Instructions–Parts List
Spring-Operated and Air-Operated, High Pressure
Mastic Fluid Regulators
307517T
ENG
5000 psi (34.4 MPa, 344 bar) Maximum
Inbound Fluid Pressure
These regulators control downstream pressure for
mastic or semi-solid material. Install a regulator ahead of
each spray gun or extruder gun in a multiple outlet
system. The regulator provides precise pressure control
to each spray gun from a common header system. It
also dampens flow surges when line valves are opened
and during pump stroke changeover.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for List of Models and Table of Contents.
TI0345
TI1371
Model 244740
Model 903958
Model 243700
Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . . . .
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Ambient Models
Part
No.
Series
Regulator
Operation
Regulated Fluid
Pressure
Maximum Inbound
Air Pressure
Parts
Page
903958
Series B
Spring-operated,
1000–4500 psi (7.0–31.0
MPa, 70–310 bar)
high range (low
range spring is available, see page 33)
961635
Series C
Air-operated
250–4500 psi (2.8–31.0
MPa, 17–310 bar)
100 psi (0.7 MPa, 7 bar)
12
244740
Series A
Air–operated
250–4500 psi (2.8–31.0
MPa, 17–310 bar)
100 psi (0.7 MPa, 7 bar)
14
C58318
Series A
Air-operated
250–4500 psi (2.8–31.0
MPa, 17–310 bar)
100 psi (0.7 MPa, 7 bar)
16
246642
Series A
Air–operated
100–4500 psi (0.7–31.0
MPa, 7–310 bar)
100 psi (0.7 MPa, 7 bar)
22
246687
Series A
Air–operated
100–4500 psi (0.7–31.0
MPa, 7–310 bar)
100 psi (0.7 MPa, 7 bar)
24
262549
Series A
Air–operated
100–2600 psi (0.7–18.0
MPa, 7–180 bar)
60 psi (0.4 MPa, 4 bar)
24
12
List of Temperature Conditioned/Heated
Models
Part
No.
Heat
Method
Regulator
Operation
Regulated Fluid
Pressure
Maximum Inbound
Air Pressure
243700
240 VAC
Air-operated
250–3500 psi (1.7–24.1
MPa, 17–241 bar)
65 psi (0.45 MPa, 4.5 bar)
10
C07720
Ambient
Air-operated
250–3500 psi (1.7–24.1
MPa, 17–241 bar)
65 psi (0.45 MPa, 4.5 bar)
18
918447
120 VAC
Air–operated
(Mounting Bracket
Kit Available)
250–3500 psi (1.7–24.1
MPa, 17–241 bar)
65 psi (0.45 MPa, 4.5 bar)
20
246643
240 VAC
Air-operated
100–3500 psi (0.7–24.1
MPa, 7–241 bar)
65 psi (0.45 MPa, 4.5 bar)
26
246688
240 VAC
Air-operated
100–3500 psi (0.7–24.1
MPa, 7–241 bar)
65 psi (0.45 MPa, 4.5 bar)
28
2
307517
Parts
Page
31
32
33
34
34
Symbols
Warning Symbol
Caution Symbol
WARNING
CAUTION
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
corresponding instructions.
WARNING
SKIN INJECTION HAZARD
Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an
extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin
can also cause a serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment.
D Do not point the spray gun/dispensing valve at anyone or at any part of the body.
D Do not put hand or fingers over the spray tip/nozzle.
D Do not stop or deflect fluid leaks with your hand, body, glove, or rag.
D Do not “blow back” fluid; this is not an air spray system.
D Always have the tip guard and the trigger guard on the spray gun/dispensing valve when spraying/
dispensing.
D Be sure the gun trigger safety operates before spraying.
D Lock the gun/valve trigger safety when you stop spraying.
D Follow the Pressure Relief Procedure in your separate equipment manuals whenever you: are
instructed to relieve pressure; stop spraying; clean, check, or service the equipment; and install or
clean the spray tip.
D Tighten all the fluid connections before operating the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.
Warnings are continued on the next page.
307517
3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and
result in fire or explosion and serious injury.
D Ground all equipment in the work area. See Grounding in your separate system manual.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being
sprayed.
D Extinguish all the open flames or pilot lights in the spray/dispensing area.
D Electrically disconnect all the equipment in the spray/dispensing area.
D Keep the spray/dispensing area free of debris, including solvent, rags, and gasoline.
D Do not turn on or off any light switch in the spray/dispensing area while operating or if fumes are
present.
D Do not smoke in the spray/dispensing area.
D Do not operate a gasoline engine in the spray/dispensing area.
D If there is any static sparking while using the equipment, stop spraying/dispensing immediately.
Identify and correct the problem.
D Keep a fire extinguisher in the work area.
TOXIC FLUID HAZARD
Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the
skin, swallowed, or inhaled.
D Know the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.
D Store hazardous fluid in an approved container. Dispose of the hazardous fluid according to all
local, state, and national guidelines.
D Wear appropriate protective clothing, gloves, eyewear, and respirator.
Warnings are continued on the next page.
4
307517
WARNING
EQUIPMENT MISUSE HAZARD
INSTRUCTIONS
Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result
in a serious injury.
D This equipment is for professional use only.
D Read all the instruction manuals, tags, and labels before operating the equipment.
D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D Check the equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated system component. This equipment has a 5000 psi (34.4 MPa, 344 bar) maximum inbound fluid pressure.
D Use fluids that are compatible with the equipment wetted parts. See the Technical Data section of
all the equipment manuals. Read the fluid manufacturer’s warnings.
D Route the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not
expose Graco hoses to temperatures above 180_F (82_C) or below –40_F (–40_C).
D Do not kink or over bend the hoses or use the hoses to pull equipment.
D Wear hearing protection when operating this equipment.
D Comply with all applicable local, state, and national fire, electrical, and other safety regulations.
D If your spray or extruder gun has a lower pressure rating than the pump, be sure you adjust its fluid
regulator low enough to avoid exceeding the gun’s maximum working pressure.
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate fingers.
D Do not operate the equipment with the air motor plates removed.
D Keep clear of any moving parts when starting or operating the equipment.
HOT SURFACE AND FLUID HAZARD
Heated fluid can cause severe burns and can cause equipment surfaces to become very hot.
D Wear protective gloves and clothing when operating this equipment in a heated system.
D Do not touch the metal heat sink when the surface is hot.
D Allow the equipment to cool thoroughly before servicing.
Some heated systems are designed to dispense Polyurethane (PUR) heated materials. PUR systems
are supplied with ventilation hoods, and require proper ventilation and specially designed system
components.
307517
5
Installation
Air Regulator
Air Supply
Fluid Regulator
Fluid Shutoff Valve
Wall Bracket
Fluid from Pump
Check Valve
Applicator
Typical Installation (Air–Operated Fluid Regulator Shown)
General Information
NOTES:
D Reference numbers and letters in parentheses in
the text refer to the callouts in the figures and the
parts drawing.
D The Typical Installation shows a typical dead-end
hookup. Regulators should be mounted close to the
dispense point. The whip hose and nozzle must
provide enough back pressure to stay within the
adjustable range of the regulator. The majority of
this restriction should be provided by the nozzle, to
prevent static head pressure from increasing when
the valve closes.
The regulators have one 3/4 npt(f) inlet port and two
3/4 npt(f) outlet ports for straight through or right angle
flow. Install one regulator upstream from each gun on
the line. A fluid pressure gauge can be installed in the
second outlet port for precise monitoring of outlet
pressure. Plug the port when not in use. See the
Typical Installation, above, and the Dimensions
section on page 30.
6
307517
WARNING
When the second outlet port is not used, it must be
plugged with a steel plug, supplied, to prevent high
pressure fluid from being emitted from the port.
High pressure fluid can cause serious injury.
For an air-operated regulator, connect a grounded air
supply hose to the 1/4 npt(m) adapter at the inlet of the
air regulator.
Conversion Kit Installation
1. To relieve fluid pressure, shut off the power to the
pump, trigger the gun to relieve pressure, and
open any system bleed or drain valves. Remove
the regulator from the line.
2. If installing a new spring, unscrew and remove the
adjusting screw (6) and spring (9). Install the new
spring and reinstall the screw.
3. If converting to an air-operated regulator, unscrew
and remove the adjusting screw (6), spring (9),
and spring guide (11) from the valve cylinder (7).
Apply lubricant to the threads of the conversion kit
diaphragm housing (101). Screw the housing into
the valve cylinder, torque to 20 in-lb (2.25 NSm).
See the Parts Drawing on page 12.
Operation
Adjusting the Regulator Outlet Pressure
WARNING
To reduce the risk of serious injury, never remove
the adjusting screw or diaphragm housing when the
valve is under pressure.
NOTE: Model 244740 is equipped with inlet and outlet
pressure sensor ports. Pressure Sensor Kit 198082
can be used to monitor inlet and/or outlet pressures.
This chart shows the approximate air pressure needed
to regulate the air-operated regulator to a given fluid
outlet pressure.
For a spring-operated regulator, turn the adjusting
screw (6) counterclockwise to decrease and clockwise
to increase pressure to the spray gun or extruder gun.
For an air-operated regulator, adjust the air regulator
on top of the diaphragm (or other upstream air regulation device), to adjust the downstream fluid pressure
up or down. See the chart at right for air vs. fluid
pressure.
Adjust the pump air pressure and the mastic regulator
pressure for the best dispensing combination. For the
optimum performance, the inbound fluid pressure
should be at least 600 psi (4.1 MPa, 41 bar) above the
regulated fluid pressure.
NOTE: When using a fluid pressure gauge in the
regulator outlet, partially relieve pressure by triggering
the gun while reducing the regulator pressure. This
helps ensure a correct gauge reading. For high accuracy applications, add a C06234 bleed fitting. This adjustable flow control replaces an outlet plug in the
regulator. This allows the air regulator to hold a more
accurate set point. Model C58318 comes with this
bleed valve.
Air Pressure
Regulated Fluid Outlet
Pressure
psi
bar
kPa
psi
bar
MPa
10
0.7
70
500
35
3.5
15
1.0
100
800
55
5.5
20
1.4
140
1100
76
7.6
25
1.7
170
1300
90
9.0
30
2.1
210
1600
110
11.0
40
2.8
280
2100
145
14.5
50
3.5
350
2700
186
18.6
60
4.2
420
3200
221
22.1
70
4.9
490
3800
262
26.2
80
5.6
560
4300
296
29.6
307517
7
Maintenance
WARNING
To reduce the risk of serious injury, including fluid
injection, or splashing in the eyes or on the skin,
always relieve the air and fluid pressure in the
system before adjusting, repairing, or removing the
regulator from the system.
Flushing
4. Open the fluid regulator fully.
a. Spring Operated Regulators Only. Open the
fluid regulator by turning the adjusting screw
(6) fully clockwise.
b. Air Operated Regulator Only. Increase the air
regulator setting to fully open the fluid regulator. You will have to reset the fluid regulator’s
pressure setting after flushing.
D Flush before changing colors, before fluid can dry in
the equipment, at the end of the day, before storing,
and before repairing equipment.
5. Supply solvent to the system. Set pump to the
lowest possible pressure, and start pump.
D Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
7. Adjust the fluid regulator to the desired setting.
D Flush with a fluid that is compatible with the fluid
being dispensed and the equipment wetted parts.
1. Record the pressure adjustment setting of the fluid
regulator before flushing.
6. Flush until thoroughly clean.
a. Spring Operated Regulators Only: Turn the
adjustment screw (6) counterclockwise to
return to the desired pressure setting.
b. Air Operated Regulator Only. Adjust the air
regulator to return to the desired fluid pressure
setting.
2. Shut off the pump and relieve fluid pressure in the
system by triggering the gun and opening the back
pressure regulator or other bypass valve.
Repair
3. Never exceed the maximum working pressure of
the lowest rated system component. Remove the
gauge if the flushing pressure will exceed the
gauge range.
Disassemble the regulator. See the Parts Drawing on
page 10. You do not have to disassemble the diaphragm housing of the air-operated regulator unless a
problem is suspected.
8
307517
Flush the regulator if possible, relieve fluid pressure,
and remove the regulator from the system.
Notes
307517
9
Parts
Model 243700 240 Volt Heated Regulator
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (11)
5
Torque to 170–190 in–lb (19–21 NSm)
29
5
32
28
39
38
in alternating pattern.
111
31
26
Ref. No. 9 Conversion Kit 915587
105
30
35
44
115
21
107
103
23
24, 25
106
15
108
104
*4
6
8
114
102
*4
113
*13
12
4
1
14
5
*11
3
101
3
10
7
2
2
16
1
20
TI0342
10
307517
Parts
Model 243700 230 Volt Heated Regulator
Diaphragm Housing / Conversion Kit 915587
Includes items 101–115
Ref
No.
Part No.
Description
1
2
3
4*
5
6
7
8
9
607499
607498
904029
115938
904030
617434
607497
607500
915587
10
11*
12*
13*
14
15
16
220899
102386
115939
607495
607718
607496
503143
20
21
23
24
25
26
28
29
30
31
32
33
102726
100171
115861
115860
115862
C19269
C19197
C19800
C34043
C34040
C19721
C32255
34
198600
35
065345
38
101674
39
112144
44
102974
CAP, end
BAR, support bottom
BALL, seat
PACKING, o-ring; fluoroelastomer
SEAT, regulator
HOUSING, regulator
SUPPORT, piston
CYLINDER, valve
HOUSING, diaphragm
(See separate parts list)
PISTON, regulator
RING, retaining
SEAL, mastic reg. fluoroelastomer
WASHER
WASHER, seal
SPACER
SCREW, socket head;
5/16–18 x 2.75 in.
PLUG, pipe, 3/4 in. npt
SCREW, machine pnh
BULKHEAD, housing
INSERT, male
CONNECTOR, male
SCREW, machine, slotted
WASHER, plain
SCREW, cap, socket hd
BRACKET
COVER
WASHER
SENSOR, temperature
See page 31 electrical diagram
CARTRIDGE, heater
See page 31 electrical diagram
WIRE, copper electrical (16AWG);
0.5 ft (0.15 m)
See page 31 electrical diagram
TERMINAL, ring
See page 31 electrical diagram
SCREW, mach pan hd
See page 31 electrical diagram
NUT, hex
Qty.
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
2
1
2
1
1
5
2
2
2
1
1
1
Ref
No.
Part No.
Description
101
102
103
104
105
15U747
180978
15U746
180979
108190
106
107
100403
110341
108
111
103656
120730
113
114
115
180975
103263
151519
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
1
REGULATOR, air, relieving;
see manual 308167
1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
Qty.
* Included in Repair Kit 233131.
1
2
1
1
1
2
307517
11
Parts
Model 903958, Series B
Spring-Operated Regulator
Includes items 1–21
Model 961635, Series C
Air-Operated Regulator
Includes items 1–5, 7, 8, 13–22
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (3)
5
Torque to 170–190 in–lb (19–21 NSm)
Ref. No. 22 Conversion Kit 915587
Regulator 961635 only
in alternating pattern.
111
5
115
105
107
18
103
8*
106
108
13
104
Ref. No. 6, 9, 11
Regulator 903958 only
114
7
6
8*
102
1
9
4
113
*5
*19
*3
20
1
21
17
11
3
15
2
101
2
16
14
OR
OR
4
7241B
12
307517
Parts
Model 903958, Series B
Spring-Operated Regulator
Includes items 1–21
Model 961635, Series C
Air-Operated Regulator
Includes items 1–5, 7, 8, 13–22
Ref
No.
Part No.
Description
1
2
607718
503143
3*
4
5*
6
102386
102726
503140
607501
WASHER, seal
SCREW, socket head;
5/16–18 x 2.75 in.
RING, retaining
PLUG, pipe, 3/4 in. npt
SEAL, mastic reg., urethane
SCREW, adjusting;
Model 903958 only
CYLINDER, valve
PACKING, o-ring; buna-N
SPRING, high range;
Model 903958 only
GUIDE, spring;
Model 903958 only
HOUSING, regulator
CAP, end
PISTON, regulator
BAR, support top
BAR, support bottom
SPACER
WASHER
SEAT, regulator;
0.312 in. (8 mm) dia.
BALL, seat
HOUSING, diaphragm;
Model 961635 only
(See separate parts list)
7
8*
9†
607500
162841
503141
11
607493
13
14
15
16
17
18
19*
20
607502
607499
220899
607497
607498
607496
607495
904030
21
22
904029
915587
Diaphragm Housing / Conversion Kit 915587
Includes items 101–115
Qty.
1
2
1
1
1
1
1
2
Ref
No.
101
102
103
104
105
Part No.
15U747
180978
15U746
180979
108190
106
107
100403
110341
108
111
103656
120730
113
114
115
180975
103263
151519
1
1
1
1
1
1
1
2
1
Description
Qty.
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
1
REGULATOR, air, relieving;
see manual 308167
1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
* Included in Repair Kit 918448.
† 521079 Low Range Spring is available. See page 33.
1
1
1
307517
13
Parts
Model 244740, Series A
Air-Operated Regulator
Includes items 1–37
1
Torque to 30–40 ft-lb (41–54 NSm)
2
Torque to 75–80 in-lb (8.5–9 NSm)
3
Torque to 170–190 in–lb (19–21 NSm)
13*
in alternating pattern.
4
4
12*
Lips must face retaining ring (11)
34
11*
29
3
10
27
7
28
15
32
2
36*
26
6
31
36*
14
9
5
1
3
8
2
16
1
22
TI1463A
14
307517
Parts
Model 244740, Series A
Air-Operated Regulator
Includes items 1–37
Ref
No.
1
2
3
5
Part No.
607499
607498
904029
904030
6
7
8
9
10
11*
12*
13*
14
15
198007
607497
607500
15U747
220899
102386
607495
503140
607718
607496
Description
CAP, end
BAR, support bottom
BALL, seat
SEAT, regulator;
0.312 in. (8 mm) dia.
HOUSING, regulator
BAR, support top
CYLINDER, valve
HOUSING, diaphragm
PISTON, regulator
RING, retaining
WASHER
SEAL, mastic reg., urethane
WASHER, seal
SPACER
Qty.
1
1
1
1
1
1
1
1
1
1
1
1
1
2
Ref
No.
16
Part No.
503143
22
26
27
28
29
102726
180978
15U746
180979
120730
31
32
34
35
180975
103263
198171
198241
36*
37
162841
111457
Description
Qty.
SCREW, socket head;
5/16–18 x 2.75 in.
2
PLUG, pipe, 3/4 in. npt
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
CAPSCREW, hex washer head;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, machine; 1/4–20 x 3/4 in. 1
ELBOW
1
PLUG, port, pressure
(not shown)
4
PACKING, o–ring
2
PACKING, o–ring, pressure port
(not shown)
4
* Included in Repair Kit 918448.
307517
15
Parts
Model C58318
Stainless Steel, Air Operated Regulator
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (16)
5
Torque to 170–190 in–lb (19–21 NSm)
Ref. No. 3 Conversion Kit 915587
in alternating pattern.
111
5
115
105
107
11
103
14
108
4
13
104
20
114
14
102
12
4
113
3
18
17
16
19
21
101
15
10
1
9
8
7
2
6
1
7241B
16
307517
Parts
Diaphragm Housing / Conversion Kit 915587
Includes items 101–115
Model C58318
Stainless Steel, Air Operated Regulator
Ref
No.
Part No.
Description
1
3
111384
915587
4
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
C06234
607499
C55143
C55136
C55140
C55139
C55137
C55133
C55134
C38296
C55135
C20385
C58314
515716
C55141
C58312
C55142
PLUG, pipe
HOUSING, diaphragm
(See separate parts list)
VALVE, flow control
CAP, end
SCREW, cap, socket head
SUPPORT, piston, bottom
STEM, valve assy
SEAT, regulator, assy
SPACER
WASHER, seal
HOUSING, regulator
PACKING, o-ring
SUPPORT, piston, top
RING, retaining, internal
SUPPORT, seal
PACKING, u-cup
PISTON, regulator
CYLINDER, regulator
PIN, str, spring
Qty.
1
1
1
1
2
1
1
1
2
1
1
2
1
1
1
1
1
1
1
Ref
No.
Part No.
Description
101
102
103
104
105
15U747
180978
15U746
180979
108190
106
100403
107
110341
108
111
103656
120730
113
114
115
180975
103263
151519
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
(not shown)
1
REGULATOR, air, relieving;
see manual 308167
1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
Qty.
307517
17
Parts
Model C07720 Water Conditioned Regulator
Includes items 1–20
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (11)
5
Torque to 170–190 in–lb (19–21 NSm)
Ref. No. 9 Conversion Kit 915587
in alternating pattern.
111
5
115
105
107
106
103
15
4*
108
104
6
8
114
4*
102
4
14
*13
12*
113
*11
5
1
3
2
3
101
10
16
2
7
1
20
TI0344
18
307517
Parts
Model C07720 Water Conditioned Regulator
Includes items 1–20
Ref
No.
Part No.
Description
1
2
3
4*
5
6
7
8
9
607499
607498
904029
162841
904030
C07719
607497
607500
915587
CAP, end
BAR, support bottom
BALL, seat
PACKING, o-ring; buna-N
SEAT, regulator
HOUSING, regulator
SUPPORT, piston
CYLINDER, valve
HOUSING, diaphragm
(See separate parts list)
PISTON, regulator
RING, retaining
WASHER
SEAL, mastic reg., urethane
WASHER, seal
SPACER
SCREW, socket head;
5/16–18 x 2.75 in.
PLUG, pipe, 3/4 in. npt
10
11*
12*
13*
14
15
16
220899
102386
607495
503140
607718
607496
503143
20
102726
Diaphragm Housing / Conversion Kit 915587
Includes items 101–115
Qty.
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
2
1
Ref
No.
Part No.
Description
101
102
103
104
105
15U747
180978
15U746
180979
108190
106
107
100403
110341
108
111
103656
120730
113
114
115
180975
103263
151519
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
1
REGULATOR, air, relieving;
see manual 308167
1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
Qty.
* Included in Repair Kit 918448.
307517
19
Parts
Model 918447 Heated Regulator
Mounting Bracket Kit 247157
Available for Model 918447 only.
Purchase separately.
See page 33.
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (11)
5
Torque to 170–190 in–lb (19–21 NSm)
31
26
29
28
in alternating pattern.
27
32
Ref. No. 9 Conversion Kit 915587
30
24
111
105
5
115
23
107
103
15
106
*4
108
104
6
8
114
102
113
*12
13*
*4
14
4
1
5
*11
3
101
3
10
7
2
2
16
1
20
TI0560
20
307517
Parts
Model 918447 Heated Regulator
Ref
No.
Part No.
Description
1
2
3
4*
5
6
7
8
9
607499
607498
904029
115938
904030
617434
607497
607500
915587
Ref
No.
Part No.
Description
101
102
103
104
105
15U747
180978
15U746
180979
108190
10
11*
12*
13*
1
14
15
16
20
23
24
25
26
27
28
29
30
31
32
33
220899
102386
607495
115939
CAP, end
1
BAR, support
1
BALL, seat
1
PACKING, o–ring
2
SEAT, regulator
1
HOUSING, heated, regulator
1
SUPPORT, piston
1
CYLINDER, valve
1
HOUSING, diaphragm
(See separate parts list)
1
PISTON, regulator
1
RING, retaining
1
WASHER
1
SEAL, rod, .750 ID, fluoroelastomer
106
107
100403
110341
108
111
103656
120730
113
114
115
180975
103263
151519
34
C31034
WASHER, seal
SPACER
SCREW, cap, sch
PLUG, pipe, headless
CONNECTOR, 6–pin gun
SCREW, cap, sch
NUT, hex
SCREW, mach, slotted hd
TERMINAL, ring
WASHER, plain
SCREW, cap, socket hd
BRACKET
COVER
WASHER
SENSOR, temperature
See page 31 electrical diagram
HEATER, cartridge
See page 31 electrical diagram
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
1
REGULATOR, air, relieving;
see manual 308167
1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
607718
607496
503143
102726
C07329
C19950
102794
C19269
C50019
C19197
C19800
C34043
C34040
C19721
C32255
Qty.
1
2
2
1
1
4
4
2
1
2
2
1
1
1
Diaphragm Housing / Conversion Kit 915587
Includes items 101–115
Qty.
* Included in Repair Kit 233131.
1
2
307517
21
Parts
Model 246642, Series A
Air-Operated Regulator
Includes items 1–37
34
29
3
1
Torque to 30–40 ft-lb (41–54 NSm)
2
3
Torque to 75–80 in-lb (8.5–9 NSm)
Torque to 170–190 in-lb (19–21 NSm) in an
alternating pattern.
4
Lips must face retaining ring (11)
13*
4
27
12*
11*
28
10
32
26
2
7
15
36*
31
6
9
36†*
14
8
5
1
3
2
16
22†
1†
22
307517
Parts
Model 246642, Series A
Air-Operated Regulator
Includes items 1–37
Ref
No.
1†
2
3
5
Part No.
15C280
607498
904029
904030
6
7
8
9
10
11*
12*
13*
14
15
198007
607497
607500
15U747
220899
102386
607495
503140
607718
607496
Description
CAP, end
BAR, support bottom
BALL, seat
SEAT, regulator;
0.312 in. (8 mm) dia.
HOUSING, regulator
BAR, support top
CYLINDER, valve
HOUSING, diaphragm
PISTON, regulator
RING, retaining
WASHER
SEAL, mastic reg., urethane
WASHER, seal
SPACER
Qty.
1
1
1
1
1
1
1
1
1
1
1
1
1
2
Ref
No.
16
Part No.
503143
22†
26
27
28
29
15C281
180978
15U746
180979
120730
31
32
34
35
180975
103263
198171
198241
36†*
37
162841
111457
Description
Qty.
SCREW, socket head;
5/16–18 x 2.75 in.
2
SPRING, compression
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
CAPSCREW, hex washer head;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, machine; 1/4–20 x 3/4 in. 1
ELBOW
1
PLUG, port, pressure
(not shown)
4
PACKING, o–ring
2
PACKING, o–ring, pressure port
(not shown)
4
* Included in Repair Kit 918448.
† Included in Repair Kit 246728.
307517
23
Parts
Model 246687 and 262549, Series A
Air-Operated Regulator
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (3)
5
Torque to 170–190 in–lb (19–21 NSm)
Ref. No. 22 Conversion Kit 915587
in alternating pattern.
111
105
115
107
5
18
103
8*
108
104
13
106
114
102
4
7
8*†
*5
1
20
*19
*3
113
1
21
17
3
15
101
2
16
4†
14†
7241B
24
307517
2
Parts
Model 246687 and 262549, Series A
Air-Operated Regulator
Ref
No.
Part No.
Description
1
2
607718
503143
3*
4†
5*
7
8*†
13
14†
15
16
17
18
19*
20
102386
15C281
503140
607500
162841
607502
15C280
220899
607497
607498
607496
607495
904030
21
22
904029
915587
WASHER, seal
SCREW, socket head;
5/16–18 x 2.75 in.
RING, retaining
SPRING, compression
SEAL, mastic reg., urethane
CYLINDER, valve
PACKING, o-ring; buna-N
HOUSING, regulator
CAP, end
PISTON, regulator
BAR, support top
BAR, support bottom
SPACER
WASHER
SEAT, regulator;
0.312 in. (8 mm) dia.
BALL, seat
HOUSING, diaphragm
(See parts list at right)
Diaphragm Housing / Conversion Kit 915587
Qty.
1
2
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
Ref
No.
Part No.
Description
101
102
103
104
105
15U747
180978
15U746
180979
108190
106
107
100403
110341
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
1
REGULATOR, air, relieving; model
246687 only, see manual 308167 1
REGULATOR, air, relieving; model
262549 only, see manual 308167 1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
16G409
108
111
103656
120730
113
114
115
180975
103263
151519
Qty.
* Included in Repair Kit 918448.
† Included in Repair Kit 246728.
307517
25
Parts
Model 246643, 240 Volt Heated Regulator
1
Torque to 35–40 ft-lb (47–54 NSm)
2
Use LoctiteR TL–242 on threads
3
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (11)
5
Torque to 170–190 in–lb (19–21 NSm) in alternating
pattern.
31
26
29
111
5
32
28
105
39
103
38
30
35
44
23
21
104
15
24, 25
*4
6
114
8
102
†*4
*13
113
12*
4
1
*11
3
101
14
5
3
2
10
2
16
7
†20
1†
TI0342 rev
26
307517
Parts
Model 246643, 240 Volt Heated Regulator
Ref
No.
Part No.
Description
1†
2
3
4*†
5
6
7
8
10
11*
12*
13*
14
15
16
15C280
607498
904029
115938
904030
617434
607497
607500
220899
102386
115939
607495
607718
607496
503143
20†
21
23
24
25
26
28
29
30
31
32
33
15C281
100171
115861
115860
115862
C19269
C19197
C19800
C34043
C34040
C19721
C32255
34
198600
35
065345
38
101674
39
112144
44
102974
CAP, end
BAR, support bottom
BALL, seat
PACKING, o-ring; fluoroelastomer
SEAT, regulator
HOUSING, regulator
SUPPORT, piston
CYLINDER, valve
PISTON, regulator
RING, retaining
SEAL, mastic reg. fluoroelastomer
WASHER
WASHER, seal
SPACER
SCREW, socket head;
5/16–18 x 2.75 in.
SPRING, compression
SCREW, machine pnh
BULKHEAD, housing
INSERT, male
CONNECTOR, male
SCREW, machine, slotted
WASHER, plain
SCREW, cap, socket hd
BRACKET
COVER
WASHER
SENSOR, temperature
See page 31 electrical diagram
CARTRIDGE, heater
See page 31 electrical diagram
WIRE, copper electrical (16AWG);
0.5 ft (0.15 m)
See page 31 electrical diagram
TERMINAL, ring
See page 31 electrical diagram
SCREW, mach pan hd
See page 31 electrical diagram
NUT, hex
Qty.
1
1
1
2
1
1
1
1
1
1
1
1
1
2
Ref
No.
Part No.
Description
101
102
103
104
105
111
15U747
180978
15U746
180979
198171
120730
113
114
180975
103263
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
ELBOW
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
Qty.
* Included in Repair Kit 233131.
† Included in Repair Kit 246728.
2
1
2
1
1
5
2
2
2
1
1
1
1
2
1
1
1
2
307517
27
Parts
Model 246688, 240 Volt Heated Regulator
1
Torque to 35–40 ft-lb (47–54 NSm)
3
Use LoctiteR TL–242 on threads
Use LoctiteR 601 on threads.
Torque to 15–25 ft-lb (20–34 NSm)
4
Lips must face retaining ring (11)
5
Torque to 170–190 in–lb (19–21 NSm) in alternating
pattern.
2
31
26
29
32
28
Ref. No. 9 Conversion Kit 915587
39
38
115
111
30
35
44
105
5
21
107
103
23
24, 25
106
15
108
104
*4
6
8
114
102
*13
113
12*
†*4
14
4
1
*11
3
2
101
3
5
10
7
2
16
†20
1†
TI0342B
28
307517
Parts
Model 246688, 240 Volt Heated Regulator
Diaphragm Housing / Conversion Kit 915587
Includes items 101–115
Ref
No.
Part No.
Description
1†
2
3
4*†
5
6
7
8
9
15C280
607498
904029
115938
904030
617434
607497
607500
915587
10
11*
12*
13*
14
15
16
220899
102386
115939
607495
607718
607496
503143
CAP, end
BAR, support bottom
BALL, seat
PACKING, o-ring; fluoroelastomer
SEAT, regulator
HOUSING, regulator
SUPPORT, piston
CYLINDER, valve
HOUSING, diaphragm
(See separate parts list)
PISTON, regulator
RING, retaining
SEAL, mastic reg. fluoroelastomer
WASHER
WASHER, seal
SPACER
SCREW, socket head;
5/16–18 x 2.75 in.
SPRING, compression
SCREW, machine pnh
BULKHEAD, housing
INSERT, male
CONNECTOR, male
SCREW, machine, slotted
WASHER, plain
SCREW, cap, socket hd
BRACKET
COVER
WASHER
SENSOR, temperature
See page 31 electrical diagram
CARTRIDGE, heater
See page 31 electrical diagram
WIRE, copper electrical (16AWG);
0.5 ft (0.15 m)
See page 31 electrical diagram
TERMINAL, ring
See page 31 electrical diagram
SCREW, mach pan hd
See page 31 electrical diagram
NUT, hex
20†
21
23
24
25
26
28
29
30
31
32
33
15C281
100171
115861
115860
115862
C19269
C19197
C19800
C34043
C34040
C19721
C32255
34
198600
35
065345
38
101674
39
112144
44
102974
Ref
No.
Part No.
Description
1
1
1
2
1
1
1
1
101
102
103
104
105
15U747
180978
15U746
180979
108190
106
107
100403
110341
1
1
1
1
1
1
2
108
111
103656
120730
113
114
115
180975
103263
151519
HOUSING, diaphragm
1
WASHER, support
1
COVER, diaphragm
1
DIAPHRAGM
1
GAUGE, air pressure; 0–100 psi
(0–0.7 MPa, 0–7 bar) range
1
PLUG, pipe; 1/8–27 npt(f)
1
REGULATOR, air, relieving;
see manual 308167
1
NIPPLE, pipe, hex; 1/8–27 npt
1
CAPSCREW, hex washer hd;
1/4–20 x 1.5
12
ROD, piston
1
SCREW, mach; 1/4–20 x 3/4 in. 1
NIPPLE, 1/4 x 1/8 npt
1
Qty.
2
1
2
1
1
5
2
2
2
1
1
1
Qty.
* Included in Repair Kit 233131.
† Included in Repair Kit 246728.
1
2
1
1
1
2
307517
29
Dimensions
1/4 npt(m)
AIR CONNECTION
3.25 in.
(82.5 mm)
CONVERSION
KIT 915587
6.8 in.
(173 mm)
3/4 npt(f)
OUTLET
3/4 npt(f)
SIDE INLET
13.5 in.
(343 mm)
3/4 npt(f)
OUTLET
3/4 npt(f)
INLET
12 in.
(305 mm)
10.5 in.
(267 mm)
2.75 in.
(70 mm)
2.63 in.
(67 mm)
Models 961635, C58318, 243700,
C59584, 244740, 246642, 246643, 246687,
and 246688.
30
307517
2.63 in.
(67 mm)
OPTIONAL
3/4 npt(f)
OUTLET
Model 903958 and C58318
7243B
Wiring Diagram
These regulators are controlled by Graco Therm–O–Flow controls.
120 Volt Models 918447
{33
TI0504
{ 108.2 Ω (+/– 1.1 Ω @ 70°F)
} 96 Ω (+9.6 Ω /−14.4 @ Ω each)
}34
Resistance measurements across pins C and F = 40.8 – 52.8 Ω
NOTE: Allow sufficient lead wire length to be able to rotate connector bracket +/–180°
____________________________________________________________________________________________
This regulator is controlled by Graco Therm–O–Flow Plus controls.
240 Volt Model 243700, 246643, and 246688
K34
WIRING DIAGRAM
SCHEMATIC DIAGRAM
K34
{33
38
39
35
{ 108.2 Ω (+/– 1.1 Ω @ 70°F)
TI0504
K 288 Ω (+28.8 Ω /−14.4 @ Ω each)
Resistance measurements across pins 1 and 2 = 136.8 – 158.4 Ω
307517
31
Technical Data
Category
Data
Regulated Fluid Pressure Range
Models 961635, C58318, and 244740
250–4500 psi (1.7–31.0 MPa, 17–310 bar)
Models 243700 and 918447
250–3500 psi (1.7–24.1 MPa, 17–241 bar)
Model 903958
High Range: 1000–4500 psi (7.0–31.0 MPa, 70–310 bar)
Low Range: 400–1000 psi (2.8–7.0 MPa, 28–70 bar)
Models 246642 and 246687
100–4500 psi (0.7–31.0 MPa, 7–310 bar)
Model 246643 and 246688
100–3500 psi (0.7–24.1 MPa, 7–241 bar)
Maximum Fluid Inlet Pressure
5000 psi (34.4 MPa, 344 bar)
Maximum Fluid Temperatures
Ambient or conditioned
Heated
140°F (60°C)
400°F (202°C)
Pressure Drop (Measured at 400 psi inlet
pressure and 1.5 gpm)
Viscosity of 25,000 CPS: 100 psid
Viscosity of 80,000 CPS: 375 psid
Wetted Parts 903958, 961635, 244740,
246642, and 246687
zinc-plated carbon steel, brass, stainless steel, Buna-N, urethane,
tungsten carbide
Wetted Parts 243700, 918447, 246643, and
246688
zinc-plated carbon steel, brass, stainless steel, fluoroelastomer,
tungsten carbide
Wetted Parts C58318
303, 304, 316 stainless steel, tungsten carbide, UHMWPE, ethylene propylene, PTFE
Inlet (one)
3/4 npt(f), at side
Outlets (two)
3/4 npt(f), at side and bottom, at side only on 246642, 246643,
246687, 246688, and 262549.
Weights
Air Operated Model 961635: 17.75 lb (7.9 kg)
Spring Operated Model 903958: 13.5 lb (6.1 kg)
LoctiteR is a registered trademark of the Loctite Corporation.
32
307517
Accessories
113654 Fluid Pressure Gauge
915587 Spring to Air Conversion Kit
Maximum pressure: 5000 psi (34 MPa, 340 bar).
1/4 npt(m). Requires bushing (100615).
Converts an existing 903958 spring-operated regulator
to an air-operated regulator
521079 Low Range Conversion Spring
246728 Spring Loaded Fluid Section Conversion Kit
Replaces the original spring in the 903958 regulator
when 400–1000 psi (2.8–7.0 MPa, 28–70 bar) regulated pressure range is required.
Replaces end cap 607499 with 15C280 and adds
spring 15C281. Allows for lower regulated outlet fluid
pressure. The appropriate o–ring must be used for the
correct regulator. O–rings are shipped for all regulator
assemblies. Refer to parts list for your regulator and
install the appropriate o–ring.
C06234 Bleed Valve (3/8 NPT)
Adjustable air regulator bleed for improved fluid pressure accuracy. Replaces the plug in air regulator outlet
port.
247157 Mounting Bracket Kit
Available for Model 918447 only.
307517
33
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the distributor closest to you:
Phone: 612–623–6921 or Toll Free: 1–800–328–0211 Fax: 612–378–3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 307517
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
Copyright 2001, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 10/2010
34
307517
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Keywords : 307517, Mastic Fluid Regulators Create Date : 2010:10:08 13:32:12-05:00 Creator Tool : Interleaf, Inc. Modify Date : 2010:10:13 16:17:43-05:00 Metadata Date : 2010:10:13 16:17:43-05:00 Format : application/pdf Creator : Emil Meindl Title : 307517T - Mastic Fluid Regulators, Instructions-Parts, English Description : Mastic Fluid Regulators Subject : 307517, Mastic Fluid Regulators Document ID : uuid:631d44eb-3f49-4989-9d44-8a271ba6b006 Instance ID : uuid:0bc8d6c4-91c9-4edf-a329-417ea75e2808 Page Count : 34 Author : Emil MeindlEXIF Metadata provided by EXIF.tools