- Button Inclusion / Exclusion Protocol Z-Wave Plus SmartStart systems if your home automation system doesn’t support it yet. Ex: Data Rate 100 kbps Operation Range 100 feet (About 30M) Application Indoor use Operation Temperature -10℃ ~ + 40℃ User Interface (Cable) 16AWG * 6 Housing PC+ABS Dimensions (L*W*H) 45.5 x 44.8 x 20.3 mm uses the latest Security S2 encryption technology for all radio WARNING: Important safety instructions. It is important for the safety of persons to follow these instructions. Save these instructions. - Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury - All wiring interconnecting with this controller is non-isolated hazardous live parts. - The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. - Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. - Do not use if repair or adjustment is necessary. - Do not allow children to play with fixed controls. Keep remote controls away from children. - The drive shall be disconnected from its power source during cleaning, maintenance and when replacing parts. - Indoor use only. - Never install independent switch for each S1 and S2, to prevent the activation on D1 and D2 at the same time. - Material used only for the 16 AWG copper wires and the suggested strip length is 4.5 ~ 5 mm. - Equipment shall not be interconnected with the output of another power source. - High Voltage - Disconnect power supply before servicing. - Risk of Electric Shock - More than one disconnect switch may be required to de-energize the device before servicing.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : henry_chen Create Date : 2018:08:02 14:52:00+08:00 Modify Date : 2018:08:14 18:35:08+08:00 Language : zh-TW Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Producer : Microsoft® Word 2016 Format : application/pdf Creator : henry_chen Creator Tool : Microsoft® Word 2016 Metadata Date : 2018:08:14 18:35:08+08:00 Document ID : uuid:769FF832-CDDC-40D4-9C79-F89AFB4F8D53 Instance ID : uuid:f682147a-4ffb-482d-ba1f-df125b63685c Page Count : 3EXIF Metadata provided by EXIF.tools