ARUF Multi-Position, Three-Speed Air Handler with Galvanized Cabinet 1½ to 5 Tons Standard Features • Suitable for use with the refrigerants R-410A and R-22 • All-aluminum evaporator coil • Check flowrater expansion device for cooling-only and heat pump applications • Direct-drive, multi-speed motor • Transformer and blower time-delay on all units • AHRI Certified; ETL Listed Cabinet Features • • • • Rust-resistant, fully insulated steel cabinet Galvanized, leather grain-embossed finish Attractive Architectural Gray painted front panels Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections • Built-in filter rack for 1” filter (filter not included) • Power supply entry at top; low-voltage entry on left side and top Contents Nomenclature .................................................................... 2 Product Specifications ....................................................... 3 Dimensions ........................................................................ 4 Airflow Data ....................................................................... 5 Heat Kit Match-Ups . .......................................................... 6 Wiring Diagram . ................................................................ 7 Accessories ......................................................................... 8 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-GARUF www.goodmanmfg.com 2/12 Supersedes 2/11 Product Specifications Nomenclature A 1 R 2 Brand A Single-piece Air Handler Unit Application C Ceiling Mount PSC Motor D Downflow PSC Motor E Multi-Position Variable-Speed Motor R Multi-Position PSC Motor S Multi-Position EEM Motor W Wall Mount PSC Motor Cabinet Finish U Unpainted P Painted N Uncased Expansion Device F Flowrater T Expansion Valve U 3 F 4 3642 5,6,7,8 1 9 6 10 AA 11,12 Engineering * Major/ Minor Revisions * Not used for inventory management Refrigerant Charge No Digit = R-22 only 6 = R-410A or R-22 Electrical 1 208/240 V, 1 Phase, 60 Hz Nominal Capacity Range @ 13 SEER Multi-Position & Downflow Applications 1729 1½ to 2½ Tons (for Export Systems) 1830 1½-3½ Tons 3642 3-3½ Tons Ceiling Mount & Wall Mount Applications (Nominal Cooling Capacity/ Electric Heat kW) 1805 1½ Tons Cooling/ 5 kW Electric Heat 2405 2 Tons Cooling/ 5 kW Electric Heat 3608 3 Tons Cooling/ 8 kW Electric Heat 2 www.goodmanmfg.com SS-GARUF Product Specifications Specifications ARUF 172916* ARUF 182416* ARUF 193116* ARUF 303016* ARUF 363616* Cooling (Btu/h) 18,000 - 30,000 18,000 - 24,000 18,000 - 30,000 30,000 36,000 Airflow Rate CFM (High/ Med/ Low)* 1,025/ 860/ 650 1,025/ 860/ 650 1,025/ 780/ 545 1,240/ 1,230/ 980 1,155/ 1,140/ 955 9½" 9½" 9½" 9½" 9½" Nominal Ratings Blower Diameter Width 6" 6" 6" 8" 8" Coil Drain Connect FPT ¾" ¾" ¾" ¾" ¾" Liquid ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" 208 - 230 208 - 230 208 - 230 208 - 230 208 - 230 2.4/ 2.4 2.4/ 2.4 1.9/ 1.9 3.3/ 3.3 3.3/ 3.3 Refrigerant Line Connection Size Electrical Data Voltage Min Circuit Ampacity Max. Overcurrent Device (amps) 15/ 15 15/ 15 15/ 15 15/ 15 15/ 15 197/ 253 197/ 253 197/ 253 197/ 253 197/ 253 1.9/ ⅓ 1.9/ ⅓ 1.48/ ¼ 2.64/ ⅓ 2.64/ ⅓ 110 116 155 144 164 ARUF 364216* ARUF 374316* ARUF 486016* ARUF 496116* 36,000 - 42,000 36,000 - 42,000 48,000 - 60,000 48,000 - 60,000 1,625 / 1,400/ 1,250 1,925/ 1,550/ 1,345 2,070/ 1,905/ 1,590 2,040/ 1,895/ 1,585 10⅝" 11 15/16" 10⅝" 10⅝" Width 8" 10⅝" 10⅝" 10⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" Liquid ⅜" ⅜" ⅜" ⅜" Suction ⅞" ⅞" ⅞" ⅞" 208 - 230 208 - 230 208 - 230 208 - 230 3.7 /3.9 4.2/ 4.2 5.1/ 5.1 5.1/ 5.1 Min. / Max VAC Blower Motor FLA/ HP Ship Weight (lbs) *CFM @.3 static Nominal Ratings Cooling (Btu/h) Airflow Rate CFM (High/ Med/ Low)* Blower Diameter Refrigerant Line Connection Size Electrical Data Voltage Min Circuit Ampacity Max. Overcurrent Device (amps) 15/ 15 15/ 15 15/ 15 15/ 15 Min. / Max VAC 197/ 253 197/ 253 197/ 253 197/ 253 Blower Motor FLA/ HP 3.12/ ½ 3.39/ ½ 4.06/ ¾ 4.06/ ¾ 160 195 183 192 Ship Weight (lbs) *CFM @.3 static SS-GARUF www.goodmanmfg.com 3 Product Specifications Dimensions Model A B C D E F G H I J ARUF172916* 42⅛” 22” 13½” 15½” 10” 14½” 11¹⁵/₁₆” 13⅛” 17¹⁵/₁₆” 2” ARUF182416* 42⅛” 22” 13½” 15½” 10” 14½” 11¹⁵/₁₆” 13⅛” 17¹⁵/₁₆” 2” ARUF193116* 46¾” 22” 17½” 19½” 10” 14½” 11¹⁵/₁₆” 17⅛” 17¹⁵/₁₆” 2” ARUF303016* 46¾” 22” 17½” 19½” 10” 14½” 11¹⁵/₁₆” 17⅛” 17¹⁵/₁₆” 2” ARUF363616* 46¾” 22” 17½” 19½” 10” 14½” 11¹⁵/₁₆” 17⅛” 17¹⁵/₁₆” 14/5” ARUF364216* 53¼” 24” 20” 22” 12” 14½” 11¹⁵/₁₆” 19⅝ 19¹⁵/₁₆” 14/5” ARUF374316* 53¼” 24” 20” 22” 12” 14½” 11¹⁵/₁₆” 19⅝ 19¹⁵/₁₆” 14/5” ARUF486016* 53¼” 24” 20” 22” 12” 14½” 11¹⁵/₁₆” 19⅝ 19¹⁵/₁₆” 14/5” ARUF496116* 53¼” 24” 20” 22” 12” 14½” 11¹⁵/₁₆” 19⅝ 19¹⁵/₁₆” 14/5” ARUF496116* 53¼” 24” 20” 22” 12” 14½” 11¹⁵/₁₆” 19⅝ 19¹⁵/₁₆” 14/5” 4 www.goodmanmfg.com SS-GARUF Product Specifications Airlfow Data Model ARUF172916* ARUF182416* ARUF193116* ARUF303016* ARUF363616* ARUF364216* ARUF374316* ARUF486016* ARUF496116* CFM Delivered Against External Static Pressure Motor Speed 0.1” 0.2” 0.3” 0.4” 0.5” High 1,155 1,090 1,025 950 895 Med 940 890 860 815 755 Low 695 665 650 610 550 High 1,155 1,090 1,025 950 895 Med 940 890 860 815 755 Low 695 665 650 610 550 High 1,135 1,085 1,025 965 915 Med 860 825 780 750 680 Low 600 570 545 500 465 High 1,385 1,315 1,240 1,155 1,065 Med 1,340 1,290 1,230 1,140 1,050 Low 1,075 1,030 980 910 840 High 1,310 1,240 1,155 1,090 1,020 Med 1,270 1,210 1,140 1,075 980 Low 1,045 1,005 955 885 805 High 1,700 1,660 1,625 1,545 1,505 Med 1,500 1,440 1,400 1,350 1,345 Low 1,300 1,300 1,250 1,230 1,220 High 2,065 2,000 1,925 1,860 1,780 Med 1,685 1,635 1,550 1,470 1,410 Low 1,490 1,425 1,345 1,280 1,205 High 2,150 2,120 2,070 2,000 1,940 Med 1,940 1,930 1,905 1,860 1,790 Low 1,610 1,600 1,590 1,575 1,550 High 2,150 2,105 2,040 1,970 1,880 Med 1,960 1,935 1,895 1,825 1,750 Low 1,670 1,625 1,585 1,525 1,455 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V / 240V SS-GARUF www.goodmanmfg.com 5 Product Specifications Heat Kit Applications HKR-03* HKR-05*, HKR-05C* HKR-06* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKR-15C* HKR-20C* HKR-21C* ^ HKR3-15* ^ HKR3-20* ARUF 172916* ARUF 182416* ARUF 193116* ARUF 303016* ARUF 363616* ARUF 364216* ARUF 374316* ARUF 486016* ARUF 496116* X X X X¹ X¹ X² X X X X¹ X¹ X² X X X X¹ X¹ X² X X X X X¹ X² X² X² X² X² X X X X X X2 X X X X X X³ X³ X³ X³ X³ X X X X X X³ X³ X³ X³ X³ X X X X X X X X X X X X X X X X X X X X * Revision level that may or may not be designated C Circuit breaker option ^ Heat kit requires three-phase power supply X2 ¹ Air handler must either be on medium or high speed ² Air handler must be on high speed ³ Air handler must be on medium or high speed Single-Point Kit ** Model SPW-01 HKR-15C HKR-20C HKR-21C X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any ARUF air handler as long as a compatible heat kit is installed in the unit. 6 www.goodmanmfg.com SS-GARUF Product Specifications ARUF Wiring Diagram Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ SS-GARUF www.goodmanmfg.com 7 Product Specifications Accessories Expansion Valve Kits for Air Conditioning and Heat Pump Applications Kit Number Description Application Refrigerant Tonnage: Outdoor Unit XVB18-36C 20% Bleed Valve AC Only R-22 1½ - 3 Ton XVB42-60C 20% Bleed Valve AC Only R-22 3½ - 5 Ton XV18-36C Non-bleed Valve AC Only R-22 1½ - 3 Ton XV42-60C Non-bleed Valve AC Only R-22 3½ - 5 Ton TX2N2 Non-bleed Valve AC or HP R-22 1½ - 2 Ton TX3N2 Non-bleed Valve AC or HP R-22 2½ - 3 Ton TX5N2 Non-bleed Valve AC or HP R-22 3½ - 5 Ton TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton Drain Pan Insulation Kit for Downflow Applications Chassis Size Insulation Kit Small (15½”) DPI18-30/20 Medium (19½”) DPI36-42/20 Large (22”) DPI48-60/20 Note: Each kit contains enough material to modify 20 coils Filters Model Filter # Qty Required 1729/ 1824 FIL 18-32 1 1931 FIL-36-42 1 3030/ 3636 FIL-36-42 1 3642/ 3743 FIL 48-61 1 4860/4961 FIL 48-61 1 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2012 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 8 www.goodmanmfg.com SS-GARUF
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Create Date : 2012:02:20 08:31:07-06:00 Modify Date : 2012:03:21 12:14:43-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Metadata Date : 2012:03:21 12:14:43-05:00 Format : application/pdf Document ID : uuid:32dd8258-038f-484a-8d6d-bc0573569d59 Instance ID : uuid:d23a0d62-0b3a-e448-9728-82628eddacbd Page Count : 8EXIF Metadata provided by EXIF.tools