Instructions

Pro Xp Auto Control Module
User Interface for Pro Xp Auto Electrostatic Spray Guns.
For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual and the Graco
Automatic Electrostatic Gun manuals.
Save these instructions.

PROVEN QUALITY. LEADING TECHNOLOGY.

332989A
EN

Contents
Warnings ........................................................... 3
Models............................................................... 5

Setup Screen 5 ............................................ 20
Setup Screen 6 ............................................ 20

Overview............................................................ 5

Event Code Troubleshooting ............................... 21

Related Manuals ................................................ 5

Troubleshooting.................................................. 23

Installation..........................................................
Cable Connections.......................................
Fiber Optic Connections ...............................
Remote Mode I/O Connection.......................
Power Cord Connection ...............................
Grounding ...................................................

Diagnostic Information ........................................ 23

6
6
7
8
8
9

Operation ........................................................... 10
Module Screens........................................... 10
Preset ......................................................... 10
Module Keys................................................ 10
Icons ........................................................... 12
Screen Navigation and Editing ...................... 13
Screen Map ................................................. 14
Run Screens ...................................................... 16
Run Screen 1 .............................................. 16
Run Screens 2–5 ......................................... 17
Password Screen......................................... 17
Setup Screens.................................................... 18
Setup Screens 1 and 2 ................................. 18
Setup Screens 3 and 4 ................................. 19

2

Maintenance ...................................................... 24
Update Software .......................................... 24
Replace Battery ........................................... 24
Repair................................................................ 25
Fiber Optic Cable Repair .............................. 25
Fiber Optic Bulkhead Installation ................... 26
Parts.................................................................. 27
Accessories........................................................ 28
Fiber Optic Cables for Gun ........................... 28
Fiber Optic Cable Repair and
Accessories.................................... 28
Control Module I/O Cable Accessory
Kits ................................................ 28
Mounting Dimensions ......................................... 29
Technical Data ................................................... 29
Graco Standard Warranty.................................... 30

332989A

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.

WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help
prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and
plastic drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable
fumes are present.
• Ground all equipment in the work area. See Grounding instructions.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless
they are antistatic or conductive.
• Stop operation immediately if static sparking occurs or you feel a shock, Do not use
equipment until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
Static charge may build up on plastic parts during cleaning and could discharge and ignite
flammable vapors. To help prevent fire and explosion:
• Clean plastic parts only in well ventilated area.
• Do not clean with a dry cloth.
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can
cause electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before
servicing or installing equipment.
• Connect only to grounded power source.
• Use only 3–wire extension cords.
• Ensure ground prongs are intact on power and extension cords.
• All electrical wiring must be done by a qualified electrician and comply with all local codes
and regulations.
• Do not expose to rain. Store indoors.

332989A

3

Warnings

WARNING
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury,
including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes
but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent
manufacturer.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated
system component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data
in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete
information about your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment. Alterations or modifications may void agency approvals
and create safety hazards.
• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

4

332989A

Models

Models
Model Number

Series Description

24W035

A

Pro Xp Auto Control Module with software, mounting bracket and power supply
included. Fiber optic cables must be purchased separately.

24X216

A

Pro Xp Auto Control Module. Module Only.

Overview
The Pro Xp Auto Control Module is for use only with Pro Xp Auto Electrostatic Gun smart models. The control
module provides a user interface for up to two guns. Remote I/O allows communication with a Programmable
Logic Controller (PLC). The display control module performs the following functions:
• Display the spraying voltage and current.
• Change the gun voltage setting.
• Display the gun turbine speed.
• Store spray presets.
• Communicate equipment faults to a PLC.
• Display and set maintenance totalizers.
• Use a PLC to select a spray profile.

Related Manuals
Manual

Description

333010

Pro Xp Auto Air Spray Gun

333011

Pro Xp Auto AA Spray Gun

333012

Pro Xp Auto Waterborne Air Spray Gun

333013

Pro Xp Auto Waterborne AA Spray Gun

332989A

5

Installation

Installation
Cable Connections
Ports 1 through 4 of the Pro Xp Auto Control Module
are used in an automatic electrostatic gun installation.

Port

Description

1

Fiber Optic 1 (Gun 1)

2

Fiber Optic 2 (Gun 1)

3

Power Cord

4

Remote Mode I/O

5

Fiber Optic 1 (Gun 2)

6

Fiber Optic 2 (Gun 2)

Figure 1 Pro Xp Auto Control Module

6

332989A

Installation

Fiber Optic Connections
(Operational on Smart models only)
NOTE: Only use Graco supplied fiber optic cable. See
Fiber Optic Cables For Gun, page 28
The fiber optic cable connects the fiber optic ports
on the gun manifold to Ports 1 and 2 on the Control
Module.
For a 1 Gun System
1. Connect Port 1 of the gun 1 manifold to Port 1 of
the Control Module.
2. Connect Port 2 of the gun 1 manifold to Port 2 of
the Control Module.
For a 2 Gun System
1. Connect Port 1 of the gun 2 manifold to Port 5 of
the Control Module.
2. Connect Port 2 of the gun 2 manifold to Port 6 of
the Control Module.
Non-Hazardous Area

Hazardous Area
1
2
5
6

Port 1
Port 2
Port 5
Port 6

H Pro Xp Auto Smart
Gun
P 24 Volt Power Supply
Connection
Q Remote I/O
Connection
R Pro Xp Auto Control
Module
U Bulkhead (optional)
V Fiber Optic Cable
G1 Gun 1
G2 Gun 2

332989A

7

Installation

Remote Mode I/O Connection
The use of the Remote Mode I/O capability is
optional. Connector 4 on the Control Module is the
remote mode I/O port.

When remote mode is enabled, a Preset can be
selected by applying the following signals to Preset
Select 1 (pin 2) and Preset Select 2 (pin 4) of
connector 4.
Preset
Select 2
State

Preset
Select 1
State

Encoding

Selected
Preset

GND

GND

00

1

GND

+24 VDC
or Floating

01

2

+24 VDC
or Floating

GND

10

3

+24 VDC
or Floating

+24 VDC
or Floating

11

4

Figure 2 Connector 4 (I/O) Pinouts
Remote mode I/O cables are
available separately. See
Control Module I/O Cable Accessory Kits, page 28

During normal operation, Low kV Alarm Out (pin 3)
is at 0 V. When a low voltage alarm occurs, Low
kV Alarm Out (pin 3) is at 24 VDC. This occurs
regardless of remote mode setting.
NOTE: Low kV Alarm Out (pin 3) will read ~18 V
when inactive in an unloaded measurement.

Figure 3 Cable Pin Information
Pin No.

Wire Color

Function

1

Brown

+24 VDC

2

White

Preset Select 1

3

Blue

Low kV Alarm Out

4

Black

Preset Select 2

5

Gray

GND

8

Power Cord Connection
1. Connect the adapter cord (supplied) to Port 3 on
the control module.
2. Connect the 3–wire power cord (supplied) to the
adapter.
3. Plug the 3–wire power cord into a grounded
electrical outlet.

332989A

Installation

Grounding

The equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current.
The Pro Xp Auto Control Module is grounded by
an adapter and a 3–wire power cord (supplied)
connected to a grounded electrical outlet. If the
module is mounted to a bracket, connect a separate
ground wire to the bracket using a screw. Connect
the other end to a true earth ground.

332989A

A

Pro Xp Auto Control Module

B

Power Supply

C

Fiber Optic Cable

D

Pro Xp Auto Electrostatic Gun

E

Hazardous Area

F

Non-Hazardous Area

9

Operation

Operation
Module Screens

Module Keys

The Pro Xp Auto Control Module has two sets of
screens: Run and Setup. For detailed information see
Run Screens, page 16, and Setup Screens, page 18.

The control module display and keys are displayed
below. Table 1 explains the function of the membrane
keys on the control module. As you move through
the screens, you will notice that most information
is communicated using icons rather than words
to simplify global communication. The detailed
screen descriptions in Run Screens, page 16, and
Setup Screens, page 18, explain what each icon
represents. The two softkeys are membrane buttons
whose function correlates with the screen content to
the immediate left of the button.

Press
to toggle between the Run screens and
the Setup screens.

Preset
The presets can be used to store gun parameters.
Four presets are available for each gun. See
Setup Screens 1 and 2, page 18 to view and change
preset parameters.

NOTICE
To prevent damage to the softkey buttons, do not
press the buttons with sharp objects such as pens,
plastic cards, or fingernails.

Figure 4 Control Module Keypad and Display

10

332989A

Operation
Table 1 Module Keys

Membrane Keys

Softkeys
Enter Screen. Highlight data that can be edited.

Press to toggle between Run screens
and Setup screens.

Error Reset: Use to clear event after cause

Also changes the function of the Up/Down
arrows so they move between data fields on
the screen, rather than between screens.

has been fixed. Also used to cancel data
entered and return to original data.

Exit Screen. Exit data editing.

Up/Down Arrows: Use to move between
screens or fields on a screen, or to increment
or decrement the digits in a settable field.

Enter. Press to activate a field for editing or to accept

Softkeys: Use varies by screen.

Right. Move to the right when editing number fields. Press

See columns at right.

again to accept the entry when all digits are correct.

332989A

the highlighted selection on a dropdown menu.

11

Operation

Icons
As you move through the screens, you will notice that most information is communicated using icons rather
than words to simplify global communication. The detailed screen descriptions in Run Screens, page 16, and
Setup Screens, page 18, explain what each icon represents.

Screen Icons
Alarm

Preset Number

Deviation

kiloVolts/Voltage

Advisory

microAmperes/Current
Hertz/Frequency

Display ID

Electrostatic Gun

Screen Icons
Preset 3 Active

Preset 4 Active

Low kV Alarm Setpoint

Maximum kV Setpoint

Target Days

Remaining Days

Tip/Nozzle

Aircap

Turbine

Check Mark/Optional

Electrostatic Gun Active
Calendar

Gun 1

Units

Gun 2

Clock

Maintenance

Number of Guns
Password
Remote Mode
Preset 1 Active

12

Remote Mode Enabled

Preset 2 Active

332989A

Operation

Screen Navigation and Editing
Refer to this section if you have questions about
screen navigation or about how to enter information
and make selections.
All Screens
to move between screens.

1. Use

2. Press
to enter a screen. The first data field
on the screen will highlight.

Number Field
1. The first digit will be highlighted. Use
to change the number.
2. Press

3. When all digits are correct, press
accept.
4. Press

3. Use
change.
4.

Press

to highlight the data you wish to
to edit.

Drop Down Field
to highlight the correct choice from
1. Use
the dropdown menu.
2.

Press

3. Press

332989A

to move to the next digit.
again to

to cancel.

Check Box Field
A check box field is used to enable or disable features
in the software.
1. Press
box.

to toggle between

2. The feature is enabled if a

and an empty
is in the box.

to select.
to cancel.

13

Operation

Screen Map
Run Screens

Setup Screens

Run Screen 1, page 16

Setup Screen 1, page 18

2–5,, page 17
Run Screens 2–5

Setup Screen 2, page 18

(2 gun systems only)

2–5,, page 17
Run Screens 2–5

Setup Screen 3, page 19

2–5,, page 17
Run Screens 2–5

Setup Screen 4, page 19

(2 gun systems only)

2–5,, page 17
Run Screens 2–5

14

Setup Screen 5, page 20

332989A

Operation

Run Screens

Setup Screens
Setup Screen 6, page 20

332989A

15

Run Screens

Run Screens
When in Run Mode, the display shows the gun
parameters and the most recent 20 events. The
active gun preset can also be changed.

Run Screen 1
Use this screen to view the gun spraying voltage
in kilovolts (kV), the spraying current in microamps
(µA), and turbine frequency in hertz (Hz). The active
maximum spraying voltage is shown under the gun
icon. The active gun preset is operator settable to
presets 1-4. The maximum voltage setting for the
presets can be changed on setup screen 1. If the
device is in remote mode, the remote mode icon
shows up next to the preset select control. When
the gun has turbine power, the numbers will show
non-zero. When in two gun mode, the information
for both guns is shown.

Figure 7 Run Screen 1 in Manual Mode (2 gun
system)

Figure 8 Run Screen 1 in Remote Mode (2 gun
system)

NOTE: Only one preset is selected. Make sure your
presets are properly set up for both guns.
Run Screen 1 Key
Enter the screen to edit (manual mode
only).
Voltage Preset; operator selectable.
Changes the maximum spraying voltage
of the gun. Presets 1–4.
Figure 5 Run Screen 1 in Manual Mode (1 gun
system)

Electrostatic Gun. The number beneath
the icon is the active maximum spraying
voltage.
Also displays spraying voltage (kV) and
spraying current (µA).
NOTE: The number shown inside the
gun is the gun number.
Electrostatic Gun Active

Figure 6 Run Screen 1 in Remote Mode (1 gun
system)

16

Exit the screen (manual mode only).

332989A

Run Screens

Run Screens 2–5

Password Screen

Use Run Screens 2-5 to view the log of recent events.
The latest 20 events are viewable, with date and time.

If a password has been set, the Password Screen

NOTE: Run Screen 2 is shown as an example. Use
the arrow keys

to scroll through the screens.

is pressed from any Run screen.
displays when
Enter password to enable entry to the Setup screens.
Set the password to 0000 to disable password
protection. See Setup Screens 3 and 4, page 19 to
set or change the password.
NOTE: If you forget your password, use 1492 to gain
access and enter a new password.

Figure 9 Run Screen 2
Run Screen 2 Key
Date the event occurred.

Figure 10 Password Screen

Time the event occurred.
Indicates an event occurred.

Key
Press to activate a field for editing or
to accept the highlighted section on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.

332989A

17

Setup Screens

Setup Screens
The Setup Mode is used to set up a password
(if desired) and to set parameters for controlling
and monitoring the electrostatic gun. See
Screen Navigation and Editing, page 13 for
information on how to make selections and enter
data.

Setup Screens 1 and 2

Figure 11 Setup Screen 1

Use this screen to view and change preset
parameters. Presets can be used to store gun
parameters. Four presets are available for each gun.
• The first column shows the preset number (1-4).
• The second column shows the minimum voltage
setpoint for the preset, settable (in increments of 5)
between 0 and 50 kV for an 85 kV gun and between
0 and 40 for a 60 kV gun. If the spraying voltage
falls below the set value, the system will alarm.
Setting the control to zero disables the alarm.

Figure 12 Setup Screen 2 (2 gun system only)

Setup Screen 1 Key
Enter the screen.

• The third column shows the maximum voltage for
the preset, settable between 40 kV and 85 kV (in
increments of 5). Setting to anything other than
85 kV puts the gun into a low voltage mode. For
waterborne guns, voltage is settable between 30
kV and 60 kV.

Press to activate a field for editing or to
accept the highlighted selection on a
dropdown menu.

• NOTE: An 85kV gun’s normal high voltage reading
is 60–70 kV. If a ball end high voltage measurement
probe is used, the gun voltage will rise to about 85
kV. This will happen with all resistive electrostatic
guns.

Preset number.

• In two gun operation, a second screen is shown for
Gun #2 as indicated by the gun icon in the upper
left portion of the screen.

Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.

Set the maximum voltage setpoint for
the preset.
Set the minimum voltage for the low
voltage alarm for the preset.
Exit data editing.
Denotes which gun the settings belong to

18

332989A

Setup Screens

Setup Screens 3 and 4

Setup Screen 3 and 4 Key
Enter the screen.

Use this screen to view and reset the maintenance
totalizers. Maintenance totalizer units, shown on this
Setup Screen, are always in elapsed calendar days.
An Advisory is issued when the maintenance totalizer
reaches zero. To restart the timer, navigate to this
screen, edit the setpoint, and then clear the advisory
using the Error Reset button. As these timers are
based on the display date, the maintenance totalizers
must be reset if the date is changed. In two gun
operation, a second screen is shown for Gun #2 as
indicated by the gun icon in the upper left portion of
the screen.

Press to activate a field for editing or to
accept the highlighted selection on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Maintenance setpoint in calendar days.
Maintenance totalizer – Counts down
from setpoint to zero.
Aircap maintenance totalizer.
Tip/Nozzle maintenance totalizer.
Alternator maintenance totalizer.
Check/Optional maintenance totalizer

Figure 13 Setup Screen 3

Exit data editing.
Denotes which gun the settings belong to

Figure 14 Setup Screen 4 (2 gun system only)

332989A

19

Setup Screens

Setup Screen 5

Setup Screen 6

Use this screen to set date format, date, time, and
backlight timeout.

Use this screen to activate or change a password
that will be required to access the Setup screens
and to enable/disable remote voltage preset control.
This screen also displays the software version. This
screen is also used to select the number of guns for
the system (1 or 2).

Figure 15 Setup Screen 5
Setup Screen 5 Key
Enter the screen.
Figure 16 Setup Screen 6
Press to activate a field for editing or to
accept the highlighted selection on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Select your preferred date format from
the dropdown menu.
MM/DD/YY
DD/MM/YY
YY/MM/DD
Set the current date.

Setup Screen 6 Key
Enter the screen.
Press to activate a field for editing or to
accept the highlighted selection on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Enable/Disable the password with the
checkbox control. Enter the desired
password (if enabled).

Set the current time.

Enable/Disable remote voltage preset
control.

Set the display backlight timeout (in
minutes). A setting of zero means that
the backlight is on continuously.

Exit data editing.

Exit data editing.

Choos 1 for a 1 gun system, 2 for a 2
gun system.
Display ID setting. For advanced
installations only.

20

332989A

Event Code Troubleshooting

Event Code Troubleshooting
Event codes can take four forms:
• Alarm

: critical event; must be addressed immediately.

• Deviation
• Advisory

: critical event; requires attention.
: non-critical event; requires attention.

• Record: Useful information for troubleshooting.

To clear an event code, press
Icon

332989A

.

Code

Gun

Description

V1D1

Gun 1

V1D2

Gun 2

Low kV Alarm.
The low kV alarm displays when
the spraying voltage drops below
the user-set minimum.

CBD1

Gun 1

CBD2

Gun 2

CAI1

Gun 1

CAI2

Gun 2

MD11

Gun 1

MD21

Gun 2

MD12

Gun 1

MD22

Gun 2

MD13

Gun 1

MD23

Gun 2

MD14

Gun 1

MD24

Gun 2

How to Correct and Clear
Decrease conductivity of paint or
increase distance to part.
Press clear button to clear alarm.

Fiber Optic Communication Deviation. Check fiber optic cables and gun
The fiber optic communication alarm power.
displays when the display receives
Press clear button to clear alarm.
bad data from the gun.
Power Supply Communication Lost Deviation.
The gun fiber optic board loses communication with the gun power supply.

Check internal gun connections and
verify turbine air pressure.
Press clear button to clear alarm.

Turbine Maintenance Advisory.
The turbine maintenance totalizer
target value was reached.

Perform maintenance and reset
maintenance totalizer.

Tip/Nozzle Maintenance Advisory.
The tip/nozzle maintenance totalizer
target value was reached.

Perform maintenance and reset
maintenance totalizer.

Aircap Maintenance Advisory.
The aircap maintenance totalizer
target value was reached.

Perform maintenance and reset
maintenance totalizer.

Check/Optional Maintenance Advisory.
The check/optional maintenance
totalizer target value was reached.

Perform maintenance and reset
maintenance totalizer.

Press clear button to clear alarm.
Alarm will not clear until maintenance
totalizer has been reset.

Press clear button to clear alarm.
Alarm will not clear until maintenance
totalizer has been reset.

Press clear button to clear alarm.
Alarm will not clear until maintenance
totalizer has been reset.

Press clear button to clear alarm.
Alarm will not clear until maintenance
totalizer has been reset.

21

Event Code Troubleshooting

Icon

Code

Gun

Description

K2D1

Gun 1

K2D2

Gun 2

Turbine Frequency Low Advisory.
Turbine frequency below 400Hz at
85kV or below 325Hz at lower voltage.

K3D1

Gun 1

K3D2

Gun 2

WMC1

22

Turbine Frequency High Advisory.
Turbine frequency above 750Hz at
85kV or above 675Hz at lower voltage.
Invalid Hardware
The invalid hardware alarm displays
when the display control module
is not the correct version to work
with the Pro Xp Auto.

How to Correct and Clear
Increase turbine air pressure.
Press clear button to clear alarm.
Decrease turbine air pressure.
Press clear button to clear alarm.
Verify the proper display control
module part number is being used.
See parts page for valid part numbers.

EAD1

Preset 1 Activated Record.
This record shows when preset
1 was activated.

No action required. Shown on the
event log for information only.

EAD2

Preset 2 Activated Record.
This record shows when preset
2 was activated.

No action required. Shown on the
event log for information only.

EAD3

Preset 3 Activated Record.
This record shows when preset
3 was activated.

No action required. Shown on the
event log for information only.

EAD4

Preset 4 Activated Record.
This record shows when preset
4 was activated.

No action required. Shown on the
event log for information only.

332989A

Troubleshooting

Troubleshooting
Problem

Cause

Display is completely dark.

Solution

Power is not on.

Turn power supply on.

Loose or disconnected power
cable.

Tighten or connect cable.

Incorrect fiber optic cable
connections.

Check connections. See
Fiber Optic Connections, page 7 .

Bad fiber optic cable.

Check cable for damage. Replace
or repair fiber optic cable. See
Fiber Optic Cable Repair, page 25

Gun board error.

Turn off turbine air, then turn back
on to cycle power to gun board.

Clock stops functioning

Dead battery.

Replace battery. See
Replace Battery, page 24

Display has power but does not
function.

Hardware failure.

Replace display module.

Gun is on but no numbers are
showing.

Diagnostic Information
The LEDs on the bottom of the control module give important information about system function.

LED Signals
Signal

Description

Green On

Control module is powered up.

Yellow

Internal communication in progress.

Red solid

Control module failure. See Troubleshooting, page 23.

Red flashing

Software is updating.

Red flashing slowly

Token error; remove token and upload software token again.

332989A

23

Maintenance

Maintenance
Update Software
Manual 3A1244 will accompany any necessary
software updates. Follow all instructions in Manual
3A1244 to update your control module software.

Replace Battery
Replace the battery only if the clock stops functioning
after disconnecting power or a power failure.

Sparking can occur when changing the battery.
Replace the battery only in a non-hazardous
location, away from flammable fluids or fumes.

5. Use a flathead screwdriver to pry out the old
battery.

NOTICE
To avoid damaging the circuit board, wear a
grounding strap.
1. Disconnect power.
2. Remove the module from the bracket.
3. Attach grounding strap.
4. Remove 4 screws, and then remove the access
cover.

NOTE: Dispose of battery properly in an
approved container and according to applicable
local guidelines.
6. Replace with new battery. Ensure battery fits
under connector tabs before snapping other end
in place.

NOTE: Use only Panasonic CR2032 batteries for
replacement.
7. Reassemble access cover and screws.
8. Snap the module back into the bracket.

24

332989A

Repair

Repair
Fiber Optic Cable Repair
NOTE: Fiber optic repair kit 24W875 includes fittings
NOTE
for one double strand fiber optic cable and a cutter
tool. Cutter tool 24W823 may also be purchased
separately.
1. Make a clean cut to the ends of the cable using
fiber optic cutter tool (8). Ensure the ends of the
cable are equal length.
2. Add fiber optic fitting parts (2) to cable as shown.
Keep track of mounting ends using fiber optic
markers (4, 5).
3. For the end of the cable that connects to the Pro
Xp Auto Control Module or to a bulkhead, thread
on fiber optic nut (3) to length A equaling .31 in
(5/16”) (7.9 mm).
4. For the end of the cable that connects to the Pro
Xp Auto gun, the length must be adjusted for
your gun model. For rear manifold gun models
(model numbers LA1xxx or HA1xxx) adjust
length A to .31 in (7.9 mm). For bottom manifold
gun models (model numbers LA2xxx or HA2xxx)
adjust length A to 1.02 in (25.9 mm).

Fiber Optic Cable Connector Adjustment
FO Cable Description
Kit

Dimension A

24X003� Fiber Optic Cable, Rear
Manifold, 25 ft

0.31 in
(7.9 mm)

24X004� Fiber Optic Cable, Rear
Manifold, 50 ft

0.31 in
(7.9 mm)

24X005� Fiber Optic Cable, Rear
Manifold, 100 ft

0.31 in
(7.9 mm)

24X006� Fiber Optic Cable, Bottom 1.02 in
(25.9 mm)
Manifold, 25 ft
24X007� Fiber Optic Cable, Bottom 1.02 in
(25.9 mm)
Manifold, 50 ft
24X008� Fiber Optic Cable, Bottom 1.02 in
(25.9 mm)
Manifold, 100 ft
� Cutter tool 24W823 is included in these cable kits.

NOTICE
Fiber optic cable ends must be cut clean and
square to ensure proper function. Dimension A
must be adjusted for the gun model used to ensure
proper function.

When using a Graco provided cable, Dimension A
is set at the factory.

332989A

25

Repair

Fiber Optic Bulkhead Installation
Stainless Steel Bulkhead

Plastic Bulkhead

Accepts Graco fiber optic cable fittings. Fits 1/2 inch
(13 mm) panel hole.

Accepts bare fiber optic cable. Fits 5/15” (8 mm)
panel hole.

24W876 Stainless Steel Bulkhead Installation

24W877 Plastic Bulkhead Installation

1. Drill a 1/2 in. to 9/16 in (12.7 mm to 14.2 mm)
hole in booth wall or panel to allow bulkhead to
pass through.

1. Drill a 5/16 in. to 3/8 in (7.9 mm to 9.5 mm) hole
in booth wall or panel to allow bulkhead to pass
through.

2. Make sure fiber optic cables meet dimensions as
outlined in fiber optic repair instructions.

2. Make a clean cut to the ends of the cable using
fiber optic cutter tool (8). Ensure the ends of the
cable are equal length.

3. Insert bulkhead (6) into hole and attach nut
(7) on either side. Thread in fiber optic cable
fitting (2) until it bottoms out. Do not force cable
further. Make sure cable marker numbers match
to ensure proper communication.

3. Insert bulkhead (6) into hole and attach nut (7)
on either side. Insert cable into bulkhead and
tighten cinch nut down to a snug fit.
4. Repeat for second side of communications.

4. Repeat for second side of communications.

26

332989A

Parts

Parts
24W035 — Pro Xp Auto Control Module Kit

Figure 17

Ref.

Part

Description

Qty.

1

24X216

Pro Xp Auto Control Module

1

2

277853

Mounting Bracket

1

3�

16P265

Warning Label

1

5

24W880

Power Supply with Cord Set

1

5a

119253

Ferrite

1

6

244524

Ground Wire Assembly (not shown)

1

� Replacement Danger and Warning labels, tags, and cards are available at no cost.
NOTE: The power supply has a IEC 320–C13 male connector for a power cord. A North American power cord
with a NEMA 5–15P plug is included. A US power cable is provided with kits 24W035 and 34W880. Contact
your local sales person if a global power cable is required.

332989A

27

Accessories

Accessories
Fiber Optic Cables for Gun

Fiber Optic Cable Repair and
Accessories

Models With Rear Manifolds (Model numbers
LA1xxx or HA1xxx)

Kit Number

Description

Kit Number

Description

24W875

24X003

Fiber Optic Cable, Rear Manifold,
25 ft

24X004

Fiber Optic Cable, Rear Manifold,
50 ft

Fiber Optic Repair Kit —
Includes fittings for one
double-strand fiber optic
cable and a cutter tool.

24W876

Fiber Optic Bulkhead
Fitting, SST — Qty 2.
Accepts Graco fiber optic
cable fittings. Fits 1/2 inch
(13 mm) panel hole.

24W877

Fiber Optic Bulkhead,
Plastic — Qty. 2.
Accepts bare fiber optic
cable. Fits 5/16 inch (8mm)
panel hole

24X005

Fiber Optic Cable, Rear Manifold,
100 ft

Models With Bottom Manifolds (Model numbers
LA2xxx or HA2xxx)
Kit Number

Description

24X006

Fiber Optic Cable, Bottom Manifold,
25 ft

24X007

Fiber Optic Cable, Bottom Manifold,
50 ft

24W823

Fiber Optic Cutter Tool —
Qty. 3.

24X008

Fiber Optic Cable, Bottom Manifold,
100 ft

24X009

Marker Numbers for Fiber
Optic Cable Ends — Pack
of 30 (#1 and #2)

Control Module I/O Cable Accessory
Kits

28

Kit Number

Description

24W881

I/O cable, 50 ft

24W882

I/O cable, 100 ft

332989A

Mounting Dimensions

Mounting Dimensions

A
Overall Width
in. (mm)

B
Overall Height
in. (mm)

Overall
Depth
in. (mm)

Mounting Dimensions
Width (C) x Height (D)
in. (mm)

E
Mounting
Hole Size
in. (mm)

7.2 (183)

6.0 (152)

2.8 (71)

2.5 x 3.0 (64 x 76)

0.28 (7)

Technical Data
US

Metric

Operating Temperature

32° to 122°F

0° to 50°C

Storage Temperature

–22° to 140°F

–30° to 60°C

Control Module

1 lb

0.45 kg

Mounting Bracket

1 lb

0.45 kg

Weight

Power Connection
External Power Requirements
Humidity

Straight IEC 320–C13 male connector and a North American
NEMA 5–15P male plug are provided.
100–240 Vac, 50/60 Hz, 0.8 amps
0 to 95 percent, non-condensing

Display housing is solvent resistant.

332989A

29

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its
name to be free from defects in material and workmanship on the date of sale to the original purchaser for
use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a
period of twelve months from the date of sale, repair or replace any part of the equipment determined
by Graco to be defective. This warranty applies only when the equipment is installed, operated and
maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction,
damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper
maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall
Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment
with structures, accessories, equipment or materials not supplied by Graco, or the improper design,
manufacture, installation, operation or maintenance of structures, accessories, equipment or materials
not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an
authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco
will repair or replace free of charge any defective parts. The equipment will be returned to the original
purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material
or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of
parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.
The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages
for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall
be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH
ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY
GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.),
are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable
assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from
Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other
goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or
otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents,
notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or
indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du
présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés,
donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures
concernées.

Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
To place an order, contact your Graco Distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original Instructions. This manual contains English. MM 332989

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2014, Graco Inc. is registered to ISO 9001
www.graco.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Compression 0020level           : 6
Compression 0020type            : auto
Config 0020 File                : C:\Program Files\PTC\Arbortext Editor\lib\standard.pdfcf
EPS0020processor                : PStill version 1.84.36
Graphics 0020resolution         : 600
Graphics 0020resolution 0020threshold: 900
JPEG0020quality                 : 80
PTC0020 Arbortext 0020 Build    : R61M020-1141
Print 0020 Engine               : Arbortext FOSI Print Publisher
Stylesheet                      : \\MFS1\VOL3\Dept\PUBS\Style Sheets\6.X Style Sheets\Graco Style Sheet 6.X rev G en.style
Create Date                     : 2015:02:05 09:23:21-06:00
Creator Tool                    : PTC Arbortext Editor
Modify Date                     : 2015:02:25 14:51:56-06:00
Metadata Date                   : 2015:02:25 14:51:56-06:00
Keywords                        : "MM 332989, 332989, 332989A, 332989EN, 33298EN-A, Pro Xp Auto Control Module, ..24W035; 24X216, Pro Xp Auto, Electrostatic, Spray Guns
Producer                        : PDFlib+PDI 9.0.2p2 (Win32)
Format                          : application/pdf
Description                     : Pro Xp Auto Control Module
Title                           : 332989A, Pro Xp Auto Control Module, Instructions, English
Creator                         : .
Subject                         : MM 332989, 332989, 332989A, 332989EN, 33298EN-A, Pro Xp Auto Control Module, ..24W035; 24X216, Pro Xp Auto, Electrostatic, Spray Guns
Document ID                     : uuid:ee2bacf6-eb51-49e3-9293-3a0df083d67f
Instance ID                     : uuid:e74ea3d8-f8cf-44e7-943f-36dcf33cf418
Page Count                      : 30
Page Layout                     : SinglePage
Graphics Resolution             : 600
JPEG Quality                    : 80
Print Engine                    : Arbortext FOSI Print Publisher
Compression Type                : auto
EPS Processor                   : PStill version 1.84.36
Config File                     : C:\Program Files\PTC\Arbortext Editor\lib\standard.pdfcf
PTC Arbortext Build             : R61M020-1141
Compression Level               : 6
Graphics Resolution Threshold   : 900
EXIF Metadata provided by EXIF.tools

Navigation menu