Gorko Systems G1 5VDC POWERED WIRELESS TO INTERNET GATEWAY User Manual

Gorko Systems Inc. 5VDC POWERED WIRELESS TO INTERNET GATEWAY

USERS MANUAL

(((MiWSN)))Wireless Sensors NetworkMi-Sensor-1 and Mi-Gateway-1User Manual
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc1/14ContentsCertifications (FCC and IC) ____________________________________________________ 11 Mi-Sensor-1 ______________________________________________________________ 21.1 Sensor Introduction ______________________________________________________ 21.2 Battery Installation ______________________________________________________ 21.3 Sensor Installation _______________________________________________________ 21.4 Sensor Notifications______________________________________________________ 31.5 Sensor Precautions ______________________________________________________ 32 Mi-Gateway-1 ____________________________________________________________ 42.1 Gateway Introduction ____________________________________________________ 42.2 Gateway Installation _____________________________________________________ 42.3 Gateway Reset __________________________________________________________ 42.4 Gateway Repeater Function _______________________________________________ 42.5 Gateway Web Management Interface ________________________________________ 52.6 Gateway Login Authentication _____________________________________________ 52.7 Setup Page _____________________________________________________________ 62.8 Rebooting Page _________________________________________________________ 82.9 Configure Page _________________________________________________________ 82.10 Configuring Page_______________________________________________________ 102.11 Status Page ____________________________________________________________ 112.12 Help Page _____________________________________________________________ 12Warranty Information ________________________________________________________ 13Limitation of Warranty and Remedies. ___________________________________________ 13Certifications (FCC and IC)Contains Mi-Sensor-1 FCC ID: AUF-S1 and Mi-Gateway-1 FCC ID: AUF-G1This device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions: (1) this device may not cause harmful interference and (2) this device must acceptany interference received, including interference that may cause undesired operation.Contains Mi-Sensor-1 IC: 10170A-S1 and Mi-Gateway-1 IC: 10170A-G1This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subjectto the following two conditions: (1) this device may not cause interference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of thedevice.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc2/141 Mi-Sensor-11.1  Sensor IntroductionThe Mi-Sensor-1 is a multifunction battery powered wireless sensor thatis capable of simultaneously monitoring Temperature, Motion, andMoisture present or Contact closure1.2 Battery InstallationOpen sensor by prying case open by hand.  InsertCR2032 battery in holder ensuring to observepolarity indicator on battery and battery holder.WARNING – Incorrect installation willdamage sensor and void warranty.1.3 Sensor InstallationConfigure sensor using gateway CONFIGURE page.  See gateway sensor configuring section fordetails.Test sensor signal strength at the location the sensor is intended to be use by pressing the testbutton on the sensor and viewing the sensor message signal strength (RSSI) on the gatewaySTATUS page.  If signal strength is too low or the gateway is unable to receive the sensor testmessage, try adjusting the sensor and gateway orientation, and location.For temperature and motion sensing, the sensor only needs to be placed in a suitable location.If the sensor is being use to sense the presence of a liquid or contactclosure, attach the supplied sensing wire to the sensor moisture/contactterminal block.  Each of the two wires of one end is inserted into thetwo larger terminal block holes.  You may use your own supplied 18-24 AWG wire if the supplied wire is not suitable for your application.To release the wire from the terminal block, insert a pin into the twosmaller slots of the terminal block.For moisture sensing, the other ends of the wire should be spaced about 3mm (1/8 inch) apartand placed in a location they can come in contact with the liquid.For contact sensing, the other ends of the wire should be attached to a dry contact closureelement such as a door open/close contact containing a reed switch.Attach double sided tape to sensor and attach sensor in final sensinglocation.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc3/141.4  Sensor NotificationsThe sensors will send notifications to the email account specified in the gateway Setup page.Notifications consist of alarm conditions or periodic reports as defined in the Configure Page ofthe gateway and configured into the sensor.  Notifications are delivered as emails or phone textswith the subject line fields separated by comas and formatted as follows:Field Description1 Indicates the message is from a MiWSN1 network.2 Indicates the message type.  Types are;Test – the test button on the sensor was pressed.Alarm – an alarm notification condition exists with Motion, Cntct, Bat, or TempReport – send periodically if configured.Reset – the sensor battery was inserted, or a battery is very low.3 The gateway name plus the sensor name plus an event number signifying where themessage came from.  The event number is incremented each time the sensor sends amessage.4Motion = indicates Yes there is motion or No motion.5Cntct = indicates Yes if there is moisture or contacts are closed and No if the contactsare dry or open.6Bat = indicates if the battery is OK or Low. A low battery should be replaced.7Temp = indicates the current temperature. C indicates Celsius and F indicatesFahrenheit.8RSSI= indicates the signal strength of the message received by the gateway.  Thefarther away from the gateway the sensor gets, the low the signal strength will be.Signal strength is measured in dBm units.1.5 Sensor PrecautionsDo not place the sensor in liquid.Do not expose the sensor to heat in excess of 85 degrees Celsius,Do not drop the sensor to a hard surface.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc4/142 Mi-Gateway-12.1 Gateway IntroductionThe Mi-Gateway-1 receives wireless messages from multiple Mi-Sensor-1 and sends them to an email account or text phone usingyour Local Area Network (LAN) to Internet connection.  The Mi-Gateway-1 has a build in web server that you connect to with abrowser to configure all parameters of the Mi-Gateway-1 and Mi-Sensor-1.  The Mi-Gateway-1 plugs into your LAN and is poweredfrom an AC outlet.2.2 Gateway InstallationConnect gateway to your router or local area network using supplied CAT-5 cable.  If required, aCAT-5 cable up to 30m (100 feet) maybe used.  Your network should have a DHCP serverconnected to it in order for the gateway to get its initial IP address.Connect the gateway to an AC outlet using the supplied AC/DC adapter.  The green link LED onthe gateway should turn on.  You should see periodic pulses on the orange activity LED.Place the gateway in a location that provides best reception of thesensors.  The gateway has the best reception when attached to avertical surface using the provided adhesive pads.  Other orientationswill work, but be less sensitive to sensor messages.Access the gateway management interface using your web browser to configure the gateway andsensors.2.3 Gateway ResetIf you need to set the gateway parameters to the original factory settings perform the followingsteps. All previously stored gateway settings are lost.  The sensors will retain their configuredsettings.a) Remove power from the gateway.b) Press the Reset button.c) Applying power to the gateway.d) Hold the Reset button for 5 seconds.e) Release the Reset button.2.4 Gateway Repeater FunctionThe gateway may be used as a repeater to extend the range of the gateway that is connected tothe local area network (LAN).  When in this mode the gateway does not need to be connected toLAN and can be placed in any location that power is available.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc5/142.5 Gateway Web Management InterfaceThe gateway management interface may beaccessed using your web browser.  Type the nameof the gateway in your web browser address bar.The default name of the gateway is http://wsng.If your network does not support name resolution, you can type the IP address of the gatewayinto your browser.  You may find this address in your DHCP server’s active client list.After successful login to the gateway you will be presented with the Setup Page.2.6 Gateway Login AuthenticationBy default the gateway does not require you to provide alogin name and password.  If you have enabled loginauthentication you will be presented with a loginauthentication dialog similar to the following.  Enter theUser ID and User Password parameters specified in theSETUP page.  If you forget your User ID and Password,you may Reset the gateway to default settings.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc6/142.7 Setup PageThis page has one time setup parameters needed to specify the local IP network, RF network, andSMTP email. Enter and test the parameters, and press the Save button.  The setup parameters aredescribed in the following paragraphs.User ID and User Password - provides secure access to gateway web interface. Leave blank forno authentication.MAC Address - the 6-byte hex MAC address of the gateway. Each gateway must have a uniqueMAC address on the IP network.Host Name - the name of the gateway. You enter this in the web browser to access the webinterface. This is the network name reported in Emails. The default is WSNG.RF Channel - the network operates on. Valid channels are 0 to 15. Channel 0 is 2405 MHz andChannel 15 is 2480 MHz.  Channel spacing is 5 MHz.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc7/14RF Key - a 2 byte hex key used to encrypt RF messages. Only messages encrypted with thecorrect key will be processed.RF Repeat - this will enable the gateway message repeater function.  When this is set to “Yes”the gateway will retransmit valid sensor messages.  This retransmission allows the gateway to beused as a repeater to extend the range of sensor transmissions.  When acting as a repeater thegateway does not need to be plugged into a LAN.Temp Units - specifies Fahrenheit or Celsius temperature units.IP Type - the gateway can use Static or Dynamic IP addressing to join the local network. Ifdynamic addressing is used, the gateway gets then next 5 parameters from the local DHCPserver. If static addressing is used, the user specifies the next 5 parameters.IP Address - of the gateway.Subnet Mask - of the gateway.Gateway - IP address the gateway uses for external access.Primary DNS - IP address gateway uses to resolve Internet names.Secondary DNS - IP address gateway uses to resolve Internet names.Enable Emails - Enable sending Emails for messages reported by sensors.SMTP Server - Name of the outgoing Email server.SMTP Port - port number.Use SSL - encrypt email use SSL.SMTP Account - name for authentication.SMTP Password - for authentication.Notify Email Address – to send messages to. Messages are formatted in the subject line of theEmail.  Multiple email addresses separated by a coma may be used.Save-Reboot – selecting this button will save all Setup parameters and reboot gateway if needed.Test Email – selecting this button will send a test email to the Notify Email Address to verifyEmail parameters are setup correctly.  A success or fail message will be displayed after the sendis complete.  This can be as quick as less than a second, to about 60 seconds if incorrectparameters are set.  The received email subject will indicate it is from the MiWSN network,indicate it is a “TestEmail”, and indicate which gateway it came from.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc8/142.8 Rebooting PageWhen parameters are changed that affect the network operation, the gateway will automaticallyreboot and the web browser will present the Setup Page after successful boot.  If wrong networkparameters were saved and the gateway does not respond, you can reset to factory defaults byholding down the button on the gateway for 5 seconds when turning power on.2.9 Configure PageThis page is used to enter parameters needed for the operation of a sensor. The sensor will holdthese parameters. Sensor defaults will be loaded by holding the sensor test button for 5 secondswhen the gateway in not on the Configuring page. The defaults are to do no monitoring andreport nothing (power savings when not in use). The Configure parameters are described in thefollowing paragraphs.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc9/14Sensor Name - to identify the sensor messages displayed on the Status page and in Emailmessages.Motion Alarm - the sensor has an accelerometer that indicates Yes when motion is present andNo when no motion is present. The sensor can send an alarm on detecting Yes, No, or Ignoreeither.Motion Threshold - The sensitivity to motion. 1=most sensitive, 99=least sensitive.Moisture/Contact Alarm - the sensor has Moisture/Contact input that indicates Yes whencontacts have moisture across them or are shorted and No when the contacts are open. A lengthof wire can be attached to the contacts to bring the end points close to the moisture to monitor.The sensor must not get wet.Battery Alarm - occurs when the sensor battery needs replacing.Temp High Alarm - occurs when the sensor temperature becomes greater than the specifiedtemperature in degrees. Leave blank to ignore. Range is -30C to +60C.Temp Low Alarm - occurs when the sensor temperature becomes less than the specifiedtemperature in degrees. Leave blank to ignore. Range is -30C to +60C.Report Period - the sensor will send a periodic report every N minutes. Enter 0 to disablereports. A non-calibrated clock is used.Configure – selecting this button will place the gateway in the Configuring mode. When in thismode, sensors can be configured with the above parameters by holding the sensor test button for5 seconds.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc10/142.10 Configuring PageThis page allows sensors to be configured with the Configure parameters. Sensors should beclose to the gateway when performing this operation.Selecting the OK button will cancel the Configuring mode and take the user to the STATUSscreen were if a sensor is correctly configured a Config Report Type will be displayed for theconfigured sensor.  If you do not see a Config Report Type, the sensor test button was not heldfor greater than 5 seconds, or the sensor is out of range.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc11/142.11 Status PageThis page displays most recent messages reported by sensors. The Status parameters aredescribed in the following paragraphs.Name - of the sensor.Report Time - in Days:Hours:Minutes:Seconds since the sensor sent the message.Report Type - of message sent by the sensor. Config is sent after successful sensor configure,Test is sent when the sensor test button is pressed quickly, Reset is sent on very low battery orreplacement, Alarm is sent when an alarm condition is detected, and Report is sent every Nminutes if the Report Period is not zero. Test, Reset, Alarm, and Report messages will cause anEmail to be sent to the Notify Email Address.Motion - state of Motion sensor. No or Yes.Temp - current sensor temperature in units specified in the Setup page.Moisture/Contact - state of sensor Moisture/Contact input. Yes for wet/shorted and No fordry/open.Battery - state of sensor battery condition. OK or Low.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc12/14RSSI - Received Signal Strength Indicator measurement in dBm from the message sent by thesensor. This is an indication of signal quality with, -7 is the best and -91 is the weakest.Refresh – selecting this button refreshes the messages displayed.Clear – selecting this button deletes all status messages.2.12 Help PageThe gateway has a basic help page built in to aid the user when the User Manual is not handy.
MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc13/14Warranty Information(a) Gorko warrants that Gorko-branded products will be free from defects in materials and workmanship for a periodof one (1) year from the date of delivery with respect to hardware and will materially conform to their publishedspecifications for a period of one (1) year with respect to software. Gorko does not warrant that the software or anyportion thereof is error free. Gorko will have no warranty obligation with respect to Products subjected to abuse,misuse, negligence or accident. If any hardware component of any Product fails to conform to the warranty in thisSection, Gorko shall, at its option, refund the purchase price less any discounts, or repair or replace nonconformingProducts with conforming Products or Products having substantially identical form, fit, and function and deliver therepaired or replacement Product to a carrier for land shipment to customer within a reasonable period after Gorkoreceives from Customer (i) notice of such non-conformance, and (ii) the non-conforming Product provided;however, if, in its opinion, Gorko cannot repair or replace on commercially reasonable terms it may choose to refundthe purchase price. Repair parts and replacement products may be reconditioned or new. All replacement productsand parts become the property of Gorko. Repaired or replacement products shall be subject to the warranty, if anyremains, originally applicable to the product repaired or replaced. Customer must obtain from Gorko a ReturnMaterial Authorization Number (RMA) prior to returning any Products to Gorko. Products returned under thisWarranty must be unmodified. Customer may return all Products for repair or replacement due to defects in originalmaterials and workmanship if Gorko is notified within ninety (90) days of customer’s receipt of the product. Gorkoreserves the right to repair or replace products at its own and complete discretion. Customer must obtain from Gorkoa Return Material Authorization Number (RMA) prior to returning any products to Gorko. Products returned underthis Warranty must be unmodified and in original packaging. Gorko reserves the right to refuse warranty repairs orreplacements for any products that are damaged or not in original form. For products outside the ninety-daywarranty period repair services are available at Gorko at standard labor rates for a period of one year from theCustomer’s original date of receipt.(b) As a condition to Gorko’s obligations under the immediately preceding paragraphs,Customer shall return Products to be examined and replaced to Gorko’s facilities, inshipping cartons which clearly display a valid RMA number provided by Gorko. Customer acknowledges thatreplacement products may be repaired, refurbished or tested and found to be complying. Customer shall bear the riskof loss for such return shipment and shall bear all shipping costs. Gorko shall deliver replacements for Productsdetermined by Gorko to be properly returned, shall bear the risk of loss and such costs of shipment of repairedproducts or replacements, and shall credit Customer’s reasonable costs of shipping such returned Products againstfuture purchases.(c) Gorko’s sole obligation under the warranty described or set forth here shall be to repair or replace non-conforming products as set forth in the immediately preceding paragraph, or to refund the documented purchaseprice for non-conforming Products to Customer. Gorko’s warranty obligations shall run solely to Customer, andGorko shall have no obligation to customers of Customer or other users of the Products.Limitation of Warranty and Remedies.THE WARRANTY SET FORTH HEREIN IS THE ONLY WARRANTY APPLICABLE TO PRODUCTSPURCHASED BY CUSTOMER. ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUTNOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR APARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. GORKO’S LIABIITY WHETHER INCONTRACT, IN TORT, UNDER ANY WARRANTY, IN NEGLIGENCE OR OTHERWISE SHALL NOTEXCEED THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT.  UNDER NOCIRCUMSTANCES SHALL GORKO BE LIABLE FOR SPECIAL, INDIRECT OR CONSEQUENTIALDAMAGES. THE PRICE STATED FOR THE PRODUCTS IS A CONSIDERATION IN LIMITING GORKO’SLIABILITY. NO ACTION, REGARDLESS OF FORM, ARISING OUT OF THIS AGREEMENT MAY BEBROUGHT BY CUSTOMER MORE THAN ONE YEAR AFTER THE CAUSE OF ACTION HAS ACCRUED.IN ADDITION TO THE WARRANTIES DISCLAIMED ABOVE, GORKO SPECIFICALLY DISCLAIMS ANYAND ALL LIABILITY AND WARRANTIES, IMPLIED OR EXPRESSED, FOR USES REQUIRING FAIL-SAFE PERFORMANCE IN WHICH FAILURE OF A PRODUCT COULD LEAD TO DEATH, SERIOUSPERSONAL INJURY, OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE SUCH AS, BUT NOTLIMITED TO, LIFE SUPPORT OR MEDICAL DEVICES OR NUCLEAR APPLICATIONS. PRODUCTS ARENOT DESIGNED FOR AND SHOULD NOT BE USED IN ANY OF THESE APPLICATIONS.

Navigation menu