Graco 311076B Displacement Pump For Reactor E 10 Users Manual 10, Repair Parts, English

2015-04-02

: Graco Graco-311076B-Displacement-Pump-For-Reactor-E-10-Users-Manual-686239 graco-311076b-displacement-pump-for-reactor-e-10-users-manual-686239 graco pdf

Open the PDF directly: View PDF PDF.
Page Count: 10

DownloadGraco Graco-311076B-Displacement-Pump-For-Reactor-E-10-Users-Manual- 311076B - Displacement Pump For Reactor E-10, Repair-Parts, English  Graco-311076b-displacement-pump-for-reactor-e-10-users-manual
Open PDF In BrowserView PDF
Repair - Parts

Displacement Pump

311076B
EN

Part No. 24L006, Series A
3300 psi (22.7 MPa, 227 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.

Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Tools Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Repair Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Clean and Inspect Parts . . . . . . . . . . . . . . . . . . . 4
Pressure Relief . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pump Disassembly . . . . . . . . . . . . . . . . . . . . . . . 4
Pump Reassembly . . . . . . . . . . . . . . . . . . . . . . . . 6
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 10
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 10

TI6993a

Warnings

Warnings
The following general warnings are for the setup, use, grounding, maintenance, and repair of this equipment. Additional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appearing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual,
refer back to these pages for a description of the specific hazard.

WARNING
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
• Read MSDS’s to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
• Do not point gun at anyone or at any part of the body.
• Do not put your hand over the spray tip.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Do not spray without tip guard and trigger guard installed.
• Engage trigger lock when not spraying.
• Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic
drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable
fumes are present.
• Ground equipment and conductive objects in work area. See Grounding instructions.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
• Keep a fire extinguisher in the work area.

2

311076B

Warnings

WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in
all equipment manuals. Read fluid and solvent manufacturer’s warnings.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Do not alter or modify equipment.
• For professional use only.
• Use equipment only for its intended purpose. Call your Graco distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Comply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.

311076B

3

Repair

Repair
Tools Needed

2. Clamp pump intake valve in a vise.

•

Vise with flat jaws

•

12 in. adjustable, open end wrench (2)

3. Loosen packing nut (3) from cylinder (6) using a
hammer and punch, then unscrew. Remove plug (2)
and washers (20). See Fig. 1.

•

Non-sparking hammer, 20 oz maximum

•

Small screwdriver

•

Throat Seal Liquid (TSL), Graco Part No. 206995

•

ISO Pump Oil, Graco Part No. 217374

•

Pick or long small screwdriver

•

3/4 in. deep-well socket

•

Dropcloth and rags

2
3
20

6

Repair Kit
Repair kit 249855 is available for your pump. Kit parts
are marked with an asterisk, for example (3*). Kit must
be purchased separately. For best results, use all parts
in the kit.

TI6995a

FIG. 1
4. Unscrew cylinder (6) from intake valve (17). Remove
o-ring (11). See Fig. 2.

Clean and Inspect Parts
Clean and inspect all parts. Intake and piston ball seats,
cylinder, and displacement rod must not be worn,
scratched, or damaged.
6

Pressure Relief
11

17
Before repair, relieve all system pressure as explained in
your system manual.

TI6996a

FIG. 2

Pump Disassembly
1. Relieve pressure. Remove pump as detailed in your
separate system manual.

4

311076B

Repair

5. Disassemble intake valve (17). Be sure to remove
o-ring (16). See Fig. 3.

14
16

7. Using a 3/4 in. deep well socket, unscrew piston
(10) from rod (1). Remove ball (7), u-cup (8), and
bushing (9). See Fig. 5.

12

1

13
15

17
7

8
10

TI6997a

9
TI6999a

FIG. 3
FIG. 5
6. Tap piston rod assembly with a non-sparking hammer to drive it out of cylinder (6). See Fig. 4.

8. Screw piston (10) part way back onto rod (1), then
insert piston end of rod into cylinder (6) and push
u-cup (5) and bearing (4) out. See Fig. 6.

6

5
4
6

1

TI6998a

FIG. 4
TI7000a

FIG. 6

311076B

5

Repair

Pump Reassembly
Coat all parts that do not use threadlocker with
Graco 217374 ISO Pump Oil before reassembly,
to ease future disassembly. Threadlocker on piston (10) threads can be used three times.

3. Reassemble intake valve with o-ring (16*), seat
(15*), spacer (14*), and ball (13*). Install ball guide
(12).
Seat may be flipped over and used on other
side. Clean seat thoroughly. No scratches permitted on sealing surface.

1. Install ball (7*) in rod (1). Center u-cup (8*) on rod
(1). Lips of u-cup must face up. Use piston (10) to
evenly push u-cup onto rod, then remove piston.
Slide bushing (9) onto rod (1). Wide outside end of
bushing must face up, toward u-cup. Install piston
(10). Be careful not to damage sealing edges of
u-cup. Torque to 24–30 ft/lbs (32.4–40.5 N•m)

12
14
*16

13*

.

15*

1
17
TI6997a

*7

8*

FIG. 9

*9

10

TI7001a
TI6999a

4. Use your fingers to replace o-ring (11*). Install
intake valve. Torque housing (17) to approximately
55–65 ft/lb (74.25–87.75 N•m), or be sure intake
valve is snug against cylinder.

FIG. 7
2. Lubricate piston u-cup (8*). Push piston assembly
into bottom of cylinder (6). Drive in with a non-sparking hammer
.

*11

6

17

TI6996a

FIG. 10
8*

TI7005a

FIG. 8

6

311076B

Repair

5. Install throat u-cup (5*). Grease u-cup and cylinder
(6). U-cup lips must be facing down. Press u-cup
carefully over rod wrench flats, then into cylinder
with a 3/4 in. deep-well socket (A). Remove socket.

7. Screw packing nut assembly (3) into cylinder (6).
Hand tighten, then tighten securely with a punch
and hammer.

2*
3

20*

6
A

5*
TI7002a

6

TI7003a

FIG. 11
TI6995a

6. Insert bushing (4*) into cylinder. Press bushing in
place to seat u-cup against shoulder in cylinder (6).

FIG. 13
8. Expose 1/2 in. (12.7 mm) of polished section of rod
by inserting screwdriver into pinhole and twisting
while carefully pulling up. This will leave enough rod
exposed for mounting on the drive housing.

*4

6
1/2 in.
(12.7 mm)
TI7004a

FIG. 12

Assemble felt washers (20) into packing nut (3),
and retain with plastic cap (2). Soak assembly in
217374 ISO oil for a minimum 10 minutes before
assembling on pump.

TI7075a

FIG. 14

311076B

7

Parts

Parts
Part No. 24L006, Displacement Pump

2*
20*

*4
*5

3

6
1
11*
12

*8

13*†

*9

14†
15*†
*7
16*†
10
17
TI6994a

Ref.
No.
1
2*
3
4*
5*
6
7*
8*
9*
10
11*
12
13*†

8

Part No.
249125
180656
193047
15F745
15F747
243176
105444
15F748
15F746

Description
Qty.
ROD, piston (includes #10 piston)
1
PLUG, button
1
NUT, packing
1
BUSHING, rod
1
SEAL, u-cup, rod
1
CYLINDER, pump
1
BALL, piston
1
SEAL, u-cup, piston
1
BUSHING, piston
1
VALVE, piston (included in #1)
1
108526 PACKING, o-ring
1
196896 GUIDE, ball
1
105445 BALL, intake
1

Ref.
No.
14†
15*†
16*†
17
20*
*

Part No.
195134
195132
195136
196755
117603

Description
SPACER, ball, guide
SEAT, intake valve, carbide
O-RING, special
HOUSING, valve, intake
WASHER, felt

Qty.
1
1
1
1
2

Parts included in Kit 249855 (purchase separately).

† Parts included in Kit 243190

311076B

Technical Data

Technical Data
Category
Maximum working pressure (pump only)
Effective area of displacement
Fluid inlet size
Fluid outlet size
Wetted parts
Stroke Length
Volume Per Cycle (single pump)

311076B

Data
3300 psi (22.7 MPa, 227 bar)
0.301 in.2 (1.94 cm2)
3/4 npt(f)
1/4 npt(f)
stainless steel, PTFE, zinc-plated carbon steel, acetal, tungsten carbide,
chrome plating, ultra-high molecular weight polyethylene
0.72 in. (18.29 mm) on E-10 Reactor
.00176 gal. (.0066 Liter)

9

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 311076

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2005, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revised 10/20111



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-701
Job Ref                         : Z067322
Web Statement                   : Displacement Pump for Reactor E-10
Producer                        : Acrobat Distiller 7.0 (Windows)
Keywords                        : "Displacement Pump, 24L006, Reactor E-10" nopct
Copyright                       : 2005, Rev. B 10/2011
Marked                          : True
Create Date                     : 2005:04:27 11:19:54Z
Modify Date                     : 2011:10:13 14:22:25-05:00
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2011:10:13 14:22:25-05:00
Format                          : application/pdf
Creator                         : Cari Wolfe
Description                     : Displacement Pump
Title                           : 311076B - Displacement Pump for Reactor E-10, Repair-Parts, English
Subject                         : Displacement Pump, 24L006, Reactor E-10, nopct
Document ID                     : uuid:2b046808-68f6-4e82-904e-a4fd690526d0
Instance ID                     : uuid:6bb8e002-df1b-45f3-9349-e2b3e1c9fa64
Page Count                      : 10
Author                          : Cari Wolfe
EXIF Metadata provided by EXIF.tools

Navigation menu