Operation Internal Chop System Low Emission Internal-Mix Gel-Coat For use with Polyester Resin, and Gel-Coat Maximum fluid working pressure by Fluid Section Assembly: 20864-05 - 1300 psi. (9 MPa, 90 bar) 21780-01 - 1700 psi. (12 MPa, 117 bar) 22026-01 - 2000 psi. (14 MPa, 138 bar) Maximum air pressure: 100 psi. (0.7 MPa, 7 bar) Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. GC-1412D Contents Warnings Warnings ............................................................................................................................................................ Important Safety Information ............................................................................................................................. Grounding .......................................................................................................................................................... 3 5 6 Set-up Set-up Instructions ............................................................................................................................................. Pressure Relief Instructions ............................................................................................................................... Start-up Instructions ........................................................................................................................................... Shut-down Instructions ....................................................................................................................................... Parts ................................................................................................................................................................... Assembly Drawings ............................................................................................................................................ Sub-Assembly Drawings .................................................................................................................................... 7 19 20 22 23 N/A 24 Maintenance Maintenance ....................................................................................................................................................... 29 Technical Data Technical Data .................................................................................................................................................. Notes ................................................................................................................................................................. Graco Ohio Standard Warranty ....................................................................................................................... Graco Ohio Information ................................................................................................................................. 30 31 32 32 N/A = Non Applicable 2 GC-1412D 9CTPKPIU The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedureVSHFL¿FULVN5HIHUEDFNWRWKHVHZDUQLQJV$GGLWLRQDOSURGXFWVSHFL¿FZDUQLQJVPD\EHIRXQGWKURXJKRXWWKH body of this manual where applicable. • See Important Safety Information - MEKP, Polyester Resins and Gel-Coats and Spraying and Lamination Operations section of this manual. 9#40+0) FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help SUHYHQW¿UHDQGH[SORVLRQ • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). .HHSZRUNDUHDIUHHRIGHEULVLQFOXGLQJVROYHQWUDJVDQGJDVROLQH 'RQRWSOXJRUXQSOXJSRZHUFRUGVRUWXUQSRZHURUOLJKWVZLWFKHVRQRURIIZKHQÀDPPDEOH fumes are present. *URXQGDOOHTXLSPHQWLQWKHZRUNDUHD6HHGrounding instructions. • Use only grounded hoses. +ROGJXQ¿UPO\WRVLGHRIJURXQGHGSDLOZKHQWULJJHULQJLQWRSDLO ,IWKHUHLVVWDWLFVSDUNLQJRU\RXIHHODVKRFNstop operation immediately. Do not use equipment until you identify and correct the problem. .HHSDZRUNLQJ¿UHH[WLQJXLVKHULQWKHZRUNDUHD • See additional information on MEKP in the MEKP Section of this manual. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, LQKDODWLRQRIWR[LFIXPHVEXUQVDQGKHDULQJORVV7KLVHTXLSPHQWLQFOXGHVEXWLVQRWOLPLWHGWR • Protective eyewear &ORWKLQJDQGUHVSLUDWRUDVUHFRPPHQGHGE\WKHÀXLGDQGVROYHQWPDQXIDFWXUHU • Gloves • Hearing protection TOXIC FLUID OR FUMES HAZARD 7R[LFÀXLGVRUIXPHVFDQFDXVHVHULRXVLQMXU\RUGHDWKLIVSODVKHGLQWKHH\HVRURQVNLQLQKDOHGRU swallowed. 5HDG06'6¶VWRNQRZWKHVSHFL¿FKD]DUGVRIWKHÀXLGV\RXDUHXVLQJ 6WRUHKD]DUGRXVÀXLGLQDSSURYHGFRQWDLQHUVDQGGLVSRVHRILWDFFRUGLQJWRDSSOLFDEOH guidelines. • Always wear impervious gloves when spraying or cleaning equipment. GC-1412D 3 Warnings 9#40+0) SKIN INJECTION HAZARD +LJKSUHVVXUHÀXLGIURPJXQKRVHOHDNVRUUXSWXUHGFRPSRQHQWVZLOOSLHUFHVNLQ7KLVPD\ORRN OLNHMXVWDFXWEXWLWLVDVHULRXVLQMXU\WKDWFDQUHVXOWLQDPSXWDWLRQGet immediate surgical treatment. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the dispense outlet. 'RQRWVWRSRUGHÀHFWOHDNVZLWK\RXUKDQGERG\JORYHRUUDJ (QJDJHWULJJHUORFNZKHQQRWVSUD\LQJ • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, FKHFNLQJRUVHUYLFLQJHTXLSPHQW MOVING PARTS HAZARD 0RYLQJSDUWVFDQSLQFKRUDPSXWDWH¿QJHUVDQGRWKHUERG\SDUWV • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. 3UHVVXUL]HGHTXLSPHQWFDQVWDUWZLWKRXWZDUQLQJ%HIRUHFKHFNLQJPRYLQJRUVHUYLFLQJ equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. 'RQRWRSHUDWHWKHXQLWZKHQIDWLJXHGRUXQGHUWKHLQÀXHQFHRIGUXJVRUDOFRKRO 'RQRWH[FHHGWKHPD[LPXPZRUNLQJSUHVVXUHRUWHPSHUDWXUHUDWLQJRIWKHORZHVWUDWHGV\VWHP component. See Technical Data in all equipment manuals. 8VHÀXLGVDQGVROYHQWVWKDWDUHFRPSDWLEOHZLWKHTXLSPHQWZHWWHGSDUWV6HHTechnical Data LQDOOHTXLSPHQWPDQXDOV5HDGÀXLGDQGVROYHQWPDQXIDFWXUHU¶VZDUQLQJV)RUFRPSOHWH information about your material, request MSDS forms from distributor or retailer. &KHFNHTXLSPHQWGDLO\5HSDLURUUHSODFHZRUQRUGDPDJHGSDUWVLPPHGLDWHO\ZLWKJHQXLQH manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. 5RXWHKRVHVDQGFDEOHVDZD\IURPWUDI¿FDUHDVVKDUSHGJHVPRYLQJSDUWVDQGKRWVXUIDFHV 'RQRWNLQNRURYHUEHQGKRVHVRUXVHKRVHVWRSXOOHTXLSPHQW .HHSFKLOGUHQDQGDQLPDOVDZD\IURPZRUNDUHD • Comply with all applicable safety regulations. PRESSURIZED ALUMINUM PARTS HAZARD 'RQRWXVHWULFKORURHWKDQHPHWK\OHQHFKORULGHRWKHUKDORJHQDWHGK\GURFDUERQVROYHQWVRUÀXLGV containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, serious injury, and property damage. 4 GC-1412D Important Safety Information Methyl Ethyl Ketone Peroxide (MEKP) MEKP is among the more hazardous materials found in commercial channels. Proper handling of the “unstable (reactive)” chemicals presents a GH¿QLWHFKDOOHQJHWRWKHSODVWLFVLQGXVWU\7KH KLJKO\UHDFWLYHSURSHUW\ZKLFKPDNHV0(.3 valuable to the plastics industry in producing the curing reaction of polyester resins and gel-coats also produces the hazards which require great care and caution in its storage, transportation, handling, processing and disposal. :RUNHUVPXVWEHWKRURXJKO\LQIRUPHGRIWKHKD]DUGV that may result from improper handling of MEKP, especially in regards to contamination and heat. They must be thoroughly instructed regarding the SURSHUDFWLRQWREHWDNHQLQWKHVWRUDJHXVHDQG disposal of MEKP and other hazardous materials used in the laminating operation. 0(.3LVÀDPPDEOHDQGSRWHQWLDOO\H[SORVLYH as well as potentially damaging to the eyes and skin. Read material manufacturer’s warnings and PDWHULDO06'6WRNQRZVSHFL¿FKD]DUGVDQG precautions related to MEKP. Contaminated MEKP can become explosive. Prevent contamination of MEKP with other materials, which includes, but is not limited to polyester overspray, polymerization accelerators and promoters, and non-stainless metals. Even small amounts RIFRQWDPLQDWHVFDQPDNH0(.3H[SORVLYH7KLVUHaction may start slowly, and gradually build-up heat, ZKLFKFDQDFFHOHUDWHXQWLO¿UHRUDQH[SORVLRQUHVXOW 7KLVSURFHVVFDQWDNHIURPVHFRQGVWRGD\V Heat applied to MEKP, or heat build-up from contamination reactions can cause it to reach what is called its Self-Accelerating Decompisition TemperaWXUH6$'7ZKLFKFDQFDXVH¿UHRUH[SORVLRQ Spills should be promptly removed, so no residues remain. Spillage can heat up to the point of selfignition. Dispose in accordance with manufacture’s recommendation. Store MEKP in a cool, dry and well-ventilated area in the original containers away from direct sunlight and away from other chemicals. It is strongly recommended that the storage temperature remain below 86° F (30° C). Heat will increase the potential for explosive decomposition. Refer to NFPA 432. .HHS0(.3DZD\IURPKHDWVSDUNVDQGRSHQ ÀDPHV GC-1412D Current catalysts are premixed and do not require any diluents. GlasCraft strongly recommends that diluents not be used. Diluants add to the possibility of contaminates entering the catalyst system. Never dilute MEKP with acetone or any solvent since this can proGXFH DQ H[WUHPHO\ VKRFNVHQVLWLYH FRPSRXQG ZKLFK can explode. Use only original equipment or equivalent parts IURP *ODV&UDIW LQ WKH FDWDO\VW V\VWHP LH KRVHV ¿Wtings, etc.) because a hazardous chemical reaction may result between substituted parts and MEKP. To prevent contact with MEKP, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons and goggles are required IRUHYHU\RQHLQWKHZRUNDUHD Polyester Resins and Gel-Coats Spraying materials containing polyester resin and gel-coats creates potentially harmful mist, vapors and atomized particulates. Prevent inhalation by providing VXI¿FLHQWYHQWLODWLRQDQGWKHXVHRIUHVSLUDWRUVLQWKH ZRUNDUHD Read the material manufacturer’s warnings and maWHULDO06'6WRNQRZVSHFL¿FKD]DUGVDQGSUHFDXWLRQV related to polyester resins and gel-coats. To prevent contact with polyester resins and gelcoats, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons and goggles are required for everyone in the ZRUNDUHD Spraying and Lamination Operations Remove all accumulations of overspray, FRP sandings, etc. from the building as they occur. If this waste LVDOORZHGWREXLOGXSVSLOODJHRIFDWDO\VWLVPRUHOLNHO\ WRVWDUWD¿UH If cleaning solvents are required, read material PDQXIDFWXUH¶VZDUQLQJVDQGPDWHULDO06'6WRNQRZ VSHFL¿FKD]DUGVDQGSUHFDXWLRQV*ODV&UDIWUHFRPPHQGVWKDWFOHDQXSVROYHQWVEHQRQÀDPPDEOH GlasCraft recommends that you consult OSHA Sections 1910.94, 1910.106, 1910.107 and NFPA No. 33, Chapter 16,17, and NFPA No. 91 for further guidance. 5 Grounding This equipment needs to be grounded. Ground the spray gun through connection to a *ODV&UDIWDSSURYHGJURXQGHGÀXLGVXSSO\KRVH &KHFN\RXUORFDOHOHFWULFDOFRGHDQGUHODWHGPDQXDOV for detailed grounding instructions of all equipment in WKHZRUNDUHD A grounding wire and clamp are provided, assembly p/n 17440-00 with all FRP equipment. Mask FilterEar The mast must be secured in the retracted position before transporting the system to prevent swinging of the mast and system imbalance. 6 GC-1412D Set-Up 6\VWHP$VVHPEO\ 2. a. Stand the pump assembly next to the mast and LQVWDOOWKHSXPSPRXQWLQJEUDFNHW $Q\PRXQWLQJRSWLRQFDUWPDVW ERRPÀRRUPRXQW or wall mount etc. should be completely assembled before starting the following steps. Tools Required: 6WDQGDUGZUHQFK VRFNHWVHW 6WDQGDUGKH[NH\VHW 3) Tape measure All “Required tools” are standard sizes. 1. Loosen clamp bolts to expose pump mounting EUDFNHW$WWDFKSXPSPRXQWLQJEUDFNHWWRWKHDLU PRWRU8VHWKUHDGORFNHURQWKHWKUHDGVDQGWLJKWHQ KH[EROWVDVWLJKWDVSRVVLEOHLQKH[NH\ HEX BOLTS E Lift to desired height with the pump assembly facing the front of the cart as shown, approximately 41in. from the top of the cart to the top of the pump mountLQJEUDFNHW8VHLQZUHQFKDQGWLJKWHQDVWLJKWDV possible. 19890-00 41in./104 cm. APPROX. GC-1412D 7 Set-Up 3. Attach air manifold p/n 23555-00 to the air motor. 5.,QVWDOOWKHFDWDO\VWMXJZLWKWKHHOERZ¿WWLQJIDFLQJWKH front of the unit. 4. 0RXQWFDWDO\VWERWWOHEUDFNHWZLWKVXSSOLHGXEROWV p/n CP-126, 34in. from the top of the cart, to the top RIWKHFDWDO\VWEUDFNHWDQGSDUDOOHOZLWKWKHPDWHULDO pump. 6. Install tubing p/n 9704-11 from the catalyst jug to the LQOHW¿WWLQJRQWKHFDWDO\VWSXPS3XVKWKHWXELQJLQWR WKHFDWDO\VWMXJVXSSO\¿WWLQJXQWLOLWVWRSV8VLQJWZR proper sized wrenches, carefully tighten the compresVLRQQXWWRORFNGRZQWKHWXELQJ The tubing must be cut to desired length, giving a natural gravity feed supply to the slave pump. 34in./86cm. APPROX. 8 GC-1412D Set-Up 7. Remove the pump inlet saftey cap and drain the testing oil into an open container. Attach green SLFNXSKRVHWRWKHSXPSLQOHW¿WWLQJDQGWLJKWHQ 8. $WWDFKJUHHQSLFNXSKRVHWRWKHSLFNXSWXEH 8. FOR INDY CHOPPER GUN INSTALLATION BEGIN STEPS 9 THROUGH 13 . FOR FORMULA CHOPPER GUN INSTALLATION BEGIN STEPS 14 THROUGH 18. 7. GC-1412D 9 Set-Up Indy Chopper Gun Option 9. a. Lay all of the hoses out straight. E ,QVWDOO¿WWLQJVSQ¶VDQG using PTFE tape on the NPT threads ONLY. c. Install the assembly from step “b” to the material hose and attach the 3 ft. whip hose p/n H42503 to the other end. 10. 6OLGHWKHVXSSOLHG³EODFNVFXIIMDFNHW´SQ)0 over the hose assembly and leave it loose until the hoses are attached to the gun. 10 GC-1412D Set-Up 11. a. Attach the hoses to the gun. Egroup the hoses together as shown and wrap them with tape about every 2 feet. c. 6WDUWDSSUR[LQEDFNIURPWKHJXQDQGWDSH WKHHQGRIWKH³EODFNVFXIIMDFNHW´ZLWKEODFN WDSH6SUHDGWKH³EODFNVFXIIMDFNHW´RXWVR LW¿WVVQXJDURXQGWKHKRVHVDQGWDSHWKH RWKHUHQGZLWKEODFNWDSH Yellow Solvent Hose p/n 236 %ODFN0DWHULDO:KLS+RVH p/n 21694-25 Red Chopper Air Hose p/n 17798-25 Stainless Steel Catalyst Hose p/n 20190-00 Fiberglass Roving Ports The B-410 chopper is shown for reference ONLY. Refer to the chopper manual for optional snouts and adjustments. GC-1412D 11 Set-Up Secure the four hoses to WKHERRPZLWKELQGLQJVWUDSV SQ See Detail C 5RXWHWKHIRXUKRVHVEHWZHHQ the two springs. Secure the four hoses to WKHERRPZLWKELQGLQJVWUDSV SQ 12. Start At This End Route the four hoses from the JXQWKURXJKWKHERRPDVVKRZQ XVLQJELQGLQJVWUDSVSQ WRVHFXUHWKHKRVHVWRWKHERRP 5RXWH¿EHUJODVVURYLQJVWUDQGV WKURXJKWKHURYLQJJXLGHV Detail C Start Fiberglass Roving Here 5RXWH¿EHUJODVVURYLQJVWUDQGV WKURXJKWKHURYLQJJXLGHV 5RXWH¿EHUJODVVURYLQJ strands through the URYLQJEUHDNJXLGHV as shown From Spool To Gun 12 GC-1412D Set-Up 13. Attach the hoses to the unit as shown. TO BOOM Clear Tubing 1/4 in. Stainless Catalyst Hose Red Air Hose Red Solvent Air Tubing Clear Tubing 1/8 in. Place decal here Clear Tubing 3/8 in. Yellow Solvent Hose %ODFN0DWHULDO+RVH GC-1412D 13 Set-Up Formula Chopper Gun Option 14. a. Lay all of the hoses and trigger air tubing out straight. E ,QVWDOO¿WWLQJVSQ¶VDQG using PTFE tape on the NPT threads ONLY. c. Install the assembly from step “B” to the material hose and attach the 3 ft. whip hose p/n H42503 to the other end. 15. 6OLGHWKHVXSSOLHG³EODFNVFXIIMDFNHW´SQ)0 over the hose assembly and leave it loose until the hoses are attached to the gun. 14 GC-1412D Set-Up Yellow Solvent Hose p/n 236 Red Chopper Air Hose p/n 17798-25 16. a. Attach the hoses to the gun. EGroup the hoses together as shown and wrap them with tape about every 2 feet. c. 6WDUWDSSUR[LQEDFNIURPWKHJXQDQGWDSH WKHHQGRIWKH³EODFNVFXIIMDFNHW´ZLWKEODFN WDSH6SUHDGWKH³EODFNVFXIIMDFNHW´RXWVR LW¿WVVQXJDURXQGWKHKRVHVDQGWDSHWKH RWKHUHQGZLWKEODFNWDSH Stainless Steel Catalyst Hose p/n 20190-00 Fiberglass Roving Ports Trigger Air Tubing p/n 9704-03 %ODFN0DWHULDO:KLS+RVH p/n 21694-25 The B-410 chopper is shown for reference ONLY. Refer to the chopper manual for optional snouts and adjustments. GC-1412D 15 Set-Up 6HFXUHWKH¿YHKRVHVWRWKH ERRPZLWKELQGLQJVWUDSV SQ See Detail C 5RXWHWKH¿YHKRVHVEHWZHHQ the two springs. 6HFXUHWKH¿YHKRVHVWRWKH ERRPZLWKELQGLQJVWUDSV SQ 17. Start At This End 5RXWHWKH¿YHKRVHVIURPWKH JXQWKURXJKWKHERRPDVVKRZQ XVLQJELQGLQJVWUDSVSQ WRVHFXUHWKHKRVHVWRWKHERRP 5RXWH¿EHUJODVVURYLQJVWUDQGV WKURXJKWKHURYLQJJXLGHV Detail C 5RXWH¿EHUJODVVURYLQJ strands through the URYLQJEUHDNJXLGHV as shown Start Fiberglass Roving Here 5RXWH¿EHUJODVVURYLQJVWUDQGV WKURXJKWKHURYLQJJXLGHV From Spool To Gun 16 GC-1412D Set-Up 18. Attach the hoses to the unit as shown. TO BOOM Clear Tubing 1/4 in. Stainless Catalyst Hose Red Air Hose Red Solvent Air Tubing Clear Tubing 1/8 in. Place decal here Trigger Air Clear Tubing Remove plug and install elbow ¿WWLQJSQ Clear Tubing 3/8 in. Yellow Solvent Hose %ODFN0DWHULDO+RVH GC-1412D 17 Set-Up SSP-175 Safety Guard Kit SSP-175 18 Part 1XPEHU Description Qty. SSP-172 SURROUND GUARD 1 SSP-173 LEFT PUMP GUARD 1 SSP-174 ANGLE BRACKET 1 SSP-176 GUARD WINDOW 1 1 SSP-177 RIGHT PUMP GUARD SSP-178 RIGHT FRONT PUMP GUARD 1 20188-16C SCREW 17 7486-05 FENDER WASHER 4 7486-13 WASHER 3 7734-06 LOCK WASHER 13 GC-1412D Pressure Relief Procedure 7RUHOLHYHÀXLGDQGDLUSUHVVXUHV 1. Push down Yellow slide valve, P/N 21402-00 to bleed off air to system. 2. Open P/N 21228-00 on catalyst pump to recirculation position. 3. Open P/N 21192-00 on bottom of material pump. GC-1412D 19 Start-Up The following assumes that all connections are tight. Before turning on main air, check all On/Off Ball Valves, making certain all Valves are in the “Off” position and set all regulators in their “Off” position. (Turn knob counterclockwise for OFF or reduced pressure setting.) System Start-Up Instructions 1. Select a clean dry air supply. 2. Attach a 3/8” or larger air hose to the Air Manifold 5. Place the mixing element straight into the front gun Inlet. 'RQRWXVHTXLFNGLVFRQQHFW¿WWLQJV housing. (refer to spray gun user manual) 6. Place the retaining nut along with the spray tip and spray tip spacer onto the gun housing. (refer to spray gun user manual) 7. Push the slide valve to the open position. 3. Attach grounding clamp assembly, P/N 17440-00, to the slave pump. 8. 2SHQWKHDLUYDOYHSQRQWKHVROYHQWWDQNDQG Attach Here adjust the solvent pressure to 90 PSI (6.2 bar). Open WKHEDOOYDOYHSQRQWKHVROYHQWWDQN1H[W open ball valve p/n 23518-00 on the gun to verify that VROYHQWZLOOÀRZRXWRIWKHIURQWRIWKHJXQWKURXJKWKH dispense tip, then close the valve. Do not exceed 20 PSI (1.4 bar)on the material UHJXODWRUXQWLODVWHDG\PDWHULDOÀRZKDVEHHQ established. Regulator 4. Securely attach Clamp, P/N 7749-00, to permanently grounded rod or pipe. Valve 18470-00 Ball valve 3165 Attach Here 13193-00 7750-04 7749-00 9654-00 TO SLAVE PUMP 20 GC-1412D Start-Up SSP-160-01 9a. Pull and rotate Pivot NQREWRGLVHQJDJHWKHFDWDO\VW drive arm. E Once primed, increase the resin PSI until a desired spray pattern is achieved. c. After all pressure adjustments have been completed, a ¿QDOVSUD\WHVWVKRXOGEHPDGH6SUD\DWHVWVKRW sample on a clean piece of paper. The shot should be DSSUR[LPDWHO\¿YHIHHWLQOHQJWK
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-702 Startup Profile : Print Producer : Acrobat Distiller 7.0.5 (Windows) Keywords : ; Internal Chop System; GC-1412; 20864-05; 21780-01; 22026-01 Create Date : 2009:04:06 11:16:53-04:00 Modify Date : 2009:04:09 13:19:10-05:00 Metadata Date : 2009:04:09 13:19:10-05:00 Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 7782 bytes, use -b option to extract) Document ID : uuid:3A71D981BD22DE119DACC7A27782B371 Instance ID : uuid:14be702f-eb9d-43bc-b31b-2c75a317b3e9 Derived From Document Name : b4cc44f5-c4c8-11da-81c7-f2703b5e136f Derived From Instance ID : uuid:31f02364-1be7-43a8-bc3f-ebda6d5f694b Derived From Document ID : adobe:docid:indd:90a1ca3d-6968-11dd-86eb-946c4298435d Derived From Rendition Class : proof:pdf Marked : True Format : application/pdf Title : GC-1412D Internal Chop System Operation Creator : Ryan Stellmaker Description : Internal Chop System, GC-1412, 20864-05, 21780-01, 22026-01 Subject : Internal Chop System, GC-1412, 20864-05, 21780-01, 22026-01 Page Count : 32 Author : Ryan StellmakerEXIF Metadata provided by EXIF.tools