Graco 312760S Pr70 And Pr70V Users Manual PR70v, Repair Parts, English

2015-04-02

: Graco Graco-312760S-Pr70-And-Pr70V-Users-Manual-685886 graco-312760s-pr70-and-pr70v-users-manual-685886 graco pdf

Open the PDF directly: View PDF PDF.
Page Count: 86

DownloadGraco Graco-312760S-Pr70-And-Pr70V-Users-Manual- 312760S - PR70 And PR70v, Repair Parts, English  Graco-312760s-pr70-and-pr70v-users-manual
Open PDF In BrowserView PDF
Repair - Parts

PR70 and PR70v

312760S
EN

Two Component Liquid Dispensing Systems

Fixed or variable ratio systems. For accurate metering, mixing, and dispensing of
two-component materials. For professional use only.
Not approved for use in European explosive atmosphere locations.
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Important Safety Instructions
Read all warnings and instructions in all
supplied manuals. Save these instructions.

ti12385b

PR70v Shown with Advanced Display Module

Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Configurator . . . . . . . . . . . . . . . . . . . . . . . 4
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Pressure Relief Procedure . . . . . . . . . . . . . . . . . . 14
Models with Advanced Display Module . . . . . . . 14
Models with Standard Display Module . . . . . . . 14
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Error Codes
(Advanced Display Module) . . . . . . . . . . . . 18
Error Codes
(Standard Display Module) . . . . . . . . . . . . . 23
Electrical Schematics . . . . . . . . . . . . . . . . . . . . . . 25
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
HydraCheck Kit Installation . . . . . . . . . . . . . . . . 29
Air Cylinder Kit Installation . . . . . . . . . . . . . . . . 31
Rear Pump Rebuild Kit Installation . . . . . . . . . . 33
Piston/Cylinder Replacement Kit Installation . . 35
Check Valve Rebuild Kit Installation . . . . . . . . . 36
Piston Plug Installation . . . . . . . . . . . . . . . . . . . 37
Pressure Transducer Installation . . . . . . . . . . . . 37
Flow Meter Installation . . . . . . . . . . . . . . . . . . . 38
Fluid Control Module Replacement . . . . . . . . . . 39
Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . 40

2

Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Fixed Ratio Base, LC0262, LC0263, LC0264,
LC0265 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Fixed Ratio Frame Sub-Assembly, LC0290 . . . . 44
Fixed Ratio Drive Block Assembly, LC0107 . . . . 45
Variable Ratio Base, LC0242, LC0243, LC0244,
LC0245 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Variable Ratio Frame Sub-Assembly, LC0232 . . 49
Air Cylinder, LC0110, LC0111, LC0230, LC0231 52
Pump Sub-Assembly, LC0112 . . . . . . . . . . . . . . 54
Control Bracket, LC0240, LC0261 . . . . . . . . . . . 56
Incoming Power Bracket, LC0239 . . . . . . . . . . . 58
Piston Package . . . . . . . . . . . . . . . . . . . . . . . . . 60
Nylon and UHMW Piston Replacement Kits . . . 63
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Applicator Mounting . . . . . . . . . . . . . . . . . . . . . . 65
Dispense Valve . . . . . . . . . . . . . . . . . . . . . . . . . 66
Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Hose Packages . . . . . . . . . . . . . . . . . . . . . . . . . 69
Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Flow Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 77
Tank Stands, Assemblies LC0247 and LC0103 79
Heat Zone Assemblies . . . . . . . . . . . . . . . . . . . 79
Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Machine with On-Board Tanks . . . . . . . . . . . . . . 82
Machine with Off-Board Tanks . . . . . . . . . . . . . . 83
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 86
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 86

312760S

Related Manuals

Related Manuals
PR70 and PR70v Operation and Parts Manuals
Part

Description

3A0429

PR70 with Standard Display Module Operation and
Maintenance Manual

312759

PR70 and PR70v with Advanced Display Module
Operation and Maintenance Manual

312760

PR70 and PR70v Repair and Parts Manual

312394

PR70 and PR70v Feed Systems Manual

312761

PR70v Integrated Heat Instructions - Parts Manual

MD2 Dispense Valve Manual
Part

Description

312185

MD2 Dispense Valve Instructions and Parts Manual

312760S

3

Product Configurator

Product Configurator
PR7F -

-

-

-

-

-

-

-

-

-

-

-

-

I-J

K

L

M

N

O

P

Q

R

S

T

U

V

Mixer

Applicator Mounting

Power Cord

Flow Monitoring

High Volume Side Tank

High Volume Side Tank Cover

Low Volume Side Tank

Low Volume Side Tank Cover

Tank Level Sensors

Heat Zone Controller

Off-Board Tank Stand

G-H

Dispense Valve

F

High Volume Side Hose

High Volume Side Piston

Air Motor

D-E

Low Volume Side Hose

B-C

Controls

A

Low Volume Side Piston

Code:

-

An example of the product configurator would be the following configurator code.
PR7F - J - A5 - A5 - E - A6 - A6 - 3 - 1 - 2 - A - N - 3 - N - H - N - 6 - N - N
S

T

U

V
Off-Board Tank Stand

R

Heat Zone Controller

Q

Tank Level Sensors

P

Low Volume Side Tank Cover

O

Low Volume Side Tank

N

High Volume Side Tank Cover

M

High Volume Side Tank

L

Flow Monitoring

Controls

K

Power Cord

Low Volume Side Piston

I-J

Applicator Mounting

High Volume Side Piston

G-H

Mixer

F

Dispense Valve

D-E

Low Volume Side Hose

B-C

High Volume Side Hose

A
Air Motor

Code:

The following part number fields apply for the PR70 and PR70v part numbering configurator fields. Shaded items
listed in the configurator table below are “Super Standard” items that are typically stocked and provide the best delivery dates.
Code A
A
B
C

LC0262
LC0264
LC0263

D

LC0265

F
G

LC0242
LC0244

H

LC0243

J

4

Part

LC0245

Air Motor
PR70 with 3.0 in. (4.56 mm) Air Motor
PR70 with 4.5 in. (10.26 mm) Air Motor
PR70 with 3.0 in. (4.56 mm) Air Motor
and Hydracheck
PR70 with 4.5 in. (10.26 mm) Air Motor
and Hydracheck
PR70v with 3.0 in. (4.56 mm) Air Motor
PR70v with 4.5 in. (10.26 mm) Air
Motor
PR70v with 3.0 in. (4.56 mm) Air Motor
and Hydracheck
PR70v with 4.5 in. (10.26 mm) Air
Motor and Hydracheck

Code B

Part

A

LC1___

B

LC2___

C

LC3___

Code C

Part

1
2
3

High Volume Side Piston and
Metering Tube Material
Nylon Piston, Stainless Steel Metering
Tube (last three digits of part number
is the mm2 piston size)
UHMWPE Piston, Stainless Steel
Metering Tube (last three digits of part
number is the mm2 piston size)
UHMWPE Piston, Ceramic Metering
Tube (last three digits of part number
is the mm2 piston size)
High Volume Piston Size (mm2)
80, Available in Nylon Only
100, Available in Nylon Only
120, Available in Nylon Only

312760S

Product Configurator

4
5
6
7
8
9
A
B
C
F
G
H
J
L
M
R
S
T
U
W
X
Y
Z

140, Available in Nylon Only
160
180
200
220
240
260
280
300
320
360
400
440
480
520
560
600
640
720
800
880
960
Custom High Volume side, consult factory (stainless steel only)

Code D

Part

A

LC1___

B

LC2___

C

LC3___

Code E

Part

1
2
3
4
5
6
7
8
9
A
B
C
F
G
H
312760S

High Volume Side Piston and
Metering Tube Material
Nylon Piston, Stainless Steel Metering
Tube (last three digits of part number
is the mm2 piston size)
UHMWPE Piston, Stainless Steel
Metering Tube (last three digits of part
number is the mm2 piston size)
UHMWPE Piston, Ceramic Metering
Tube (last three digits of part number
is the mm2 piston size)
Low Volume Side Piston Size (mm2)
80, Available in Nylon Only
100, Available in Nylon Only
120, Available in Nylon Only
140, Available in Nylon Only
160
180
200
220
240
260
280
300
320
360
400

J
L
M
R
S
T
U
W
X
Y
Z

440
480
520
560
600
640
720
800
880
960
Custom Low Volume side, consult factory (stainless steel only)

Code F

Part

Controls

B

LC0272

D

LC0274

E

LC0275

Standard Display Module with 1 Fluid
Control Module
Advanced Display Module with 1 Fluid
Control Module
Advanced Display Module with 2 Fluid
Control Modules

Codes
G-H,
I-J

Part

A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AG
AH
B4
B5
B6
B7
B8
B9
BA
BB
BC
BG
BH
C1

LC0801
LC0802
LC0803
LC0804
LC0805
LC0806
LC0807
LC0808
LC0809
LC0810
LC0811
LC0812
LC0813
LC0814
LC0881
LC0882
LC0883
LC0884
LC0885
LC0886
LC0887
LC0888
LC0889
LC0890
LC0891
LC0161

C2

LC0162

High Volume Hose /
Low Volume Hose
3/16 in. (4.8 mm) - 2.5 ft (0.6 m)
3/16 in. (4.8 mm) - 10 ft (3.0 m)
3/16 in. (4.8 mm) - 15 ft (4.6 m)
1/4 in. (6.5 mm) - 2.5 ft (0.6 m)
1/4 in. (6.5 mm) - 10 ft (3.0 m)
1/4 in. (6.5 mm) - 15 ft (4.6 m)
3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
3/8 in. (9.5 mm) - 10 ft (3.0 m)
3/8 in. (9.5 mm) - 15 ft (4.6 m)
1/2 in. (13 mm) - 2.5 ft (0.6 m)
1/2 in. (13 mm) - 10 ft (3.0 m)
1/2 in. (13 mm) - 15 ft (4.6 m)
3/4 in. (19 mm) - 10 ft (3.0 m)
3/4 in. (19 mm) - 15 ft (4.6 m)
Heated, 1/4 in. (6.5 mm) - 2.5 ft (0.6 m)
Heated, 1/4 in. (6.5 mm) - 10 ft (3.0 m)
Heated, 1/4 in. (6.5 mm) - 15 ft (4.6 m)
Heated, 3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
Heated, 3/8 in. (9.5 mm) - 10 ft (3.0 m)
Heated, 3/8 in. (9.5 mm) - 15 ft (4.6 m)
Heated, 1/2 in. (13 mm) - 2.5 ft (0.6 m)
Heated, 1/2 in. (13 mm) - 10 ft (3.0 m)
Heated, 1/2 in. (13 mm) - 15 ft (4.6 m)
Heated, 3/4 in. (19 mm) - 10 ft (3.0 m)
Heated, 3/4 in. (19 mm) - 15 ft (4.6 m)
Recirculating, On-Board Tanks,
3/16 in. (4.8 mm) - 2.5 ft (0.6 m)
Recirculating, On-Board Tanks,
3/16 in. (4.8 mm) - 10 ft (3.0 m)

5

Product Configurator

6

C3

LC0163

C4

LC0164

C5

LC0165

C6

LC0166

C7

LC0167

C8

LC0168

C9

LC0169

CA

LC0170

CB

LC0171

CC

LC0172

CD

LC0173

CE

LC0174

D1

LC0175

D2

LC0176

D3

LC0177

D4

LC0178

D5

LC0179

D6

LC0180

D7

LC0181

D8

LC0182

D9

LC0183

DA

LC0184

DB

LC0185

DC

LC0186

DD

LC0187

DE

LC0188

E1

LC0190

Recirculating, On-Board Tanks,
3/16 in. (4.8 mm) - 15 ft (4.6 m)
Recirculating, On-Board Tanks,
1/4 in. (6.5 mm) - 2.5 ft (0.6 m)
Recirculating, On-Board Tanks,
1/4 in. (6.5 mm) - 10 ft (3.0 m)
Recirculating, On-Board Tanks,
1/4 in. (6.5 mm) - 15 ft (4.6 m)
Recirculating, On-Board Tanks,
3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
Recirculating, On-Board Tanks,
3/8 in. (9.5 mm) - 10 ft (3.0 m)
Recirculating, On-Board Tanks,
3/8 in. (9.5 mm) - 15 ft (4.6 m)
Recirculating, On-Board Tanks,
1/2 in. (13 mm) - 2.5 ft (0.6 m)
Recirculating, On-Board Tanks,
1/2 in. (13 mm) - 10 ft (3.0 m)
Recirculating, On-Board Tanks,
1/2 in. (13 mm) - 15 ft (4.6 m)
Recirculating, On-Board Tanks,
3/4 in. (19 mm) - 10 ft (3.0 m)
Recirculating, On-Board Tanks,
3/4 in. (19 mm) - 15 ft (4.6 m)
Recirculating, Off-Board Tanks,
3/16 in. (4.8 mm) - 2.5 ft (0.6 m)
Recirculating, Off-Board Tanks,
3/16 in. (4.8 mm) - 10 ft (3.0 m)
Recirculating, Off-Board Tanks,
3/16 in. (4.8 mm) - 15 ft (4.6 m)
Recirculating, Off-Board Tanks,
1/4 in. (6.5 mm) - 2.5 ft (0.6 m)
Recirculating, Off-Board Tanks,
1/4 in. (6.5 mm) - 10 ft (3.0 m)
Recirculating, Off-Board Tanks,
1/4 in. (6.5 mm) - 15 ft (4.6 m)
Recirculating, Off-Board Tanks,
3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
Recirculating, Off-Board Tanks,
3/8 in. (9.5 mm) - 10 ft (3.0 m)
Recirculating, Off-Board Tanks,
3/8 in. (9.5 mm) - 15 ft (4.6 m)
Recirculating, Off-Board Tanks,
1/2 in. (13 mm) - 2.5 ft (0.6 m)
Recirculating, Off-Board Tanks,
1/2 in. (13 mm) - 10 ft (3.0 m)
Recirculating, Off-Board Tanks,
1/2 in. (13 mm) - 15 ft (4.6 m)
Recirculating, Off-Board Tanks,
3/4 in. (19 mm) - 10 ft (3.0 m)
Recirculating, Off-Board Tanks,
3/4 in. (19 mm) - 15 ft (4.6 m)
Recirculating, Heated, On-Board
Tanks, 1/4 in. (6.5 mm) - 2.5 ft (0.6 m)

E2

LC0191

E3

LC0192

E4

LC0193

E5

LC0194

E6

LC0195

E7

LC0196

E8

LC0197

E9

LC0198

EA

LC0199

EB

LC0200

F1

LC0201

F2

LC0202

F3

LC0203

F4

LC0204

F5

LC0205

F6

LC0206

F7

LC0207

F8

LC0208

F9

LC0209

FA

LC0210

FB

LC0211

GA

LC0400

GB

LC0401

GC

LC0402

GD

LC0403

GE

LC0404

GF

LC0405

Recirculating, Heated, On-Board
Tanks, 1/4 in. (6.5 mm) - 10 ft (3.0 m)
Recirculating, Heated, On-Board
Tanks, 1/4 in. (6.5 mm) - 15 ft (4.6 m)
Recirculating, Heated, On-Board
Tanks, 3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
Recirculating, Heated, On-Board
Tanks, 3/8 in. (9.5 mm) - 10 ft (3.0 m)
Recirculating, Heated, On-Board
Tanks, 3/8 in. (9.5 mm) - 15 ft (4.6 m)
Recirculating, Heated, On-Board
Tanks, 1/2 in. (13 mm) - 2.5 ft (0.6 m)
Recirculating, Heated, On-Board
Tanks, 1/2 in. (13 mm) - 10 ft (3.0 m)
Recirculating, Heated, On-Board
Tanks, 1/2 in. (13 mm) - 15 ft (4.6 m)
Recirculating, Heated, On-Board
Tanks, 3/4 in. (19 mm) - 10 ft (3.0 m)
Recirculating, Heated, On-Board
Tanks, 3/4 in. (19 mm) - 15 ft (4.6 m)
Recirculating, Heated, Off-Board
Tanks, 1/4 in. (6.5 mm) - 2.5 ft (0.6 m)
Recirculating, Heated, Off-Board
Tanks, 1/4 in. (6.5 mm) - 10 ft (3.0 m)
Recirculating, Heated, Off-Board
Tanks, 1/4 in. (6.5 mm) - 15 ft (4.6 m)
Recirculating, Heated, Off-Board
Tanks, 3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
Recirculating, Heated, Off-Board
Tanks, 3/8 in. (9.5 mm) - 10 ft (3.0 m)
Recirculating, Heated, Off-Board
Tanks, 3/8 in. (9.5 mm) - 15 ft (4.6 m)
Recirculating, Heated, Off-Board
Tanks, 1/2 in. (13 mm) - 2.5 ft (0.6 m)
Recirculating, Heated, Off-Board
Tanks, 1/2 in. (13 mm) - 10 ft (3.0 m)
Recirculating, Heated, Off-Board
Tanks, 1/2 in. (13 mm) - 15 ft (4.6 m)
Recirculating, Heated, Off-Board
Tanks, 3/4 in. (19 mm) - 10 ft (3.0 m)
Recirculating, Heated, Off-Board
Tanks, 3/4 in. (19 mm) - 15 ft (4.6 m)
High Pressure, 3/8 in. (9.5 mm) - 2.5 ft
(0.6 m)
High Pressure, 3/8 in. (9.5 mm) - 10 ft
(3.0 m)
High Pressure, 3/8 in. (9.5 mm) - 15 ft
(4.6 m)
High Pressure, 1/2 in. (13 mm) - 2.5 ft
(0.6 m)
High Pressure, 1/2 in. (13 mm) - 10 ft
(3.0 m)
High Pressure, 1/2 in. (13 mm) - 15 ft
(4.6 m)

312760S

Product Configurator

GH

LC0406

GJ

LC0407

GK

LC0432

GL

LC0433

GM

LC0434

GQ

LC0435

GR

LC0436

GS

LC0437

GT

LC0438

GU

LC0439

GW

LC0440

GX

LC0441

GY

LC0442

G1

LC0443

G2

LC0444

G3

LC0445

G4

LC0446

G5

LC0447

HA

LC0472

HB

LC0473

312760S

High Pressure, 3/4 in. (19 mm) - 10 ft
(3.0 m)
High Pressure, 3/4 in. (19 mm) - 15 ft
(4.6 m)
High Pressure, Recirculating,
On-Board Tanks,
3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
High Pressure, Recirculating,
On-Board Tanks,
3/8 in. (9.5 mm) - 10 ft (3.0 m)
High Pressure, Recirculating,
On-Board Tanks,
3/8 in. (9.5 mm) - 15 ft (4.6 m)
High Pressure, Recirculating,
On-Board Tanks,
1/2 in. (13 mm) - 2.5 ft (0.6 m)
High Pressure, Recirculating,
On-Board Tanks,
1/2 in. (13 mm) - 10 ft (3.0 m)
High Pressure, Recirculating,
On-Board Tanks,
1/2 in. (13 mm) - 15 ft (4.6 m)
High Pressure, Recirculating,
On-Board Tanks,
3/4 in. (19 mm) - 10 ft (3.0 m)
High Pressure, Recirculating,
On-Board Tanks,
3/4 in. (19 mm) - 15 ft (4.6 m)
High Pressure, Recirculating,
On-Board Tanks,
3/8 in. (9.5 mm) - 2.5 ft (0.6 m)
High Pressure, Recirculating,
On-Board Tanks,
3/8 in. (9.5 mm) - 10 ft (3.0 m)
High Pressure, Recirculating,
On-Board Tanks,
3/8 in. (9.5 mm) - 15 ft (4.6 m)
High Pressure, Recirculating,
On-Board Tanks,
1/2 in. (13 mm) - 2.5 ft (0.6 m)
High Pressure, Recirculating,
On-Board Tanks,
1/2 in. (13 mm) - 10 ft (3.0 m)
High Pressure, Recirculating,
On-Board Tanks,
1/2 in. (13 mm) - 15 ft (4.6 m)
High Pressure, Recirculating,
On-Board Tanks,
3/4 in. (19 mm) - 10 ft (3.0 m)
High Pressure, Recirculating,
On-Board Tanks,
3/4 in. (19 mm) - 15 ft (4.6 m)
High Pressure, Heated, 3/8 in. (9.5
mm) - 2.5 ft (0.6 m)
High Pressure, Heated, 3/8 in. (9.5
mm) - 10 ft (3.0 m)

HC

LC0474

HF

LC0475

HG

LC0476

HJ

LC0477

HL

LC0478

HM

LC0479

HQ

LC0480

HR

LC0481

HS

LC0482

HT

LC0483

HU

LC0484

HX

LC0485

HY

LC0486

H2

LC0487

NN

---

Code K

Part

N
2
3
4
5
6
7

N/A
255179
255181
LC0120
LC0122
LC0121
LC0123

Code L

Part

N
1
2
3
4
5
6
7
8
9

N/A
LC0063
LC0057
LC0058
LC0059
LC0060
LC0062
LC0061
LC0295
LC0296

High Pressure, Heated, 3/8 in. (9.5
mm) - 15 ft (4.6 m)
High Pressure, Heated, 1/2 in. (13
mm) - 2.5 ft (0.6 m)
High Pressure, Heated, 1/2 in. (13
mm) - 10 ft (3.0 m)
High Pressure, Heated, 1/2 in. (13
mm) - 15 ft (4.6 m)
High Pressure, Heated, 3/4 in. (19
mm) - 10 ft (3.0 m)
High Pressure, Heated, 3/4 in. (19
mm) - 15 ft (4.6 m)
High Pressure, Heated, 3/8 in. (9.5
mm) - 2.5 ft (0.6 m)
High Pressure, Heated, 3/8 in. (9.5
mm) - 10 ft (3.0 m)
High Pressure, Heated, 3/8 in. (9.5
mm) - 15 ft (4.6 m)
High Pressure, Heated, 1/2 in. (13
mm) - 2.5 ft (0.6 m)
High Pressure, Heated, 1/2 in. (13
mm) - 10 ft (3.0 m)
High Pressure, Heated, 1/2 in. (13
mm) - 15 ft (4.6 m)
High Pressure, Heated, 3/4 in. (19
mm) - 10 ft (3.0 m)
High Pressure, Heated, 3/4 in. (19
mm) - 15 ft (4.6 m)
Not required
Dispense Valve
None
MD2, Valve Only with 1:1 Nose
MD2, Valve Only with 10:1 Nose
MD2, Handheld with 1:1 Nose
MD2, Handheld with 10:1 Nose
MD2, Lever with 1:1 Nose
MD2, Lever with 10:1 Nose
Mixer Type
None
3/16 in. (4.8 mm) x 32
1/4 in. (6.4 mm) x 24
3/8 in. (9.5 mm) x 24
3/8 in. (9.5 mm) x 36
3/8 in. (9.5 mm) Combo
1/4 in. (6.4 mm) x 24 Luer Lock
3/16 in. (4.8 mm) x 32 Luer Lock
1/2 in. (12.7 mm) x 24
1/2 in. (12.7 mm) x 36

7

Product Configurator

Code M

Part

Applicator Mounting

Code P

Part

High Volume Side Tank

N

LC0294

1

LC0292

N
1
2
3

N/A
256896
255241
255250

2
3

LC0293
256439

4

255251

5

255281

6

255282

7

255283

8

LC0235★

9

LC0236★

A
B
C

LC0013★
LC0012★
255285★

D

LC0156

E

LC0157

F

255284★

G
H

LC0254★
LC0255★

J
K

LC0054
LC0158

L
M
P

LC0259
LC0055
LC0159

R
S

LC0260
LC0126

T

LC0127

U

LC0128

V

LC0238★

None
No Tanks, 1 1/2 in. npt flange
8 L, Twin Polyethylene Tanks and Lids
8 L, Twin Polyethylene Tanks and Lids,
One 120V Agitator
8 L, Twin Polyethylene Tanks and Lids,
Two 120V Agitators
8 L, Twin Polyethylene Tanks and Lids,
with Shut-Off Valves
8 L, Twin Polyethylene Tanks and Lids,
One 120V Agitator, with Shut-Off
Valves
8 L, Twin Polyethylene Tanks and Lids,
Two 120V Agitators, with Shut-Off
Valves
7.5 L, Stainless Steel, High Level Sensors
7.5 L, Stainless Steel, High Level Sensors, with Shut-Off Valve
3 L, Stainless Steel
7.5 L, Stainless Steel
3 L, Stainless Steel, with Shut-Off
Valve
8 L, Twin Polyethylene Tanks and Lids,
One Pneumatic Agitator
8 L, Twin Polyethylene Tanks and Lids,
Two Pneumatic Agitator
7.5 L, Stainless Steel, with Shut-Off
Valve
7.5 L, Stainless Steel, 240V Heat
7.5 L, Stainless Steel, 240V Heat,
with Shut-Off Valve
30 L, Stainless Steel
8 L, Twin Polyethylene Tanks and Lids,
One Pneumatic Agitator, with Shut-Off
Valves
30 L, Stainless Steel, 240V Heat
60 L, Stainless Steel
8 L, Twin Polyethylene Tanks and Lids,
Two Pneumatic Agitators, with
Shut-Off Valves
60 L, Stainless Steel, 240V Heat
8 L, Twin Polyethylene Tanks and Lids,
One 240V Agitator
8 L, Twin Polyethylene Tanks and Lids,
Two 240V Agitators
8 L, Twin Polyethylene Tanks and Lids,
One 240V Agitator, with Shut-Off
Valves
7.5 L, Stainless Steel, High Level Sensors, 240V Heat, with Shut-Off Valve

4

256438

None, Customer Mount Controls and
Applicator
Mast Mount, Controls & MD2 Applicator Machine Mounted
Mast Mount, Controls Only
Tank Stand Mount, Controls & MD2
Applicator Machine Mounted
Tank Stand Mount, Controls Only

Code N

Part

Power Cord Option

1
2
3
4
5
6
7
8
9
A
B

121055
121054
121056
121057
121058
124864
124861
124863
124862
121060
N/A

Code O

Part

Flow Monitoring

N
1
2

LC0041
257433
LC0302

3

LC0305

4

LC0303

5

LC0307

6

LC0306

7

LC0304

A

LC0312

B

LC0315

C

LC0313

None
Pressure Transducer
Two 0.5 gpm Flow Meters, No Pressure Transducers
Two 1.0 gpm Flow Meters, No Pressure Transducers
One 1.0 gpm Flow Meter, One
0.5 gpm Flow Meter, No Pressure
Transducers
Two 2.0 gpm Flow Meters, No Pressure Transducers
One 2.0 gpm Flow Meter, One
1.0 gpm Flow Meter, No Pressure
Transducers
One 2.0 gpm Flow Meter, One 0.5 gpm
Flow Meter, No Pressure Transducers
Two 0.5 gpm Flow Meters, With Pressure Transducers
Two 1.0 gpm Flow Meters, With Pressure Transducers
One 1.0 gpm Flow Meter, One
0.5 gpm Flow Meter, With Pressure
Transducers
Two 2.0 gpm Flow Meters, With Pressure Transducers
One 2.0 gpm Flow Meter, One
1.0 gpm Flow Meter, With Pressure
Transducers
One 2.0 gpm Flow Meter, One 0.5 gpm
Flow Meter, With Pressure Transducers

D

LC0317

E

LC0316

F

8

LC0314

120VAC North American Cord Set
10A, 250V US Cord Set
10A, 250V Continental europe
10A, 250V U.K./Ireland
10A, 250V Israel
10A, 250V Australia
10A, 250V Italy
10A, 250V Switzerland
10A, 250V Denmark
10A, 250V India
Heat Controller Option

312760S

Product Configurator

W

LC0129

X
Y
Z

LC0160
LC0297
LC0237★

---

★

8 L, Twin Polyethylene Tanks and Lids,
Two 240V Agitators, with Shut-Off
Valves
Accumulator, Fluoroelastomer
Accumulator, EP
7.5 L, Stainless Steel, High Level Sensors, 240V Heat
When ordering tanks for spare or
replacement parts, refer to Parts section of the PR70 and PR70v Feed Systems manual.

Code Q

Part

High Volume Side Tank Cover

N
1
2
3
4
5
6

N/A
LC0018
LC0019
LC0020
LC0021
LC0022
LC0023

7

LC0024

8

LC0025

9

LC0026

A
B
C
F
G
H
K

LC0142
LC0101
LC0043
LC0102
LC0047
LC0048
LC0147

M

LC0051

R

LC0052

S
T
U

LC0130
LC0131
LC0132

None
On-Board Dust Cover
On-Board Clamp Down
On-Board Vacuum De-gas
On-Board Agitate 120VAC 50/60 Hz
On-Board Agitate 240VAC 50/60 Hz
On-Board Agitate 120 VAC 50/60 Hz
and De-gas
On-Board Agitate 240 VAC 50/60 Hz
and De-gas
On-Board 120VAC 50/60 Hz, De-gas
and Fill-Port
On-Board 240 VAC 50/60 Hz, De-gas
and Fill-Port
Off-Board Clamp Down - 30L
Off-Board Clamp Down - 60L
Off-Board Vacuum De-gas - 30L
Off-Board Vacuum De-gas - 60L
Off-Board Electric Agitator - 30L
Off-Board Electric Agitator - 60L
Off-Board Vacuum De-gas, Pneumatic Agitator, Fill Port, Slinger - 60 L
Off-Board Vacuum De-gas, Electric
Agitator, Fill Port, Slinger - 30 L
Off-Board Vacuum De-gas, Electric
Agitator, Fill Port, Slinger - 60 L
On-Board, Pneumatic Agitate
On-Board, Pneumatic Agitate, De-gas
On-Board, Pneumatic Agitate, De-gas,
Fill Port
Off-Board Pneumatic Agitator - 30 L
Off-Board Pneumatic Agitator - 60 L
Off-Board Vacuum De-gas, Pneumatic Agitator, Fill Port, Slinger - 30 L

V
W
Z

LC0142
LC0143
LC0146

Code R

Part

Low Volume Side Tank

N
1
8

N/A
256896
LC0235★

None
No Tanks, 1 1/2 in. npt flange
7.5 L, Stainless Steel, High Level Sensors

312760S

9

LC0236★

7.5 L, Stainless Steel, High Level Sensors,
with Shut-Off Valve
3 L, Stainless Steel
7.5 L, Stainless Steel
3 L, Stainless Steel, with Shut-Off
Valve
7.5 L, Stainless Steel, with Shut-Off
Valve
7.5 L, Stainless Steel, 240V Heat
7.5 L, Stainless Steel, 240V Heat,
with Shut-Off Valve
30 L, Stainless Steel
30 L, Stainless Steel, 240V Heat
60 L, Stainless Steel
60 L, Stainless Steel, 240V Heat
7.5 L, Stainless Steel, High Level Sensors,
240V Heat, with Shut-Off Valve
Accumulator, Fluoroelastomer
Accumulator, EP
7.5 L, Stainless Steel, High Level Sensors,
240V Heat
When ordering tanks for spare or
replacement parts, refer to Parts section of the PR70 and PR70v Feed Systems manual.

A
B
C

LC0013★
LC0012★
255285★

F

255284★

G
H

LC0254★
LC0255★

J
L
M
R
V

LC0054
LC0259
LC0055
LC0260
LC0238★

X
Y
Z

LC0160
LC0297
LC0237★

---

★

Code S

Part

Low Volume Side Tank Covers

N
1
2
3
4
5
6

N/A
LC0018
LC0019
LC0020
LC0021
LC0022
LC0023

7

LC0024

8

LC0025

9

LC0026

A
B
C
F
G
H
K

LC0142
LC0101
LC0043
LC0102
LC0047
LC0048
LC0147

M

LC0051

None
On-Board Dust Cover
On-Board Clamp Down
On-Board Vacuum De-gas
On-Board Agitate 120VAC 50/60 Hz
On-Board Agitate 240VAC 50/60 Hz
On-Board Agitate 120 VAC 50/60 Hz
and De-gas
On-Board Agitate 240 VAC 50/60 Hz
and De-gas
On-Board 120VAC 50/60 Hz, De-gas
and Fill-Port
On-Board 240 VAC 50/60 Hz, De-gas
and Fill-Port
Off-Board Clamp Down - 30L
Off-Board Clamp Down - 60L
Off-Board Vacuum De-gas - 30L
Off-Board Vacuum De-gas - 60L
Off-Board Electric Agitator - 30L
Off-Board Electric Agitator - 60L
Off-Board Vacuum De-gas, Pneumatic Agitator, Fill Port, Slinger - 60 L
Off-Board Vacuum De-gas, Electric
Agitator, Fill Port, Slinger - 30 L

9

Product Configurator

R

LC0052

Off-Board Vacuum De-gas, Electric
Agitator, Fill Port, Slinger - 60 L
On-Board, Pneumatic Agitate
On-Board, Pneumatic Agitate, De-gas
On-Board, Pneumatic Agitate, De-gas,
Fill Port
Off-Board Pneumatic Agitator - 30 L
Off-Board Pneumatic Agitator - 60 L
Off-Board Vacuum De-gas, Pneumatic Agitator, Fill Port, Slinger - 30 L

S
T
U

LC0130
LC0131
LC0132

V
W
Z

LC0142
LC0143
LC0146

Code T

Part

Tank Level Sensors

N
2

N/A
LC0278

3

LC0279

4

LC0282

5

LC0281

6

LC0280

7

LC0283

9

LC0284

A

LC0287

B

LC0286

C

LC0289

D

LC0285

E

LC0288

G

N/A

None
Polyethylene Tanks - Low Level Sensors Only
Two 7.5 L Stainless Steel Tanks - Low
Level Sensors Only
Two 30 L or 60 L Stainless Steel Tanks
- Low Level Sensors Only
7.5 L Stainless Steel - Low Level Sensors Only, and 30 L or 60 L Stainless
Steel - Low Level Sensors Only
Accumulator Sensors, and 7.5 L Low
Level Sensors
Accumulator Sensors, and 30 L or
60 L Low Level Sensors
Two 7.5 L Stainless Steel Tanks - High
and Low Level Sensors with Refill
Logic
Two 30 L or 60 L Stainless Steel Tanks
- High and Low Level Sensors with
Refill Logic
7.5 L Stainless Steel - Low Level Sensors, and
30 L or 60 L Stainless Steel - High and
Low Level Sensors with Refill Logic
7.5 L Stainless Steel - High and Low
Level Sensors with Refill Logic, and
30 L or 60 L Stainless Steel - High and
Low Level Sensors with Refill Logic
Accumulator Sensors, and 7.5 L High
and Low Level Sensors
Accumulator Sensors, and 30 L or
60 L High and Low Level Sensors
Two Sets of Accumulator Sensors

10

Code U

Part

N
C
D

N/A
LC0250
LC0251

E

LC0252

F

LC0253

Code V

Part

N
2
3

N/A
LC0103
LC0247

Heat Zone Controller
None
1 Tank or 1 Hose
2 Tanks, 1 Tank and 1 Hose, or 2
Hoses
2 Tanks and 1 Hose, or 1 Tank and 2
Hoses
2 Tanks and 2 Hoses
Off-Board Tank Stands
None
PR70 Tank Stand
PR70v Tank Stand

312760S

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where
applicable.

WARNING
ELECTRIC SHOCK HAZARD
Improper grounding, setup, or usage of the system can cause electric shock.
• Turn off and disconnect power cord before servicing equipment.
• Use only grounded electrical outlets.
• Use only 3-wire extension cords.
• Ensure ground prongs are intact on power and extension cords.
• Do not expose to rain. Store indoors.
SKIN INJECTION HAZARD
High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may
look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
• Do not point dispense valve at anyone or at any part of the body.
• Do not put your hand over the end of the dispense nozzle.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
• Read MSDS’s to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
• Always wear impervious gloves when spraying or cleaning equipment.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection

312760S

11

Warnings

WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic
drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
• Ground all equipment in the work area. See Grounding instructions.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS forms from distributor or retailer.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe
burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.

12

312760S

Warnings

312760S

13

Grounding

Grounding

5. Press the system air pressure relief switch down to
stop air supply and to vent air pressure in the
machine. It is the yellow tab at the left, rear of the
machine. The hole in the tab should be visible.
6. If necessary, run a lock through the hole to lock the
tab in place. This prevents the system air pressure
from being inadvertently enabled.

This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current. This product is equipped with a cord having a
grounding wire with an appropriate grounding plug. The
plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Improper installation of the grounding plug is able to
result in a risk of electric shock. When repair or replacement of the cord or plug is required, do not connect the
grounding wire to either flat blade terminal. The wire
with insulation having an outer surface that is green with
or without yellow stripes is the grounding wire. Do not
modify the plug provided; if it does not fit the outlet, have
the proper outlet installed by a qualified electrician. Only
connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this
product.

Pressure Relief
Procedure

Models with Standard Display
Module

With the machine in an idle state:
1. If the machine pistons are not fully retracted, retract
the pistons by pressing
in the M1 screen. See
manual 3A0429 for more information.
2. Manually open the dispense valve by pressing the
third M1 soft key until the “ ” ICON is shown in the
Current DV field. See manual 3A0429 for more information.
3. Press the system air pressure relief switch down to
stop air supply and to vent air pressure in the
machine. It is the yellow tab at the left, rear of the
machine. The hole in the tab should be visible.

Models with Advanced Display
Module

4. If necessary, run a lock through the hole to lock the
tab in place. This prevents the system air pressure
from being inadvertently enabled.

Shutdown
1. Place a waste container below the dispense valve.
2. Navigate to the Manual screen.
3. Press the Open Dispense Valve button on the Manual screen to relieve chemical pressure.

If the machine is to remain idle for an extended period of
time, perform the following steps.
1. Place a waste container below the dispense valve.

4. Press the Machine Disable Mode button (

14

).

2. If installed, remove static mixer from the end of the
dispense valve.

312760S

Shutdown

3. Place a container below the dispense valve and
activate a small shot to flush mixed material out of
the valve.
4. Relieve pressure. See Pressure Relief Procedure.
5. With a clean rag and cotton swabs, clean the end of
the dispense valve.
6. Install nightcap on the dispense valve.

312760S

15

Troubleshooting

Troubleshooting

Before starting any troubleshooting procedures, perform
the following procedure.

3. Allow the machine to cool if the machine has a heat
control option.

1. Relieve pressure. See Pressure Relief Procedure,
page 14.

Try the recommended solutions in the order given for
each problem to avoid unnecessary repairs. Verify all
circuit breakers, switches, and controls are properly set
and wiring is correct.

2. Disconnect AC power from the machine.
Problem
Display Module completely dark

No or incorrect amount of material
dispensed from either side.

Piston stalled

Significant material leaking from
pump rear seal

16

Cause

Solution

No power

Verify rear AC Power switch is ON.

Fuse blown

Replace machine fuses.

Loose connection

Tighten 5-pin cable on Display Module.

Bad display module

Replace Display Module.

Ball valve closed (if installed)

Open tank ball valve.

Tank empty

Fill tank with material.

Tank clogged

Verify no obstruction in the tank.

Air in material

Prime the machine until the air is
removed.

Check valve malfunction

Remove; clean or replace check
valve.

Piston worn or broken

Remove and replace piston if worn.

Input air reduced or removed

Reconnect input air line to machine.
Increase air pressure regulator
adjustment.

Mixer blocked

Replace static mixer.
Incorporate purge timer or decrease
purge timer delay to prevent mixer
blockage.

Open Dispense Valve (ODV) adjustment too late

Readjust the ODV setting to occur
sooner.

Blocked check valve

Remove check valve; clean and
replace.

Air cylinder failure

Remove air cylinder and reinstall air
cylinder parts as necessary.

Pump shaft worn

Remove pump shaft assembly, and
reinstall rear pump rebuilt kit.

312760S

Troubleshooting

Problem

Cause

Solution

Material dispensed not correct weight Specific gravity of one or more of the Recalibrate machine.
two materials has changed since calibration

Machine dispensing off ratio

Pumps drawing material back from
valve hose

312760S

Machine air pressure has changed
since calibration.

Readjust air pressure regulator to
value used when machine was calibrated, or recalibrate machine.

Not enough material in one or more
tanks

Check tank levels; fill and prime as
necessary.

Mixer has slight obstruction

Replace static mixer. Prime machine.

Check valve malfunction

Remove check valve; clean or
replace as necessary.

Piston worn or broken

Replace piston.

One tank is empty

Check tank levels. Add material if
necessary.

Tank ball valve closed

Open tank ball valve. Prime machine.

Machine out of phase

Rephase machine.

Check valve malfunction

Remove check valve; clean or
replace as necessary.

Piston worn or broken

Replace piston.

Check valve stuck open

Remove check valve, clean or
replace as necessary.

17

Troubleshooting

Error Codes
(Advanced Display Module)
Code-Class-Event
Shown on Errors Screen

Description

050X-A-Improper System Cal

Improper Calibration

5

06CX-A-Invalid Key Token

No or Invalid Key Token

4

A401-A-Over Current Z1

Heater Over Current, Zone #1

7

A402-A-Over Current Z2

Heater Over Current, Zone #2

7

A403-A-Over Current Z3

Heater Over Current, Zone #3

7

A404-A-Over Current Z4

Heater Over Current, Zone #4

7

A4C1-A-Fan Over Current Z1

High Relay 2 Current, Zone #1

7

A4C2-A-Fan Over Current Z2

High Relay 2 Current, Zone #2

7

A4C3-A-Fan Over Current Z3

High Relay 2 Current, Zone #3

7

A4C4-A-Fan Over Current Z4

High Relay 2 Current, Zone #4

7

A701-A-Heater Fault Z1

Unexpected Heater Current, Zone #1

7

A702-A-Heater Fault Z2

Unexpected Heater Current, Zone #2

7

A703-A-Heater Fault Z3

Unexpected Heater Current, Zone #3

7

A704-A-Heater Fault Z4

Unexpected Heater Current, Zone #4

7

A7C1-A-Fan Output Fault Z1

Unexpected Relay 2 Current, Zone #1

7

A7C2-A-Fan Output Fault Z2

Unexpected Relay 2 Current, Zone #2

7

A7C3-A-Fan Output Fault Z3

Unexpected Relay 2 Current, Zone #3

7

A7C4-A-Fan Output Fault Z4

Unexpected Relay 2 Current, Zone #4

7

B10X-A-Small Shot Request

Less Than Minimum Shot Requested

5

CAC1-A-Comm. Error FCM 1

Communication Error, FCM3 #1

2

CAC1-A-Comm. Error FCM2

Communication Error, FCM3 #2

3

CAC1-A-Comm. Error Heat Z1

Communication Error, Heat Zone #1

1

CAC1-A-Comm. Error Heat Z2

Communication Error, Heat Zone #2

1

CAC1-A-Comm. Error Heat Z3

Communication Error, Heat Zone #3

1

CAC1-A-Comm. Error Heat Z4

Communication Error, Heat Zone #4

1

DEFX-A-Piston Timeout

Piston Stroke Timeout

5

DJ0X-D-Linear Sensor Fault

Bad Linear Position Sensor

6

F2A-Low Flow A Side

Low A Side Fluid Flow, relative to calibration and user-input allowable variance.

6

18

System
Behavior Ref

312760S

Troubleshooting

Code-Class-Event
Shown on Errors Screen

Description

System
Behavior Ref

F2B-Low Flow B Side

Low B Side Fluid Flow, relative to calibration and user-input allowable variance.

6

F2FX-D-Delta Velocity Minus

Delta Velocity Minus

6

F3FX-D-Delta Velocity Plus

Delta Velocity Plus

6

F6A-Flow Meter A Problem

Flow Meter A Problem, or bad connection
between Fluid Control Module and Flow
Meter A

6

F6B-Flow Meter B Problem

Flow Meter B Problem, or bad connection
between Fluid Control Module and Flow
Meter B

6

L2AX-D-Low Level Tank A

Low Material Level, Tank A

6

L2BX-D-Low Level Tank B

Low Material Level, Tank B

6

L2FX-D-Low Level Tank A/B

Low Material Level, Both Tanks

6

L8AX-D-Refill Timeout A

Auto Refill Failed, A Side

6

L8AX-D-Refill Timeout B

Auto Refill Failed, B Side

6

P2AX-D-Low Pressure A

A Side Low Pressure, relative to calibration and user-input allowable variance.

6

P2BX-D-Low Pressure B

B Side Low Pressure, relative to calibration and user-input allowable variance.

6

P3AX-D-High Pressure A

A Side High Pressure, relative to calibration and user-input allowable variance.

6

P3BX-D-High Pressure B

B Side High Pressure, relative to calibration and user-input allowable variance.

6

P6AX-D-Pressure Fault A

Problem with A Side Piston Pressure
Transducer or Transducer Connection

6

P6BX-D-Pressure Fault B

Problem with B Side Piston Pressure
Transducer or Transducer Connection

6

P6DX-D-Pressure Fault A/B

Problem with A and B Side Piston Pressure Transducer or Transducer Connection

6

P7DX-D-Out of Phase

Machine Out of Phase, relative to calibration and user-input allowable variance.

6

R2-A:B Ratio Low

A:B Ratio is low, relative to calibration and
user-input allowable variance.

6

R3-A:B Ratio High

A:B Ratio is high, relative to calibration
and user-input allowable variance.

6

T201-D-Low Material Temp Z1

Material Below Temperature, Zone #1

8

T202-D-Low Material Temp Z2

Material Below Temperature, Zone #2

8

312760S

19

Troubleshooting

Code-Class-Event
Shown on Errors Screen

Description

T203-D-Low Material Temp Z3

Material Below Temperature, Zone #3

8

T204-D-Low Material Temp Z4

Material Below Temperature, Zone #4

8

T401-A-High Material Temp Z1

Material Over Temperature, Zone #1

7

T402-A-High Material Temp Z2

Material Over Temperature, Zone #2

7

T403-A-High Material Temp Z3

Material Over Temperature, Zone #3

7

T404-A-High Material Temp Z4

Material Over Temperature, Zone #4

7

T4C1-A-Blanket Over Temp Z1

Blanket Over Temperature, Zone #1

7

T4C2-A-Blanket Over Temp Z2

Blanket Over Temperature, Zone #2

7

T4C3-A-Blanket Over Temp Z3

Blanket Over Temperature, Zone #3

7

T4C4-A-Blanket Over Temp Z4

Blanket Over Temperature, Zone #4

7

T601-A-Material RTD Fault Z1

Material RTD Fault, Zone #1

7

T602-A-Material RTD Fault Z2

Material RTD Fault, Zone #2

7

T603-A-Material RTD Fault Z3

Material RTD Fault, Zone #3

7

T604-A-Material RTD Fault Z4

Material RTD Fault, Zone #4

7

T6C1-A-Blanket RTD Fault Z1

Blanket RTD Fault, Zone #1

7

T6C2-A-Blanket RTD Fault Z2

Blanket RTD Fault, Zone #2

7

T6C3-A-Blanket RTD Fault Z3

Blanket RTD Fault, Zone #3

7

T6C4-A-Blanket RTD Fault Z4

Blanket RTD Fault, Zone #4

7

T801-A-No Heat Z1

No Temperature Rise, Zone #1

7

T802-A-No Heat Z2

No Temperature Rise, Zone #2

7

T803-A-No Heat Z3

No Temperature Rise, Zone #3

7

T804-A-No Heat Z4

No Temperature Rise, Zone #4

7

T901-A-Temp Switch Cutoff Z1

Over Temp Switch Open, Zone #1

7

T902-A-Temp Switch Cutoff Z2

Over Temp Switch Open, Zone #2

7

T903-A-Temp Switch Cutoff Z3

Over Temp Switch Open, Zone #3

7

T904-A-Temp Switch Cutoff Z4

Over Temp Switch Open, Zone #4

7

T9C1-A-Control Shutdown Z1

PCB Over Temperature, Zone #1

7

T9C2-A-Control Shutdown Z2

PCB Over Temperature, Zone #2

7

T9C3-A-Control Shutdown Z3

PCB Over Temperature, Zone #3

7

T9C4-A-Control Shutdown Z4

PCB Over Temperature, Zone #4

7

WM01-A-Current Fault Z1

High Relay 1 Current, Zone #1

7

20

System
Behavior Ref

312760S

Troubleshooting

Code-Class-Event
Shown on Errors Screen

Description

System
Behavior Ref

WM02-A-Current Fault Z2

High Relay 1 Current, Zone #2

7

WM03-A-Current Fault Z3

High Relay 1 Current, Zone #3

7

WM04-A-Current Fault Z4

High Relay 1 Current, Zone #4

7

WMC1-A-Control Fault Z1

Unexpected Relay 1 Current, Zone #1

7

WMC2-A-Control Fault Z2

Unexpected Relay 1 Current, Zone #2

7

WMC3-A-Control Fault Z3

Unexpected Relay 1 Current, Zone #3

7

WMC4-A-Control Fault Z4

Unexpected Relay 1 Current, Zone #4

7

System Behavior Descriptions
NOTE: System behavior descriptions apply only to
Advanced Display Module errors.
System
Behavior
Reference

System Behavior Description
When this error is generated, a pop-up with the error-code will be shown until it is acknowledged by

1

pressing the Enter button (
). The heat control will be turned off, any auto-sequencing in progress
will be stopped, and the foot switch will be disabled until the error-code is acknowledged. When the
error condition is cleared, the heat control may be turned back on from the Home screen. This error
will not disable purge or recirculation operation.
When this error is generated, a pop-up with the error-code will be shown until it is acknowledged by

2

pressing the Enter button (
). All physical machine operation will be disabled until the error condition is corrected. The display module can still be used but all machine commands sent will be ignored.
When this error is generated, a pop-up with the error-code will be shown until it is acknowledged by

3

pressing the Enter button (
). Any auto-sequencing in progress will be stopped and the foot
switch will be disabled until the error-code is acknowledged. This error will not disable purge or recirculation operation. All features dependent on Fluid Control Module #2 will be disabled until the error
condition is corrected.

4

When this error is generated, a pop-up with the error-code will be shown continuously until the error
condition is corrected. The machine and display module are completely disabled until the error condition is corrected.

5

When this error is generated, a pop-up with the error-code will be shown. Any auto-sequencing, purge
timer or recirculation timer operation in progress will be stopped and the foot switch will be disabled
until the error-condition is cleared. The error-code pop-up will be shown until the error condition is
cleared. When the error condition is cleared, all options may be turned back on.

312760S

21

Troubleshooting

System
Behavior
Reference

System Behavior Description
When this error is generated, a pop-up with the error-code will be shown until it is acknowledged by

6

pressing the Enter button (
). Any auto-sequencing in progress will be stopped, and the foot
switch will be disabled until the error-code is acknowledged. Once the error-code pop-up is acknowledged, the machine will return to normal operation The error will be shown in the Errors screen until
the condition is cleared. The error-code pop-up will not reappear unless the error condition is cleared
and then reappears. This error will not disable purge or recirculation operation.
When this error is generated, a pop-up with the error-code will be shown until it is acknowledged by

7

pressing the Enter button (
). All heat options will be turned off, any auto-sequencing in progress
will be stopped, and the foot switch will be disabled until the error-code is acknowledged. When the
error condition is cleared, the heat control may be turned back on from the Home screen. This error
will not disable purge or recirculation operation.
When this error is generated, a pop-up with the error-code will be shown until it is acknowledged by

8

22

pressing the Enter button (
). All heat options will remain on, any auto-sequencing in progress
will be stopped, and the foot switch will be disabled until the error-code is acknowledged. This error
will not disable purge or recirculation operation.

312760S

Troubleshooting

Error Codes
(Standard Display Module)
When the machine is operating and a fault is detected, it
will report the condition by generating an error code.
Error codes are typically generated when the machine is
idle after dispensing a shot.
When error codes are generated, a screen will be displayed which contains an animation sequence, the error
code number and an ICON symbol representing the
condition detected. The HMI will also output an error
code tone sequence. The tone sequence cannot be disabled.

Key:
A Error Code Animation Field
B Error Code Number Field
D Error Code ICON
E Error Code Acknowledgement ICON
When an error code is generated, the user will need to
acknowledge the condition by pressing the soft key
under the

ICON.

After the user activates the
key, the error number
shown in FIG. 1, will be displayed on the bottom left
hand corner of the Run screen, while the condition is still
present.

When errors are generated, the machine will automatically be disabled and remain in an idle state until the
user acknowledges the condition. Any active purge timer
present prior to error code generation will be suspended, and will need re-started by requesting a shot
after the error is acknowledged.
The following typical screen is generated when an error
code is generated:

FIG. 2: Typical Run Screen with Active Error Code
The example E12 number on the main run screen will
remain on the run screen as long as the error condition
exists. If the problem is corrected the example E12 number will be removed.

FIG. 1: Typical Error Code Screen

If more than 1 error code condition exists for the
machine, the corresponding “EXX” numbers will be
listed on the bottom left corner, separated by commas.

Error
Code

Title

Cause, Details

E11

Stuck Key Error

E12

Communication
Error

A key on membrane has been active (pressed) for > 30 seconds
continuously. Replace the HMI. This error code does not require user
acknowledgment and will clear itself automatically if the condition is
removed.
The Display module has lost communication with the Fluid Control Module.
Material dispensing will be disabled if this condition exists. Check
communication cables between the 2 electronic components, or check the
HMI and/or the Fluid Control Module.

E13

No or Invalid Run
Token Error

E21

Piston Stroke
Time-out Error

312760S

ICON

This error will be regenerated continuously while the condition exists.
The Run Token in the FCM is missing (not installed), or does not have the
correct data.
A piston stroke action has taken > 55 seconds. Typically caused by no/too
little air pressure to the machine or a mechanical interference with the
piston has occurred. Check machine input line pressure.

23

Troubleshooting

Error
Code
E23

E24

E25

E26

E27

E28

E29

E50

24

Title

Cause, Details

Less than
Minimum Shot
Requested Error
Improper
Calibration Error

User has requested a shot < the minimum allowable size entered during
calibration. (< 15% of stoke, N/A in Operator Mode).

Delta Velocity
(“V”) Minus Error

Delta Velocity
(“V”) Plus Error

Low Material
Level, Tank A
Alarm or Error
Low Material
Level, Tank B
Alarm or Error

ICON

The calibration done on the machine is invalid, so the requested shot
cannot be executed. For instance, a Large Stroke Calibration Shot mass
which is less than the Short Stroke Calibration Shot mass (C4 screen) will
create this error code. If the wiring to the linear position transducer is
reversed this error will appear. If invalid piston positions are calibrated into
the machine (C1 screen) this error will appear.
The piston velocity is slower than the calibration velocity measured, by the
percentage amount selected by the user (20%, 40% or 60%). If the user
selects 0%, this monitoring or alarm feature is disabled.
If generated, shot size accuracy may be degraded. Typically the problem is
created when the machine pressure regulator is adjusted to different value
from when the machine was calibrated. Another less likely cause could be a
mechanical failure with dispensing (worn piston, etc.). This error will not be
generated for a purge shot or when the machine is in Operator mode.
The piston velocity is faster than the calibration velocity measured, by the
percentage amount selected by the user (20%, 40% or 60%). If the user
selects 0%, this monitoring or alarm feature is disabled.
If generated, shot size accuracy may be degraded. Typically the problem is
created when the machine pressure regulator is adjusted to different value
from when the machine was calibrated. Another less likely cause could be a
mechanical failure with dispensing (worn piston, etc.). This error will not be
generated for a purge shot, or when the machine is in Operator mode.
Tank A is low (only generated if tank sensing is enabled). Fill tank A with
material.
Tank level errors will be generated after every shot if the condition still
exists.
Tank B is low (only generated if tank sensing is enabled). Fill tank B with
material.

Tank level errors will be generated after every shot if the condition still
exists.
Both tanks are low (only generated if tank sensing is enabled). Fill both
Low Material
Level, Both Tanks tanks with material.
Alarm or Error
Tank level errors will be generated after every shot if the condition still
exists.
Bad Linear
There is a fault with the linear position sensor. Check wiring or replace.
Position Sensor

312760S

Electrical Schematics

Electrical Schematics
A
B
C

NOTE: Fluid Control Module #2
sections apply only to models with
Advanced Display module

D
E
F

See FIG. 6

G
H

J
K
L
M

See FIG. 6

See FIG. 6
N
P
R

S
T
U
V
W
X
FIG. 3: Electrical Schematic - Page 1

312760S

25

Electrical Schematics

A
B
C

D
E
F

G
H

J
K
L
M

N
P
R

S
T
U
V
W
X
FIG. 4: Electrical Schematic - Page 2
26

312760S

Electrical Schematics

FIG. 6
FIG. 6
FIG. 6

FIG. 6

FIG. 5: Electrical Schematic - Page 3

312760S

27

Electrical Schematics

NOTE: See PR70 operation manual for Optional External Control Interface instructions.

Customer Supplied
Dry Contact/Relay

2

2
3

1
5
4

NOTE: Connector #2 is for use
with systems with an Advanced
Display Module only.

Brown
Gray
Black
Blue
White

SHOT SEL - BIT 0
SHOT SEL - BIT 3
Not Used
COMMON
SHOT SEL - BIT 1

NOTE: View shown is looking at
pins on end of cable.
Customer Supplied
Dry Contact/Relay

1
NOTE: Connector #1 is for use
with all systems.

2
3

1
5
4

NOTE: View shown is looking at
pins on end of cable.

Brown
Gray
Black

SHOT REQUEST - INPUT
FAULT OUTPUT
INTERRUPT - CAN - REQ - INPUT

Blue
White

COMMON
READY - OUTPUT

+24 VDC

+24 VDC

FIG. 6: Electrical Schematic - Page 4

28

312760S

Repair

Repair
HydraCheck Kit Installation
200d
1

200b

200a

200c

203

AA
1

ti12437a

Torque to 85 in-lb (9.6 N•m).

FIG. 7: HydraCheck Installation - Variable Ratio Base

420
100d
100b
103
104

ti12436a

FIG. 8: HydraCheck Installation - Fixed Ratio Base

312760S

29

Repair

The following procedure is the same for Fixed and
Variable Ratio bases, except where noted. See FIG.
7 and FIG. 8 for part references. See Kits on
page 80 for kit numbers.
NOTE: The HydraCheck kit is intended to be used with
low viscosity materials to minimize splashing. It is not
intended to be used as a timer or flow control device.
Prepare Machine for Kit Installation
1. Navigate to the Manual screen.
2. Press the Retract Piston Command button.
3. Relieve system pressure. See Pressure Relief Procedure on page 14.

Install Adjustment Screw/Cap

9. On Variable Ratio models, loosely install hex
nut (200d) and adjustment screw (200c) onto the
variable ratio drive block (AA).
On Fixed Ratio models, loosely install hex
nut (100b) and adjustment cap (100d) onto the air
cylinder shaft (420).
Adjust the Adjustment Screw/Cap

4. Remove shroud screws (2202, 2409). See FIG. 17
on page 44 and FIG. 21 on page 49.
5. Remove the shroud (117, 214). See FIG. 16 on
page 42 and FIG. 21 on page 49.
Install HydraCheck Shock

Be sure that system pressure is relieved and disabled before proceeding.

6. Install shock absorber (200a) through the opening in
the pump sub-assembly (203) with the groove for
the snap ring on the back of the pump assembly.
The shock absorber can be inserted through the
front or the back of the pump sub-assembly.

10. Push the drive block (104, AA) forward until resistance is felt when it engages the cylinder. Make sure
the resistance is not due to shock absorber (200a)
contact with the adjustment screw (200c) or adjustment cap (100d).
11. Adjust the adjustment screw or adjustment cap until
it contacts the shock absorber.
12. On Variable Ratio models, hold the adjustment
screw (200c) in place and tighten the hex nut (200d)
against the drive block (AA).
On Fixed Ratio models, hold the adjustment
cap (100d) in place and tighten the hex nut (100b)
against the adjustment cap.
Prepare Machine for Operation

7. Install shock snap ring (included with shock, not
shown) onto the shock absorber (200a) in the
groove farthest from the pump sub-assembly.

13. Lift the system air pressure relief switch to enable
system pressure. It is the yellow tab at the left, rear
of the machine.

8. Install set screw (200b) and torque to 85 in-lb
(9.6 N•m).

Adjust Shock Resistance
14. Execute a shot to see how the shock absorber
affects the speed of the drive block (104, AA).
15. The shock absorber has a numeric scale on one
side. Rotate the knob with the scale to a higher
value for more resistance. Rotate the knob to a
lower value for less resistance.
16. Repeat these steps until the desired resistance is
achieved.

30

312760S

Repair

Air Cylinder Kit Installation
420
401

411

4
4

405

417

412

403

419
406
412

413
416

415
422

411 4

412
418

407
1

414

409

412

2

414
415
ti12490a

410
1

Torque to 41 in-lb (4.6 N•m).

2

Torque to 350 in-lb (39.5 N•m).

3

Torque to 100 ft-lb (135 N•m).

4

Coat all sliding surfaces with lubricant, part 115982.

5

Apply sealant tape to npt fittings.

See Kits on page 80 for kit numbers.

Prepare Machine for Kit Installation
1. Relieve pressure. See Pressure Relief Procedure,
page 14.
2. Shut down the machine. See Shutdown, page 14.
3. Disconnect the pressurized air input hose.
4. Remove shroud screws (2202, 2409). See FIG. 17
on page 44 and FIG. 21 on page 49.
5. Remove the shroud (117, 214). See FIG. 16 on
page 42 and FIG. 21 on page 49.

312760S

404

408

402

Disassemble the Air Cylinder
6. Remove the incoming power bracket (110) from the
machine by removing the two attachment
screws (109). See FIG. 15 on page 41.
7. Remove the two solenoid valves (407, 408) from the
cylinder blind end block (418) by removing the three
socket head cap screws (402).
8. Use an open-end wrench to remove all hex
nuts (103, 100b, 100d) connecting the piston rod to
the drive block. See FIG. 15 on page 41.
9. Remove the four screws (108) that attach the cylinder rod end block (417) to the frame. See FIG. 15 on
page 41. Access the screws through the four holes

31

Repair

in the blind end block (418) using a long allen
wrench.
10. Partially remove the air cylinder by pulling on the
cylinder from the back of the machine until the air
lines at the elbow fittings can be seen.

them. Then torque the bolts to 350 in-lb (39.5 N•m)
in a crisscross pattern.

3
1

11. With the cylinder partially removed, disconnect the
airlines at the air cylinder elbow fittings.
12. Finish removing air cylinder.
13. On a bench, disassemble the air cylinder by removing the four long screws (404) that connect the two
cylinder blocks.
Clean and Inspect the Parts

2
4
22. Insert the cylinder rod (420) through the hole in the
rod end cylinder block (417) and base frame.

14. Inspect the cylinder tube (416) and piston (419) for
scratches. Replace if necessary.

23. Before the cylinder is completely in place, reconnect
the airlines to the cylinder block elbows fittings. Verify the correct airlines are connected.

15. Using a clean dry cloth, remove any grease from the
inside of the tube (416), the outside of the
piston (419), and the cylinder rod (420).

24. Reinstall the four screws (108) that attach the cylinder rod end block (417) to the frame. See FIG. 15 on
page 41.

16. Remove the two cylinder block o-rings (411) from
the blocks (417, 418) and replace.

25. Reinstall the hex nuts (103, 100b, 100d) to the cylinder rod (420) and torque to 100 ft-lb (135 N•m). See
FIG. 15 on page 41.

17. Remove the piston o-ring (403) and replace.
18. Remove the cylinder rod (420) from the rod end
block (417).

26. Install the three screws (402) that attach the solenoid valves (407, 408) to the blind end block (418).
Torque to 41 in-lb (4.6 N•m).

19. Remove the rod o-ring (401) from the rod end
block (417) and replace.

Prepare Machine for Operation

20. Liberally apply high temperature lubricant grease
(part 115982) to the inside of the tube (416), the
outside of the piston (419), all the o-rings, and the
cylinder rod (420).
Re-Assemble the Air Cylinder

27. Reattach the incoming power bracket (110) by reinstalling the two attachment screws (109). See FIG.
15 on page 41.
28. Reconnect pressurized air input hose.
29. Operate the machine and ensure there are no air
leaks are found.

NOTICE
In the following step, the long screws must be tightened in a crisscross pattern. Failure to do so may
result in air cylinder damage.
21. Reinstall the four long screws (404) that attach the
two drive blocks (417, 418) by finger-tightening

32

30. Install the shroud (117, 214). See FIG. 20 on page
47 and FIG. 21 on page 49.
31. Install shroud screws (2202, 2409). See FIG. 17 on
page 44 and FIG. 21 on page 49.
32. Calibrate the machine. See the appropriate operation manual referenced at the beginning of this manual for procedure.

312760S

Repair

Rear Pump Rebuild Kit Installation
See Kits on page 80 for kit numbers.

The pump shaft is installed with Krytox. Contact with
Krytox can lead to flu-like symptoms. The MSDS for
this material is available upon request.
513

506

514
507

2

508

511

501
504
512
503
505

1

502

3

3

510

ti12491a

509
1

Torque to 350 in-lb (39.5 N•m).

2

Lube shaft with krytox grease prior to insertion into bearing.

3

Shaft seal (503) must be installed with open side facing the washer (512).

FIG. 9
Prepare Machine for Kit Installation
1. Drain the pump.
• If ball valves are installed, close the ball
valves then take several shots.
• If ball valves are not installed, empty the
tanks. Perform shots repeatedly until no material comes out of the dispense valve.

312760S

2. Relieve pressure. See Pressure Relief Procedure,
page 14.
3. Shut down the machine. See Shutdown, page 14.
4. Disconnect the pressurized air input hose.
5. Remove shroud screws (2202, 2409). See FIG. 17
on page 44 and FIG. 21 on page 49.

33

Repair

6. Remove the shroud (117, 214). See FIG. 16 on
page 42 and FIG. 21 on page 49.
Disassemble the Rear Pump Assembly
7. Disconnect the pump shaft (511) from the drive
block.
a. Loosen the shaft locking nut (502).

block. This will prevent the threads from damaging
the seal (503).
17. Slide the pump shaft through the hole in the bearing
housing.
18. Align the bearing housing in position next to the
pump housing.
19. Install the pump collar over the bearing housing.

b.

Hold the drive block alignment rod (2302, 2419)
stationary with a wrench. See FIG. 18 on page
45 and FIG. 22 on page 50.

20. Attach the pump housing using the two
screws (505) and torque to 350 in-lb (39.5 N•m).
21. Remove the masking tape from pump shaft (511).

c.

Turn the pump shaft (511) with a wrench.

d. Manually push the pump shaft (511) forward to
to separate the shaft from the drive block.
8. Remove the shaft lock nut (502).
9. Remove the two screws (505) that hold the pump
collar in place.
10. Remove the pump collar (509) from the pump
housing (507).

22. Install the pump shaft lock nut (502) onto the pump
shaft (511).
23. Connect the pump shaft to the drive block alignment
rod (2302, 2419). See FIG. 18 on page 45 and FIG.
22 on page 50. Screw the shaft completely into the
drive block.
24. Tighten the lock nut (502)
Prepare for Operation
25. Open the tank ball valves if installed.

11. Slide the pump bearing housing (510) away from
the pump housing (507) to remove.

26. Fill tanks.

12. Remove rear pump components from the pump
bearing housing (510).

27. Perform several shots to fill the pump with new
material.

Clean and Inspect the Parts

28. Calibrate and phase the machine. See the appropriate operation manual referenced at the beginning of
this manual for procedure.

13. Using a clean dry cloth, remove any existing grease
from the bearing housing.
14. Apply new high temperature grease lubricant
(part 115982) to the inside of the pump bearing
housing (510), and the new rebuild components.
Assemble the Rear Pump Assembly
15. Install the new rebuild kit components into the bearing housing.
NOTICE
Be careful when installing the seal (503). Ensure
there is masking tape on the threads of the piston rod
and that the open side of the seal faces the piston rod
when it slides onto the rod.
16. Apply one layer of thin masking tape over the male
threads of the pump shaft that mates with the drive

34

312760S

Repair

Piston/Cylinder Replacement Kit
Installation

7. Push the drive block (104, AA) forward until pistons
are fully extended. See FIG. 7 and FIG. 8 on
page 29.

See Piston Package on page 60 and Nylon and
UHMW Piston Replacement Kits on page 63 for
kit numbers.

8. Use a wrench to prevent the pump shaft (511) from
rotating and remove the piston screw (605). See
FIG. 9 on page 33.

606
1

601

10. Clean the washers.

606

Install Cylinder

605
602

9. Remove the piston (602) and any front or rear
washers (603) from the pump shaft (511). See FIG.
9 on page 33.

603

11. Install the new piston and any front or rear washers.

604

12. Install the piston screw (605).
ti12438a

1

Tighten the piston screw until the piston stops rotating, then turn the screw an additional 1/4 turn.

The arrow imprinted on the cylinder points
toward the pump outlet.

13. Fully retract the piston.
Prepare Machine for Kit Installation
1. Drain the pump.
• If ball valves are installed, close the ball
valves then take several shots.
• If ball valves are not installed, empty the
tanks. Perform shots repeatedly until no material comes out of the dispense valve.
2. Relieve pressure. See Pressure Relief Procedure,
page 14.

14. Lubricate the new o-rings with high temperature
grease (part 115982).
15. Insert the lubricated o-rings (606) into the grooves
of the pump housing (507) and end caps (508). See
FIG. 9 on page 33.
16. Install the cylinder between the pump housing (507)
and end cap (508). See FIG. 9 on page 33.
17. Secure cylinder in place with the four end cap
screws (506). See FIG. 9 on page 33.

3. Models with ADM: To prevent machine movement,
Prepare Machine for Operation
press the Machine Disable Mode key (
).
Models with SDM: To prevent machine movement,
press the Red button

.

Disassemble Cylinder
4. Remove the four end cap screws (506). See FIG. 9
on page 33.
5. Remove the pump end caps (508). See FIG. 9 on
page 33. Allow the cap to hang by the hose.

18. Open the tank ball valves if installed.
19. Fill tanks.
20. Perform several shots to fill the pump housing (507)
with new material.
21. Calibrate and phase the machine. See the operation
manual referenced at the beginning of this manual
for procedure.

6. Remove the cylinder (601) and o-rings (606) from
the pump housing (507). See FIG. 9 on page 33.

312760S

35

Repair

Check Valve Rebuild Kit
Installation

the female threaded end of the check valve
housing (513).

See Pump Sub-Assembly, LC0112, page 54 for
pump sub-assembly part references. See Kits on
page 80 for kit numbers.
Inner Radius

Outside
Chamfer
2104

10. Install the check valve ball (2101) on top of the
spring (2101).
11. Place the seat (2104) on top of the check valve
ball (2101) with the outside chamfered side of the
seat facing away from the check valve ball.

1

2102

12. Hold both ends of the assembled check valve
assembly and install the check valve into the
unthreaded end of the check valve housing (513)
with the ball end facing out. See FIG. 9 on page 33.

Side of seat with outside chamfer must face away
from ball. Side of seat with inner radius must face the
ball.

13. Apply pressure to the valve to snugly fit the assembled check valve (514) into the check valve
housing (513). Fit the check valve seat (2104) into
the valve guide. See FIG. 9 on page 33.

2101

ti12565a
1

9. Place the new check valve ball guide (2103) on a
bench with the open end up. Install the check valve
spring (2102) into the guide.

2103

FIG. 10: Check Valve Rebuild Kit
Prepare Machine for Kit Installation
1. Relieve pressure. See Pressure Relief Procedure,
page 14.
2. Models with ADM: To prevent machine movement,
press the Machine Disable Mode key (
).
Models with SDM: To prevent machine movement,
press the Red button

.

3. Place a waste container below the dispense valve to
catch any dispensed material.
4. Push the drive block (104, AA) forward until pistons
are fully extended. See FIG. 7 and FIG. 8 on
page 29.

Verify when the assembled check valve (514) and
housing (513) are turned up-side down that the
contents of the check valve stay in place.

14. Use a wrench to insert the new valve and valve
housing into the pump end cap (508).
15. Install the material male hose fitting into the check
valve housing using a wrench.
16. Before operating the machine, activate a few shots
to purge any air present in the material hose lines.
17. Calibrate the machine if necessary. See the appropriate operation manual referenced at the beginning
of this manual for procedure.

5. Move the waste container to below the check
valve (514).
6. Disconnect the male hose fitting from the check
valve housing (513) by loosening the hose from the
housing. See Pump Sub-Assembly, LC0112,
page 54.
7. Remove the check valve housing (513) from the
pump endcap (508) by loosening the housing with a
wrench.
8. Remove the existing check valve (514) from the
housing by inserting a screwdriver or dowel rod into
36

312760S

Repair

Piston Plug Installation

Pressure Transducer Installation
NOTE: The pressure transducers are designed to work
with the hoses available in the PR70 configurator. If they
are used with other hoses, unexpected alarms may
occur.

508

1. Follow steps 1 through 6 of Piston Plug Installation on this page.

1802

2. Remove shield locking screws (2202, 2409) then
remove shield (117, 214).

1801

3. Install hex end of pressure transducer into end
cap (508).
ti12562a

1. Drain the pump.
• If ball valves are installed, close the ball
valves then take several shots.
• If ball valves are not installed, empty the
tanks. Perform shots repeatedly until no material comes out of the dispense valve.
2. Relieve pressure. See Pressure Relief Procedure,
page 14.

4. For A side pressure transducers, install data
cable end of pressure transducer into port #6 of
Fluid Control Module #1. See FIG. 5, page 27.
For B side pressure transducers, install data
cable end of pressure transducer into port #7 of
Fluid Control Module #1. See FIG. 5, page 27.
5. Install shield and shield locking screws.
6. Follow steps 8 through 10 of Piston Plug Installation on this page.

3. Models with ADM: To prevent machine movement,
press the Machine Disable Mode key (
).
Models with SDM: To prevent machine movement,
press the Red button

.

4. Use a wrench to remove the existing piston
plug (1801) from the pump end cap (508).
5. Remove the existing o-ring (1802).
6. Lubricate the new o-ring with a high temperature
grease (part 115982) and install the lubricated
o-ring into the end cap.
7. Install pump plug (1801) into end cap.
8. Open the tank ball valves if installed.
9. Fill tanks.
10. Perform several shots to fill the pump with new
material.

312760S

37

Repair

Flow Meter Installation

9. Install fluid lines into fitting (2003) on top of flow
meter.

1. Drain the pump.
• If ball valves are installed, close the ball
valves then take several shots.
• If ball valves are not installed, empty the
tanks. Perform shots repeatedly until no material comes out of the dispense valve.

10. For side A flow meters, plug flow meter sensor
cable into port #1 on Fluid Control Module #2.
For side B flow meters, plug flow meter sensor
cable into port #2 on Fluid Control Module #2.

2. Relieve pressure. See Pressure Relief Procedure,
page 14.
3. Models with ADM: To prevent machine movement,
press the Machine Disable Mode key (
).
Models with SDM: To prevent machine movement,
press the Red button

11. Open the tank ball valves if installed.
12. Install shield and shield locking screws.
13. Fill tanks.
14. Perform several shots to fill the pump with new
material and to prime the flow meters.

.

4. Remove shield locking screws (2202, 2409) then
remove shield (117, 214).
5. Use a wrench to remove fluid lines from top of pump
end cap (508).
6. Use fittings (2004, 2005) to install flow meter
body (2001) onto end cap (508). See following
image.
2003
2002

2001

2004

2005
508

ti13898a

7. Install remaining fitting (2003) onto top of flow
meter. See preceding image.
8. Install flow meter sensor (2002) onto flow meter
body (2001).

38

312760S

Repair

Fluid Control Module
Replacement

If there is only one fluid control module on the
machine, the module number is 1.
If there are two fluid control modules, the module closest to the air regulator is module number 1
and the other module is number 2.

1. Remove access cover (D).
C

1

A

C

D

ti12334a

B
1

Connection
Reference
(FIG. 12)
1

Module
Number
1

2

1

3
4
1
2
3
4

1
1
2
2
2
2

Connects To
Footswitch or
PLC Interface
Footswitch or
PLC Interface
Tank Low Level Sensor A
Tank Low Level Sensor B
Flow Meter A
Flow Meter B
Tank High Level Sensor A
Tank High Level Sensor B

6. Connect cables to rear of fluid control module. See
FIG. 13 and the following table.

Not visible from current angle.

FIG. 11
2. Remove two screws (C) and FCM (A) from base (B).
3. Mount base (B) to system with four screws. Insert
screws through top of base and tighten to system.
4. Mount FCM (A) on base (B) with two screws (C).
5. Connect cables to front of fluid control module. See
FIG. 12 and the following table.
3
4

ti12336a

6

7

5
FIG. 13: Fluid Control Module Rear Connections
If there is only one fluid control module on the
machine, the module number is 1.
If there are two fluid control modules, the module closest to the air regulator is module number 1
and the other module is number 2.

2
1
ti12337a

FIG. 12: Fluid Control Module Front Connections

Connection
Reference Module
Number
(FIG. 13)
5
1
6
7
5
6
7

312760S

1
1
2
2
2

Connects To
Dispense Valve and
Linear Position Sensor
Pressure Transducer A
Pressure Transducer B
Auto-Fill Valve
Not Used
Not Used

39

Repair

7. If there is only one fluid control module on the
machine, set the rotary switch (S) to 1. See FIG. 14.
If there are two fluid control modules, set the
rotary switch (S) to 1 on the module closest to the
air regulator and set the rotary switch (S) to 2 on the
other module. See FIG. 14.

Fuse Replacement

The rotary switch setting must only be adjusted on
new fluid control modules after installation. The
rotary switch setting indicates the fluid control module number being replaced. The fluid control module uses a 16-position rotary switch.

Fuse Holder

1

ti12563a

S
1

ti12335a

FIG. 14
8. Install access cover (D).

Fuse holder is located between the
power connector and power switch.

1. Remove incoming power cord from machine.
2. Insert a flat-head screw-driver between the fuse
holder and the back of the incoming power bracket
remove machine fuse holder.
3. Remove the blown fuse from the machine fuse
holder.
4. Install new fuse with same rating into the fuse
holder.
5. Install the fuse holder into the Incoming Power
Bracket.

40

312760S

Parts

Parts
See Feed Systems manual for feed system parts.
See Related Manuals on page 3.

Fixed Ratio Base, LC0262, LC0263, LC0264, LC0265
2

105
100d

3

100b

106

103
2

108

3

104

107
1

Torque to 85 in-lb (9.6 N•m).

2

Torque to 350 in-lb (39.5 N•m).

3

Torque to air cylinder shaft
to100 ft-lb (135 N•m).

111

ti12436a

109

110
118

119

1

109
ti12486a

FIG. 15
312760S

41

Parts

Fixed Ratio Base, continued
100c

1

102

2

101

100a

1

Torque to 85 in-lb (9.6 N•m).

2

Torque to 350 in-lb (39.5 N•m).

4

Retaining ring must rest against
pump body.

4

ti12487a

117a

117

120

112

ti12476b

FIG. 16

42

312760S

Parts

Ref Part
100a 120920
100b 120919
100c 111260
100d 15K816
101
102
103
104
105
106

LC0112
120913
120919
LC0107
121166
LC0110
LC0111

107
108
109
110
111
112
114
115
116
117
117a
118
119

LC0290
121167
120885
LC0239
LC0261
255235
* 121597
* 61/2906-BK/11
* 61/2904-BK/11
LC0308
▲15M511
84/0001-6/11
96/0235/98

120
127

255244
* LC0135

*

Description
SHOCK ABSORB, adjustable
(models LC0263 and LC0265 only)
NUT, hex
(models LC0263 and LC0265 only)
SCREW, set, cup point
(models LC0263 and LC0265 only)
CAP, adjustment, Hydracheck
(models LC0263 and LC0265 only)
PUMP, sub-assembly
SCREW
NUT, hex
BLOCK, assembly, drive
SCREW
CYLINDER, air, sub-assembly, 3.0 in.
(models LC0262 and LC0263 only)
CYLINDER, air, sub-assembly, 4.5 in.
(models LC0264 and LC0265 only.)
FRAME, sub, assembly
SCREW
SCREW
BRACKET, incoming power, sub-assy
BRACKET, controls, assembly
BRACKET, mounting, assembly
CABLE, CAN, 90 female / 90 female
TUBE, air, 3/8 in. OD
TUBE, air, 1/4 in. OD
SHIELD, assembly
LABEL, shield
TAG, ID
SCREW, drive, type U, #2 X 3/16 stainless
steel
SWITCH, foot, assembly
MODULE, TOKEN, PR70

Qty
1
1
1
1
1
4
1
1
4
1
1
1
4
6
1
1
1
1
2
2
1
1
1
4
1
1

Not shown.

▲ Replacement Danger and Warning labels, tags, and cards are available at no cost.

312760S

43

Parts

Fixed Ratio Frame Sub-Assembly, LC0290
2205

2206

2204

2202

1

2201

2203

1

2202

2207

ti12572a

1

Apply anti-seize compound (part 073025) to screws.

FIG. 17

Ref
2201
2202
2203
2204
2205
2206
2207

44

Part
120599
120913
15K788
LC0234
120918
120886
96/0507/11

Description
PIN, dowel
SCREW
FRAME, base, machined
SENSOR, assembly
BEARING, linear, slide
SCREW
BUMPER, rubber, 3/8-16 x 0.63

Qty
2
2
1
1
1
4
4

312760S

Parts

Fixed Ratio Drive Block
Assembly, LC0107
2306
3

1

2301

2305
2308

1
1
2

2302

2305

2307
2309

2303
2304

ti12573a

1

Apply grease (part 115982) to all internal parts.

2

Tighten retaining nut until alignment rod (2302) cannot be moved.
Loosen retaining nut until alignment rod can move side-to-side with
no in-and-out movement.

3

Torque to 64 in-lb (7.2 N•m).

FIG. 18

Ref
Part
2301 120891
2302 15K801
2303 15K802
2304 15K805
2305 15K868
2306 ▲ 84/0130-27/11
2307 15T389
2308 120885
2309 15G747

Description
Qty
SCREW, set, socket, cone point
2
ROD, alignment
2
RETAINER, nut
2
BLOCK, drive
1
WASHER, female, male modified, assembly
2
LABEL, warning, pinch point
1
BRACKET, mounting, magnet
1
SCREW
2
MAGNET, linear sensor
1

▲ Replacement Danger and Warning labels, tags, and cards are available at no cost.

312760S

45

Parts

Variable Ratio Base, LC0242, LC0243, LC0244, LC0245
1
2

200c

200b

200d

200a

208

203

209

202

2

3

201
ti12437a

1

Torque to 85 in-lb (9.6 N•m).

2

Torque to 350 in-lb (39.5 N•m).

3

Torque to air cylinder shaft to100 ft-lb (135 N•m).

207

1

205

204

1

210

207
ti12488b

1

Torque to 85 in-lb (9.6 N•m).

FIG. 19

46

312760S

Parts

Variable Ratio Base continued
214a

214

206

ti12475b

FIG. 20
Ref

Part

200a

120920

200b
200c

200d
201
202

203
204
205
206
207
208
209
210
212

Description

SHOCK ABSORB, adjustable
(models LC0243 and LC0245 only)
111260
SCREW, set, cup point
(models LC0243 and LC0245 only)
121589
SCREW, hex head cap, M12 x
1.75, 80 mm long
(models LC0243 and LC0245 only)
107539
NUT, hex
(models LC0243 and LC0245 only)
LC0232
FRAME, sub-assembly
LC0230
CYLINDER, air, 3.0 in. diameter
(models LC0242 and LC0243 only)
LC0231
CYLINDER, air, 4.5 in. diameter
(models LC0244 and LC0245 only)
LC0112
PUMP, sub-assembly
LC0239
BRACKET, incoming power,
sub-assy
LC0240
BRACKET, control, sub-assembly
255244
SWITCH, foot, assembly
120885
SCREW
120913
SCREW
121167
SCREW
16D782
LABEL
61/2904-BK/11 HOSE, 0.160 ID x 0.250 OD, PU,
95 DUR

312760S

Qty

Ref

Part

1

213

1

214
214a
215

61/2906-BK/11 HOSE, 0.245ID x 0.375 OD, PU, 95
DUR
LC0246
SHIELD, assembly
▲15M511
LABEL, shield
* 124002
PROTECTOR, wire, corrugated,
5/8 in. ID
* 124002
PROTECTOR, wire, corrugated,
5/8 in. ID

1

1
1
1
1

*

Description

Qty

Not shown.

▲ Replacement Danger and Warning labels, tags, and
cards are available at no cost.

1
1
1
1
5
4
4
1
1

47

1
1
1
8
5

Parts

48

312760S

Parts

Variable Ratio Frame Sub-Assembly, LC0232
1

2406

2409

2

2430
2409
2404
2404

1

2409

5

2406

2416
5

2417

ti12568a

2436

2427

2415

2405
2401 7
2426
10

2418

Drive Block Rear Parts
1

Torque screws to 140 in-lb (15.8 N•m).

7

Torque to 8 in-lb (0.9 N•m).

2

Torque screws to 350 in-lb (39.5 N•m).

8

3

Torque stud to 780 in-lb (88.1 N•m).

4

Ref 2414 and 2428 must be oriented as
shown.

Tighten retaining nut until alignment rod
(2419) cannot be moved. Then loosen
retaining nut until alignment rod can
move side to side with no in-and-out
movement.

9

Torque to 19 in-lb (2.1 N•m).

5

Lubricate bearing and threaded
surfaces with 115982.

10

Bond 2418 into 2427 using adhesive,
part 071023.

11

Press fit 2403 into 2424.

6

Torque to 35 in-lb (3.9 N•m).

2432

ti12569a

FIG. 21

312760S

49

Parts

Variable Ratio Frame Sub-Assembly continued
2407

2

2424
1

2410
3

5
5
8

2425

3

2414

2419

9

5

2425

2435

2403 11

2413
2421
9

5

5

2413

4
5

2429

2402

2

2434

2412

2421

2420

2403

2411
11

2422
2424

2412

2407

2

Drive Block Front/Side Parts

ti12571a
4

2428
2414 4

2435
2425

3

5

5

2425

2423
3

5

2411

1

Torque screws to 140 in-lb (15.8 N•m).

7

Torque to 8 in-lb (0.9 N•m).

2

Torque screws to 350 in-lb (39.5 N•m).

8

3

Torque stud to 780 in-lb (88.1 N•m).

4

Ref 2414 and 2428 must be oriented as
shown.

Tighten retaining nut until alignment rod
(2419) cannot be moved. Then loosen
retaining nut until alignment rod can
move side to side with no in-and-out
movement.

9

Torque to 19 in-lb (2.1 N•m).

5

Lubricate bearing and threaded
surfaces with 115982.

10

Bond 2418 into 2427 using adhesive,
part 071023.

11

Press fit 2403 into 2424.

6

Torque to 35 in-lb (3.9 N•m).

3

FIG. 22

50

312760S

Parts

Ref
2401

Part
119912

2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413

107596
116193
120599
120885
120886
120913
120918
121167
121518
121524
121529
121530

2414

256264

2415

256268

2416
2417
2418
2419
2420

256280
256288
15G747
15K801
15K802

312760S

Description
Qty
SCREW, machined, phillips
2
pan head
SCREW, cap, hex head
1
PIN, dowel, 1/4 x 3/4
4
PIN, dowel
4
SCREW
2
SCREW
6
SCREW
6
BEARING, linear, slide
1
SCREW
6
SCREW, socket head cap
4
RING, retaining
2
RING, retaining,1-1/8 in., snap 2
SCREW, set, socket head cap,
2
M4 x 5, cone point
BLOCK, assembly, slide,
2
beam, ratio
CARRIAGE, assembly, slide,
1
beam, ratio
ARM, assembly, adjustment
1
KNOB, ratio adjustment
1
MAGNET, linear sensor
1
ROD, alignment
2
RETAINER, nut
2

Ref
2421

Description
Qty
WASHER, female, male modi- 2
fied, assembly
2422 15T377
BAR, ratio, beam
1
2423 15T383
PIN, pivot, beam, ratio
1
2424 15T384
PLATE, guide, ratio
2
2425 15T385
STUD, clevis, beam
4
2426 15T388
RETAINER, knob, adjust
1
2427 15T389
BRACKET, mounting, magnet
1
2428 15T448
CLEVIS, moving, machined
1
2429 15T449
CLEVIS, fixed, machined
1
2430 15T463
BRACKET, bar, pivot
1
2431 15T626
FRAME, base, machined
1
2432 15T715
NUT, locking, ratio adjustment
1
2433 LC0234
SENSOR, assembly
1
2434 119438
WASHER, flat
1
2435 15U196
BEARING, strip
4
2436 121573
BUMPER, urethane, 3/8-16
4
2499 ▲ * 84/0130- LABEL, warning, pinch point
1
27/11
*

Part
15K868

Not shown.

▲ Replacement Danger and Warning labels, tags, and
cards are available at no cost.

51

Parts

Air Cylinder, LC0110, LC0111, LC0230, LC0231
NOTICE
The four long screws (404) that attach the two drive
blocks (417, 418) must be tightened in a crisscross
pattern. Failure to do so may result in air cylinder
damage.
420

4
4

411

412

405

417

401

403

419

3

406
412

413
416

415
422

411 4

412
418

407
1

408

402
414

409†

412

52

404

ti12490a

2

414
415

410

1

Torque to 41 in-lb (4.6 N•m).

2

Torque to 350 in-lb (39.5 N•m).

3

Torque to 100 ft-lb (135 N•m).

4

Coat all sliding surfaces with lubricant, part 115982.

5

Apply sealant tape to npt fittings.

312760S

Parts

Ref
401
402
403

Part
107571
114100
120875
104131

404
405
406
407
408
409 †
410
411

120880
120881
120884
120899
120900
120922
120923
120932
104271

412

121018

413

121020

414
415
416

121021
121022
15K790
15K789

417
418
419

15K791
15K792
15K793
15K794

420

15K795
15T714

422

121643

Description
Qty
PACKING, o-ring
1
SCREW, cap, socket hd
3
O-RING, 3 in. (assemblies LC0110
1
and LC0230)
O-RING, 4.5 in. (assemblies
1
LC0111 and LC0231)
SCREW
4
BEARING
1
SCREW
1
VALVE, solenoid, 3 way
1
VALVE, solenoid, 3 way
1
MUFFLER, w/ integral flow control
1
FITTING, elbow, male, swivel
1
O-RING (assemblies LC0110 and
2
LC0230 only)
PACKING, o-ring (assemblies
2
LC0111 and LC0231 only)
FITTING, elbow, male, swivel,
5
1/4 npt
FITTING, elbow, male, swivel,
1
1/4 npt
MUFFLER, 1/4 npt
3
FITTING, elbow, male, 1/4 npt
2
TUBE, air, cylinder, 3.0 (assem1
blies LC0110 and LC0230 only)
TUBE, air, cylinder, 4.5 (assem1
blies LC0111 and LC0231 only)
BLOCK, air cylinder, rod end
1
BLOCK, air cylinder, blind end
1
PISTON (assemblies LC0110 and
1
LC0230 only)
PISTON (assemblies LC0111 and
1
LC0231 only)
ROD, piston, air cylinder (assem1
blies LC0110 and LC0111 only)
ROD, piston, air cylinder (assem1
blies LC0230 and LC0231 only)
FITTING, elbow, 1/4 x 1/4 npt,
1
swivel, ext (assemblies LC0230
and LC0231 only)

† When replacing the muffler, adjust the muffler setting
so that the pistons take approximately 1/2 to 1 second to retract.

312760S

53

Parts

Pump Sub-Assembly, LC0112

The pump shaft is installed with Krytox. Contact with
Krytox can lead to flu-like symptoms. The MSDS for this
material is available upon request.
513

506

514
508

507

2

511

501
504
512
503
502

3

510

ti12491a

509
505

Ref
501
502
503
504
505
506
507

54

Part
106258
108712
120887
120890
120913
120982
15K786

1

1

Torque to 350 in-lb (39.5 N•m).

2

Lube shaft with krytox grease prior to insertion into bearing.

3

Shaft seal (503) must be installed with open side facing the washer (512).

Description
Qty
PACKING, o-ring
2
NUT, hex
2
SEAL, posipak, 3/8 x 5/8, uhmwpe 2
RING, retaining
2
SCREW
4
SCREW
8
HOUSING, pump
1

Ref
508
509
510
511
512
513
514

Part
15K787
15K803
15K804
15K824
15K828
15K895
LC0093

Description
CAP, end, pump, machined
COLLAR
HOUSING, bearing, seal
ROD, piston
WASHER, housing, seal
HOUSING, check valve
KIT, rebuild, valve, check

Qty
2
2
2
2
2
2
2

312760S

Parts

Check Valve, Assembly LC0093

2104

1

2101
2102
2103

ti12565a

Chamfer

1

Ref
2101
2102
2103
2104

The side of the seat with an outside diameter chamfer
must point away from the ball.

Part
105445
121084
15D312
196832

312760S

Description
BALL, 0.5000
SPRING
BUSHING, ball guide
SEAT, lapped

Qty
1
1
1
1

55

Parts

Control Bracket, LC0240, LC0261
2513b
2513a
2510

2508

2507
2506
2512

2511

2509
2505
2502
2501
1

2503
2504

1

ti12568a

Assembly LC0240 Shown
1

Ref
2501

2502
2503
2504
2505
2506

*

Apply thread sealant tape to male npt threads.

Part
Description
Qty
15T735 BRACKET, control mounting
1
(assembly LC0240 only)
15U737 BRACKET, control mounting
1
(assembly LC0261 only)
120897 REGULATOR, air, with integral
1
gage
120954 MANIFOLD, inlet, banjo
1
121018 FITTING, elbow, male, swivel,1/4
1
NPT
LC0291 CABLE, power
1
(assembly LC0240 only)
113003 SCREW, socket head cap,10-32 x
4
0.62, stainless steel

Ref
2507
2508

Part
289697
121583

Description
Qty
BASE, Fluid Control Module
1
HARNESS, I/O, M12 x M8 x sub1
micro x mini
2509 277674 ENCLOSURE, cube door
1
2510 121685 CABLE, CAN, M12 x M12, 5P,
1
female-female, straight x right
2511 121860 SCREW, M4 x 0.7, 30 mm long,
2
stainless steel
2512 84/0153- CLAMP, harness, nylon
1
1/89
2513‹ 289696 MODULE, Fluid Control, assembly 1

Not shown.

▲ Replacement Danger and Warning labels, tags, and cards are available at no cost.
‹ When purchasing a replacement fluid control module, software token 15W046 is required to install software
before first use.

56

312760S

Parts

312760S

57

Parts

Incoming Power Bracket, LC0239
336
334

338

333
303
Part of
331

302

1

309

305

333
335

330
312

337
325
301

326

308
Ground
from
319

308

311

307

Ground
from
306

Ground
from
303

326

308

307

310

306, 318
304

329

301

314
313

2

ti17531b

317 1

314
316

58

1

1

1

Apply thread sealant tape if applicable.

2

Vent direction must point toward machine.

312760S

Parts

Ref Part
301 119912

Description
Qty
SCREW, mach. phillips pan
3
hd.
302 121018
FITTING, elbow, male,
1
swivel, 1/4 npt
303 120876
POWER SUPPLY
1
304 120882
FILTER
1
305 120883
NUT
1
306 120910
SOCKET, electrical, with EMI
1
filter
307 120916
SCREW
6
308 120993
NUT, hex, M5, with tooth
2
washer
309 15U738
BRACKET, incoming power
1
310 15K800
FITTING, bulkhead
1
311 * 84/0130-26/11 LABEL, symbol, pe
1
312 121581
HARNESS, I/O, M12 x M12
2
313 121178
VALVE, 1/4 in. OSHA lockout 1
314 121179
CLAMP
2
315 * 121180
MANIFOLD
1
316 94/0762/99
VALVE, safety, blow-off,
1
100 psi
317 94/0430/99
PLUG, pipe, 1/4 npt
2

312760S

Ref Part
318 81/1054-4/11
319
325
326
329
330
331
332
333
334
335
336
337
338
*

Description
Qty
FUSE, type f, 4 amp, 250v,
2
fast
LC0291
CABLE, power, assembly
1
* 84/2725-1/11 LABEL, symbol, CE
1
121558
CONNECTOR, power, panel
2
mount
15V092
LABEL, bracket, incoming,
1
power
104395
WASHER, lock, tooth, exter1
nal
24F228
HARNESS, wire
1
--SEALANT, pipe
1
122664
WASHER, back-up
8
100068
WASHER, lock, spring
4
125609
FASTENER, screw, shcs, M3
4
x 0.5 x 10, stainless steel
125104
NUT, hex, M3
4
114225
TRIM, edge protection
0.5
24J864
PARTITION, power
1

Not shown.

--- Not for sale.

59

Parts

Piston Package
606
1

601

606

605
603

ti12438a

602
604

1

Arrow on cylinder must point to the o-ring (606) on the right.

Nylon Piston, Stainless Steel Metering Tube
Assemblies
Reference Number and Description
Piston
Package
LC1080
LC1100
LC1120
LC1140
LC1160
LC1180
LC1200
LC1220
LC1240
LC1260
LC1280
LC1300
LC1320
LC1340
LC1360
LC1400
LC1440
LC1480
LC1520
LC1560
LC1600
LC1640
LC1720
LC1800
LC1880
LC1960
Quantity

60

601

602

Tube,
pump
LCC080
LCC100
LCC120
LCC140
LCC160
LCC180
LCC200
LCC220
LCC240
LCC260
LCC280
LCC300
LCC320
LCC340
LCC360
LCC400
LCC440
LCC480
LCC520
LCC560
LCC600
LCC640
LCC720
LCC800
LCC880
LCC960
1

Nylon
Piston
LCB080
LCB100
LCB120
LCB140
LCB160
LCB180
LCB200
LCB220
LCB240
LCB260
LCB280
LCB300
LCB320
LCB340
LCB360
LCB400
LCB440
LCB480
LCB520
LCB560
LCB600
LCB640
LCB720
LCB800
LCB880
LCB960
1

603†

604

605

606

Washer

Ring, support,
piston

Screw

O-ring

120933

120874

1

2

15M089

15M099

15M100

15M101
1

15K887

15K888

15K890

1

312760S

Parts

UHMW Piston, Stainless Steel Metering
Tube Assemblies
Reference Number and Description
Piston
Package
LC2160
LC2180
LC2200
LC2220
LC2240
LC2260
LC2280
LC2300
LC2320
LC2340
LC2360
LC2400
LC2440
LC2480
LC2520
LC2560
LC2600
LC2640
LC2720
LC2800
LC2880
LC2960
Quantity

312760S

601

602

Tube,
pump
LCC160
LCC180
LCC200
LCC220
LCC240
LCC260
LCC280
LCC300
LCC320
LCC340
LCC360
LCC400
LCC440
LCC480
LCC520
LCC560
LCC600
LCC640
LCC720
LCC800
LCC880
LCC960
1

UHMW
Piston
LCA160
LCA180
LCA200
LCA220
LCA240
LCA260
LCA280
LCA300
LCA320
LCA340
LCA360
LCA400
LCA440
LCA480
LCA520
LCA560
LCA600
LCA640
LCA720
LCA800
LCA880
LCA960
1

603†

604

605

606

Washer

Ring, support,
piston

Screw

O-ring

120933

120874

1

2

15M099

15M100

15M101
1

15K887

15K888

15K890

1

61

Parts

UHMW Piston, Ceramic Metering Tube
Assemblies
NOTE: The UHMW piston, ceramic metering tube
assemblies contain a carbide ball. This ball replaces the
standard check valve ball in pump assembly LC0112. If
a UHMW piston, ceramic metering tube assembly needs
to be installed, replace the original ball in pump assembly LC0112 with the ball included with the pump package. See Check Valve Rebuild Kit Installation on
page 36 for installation instructions.
Reference Number and Description
Piston
Package
LC3160
LC3180
LC3200
LC3220
LC3240
LC3260
LC3280
LC3300
LC3320
LC3340
LC3360
LC3400
LC3440
LC3480
LC3520
LC3560
LC3600
LC3640
LC3720
LC3800
LC3880
LC3960
Quantity

601

602

Tube,
pump
LCG160
LCG180
LCG200
LCG220
LCG240
LCG260
LCG280
LCG300
LCG320
LCG340
LCG360
LCG400
LCG440
LCG480
LCG520
LCG560
LCG600
LCG640
LCG720
LCG800
LCG880
LCG960
1

UHMW
Piston
LCA160
LCA180
LCA200
LCA220
LCA240
LCA260
LCA280
LCA300
LCA320
LCA340
LCA360
LCA400
LCA440
LCA480
LCA520
LCA560
LCA600
LCA640
LCA720
LCA800
LCA880
LCA960
1

603†

604

605

606

607

Washer

Ring, support,
piston

Screw

O-ring

Carbide
Ball

120933

120874

116166

1

2

1

15M099

15M100

15M101
1

15K887

15K888

15K890

1

† For custom piston packages, washer (603) part number will change by piston size as follows:
For piston sizes 80-100cc: 15M089
For piston sizes 101-159cc: Washer not used.
For piston sizes 160-285cc: 15M099
For piston sizes 286-646cc: 15M100
For piston sizes 647-960cc: 15M101

62

312760S

Parts

Nylon and UHMW Piston Replacement Kits
653

653

653

652

653

651
652
651
Piston Sizes 080-119
653
Piston Sizes 160-960
653

652
651

Piston Sizes 120-159
Ref
651
652
653

Part

Description
PISTON
SCREW
O-RING

Qty
1
1
2

LCF - 160
Code: A
Piston Size (mm2)

312760S

LCE - 160
Code: A
Piston Size (mm2)

When ordering a piston replacement kit, the following
intelligent part numbering system applies for Nylon
based pistons.

When ordering a UHMW replacement kit, the following
numbering applies:

The items indicated above will be supplied with the kit.
See the Product Configurator section beginning on
page 4 for available standard piston sizes.

63

Parts

Controls

Fluid Control Module

There are three options for controls.
705b
•

Advanced Display Module with one Fluid Control
Module, LC0274★

•

Advanced Display Module with two Fluid Control
Modules, LC0275★

•

Standard Display Module with one Fluid Control
Module, LC0272

705a

704
702

703

ti12711a

ti12362a

Ref
701
702
703

Part
289697
277674
121597

704

113003

Description
MODULE, base
ENCLOSURE, door
CABLE, CAN, 90 female / 90
female
SCREW, socket head cap,
10-32 x 0.62, stainless steel
MODULE, assembly,
Fluid Control Module

Qty
1
1
1
4

FIG. 23: Advanced Display Module, 24E451

705‹ 289696

★ A protective, membrane shield 15V551 is available
for the screen and softkeys of the Advanced Display
Module.

‹ When purchasing a replacement fluid control module, software token 15W046 is required to install software before first use.

64

1

312760S

Parts

Applicator Mounting
Assemblies with Upper Clamp

Assemblies with Base Clamp

803

801

816



816
802
817
808

802

802
804

805

804

805

810

810

803

809

803

809
806
808

806

808

813

807

807

816

816
ti21830a

811

/&

812
814
Ref
801
802
803
804
805
806
807
808

Part
16P082
16P409
16P550
121194
15K832
120913
15M658
121013

809

121046

810

94/0705-1/96

811

15U176

812

120908

312760S

Description
Qty
BASE, arm, mounting
1
BLOCK, mounting, front
2
BLOCK, mounting, rear
2
SCREW
1
ARM, mounting, display
1
SCREW
2
CLAMP
1
SCREW, socket head cap,
4
M5-0.8 x 25, mild steel
TUBE, 1/4 x 1/4 twin, polyure6
thane
FITTING, elbow, swivel, 1/4
2
tube x 1/8 npt
CLAMP, base (assemblies
1
256438 and LC0293 only)
WASHER, plain M8 (assem2
blies 256438 and LC0293
only)

Ref
813

Part
96/0045/98

814

120913

815

* 121003

816
817

126510
121273

*

Description
Qty
WASHER, lock, split, 5/16 in.,
2
stainless steel (assemblies
256438 and LC0293 only)
SCREW (assemblies 256438
2
and LC0293 only)
CABLE, CAN, female / female
1
3.0 m (assemblies 256438
and LC0293 only)
PLUG, round, finishing, 7/8 in. 2
SCREW, socket head cap, 0.8
2
x 35, mild steel

Not shown.

65

Parts

Dispense Valve
Standard Dispense Valves, 255179 and
255181
See MD2 manual for parts information. See Related
Manuals on page 3.

Gun Mounted MD2 Valves, LC0120 and LC0122

901a

902
903

901b

Assembly LC0120 Shown

Ref
901

Part
LC0006
LC0004

901a † 255181
† 255179
901b 255208
902 121198
123660
903

120953

ti12440a

Description
VALVE, assembly, 10:1, gun, electric
(assembly LC0122 only)
VALVE, assembly, 1:1, gun, electric
(assembly LC0120 only)
VALVE, dispense, 10:1, soft seats
(assembly LC0122 only)
VALVE, dispense, 1:1, soft seats
(assembly LC0120 only)
HANDLE, 2K dispense valve, electric
CORD, euro, male, 4 pin, 3 wire, 6 m
(Series A Handles only)
CORD, euro, male/female, 6 m
(Series B Handles only)
CONNECTOR, splitter

Qty
1
1
1
1
1
1
1
1

† See MD2 manual for dispense valve and dispense valve handle parts information. See Related Manuals on
page 3.

66

312760S

Parts

Lever Actuated MD2 Valves, LC0121 and LC0123

1101a

1101b
1103

1102

Assembly LC0121 Shown
ti12441a

Ref Part
1101 LC0005
LC0007
1101a 255249
1101b † 255181
† 255179
1102 121198
123660
1103 120953

Description
VALVE, assembly, 1:1, lever, electric
(assembly LC0121 only)
VALVE, assembly, 10:1, lever, electric
(assembly LC0123 only)
LEVER, 2K dispense valve
VALVE, dispense, 10:1, soft seats
(assembly LC0123 only)
VALVE, dispense, 1:1, soft seats
(assembly LC0121 only)
CORD, euro, male, 4 pin, 3 wire, 6 m
(Series A Handles only)
CORD, euro, male/female, 6 m
(Series B Handles only)
CONNECTOR, splitter

Qty
1
1
1
1
1
1
1
1

† See MD2 manual for dispense valve and dispense valve lever parts information. See Related Manuals on
page 3.

312760S

67

Parts

Mixers

1301
1303

1302

Assembly LC0061 Shown

ti12442a

Reference Number and Description
Mixer
Package
LC0057

1301

1302

1303

Description

Mixer

Shroud

Sleeve

1/4 in. X 24

60/0204/50

94/0883-C/98

LC0058

3/8 in. x 24

60/0200/50

94/0883-D/98

LC0059

3/8 in. x 36

60/0201/50

94/0883-E/98

LC0060

3/8 in. combo

60/0202/50

94/0883-E/98

LC0061

3/16 in. x 32 Luer Lock

60/0212/50

94/0883-L/98

60/0313/97
60/0305/97

LC0062

1/4 in. x 24 Luer Lock

60/0209/50

94/0883-M/98

LC0063

3/16 in. x 32

60/0206/50

94/0884-1/98

LC0295

1/2 in. x 24

60/0111-1/50

94/0885-36/98

LC0296

12 in. x 36

60/0117-1/50

94/0885-24/98

Quantity

10

1

68

1

312760S

Parts

Hose Packages
Unheated, Non-Recirculating Hoses

1404
1403

1401

1402

Assembly LC0801 Shown

ti12446a
1

Apply thread sealant tape to male npt threads before assembly.

Reference Number and Description
Hose Package Description
LC0801
3/16 in. x 30 in.
LC0802
3/16 in. x 120 in.
LC0803
3/16 in. x 180 in.
LC0804
1/4 in. x 30 in.
LC0805
1/4 in. x 120 in.
LC0806
1/4 in. x 180 in.
LC0807
3/8 in. x 30 in.
LC0808
3/8 in. x 120 in.
LC0809
3/8 in. x 180 in.
LC0400
3/8 in. x 30 in.
LC401
3/8 in. x 120 in.
LC402
3/8 in. x 180 in.
LC0810
1/2 in. x 30 in.
LC0811
1/2 in. x 120 in.
LC0812
1/2 in. x 180 in.
LC0403
1/2 in. x 30 in.
LC0404
1/2 in. x 120 in.
LC0405
1/2 in. x 180 in.
LC0813
3/4 in. x 120 in.
LC0814
3/4 in. x 180 in.
LC0406
3/4 in. x 120 in.
LC0407
3/4 in. x 180 in.
Quantity

312760S

1401

1402

1403

1404

Hose Assembly
16C501
16C506
16C507
16C510
16C515
16C516
16C519
16C524
16C525
16D261
16D266
16D267
16C529
16C534
16C535
16D271
16D276
16D277
16C544
16C545
16D286
16D287
1

90 Deg Elbow
94/0144-S/25
94/0144-S/25
94/0144-S/25
94/0148-S/25
94/0148-S/25
94/0148-S/25
94/0149-S/25
94/0149-S/25
94/0149-S/25
94/0149-S/25
94/0149-S/25
94/0149-S/25
94/0150-S/25
94/0150-S/25
94/0150-S/25
94/0150-S/25
94/0150-S/25
94/0150-S/25
94/0153-S/25
94/0153-S/25
94/0153-S/25
94/0153-S/25
1

Adapter
94/1000/98
94/1000/98
94/1000/98
J6900040
J6900040
J6900040
94/1007/98
94/1007/98
94/1007/98
94/1007/98
94/1007/98
94/1007/98
94/1009/98
94/1009/98
94/1009/98
16C399
16C399
16C399
94/1083/98
94/1083/98
94/1083/98
94/1083/98
1

Bushing
94/0488/98
94/0488/98
94/0488/98

1

69

Parts

Unheated, Recirculating Hose Packages

1603

1602

1603
1602

1601

Assembly LC0161 shown installed as the
Low Volume and High Volume Side Hose
Package
1601

2

ti12444a
1

Apply thread sealant tape to male npt threads before assembly.

2

Dispense valve shown for reference only.

Reference Number and Description
Hose
Package Description
LC0161 3/16 in. x 30 in., on-board
LC0162 3/16 in. x 120 in.,
on-board
LC0163 3/16 in. x 180 in.,
on-board
LC0164 1/4 in. x 30 in., on-board
LC0165 1/4 in. x 120 in., on-board
LC0166 1/4 in. x 180 in., on-board
LC0167 3/8 in. x 30 in., on-board
LC0168 3/8 in. x 120 in., on-board
LC0169 3/8 in. x 180 in., on-board
LC0432 3/8 in. x 30 in., on-board,
high pressure
Quantity

70

1601

1602

1603

1604

1605

Valve
Assembly
255977
255977

Supply Hose
Assembly
255983
255984

Return Hose
Assembly
255997
255998

Pressure
Sensor
16A093
16A093

O-Ring
111457
111457

255977

255985

255999

16A093

111457

255976
255976
255976
255975
255975
255975
255975

255986
255987
255988
255989
255990
255991
LC0408

258058
258059
258060
258061
258062
258063
LC0416

16A093
16A093
16A093
16A093
16A093
16A093
16A093

111457
111457
111457
111457
111457
111457
111457

1

1

1

1

1

312760S

Parts

Reference Number and Description
Hose
Package Description
LC0433 3/8 in. x 120 in., on-board,
high pressure
LC0434 3/8 in. x 180 in., on-board,
high pressure
LC0170 1/2 in. x 30 in., on-board
LC0171 1/2 in. x 120 in., on-board
LC0172 1/2 in. x 180 in., on-board
LC0435 1/2 in. x 30 in., on-board,
high pressure
LC0436 1/2 in. x 120 in., on-board,
high pressure
LC0437 1/2 in. x 180 in., on-board,
high pressure
LC0173 3/4 in. x 120 in., on-board
LC0174 3/4 in. x 180 in., on-board
LC0438 3/4 in. x 120 in., on-board,
high pressure
LC0439 3/4 in. x 180 in., on-board,
high pressure
LC0175 3/16 in. x 30 in., off-board
LC0176 3/16 in. x 120 in.,
off-board
LC0177 3/16 in. x 180 in.,
off-board
LC0178 1/4 in. x 30 in., off-board
LC0179 1/4 in. x 120 in., off-board
LC0180 1/4 in. x 180 in., off-board
LC0181 3/8 in. x 30 in., off-board
LC0182 3/8 in. x 120 in., off-board
LC0183 3/8 in. x 180 in., off-board
LC0440 3/8 in. x 30 in., off-board,
high pressure
LC0441 3/8 in. x 120 in., off-board,
high pressure
LC0442 3/8 in. x 180 in., off-board,
high pressure
LC0184 1/2 in. x 30 in., off-board
LC0185 1/2 in. x 120 in., off-board
LC0186 1/2 in. x 180 in., off-board
LC0443 1/2 in. x 30 in., off-board,
high pressure
LC0444 1/2 in. x 120 in., off-board,
high pressure
Quantity

312760S

1601

1602

1603

1604

1605

Valve
Assembly
255975

Supply Hose
Assembly
LC0409

Return Hose
Assembly
LC0417

Pressure
Sensor
16A093

O-Ring
111457

255975

LC0410

LC0418

16A093

111457

255974
255974
255974
255974

255992
255993
255994
LC0411

258064
258065
258066
LC0419

16A093
16A093
16A093
16A093

111457
111457
111457
111457

255974

LC0412

LC0420

16A093

111457

255974

LC0413

LC0421

16A093

111457

255974
255974
255974

255995
255996
LC0414

258067
258068
LC0422

16A093
16A093
16A093

111457
111457
111457

255974

LC0415

LC0423

16A093

111457

255977
255977

255983
255984

258069
258070

16A093
16A093

111457
111457

255977

255985

258071

16A093

111457

255976
255976
255976
255975
255975
255975
255975

255986
255987
255988
255989
255990
255991
LC0408

258072
258073
258074
258075
258076
258077
LC0424

16A093
16A093
16A093
16A093
16A093
16A093
16A093

111457
111457
111457
111457
111457
111457
111457

255975

LC0409

LC0425

16A093

111457

255975

LC0410

LC0426

16A093

111457

255974
255974
255974
255974

255992
255993
255994
LC0411

258078
258079
258080
LC0427

16A093
16A093
16A093
16A093

111457
111457
111457
111457

255974

LC0412

LC0428

16A093

111457

1

1

1

1

1

71

Parts

Reference Number and Description
Hose
Package Description
LC0445 1/2 in. x 180 in., off-board,
high pressure
LC0187 3/4 in. x 120 in., off-board
LC0188 3/4 in. x 180 in., off-board
LC0446 3/4 in. x 120 in., off-board,
high pressure
LC0447 3/4 in. x 180 in., off-board,
high pressure
Quantity

72

1601

1602

1603

1604

1605

Valve
Assembly
255974

Supply Hose
Assembly
LC0413

Return Hose
Assembly
LC0429

Pressure
Sensor
16A093

O-Ring
111457

255974
255974
255974

255995
255996
LC0414

258081
258082
LC0430

16A093
16A093
16A093

111457
111457
111457

255974

LC4015

LC0431

16A093

111457

1

1

1

1

1

312760S

Parts

Heated, Recirculating Hose Packages
1702

1703

1704

1702
1703

1701

1705

2

1701

Assembly LC0190 shown installed as
the Low Volume and High Volume
Side Hose Package

ti12443b

1

Apply thread sealant tape to male npt threads before assembly.

2

Dispense valve shown for reference only.

Reference Number and Description

Hose
Package
LC0190
LC0191
LC0192
LC0193
LC0194
LC0195
LC0472
LC0473

312760S

Description
1/4 in. x 30 in., on-board
1/4 in. x 120 in., on-board
1/4 in. x 180 in., on-board
3/8 in. x 30 in., on-board
3/8 in. x 120 in., on-board
3/8 in. x 180 in., on-board
3/8 in. x 30 in., on-board,
high pressure
3/8 in. x 120 in., on-board,
high pressure
Quantity

1701

1702

1703

1704

1705

Valve
Assembly
255976
255976
255976
255975
255975
255975
255975

Heated
Supply Hose
Assembly
258084
258085
258086
258087
258088
258089
258087

Insulated
Return Hose
Assembly
258095
258096
258097
258098
258099
258121
LC0456

Pressure
Sensor
16A093
16A093
16A093
16A093
16A093
16A093
16A093

O-Ring
111457
111457
111457
111457
111457
111457
111457

255975

258088

LC0457

16A093

111457

1

1

1

1

1

73

Parts

Reference Number and Description

Hose
Package
LC0474
LC0196
LC0197
LC0198
LC0475
LC0476
LC0477
LC0199
LC0200
LC0478
LC0479
LC0201
LC0202
LC0203
LC0204
LC0205
LC0206
LC0480
LC0481
LC0482
LC0207
LC0208
LC0209
LC0483
LC0484
LC0485
LC0210
LC0211
LC0486
LC0487

74

Description
3/8 in. x 180 in., on-board,
high pressure
1/2 in. x 30 in., on-board
1/2 in. x 120 in., on-board
1/2 in. x 180 in., on-board
1/2 in. x 30 in., on-board,
high pressure
1/2 in. x 120 in., on-board,
high pressure
1/2 in. x 180 in., on-board,
high pressure
3/4 in. x 120 in., on-board
3/4 in. x 180 in., on-board
3/4 in. x 120 in., on-board,
high pressure
3/4 in. x 180 in., on-board,
high pressure
1/4 in. x 30 in., off-board
1/4 in. x 120 in., off-board
1/4 in. x 180 in., off-board
3/8 in. x 30 in., off-board
3/8 in. x 120 in., off-board
3/8 in. x 180 in., off-board
3/8 in. x 30 in., off-board,
high pressure
3/8 in. x 120 in., off-board,
high pressure
3/8 in. x 180 in., off-board,
high pressure
1/2 in. x 30 in., off-board
1/2 in. x 120 in., off-board
1/2 in. x 180 in., off-board
1/2 in. x 30 in., off-board,
high pressure
1/2 in. x 120 in., off-board,
high pressure
1/2 in. x 180 in., off-board,
high pressure
3/4 in. x 120 in., off-board
3/4 in. x 180 in., off-board
3/4 in. x 120 in., off-board,
high pressure
3/4 in. x 180 in., off-board,
high pressure
Quantity

1701

1702

1703

1704

1705

Valve
Assembly
255975

Heated
Supply Hose
Assembly
258089

Insulated
Return Hose
Assembly
LC0458

Pressure
Sensor
16A093

O-Ring
111457

255974
255974
255974
255974

258090
258091
258092
258090

258122
258123
258124
LC0459

16A093
16A093
16A093
16A093

111457
111457
111457
111457

255974

258091

LC0460

16A093

111457

255974

258092

LC0461

16A093

111457

255974
255974
255974

258093
258094
258093

258125
258126
LC0462

16A093
16A093
16A093

111457
111457
111457

255974

258094

LC0463

16A093

111457

255976
255976
255976
255975
255975
255975
255975

258084
258085
258086
258087
258088
258089
258087

258127
258128
258129
258130
258131
258132
LC0464

16A093
16A093
16A093
16A093
16A093
16A093
16A093

111457
111457
111457
111457
111457
111457
111457

255975

258088

LC0465

16A093

111457

255975

258089

LC0466

16A093

111457

255974
255974
255974
255974

258090
258091
258092
258090

258133
258134
258135
LC0467

16A093
16A093
16A093
16A093

111457
111457
111457
111457

255974

258091

LC0468

16A093

111457

255974

258092

LC0469

16A093

111457

255974
255974
255974

258093
258094
258093

258136
258137
LC0470

16A093
16A093
16A093

111457
111457
111457

255974

258094

LC0471

16A093

111457

1

1

1

1

1

312760S

Parts

Heated, Non-Recirculating Hoses
1503

1504

1501

1502

Part LC0881 Shown
ti12445a

1

Apply thread sealant tape to male npt threads before assembly.

Reference Number and Description

Hose Package Description
LC0881
1/4 in. x 30 in.
LC0882
1/4 in. x 120 in.
LC0883
1/4 in. x 180 in.
LC0884
3/8 in. x 30 in.
LC0885
3/8 in. x 120 in.
LC0886
3/8 in. x 180 in.
LC0887
1/2 in. x 30 in.
LC0888
1/2 in. x 120 in.
LC0889
1/2 in. x 180 in.
LC0890
3/4 in. x 120 in.
LC0891
3/4 in. x 180 in.
Quantity
*

1501

1502

1503

1504

* 1505

* 1506

Heated
Hose
Assembly
16C554
16C558
16C559
16C562
16C566
16C567
16C570
16C574
16C575
16C582
16C583
1

90 Degree
Elbow
94/0148-S/25
94/0148-S/25
94/0148-S/25
94/0149-S/25
94/0149-S/25
94/0149-S/25
94/0150-S/25
94/0150-S/25
94/0150-S/25
94/0153-S/25
94/0153-S/25
1

Adapter
J6900040
J6900040
J6900040
94/1007/98
94/1007/98
94/1007/98
16C399
16C399
16C399
94/0103/98
94/0103/98
1

45 Degree
Elbow
121041
121041
121041
121042
121042
121042
121043
121043
121043
121044
121044
1

Circuit
Breaker
121630
121632
121633
121630
121632
16E546
121630
121632
16E546
121632
16E546
1

Extension
Cord
121683
121683
121683
121683
121683
121683
121683
121683
121683
121683
121683
1

Not shown.

312760S

75

Parts

Power Cords

ti12447a

Part 121054 Shown

Power
Cord
Package
121054
121055
121056
121057
121058
121060
124861
124862
124863
124864

76

Description
CORD SET, 250V, 10A, United States
CORD SET, 250V, 10A, North America
CORD SET, 250V, 10A, Continental Europe
CORD SET, 250V, 10A, United Kingdom/Ireland
CORD SET, 250V, 10A, Israel
CORD SET, 250V, 10A, India
CORD SET, 250V, 10A, Italy
CORD SET, 250V, 10A, Denmark
CORD SET, 250V, 10A, Switzerland
CORD SET, 250V, 10A, Australia

312760S

Parts

Flow Monitoring
Part Number and Quantity
Flow
Monitoring
Package
LC0302
LC0303
LC0304
LC0305
LC0306
LC0307
LC0312
LC0313
LC0314
LC0315
LC0316
LC0317

Flow Meters
0.5 gpm,
LC0299
2
1
1

Pressure
2.0 gpm, Transducer, Pump Plug,
LC0301
257433
LC0041

1.0 gpm,
LC0300
1

1
2
1

2
1
1

1

1
2

1
1
2
1

1

1
2

Pump Plug, Assembly LC0041

Pressure Transducer, Assembly 257433
1902

1802
1901

1801

ti13391b

ti12448a

Ref Part
1801 15K815
1802 111457

312760S

Description
PLUG, dummy, transducer
PACKING, o-ring

Qty
2
2

Ref Part
1901 16A093
1902 111457

Description
SENSOR, pressure
O-RING

Qty
2
2

77

Parts

Flow Meters
2005
2004
2001

2003

ti13390a

2002

Ref
2001
2002
2003
2004
2005

78

Description
METER, flow
SENSOR, meter, flow
ADAPTER, reducer
FITTING, nipple, hex
FITTING, adapter

0.5 gpm Flow 1.0 gpm Flow 2.0 gpm Flow
Meter Assy,
Meter Assy,
Meter Assy,
LC0299
LC0300
LC0301
121932
121933
121934
121909
94/0745/98
121907
121908

Qty
1
1
1
1
1

312760S

Parts

Tank Stands, Assemblies
LC0247 and LC0103

Heat Zone Assemblies
See Integrated Heat manual referenced at the beginning
of this manual for Heat Zone Assemblies parts information.

2001

2002

ti12473a

Assembly LC0247 Shown
Ref Part
2001 121097

Description
Qty
FASTENER, u-bolt with mounting
4
plate
2002 15U373 SUPPORT, tank stand, variable
1
ratio (assembly LC0247 only)
15M478 SUPPORT, off-board tank stand
1
(assembly LC0103 only)

312760S

79

Kits

Kits
Mixer and Shroud Options

Machine Rebuild Kits

Part
LC0063

Part
LC0091
LC0092
LC0093
LC0318
LC0094

LC0057
LC0058
LC0059
LC0060
LC0061
LC0062
LC0077
LC0078
LC0079
LC0080
LC0081
LC0083
LC0082
LC0084
LC0085
LC0086
LC0087
LC0088
LC0089
LC0090

Description
Mixer, 3/16 in. (6.5 mm) x 32, 10 Mixers
with shroud
Mixer, 1/4 in. (6.5 mm) x 24, 10 Mixers
with shroud
Mixer, 3/8 in. (9.8 mm) x 24, 10 Mixers
with shroud
Mixer, 3/8 in. (9.8 mm) x 36, 10 Mixers
with shroud
Mixer, 3/8 in. (9.8 mm) Combo, 10 Mixers
with shroud
Mixer, 3/16 in. (4.8 mm) x 32 Luer Lock, 10
Mixers with shroud
Mixer, 1/4 in. (6.5 mm) x 24 Luer Lock, 10
Mixers with shroud
Mixer, 3/16 in. (4.8 mm) x 32, 50 Mixers
Mixer, 1/4 in. (6.5 mm) x 24, 50 Mixers
Mixer, 3/8 in. (9.8 mm) x 24, 50 Mixers
Mixer, 3/8 in. (9.8 mm) x 36, 50 Mixers
Mixer, 3/8 in. (9.8 mm) combo, 50 Mixers
Mixer, 1/4 in. (6.5 mm) x 24 Luer Lock, 50
Mixers
Mixer, 3/16 in. (4.8 mm) x 32 Luer Lock, 50
Mixers
Mixer, 3/16 in. (4.8 mm) x 32, 250 Mixers
Mixer, 1/4 in. (6.5 mm) x 24, 250 Mixers
Mixer, 3/8 in. (9.8 mm) x 24, 250 Mixers
Mixer, 3/8 in. (9.8 mm) x 36, 250 Mixers
Mixer, 3/8 in. (9.8 mm) combo, 250 Mixers
Mixer, 3/16 in. (4.8 mm) x 32 Luer Lock,
250 Mixers
Mixer, 1/4 in. (6.5 mm) x 24 Luer Lock, 250
Mixers

Description
3.0 in. Air Cylinder rebuild kit
4.5 in. Air Cylinder rebuild kit
Check Valve rebuild kit, Stainless Steel Ball
Check Valve rebuild kit, Carbide Ball
Rear Pump Seal rebuild kit

Tank Accessories
Part
LC0097

Description
Desiccant Dryer, 3/8 in. NPT with adapter
and cartridge
LC0098
Desiccant Dryer refill cartridge
‹LC0095 Nitrogen Harness Kit for 30 L and 60 L
tank, 1 tank
‹LC0096 Nitrogen Harness Kit for 30 L and 60 L
tank, 2 tanks
†LC0099
Vacuum Transfer Pump, 120V, down to 25
Torr
†LC0100
Vacuum Transfer Pump, 240V, down to 25
Torr

†

‹

Item includes only the pump. A vacuum kit must be purchased to install the pump onto the tank.
Kit includes all parts needed to connect a nitrogen tank
to the material tank.

MD2 Valve Kits
See MD2 Dispense Valve instruction manual referenced at the beginning of this manual for installation instructions or for more information.

Part
255217
255218
255219
255220

80

Description
MD2, kit rebuild, air cylinder
MD2, kit rebuild, back-end of wet section
(no needle or seat)
MD2, Soft Seat rebuild, needle and nose
MD2, convert Soft Seat nose to Hard Seat
(Hard Seat rebuild), needle and nose

312760S

Kits

Vacuum Kits

Refill Kits

These vacuum kits contain the parts necessary to
attach a vacuum pump to the tanks.

Refill Kits 256659 and 256660 are designed to turn on
and off a transfer pump as needed to keep the tanks at
the proper fluid level. Tank Refill Kit 256577 is designed
to open and close a valve to allow fluid to flow into the
tank from an always-on transfer pump. Tank Refill
Kit 256577 includes the parts necessary to install on the
base or lid of a 7.5 L, 30 L, or 60 L tank.

On-Board
Vacuum Kits

ti12589a

ti12588a

ti12590a

Assembly 256206
Shown

Part
256205
256206
256207
256208

Off-Board
Vacuum Kits

Assembly 256207
Shown

Description
Vacuum Kit, Single On-Board Tank
Vacuum Kit, Two On-Board Tanks
Vacuum Kit, Single Off-Board Tank
Vacuum Kit, Two Off-Board Tanks

Assembly 256659
Shown

ti12591a

Assembly 256577 shown
installed on tank for reference

Part
256659
256660
256577

Description
Refill Kit, 1/4 npt, solenoid, 24V
Refill Kit, 1/2 npt, solenoid, 24V
Tank Refill Kit

External Control Interface Connection Kit
Part
LC0008

312760S

Description
Cord, I/O interface and splitter

81

Dimensions

Dimensions
Machine with On-Board Tanks

A
D
ti12621b

ti12622b

C

B

PR70
† Assembly Dimensions, in. (mm)
‹ Stainless Steel Tanks

Polyethylene Tanks
Ref
A
B
C
D

No Agitators

With Agitators

3L

7.5 L, No
Agitators

7.5 L, with
Agitators

26.4 (670)
18.5 (470)
30.6 (778)
13.4 (340)

38.6 (980)
18.5 (470)
30.6 (778)
13.4 (340)

28.2 (716)
15.5 (394)
30.6 (778)
13.4 (340)

38.2 (970)
15.5 (394)
30.6 (778)
13.4 (340)

39.9 (1013)
15.5 (394)
30.6 (778)
13.4 (340)

PR70v
† Assembly Dimensions, in. (mm)
Polyethylene Tanks
Ref
A
B
C
D
†

‹

82

‹ Stainless Steel Tanks

No Agitators

With Agitators

3 L, No
Agitators

30.0 (762)
20.9 (531)
38.6 (980)
14.3 (363)

39.4 (1001)
20.9 (531)
38.6 (980)
14.3 (363)

29.0 (737)
20.9 (531)
38.6 (980)
14.3 (363)

7.5 L, No
Agitators

7.5 L, with
Agitators

39.0 (991)
20.9 (531)
38.6 (980)
14.3 (363)

40.6 (1031)
20.9 (531)
38.6 (980)
14.3 (363)

Assembly dimensions listed are maximum for all assemblies under the given title.
On-board stainless steel tank dimensions include ball valves and vacuum de-gas in maximum height calculation.

312760S

Machine with Off-Board Tanks

A

D
ti12624c

ti12623c

C

B

PR70
† Assembly Dimensions, in. (mm)
30 L Tank
Ref
A
B
C
D

60 L Tank

No Agitators

With Agitators

No Agitators

With Agitators

75.7 (1923)
32.1 (815)
29.3 (236)
16.0 (406)

83.4 (2118)
32.1 (815)
29.3 (236)
16.0 (406)

64.9 (1648)
32.1 (815)
29.3 (236)
16.0 (406)

89.5 (2273)
32.1 (815)
29.3 (236)
16.0 (406)

PR70v
† Assembly Dimensions, in. (mm)
30 L Tank
Ref
A
B
C
D

60 L Tank

No Agitators

With Agitators

No Agitators

With Agitators

75.7 (1923)
32.1 (815)
40.1 (1019)
17.0 (432)

83.4 (2118)
32.1 (815)
40.1 (1019)
17.0 (432)

64.9 (1648)
32.1 (815)
40.1 (1019)
17.0 (432)

89.5 (2273)
32.1 (815)
40.1 (1019)
17.0 (432)

† Assembly dimensions listed are maximum for all assemblies under the given title.

Technical Data

Technical Data
Metering Pump Effective Area . . . . . . . . . . . . . . . . . . . . . 80 to 960 mm2 (0.124 to 1.49 in.2) per side
Small Air Cylinder Effective Area . . . . . . . . . . . . . . . . . . 4560 mm2 (7.07 in.2)
Large Air Cylinder Effective Area . . . . . . . . . . . . . . . . . . 10260 mm2 (15.9 in.2)
Maximum Stroke Length . . . . . . . . . . . . . . . . . . . . . . . . . 38.1 mm (1.50 in.)
Minimum Stroke Length . . . . . . . . . . . . . . . . . . . . . . . . . 5.8 mm (0.23 in.)
Volume per Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 to 70 cc (0.12 to 4.3 in.3)
Pump Cycles per 1 L (0.26 gal) . . . . . . . . . . . . . . . . . . . . 14.3 to 500 cycles (varies by piston size)
Ratios (fixed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1 to 12:1 (depending upon cylinders selected)
Maximum Fluid Working Pressure . . . . . . . . . . . . . . . . . 3000 psi (20.7 MPa, 207 bar)
Maximum Air Input Pressure . . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Maximum Cycle Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 cycles per minute
Maximum Operating Temperature . . . . . . . . . . . . . . . . . . 70°C (160°F), nylon pistons 50°C (120°F) UHMWPE pistons or PE Tanks
Air Inlet Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 NPT female
Pump Fluid Outlet Size . . . . . . . . . . . . . . . . . . . . . . . . . . -03, -04, -06, -08 or –12 JIC fittings for 3/16 in. (4.8 mm),
1/4 in. (6.4 mm), 3/8 in. (9.5 mm), 1/2 in. (12.7 mm),
3/4 in. (19.1 mm) hoses
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303/304, 17-4 PH, hard chrome, Chromex™, carbide,
Chemical Resistant O-rings, PTFE, nylon, UHMWPE
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 kg (120 lb) typical with two 7.5 L tanks
150 kg (330 lb) typical with two 60 L tanks
Sound Pressure Level (at typical operator station for
machine mounted Dispense Valve) . . . . . . . . . . . . . . . . . 82 dBA
Compressed Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 10 scfm typical (varies with cycle times)
Electrical Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . •
•
•
•

84

100-240V 50/60Hz, 1 phase for machine – 80 Watts
208-240V 50/60Hz, 1 phase for heat – 11 kW max
120 or 240 VAC 50/60Hz 1 phase for on-board agitators, 80 Watts
240 VAC 50/60Hz 1 phase for off-board agitators,
600 Watts

312760S

Technical Data

312760S

85

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Toll Free: 1-800-746-1334 or Fax: 330-966-3006.

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents.
Original instructions. This manual contains English. MM 312760

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revised February 2014



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.4-c002 1.000000, 0000/00/00-00:00:00
Format                          : application/pdf
Subject                         : 312760S - PR70 and PR70v, Repair - Parts, English, 312760 - PR70 and PR70v, Repair - Parts, English
Description (x-repair)          : 312760 - PR70 and PR70v, Repair - Parts, English
Modified                        : 2014:02:28 15:29:37.929-06:00
Creator                         : Heath McCartney
Title (x-repair)                : 312760S - PR70 and PR70v, Repair - Parts, English
Modify Date                     : 2014:02:27 15:03:14-06:00
Create Date                     : 2008:08:29 08:19:36-05:00
Metadata Date                   : 2014:02:27 15:03:14-06:00
Creator Tool                    : FrameMaker 9.0
Extracted                       : 2014:02:28 15:29:36.534-06:00
Sha 1                           : e4924f38824be41e21ea5eb5a72ed72ce5fe9b21
Author                          : Heath McCartney
Keywords                        : "312760 - PR70 and PR70v, Repair - Parts, English"
Job Ref                         : A107M00000, Z085654
Copyright                       : 2008, Rev S February 2014
Producer                        : Acrobat Distiller 7.0 (Windows)
Marked                          : True
Web Statement                   : 312760S - PR70 and PR70v, Repair - Parts, English
Document ID                     : uuid:100b814f-b36c-4a12-bdf2-7e4189930bd2
Instance ID                     : uuid:230a58eb-c603-4bed-9bc2-a6325b8273f3
Page Mode                       : UseOutlines
Page Count                      : 86
Title                           : 312760S - PR70 and PR70v, Repair - Parts, English
EXIF Metadata provided by EXIF.tools

Navigation menu