Instructions

G3 Lubrication Pump
Food and Beverage
Kit

333488A
EN

Converts a G3 Pump for use in food and beverage applications. For professional use only.

Model: 24V837
Maximum Working Pressure: 5100 psi (35.1 MPA,
351.6 bar)

Important Safety Instructions

Read all warnings and instructions in this manual
and the G3 Pump manual. Save all instructions.

Parts Included in Kit
Ref

Description

1*
2
3

ELEMENT, pump
FITTING, zerk
PLUG

Warnings
The following warnings are for the setup, use, grounding,
maintenance, and repair of this equipment. The exclamation
point symbol alerts you to a general warning and the hazard
symbols refer to procedure-specific risks. When these symbols
appear in the body of this manual or on warning labels, refer
back to these Warnings. Product-specific hazard symbols and
warnings not covered in this section may appear throughout
the body of this manual where applicable.

WARNING

Qty
1
1
2

SKIN INJECTION HAZARD

1a

High-pressure fluid from dispense device, hose
leaks, or ruptured components will pierce skin. This
may look like just a cut, but it is a serious injury that
can result in amputation. Get immediate surgical
treatment.
Follow Pressure Relief Procedure in this manual
when you stop dispensing and before cleaning,
checking, or servicing equipment.

3

1
2

3

*Note the grooves (1a) around the surface of the hex head of
the pump element (1) included in the kit. These grooves are
added to help the user differentiate between the original pump
element and the new pump element for use with food and beverage applications.

Instructions

Disassembly

Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever you
see this symbol.

The following instructions are for removing the pump element
currently installed in the G3 Pump. Reference numbers used
in these instructions correspond to parts included in the kit and
are provided on page 1. Parts identified with an alpha character are user provided or already installed components.

b
1

a
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid and
moving parts, follow the Pressure Relief Procedure when
you stop dispensing and before cleaning, checking, or
servicing the equipment.
To relieve pressure in the system, use two wrenches working
in opposite directions on pump outlet fitting to slowly loosen
fitting only until fitting is loose and no more lubricant or air is
leaking from fitting as shown in FIG. 1.
NOTE: When loosening pump element fitting do NOT loosen
pump element. Loosening pump element will change the output volume.

3
2

3

FIG. 2
1.

Disconnect power source.

2.

Relieve pressure following Pressure Relief Procedure
provided.

3.

Disconnect anything installed to pump element such as
pressure relief valves, output union or other fittings.

4.

Use a wrench to loosen pump element (1) and completely
remove pump element (FIG. 2).
NOTE: Make sure spring (a) retainer (b) and piston (not
shown) are removed with pump element.

5.

Remove zerk fitting (2) and plugs (3) as shown in FIG. 2.

Installation
1.

Examine new pump element (1). Make sure spring (a),
retainer (b) and piston are installed (FIG. 2).

FIG. 1

2.

Technical Data

Slide pump element into housing. Be careful not to cross
thread the pump element during installation.

3.

Hand tighten pump and then torque to 50 in.-lbs (5.6 N•m)
(FIG. 1).

4.

Apply thread sealant to stainless steel zerk fitting (2) and
install zerk fitting as shown in FIG. 2. Torque to 50 in.-lbs
(5.6 N•m).

5.

Apply thread sealant to stainless steel plugs (3) and install
plugs as shown in Fig. 2. Torque to 50 in.-lbs (5.6 N•m).

US
Maximum Working 5100 psi
Pressure
Wetted Parts

Metric
35.1 MPa, 351.6 bar

nylon 6/6 (PA), zinc plated steel, alloy
steel, stainless steel, nitrile rubber
(buna-N), PTFE

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 333488

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
May 2014



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-701
Create Date                     : 2009:12:15 10:08:57Z
Modify Date                     : 2014:05:30 14:34:06-05:00
Creator Tool                    : FrameMaker 11.0
Metadata Date                   : 2014:05:30 14:34:06-05:00
Job Ref                         : L095X
Web Statement                   : 333488 G3 Lubrication Pump Food and Beverage Kit
Producer                        : Acrobat Distiller 10.1.10 (Windows)
Keywords                        : "MM333488, 333488, 333488A, 333488EN, 333488EN-A, G3, lubrication pump, food,  beverage, English, 24V837 "
Copyright                       : May  2014
Marked                          : True
Format                          : application/pdf
Description                     : 333488 Installation instructions for replacing the pump element, zerk fitting and plugs on a G3 pump for use in food and beverage applications.
Title                           : 333488A G3 Lubrication Pump Food and Beverage Kit, Instructions, English
Creator                         : Terri Howard
Subject                         : MM333488, 333488, 333488A, 333488EN, 333488EN-A, G3, lubrication pump, food,  beverage, English, 24V837
Document ID                     : uuid:262383e3-1dad-48a6-a85d-2300c5282e9c
Instance ID                     : uuid:aed9eb06-6972-4f35-b48b-64be8467f785
Page Count                      : 2
Language                        : en
Author                          : Terri Howard
EXIF Metadata provided by EXIF.tools

Navigation menu