Page Count: 20
Repair
Displacement Pump 310643T
EN
8016A
3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure
Model 248204, Series A
UltrarMax II and Ultimate Mx II 695 and 795
ASM Zip--Sprayt2700 Plus, 3100 Plus
ASM AllPro Mach 8600 Plus and 11000 Plus
ASM H2700 Plus
Model 255968, Series A
ASM 3600G Plus
Model 248205, Series A
Ultra Max II and Ultimate Mx II 1095 and 1595
Model 249059, Series A
TexSpraytMark V
Model 249057, Series A
TexSpray Mark V
Model 277069, Series A
LineLazertIV 3900, R300
Model 277070, Series A
LineLazertIV 5900
Model 253056, Series A
Mark IV
Model 257146, Series A
Ironman 300E and Ironman 500G
Important Safety instructions
Read all warnings and instructions in this manual.
Save these instructions.
2 310643
Table of Contents
Warnings 2......................................
Service 3.......................................
Technical Data 15................................
Parts, Pump
248204, 255968 16.............................
248205, 249057, 249059, 277070, 257146 17.....
253056 18.....................................
Warranty 20.....................................
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
DDo not exceed the maximum working pressure temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
DUse fluids and solvents compatible with equipment wetted parts. See Technical Data in all equip-
ment manuals. Read manufacturer fluid and solvent warnings.
DCheck equipment daily. Repair or replace worn or damaged parts immediately.
DDo not alter or modify equipment.
DRead all instruction manuals, tags, and labels before operating the equipment.
DUse equipment only for its intended purpose. Call your Graco distributor for information.
DDo not use 1,1,1--trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or
fluids containing such solvents in pressurized aluminum equipment. Such use could result in a
chemical reaction, with the possibility of explosion.
DComply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch or amputate your fingers.
DKeep clear of moving parts.
DDo not operate equipment with protective guards or covers removed.
DPressurized equipment can start without warning. Before checking, moving or servicing equipment,
follow the Pressure Relief Procedure on page 3. Disconnect power cord.
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks or ruptured components will pierce skin. This may look like
just cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
DDo not point the gun at anyone or at any part of the body.
DDo not put your hand over the spray tip.
DDo not stop or deflect leaks with your hand, body, glove or rag.
DDo not spray without tip guard and trigger guard installed.
DEngage the gun trigger safety when you stop spraying.
DFollow the Pressure Relief Procedure on page 3 if the spray tip clogs and before cleaning,
checking or servicing the equipment.
3310643
Service
Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT H
A
Z
A
RD
The system pressure must be manually
relieved to prevent the system from
starting or spraying accidentally. To
reduce the risk of an injury from accidental spray
from the gun, splashing fluid, or moving parts,
follow the Pressure Relief Procedure whenever
you:
Dareinstructedtorelievethepressure,
Dstop spraying,
Dcheck or service any of the system equipment,
Dor install or clean the spray nozzle.
1. Engage gun safety latch.
2. Turn ON/OFF switch to OFF.
3. Unplug power cord.
4. Disengage gun safety latch. Hold metal part of gun
against grounded metal pail and trigger gun into
pail to relieve pressure.
5. Engage gun safety latch.
6. Open any fluid drain valves in system. Leave drain
valve open until ready to dispense again.
Pump Repair Kits
Pump Repair Kit
248204, 255968 248212
253056 287825
248205, 249057, 249059,
257146
248213
Tools Needed
Vise
12 in. adjustable, open end wrench (2)
Hammer, 20 oz maximum
Small screwdriver
Throat Seal Liquid
Pick or long small screwdriver
Cleaning and Inspecting Parts
1. Clean and inspect parts. Pay particular attention to
the ball seats in the intake valve and piston, which
must have no nicks or wear, and to the inside of
the sleeve and the outside of the piston rod, which
must not be worn or scratched. Replace worn or
damaged parts.
WARNING
COMPONENT RUPTURE HAZARD
Never use sharp or pointed tools to
remove sleeve or other components
which could result in pump rupture and
cause serious bodily injury. If the sleeve cannot be
removed easily, return the sleeve and cylinder to
your Graco distributor for removal.
2. Remove and clean the sleeve when you are
repacking the pump.
4 310643
Service
Repair When Pump Is Off The Sprayer
Disassembling the pump
Fig. 1. Remove packing nut (202) and throat adjust-
ment spacer (228).
Fig. 1 7568A
228
ti2332a
202
Fig. 2. Unscrew intake valve from cylinder.
Fig. 2 7569A
Fig. 3. Disassemble intake valve. Clean and inspect.
O-ring (227) may require a pick for removal.
Fig. 3
227
7570e
Fig. 4. Tap piston rod out of cylinder with a hammer or
flip over and tap piston rod out against a bench.
Fig. 4 7571a
Note: Sleeve may come out
of cylinder with piston rod.
Fig. 5. Remove piston rod from sleeve, or remove
sleeve from cylinder. Mark IV: Remove sleeve spacer
(230) from sleeve.
Fig. 5 7572A
5310643
Service
WARNING
COMPONENT RUPTURE HAZARD
Do not clean or wipe the piston valve
threads. Cleaning the piston valve
threads could destroy the special sealing
patch and cause the piston valve to come loose
during operation, causing pump bursting and
possible serious bodily injury.
Fig. 6. Unscrew piston valve from piston rod. Clean
and inspect parts. The piston has a special thread
locking/sealing patch. Do not remove the patch. The
patch allows four disassembly/assembly procedures
before it is necessary to apply Loctiterto the threads.
Fig. 6 7576A
Fig. 7. Remove packings and glands from piston rod.
Fig. 7
Not
used on
248204
253056
255968
ti3940b
Fig. 8. Remove throat packings and glands from cylin-
der. Discard throat packings and glands.
Fig. 8 7573B
Not
used on
248204
253056
255968
Assembling the pump
Fig. 9. Soak all leather packings in SAE 30W oil for 1
hour minimum prior to assembly. Stack male gland
(204) on piston rod. Alternately stack UHMWPE (208)
and leather (218) packings (note orientation) on piston
rod. Install female gland (217). Install piston wiper
(216) (note orientation) and backup washer (229) on
piston valve (210). The special sealing patch on piston
valve threads is good for four repackings. Use Loctiter
on piston valve threads after four repackings.
Fig. 9
216
218 208
204
217
210
Not
used on
248204
253056
255968
7574d
229
6 310643
Service
Fig. 10. Install ball (206) in piston rod. If Loctiteris ap-
plied to piston valve threads, ensure that none gets on
ball.
Fig. 10
206
7575A
Fig. 11. Tighten piston valve to piston rod as specified:
Fig. 11
Torque to 27 +/--3 ft-lb
(248204, 253056, 255968,
277069)
Torque to 55 +/--3 ft-lb
(248205, 249057, 249059,
277070, 257146)
7576A
Fig. 12. Soak all leather packings in SAE 30W oil for 1
hour minimum prior to assembly. Place male gland
(204) in cylinder. Alternately stack UHMWPE (203) and
leather packings (223) (note orientation). Place female
gland (224) in top of cylinder. Seat packings.
Fig. 12
203
224
223
204
Not
used on
248204
253056
255968
7573f
Fig. 13. Install seal (201) into packing nut (202). Install
throat adjustment spacer (228) onto packing nut.
Loosely install packing nut into cylinder.
Fig. 13
201
202
7581A
228
7310643
Service
Fig. 14. Grease piston packings.
Fig. 14 ti7578c
CAUTION
Do not slide piston assembly into top of sleeve as
this may damage piston packing.
Fig. 15. Slide piston assembly into bottom of sleeve.
Fig. 15 7577A
Fig. 16. Grease top inch or two of piston rod that will
go through the cylinder throat packings.
7579A
Fig. 16
Fig. 17. Grease o-rings (221) and place on sleeve.
Slide sleeve/piston rod assembly into bottom of cylind-
er. Replace o-ring (207) if desired.
Note: O-ring (207) is not required for safe pump opera-
tion.
Fig. 17 7582A
221
207
8 310643
Service
Fig. 18. Mark IV: Install o-ring (231) on sleeve spacer
(230) and install sleeve spacer on sleeve.
Fig. 18
ti7340a
231
230
Fig. 19. Reassemble intake valve with new o-ring
(227), seat (212) and ball (214). Seat may be flipped
over and used on other side. Clean seat thoroughly.
Fig. 19
227
7570f
212
214
Fig. 20. Install intake valve on cylinder. If a wrench is
used torque as follows:
67 +/--5 ft-lb (Model 248204, 253056, 255968,
277069)
80 +/--5 ft-lb (Model 248205, 249057, 249059,
277070, 257146 )
If a wrench is not used, be sure intake valve is bot-
tomed out against cylinder.
Fig. 20 7569A
Fig. 21. Torque packing nut (202) down onto adjust-
ment spacer (228) 100 +/--10 in-lb.
Remove throat adjustment spacer (228) when pump
packings begin to leak after much use. Then tighten
packing nut down until leakage stops or lessens. This
allows approximately 100 gallons of additional opera-
tion before a repacking is required.
Fig. 21
202
228
7568A
9310643
Service
Repair When Pump Is On The Sprayer
WARNING
SKIN INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 3.
Fig. 1. Remove intake valve.
Fig. 1 ti4258a
Fig. 2. Push up retaining spring (26).
Fig. 2 26 ti4258a
Fig. 3. Push out pin (29).
Fig. 3
29
26
ti4258a
Fig. 4. Disassemble intake valve. Clean and inspect.
O-ring (227) may require a pick for removal.
Fig. 4 7570A
227
10 310643
Service
Fig. 5. Remove piston rod and sleeve.
7746A
Fig. 5
Fig. 5. Invert piston rod and sleeve and pound on hard
surface until piston rod comes out of sleeve. Mark IV:
Remove sleeve spacer from sleeve.
Fig. 6 7572A
ti7339a
Fig. 7. Remove packing nut (202)
7726A
Fig. 7
202
Fig. 8. Invert piston rod and insert into cylinder to force
out throat packings.
Fig. 8 ti4258a
Fig. 9. Insert piston rod into cylinder with pin hole up
and piston valve down. Insert pin into piston rod and
crank shaft.
Fig. 9 ti4258a
11310643
Service
Fig. 10. Remove piston valve from piston rod with a
wrench.
Fig. 10 ti4258a
Fig. 11. Remove pin and piston rod from cylinder.
Fig. 11 ti4258a
Fig. 12. Soak all leather packings in SAE 30W oil for 1
hour minimum prior to assembly. Stack male gland
(204). Alternately stack UHMWPE (203) and leather
(223) packings (note orientation). Install female gland
(224). Install seal (201) and packing nut (202) and
throat adjustment spacer (228).
Fig. 12
201
228
203
224
223
204
202
Not
used on
248204
253056
255968
7573c
Fig. 13. Remove packings and glands from piston rod.
Fig. 13
Not
used on
248204
253056
255968
ti3939a
12 310643
Service
Fig. 14. Soak all leather packings in SAE 30W oil for 1
hour minimum prior to assembly. Stack male gland
(219) on piston rod. Alternately stack UHMWPE (208)
and leather (218) packings (note orientation) on piston
rod. Install female gland (217). Install piston wiper
(216) and backup washer (229) (note orientation) on
piston valve (210). The special sealing patch on piston
valve threads is good for four repackings. Use Loctiter
on piston valve threads after four repackings.
Fig. 14
210
218
206
208
219 217
Not
used on
248204
253056
255968
ti3941a
229
216
Fig. 10. Install ball (206) in piston rod. If Loctiteris ap-
plied to piston valve threads, ensure that none gets on
ball. Install piston valve on piston rod.
Torque as follows:
27 +/--3 ft-lb (Model 248204, 253056, 255968,
277069)
55 +/--3 ft-lb (Model 248205, 249057, 249059,
277070, 257146)
Fig. 15
206
7575A
Fig. 16. Grease piston packings.
Fig. 16 ti7578c
C
A
UTION
Do not slide piston assembly into top of sleeve as
this may damage piston packing.
Fig. 17. Slide piston assembly into bottom of sleeve.
Assure V-packing and u-cup are not rolled over or
damaged. Mark IV: Install o-ring (231) on sleeve
spacer (230). Install sleeve spacer on sleeve.
Fig. 17
7577b
ti7341a
Mark IV
Fig. 18. Grease top inch or two of piston rod that will
go through the cylinder throat packings.
7579A
Fig. 18
13310643
Service
Fig. 19. Grease o-ring (221) and place on sleeve. Slide
sleeve/piston rod assembly into bottom of cylinder. Re-
place o-ring (207) if desired.
Note: O-ring (207) is not required for safe pump opera-
tion.
Fig. 19
207
221
ti4258a
Fig. 21. Torque seal and packing nut (202) down onto
throat adjustment spacer (228) to 100 +/--10 in-lb.
Remove throat adjustment spacer (228) when pump
packings begin to leak after much use. Then tighten
packing nut down until leakage stops or lessens. This
allows approximately 100 gallons of additional opera-
tion before a repacking is required.
Fig. 20
202
7726b
228
Fig. 21. Push up retaining spring (26) with screwdriver.
Fig. 21 26 ti4258a
Fig. 22. Push in pin (29).
Fig. 22 Note: Make sure retaining ring falls into slot.
29
26
ti4258a
14 310643
Service
Fig. 23. Reassemble intake valve with new o-rings
(227) and (230), seat (212) and ball (214). Seat may
be flipped over and used on other side. Clean seat
thoroughly.
Fig. 23
227
7570f
230
212
214
Fig. 24. Install intake valve on cylinder. Torque:
70 +/--5 ft-lb (model 248204, 253056, 255968,
277069)
80 +/--5 ft-lb (Model 248205, 249057, 249059,
277070, 257146)
Fig. 24 ti4258a
15310643
Service
Fig 25
223 203
218
V-MaxtUHWMPE, blue
208
217
213
214
204
221
224
205
219
215
212
227
222
202
221
216
206
210
Leather
Leather
201
220
228
207
V-MaxtUHWMPE, blue
Pump 248204
2
7683d
229
230
Technical Data
Maximum working pressure 3300 psi...............
(227 bar, 22.7 MPa)
Fluid inlet size 1-5/16--12 un(m)...................
Fluid outlet size
248204, 255968, 277069 1/4 npt(f)................
248205, 249057, 249059, 253056,
277070, 257146 3/8 npt(f).......................
Wetted parts stainless steel, PTFE, leather,..........
nylon, zinc-plated carbon steel, tungsten carbide,
chrome plating, fluoroelastomer, acetal, polyethylene
16 310643
Parts -- Pump 248204, 277069, 255968
Model 248204, Series A; 277069, Series A; 255968, Series A
Ref
No. Part No. Description Qty.
201 179810 SEAL, throat 1
202 193046 NUT, packing 1
203* 192692 V-PACKING, throat, 3
V-MaxtUHMWPE, blue
204* 15C987 GLAND, male, throat 1
205 CYLINDER, pump
243346 Model 248204, 255968 1
243346 Model 277069 1
206* 105444 BALL, sst, 0.3125 in. 1
207* 114054 PACKING, o-ring 1
208* 192693 V-PACKING, piston 3
V-MaxtUHMWPE, blue
210 239932 VALVE, piston 1
212† 239922 KIT, seat, carbide 1
includes 214 and 227
213 15C785 VALVE, intake (foot) 1
Model 248204, 255968
195892 VALVE, intake, Model 277069
214*† 105445 BALL, sst, 0.5000 in. 1
215 192624 GUIDE, ball 1
216* 118503 WIPER, piston 1
217* 178969 GLAND, female, piston 1
218* 178939 V-PACKING, leather, piston 2
219* 196880 GLAND, male 1
220 248209 SLEEVE, cylinder 1
221* 108526 O-RING, PTFE 2
222 248206 ROD, piston 1
223* 178940 V-PACKING, leather, throat 2
224* 15C988 GLAND, female
227*† 107079 PACKING, o-ring 1
228 192714 SPACER, throat, nut 1
229* 15C997 WASHER, backup 1
230* 118494 O-RING, fluoroelastomer (not used
on Lo-boy) 1
* These parts are also included in Repair Kit 248212,
which may be purchased separately.
†These parts are also included in Carbide Seat Kit
239922, which may be purchased separately.
*223
216*
201
202
224*
203*
204*
205
221*
220
222
206*
219*
218*
217*
210
215
212
†
213
†*214
*208
221*
207* †*227
228
ti4255a
229
230*
(Not an O--ring groove)
17310643
Parts -- Pumps 248205, 249057, 249059, 277070, 257146
Model 248205, Series A; 249057, Series A; 249059, Series A; 277070, Series A; 257146, Series A
Ref No.Part No. Description Qty.
201+ 183171 PLUG 1
202 193032 NUT, packing 1
203*+ 193124 V-PACKING 4
V-MaxtUHMWPE, blue
204*+ 15C989 GLAND, packing, male, throat 1
205 CYLINDER, pump 1
243347 Model 248205, 277070
196754 Model 249057, 249059, 257146
206 BALL, 0.375 in.
101947* Model 248205, 249057, 277070,
257146, sst 1
116327+ Model 249059, ceramic 1
207*+ 156633 PACKING, o-ring 1
208*+ 193125 V-PACKING, piston 4
V-MaxtUHMWPE, blue
210 240150 VALVE, piston 1
212† KIT, SEAT, carbide
includes 214 and 227
244199 Model 248205, 249057, 277070,
257146 1
244571 Model 249059 1
213 HOUSING, intake (foot)
15C783 Model 248205, 1
196753 Model 249059, 249057 1
195894 Model 277070, 257146 1
214 BALL
102972*† Model 248205, 249057, 277070, 1
257146 sst, 0.875 in.
111453+ Model 249059, ceramic, 0.750 in. 1
215 GUIDE, ball 1
196967 Model 249059, 249057 1
193027 Model 248205, 277070, 257146 1
216*+ 118504 WIPER, piston 1
217*+ 183185 GLAND, female, piston 1
218*+ 15E329 V-PACKING, leather, piston 3
219*+ 183178 GLAND, packing, male 1
220 SLEEVE, cylinder 1
248210 Model 248205, 249057, 249059,
277070
257031 Model 257146
221*+ 107098 PACKING, o-ring 2
222 ROD, piston
248207 Model 248205, 277070 1
249028 Model 249059, 249057, 257146 1
223*+ 183175 V-PACKING, leather, throat 3
224*+ 15C990 GLAND, packing, female 1
227*†+ 108526 PACKING, o-ring 1
228+ C20987 SPACER, nut 1
229*+ 15C998 WASHER, backup 1
230*+ 118494 O-RING, fluoroelastomer 1
(not used on 249057, 249059, 257146)
231 117608 NIPPLE, straight 1
Model 249057, 249059 (not shown)
232 162485 ADAPTER, 3/8 npt x 3/8 npsm 1
Model 249057, 249059, 257146
(not shown)
* These parts are also included in Repair Kit 248213, which
may be purchased separately.
†These parts are also included in Carbide Seat Kit 244199,
which may be purchased separately
+ These parts are included in Pump Repair Kit 249189.
*223
216*
201
202
224*
203*
204*
205
221*
220
222
206*
219*
218*
217*
210
215
212†
213
†*214
*208
221*
207*
†*227
228
229
230*
(Not an O--ring groove)
18 310643
Parts -- Pump 253056
Ref
No. Part No. Description Qty.
201*§179810 SEAL, throat 1
202 193046 NUT, packing 1
203*§192692 V-PACKING, throat, 3
V-MaxtUHMWPE, blue
204*§15C987 GLAND, male, throat 1
205 287876 CYLINDER, pump 1
206* 105444 BALL, sst, 0.3125 in. (optional) 1
206§119259 BALL, ceramic, 0.3125 in.
(standard) 1
207*§156593 PACKING, o-ring 1
208*§192693 V-PACKING, piston 3
V-MaxtUHMWPE, blue
210 287877 VALVE, piston 1
212†n197470 SEAT, carbide 1
213 287878 HOUSING, intake 1
214*† 102972 BALL, sst, 0.875 in. (optional) 1
214§n 111453 BALL, ceramic, 0.750 (stan-
dard) 1
215 196967 GUIDE, ball 1
216*§118503 WIPER, piston 1
217*§178969 GLAND, female, piston 1
218*§178939 V-PACKING, leather, piston 2
219*§196880 GLAND, male 1
220 248209 SLEEVE, cylinder 1
221*§108526 O-RING, PTFE 2
222 249969 ROD, pump (MARK IV) 1
223*§178940 V-PACKING, leather, throat 2
224*§15C988 GLAND, female
227*† 108526 PACKING, o-ring 1
§n
228*§158776 SPACER, throat, nut 1
229*§15C997 WASHER, backup 1
230 15G494 SPACER, sleeve 1
231*§107098 O-RING 1
* These parts are also included in Repair Kit with
stainless steel ball, 287825, purchased separately.
§These parts are also included in Repair Kit with
ceramic ball, 24V063, purchased separately.
†These parts are also included in Carbide Seat Kit
with stainless steel ball, 244199, purchased sepa-
rately.
nThese parts are also included in Carbide Seat Kit
with ceramic ball, 2V071, purchased separately.
*§223
216*
§
201*§
202
224*§
203*§
204*§
205
221*§
220
222
206*
§
219*§
218*
§
217*§
210
215
212†
n
213
†*§n214
*§208
221*§
207*§
†*§n227
228*§
ti7338a
229*§
230
231*§
(Not an O--ring groove)
19310643
Notes
20 310643
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from
defects in materialand workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended,
or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the
equipmentdetermined by Graco to be defective. This warranty applies only when the equipmentis installed, operated and maintained
in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non--Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipmentwill be returned to the original purchaser transportation prepaid. If inspection of the equipment does notdisclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidentalor consequential damages for lost profits,lost sales,injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD
BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches,
hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in mak-
ing any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
ADDITIONAL WARRANTY COVERAGE
Graco does provide extended warranty and wear warranty for products described in the “Graco Contractor Equipment Warranty
Program”.
TO PLACE AN ORDER, contact your Graco distributor, or call 1--800--690--2894 to identify the nearest distributor.
All written and visual data contained in this document reflect the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
Original insttructions. This manual contains English. MM 310643
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES P.O. BOX 1441 MINNEAPOLIS, MN 55440--1441 USA
Copyright 2003, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
12/2003, Revised January 2014