Graco 313516G Automatic Airpro Spray Guns Users Manual Guns, Instructions Parts, English

2015-04-02

: Graco Graco-313516G-Automatic-Airpro-Spray-Guns-Users-Manual-686463 graco-313516g-automatic-airpro-spray-guns-users-manual-686463 graco pdf

Open the PDF directly: View PDF PDF.
Page Count: 44

DownloadGraco Graco-313516G-Automatic-Airpro-Spray-Guns-Users-Manual- 313516G - Automatic AirPro Spray Guns, Instructions-Parts, English  Graco-313516g-automatic-airpro-spray-guns-users-manual
Open PDF In BrowserView PDF
Instructions-Parts

Automatic AirPro®
Spray Guns

313516G
EN

Conventional, HVLP, and Compliant guns for spraying paints and coatings.
For professional use only.
See page 2 for model information.
100 psi (0.7 MPa, 7 bar) Maximum Working Fluid Pressure
100 psi (0.7 MPa, 7 bar) Maximum Working Air Pressure

Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.

ti13585a

Part 24A749 Conventional Gun shown
mounted on Part 288217 Manifold.

ti13586a

Part 24A753 Conventional Gun with fluid control
shown mounted on Part 288223 Manifold.

II 2 G c IIB T6

Models

Contents
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Selection Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Air Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Mounting Hole Layouts . . . . . . . . . . . . . . . . . . . . . 38
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 44
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 44

Models
NOTE: A manifold is required for each gun to be installed. Refer to the Parts section for manifold
information.

Application

2

Orifice Size
in. (mm) Conventional

HVLP

Compliant

General Metal

0.020 (0.5)

24B333

24B334

24B335

General Metal

0.030 (0.8)

24A747

24A754

24A761

General Metal

0.042 (1.1)

24A748

24A755

24A762

General Metal

0.055 (1.4)

24A749

24A756

24A763

General Metal

0.070 (1.8)

24A750

24A757

24A764

General Metal with Fluid Control Knob

0.030 (0.8)

24A751

24A758

24A765

General Metal with Fluid Control Knob

0.042 (1.1)

24A752

24A759

24A766

General Metal with Fluid Control Knob

0.055 (1.4)

24A753

24A760

24A767

High Wear

0.059 (1.5)

24A774

24A776

24A778

High Wear

0.070 (1.8)

24A775

24A777

24A779

High Wear

0.086 (2.2)

24B336

High Wear

0.110 (2.8)

24C316

Wood

0.030 (0.8)

24A768

24A770

24A772

Wood

0.040 (1.0)

24A769

24A771

24A773

313516G

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers
to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings
may be found throughout the body of this manual where applicable.

WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or
explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric
lamps, and plastic drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when
flammable fumes are present.
• Ground all equipment in the work area.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail.
• If there is static sparking or you feel a shock, stop operation immediately. Do not
use equipment until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest
rated system component. See Technical Data in all equipment manuals.
• Do not leave the work area while equipment is energized or under pressure. Turn
off all equipment and follow the Pressure Relief Procedure in this manual when
equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with
genuine manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and
hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

313516G

3

Warnings

WARNING
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the
eyes or on skin and cause serious injury.
• Follow Pressure Relief Procedure in this manual, when you stop spraying and
before cleaning, checking, or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on
skin, inhaled, or swallowed.
• Read MSDS’s to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
• Always wear impervious gloves when spraying or cleaning equipment.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when
in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment
includes but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection

4

313516G

Selection Charts

Selection Charts
TERMS
Light Fluid: Up to 18 seconds with No. 2 Zahn
cup (20 centipoise)
Medium Fluid:19 to 28 seconds with No. 2
Zahn cup (20-64 centipoise)

Heavy Fluid: Greater than 28 seconds with
No. 2 Zahn cup (greater than 64 centipoise) -2.8 Volatile Organic Compounds, High-solid
Polyurethanes, Heavy Waterborne Enamels

General Metal Applications
Includes:

Gun
Assembly
Part No.
24B333
24A747
24A748
24A749
24A750
24B334
24A754
24A755
24A756
24A757
24B335
24A761
24A762
24A763
24A764
24A751★
24A752★
24A753★
24A758★
24A759★
24A760★
24A765★
24A766★
24A767★

Type
Conventional
Conventional
Conventional
Conventional
Conventional
HVLP
HVLP
HVLP
HVLP
HVLP
Compliant
Compliant
Compliant
Compliant
Compliant
Conventional
Conventional
Conventional
HVLP
HVLP
HVLP
Compliant
Compliant
Compliant

Air Cap
Needle/ Air Cap
Part No.
Nozzle Kit with Pin (without pin,
Part No. Part No. for reference)

24B332
24A687
24A688
24A689
24A690
24B332
24A687
24A688
24A689
24A690
24B332
24A687
24A688
24A689
24A690
24A687
24A688
24A689
24A687
24A688
24A689
24A687
24A688
24A689

24B544
24B544
24B544
24B544
24B545
24B539
24B539
24B539
24B539
24B539
24B540
24B540
24B540
24B540
24B540
24B544
24B544
24B544
24B539
24B539
24B539
24B540
24B540
24B540

289773
289773
289773
289773
289784
289041
289041
289041
289041
289041
289042
289042
289042
289042
289042
289773
289773
289773
289041
289041
289041
289042
289042
289042

Material Usage
Orifice
Size
in. (mm)

0.020 (0.5)
0.030 (0.8)
0.042 (1.1)
0.055 (1.4)
0.070 (1.8)
0.020 (0.5)
0.030 (0.8)
0.042 (1.1)
0.055 (1.4)
0.070 (1.8)
0.020 (0.5)
0.030 (0.8)
0.042 (1.1)
0.055 (1.4)
0.070 (1.8)
0.030 (0.8)
0.042 (1.1)
0.055 (1.4)
0.030 (0.8)
0.042 (1.1)
0.055 (1.4)
0.030 (0.8)
0.042 (1.1)
0.055 (1.4)

Flow
Viscosity
light
light
light-medium
medium
medium-heavy
light
light
light-medium
medium
medium-heavy
light
light
light-medium
medium
medium-heavy
light
light-medium
medium
light
light-medium
medium
light
light-medium
medium

oz./min. (l/min.)

2–6 (0.06–0.18)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
12–18 (0.36–0.54)
16–20 (0.48–0.60)
2–6 (0.06–0.18)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
12–18 (0.36–0.54)
16–20 (0.48–0.60)
2–6 (0.06–0.18)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
12–18 (0.36–0.54)
16–20 (0.48–0.60)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
12–18 (0.36–0.54)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
12–18 (0.36–0.54)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
12–18 (0.36–0.54)

★With Fluid Control Knob (for fine adjustment of fluid flow).

313516G

5

Selection Charts

High Wear Applications
Includes:

Gun
Assembly
Part No.
24A774✠
24A775✠
24B336✠
24C316✠
24A776✠
24A777✠
24A778✠
24A779✠

Type
Conventional
Conventional
Conventional
Conventional
HVLP
HVLP
Compliant
Compliant

Material Usage

Air Cap
Needle/ Air Cap
Part No.
Nozzle Kit with Pin (without pin,
Part No. Part No. for reference)

24A693
24A694
24B358
24C142
24A695
24A696
24A695
24A696

24B537
24B536
24B536
24B536
24B541
24B542
24B538
24B543

288861
289049
289049
289049
289115
289325
289050
289327

Orifice
Size
in. (mm)

0.059 (1.5)
0.070 (1.8)
0.086 (2.2)
0.110 (2.8)
0.059 (1.5)
0.070 (1.8)
0.059 (1.5)
0.070 (1.8)

Flow
Viscosity
medium
medium-heavy
heavy
heavy
medium
medium-heavy
medium
medium-heavy

oz./min. (l/min.)

12–18 (0.36–0.54)
16–20 (0.48–0.60)
>20 (>0.60)
>25 (>0.74)
12–18 (0.36–0.54)
16–20 (0.48–0.60)
12–18 (0.36–0.54)
16–20 (0.48–0.60)

✠ Needle tip and nozzle exit constructed from tungsten carbide.

Wood Applications
Includes:

Gun
Assembly
Part No.
Type
24A768 Conventional
24A769 Conventional
24A770
HVLP
24A771
HVLP
24A772
Compliant
24A773
Compliant

Air Cap
Needle/ Air Cap
Part No.
Nozzle Kit with Pin (without pin,
Part No. Part No. for reference)

24A691
24A692
24A691
24A692
24A691
24A692

24B533
24B533
24B535
24B535
24B534
24B534

288862
288862
288864
288864
288863
288863

Material Usage
Orifice
Size
in. (mm)

0.030 (0.8)
0.040 (1.0)
0.030 (0.8)
0.040 (1.0)
0.030 (0.8)
0.040 (1.0)

Flow
Viscosity
light
light-medium
light
light-medium
light
light-medium

oz./min. (l/min.)

4–10 (0.12–0.30)
8–14 (0.24–0.42)
4–10 (0.12–0.30)
8–14 (0.24–0.42)
4–10 (0.12–0.30)
8–14 (0.24–0.42)

Gun Selection
HVLP Guns

Compliant Guns

An HVLP gun is a high transfer efficiency gun
that limits the air pressure at the air cap to
10 psi (0.07 MPa, 0.7 bar) maximum. In some
areas, an HVLP gun is required for compliance
with environmental standards. See the Air Cap
chart, page 7, for maximum inlet pressures.

A compliant gun is a high transfer efficiency
gun that has been tested to have a transfer
efficiency greater than or equal to HVLP guns.
In addition, the compliant air cap consumes
much less air than the HVLP air cap. Graco
compliant guns have no restrictions on air cap
pressures. See the Air Cap chart, page 7, for
maximum inlet pressures.

6

313516G

Selection Charts

Conventional Guns
An airspray gun has excellent atomization and
high production rates typically with some
reduction in transfer efficiency.

Proper Needle/Nozzle Selection
The spray gun's needle/nozzle kits range in
size to provide different fluid flow rates. As a
general guideline, use the fluid nozzle that will
give the required flow with the needle fully triggered at a fluid pressure of 5–20 psi
(0.035–0.14 MPa, 0.35–1.4 bar).

•

For low flow rates or light viscosity fluid,
select the smaller nozzle sizes.

•

For high flow rates or high viscosity fluid,
select the larger nozzle sizes.

•

For abrasive fluids, the high wear gun models are recommended.

Air Caps
Air Cap
Part
No.

Type

Application

Nozzle
Orifice
in. (mm)

0.020–0.055
(0.5–1.4)
0.070 (1.8)
0.020–0.070
General Metal (0.5–1.8)
0.020–0.070
General Metal (0.5–1.8)

289773 Conventional General Metal
289784 Conventional General Metal
289041

HVLP

289042

Compliant

288861 Conventional

High Wear

289049 Conventional
289115
HVLP
289325
HVLP
289050 Compliant
289327 Compliant

High Wear
High Wear
High Wear
High Wear
High Wear

288862 Conventional

Wood

288864

HVLP

Wood

288863

Compliant

Wood

313516G

0.059 (1.5)
0.070–0.086
(1.8–2.2)
0.059 (1.5)
0.070 (1.8)
0.059 (1.5)
0.070 (1.8)
0.030–0.040
(0.8–1.0)
0.030–0.040
(0.8–1.0)
0.030–0.040
(0.8–1.0)

Atomizing Air
Fan Air
Max. HVLP/Compliant Max. HVLP/Compliant
Manifold Inlet Pressure Manifold Inlet Pressure
psi (MPa, bar)
psi (MPa, bar)
N/A
N/A

N/A
N/A

17 (0.12, 1.2)

29 (0.20, 2.0)

29 (0.20, 2.0)

33 (0.23, 2.3)

N/A

N/A

N/A
18 (0.12, 1.2)
18 (0.12, 1.2)
28 (0.19, 1.9)
29 (0.20, 2.0)

N/A
28 (0.19, 1.9)
27 (0.19, 1.9)
31 (0.21, 2.1)
32 (0.22, 2.2)

N/A

N/A

24 (0.17, 1.7)

26 (0.18, 1.8)

27 (0.19, 1.9)

42 (0.29, 2.9)

7

Air Flow

Air Flow
See the chart to determine air consumption. Add the air consumption values shown for the atomizing air and fan air pressures to get the total air consumption. For example, air cap 24B544 with
20 psi atomizing air pressure uses 3 scfm atomizing air. A 30 psi fan inlet pressure adds 5 scfm
fan air for a total of 8 scfm air consumption.
Atomizing Air
Air cap

289773

289041

288861

289115

289050

288862

8

Fan Air

Manifold Inlet Pressure Air Flow
psi (MPa, bar)
SCFM
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
17* (0.12, 1.2)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
18* (0.12, 1.2)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
28* (0.19, 1.9)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)

2
3
5
7
8
3
7
10
13
17
6
2
4
6
8
11
3
7
10
14
17
6
1
3
4
5
7
4
2
4
6
7
9

Manifold Inlet Pressure
psi (MPa, bar)

Air Flow
SCFM

10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
29* (0.20, 2.0)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
28* (0.19, 1.9)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
31* (0.21, 2.1)
5 (0.035, 0.35)
10 (0.07, 0.7)
15 (0.10, 1.0)
20 (0.14, 1.4)
25 (0.17, 1.7)

2
4
5
7
9
4
7
11
14
18
10
2
5
7
10
12
4
7
11
15
19
10
2
4
6
8
10
6
1
3
4
5
7

313516G

Air Flow

Atomizing Air
Air cap

288863

289784

289042

289049

289325

289327

288864

Fan Air

Manifold Inlet Pressure Air Flow
psi (MPa, bar)
SCFM
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
27* (0.19, 1.9)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
29* (0.20, 2.0)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
18* (0.12, 1.2)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
29* (0.20, 2.0)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
24* (0.17, 1.7)

Manifold Inlet Pressure
psi (MPa, bar)

Air Flow
SCFM

10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
42* (0.29, 2.9)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
33* (0.23, 2.3)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
27* (0.19, 1.9)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
32* (0.22, 2.2)
10 (0.07, 0.7)
20 (0.14, 1.4)
30 (0.21, 2.1)
40 (0.28, 2.8)
50 (0.34, 3.4)
26* (0.18, 1.8)

3
5
8
11
13
11
2
4
5
7
9
2
4
6
8
10
7
2
4
7
9
11
4
7
11
14
18
10
2
4
6
8
10
7
3
6
10
13
16
8

2
4
5
7
9
5
2
4
6
8
10
2
4
6
8
10
6
1
3
4
6
7
4
7
11
14
18
6
2
4
6
7
9
5
4
7
11
14
18
9

* Maximum HVLP/Compliant inlet manifold pressure.
313516G

9

Installation

Installation
The Automatic AirPro spray gun can spray
most coatings or finishes currently being used
for automotive, industrial, aerospace, marine,
wood, plastic and architectural applications,
while easily operating from paint delivery systems, such as pressure pots or remote pumps
for production line operation.
The air regulator must have a minimum air flow
capacity of 30 scfm at 100 psi (0.7 MPa, 7.0
bar) air pressure.

Ventilate Spray Booth

4. Install the gun on the manifold, using the
four screws (13). Start the threads of all
four screws. Tighten the front two screws
first, and then tighten the back two. Torque
all four screws evenly to 65 in-lb (7.3 N•m).

Non-circulating System
1. See FIG. 1. Apply anti-seize lubricant to the
threads and mating faces of the manifold
(101), plug (109), and elbow (107), supplied unassembled.
2. Install an elbow (107) in one fluid port of
the manifold (101), and a plug (109) in the
other port.
3. Install the internal plug (19) in the gun fluid
port on the same side as the manifold plug.

•

Check and follow all national, state, and
local codes regarding air exhaust velocity
requirements.

•

Check and follow all local safety and fire
codes.

Configure Gun and Manifold
The gun is supplied with an internal fluid plug
and seals (19, 20, 21). To use the gun in a circulating system, remove the internal plug. In a
non-circulating system, leave the plug in place
to minimize flush time.

4. Connect the fluid supply line to the fluid
inlet elbow (107).
5. Install the gun on the manifold, using the
four screws supplied. Start the threads of
all four screws. Tighten the front two
screws first, and then tighten the back two.
Torque all four screws evenly to 65 in-lb
(7.3 N•m).
1

Remove when used in circulating systems.

2

Replace with elbow (107) when used in
circulating systems.

Circulating System

21

1. Apply anti-seize lubricant to the threads
and mating faces of the manifold (101) and
the elbows (107), supplied unassembled.

20
1

19

2. Install the elbows (107) in both fluid ports of
the manifold (101).

107
2

3. Connect the fluid supply line to one elbow
and the fluid return line to the other. The
manifold fluid ports are reversible.

10

101

109

ti8587b

FIG. 1: Non-Circulating Setup Shown (cutaway view)

313516G

Installation

Install Air Fittings
1. Install the supplied 1/4 in. tube fitting into
the cylinder (CYL) air port.
2. Install 3/8 in. tube fittings into the atomization (ATOM) air port and the fan (FAN) air
port.

Ground Air Compressors and
Hydraulic Power Supplies
Ground the air compressors and hydraulic
power supplies according to the manufacturer
recommendations.

Ground Spray Gun
Ground the spray gun by mounting the manifold to a properly grounded reciprocator, robot,
or stationary mount. Check the electrical resistance between the manifold and a true earth
ground. The resistance must be less than 1
megohm.

CYL

ATOM

Ground Fluid Supply Container
Ground the fluid supply container according to
local code.
FAN

Ground Object Being Sprayed
ti8211a

FIG. 2: Air Fittings

Ground System

The following grounding instructions are minimum requirements for a system. Your system
may include other equipment or objects that
must be grounded. Check your local electrical
code for detailed grounding instructions for
your area and type of equipment. Your system
must be connected to a true earth ground.

Ground the object that is being sprayed
according to local code.

Ground Solvent Pails
Ground all solvent pails that are used when
flushing according to local code. Use only
metal pails, which are conductive. Do not place
the pail on a non-conductive surface, such as
paper or cardboard, which interrupts the
grounding continuity.

Ground Pump/Fluid Supply
Ground the pump by connecting a ground wire
and clamp between the fluid supply and a true
earth ground as instructed in your separate
pump instruction manual.

313516G

11

Installation

Mount Gun

Stationary Support

Reciprocating Arm Rod Mount

To mount the gun on a stationary support
(refer to FIG. 4 and to the correct mounting
hole layout for your manifold, pages 38-42):

To mount the gun on a reciprocating arm rod
[0.5 in. (13 mm) diameter maximum]:
1. Insert the mounting bar (A) through the
hole in the manifold as shown in FIG. 3.
NOTE: Use the 1/8 in. alignment pin (P) to
assist in orienting the gun.
2. Secure the gun to the bar by tightening the
mounting screw (B).

1. Align the manifold with the alignment pins.
Locate alignment pins and holes per the
mounting hole layout.
2. Secure the gun to the support with two M5
x 0.8 capscrews (C). The screws must be
long enough to engage the threaded holes
in the gun manifold to a depth of 1/4 in.
(6 mm).

B

P

C

A

ti13588a
ti13587a

FIG. 3: Reciprocating Arm Mount

12

FIG. 4: Stationary Support Mount

313516G

Installation

Retrofit Adapter Plate
The retrofit adapter plate enables the manifold
to be attached to a variety of bolt patterns.
To mount the gun using the retrofit adapter
plate (Kit 288197; See Accessories,
page 34):
1. Mount adapter plate to manifold using the
three screws provided with the kit. (See
FIG. 5 and the mounting hole layout on
page 42.)
2. Bolt plate to mounting surface using four
M5 x 0.8 capscrews. Refer to the correct
mounting hole layout for your manifold,
pages 38-41.

ti13589a

FIG. 5: Retrofit Adapter Plate Mount

313516G

13

Setup

Setup
Connect Air Line

Connect Fluid Hose

NOTE:

NOTE:

•

•

You must install an air pressure regulator (F) on each gun air line to control air
pressure to the gun. See FIG. 6.
• If your regulated air source does not
have a filter, install an air filter (G) on
each air line to ensure a dry, clean air
supply to the gun. Dirt and moisture can
ruin the appearance of your finished
workpiece. See FIG. 6.
• Install a bleed type air shutoff valve (E)
on each gun air supply line, downstream of the gun air regulator, to shut
off air to the gun.
1. For manifolds with a separate ATOM and
FAN port, the gun cylinder, fan, and atomization air must be supplied and regulated
separately. For the manual fan valve manifold, only one supply line is required for
both atomization and fan air.
NOTE: The gun atomizing and fan air inlets
are 3/8 in. O.D. tubing. The cylinder air inlet
accepts 1/4 in. (6.3 mm) O.D. tubing. Use 3/8
in. (9.5 mm) O.D. tubing for fan and atomization air to minimize excessive pressure drop in
the hoses.

Before connecting the fluid line, blow it
out with air and flush it with solvent. Use
solvent that is compatible with the fluid
to be sprayed.
• Install a fluid regulator (L) on the fluid
line to control fluid pressure to the gun.
• Install a fluid shutoff valve (M) to shut off
the fluid supply to the gun.
• Filter the fluid line of coarse particles
and sediment to avoid clogging the fluid
nozzle and causing finishing defects.
Inline fluid filter 24B707 is available.
See Accessories, page 34.
1. Connect the fluid supply hose (J) to the gun
fluid inlet (S), 1/4 npsm thread. See FIG. 8.
2. Connect the other end of the fluid hose (J)
to a regulated fluid supply outlet (M).
3. In a circulating system, connect a
grounded fluid return hose to the gun fluid
outlet (T). See FIG. 8.
In a non-circulating system, remove the
gun fluid outlet fitting (T) and plug the outlet
port with the pipe plug supplied. See FIG. 8.

2. Connect each air hose (D) to a regulated
air supply line (H).

K
L

M
H
J
G

F

E

D

ti01990
ti7016a

FIG. 6: Connect Air Line
FIG. 7: Connect Fluid Hose.
14

313516G

Setup

KEY
N Cylinder Air Inlet: accepts 1/4 in. (6.3 mm) O.D. tubing
P Atomization Air Inlet: 3/8 in, (9.5 mm) O.D. tubing
R Fan Air Inlet: 3/8 in. (9.5 mm) O.D. tubing
S Fluid Inlet: 1/4 npsm
T Fluid Outlet (circulating gun only): 1/4 npsm

Side Mounted Manifold Ports

Flush Spray Gun

Before running any paint through the spray
gun:
1. Flush the gun with a solvent that is compatible with the fluid to be sprayed, using the
lowest possible fluid pressure and a
grounded metal container.

N

T (or S)

S (or T)
FAN

ATOM
CYL

ti8096a

R

P
Bottom Mounted Manifold Ports

2. Perform Pressure Relief Procedure; see
page 18.

Position Air Cap
Air caps are factory-set with the alignment pin
(A) set to a vertical spray pattern. To change
the air cap to a horizontal spray pattern, use a
1/6 in. hex wrench to unscrew the alignment
pin (A) and relocate it to the horizontal spray
pattern hole. When relocating the pin use low
strength thread locker. Torque to 1.5-2.5 in-lb
(0.2-0.3 N•m). Do not overtighten. Refer to
FIG. 9.

N

R

ATOM

FAN
CYL

T (or S)

ti8171a

P

Vertical Pattern

A
S (or T)
Horizontal Pattern
ti8170a

ti8097a

FIG. 8: Manifold Ports

313516G

ti8172a

FIG. 9: Position Air Cap

15

Setup

Adjust Spray Pattern

Do not exceed 100 psi (0.7 MPa, 7 bar)
maximum fluid and air pressure. Higher
pressures can cause parts to rupture and
result in serious injury.
Use the fluid pressure regulator to adjust the
spray gun fluid flow. Some models are
equipped with a fluid control knob to make precise fluid flow adjustments.

L

ti7019a

FIG. 10: Fluid Pressure Regulator
NOTICE

Use caution when operating the fluid control knob near the closed position. The
plastic needle tip may be damaged if
forced too hard against the nozzle seat by
the fluid control knob.
Follow these steps to establish the correct fluid
flow and air flow:
1. To achieve desired flow, adjust the fluid flow
using the fluid pressure regulator (L)
installed in the gun fluid line. Typical industrial flow rates will vary with regulator pressures from 5 to 30 psi (34 to 210 kPa, 0.3 to
2.1 bar). If the fluid pressure is too low at
the desired flow rate, install a smaller nozzle. If the fluid pressure is too high, install a
larger nozzle.
For spray guns equipped with the fluid control knob, you can make flow rate changes
at the spray gun. Rotate the fluid control
knob clockwise to reduce the flow.

16

NOTE: A larger fluid nozzle at a reduced fluid
pressure will maintain the same flow rate, but
the fluid stream (velocity) will slow down.
When air is applied, the lower velocity allows
the air to act on the fluid longer, which
improves atomization.
2. Using the air pressure regulator (F), set the
fan and atomizing air supply pressure per
Table 1. Use these suggested settings as a
starting point.
Table 1: Suggested Starting Settings
Spray Gun

Fan Air (psi)

Atomization
Air (psi)

Conventional

35

35

HVLP

25

25

Compliant

25

25

313516G

Setup

NOTE: HVLP and Compliant Gun Limits
HVLP Guns: local laws may limit the maximum
pressure to 10 psi (70 kPa, 0.7 bar) at the air
cap for compliance. See the table on page 7
for maximum HVLP/Compliant manifold inlet
pressures. To measure pressure at the air cap,
use the appropriate HVLP Pressure Verification Kit. See Accessories, page 34.
Compliant Guns: See the table on page 7 for
maximum HVLP/Compliant manifold inlet pressures.

4. If the spray pattern is too wide or split,
reduce the fan air pressure (or slightly
close the fan adjustment valve on manifold
288223).
To further control the spray pattern of airspray guns only, use an alternate air cap.
For a list of available air caps, refer to
Accessories, page 34.
NOTE: Reducing the fan air pressure to 0 psi
(or fully closing the fan adjustment valve) will
produce a round pattern.

F
ti01997

FIG. 11: Air Pressure Regulator

3. Test the spray pattern atomization while
keeping the gun a consistent distance,
about 6 to 8 inches (150 to 200 mm), from
the test piece.
Check the atomization quality. Increase the
gun atomizing air supply pressure with the
air pressure regulator in 5 psi (34 kPa, 0.3
bar) increments until you obtain the desired
atomization.
NOTE: For the best transfer efficiency, use the
lowest setting needed to achieve desired finish
quality.

313516G

17

Operation

Operation
Pressure Relief Procedure

1. Turn off all bleed type air valves and all
other air and fluid supplies to the gun.
2. Trigger the gun into a grounded metal
waste container to relieve air and fluid pressure.

To achieve best results when applying fluid:
•

Keep gun perpendicular and 6 to 8 in.
(150 to 200 mm) from object being
sprayed.

•

Use smooth, parallel strokes across surface to be sprayed with 50% overlap.

Incorrect

ti8098a

ti8174a

FIG. 12: Pressure Relief

Apply Fluid

Correct

The spray gun has a built-in lead and lag operation. When triggered, the gun begins emitting
air before the fluid is discharged. When the
trigger actuation air is stopped, the fluid stops
before the air flow stops. This helps ensure
that the spray is atomized and prevents fluid
buildup on the air cap and tip.
Adjust the system control device, if it is automatic, so the gun starts spraying just before
meeting the part and stops as soon as the part
has passed.

18

ti8099a

FIG. 13: Correct Spray Method

313516G

Operation

Daily Gun Care

NOTICE

Methylene chloride with formic or propionic acid is not recommended as a flushing or cleaning solvent with this gun as it
will damage aluminum and nylon components.
NOTICE

Solvent left in gun air passages could result in a poor quality paint finish. Do not
use any cleaning method which may allow solvent into the gun air passages.
Do not wipe the gun with a cloth soaked
Do not point the gun up while cleaning it. in solvent; wring out the excess.

ti8100a

Do not immerse the gun in solvent.

ti8101a

313516G

ti4827a

Do not use metal tools to clean the air
cap holes as this may scratch them;
scratches can distort the spray pattern.

ti8175a

19

Operation

General System Maintenance
•

Perform Pressure Relief Procedure,
page 18.

•

Clean the fluid and air line filters daily.

•

Check for any fluid leakage from the gun
and fluid hoses. Tighten fittings or replace
equipment as needed.

•

Flush the gun before changing colors and
whenever you are done operating the gun.

9. Dip the end of a soft-bristle brush into a
compatible solvent. Do not continuously
soak the brush's bristles with solvent and
do not use a wire brush.

ti4845a

Clean and Flush Gun
1. Perform Pressure Relief Procedure,
page 18.

FIG. 14: Use solvent-dipped soft-bristle brush

10. With the gun pointed down, clean the front
of the gun, using the soft-bristle brush and
solvent.

2. Shut off the gun fan and atomizing air.
3. Supply a compatible solvent to the gun fluid
inlet.
4. Point the gun down into a grounded metal
container, and flush the gun with solvent
until all traces of paint are removed from
the gun passages.

11. Scrub the air cap retaining ring, air cap,
and fluid nozzle with the soft-bristle brush
(see FIG. 15). To clean out air cap holes,
use a soft implement, such as a toothpick,
to avoid damaging critical surfaces. Clean
the air cap and fluid nozzle daily, minimum.
Some applications require more frequent
cleaning.

5. Perform Pressure Relief Procedure,
page 18.
6. Disconnect the solvent supply.
7. Remove the air cap retaining ring and air
cap. Remove the nozzle, if necessary.
NOTICE

Trigger the gun or remove the piston cap if
you remove the nozzle for cleaning. This
keeps the needle seat away from the nozzle seating surface and prevents the seat
from being damaged.
8. Clean the air cap retaining ring, air cap,
and fluid nozzle with solvent.

20

ti8176a

FIG. 15: Clean air cap, ring and fluid nozzle

12. Install the air cap retaining ring and air cap.
13. Dampen a soft cloth with solvent and wring
out the excess. Point the gun down and
wipe off the outside of the gun.

313516G

Troubleshooting

Troubleshooting
Some improper patterns are caused by the
improper balance between air and fluid. Refer
to Spray Pattern Troubleshooting, page 22.
NOTE: Check all possible remedies in the troubleshooting charts before disassembling the
gun.

General Troubleshooting
Problem

Cause

Fluid leakage through venting
Worn packing (17) or needle (5).
holes.
Air leakage through venting hole. Worn o-ring (9) or gasket (15).
Air leakage from back of gun.
Air does not trigger.

Replace packing or needle.

Check and replace parts as
needed.
Worn o-rings (8, 9).
Replace o-rings.
Piston stem is disconnected from Replace piston assembly.
main body of piston assembly (3).
Cylinder air pressure is too low.

Air does not shut off.

Solution

Piston assembly not seating
properly.

Increase cylinder air pressure to
50 psi.
Clean/service piston assembly.
Replace worn or swollen o-rings.

Broken return spring (7).

Replace return spring.

Swollen o-ring (8).

Replace o-rings.

Worn piston stem o-rings (10, 11). Replace o-rings.

Fluid leakage from front of gun.

Bottom gasket (12) failed.
Replace gasket.
Fluid needle tip (5a) is dirty, worn, Clean or replace fluid needle tip or
or damaged.
entire needle (5).

Fluid is present at air cap holes.

Dirty or worn nozzle (23).
Clean or replace nozzle.
Nozzle (23) is insufficiently tight- Tighten or replace o-ring.
ened or sealing o-ring (36) is damaged.

313516G

21

Troubleshooting

Problem
Fluid needle will not trigger.

Cause

Solution

Loose or missing fluid needle stop Replace stop or tighten setscrew.
(29) or setscrew (30).
Air leaking around piston (3).

Replace o-ring (8) or piston.

Swollen piston o-ring (8).

Replace o-ring. Do not immerse
piston in solvent.

Insufficient air pressure on trigger. Increase air pressure or clean air
line.

Fluid does not shut off.

Plug (19) is in incorrect fluid port. Move plug to fluid port consistent
with manifold plumbing, unless
you are using gun in a circulating
system. If you are, all fluid ports in
gun and on manifold should be
open.
Worn o-ring (11) or (9).
Replace o-ring.
Piston cap (4) not fully tightened. Tighten piston cap until it bottoms
out.
Spring (6) not in place.

Check spring position.

Swollen piston o-ring (8).

Replace o-ring. Do not immerse
piston in solvent.

Spray Pattern Troubleshooting
Problem

Cause

Fluid flow is fluttering while spray- Fluid nozzle is not tight enough.
ing.
O-ring (36) is missing or damaged.
Fluid filter is clogged.
Fluid pressure is too low, causing
fluid flow to reduce when gun is
elevated.
Pattern becomes off-set or heavy Air cap horn holes plugged or
on ends.
damaged.

Fluid flow fades while spraying
high viscosity fluids.

Solution
Tighten fluid nozzle to 60 in-lb
(6.8 N•m).
Replace o-ring.
Check fluid filter.
Raise fluid pressure at source or
use a smaller fluid nozzle.

Clean air cap horn holes with
non-metallic item such as a toothpick, or replace air cap.
Gun fluid pressure is too high with Using needle/nozzle kit with too
Use needle/nozzle kit with larger
gun triggered.
small orifice.
orifice.
Fluid system will not operate at
There is no fluid regulator, or air Add low pressure fluid regulator,
low enough fluid pressure [below regulator on pressure pot is not
or add more sensitive low pres10 psi (70 kPa, 0.7 bar)].
sensitive enough at low pressures. sure air regulator on pressure pot.

22

313516G

Service

Service
7. Check the fluid needle (5) for damage or
excessive wear. Replace the needle tip (5a)
or the entire needle if necessary.
NOTE: Air Section Repair Kit 288171 and
Fluid Section Repair Kit 24B675 are available
for purchase separately. Numbers in parenthesis in the text refer to the reference numbers in
the figures and in the parts list.

8. Remove nozzle (23). Check nozzle and
o-ring (36) for damage.

Disassembly
1. Perform Pressure Relief Procedure,
page 18.
2. Unscrew the four screws (13) and remove
the gun from the manifold.
3. Remove the air cap retainer (25) and air
cap (24).

13

4

36
ti8198a

FIG. 17

9. Remove the piston. Using a pliers, pull the
piston (3) out of the piston housing (1).
10. Unscrew the two screws (14) and separate
the fluid housing (2) and the piston housing
(1). Remove gasket (12) only if it needs to
be replaced.

23
24, 25

29 7

6

14
ti13590a

2

FIG. 16

3

4. Remove the piston cap (4) from the piston
housing (1). Remove the springs (6, 7).
5. Using a 1/16 in. hex wrench loosen the fluid
needle set screw (30). Remove the needle
stop (29).
6. Pull the fluid needle (5) out of the back of
the gun.

313516G

1

30

ti13591a

FIG. 18

11. Remove the packing nut (16) with a
wrench.
12. Remove the fluid packing (17) from the nut
(16). Discard the old fluid packing.
23

Service

13. Remove all o-rings from the piston (3) and
stems (T). Check that the stems are solidly
in place. If they are loose, replace the entire
piston assembly (3).

o-ring (21) and backup (20) from the
plug. See FIG. 21.
b. Circulating guns: Remove the gasket
(22) from the fluid housing (2). See FIG.
21.

14. Perform the following applicable step:
a. Non-circulating guns: Remove the fluid
outlet port plug (19), and gasket (22)
from the fluid housing (2). Remove the
Cutaway View:
Part No. 24A749 Gun Shown

15. Clean all parts and replace any worn parts.
When assembling, lubricate the threads
with anti-seize lubricant.
T

1

2

10* 3

8* 3

4

2

4

11* 3
6

25
24

23

1

2

16

2

8

7

2

30
9

46
5a

9

5

36 45 (x 2)

3 10

3

3

6

7

29

3

12*

ti13592b

3

SERVICE NOTES:
1 Torque to 35-45 in-lb (4.0-5.1 N•m).

ti8199a

2

Lubricate threads with anti-seize lubricant.

3

Lubricate with light-weight oil.

4

Tighten cap (4) until it bottoms out.

6

Apply semi-permanent anaerobic sealant.

7

Torque to 6.5-7.5 in-lb (0.73-0.85 N•m).

8

Torque to 95-105 in-lb (10.7-11.8 N•m).

9

Apply semi-permanent anaerobic sealant to two
threads at end of needle shaft.

10

Step in spacer (46) must face into packing nut.

Alternate Fluid Control Shown

FIG. 19
24

313516G

Service

Reassembly
1. Non-circulating guns only: Lubricate the
backup ring (20†) and o-ring (21†) and
install them on the fluid outlet port plug
(19). Install the plug in the fluid outlet port
of the fluid housing (2). See FIG. 21.
2. All guns: Reinstall the gasket (22) in the
fluid housing (2).
3. Install the o-rings (8*, 9*) on the piston (3).
Install the two o-rings (10*, 11*) on each of
the piston stems (T). Lubricate all the
o-rings, the piston, and the piston stems.
4. Remove the protective paper from the
sticky side of the gasket (12*) and adhere
the gasket to the bottom of the piston housing (1), making sure the three holes in the
gasket are properly aligned with the matching holes in the housing.
5. Lubricate the washers (45†) and spacer
(46†). Insert them into the packing nut (16)
as shown in FIG. 20, The step on the
spacer faces into the packing nut.

45

46

45

Torque the two screws (14) to 35-45 in-lb
(4.0-5.1 N•m).
a. Insert the piston (3) into the piston
housing (1).
b. Ensure nozzle sealing o-ring (36) is
installed on nozzle (23).
8. To avoid galling of the fluid nozzle seat in
the fluid housing, apply a thin film of lubricant to the threads. Install the nozzle into
the fluid housing. Torque the nozzle
securely to 35-45 in-lb (4.0-5.1 N•m).
NOTE: If you are replacing the needle tip (5a),
apply semi-permanent anaerobic sealant to
two threads at the end of the needle shaft.
Assemble the needle tip to the shaft and hand
tighten. Allow adequate time for the sealant to
cure before installing the needle assembly into
the gun.
9. Lubricate and install the needle (5) into the
back of the gun assembly. Push it straight
in through the piston.
10. Install the needle stop (29) on the needle.
Coat the setscrew (30) with semi-permanent anaerobic sealant and install the
screw into the needle stop. Torque to
6.5-7.5 in-lb (0.73-0.85 N•m). Pull on the
needle to make sure it seats fully.

16

11. Install the springs (6, 7).
ti17603a

FIG. 20. Fluid packings

12. Lubricate the threads of the piston housing
(1). Screw the cap (4) onto the housing
until it bottoms out.

6. Insert the packing nut into the fluid housing
(2) and torque to 95-105 in-lb (10.7-11.8
N•m).

13. Install the air cap (24) and air cap retainer
(25).

7. Align the gasket (15*) as shown in the
exploded view in FIG. 21. Place the gasket
on the piston housing (1), then install the
fluid housing (2) onto the piston housing.

14. Reinstall the gun on the manifold using the
four screws (13). Start the threads of all
four screws. Tighten the front two screws
first, and then tighten the back two. Torque
all four screws evenly to 65 in-lb (7.3 N•m).

313516G

25

Parts

.Parts

Parts
Part No. 24A749 Gun Shown

11

2

13

3

45

16

15*

8

2

5
5a
23

1

46

9

21†

2

24
10

3

20† 3

19

10

3

Alternate Fluid
Control

10

4

39
22†

25

12

4

36†
24a
T
11* 3

25a

10* 3
6
7
29
9* 3

12*

3

3

8* 3

30

6

7

ti13593b

1

2

13

11

14

1

1

SERVICE NOTES:
Torque to 35-45 in-lb (4.0-5.1 N•m).

2

Lubricate threads with anti-seize lubricant.

3

Lubricate with light-weight oil.

4

Tighten cap (4) until it bottoms out.

6

Apply semi-permanent anaerobic sealant.

7

Torque to 6.5-7.5 in-lb (0.73-0.85 N•m).

8

Torque to 95-105 in-lb (10.7-11.8 N•m).

9

Apply semi-permanent anaerobic sealant to two threads at end of needle shaft.

10

Used on non-circulating guns only.

11

Torque to 65 in-lb (7.3 N•m).

12

Step in spacer (46) must face into packing nut.

FIG. 21

26

313516G

Parts

Ref. Part

Description

1
2
3
4
5
5a
6

----24B676
240895
See pages 28-29
See pages 28-29
See pages 28-29
114139

7

114138

8*

115066

9*

111450

HOUSING, piston
HOUSING, fluid
PISTON, assembly
CAP, piston
NEEDLE, assembly
TIP, needle
SPRING, compression
SPRING, compression
O-RING, fluoroelastomer
O-RING, fluoroelastomer
O-RING, fluoroelastomer
O-RING, fluoroelastomer
GASKET,
polyethylene (bottom)
SCREW, mounting
manifold (M5)
SCREW, SHC
GASKET, polyethylene (front)
NUT, packing
PLUG, fluid
RING, back-up, PTFE
O-RING, fluoroelastomer

10* 111504
11* 112319
12* 114134
13

15H317

14 15H318
15* 15H316
16
19
20†
21†

195222
192687
114340
114244

313516G

Qty.
1
1
1
1
1
1
1
1
1
1
2
2
1
4
2
1
1
1
1
1

Ref. Part

Description

Qty.

22† 192443
GASKET, fluid
23 See pages 28-29 NOZZLE, fluid,
0.030 in.
24 See pages 28-29 CAP, air
24a 24B546
PIN, locating,
threaded; (pack of 10)
25 289079
RETAINER, ring,
assembly
25a 289791
SEAL KIT, air cap
(5 of each)
----O-RING, PTFE
----WASHER, UHMW
29 192452
STOP, needle
30 114137
SCREW, set
34 114141
WRENCH, hex, not
shown
36† 111457
O-RING
38 ----PIN, dowel, not
shown
39 15H702
INSERT, plastic
40▲ 15K759
LABEL, warning, not
shown
45† ----WASHER, UHMWPE
46† ----SPACER, stainless
steel

2
1
1
1
1

5
5
1
1
1
1
1
1
1
2
1

* Included in Air Seal Repair Kit 288171.
† Included in Fluid Seal Repair Kit 24B675.
----- Not sold separately.
▲Replacement Warning labels, signs, tags, and
cards are available at no cost.

27

Repair Kits

Repair Kits
NOTE: Alternate nozzle sizes are also available. See Accessories, page 34.

General Metal Applications
Item 5
Needle
Assembly

5 and 23)

Cap

(Includes
Needle Tip)

Item 24
Item 5a
Air Cap Air Cap
Needle
(Includes (without
Item 23 locating locating
Tip
(Pack of 5) Nozzle
pin)
pin)

24B333 Conventional 0.020 (0.5)
24A747 Conventional 0.030 (0.8)

24B332

192453

24B331

289350 289061 24B544 289773

24A687

192453

24A683

288183 289062 24B544 289773

24A748 Conventional 0.042 (1.1)
24A749 Conventional 0.055 (1.4)

24A688

192453

24A684

288184 289063 24B544 289773

24A689

192453

24A685

288185 289064 24B544 289773

24A750 Conventional 0.070 (1.8)
24B334
0.020 (0.5)
HVLP

24A690

192453

24A685

288185 289065 24B545 289784

24B332

192453

24B331

289350 289061 24B539 289041

24A754

HVLP

0.030 (0.8)

24A687

192453

24A683

288183 289062 24B539 289041

24A755

HVLP

0.042 (1.1)

24A688

192453

24A684

288184 289063 24B539 289041

24A756

HVLP

0.055 (1.4)

24A689

192453

24A685

288185 289064 24B539 289041

24A757

HVLP

0.070 (1.8)

24A690

192453

24A685

288185 289065 24B539 289041

24B335

Compliant

0.020 (0.5)

24B332

192453

24B331

289350 289061 24B540 289042

24A761

Compliant

0.030 (0.8)

24A687

192453

24A683

288183 289062 24B540 289042

24A762

Compliant

0.042 (1.1)

24A688

192453

24A684

288184 289063 24B540 289042

24A763

Compliant

0.055 (1.4)

24A689

192453

24A685

288185 289064 24B540 289042

24A764

Compliant

0.070 (1.8)

24A690

192453

24A685

288185 289065 24B540 289042

24A751★ Conventional 0.030 (0.8)
24A752★ Conventional 0.042 (1.1)

24A687

24A512

24A683

288183 289062 24B544 289773

24A688

24A512

24A684

288184 289063 24B544 289773

24A753★ Conventional 0.055 (1.4)
24A758★
0.030 (0.8)
HVLP

24A689

24A512

24A685

288185 289064 24B544 289773

24A687

24A512

24A683

288183 289062 24B539 289041

24A759★

HVLP

0.042 (1.1)

24A688

24A512

24A684

288184 289063 24B539 289041

24A760★

HVLP

0.055 (1.4)

24A689

24A512

24A685

288185 289064 24B539 289041

24A765★

Compliant

0.030 (0.8)

24A687

24A512

24A683

288183 289062 24B540 289042

24A766★

Compliant

0.042 (1.1)

24A688

24A512

24A684

288184 289063 24B540 289042

24A767★

Compliant

0.055 (1.4)

24A689

24A512

24A685

288185 289064 24B540 289042

Gun Part
Number Spray Type

28

Nozzle Needle/Nozzle
Orifice
Item 4
Kit
Size
(Includes Items Piston
in. (mm)

313516G

Repair Kits

High Wear Applications

Gun Part
Number Spray Type

Nozzle Needle/Nozzle
Orifice
Item 4
Kit
Size
Piston
(Includes Items

Item 5
Needle
Assembly

Item 24
Item 5a
Air Cap Air Cap
Needle
(Includes (without
Item 23 locating locating
Tip
(Pack of 5) Nozzle
pin)
pin)

5 and 23)

Cap

(Includes
Needle Tip)

24A774✠ Conventional 0.059 (1.5)
24A775✠ Conventional 0.070 (1.8)

24A693

192453

24A686

N/A

289074 24B537 288861

24A694

192453

24A686

N/A

289075 24B536 289049

24B336✠ Conventional 0.086 (2.2)
24C316✠ Conventional 0.110 (2.8)

24B358

192453

24B357

N/A

289076 24B536 289049

24C142

192453

24C319

N/A

289975 24B536 289049

24A776✠

HVLP

0.059 (1.5)

24A695

192453

24A686

N/A

289331 24B541 289115

24A777✠

HVLP

0.070 (1.8)

24A696

192453

24A686

N/A

289332 24B542 289325

24A778✠

Compliant

0.059 (1.5)

24A695

192453

24A686

N/A

289331 24B538 289050

24A779✠

Compliant

0.070 (1.8)

24A696

192453

24A686

N/A

289332 24B543 289327

in. (mm)

Wood Applications
Item 5
Needle
Assembly

5 and 23)

Cap

(Includes
Needle Tip)

Item 24
Item 5a
Air Cap Air Cap
Needle
(Includes (without
Item 23 locating locating
Tip
(Pack of 5) Nozzle
pin)
pin)

24A768 Conventional 0.030 (0.8)
24A769 Conventional 0.040 (1.0)

24A691

192453

24A683

288183 288927 24B533 288862

24A692

192453

24A684

288184 289112 24B533 288862

24A770

HVLP

0.030 (0.8)

24A691

192453

24A683

288183 288927 24B535 288864

24A771

HVLP

0.040 (1.0)

24A692

192453

24A684

288184 289112 24B535 288864

24A772

Compliant

0.030 (0.8)

24A691

192453

24A683

288183 288927 24B534 288863

24A773

Compliant

0.040 (1.0)

24A692

192453

24A684

288184 289112 24B534 288863

Gun Part
Number Spray Type

Nozzle Needle/Nozzle
Orifice
Item 4
Kit
Size
(Includes Items Piston
in. (mm)

★Model has Fluid Control Knob (for fine adjustment of fluid flow).
✠ Needle tip and nozzle exit constructed from tungsten carbide.

313516G

29

Repair Kits

Part No. 288221
Manifold with bottom fluid ports
Ref. Part
No. No.
101

-----

103

120388

105

114246

107

166846

108

120389

109❄ 101970

114

120453

Description

Qty.

MANIFOLD, bottom fluid
ports
FITTING, tube, air inlet;
1/4 in. OD tube x 1/8 npt(m)
SCREW, set; 5/16,
0.437 in. long
NIPPLE, SST; 1/4 npsm,
straight pipe thread x 1/4 npt
FITTING, tube, air line;
3/8 in.OD tube x 1/4 npt
PLUG, pipe, SST; 1/4-18 ptf,
supplied to plug fluid outlet
port in non-circulating applications
SCREW, SHCS, M3 x 18

1
1
1
2
2
1

1

❄ Not shown.
----- Not sold separately.
1

Apply anti-seize lubricant to threads and mating
faces of manifold (101) and any fittings and/or plugs
used in fluid ports.

101

114

103

107

1

105

108
ti9398c

FIG. 22: Manifold with Bottom Fluid Ports

30

313516G

Repair Kits

Part No. 288223
North America Low Pressure Manifold with
side fluid ports and fan adjustment valve

1

Apply anti-seize lubricant to threads and mating
faces of manifold (101) and any fittings and/or plugs
used in fluid ports.

2

Install with valve turned fully counterclockwise to
outermost position.

3

Torque to 125-135 in-lb (14-15 N•m).

Part No. 24C342
International Low Pressure Manifold with side
fluid ports and fan adjustment valve

108
114

Ref.
No.

101
102
103

Part No.

Description

----243949

MANIFOLD, fan adjustable
VALVE, fan, assy.
FITTING, tube, air inlet;
120388✠
1/4 in. OD tube x 1/8 npt(m)
120538◆
6 mm OD tube x 1/8 npt(m)
104
FITTING, tube, air line;
120389✠
3/8 in.OD tube x 1/4 npt
120537◆
8 mm OD tube x 1/4 npt
15D916◆❄ 4 mm OD tube x 1/4 npt;
shipped loose
107 114246
SCREW, set; 5/16;0.437 in.
long
108
ELBOW, male
114342✠
1/4 - 18 npt
114247◆
#5JIC x 1/4-18 npt
109❄ 101970
PLUG, pipe, SST; 1/4-18
ptf, supplied to plug fluid
outlet port in non-circulating applications
114 120453
SCREW, SCHS, M3 x 18

Qty.
1

108

1

1

104

1

1

102
1

101

2
3

107

103
ti0556c

FIG. 23: Side Fluid Ports and Fan Adjustment Valve

2

1

1

❄ Not shown, optional size
----- Not sold separately.
✠ Part No. 288223 only.
◆ Part No. 24C342 only.

313516G

31

Repair Kits

Part No. 288217
North America Manifold with side fluid ports
Part No. 288218
1

International Manifold with side fluid ports
Ref.
No. Part No.

Description

1

FITTING, tube, air line
3/8 in.OD tube x 1/4
120389❖
npt
8 mm OD tube x 1/4
120537◆
npt
4 mm OD tube X 1/4
15D916◆❄
npt; shipped loose
109❄ 101970
PLUG, pipe, SST; 1/4-18
ptf, supplied to plug fluid
outlet port in non-circulating applications
114 120453
SCREW, SHCS, M3 x 18

2

-----

103
120388❖
120538◆
105

114246

107
114342❖
114247◆
108

107

Qty.

MANIFOLD, side fluid
ports
FITTING, tube, air inlet
1/4 in. OD tube x 1/8
npt(m)
6 mm OD tube x 1/8
npt(m)
SCREW, set; 5/16;
0.437 in. long
ELBOW, male, 1/4-18 npt
#5 JIC x 1/4-18 npt

101

Apply anti-seize lubricant to threads and mating
faces of manifold (101) and any fittings and/or plugs
used in fluid ports.

101

114

1

103

1
1

2

107

105

108
ti8148c

FIG. 24: Manifold with Side Fluid Ports

1

1

❄ Not shown, optional size.
----- Not sold separately.
❖ Part No. 288217 only.
◆ Part No. 288218 only.

32

313516G

Repair Kits

Part No. 288160
Rear Port Manifold, North America
Part No. 288211
Rear Port Manifold, International

1

Apply sealant to threads and mating faces of
manifold (101) and any fittings and/or plugs used in
fluid ports.

Ref.
No. Part No.

2

Torque to 8-10 in-lb (0.9–1.3 N•m).

101 ----103
15H521❖
15J003◆
105 116475
106 120353
107 15J077
110 114246
111
120389❖
120537◆
15D916◆❄
112
120388❖
120538◆
113 103253

Description

MANIFOLD, aluminum
FITTING, fluid path
1/4 npsm
#5 JIC
SCREW, SHCS, M4 x 12
O-RING, PTFE
O-RING, PTFE
SCREW, set, hex soc
FITTING, tube, air line
3/8 in. OD tube x 1/4 npt
8 mm OD tube x 1/4 npt
4 mm OD tube x 1/4
npt; shipped loose
FITTING, tube, air inlet
1/4 in. OD tube x
1/8 npt(m)
6 mm OD tube x
1/8 npt(m)
SCREW, set

Qty.
1

3

Torque to 110-130 in-lb (12.3–4.7 N•m).

107

2

105

106

2

103

1

2

3

2
2
1
2

2

113

1

112

1

111

1

101
110

ti8200a

2

FIG. 25: Manifold with Rear Fluid Ports

❄ Not shown, optional size.
----- Not sold separately
❖ Part No. 288160 only.
◆ Part No. 288211 only.

313516G

33

Accessories

Accessories
Alternate Nozzle Sizes

Gun Type
Conventional
Conventional
HVLP
HVLP
Compliant
Compliant
Conventional
HVLP
Compliant

Nozzle
Orifice
in. (mm)

(without locating
pin)

Nozzle

0.086 (2.2)
0.110 (2.8)
0.086 (2.2)
0.110 (2.8)
0.086 (2.2)
0.110 (2.8)
0.020 (0.5)
0.020 (0.5)
0.020 (0.5)

289068
289069
289070
289043
289044
289045
288862
288864
288863

289066
289067
289066
289067
289066
289067
288907
288907
288907

Application

General Metal

Wood

Air Cap

Needle
Tip
(Qty. 5)

289004
289007
289004
289007
289004
289007
289350
289350
289350

Stainless Steel Air Cap Kits
Gun Type
Conventional
Conventional
HVLP
Compliant

Application

Air Cap

Nozzle Orifice
in. (mm)

0.020-0.055 (0.5-1.4)
0.070 (1.8)
General Metal
0.020-0.070 (0.5-1.8)
0.020-0.070 (0.5-1.8)

Cleaning Brush 105749
For use in cleaning gun.

Lubricant 111265
One 4 oz. (113 gram) tube sanitary (non-silicone) lubricant for fluid seals and wear areas.

Replacement Gun 24A780
Gun without needle, nozzle, and air cap.

Fluid Control Knob Repair Kit 288138

Air Cap

(without
locating pin)

(with Locating Pin)

24B671
24B672
24B669
24B670

24B667
24B668
24B665
24B666

Fluid Hose Parts Breakdown
Part No.

Description

239629

FITTING, assy, swivel

061345

TUBING, 1000 ft. (305 m) roll

Retrofit Adapter Plate 288197
The retrofit adapter plate enables the manifold
to be attached to a variety of bolt patterns. See
page 13 and page 42.

Includes spring, ball, and retaining clip.

Gun Mounting Bracket (Cefla) Kit
24B609

Zero Cavity Needle Tip 24G618

Includes bracket and screw.

1.1 mm needle tip, pack of 5.

34

313516G

Accessories

HVLP Pressure Verification Kit

Inline Fluid Filter 24B707

For use in checking air cap atomizing and fan
pattern air pressure at various supply air pressures. Not to be used for actual spraying.

Filter is removable without disconnecting the
fluid line. Includes housing, o-ring, and
0.005 in. tip filter (equivalent to 100 mesh
screen).

Install the kit air cap on the gun. Turn on the air
to the gun, then trigger the gun and read the
air pressure on the gauge.
NOTE: To be “HVLP compliant,” the atomizing
and fan pattern air pressure must not exceed
10 psi (70 kPa, 0.7 bar).
Part No.

Description

289563

HVLP General Metal

289568

HVLP High Wear 0.059 in. (1.5 mm)

289569

HVLP High Wear 0.070 in. (1.8 mm)

289566

HVLP Wood

Spray Tip Filters
Final filter to prevent foreign particles from
ruining sprayed surface smoothness.
25-Count
Carton
3-Pack
238562

238561

238564

238563

Description
0.005 in. (equivalent to 100
mesh screen)
0.009 in. (equivalent to 60
mesh screen)

Tips
Part No. Description
24E484

0.030 in. SST Needle Tips (Pack of 5)

ti13594a

FIG. 26: HVLP Pressure Verification Kit

313516G

35

Dimensions

Dimensions
Manifold Models 288217 or 288218, All Gun Models
2.0 in.
(50.8 mm)

5.3 in. (134.6 mm)
6.4 in. (162.6 mm) with fluid control knob

1.4 in.
(35.6 mm)

3.0 in.
(76.2 mm)

0.5 in. (12.7 mm)
mounting hole

3.9 in.
(99.1 mm)

2.8 in.
(71.1 mm)

ti13880a

ti13879a

FIG. 27

Manifold Model 288221, All Gun Models
2.0 in.
(50.8 mm)

5.3 in. (134.6 mm)
6.4 in. (162.6 mm) with fluid control knob

1.4 in.
(35.6 mm)

3.7 in.
(94.0 mm)

1.9 in.
(48.3 mm)

ti13882a

0.5 in. (12.7 mm)
mounting hole

2.7 in.
(68.6 mm)
ti13881a

FIG. 28

36

313516G

Dimensions

Manifold Model 288223 or 24C342, All Gun Models
2.0 in.
(50.8 mm)

5.3 in. (134.6 mm)
6.4 in. (162.6 mm) with fluid control knob

1.4 in.
(35.6 mm)

3.0 in.
(76.2 mm)

0.5 in. (12.7 mm)
mounting hole

3.8 in.
(96.5 mm)

2.7 in.
(68.6 mm)

ti13884a

ti13883a

FIG. 29

Manifold Model 288160 or 288211, All Gun Models
2.0 in.
(50.8 mm)

5.3 in. (134.6 mm)
6.4 in. (162.6 mm) with fluid control knob

3.4 in.
(86.4 mm)

1.8 in.
(45.7 mm)

ti13886a

1.8 in.
(45.7 mm)

0.375 in. (95 mm)
mounting hole

2.7 in.
(68.6 mm)
ti13881a

FIG. 30

313516G

37

Mounting Hole Layouts

Mounting Hole Layouts
Manifold Models 288217 or 288218, All Gun Models

0.16 in.
(4.1 mm)

0.92 in.
(23.4 mm)

0.4 in.
(10.2 mm)

Two M5 x 0.8 x 0.25 in.
(6.3 mm) holes

1.75 in.
(44.4 mm)
1.375 in.
(34.9 mm)

Two 0.13 diameter x
0.31 in. (7.8 mm)
holes. Use 1/8 in. pin
for alignment

1.5 in.
(38.1 mm)

ti13887a

2.1 in.
(53.3 mm)

0.5 in. (12.7 mm)
mounting hole

ti13879a

FIG. 31

38

313516G

Mounting Hole Layouts

Manifold Model 288221, All Gun Models

0.18 in.
(4.6 mm)

0.92 in.
(23.4 mm)

0.4 in.
(10.2 mm)

Two M5 x 0.8 x 0.25 in.
(6.3 mm) holes

1.75 in.
(44.4 mm)
1.375 in.
(34.9 mm)

2.1 in.
(53.3 mm)

Two 0.13 diameter x
0.31 in. (7.8 mm)
holes. Use 1/8 in. pin
for alignment

ti13888a

2.8 in.
(71.1 mm)

0.50 in. (12.7 mm)
mounting hole

ti13881a

FIG. 32

313516G

39

Mounting Hole Layouts

Manifold Model 288223 or 24C342, All Gun Models

0.216 in.
(5.5 mm)

2.0 in.
(50.8 mm)

Four M6 x 1.0 x 0.34 in.
(6.3 mm) holes

0.225 in.
(5.7 mm)

1.3 in.
(33 mm)

1.75 in.
(44.4 mm)

ti13889a

3.0 in.
(76.2 mm)

2.1 in.
(53.3 mm)

0.5 in. (12.7mm)
mounting hole
ti13879a

FIG. 33

40

313516G

Mounting Hole Layouts

Manifold Model 288160 or 288211, All Gun Models

0.92 in.
(23.4 mm)

0.4 in.
(10.2 mm)

Two M5 x 0.8 x 0.25 in.
(6.3 mm) holes

0.19 in.
(4.8mm)

1.75 in.
1.375 in. (44.4 mm
(34.9 mm

1.1 in.
(27.9 mm)

Two 0.13 diameter x
0.31 in. (7.8 mm)
holes. Use 1/8 in. pin
for alignment
ti13890a

2.3 in.
(58.4 mm)

0.375 in. (9.5 mm)
mounting hole
ti13885a

FIG. 34
313516G

41

Mounting Hole Layouts

Retrofit Adapter Plate 288197
For use with manifold models 288217, 288218, 288221, 288216, and 288211
2.0 in.
(51 mm)

1.4 in.
(34.9 mm)

0.74 in.
(18.7 mm)

ti8178a

2.3 in.
(57.7 mm)

ti13600a

FIG. 35

42

313516G

Technical Data

Technical Data
Maximum Working Fluid Pressure . . . . . . . . . . . . . . . . . . .
Maximum Working Air Pressure. . . . . . . . . . . . . . . . . . . . .
Maximum HVLP and Compliant Gun
Inbound Air Pressure . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum Working Fluid Temperature . . . . . . . . . . . . . . . .
Minimum Air Cylinder Actuation Pressure . . . . . . . . . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted Parts
Models 24B333-24B335 and 24A747-24A773 . . . . . . .

100 psi (0.7 MPa, 7 bar)
100 psi (0.7 MPa, 7 bar)
See chart on page 7.
120° F (49° C)
50 psi (0.34 MPa, 3.4 bar)
1.5 lbs (680 g)

Stainless Steel, Ultra High Molecular
Weight Polyethylene, Acetal, PTFE,
PEEK
Models 24A774-24A779 . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel, Ultra High Molecular
Weight Polyethylene, Acetal, PTFE,
Tungsten Carbide

Triggering Speed
These values apply to a new gun with a 12 ft. (3.6 m), 1/4 in. (6.3 mm) OD cylinder air line and a
0.055 in. nozzle. These values will vary slightly with use and with variations in equipment.
Cylinder Air
Pressure

Fluid Pressure

Air Pressure

psi (kPa, bar)

psi (kPa, bar)

psi (kPa, bar)

msec to fully
open

msec to fully
close

50 (0.35, 3.5)

50 (0.35, 3.5)

100 (0.7, 7.0)

58.4

50.4

Sound Data
Conventional
Measured at 44 psi (0.30 MPa, 3.0 bar) atomizing air and
47 psi (0.32 MPa, 3.2 bar) fan air pressure
Sound Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HVLP
Measured at 17 psi (0.12 MPa, 1.2 bar) atomizing air
and 29 psi (0.20 MPa, 2.0 bar) fan air pressure
Sound Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compliant
Measured at 29 psi (0.20 MPa, 2.0 bar) atomizing air and
33 psi (0.23 MPa, 2.3 bar) fan air pressure
Sound Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

88.82 dBa
78.91 dBa

89.70 dBa
79.79 dBa

87.47 dBa
77.56 dBa

Sound power measured per ISO 9614-2.

313516G

43

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 313516

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revised 01/2012



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Marked                          : True
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Copyright                       : 2009, Rev. G 01/2012
Job Ref                         : Z070224
Web Statement                   : 313516, Automatic AirPro Spray Guns
Keywords                        : 313516, Automatic AirPro Spray Guns, 24B333, 24B334, 24B335, 24A747, 24A748, 24A749, 24A750, 24A751, 24A752, 24A753, 24A754, 24A755, 24A756, 24A757, 24A758, 24A759, 24A760, 24A761, 24A762, 24A763, 24A764, 24A765, 24A766, 24A767, 24A774, 24A775, 24A776, 24A777, 24A778, 24A779, 24B336, 24C316, 24A768, 24A769, 24A770, 24A771, 24A772, 24A773
Modify Date                     : 2013:09:24 09:05:10-05:00
Creator Tool                    : FrameMaker 9.0
Create Date                     : 2005:04:27 11:19:54Z
Metadata Date                   : 2013:09:24 09:05:10-05:00
Format                          : application/pdf
Description                     : 313516, Automatic AirPro Spray Guns
Title                           : 313516G - Automatic AirPro Spray Guns, Instructions-Parts, English
Creator                         : Ryan Stellmaker
Document ID                     : uuid:53a9ca6b-feb8-40e6-ada6-d41c34bb1360
Instance ID                     : uuid:86638d96-703a-4264-b609-787004333d3f
Page Count                      : 44
Author                          : Ryan Stellmaker
Subject                         : 313516, Automatic AirPro Spray Guns
EXIF Metadata provided by EXIF.tools

Navigation menu