Instructions LD Series Oil and Grease Pump 3A1334E EN For dispensing non-corrosive and non-abrasive lubricants, oil, grease, and automatic transmission fluids in stationary or mobile installations. Use with compressed air only. For professional use only. Not for use with windshield washer fluid. List of models, including Maximum Fluid Pressure: • Oil Pump Models: page 2 • Grease Pump Models: page 3 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Related Translated Manuals Manual Number 3A1339 3A1345 3A1350 3A1360 3A1365 3A1370 3A1375 Language Spanish French German Russian Chinese Japanese Korean European Community Design Patent: 001278006-001; 001278006-002 Patents Pending Oil Pump Models Oil Pump Models All oil models include a 2” npt(m) bung adapter. PN Description Max air pressure Max Fluid Pressure 3:1 PUMPS psi Mpa bar psi Mpa bar 24G576 Universal 150 1.03 10.3 750 5.17 51.7 24G577 Universal 150 1.03 10.3 750 5.17 51.7 24G578 Universal 150 1.03 10.3 750 5.17 51.7 24G579* Multilength 150 1.03 10.3 750 5.17 51.7 24G580* Multilength 150 1.03 10.3 750 5.17 51.7 24G581* Multilength 150 1.03 10.3 750 5.17 51.7 24G582* 200L (55gal) drum 150 1.03 10.3 750 5.17 51.7 24G583* 200L (55gal) drum 150 1.03 10.3 750 5.17 51.7 24G584* 200L (55gal) drum 150 1.03 10.3 750 5.17 51.7 24G585* 1040 liter (275gal) tote 150 1.03 10.3 750 5.17 51.7 24G586* 1040 liter (275gal) tote 150 1.03 10.3 750 5.17 51.7 24G587* 1040 liter (275gal) tote 150 1.03 10.3 750 5.17 51.7 5:1 PUMPS psi Mpa bar psi Mpa bar 24G588 Universal 150 1.03 10.3 750 5.17 51.7 24G589 Universal 150 1.03 10.3 750 5.17 51.7 24G590 Universal 150 1.03 10.3 750 5.17 51.7 24G591* 5:1 Multilength 150 1.03 10.3 750 5.17 51.7 24G592* 5:1 Multilength 150 1.03 10.3 750 5.17 51.7 24G593* 5:1 Multilength 150 1.03 10.3 750 5.17 51.7 24G594* 200L (55gal) drum 150 1.03 10.3 750 5.17 51.7 24G595* 200L (55gal) drum 150 1.03 10.3 750 5.17 51.7 24G596* 200L (55gal) drum 150 1.03 10.3 750 5.17 51.7 24G597* 1040 liter (275gal) tote 150 1.03 10.3 750 5.17 51.7 24G598* 1040 liter (275gal) tote 150 1.03 10.3 750 5.17 51.7 24G599* 1040 liter (275gal) tote 150 1.03 10.3 750 5.17 51.7 Air inlet 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT Air inlet 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT 1/4"-18 NPT 1/4"-19 BSPP 1/4"-19 BSPT Fluid Inlet 1"-11.5 NPT 1-11 BSPP 1-11 BSPT 1"-11.5 NPT 1-11 BSPP 1-11 BSPT 1"-11.5 NPT 1-11 BSPP 1-11 BSPT 1"-11.5 NPT 1-11 BSPP 1-11 BSPT Fluid Inlet 1"-11.5 NPT 1-11 BSPP 1-11 BSPT 1"-11.5 NPT 1-11 BSPP 1-11 BSPT 1"-11.5 NPT 1-11 BSPP 1-11 BSPT 1"-11.5 NPT 1-11 BSPP 1-11 BSPT Fluid Outlet 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT Fluid Outlet 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT 1/2"-14 NPT 1/2"-14 BSPP 1/2”-14 BSPT * Includes universal pump and down tube, packaged separately. 2 3A1334E Grease Pump Models Grease Pump Models PN Description 50:1 PUMPS Max air pressure Max Fluid Pressure psi Mpa bar psi Mpa bar Air inlet Fluid Inlet Fluid Outlet 24G600 16kg (35lb) 150 1.03 10.3 7500 51.7 517 1/4"-18 Npt Priming piston 1/4"-18 Npt 24G601 16kg (35lb) 150 1.03 10.3 7500 51.7 517 1/4"-19 BSPP Priming piston 1/4"-19 BSPP 24G602 16kg (35lb) 150 1.03 10.3 7500 51.7 517 1/4"-19 BSPT Priming piston 1/4"-19 BSPT 24G603 55kg (120lb) 150 1.03 10.3 7500 51.7 517 1/4"-18 Npt Priming piston 1/4"-18 Npt 24G604 55kg (120lb) 150 1.03 10.3 7500 51.7 517 1/4"-19 BSPP Priming piston 1/4"-19 BSPP 24G605 55kg (120lb) 150 1.03 10.3 7500 51.7 517 1/4"-19 BSPT Priming piston 1/4"-19 BSPT 24G606 180kg (400lb) 150 1.03 10.3 7500 51.7 517 1/4"-18 Npt Priming piston 1/4"-18 Npt 24G607 180kg (400lb) 150 1.03 10.3 7500 51.7 517 1/4"-19 BSPP Priming piston 1/4"-19 BSPP 24G608 180kg (400lb) 150 1.03 10.3 7500 51.7 517 1/4"-19 BSPT Priming piston 1/4"-19 BSPT 3A1334E 3 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable. WARNING SKIN INJECTION HAZARD High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point dispense valve at anyone or at any part of the body. • Do not put your hand over the end of the dispense nozzle. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses and couplings daily. Replace worn or damaged parts immediately. FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources, such as cigarettes and portable electric lamps. • Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline. • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present. • Ground all equipment in the work area. • Use only grounded hoses. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. 4 3A1334E Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage. • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents. • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to: • Protective eyewear, and hearing protection. • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer. 3A1334E 5 Installation Installation NOTE: Reference letters and numbers in parentheses in the text refer to callouts in the figures and drawings. Grounding To reduce the risk of static sparking, ground the pump and all other components used or located in the dispensing area. Check your local electrical code for detailed instructions for your area and type of equipment. • Air and fluid hoses: Use only electrically conductive hoses. • Air compressor: Follow manufacturer’s recommendations. • Dispensing valve: Ground through connection to a properly grounded fluid hose and pump. • Object being dispensed to: Follow your local code. • Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity. • To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the dispensing valve firmly to the side of a grounded metal pail, then trigger the dispense valve. Ground all equipment: • Pump: Use a ground wire and clamp as shown in FIG. 1. a. Remove the ground screw (Z) and insert through the eye of the ring terminal at end of ground wire (Y). b. Fasten the ground screw back onto the pump and tighten securely. NOTE: To order a ground wire and clamp, order Graco Part No. 222011. Y Z ti16123 FIG. 1 6 3A1334E Installation Typical Installation The typical installation shown in FIG. 2 is only an installation guide. It is not an actual system design. Contact your Graco Distributor for assistance in designing a system to suit your needs. Stationary Mountings Recommended air line configuration to reduce moisture in pump C B E F M F A J G K D H N L ti16120 FIG. 2 Key (FIG. 2) A B C D E F G H J K L M N Fluid outlet line (flexible connection required) Pump Ground wire Pump runaway valve Air lubricator Bleed-type master air valve (required) • NPT - Part No. 110223 • BSP - Part No. 125272 Air regulator (self-relieving regulator required) • NPT - Part No. 24H420 • BSP - Part No. 24H419 Air filter Main air line Bung adapter - Part No. 24F918 Fluid inlet line (flexible connection required) Air inlet line (flexible connection required) Wall mount bracket - Part No. 24F910 3A1334E 7 Installation Installation Guidelines Pump Mounting Reference letters found in the following instructions, refer to Typical Installation diagram provided on page 7. 1. Install bung adapter (K) into bung mount/bracket/or drum cover. • A ball valve must be installed upstream of the regulator (G). 2. Install pump (B) into bung adapter (K). • The fluid outlet line (A), fluid inlet line (L) and air inlet line (M) must be flexible (such as a hose). B NOTE: To prevent damage to the pump, remove sediment from the bottom of the container before installing a pump on an existing container. A K aa The maximum working pressure of each pump in your system may not be the same. To reduce the risk of over-pressurizing any part of your system, which may result in component rupture, fire or explosion and cause serious bodily injury, be sure you know the maximum working pressure rating of each pump and its connected components. • Never exceed the maximum working pressure of the lowest rated component connected to a particular pump. • Be sure you know the maximum working pressure of each component. • Do not exceed the maximum pump cycle rate. • Regulate air pressure to prevent over pressurization at fluid section of the pump. • FIG. 3 Installing Outlet Hose (FIG. 3) 1. Connect the swivel adapter (aa) to the pump fluid outlet. Tighten securely and torque as recommended below: • • For NPT models: 1 to 1-1/2 turns past hand tight. For BSPT models: 1-1/2 to 2 turns past hand tight. 2. Connect the fluid hose (A) to the swivel adapter (aa). 3. Connect a suitable dispensing valve or extra hose to the 6-ft hose. Regulate air pressure to the pump so that no fluid line component or accessory is over pressurized. Stationary Mounting Layout Plan the layout for easy operator access to the pump air controls, sufficient room to change drums and a secure platform. 8 3A1334E Installation Air Line and Accessories NOTE: Install the air line accessories in the order shown in the Typical Installation on page 7. NOTICE Do not hang the air accessories directly on the air inlet. Mount them on brackets. Always use a flexible hose between all connections. The air inlet is not strong enough to support accessories and may cause one or more to break. • Use thread sealant on all male threads except swivel connections. • Install a pump runaway valve (D) to shut off the air to the pump if the pump accelerates beyond the pre-adjusted setting. A pump that runs too fast can be seriously damaged. • Install the air regulator (G) to control pump speed and pressure. For NPT models order Graco Part No. 24H420 or for BSP models order Graco Part No. 24H419. • Install a bleed-type master air valve (F) upstream from the pump air regulator (G) but within easy reach of the pump. For NPT models order Graco Part No. 110223 or for BSP models order Graco Part No. 125272. • On the main air supply line from the compressor, install an air line filter (H) to remove harmful dirt and contaminants from the compressor air supply. Follow Plate - Grease Models Only For grease models only a follow plate is required for pumping fluid from the drum. See page 12 for follow plate installation instructions. 3A1334E 9 Operation Operation Thermal Induced Pressure Relief (Oil pumps only) a THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury. Oil pumps have a built-in, thermal induced, pressure relief as shown in FIG. 4. To ensure system pressure will automatically bleed excess thermal induced system pressure through the pump and back to the oil reservoir: • Always use a relieving air pressure regulator to allow the pump/motor to run backwards. The regulator bleeds excess air pressure. • There should not be any obstructions between air inlet of pump and regulator. • There should not be any obstructions between the downstream plumbing and pump outlet such as closed ball valves or check valves. • There should not be any obstructions between the pump inlet and fluid container such as closed ball valves or check valves. • Only use Graco designed suction tubes for in-drum or in-tank applications. • Only use Graco designed suction tubes with a built-in relief device for wall mount applications. • Always use an inlet screen to prevent debris from plugging relief passages from entering the pump. - Do not operate the pump with out an inlet screen. • 10 Periodically inspect the inlet screen for plugging. Graco recommends inspecting the inlet screen every time the container is changed out. b FIG. 4 a = Pump cylinder relief passage b = Inlet check relief passage Thermal Relief Theory of Operation The pump operation is similar to most double acting reciprocating pumps. The pump only comes to a complete stop on the up stroke. The pump will stroke through on the down stroke due to the inlet check relief passage. Excess pressure due to downstream thermal expansion causes the air motor/pump to run backwards (downward). Fluid pressure is relieved through the inlet check relief passage as the pump piston moves downward. Air pressure is simultaneously relieved through the air inlet passage. The pump piston moves downward exposing the pump cylinder relief passage at the bottom of the stroke. Additional excess pressure is then relieved through both the inlet check relief passage and the pump cylinder relief passage. Pressure is relieved at the pump through the pump inlet relief passage. The pump will not change over on the bottom of the stroke as a result of relieving excess pressure due to the positioning of the pump cylinder groove with respect to the air motor pilot valve. NOTE: • The air supply does not have to be turned off to enable thermal relief activation. • The Thermal Induced Pressure Relief design feature of the pump will cause the pump to dive on the downstroke when a dispensing valve is closed. 3A1334E Operation Install only one pump per delivery system. Do not use the pumps in a parallel pump installation. Start-up Loss of pump prime can occur if all the following events occur in sequence: Determining Output Pressure Using the Air Regulator 1. A thermal relief event occurs. To determine the fluid output pressure using the air regulator reading, multiply the ratio of the pump by the air pressure shown on the regulator. 2. The air supply valve is closed. 3. A dispense valve located at an elevation higher than the tank level, is open. To prevent loss of prime, ensure the air supply valve is turned on before attempting to dispense fluid. Pressure Relief Procedure The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, fluid from the valve, or splashing fluid, follow this procedure whenever you: • • • • are instructed to relieve pressure stop dispensing check, clean, or service any system equipment install or clean dispensing devices. For example a 3:1 ratio oil pump: 3:1 ratio x 100 psi air = 300 psi fluid outlet A 3:1 pump is capable of 5:1 on the downstroke and will develop 5:1 pressures under normal operation. A grease pump has a ratio of 50:1. However it is capable of reaching a stall pressure equal to 60 times the air input pressure. To calculate the fluid output pressure using the air regulator reading, multiply the regulator gauge by 60. For example: 140 psi air x 60 = 8400 psi fluid output 0.97 MPa air x 60 = 58.2 MPa 99.7 bar x 60 = 582 bar Regulate air to the pump so that no air line or fluid line component or accessory is over pressurized. Priming the pump 1. Close the pump’s bleed-type master air valve. 2. Close the pump air regulator and disconnect the air supply hose. 3. Open the dispensing valve and dispense fluid into a waste bucket/container until pressure is fully relieved. If you suspect that the dispensing valve is clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the dispensing valve coupler or hose end coupling to relieve pressure gradually, then loosen completely. 1. Close the air regulators and bleed-type master air valves to all but one pump. 2. Open the master air valve from the compressor. 3. For the pump that is connected, trigger the dispensing valve into a grounded metal waste container making firm, metal-to-metal contact between the container and the valve. 4. Slowly open the bleed-type master air valve and open the pump air regulator just until the pump is running. When the pump is primed and all air has been pushed out of the lines, release the trigger. 5. If you have more than one pump, repeat this process for each pump in your system. NOTE: When the pump is primed and has sufficient air supplied to it, it starts when the dispensing valve is open and shuts off when closed. 3A1334E 11 Operation Step 6 is for Oil Pumps Only: 6. The thermal relief feature of this oil pump can increase the amount of time needed to fully prime the pump when compared to pumps without a thermal relief feature. To minimize this effect, prime the pump before connecting it to an already primed distribution system. Changing Grease Drum and Installing Follow Plate (grease models only) 1. Relieve pressure, page 10. NOTICE Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system. 2. Remove drum cover by loosening thumb screws (a) (FIG. 5). a NOTE: A pump runaway valve can be installed on the air line to automatically shut off the pump if it starts to run too fast. FIG. 5 7. Read and follow the instructions supplied with each component in your system. 8. When shutting off the system and before checking or servicing, relieve pressure following pressure relief procedure, page 10. 3. Remove pump and cover from drum and place on a clean paper, cardboard, or clean shop rags. DO NOT PLACE ON SHOP FLOOR. 4. If this is an existing installation, reach into drum and pull on follow plate ring (b) to remove follow plate (FIG. 6). Place follow plate on a clean paper, cardboard or clean shop rags. DO NOT PLACE ON SHOP FLOOR. Remove drum and install new one. b FIG. 6 12 3A1334E Operation 5. Examine follow plate to make sure rubber grommet (c) is in place in center of the plate (FIG. 7). 7. Insert pump drop tube through center of rubber grommet in follow plate (FIG. 9). Se c FIG. 7 6. Set follow plate on top of fresh grease (FIG. 8). Remove air by pushing on the follow plate until the grease level is flush with the opening in the middle of the follow plate (d). FIG. 9 8. Tighten thumb screws (a) to secure cover to drum. d a FIG. 8 FIG. 10 9. For the pump that is connected, trigger the dispensing valve into a grounded metal waste container making firm, metal-to-metal contact between the container and the valve. 10. Slowly open the bleed-type master air valve and open the pump air regulator just until the pump is running. When the pump is primed and all air has been pushed out of the lines, release the trigger. 3A1334E 13 Repair Repair Replacing Pilot Valves Reference letters shown in the following instructions refer to Typical Installation diagram, page 7. Part numbers refer to the Parts pages beginning on page 15. 1. Stop pump at the middle of its stroke. 2. Relieve pressure, page 11. 3. Disconnect the air line (M). 4. Use a 10 mm socket wrench to remove the old pilot valve (20). 5. Lubricate o-rings and install the new pilot valve (20). Torque to 95-105 in-lb (11-12 N.m). 14 3A1334E Parts Parts 3:1 Oil Pump Models: 24G576 - 24G587: 5:1 Oil Pump Models: 24G588 - 24G599 Ref Part No Description 2 116343 Qty Ref Part No Description SCREW, ground 1 40 ▲ 16G243◆ LABEL, safety, warning, multiple 3 SCREW 3 4 SCREW M6 x 22 mm 5 43 50 ✿ 24F918 O-RING, air piston 1 51 16G121★ STRAINER O-RING 1 O-RING 1 O-RING, 1 SEAL, u-cup 1 PIN, spring 1 BALL, steel 1 BALL, steel 1 ✓ O-RING, (models 24G576 - 24G578) 1 O-RING (models 24G588 - 24G590) O-RING 1 1 16F951 14 ✓ ✓ 15 ✓★ O-RING 1 16F885 SCREW 1 ✠ O-RING 3 BOLT M8 X 25 1 5 6 7 8 9 ✠ ✠ ✠ ✠ ✠ 10 11 ★ 12 13 16 17 18 19 20 ◆✖ WASHER, M8 (not shown) 1 VALVE, pilot 2 16F878 16F948 52‡ 16F949 16F886 53‡ 16F950 54‡ 16F962 16F963 ✠ 55 SCREW, M6 x 25 mm ADAPTER, bung, LD pump TUBE, PVC, LD pump (models 24G579, 24G591) TUBE, PVC, LD pump (models 24G580, 24G592) TUBE, PVC, LD pump (models 24G581, 24G593) TUBE, metal, LD pump (models 24G582, 24G594) TUBE, metal, LD pump (models 24G583, 24G595) TUBE, metal, LD pump (models 24G584, 24G596) TUBE, metal, LD pump (models 24G585, 24G597) TUBE, metal, LD pump (models 243G586, 24G598) TUBE, metal, LD pump (models 24G587, 24G599) O-Ring (not shown) Qty 1 8 1 1 1 1 1 1 1 1 1 1 1 1 21 PISTON, air, plastic 1 22 BEARING, delrin 1 ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. ❖ †✿ ◆ SEAL, air valve, manifold (not shown) 1 ‡ Packaged separately with universal pump. 15M213 MUFFLER, 3/8 1 112933 MUFFLER, quiet (optional) 1 ✠ GASKET, cover, small 2 26 COVER, bottom, machining 1 27 CYLINDER air, machined 1 HOUSING, intake valve, machined 1 29 30 FLANGE, oil, machined ROD, displacement 1 1 ❖ † ✿ 31 GUIDE, air 1 ◆ 32 CYLINDER, fluid 1 33 34 PISTON, pump, 3:1, machining HOLDER, ball 1 1 23 24 25 28 35 15M182 ★ ★ SPRING, compression 1 36 SPRING, compression 1 37 HOUSING, manifold, machined 1 ✿ 39 ▲ 16F541 VALVE, air, small LABEL, identification, lD 3:1 1 1 38 3A1334E ✠ ✓ ★ ✖ Included in kit 24H853 Included in kits 24K293 - 3:1; 24H855 - 5:1 Included in kits 24H611 (npt), 24J430 (bspp) 24J431 (bspt) Included in kit 24H798 Included in kit 24H851 Included in kit 24H848 (npt), 24H849 (bspp), 24H850 (bspt) Included in kit 24J757 (npt), 24J758 (bspp), 24J759 (bspt) Included in kit 24H749 15 Parts Related Oil Pump Kits Throat and Piston Seal Replacement Kit 24H853 (FIG. 12) Kit No. NOTE: When servicing the throat and piston seals, it is recommended to also replace seals in the pump lower. Order repair kit: 24K293 for 3:1 pumps or 24H855 for 5:1 pumps. Instructions related to this kits are included in instruction manual 3A1494 (included with the kit). 24H611 24J430 24J431 Description Qty KIT, repair, intake valve, npt, includes 11, 15, 28, 35, 51 KIT, repair, intake valve, bspp, includes 11, 15, 28, 35, 51 KIT, repair, intake valve, bspt, includes 11, 15, 28, 35, 51 1 1 1 O-Ring Replacement Kit - 24K293 for 3:1 pumps; 24H855 for 5:1 pumps (FIG. 11) NOTE: When replacing seals in the pump lower also service the throat and piston seals. Order repair kit 24H853. Instructions related to this kit are included in instruction manual 3A1494 (included with the kit). Ref. 13 14 15 Description O-RING O-RING O-RING Ref. 5 6 7 8 9 17 25 55 Description O-RING, air piston O-RING O-RING O-RING, wiper SEAL, u-cup O-RING GASKET, cover, small O-RING (not shown) Qty. 1 1 1 Qty. 1 1 1 1 1 3 2 1 7 9 5 13 8 14 15 FIG. 11 25 17 6 FIG. 12 16 3A1334E Parts Kits Page 21 20 1 27 18 6 40 39 19 30 10 21 5 3 17 4 31 34 36 3 12 33 5 6 26 13 14 52, 53 or 54, Page 15 7 1 20 22 32 2 11 9 8 3 35 11 4 15 29 2 1 Torque to 95-105 in lbs (10.7 - 11.9 N•m) 2 Torque to 20 - 25 ft lbs (27- 34 N•m) 3 Torque to 60 - 70 in lbs (6.8 - 7.9 N•m) 4 Torque to 25 - 35 in lbs (2.8 - 3.9 N•m) 5 Torque to 110 - 120 in lbs (12.4 - 13.6 N•m) 6 Torque to 80 - 90 in lbs (9.0 - 10.2 N•m) 11 4 28 51 2 50 Lips face down 3A1334E 17 Parts 50:1 Grease Pump Models: 24G600 - 24G608 Ref Part No. Description 2 116343 SCREW, ground Qty Ref Part No. Description Qty 1 34 ROD, priming 1 3 SCREW 3 35 PISTON, shovel, 50:1 1 4 SCREW, M6 X 22 mm 5 36 CYLINDER, spacer 1 O-RING, air piston 1 37 NUT, retainer 1 O-RING (not shown) 1 38 WASHER, 30 OD 1 O-RING 10 39 HOUSING, manifold, machined 1 PIN, straight, slotted, 2.5x16 3 40 VALVE, air, small 1 SCREW 1 41 ▲ 1GH013 LABEL, identification, LD 50:1 1 O-RING 1 42 ▲ 16G243 LABEL, safety, warning, multiple 1 SEAL, u-cup 1 43 O-RING 3 13 WASHER,M8 1 14 COVER, bottom, machining 1 15 PISTON, air, plastic 1 SEAL, air valve, manifold 1 5 6 7 8 + + + +@ 9 10 11 12 16 @ + + 15M182 ❖ † ✿◆ + ✿◆ ✿ + @ ★ 1 112933 MUFFLER, quiet (optional) 1 + GASKET, cover, small 2 NUT, hex 2 VALVE, pilot 2 ◆ 21 CYLINDER, air, machined 1 22 FLANGE, bottom cover, grease, 1 ✖ 23 ROD, piston, 50:1 1 SEAL, piston 1 25 ROD, displacement, 50:1 1 26 CYLINDER, HP 50:1 1 18 19 20 24 ◆✖ @ 27 24J380 KIT, cylinder, shovel 1 28 @ SEAL, intake 1 RETAINER, seal, al 1 GASKET 2 31 BEARING, throat 1 32 ROD, connection 1 33 GUIDE, air 1 29 30 18 +@ 8 ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. 15M213 MUFFLER, 3/8 17 SCREW, M6 x 25 mm ❖ † ✿ Included in kit 24H854 Included in kits 24H856 Included in kits 24H611 (npt), 24J430 (bspp) 24J431 (bspt) Included in kit 24H798 Included in kit 24H851 Included in kit 24H848 (npt), 24H849 (bspp), 24H850 (bspt) Included in kit 24J757 (npt), 24J758 (bspp), 24J759 (bspt) Included in kit 24H749 3A1334E Parts Related Grease Pump Kits Throat and Piston Seal Replacement Kit 24H854 (FIG. 13) O-Ring and Seal Replacement Kit - 24H856 (FIG. 14) Instructions related to this kit are included in instruction manual 3A1495 (included with the kit). Instructions related to this kit are included in instruction manual 3A1495 (included with the kit). Ref. 5 6 7 8 11 12 18 30 37 Ref. 8 10 24 28 30 Description O-RING, air piston O-RING O-RING PIN, slotted, straight SEAL, u-cup O-RING GASKET, cover, small GASKET NUT, retainer 7 Qty. 1 1 1 3 1 3 2 1 1 Description PIN, slotted, straight O-RING SEAL, piston SEAL, intake GASKET Qty. 3 1 1 1 2 30 18 24 8 11 6 28 8 10 12 FIG. 14 30 37 5 FIG. 13 3A1334E 19 Parts 1 Torque to 95-105 in lbs (10.7 - 11.9 N•m) 3 Torque to 60 - 70 in lbs (6.8 - 7.9 N•m) 7 Torque to 70 - 80 in lbs (7.9 - 9.0 N•m) 8 Torque to 45 - 55 ft lbs (61 - 75 N•m) 9 Torque to 30 - 40 in lbs (3.4 - 4.5 N•m) 20 1 21 41 30 36 8 10 Torque to 30 - 35 in lbs (3.4 - 4.0 N•m) 11 Lips face down 30 42 13 Kits, page 21 7 26 8 19 5 15 8 38 10 37 24 11 11 23 31 1 10 29 8 3 25 12 3 9 28 8 6 33 34 20 14 7 35 19 7 22 3 4 27 8 9 20 2 32 3A1334E Parts Oil or Grease Pump Air Valve Repair and Replacement Kits Air Valve Seal Kit - 24H851 Ref. Instructions related to the following kits are included in instruction manual 3A1496 (included with the kit). Replace Seals or Rebuild Air Valve Kits Oil Grease 23 16 Description Qty. SEAL, air valve, manifold 1 381 381 O-RING, 018 buna 2 382 382 SEAL, u-cup, bevel lip 2 383 383 SCREW, M3, thread forming 2 Air Valve Repair Kit - 24H798, Air Valve Seal Kit 24H851 and Air Valve End Cap - 24H852. 382 1 Air Valve Repair Kit - 24H798 Ref. 381 Description Qty. 16 SEAL, air valve, manifold 1 381 381 O-RING, 018 buna 2 382 382 SEAL, u-cup, bevel lip 2 383 383 SCREW, M3, thread forming 2 386 386 PISTON, air valve 1 387 387 ROLLER, assembly, detent 1 388 388 PLATE, air valve 1 389 389 SPRING, detent, small 1 390 390 CUP, air valve, small 1 391 391 CAM, detent, small 1 Oil Grease 23 381 391 1 Lips face down 2 Lips face up 382 1 382 2 23/16 1 Lips face down 2 Lips face up 381 FIG. 16 Air Valve End Cap Kit - 24H852 Ref. Description Qty. 381 O-RING, 018 buna 2 384 PLUG, air valve 2 385 RING, snap 2 381 386 390 387 383 388 384 385 389 FIG. 17 2 382 381 FIG. 15 3A1334E 383 23/16 21 Parts Air Valve Replacement Kit - 24H848 (npt), 24H849 (bspp), 24H850 (bspt) (FIG. 18) Pilot Valve Replacement Kit - 24H749 This kit only includes the pilot valves (20). If you also are repairing/replacing the air valve (38/40) and air valve seal (23/16) order the Air Motor Service Kit 24J757 (npt), 24J758 (bspp) or 24J759 (bspt). 38/40 Ref. Description 20 VALVE, pilot 43 Qty. 2 Air Motor Service Kit - 24J757 (npt), 24J758 (bspp), 24J759 (bspt) (FIG. 19) 23/16 I FIG. 18 38/40 Ref. Description Qty. Oil Grease 23 16 SEAL, air valve 1 38 40 VALVE, air, small 1 43 43 SCREW, M6 x 25 4 20 23/16 FIG. 19 Ref. 22 Oil Grease 20 23 40 20 16 40 Description VALVE, pilot SEAL, air valve VALVE, air, small Qty. 2 1 1 3A1334E Troubleshooting Troubleshooting NOTE: Check all other possible problems and solutions before disassembling the pump. Before you troubleshoot problems using the table below, relieve the pressure and disconnect the pump fluid line. If the pump starts when the air is turned on again, the fluid line, dispensing valve, etc. clogged. Oil Models Problem Pump runs but no fluid output Cause Solution Pump is not fully primed Crack a fitting at the outlet of the pump to allow a slow leak to purge any air in the pump. Repeat start up procedure, page 11. Oil leakage Check connection and tighten. The piston valve is not seating properly or the piston o-ring is damaged Check and replace parts as needed. Exhausted fluid supply Refill and reprime. The pump inlet filter is blocked Clear the filter The suction tube (hose) has an air leak Check the connection and tighten as needed. Service pilot valve. Damaged pilot valve Lower air pressure to prevent reoccurrence. Replace air valve. Damaged main air valve Pump fails to operate or stops Erratic or accelerated operation 3A1334E Lower air pressure to prevent reoccur an ce. Inadequate air supply pressure or restricted air lines. Increase air supply; clear. Closed or clogged dispensing valve Open valve if closed. Clear clog if necessary. Clogged fluid lines, hose valves, etc. Clear clogs. Damaged air motor Service air motor. Exhausted fluid supply Refill and reprime. Replace valve gasket. Damaged valve gasket Lower air pressure to prevent reoccurrence. 23 Troubleshooting Problem Cause Solution Replace gasket. Intermittent air leakage coming from behind the air manifold. Pump continues to function normally. Gasket is leaking Lower air pressure to prevent reoccurrence. Clear obstruction. Thermal relief inlet check relief passage in inlet housing is plugged Replace inlet filter. Worn or damaged piston o-ring or valve cup. Continuous air exhaust Pump operates but output is low Oil leakage through air exhausts 24 Service air motor / valve Replace valve gasket. Damaged valve gasket Lower air pressure to prevent reoccurrence. Held open or worn intake valve Clear; service. Held open or worn pump piston packings Clear; service. The muffler is partially blocked Clear muffler. The inlet filter is partially blocked Clear the filter. Inadequate air supply pressure or restricted air lines Increase air supply; clear restrictions. Partially closed or clogged pilot valves Open valves. Clear clog as necessary. Partially clogged fluid line, hose, valves, etc. Clear clog as necessary. Throat seal is damaged Replace throat seal (u-cup). 3A1334E Troubleshooting Grease Models Pump fails to operate Inadequate air supply pressure or restricted air lines Increase air supply and/or clear restriction. Closed or clogged pump valves Open and/or clean. Clogged fluid line, hose, valve, or other accessory Relieve pressure. Clear obstruction. Damaged air motor Assess damage, and service air motor. Exhausted fluid supply Refill and reprime or flush. Continuous air exhaust Worn or damaged piston o-ring or valve cup Assess wear or damage, and service air motor. Erratic pump operation Exhausted fluid supply Refill and reprime or flush. Worn pump seals Replace. Damaged shovel tube Replace. Damaged check seat Replace pump piston or shovel rod (or other damaged part). Exhausted fluid supply Refill and reprime of flush. Fluid too heavy for pump priming Use inductor or follow plate. Errataic or accelerated pump speed Replace valve gasket. Pump operates but output is low Grease leaking from muffler 3A1334E Damaged valve gasket Lower air pressure to prevent reoccurrence. Worn piston seal Replace. Damaged upper check seat Replace pump piston. Worn fluid intake seal Replace. Damaged lower check seat Replace shovel rod. Inadequate air supply pressure or restricted air lines Increase air supply and/or clear restriction. Partially closed or clogged pump valves Open and/or clean. Air pockets in the grease inlet Eliminate the air pockets. Partially clogged fluid line, hose, valve, or other accessory Relieve pressure. Clear obstruction. Worn seals Replace. Worn throat seal Replace. 25 Technical Data Technical Data 3:1 or 5:1 Oil Models Maximum fluid working pressure 750 psi (51.7 bar, 5.17 MPa) Fluid pressure ratio 3:1 or 5:1 Suction lift (feet of oil) 10 Air operation range 20 to 150 psi (1.37 to 10.3 bar; 0.137 to 1.03 MPa) Recommended air pressure for optimum pump life <125 psi (8.6 bar, 0.86 MPa) Air consumption (at 100 psi) See Performance Curves, page 29 Cycles per gallon/(liter) 3:1 - 29 cycles per gallon (7 cycles per liter); 5:1 - 37 cycles per gallon) (10 cycles per liter) Maximum recommended pump speed 3:1 - 120 cycles per minute; 5:1 - 180 cycles per minutes Recommended speed for optimum pump life 75 cycles per minute and lower 3:1 - 2.6 gallons per minute (9.8 liters per minute); 5:1 - 2 gallons per minute (7.6 liters per minute) Wetted parts zinc plated carbon, steel, aluminum, nitrile, polyurethane, nickel plated aluminum Sound pressure level†* 72.9 dB(a) Sound power level‡* 82.0 dB(a) Performance curve See charts page 28 Approximate weight 3:1 - 7 pounds (3.2 kg); 5:1 - 7.7 pounds (3.5 kg) Dimensions See page 30 † Calculated at a distance of 1 meter from measurements taken per ISO 9614-2 @ 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minutes. ‡ Measured per ISO 9614-2 at 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minute. * Muffler 112933 can be ordered separately for reduced sound levels. 26 3A1334E Technical Data Dimensions Model L inches (mm) O (Overall Length) inches (mm) Universal Pump Only 6.9 (175) 16 (406) Multi* 42.4 (1076) 51.5 (1307) Drum 35.7 (907) 44.8 (1138) Tote 42.8 (1087) 51.9 (1318) *Multi down tube is angle cut to the desired length as required 3/8” (10 mm) minimum Multi/Drum/Tote Universal Pump a a O d d e e c c L b O a = 1/4 inch air inlet b = 1 inch fluid inlet c = 2 inch npt bung adapter d = ground screw e = 1/2 inch fluid outlet - opposite of d L b 3A1334E 27 Technical Data Performance Curve 3:1 Oil Models 3:1 Performance Curve Tested with ISO 46 Hyd Oil ,QOHW$LU3UHVVXUHV &\FOHVSHUPLQXWH 58 116 174 232 40 (1.1) 300 (20.7) 200 (13.8) $ $ 30 (.8) % % & 20 (.6) & 100 (6.9) 0 1 (3.8) 2 (7.6) SVL EDU % SVL EDU & SVL EDU 10 (.3) 5HFRPPHQGHG2SHUDWLQJ5DQJH 0 $LU)ORZVFIP PPLQ )OXLG3UHVXUHSVL EDU 400 (27.6) $ 3 4 5 (11.4) (15.1) (18.9) )OXLG)ORZJSP OSP 6 (22.7) 7 (26.5) 8 (30.3) 0 9 (34.1) 5:1 Oil Models 5:1 Performance Curve Tested with ISO 46 Hyd Oil ,QOHW$LU3UHVVXUHV &\FOHVSHUPLQXWH 74 148 400 (27.6) 300 (20.7) 200 (13.8) 40 (1.1) $ $ % % 28 SVL EDU & SVL EDU 20 (.6) & & 10 (.3) 5HFRPPHQGHG2SHUDWLQJ5DQJH 0 % 30 (.8) 100 (6.9) 0 SVL EDU $LU)ORZVFIP PPLQ )OXLG3UHVXUHSVL EDU 600 (41.4) 500 (34.5) $ 222 1 (3.84) 2 (7.6) 3 (11.4) 4 5 6 (15.1) (18.9) (26.5) )OXLG)ORZJSP OSP 0 7 (26.5) 3A1334E Technical Data 50:1 Grease Models Maximum working pressure 7500 psi (517 bar, 51.7 MPa) Fluid pressure ratio 50:1 Air operation range 20 to 150 psi (1.37 to 10.3 bar; 0.137 to 1.03 MPa) Air consumption (at 100 psi) See Performance Curve, page 30 Pump cycles per pound (cycles per kg) 47 cycle per pound (103 cycle per kg) Maximum recommended pump speed 120 cycles per minute Recommended speed for optimum pump life 60 cycles per minute or lower flow rate; 1.3 pounds per minute (0.6 kg per minute) Wetted parts steel, brass, nitrile rubber, polyurethane, UHMWPE, acetal Sound pressure level†* 72.9 dB(a) Sound power level‡* 82.0 dB(a) Performance curve See chart page 30 Approximate weight 35 pound drum - 11.2 pounds (5.1 kg); 120 pound drum - 15.0 pounds (6.8 kg); 400 pound drum - 170.0 pounds (7.7 kg) Dimensions See illustration below † Calculated at a distance of 1 meter from measurements taken per ISO 9614-2 @ 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minutes. ‡ Measured per ISO 9614-2 at 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minute. * Muffler 112933 can be ordered separately for reduced sound levels. Performance Curve Grease Models 50:1 Performance Curve Tested with ISO 46 Hyd Oil &\FOHVSHUPLQXWH 94 47 8000 (551.6) ,QOHW$LU3UHVVXUHV )OXLG3UHVXUHSVL EDU $ $ % % 3000 (206.8) 2000 (137.9) & & 3A1334E SVL EDU & SVL EDU 40 (1.1) 30 (.8) 20 (.6) 10 (.3) 1000 (68.9) 0 0.00 % $LU)ORZVFIP PPLQ 50 (1.4) 6000 (413.7) 4000 (275.8) SVL EDU 141 7000 (482.6) 5000 (344.7) $ 5HFRPPHQGHG2SHUDWLQJ5DQJH 0.50 (.23) 1.00 (.45) 1.50 (.68) 2.00 2.50 (.91) (1.13) )OXLG)ORZOEVP NJP 3.00 (1.36) 3.50 (1.59) 0 4.00 (1.81) 29 Technical Data Dimensions a = 1/4 inch air inlet b = 1/4 inch fluid outlet c = 2 inch npt mounting configuration d = ground screw a a a d d d c b c b c b 23.6 in. 600 mm 14.5 in. 370 mm 37.2 in. 945 mm 28.1 in. 715 mm 36.0 in. 915 mm 45.0 in. 1145 mm 35 pound drum 120 pound drum 400 pound drum 30 3A1334E Notes Notes 3A1334E 31 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 3A1334 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2011, Graco Inc. is registered to ISO 9001 www.graco.com 4/2011, revised9/2011
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-701 Job Ref : Z067970 Marked : True Producer : Acrobat Distiller 7.0.5 (Windows) Copyright : 2011, 9/2011 Web Statement : 3A1334, For dispensing non-corrosive and non-abraisve lubricants, oil, grease, and automatic transmission fluids in stationary or mobile installations. Keywords : "LD Series Oil and Grease Pump, 3A1334, Non-corrosive lubricants, non-abrasive lubricants, oil, grease, automatice transmission fluid, 3A1334" Create Date : 2005:04:27 11:19:54Z Creator Tool : FrameMaker 9.0 Modify Date : 2011:10:04 10:32:54-05:00 Metadata Date : 2011:10:04 10:32:54-05:00 Format : application/pdf Title : 3A1334E LD Series Oil and Grease Pump, Instructions, English Creator : Terri Howard Description : For dispensing of non-corrosive and non-abrasive lubricants, oils, grease, and automtiace transmission fluid in stationary or mobile installations. Subject : LD Series Oil and Grease Pump, 3A1334, Non-corrosive lubricants, non-abrasive lubricants, oil, grease, automatice transmission fluid, 3A1334 Document ID : uuid:a7c7ed24-89c4-41db-9f78-8c49ebc14964 Instance ID : uuid:aff9a572-3465-49ea-a0ec-7af3f12a7136 Page Count : 32 Author : Terri HowardEXIF Metadata provided by EXIF.tools