GSH13

1½- To 5-Ton Split System Heat Pumps
13 SEER / R-22
Contents
Nomenclature........................................ 2
Product Specifications........................... 3
AHRI Ratings........................................... 4
Dimensions............................................ 5
Wiring Diagrams.................................... 6
Accessories............................................. 7

Standard Features

Cabinet Features

•	
•	
•	
•	

•	 Louver design sound control top
•	 Steel louver coil guard
•	 Heavy-gauge, galvanized-steel
cabinet with rust-resistant screws
•	 Attractive Architectural Gray powder-paint
finish with 500-hour salt-spray approval
•	 Single-panel access to controls with space
provided for field-installed accessories
•	 When properly anchored, meets the
2010 Florida Building Code unit integrity
requirements for hurricane-type winds
(Anchor bracket kits available.)

•	
•	
•	
•	
•	
•	
•	

Energy-efficient compressor
Quiet condenser fan system
Copper tube/aluminum fin coil
For use with R-22 refrigerant and
charged with inert gas for shipping
Factory-installed bi-flow liquid line filter drier
Low-pressure switch
Time-initiated, temperatureterminated defrost control
Service valves with sweat connections and easy-access gauge ports
Contactor with lug connection
Ground lug connection
ETL Listed

*	Complete warranty details available
from your local dealer or at www.
goodmanmfg.com.

SS-GSH13

www.goodmanmfg.com

11/13
Supersedes 9/13

Product Specifications

Nomenclature
G

S

H

13

036

1

A

A

1

2

3

4,5

6,7,8

9

10

11

Brand
G
Goodman® (Standard
Feature Set Models)

Engineering *
Minor Revision
Engineering *
Major Revision

Product Category
S
Split System
Unit Type
C
Condenser R-22
H
Heat Pump R-22

1
018
024
030
036

Efficiency
13 13 SEER

Electrical
208/230 V, 1 Phase, 60 Hz
1½ Tons
2 Tons
2½ Tons
3 Tons

Nominal Capacity
042 3½ Tons
048 4 Tons
060 5 Tons

* Neither used for order entry
or inventory management.

2

www.goodmanmfg.com

SS-GSH13

Product Specifications

Specifications
GSH13
0181C*

GSH13
0241C*

GSH13
0301C*

GSH13
0361C*

GSH13
0421B*

GSH13
0481B*

GSH13
0601A*

Tonnage

1½

2

2½

3

3½

4

5

Decibels

73

71

72

71

76

76

77

RLA

8.3

10.8

13.5

14.1

19.2

19.9

25.0

LRA

40.3

56.0

68.0

75.0

112.0

104.0

148.0

Type

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Horsepower

1/8

1/8

1/8

¼

¼

¼

1/6

FLA

0.7

0.7

0.7

1.5

1.5

1.5

1.1

Liquid Line Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

Suction Line Size (“O.D.)

¾"

¾"

¾"

⅞"

1⅛"

1⅛"

1⅛"

Liquid Valve Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

Suction Valve Size (“O.D.)

¾"

¾"

¾"

⅞"

⅞"

⅞"

⅞"

Sweat

Sweat

Sweat

Sweat

Sweat

Sweat

Sweat

127

122

130

188

246

208

233

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

11.1

14.2

17.6

19.1

25.5

26.4

32.3

Capacities and Ratings

Compressor

Condenser Fan Motor

Refrigerant System
Refrigerant Line Size

Refrigerant Connection Size

Valve Type
Refrigerant Charge
Electrical Data
Voltage-Phase (60 Hz)
Minimum Circuit Ampacity ²
Max. Overcurrent Protection ³

15

25

30

30

40

45

50

Min / Max Volts

197/253

197/253

197/253

197/253

197/253

197/253

197/253

Electrical Conduit Size

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

Equipment Weight (lbs)

142

147

146

146

152

152

278

Ship Weight (lbs)

159

164

164

164

170

170

300

¹ Tested and rated in accordance with AHRI Standard 210/240
² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
•	 Always check the S&R plate for electrical data on the unit being installed.
•	 Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
•	 Charge to be added for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
•	 Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.

SS-GSH13

www.goodmanmfg.com

3

Product Specifications

AHRI Ratings
Outdoor
Unit

Indoor
Unit

Cooling Capacity¹
Total

Sens.

SEER²

EER³

TVA Ratings⁴
Total

Sens.

Heating Capacity¹
High

HSPF⁵

Low

CFM

AHRI #

GSH130484A*

AR*F486016B*

45,000 33,800

13.0

11.0

41,500 31,800 43,000

8.2

27,000 1,600 1492572

GSH130601A*

AR*F486016B*

55,500 41,000

13.0

11.0

51,500 37,000 55,500

8.5

35,000 1,800 1492576

GSH130603A*

AR*F486016B*

55,500 41,000

13.0

11.0

51,500 37,000 55,500

8.5

35,000 1,800 1492581

GSH130604A*

AR*F486016B*

55,500 41,000

13.0

11.0

51,500 37,000 55,500

8.5

35,000 1,800 1492585

GSH130241(B,C)*

AR*F182416B*+TXV

23,000 17,800

13.0

11.0

21,400 15,800 21,400

7.7

11,800

GSH130301(B,C)*

AR*F363616B*

27,800 20,200

13.0

11.0

25,800 19,300 25,400

7.7

15,300 1,020 4692016

GSH130181(B,C)*

AR*F182416B*

17,600 13,100

13.0

11.0

16,300 11,800 16,800

7.7

8,900

GSH130361(B,C)*

AR*F374316B*

33,600 26,200

13.0

11.0

31,000 23,400 31,400

7.7

18,200 1,260 4692017

GSH130604AC

AR*F486016B*

55,500 41,500

13.0

11.0

51,500 37,000 55,500

8.5

35,000 1,800 4982919

GSH130481B*

AR*F486016B*

45,000 33,800

13.0

11.0

41,500 31,800 43,000

8.2

27,000 1,600 5528480

GSH130421B*

AR*F364216B*

40,000 29,800

13.0

11.0

37,200 28,200 39,000

8.0

23,000 1,250 5528479

GSH130363A*

AR*F374316B*

33,600 26,200

13.0

11.0

31,000 23,400 31,400

7.7

18,200 1,260 5528484

GSH130483B*

AR*F486016B*

45,000 33,800

13.0

11.0

41,500 31,800 43,000

8.2

27,000 1,600 5528481

GSH130484AD

AR*F486016B*

45,000 33,200

13.0

11.0

41,500 31,800 43,000

8.2

27,000 1,600 5528482

860
625

4675037
4675036

¹ BTU/h
² Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F
⁴ TVA Rating: BTU/h @ 75°F/ 63°F - 95°F
⁵ HSPF = Heating Seasonal Performance Factor
Notes
•	 Always check the S&R plate for electrical data on the unit being installed.
•	 When matching outdoor unit to indoor unit, use the piston supplied with outdoor unit or that specified on the piston kit chart supplied with the indoor unit.
•	 EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay

4

www.goodmanmfg.com

SS-GSH13

Product Specifications

Dimensions
W
D

H

Model

SS-GSH13

www.goodmanmfg.com

Dimensions
W”

D”

H”

GSH130181C

26

26

32¼

GSH130241C

26

26

32¼

GSH130301C

29

29

34¾

GSH130361C

29

29

38¼

GSH130421B

29

29

32¼

GSH130481B

29

29

34¾

GSH130601A

35½

35½

34¾

5

6

L2

L1

www.goodmanmfg.com

IO

CM

AUX

MAIN

ALTERNATE
DOUBLE POLE
CONTACTOR

T2

T1

YL

2

1

BK SR

5

BK

BK

RD

R R

RD

YL

RD

WH

W2

C

PU

R

AUX

MAIN

COMP

RD

DFT

H
V
D
R

S

DF1

DF2

BK

YL

RD
RD

BK

BK

Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.

BK

O O

OR

BR

BL

YL

PU

BL

C Y

LVDR

DC

LPS

DFT

RVC

BK

BK

YL

RD

H
C

CH
(IF USED)
SEE NOTE 3

CHS

RD

BL

YL

GR

O
Y
C

OR
YL
BL
L1
C

T1

R

R

IO

LVDR

DFT

CHS

X
AU

SR

S

O

O

CH

MA
IN

X
AU

LPS

Y

DC

(IF USED)
NOTE 3

DFT

W2

2

CM

IO

COMP
M
AIN
R

DF2

HVDR

DF1

C

5

C

F

H

1

C

C

RVC

(IF USED)

SA

RCCF

SC

OUTDOOR POWER SUPPLY
SEE RATING PLATE

T2
C

L2

CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.

⚡

0140R00019P-B

COMPONENT CODE
R
C
C --------------- CONTACTOR
Y
W2
O
CH ------------- CRANKCASE HEATER
CHS ------------- CRANKCASE HEATER SWITCH
INDOOR POWER
CM ------------ OUTDOOR FAN MOTOR
SUPPLY
COMP -------- COMPRESSOR
DC ------------- DEFROST CONTROL
NOTES:
DFT ----------- DEFROST THERMOSTAT
1. TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR
THERMOSTAT.
HVDR -------- HIGH VOLTAGE DEFROST RELAY
2. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.
IO -------------- INTERNAL OVERLOAD
3. CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE
LPS ------------ LOW PRESSURE SWITCH
FACTORY INSTALLED OPTION.
LVDR --------- LOW VOLTAGE DEFROST RELAY
4. USE COPPER CONDUCTOR ONLY.
LVJB ---------- LOW VOLTAGE JUNCTION BOX
USE N.E.C. CLASS 2 WIRE
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
RVC ----------- REVERSING VALVE COIL
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)

FIELD WIRING
HIGH VOLTAGE

WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE

NOTE 1

LVJB

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

BK

EQUIPMENT GROUND
SEE NOTE 4

F

RCCF

RD

RD

SA
(IF USED)
NOTE 2
RD

RD

BR

PU

C

RD

RD

Warning

RD

L2

T2

RD

BK

YL

YL

T1
L1

⚠

BK

YL

YL

BL

BK BK
BL BK BK

SC

W2

WH

COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW

R

RD

ALTERNATE DOUBLE
POLE CONTACTOR ONLY

CONTROL BOX

Product Specifications

Wiring Diagram

SS-GSH13

Product Specifications

Accessories
Model

Description

GSH13
018

GSH13
024

GSH13
030

GSH13
036

GSH13
042

GSH13
048

GSH13
060

ABK-20

Anchor Bracket Kit *

X

X

X

X

X

X

X

ASC01

Anti-Short Cycle Kit

X

X

X

X

X

X

X

CSR-U-1

Hard-start Kit

X

X

X

X

X

X

CSR-U-2

Hard-start Kit

CSR-U-3

Hard-start Kit

FSK01A¹

Freeze Protection Kit

X

X

X

X

X

X

X

OT/EHR18-60

Emergency Heat Relay kit

X

X

X

X

X

X

X

OT18-60A²

Outdoor Thermostat with Lockout Stat

X

X

X

X

X

X

X

*
	
¹	
²	
³	

X

Contains 20 brackets; four brackets needed to anchor unit to pad
Installed on indoor coil
Required for heat pump applications where ambient temperatures fall below 0 °F with 50% or higher relative humidity.
Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor
coil using a non-bleed thermal expansion valve refrigerant metering device. The TXV should always be sized based on the tonnage of the outdoor unit.

SS-GSH13

www.goodmanmfg.com

7

Product Specifications

Notes

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2013 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.

8

www.goodmanmfg.com

SS-GSH13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Create Date                     : 2013:09:27 11:56:24-05:00
Modify Date                     : 2013:11:22 10:49:20-06:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Metadata Date                   : 2013:11:22 10:49:20-06:00
Format                          : application/pdf
Document ID                     : uuid:6a60ddfe-4dad-5e47-affa-26e553f61b5e
Instance ID                     : uuid:fabb7121-0a50-5b41-bea5-f0c62e948c7f
Page Count                      : 8
EXIF Metadata provided by EXIF.tools

Navigation menu