Graco 3A1334E Ld Series Oil And Grease Pump Users Manual Pump, Instructions, English

3A1334E to the manual 9d93a409-77f2-4715-b3a2-c3a21b5ab13d

2015-04-02

: Graco Graco-3A1334E-Ld-Series-Oil-And-Grease-Pump-Users-Manual-686368 graco-3a1334e-ld-series-oil-and-grease-pump-users-manual-686368 graco pdf

Open the PDF directly: View PDF PDF.
Page Count: 32

DownloadGraco Graco-3A1334E-Ld-Series-Oil-And-Grease-Pump-Users-Manual- 3A1334E LD Series Oil And Grease Pump, Instructions, English  Graco-3a1334e-ld-series-oil-and-grease-pump-users-manual
Open PDF In BrowserView PDF
Instructions

LD Series Oil and Grease
Pump

3A1334E
EN

For dispensing non-corrosive and non-abrasive lubricants, oil, grease, and automatic
transmission fluids in stationary or mobile installations. Use with compressed air only. For
professional use only. Not for use with windshield washer fluid.
List of models, including Maximum Fluid Pressure:
• Oil Pump Models: page 2
• Grease Pump Models: page 3

Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.

Related Translated Manuals
Manual Number
3A1339
3A1345
3A1350
3A1360
3A1365
3A1370
3A1375

Language
Spanish
French
German
Russian
Chinese
Japanese
Korean

European Community Design Patent: 001278006-001;
001278006-002
Patents Pending

Oil Pump Models

Oil Pump Models
All oil models include a 2” npt(m) bung adapter.
PN

Description

Max air pressure

Max Fluid Pressure

3:1 PUMPS

psi

Mpa

bar

psi

Mpa

bar

24G576

Universal

150

1.03

10.3

750

5.17

51.7

24G577

Universal

150

1.03

10.3

750

5.17

51.7

24G578

Universal

150

1.03

10.3

750

5.17

51.7

24G579* Multilength

150

1.03

10.3

750

5.17

51.7

24G580* Multilength

150

1.03

10.3

750

5.17

51.7

24G581* Multilength

150

1.03

10.3

750

5.17

51.7

24G582* 200L (55gal) drum

150

1.03

10.3

750

5.17

51.7

24G583* 200L (55gal) drum

150

1.03

10.3

750

5.17

51.7

24G584* 200L (55gal) drum

150

1.03

10.3

750

5.17

51.7

24G585* 1040 liter (275gal) tote

150

1.03

10.3

750

5.17

51.7

24G586* 1040 liter (275gal) tote

150

1.03

10.3

750

5.17

51.7

24G587* 1040 liter (275gal) tote

150

1.03

10.3

750

5.17

51.7

5:1 PUMPS

psi

Mpa

bar

psi

Mpa

bar

24G588

Universal

150

1.03

10.3

750

5.17

51.7

24G589

Universal

150

1.03

10.3

750

5.17

51.7

24G590

Universal

150

1.03

10.3

750

5.17

51.7

24G591* 5:1 Multilength

150

1.03

10.3

750

5.17

51.7

24G592* 5:1 Multilength

150

1.03

10.3

750

5.17

51.7

24G593* 5:1 Multilength

150

1.03

10.3

750

5.17

51.7

24G594* 200L (55gal) drum

150

1.03

10.3

750

5.17

51.7

24G595* 200L (55gal) drum

150

1.03

10.3

750

5.17

51.7

24G596* 200L (55gal) drum

150

1.03

10.3

750

5.17

51.7

24G597* 1040 liter (275gal) tote

150

1.03

10.3

750

5.17

51.7

24G598* 1040 liter (275gal) tote

150

1.03

10.3

750

5.17

51.7

24G599* 1040 liter (275gal) tote

150

1.03

10.3

750

5.17

51.7

Air inlet
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT

Air inlet
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT
1/4"-18
NPT
1/4"-19
BSPP
1/4"-19
BSPT

Fluid
Inlet
1"-11.5
NPT
1-11
BSPP
1-11
BSPT
1"-11.5
NPT
1-11
BSPP
1-11
BSPT
1"-11.5
NPT
1-11
BSPP
1-11
BSPT
1"-11.5
NPT
1-11
BSPP
1-11
BSPT

Fluid
Inlet
1"-11.5
NPT
1-11
BSPP
1-11
BSPT
1"-11.5
NPT
1-11
BSPP
1-11
BSPT
1"-11.5
NPT
1-11
BSPP
1-11
BSPT
1"-11.5
NPT
1-11
BSPP
1-11
BSPT

Fluid
Outlet
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT

Fluid
Outlet
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT
1/2"-14
NPT
1/2"-14
BSPP
1/2”-14
BSPT

* Includes universal pump and down tube, packaged separately.

2

3A1334E

Grease Pump Models

Grease Pump Models
PN

Description

50:1 PUMPS

Max air pressure

Max Fluid Pressure

psi

Mpa

bar

psi

Mpa

bar

Air inlet

Fluid
Inlet

Fluid
Outlet

24G600

16kg (35lb)

150

1.03

10.3

7500

51.7

517

1/4"-18
Npt

Priming
piston

1/4"-18
Npt

24G601

16kg (35lb)

150

1.03

10.3

7500

51.7

517

1/4"-19
BSPP

Priming
piston

1/4"-19
BSPP

24G602

16kg (35lb)

150

1.03

10.3

7500

51.7

517

1/4"-19
BSPT

Priming
piston

1/4"-19
BSPT

24G603

55kg (120lb)

150

1.03

10.3

7500

51.7

517

1/4"-18
Npt

Priming
piston

1/4"-18
Npt

24G604

55kg (120lb)

150

1.03

10.3

7500

51.7

517

1/4"-19
BSPP

Priming
piston

1/4"-19
BSPP

24G605

55kg (120lb)

150

1.03

10.3

7500

51.7

517

1/4"-19
BSPT

Priming
piston

1/4"-19
BSPT

24G606

180kg (400lb)

150

1.03

10.3

7500

51.7

517

1/4"-18
Npt

Priming
piston

1/4"-18
Npt

24G607

180kg (400lb)

150

1.03

10.3

7500

51.7

517

1/4"-19
BSPP

Priming
piston

1/4"-19
BSPP

24G608

180kg (400lb)

150

1.03

10.3

7500

51.7

517

1/4"-19
BSPT

Priming
piston

1/4"-19
BSPT

3A1334E

3

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and
warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may
look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
• Do not point dispense valve at anyone or at any part of the body.
• Do not put your hand over the end of the dispense nozzle.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources, such as cigarettes and portable electric lamps.
• Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
• Ground all equipment in the work area.
• Use only grounded hoses.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until
you identify and correct the problem.
• Keep a working fire extinguisher in the work area.

4

3A1334E

Warnings

WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about
your material, request MSDS forms from distributor or retailer.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical
reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or
property damage.
• Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or
fluids containing such solvents.
• Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier
for compatibility.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area
of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of
toxic fumes, and burns. This equipment includes but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

3A1334E

5

Installation

Installation
NOTE: Reference letters and numbers in parentheses in the text refer to callouts in the figures and drawings.

Grounding

To reduce the risk of static sparking, ground the pump
and all other components used or located in the
dispensing area. Check your local electrical code for
detailed instructions for your area and type of
equipment.

•

Air and fluid hoses: Use only electrically conductive
hoses.

•

Air compressor: Follow manufacturer’s recommendations.

•

Dispensing valve: Ground through connection to a
properly grounded fluid hose and pump.

•

Object being dispensed to: Follow your local code.

•

Solvent pails used when flushing: Follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the pail
on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.

•

To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the dispensing valve firmly to the side of a grounded metal pail,
then trigger the dispense valve.

Ground all equipment:
•

Pump: Use a ground wire and clamp as shown in
FIG. 1.
a. Remove the ground screw (Z) and insert
through the eye of the ring terminal at end of
ground wire (Y).
b.

Fasten the ground screw back onto the pump
and tighten securely.

NOTE: To order a ground wire and clamp, order Graco
Part No. 222011.

Y
Z

ti16123

FIG. 1

6

3A1334E

Installation

Typical Installation
The typical installation shown in FIG. 2 is only an installation guide. It is not an actual system design. Contact your
Graco Distributor for assistance in designing a system to suit your needs.

Stationary Mountings
Recommended
air line
configuration
to reduce
moisture in pump

C

B

E

F

M

F

A
J

G

K

D

H

N

L

ti16120

FIG. 2
Key (FIG. 2)
A
B
C
D
E
F

G

H
J
K
L
M
N

Fluid outlet line (flexible connection required)
Pump
Ground wire
Pump runaway valve
Air lubricator
Bleed-type master air valve (required)
• NPT - Part No. 110223
• BSP - Part No. 125272
Air regulator (self-relieving regulator required)
• NPT - Part No. 24H420
• BSP - Part No. 24H419
Air filter
Main air line
Bung adapter - Part No. 24F918
Fluid inlet line (flexible connection required)
Air inlet line (flexible connection required)
Wall mount bracket - Part No. 24F910

3A1334E

7

Installation

Installation Guidelines

Pump Mounting

Reference letters found in the following instructions,
refer to Typical Installation diagram provided on page 7.

1. Install bung adapter (K) into bung mount/bracket/or
drum cover.

•

A ball valve must be installed upstream of the regulator (G).

2. Install pump (B) into bung adapter (K).

•

The fluid outlet line (A), fluid inlet line (L) and air
inlet line (M) must be flexible (such as a hose).

B

NOTE: To prevent damage to the pump, remove sediment from the bottom of the container before installing a
pump on an existing container.

A

K

aa
The maximum working pressure of each pump in
your system may not be the same. To reduce the risk
of over-pressurizing any part of your system, which
may result in component rupture, fire or explosion
and cause serious bodily injury, be sure you know
the maximum working pressure rating of each pump
and its connected components.
•

Never exceed the maximum working pressure of
the lowest rated component connected to a particular pump.

•

Be sure you know the maximum working pressure
of each component.

•

Do not exceed the maximum pump cycle rate.

•

Regulate air pressure to prevent over pressurization at fluid section of the pump.

•

FIG. 3
Installing Outlet Hose (FIG. 3)
1. Connect the swivel adapter (aa) to the pump fluid
outlet. Tighten securely and torque as recommended below:
•
•

For NPT models: 1 to 1-1/2 turns past hand
tight.
For BSPT models: 1-1/2 to 2 turns past hand
tight.

2. Connect the fluid hose (A) to the swivel adapter
(aa).
3. Connect a suitable dispensing valve or extra hose to
the 6-ft hose.

Regulate air pressure to the pump so that no fluid
line component or accessory is over pressurized.

Stationary Mounting Layout
Plan the layout for easy operator access to the pump air
controls, sufficient room to change drums and a secure
platform.

8

3A1334E

Installation

Air Line and Accessories
NOTE: Install the air line accessories in the order shown
in the Typical Installation on page 7.
NOTICE
Do not hang the air accessories directly on the air
inlet. Mount them on brackets. Always use a flexible
hose between all connections. The air inlet is not
strong enough to support accessories and may cause
one or more to break.
•

Use thread sealant on all male threads except
swivel connections.

•

Install a pump runaway valve (D) to shut off the air
to the pump if the pump accelerates beyond the
pre-adjusted setting. A pump that runs too fast can
be seriously damaged.

•

Install the air regulator (G) to control pump speed
and pressure.
For NPT models order Graco Part No. 24H420 or for
BSP models order Graco Part No. 24H419.

•

Install a bleed-type master air valve (F) upstream
from the pump air regulator (G) but within easy
reach of the pump.
For NPT models order Graco Part No. 110223 or for
BSP models order Graco Part No. 125272.

•

On the main air supply line from the compressor,
install an air line filter (H) to remove harmful dirt and
contaminants from the compressor air supply.

Follow Plate - Grease Models Only
For grease models only a follow plate is required for
pumping fluid from the drum. See page 12 for follow
plate installation instructions.

3A1334E

9

Operation

Operation
Thermal Induced Pressure
Relief (Oil pumps only)

a

THERMAL EXPANSION HAZARD
Fluids subjected to heat in confined spaces, including
hoses, can create a rise in pressure due to the
thermal expansion. Over-pressurization can result in
equipment rupture and serious injury.
Oil pumps have a built-in, thermal induced, pressure
relief as shown in FIG. 4. To ensure system pressure
will automatically bleed excess thermal induced
system pressure through the pump and back to the
oil reservoir:
•

Always use a relieving air pressure regulator to
allow the pump/motor to run backwards. The regulator bleeds excess air pressure.

•

There should not be any obstructions between air
inlet of pump and regulator.

•

There should not be any obstructions between the
downstream plumbing and pump outlet such as
closed ball valves or check valves.

•

There should not be any obstructions between the
pump inlet and fluid container such as closed ball
valves or check valves.

•

Only use Graco designed suction tubes for in-drum
or in-tank applications.

•

Only use Graco designed suction tubes with a
built-in relief device for wall mount applications.

•

Always use an inlet screen to prevent debris from
plugging relief passages from entering the pump.
- Do not operate the pump with out an inlet screen.

•

10

Periodically inspect the inlet screen for plugging.
Graco recommends inspecting the inlet screen
every time the container is changed out.

b

FIG. 4 a = Pump cylinder relief passage
b = Inlet check relief passage

Thermal Relief Theory of Operation
The pump operation is similar to most double acting
reciprocating pumps. The pump only comes to a complete stop on the up stroke. The pump will stroke
through on the down stroke due to the inlet check relief
passage.
Excess pressure due to downstream thermal expansion
causes the air motor/pump to run backwards (downward). Fluid pressure is relieved through the inlet check
relief passage as the pump piston moves downward. Air
pressure is simultaneously relieved through the air inlet
passage. The pump piston moves downward exposing
the pump cylinder relief passage at the bottom of the
stroke. Additional excess pressure is then relieved
through both the inlet check relief passage and the
pump cylinder relief passage.
Pressure is relieved at the pump through the pump inlet
relief passage. The pump will not change over on the
bottom of the stroke as a result of relieving excess pressure due to the positioning of the pump cylinder groove
with respect to the air motor pilot valve.
NOTE:
•

The air supply does not have to be turned off to
enable thermal relief activation.

•

The Thermal Induced Pressure Relief design feature of the pump will cause the pump to dive on the
downstroke when a dispensing valve is closed.
3A1334E

Operation

Install only one pump per delivery system. Do not use
the pumps in a parallel pump installation.

Start-up

Loss of pump prime can occur if all the following events
occur in sequence:

Determining Output Pressure Using the Air
Regulator

1. A thermal relief event occurs.

To determine the fluid output pressure using the air regulator reading, multiply the ratio of the pump by the air
pressure shown on the regulator.

2. The air supply valve is closed.
3. A dispense valve located at an elevation higher than
the tank level, is open.
To prevent loss of prime, ensure the air supply valve is
turned on before attempting to dispense fluid.

Pressure Relief Procedure

The equipment stays pressurized until pressure is
manually relieved. To reduce the risk of serious injury
from pressurized fluid, fluid from the valve, or splashing fluid, follow this procedure whenever you:
•
•
•
•

are instructed to relieve pressure
stop dispensing
check, clean, or service any system equipment
install or clean dispensing devices.

For example a 3:1 ratio oil pump:
3:1 ratio x 100 psi air = 300 psi fluid outlet
A 3:1 pump is capable of 5:1 on the downstroke and will
develop 5:1 pressures under normal operation.
A grease pump has a ratio of 50:1. However it is capable
of reaching a stall pressure equal to 60 times the air
input pressure. To calculate the fluid output pressure
using the air regulator reading, multiply the regulator
gauge by 60.
For example:
140 psi air x 60 = 8400 psi fluid output
0.97 MPa air x 60 = 58.2 MPa
99.7 bar x 60 = 582 bar
Regulate air to the pump so that no air line or fluid line
component or accessory is over pressurized.

Priming the pump
1. Close the pump’s bleed-type master air valve.
2. Close the pump air regulator and disconnect the air
supply hose.
3. Open the dispensing valve and dispense fluid into a
waste bucket/container until pressure is fully
relieved.
If you suspect that the dispensing valve is clogged, or
that pressure has not been fully relieved after following
the steps above, very slowly loosen the dispensing
valve coupler or hose end coupling to relieve pressure
gradually, then loosen completely.

1. Close the air regulators and bleed-type master air
valves to all but one pump.
2. Open the master air valve from the compressor.
3. For the pump that is connected, trigger the dispensing valve into a grounded metal waste container
making firm, metal-to-metal contact between the
container and the valve.
4. Slowly open the bleed-type master air valve and
open the pump air regulator just until the pump is
running. When the pump is primed and all air has
been pushed out of the lines, release the trigger.
5. If you have more than one pump, repeat this process for each pump in your system.
NOTE: When the pump is primed and has sufficient
air supplied to it, it starts when the dispensing valve
is open and shuts off when closed.

3A1334E

11

Operation

Step 6 is for Oil Pumps Only:
6. The thermal relief feature of this oil pump can
increase the amount of time needed to fully prime
the pump when compared to pumps without a thermal relief feature. To minimize this effect, prime the
pump before connecting it to an already primed distribution system.

Changing Grease Drum and Installing
Follow Plate (grease models only)

1. Relieve pressure, page 10.
NOTICE
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately
and check the fluid supply. If the supply container is
empty and air has been pumped into the lines, prime
the pump and lines with fluid, or flush it and leave it
filled with a compatible solvent. Be sure to eliminate
all air from the fluid system.

2. Remove drum cover by loosening thumb screws (a)
(FIG. 5).

a

NOTE: A pump runaway valve can be installed on the
air line to automatically shut off the pump if it starts to
run too fast.
FIG. 5
7. Read and follow the instructions supplied with each
component in your system.
8. When shutting off the system and before checking
or servicing, relieve pressure following pressure
relief procedure, page 10.

3. Remove pump and cover from drum and place on a
clean paper, cardboard, or clean shop rags. DO
NOT PLACE ON SHOP FLOOR.
4. If this is an existing installation, reach into drum and
pull on follow plate ring (b) to remove follow plate
(FIG. 6). Place follow plate on a clean paper, cardboard or clean shop rags. DO NOT PLACE ON
SHOP FLOOR.
Remove drum and install new one.
b

FIG. 6
12

3A1334E

Operation

5. Examine follow plate to make sure rubber grommet
(c) is in place in center of the plate (FIG. 7).

7. Insert pump drop tube through center of rubber
grommet in follow plate (FIG. 9).
Se

c

FIG. 7
6. Set follow plate on top of fresh grease (FIG. 8).
Remove air by pushing on the follow plate until the
grease level is flush with the opening in the middle
of the follow plate (d).
FIG. 9
8. Tighten thumb screws (a) to secure cover to drum.

d

a

FIG. 8

FIG. 10
9. For the pump that is connected, trigger the dispensing valve into a grounded metal waste container
making firm, metal-to-metal contact between the
container and the valve.
10. Slowly open the bleed-type master air valve and
open the pump air regulator just until the pump is
running. When the pump is primed and all air has
been pushed out of the lines, release the trigger.

3A1334E

13

Repair

Repair
Replacing Pilot Valves
Reference letters shown in the following instructions
refer to Typical Installation diagram, page 7. Part numbers refer to the Parts pages beginning on page 15.

1. Stop pump at the middle of its stroke.
2. Relieve pressure, page 11.
3. Disconnect the air line (M).
4. Use a 10 mm socket wrench to remove the old pilot
valve (20).
5. Lubricate o-rings and install the new pilot valve (20).
Torque to 95-105 in-lb (11-12 N.m).

14

3A1334E

Parts

Parts
3:1 Oil Pump Models: 24G576 - 24G587: 5:1 Oil Pump Models: 24G588 - 24G599
Ref

Part No Description

2

116343

Qty

Ref

Part No Description

SCREW, ground

1

40 ▲ 16G243◆ LABEL, safety, warning, multiple

3

SCREW

3

4

SCREW M6 x 22 mm

5

43
50

✿
24F918

O-RING, air piston

1

51

16G121★ STRAINER

O-RING

1

O-RING

1

O-RING,

1

SEAL, u-cup

1

PIN, spring

1

BALL, steel

1

BALL, steel

1

✓

O-RING, (models 24G576 - 24G578)

1

O-RING (models 24G588 - 24G590)
O-RING

1
1

16F951

14

✓
✓

15

✓★

O-RING

1

16F885

SCREW

1

✠

O-RING

3

BOLT M8 X 25

1

5
6
7
8
9

✠
✠
✠
✠
✠

10
11

★

12
13

16
17
18
19
20

◆✖

WASHER, M8 (not shown)

1

VALVE, pilot

2

16F878
16F948

52‡

16F949
16F886
53‡

16F950

54‡

16F962
16F963
✠

55

SCREW, M6 x 25 mm
ADAPTER, bung, LD pump
TUBE, PVC, LD pump (models
24G579, 24G591)
TUBE, PVC, LD pump (models
24G580, 24G592)
TUBE, PVC, LD pump (models
24G581, 24G593)
TUBE, metal, LD pump (models
24G582, 24G594)
TUBE, metal, LD pump (models
24G583, 24G595)
TUBE, metal, LD pump (models
24G584, 24G596)
TUBE, metal, LD pump (models
24G585, 24G597)
TUBE, metal, LD pump (models
243G586, 24G598)
TUBE, metal, LD pump (models
24G587, 24G599)
O-Ring (not shown)

Qty
1
8
1
1
1
1
1
1
1
1
1
1
1
1

21

PISTON, air, plastic

1

22

BEARING, delrin

1

▲ Replacement Danger and Warning labels, tags, and
cards are available at no cost.

❖ †✿ ◆

SEAL, air valve, manifold (not shown)

1

‡ Packaged separately with universal pump.

15M213

MUFFLER, 3/8

1

112933

MUFFLER, quiet (optional)

1

✠

GASKET, cover, small

2

26

COVER, bottom, machining

1

27

CYLINDER air, machined

1

HOUSING, intake valve, machined

1

29
30

FLANGE, oil, machined
ROD, displacement

1
1

❖
†
✿

31

GUIDE, air

1

◆

32

CYLINDER, fluid

1

33
34

PISTON, pump, 3:1, machining
HOLDER, ball

1
1

23
24
25

28

35

15M182

★

★

SPRING, compression

1

36

SPRING, compression

1

37

HOUSING, manifold, machined

1

✿
39 ▲ 16F541

VALVE, air, small
LABEL, identification, lD 3:1

1
1

38

3A1334E

✠
✓
★

✖

Included in kit 24H853
Included in kits 24K293 - 3:1; 24H855 - 5:1
Included in kits 24H611 (npt), 24J430 (bspp) 24J431
(bspt)
Included in kit 24H798
Included in kit 24H851
Included in kit 24H848 (npt), 24H849 (bspp), 24H850
(bspt)
Included in kit 24J757 (npt), 24J758 (bspp), 24J759
(bspt)
Included in kit 24H749

15

Parts

Related Oil Pump Kits

Throat and Piston Seal Replacement Kit 24H853 (FIG. 12)

Kit No.

NOTE: When servicing the throat and piston seals, it is
recommended to also replace seals in the pump lower.
Order repair kit: 24K293 for 3:1 pumps or 24H855 for
5:1 pumps. Instructions related to this kits are included
in instruction manual 3A1494 (included with the kit).

24H611
24J430
24J431

Description

Qty

KIT, repair, intake valve, npt,
includes 11, 15, 28, 35, 51
KIT, repair, intake valve, bspp,
includes 11, 15, 28, 35, 51
KIT, repair, intake valve, bspt,
includes 11, 15, 28, 35, 51

1
1
1

O-Ring Replacement Kit - 24K293 for 3:1
pumps; 24H855 for 5:1 pumps (FIG. 11)
NOTE: When replacing seals in the pump lower also
service the throat and piston seals. Order repair kit
24H853. Instructions related to this kit are included in
instruction manual 3A1494 (included with the kit).
Ref.
13
14
15

Description
O-RING
O-RING
O-RING

Ref.
5
6
7
8
9
17
25
55

Description
O-RING, air piston
O-RING
O-RING
O-RING, wiper
SEAL, u-cup
O-RING
GASKET, cover, small
O-RING (not shown)

Qty.
1
1
1

Qty.
1
1
1
1
1
3
2
1
7

9

5

13

8
14

15
FIG. 11

25

17
6

FIG. 12

16

3A1334E

Parts

Kits
Page 21
20 1
27

18 6

40
39

19

30

10

21
5
3
17
4 31

34
36

3

12
33 5

6
26

13
14

52, 53
or 54,
Page 15

7
1

20
22
32 2
11

9
8

3

35
11

4

15
29
2
1 Torque to 95-105 in lbs (10.7 - 11.9 N•m)
2

Torque to 20 - 25 ft lbs (27- 34 N•m)

3

Torque to 60 - 70 in lbs (6.8 - 7.9 N•m)

4

Torque to 25 - 35 in lbs (2.8 - 3.9 N•m)

5

Torque to 110 - 120 in lbs (12.4 - 13.6 N•m)

6

Torque to 80 - 90 in lbs (9.0 - 10.2 N•m)

11

4

28

51

2
50

Lips face down

3A1334E

17

Parts

50:1 Grease Pump Models: 24G600 - 24G608
Ref

Part No. Description

2

116343 SCREW, ground

Qty

Ref

Part No. Description

Qty

1

34

ROD, priming

1

3

SCREW

3

35

PISTON, shovel, 50:1

1

4

SCREW, M6 X 22 mm

5

36

CYLINDER, spacer

1

O-RING, air piston

1

37

NUT, retainer

1

O-RING (not shown)

1

38

WASHER, 30 OD

1

O-RING

10

39

HOUSING, manifold, machined

1

PIN, straight, slotted, 2.5x16

3

40

VALVE, air, small

1

SCREW

1

41 ▲ 1GH013 LABEL, identification, LD 50:1

1

O-RING

1

42 ▲ 16G243 LABEL, safety, warning, multiple

1

SEAL, u-cup

1

43

O-RING

3

13

WASHER,M8

1

14

COVER, bottom, machining

1

15

PISTON, air, plastic

1

SEAL, air valve, manifold

1

5
6
7
8

+
+
+
+@

9
10
11
12

16

@
+
+

15M182

❖ † ✿◆

+

✿◆

✿

+
@
★

1

112933 MUFFLER, quiet (optional)

1

+

GASKET, cover, small

2

NUT, hex

2

VALVE, pilot

2

◆

21

CYLINDER, air, machined

1

22

FLANGE, bottom cover, grease,

1

✖

23

ROD, piston, 50:1

1

SEAL, piston

1

25

ROD, displacement, 50:1

1

26

CYLINDER, HP 50:1

1

18
19
20

24

◆✖

@

27

24J380 KIT, cylinder, shovel

1

28

@

SEAL, intake

1

RETAINER, seal, al

1

GASKET

2

31

BEARING, throat

1

32

ROD, connection

1

33

GUIDE, air

1

29
30

18

+@

8

▲ Replacement Danger and Warning labels, tags, and
cards are available at no cost.

15M213 MUFFLER, 3/8

17

SCREW, M6 x 25 mm

❖
†
✿

Included in kit 24H854
Included in kits 24H856
Included in kits 24H611 (npt), 24J430 (bspp) 24J431
(bspt)
Included in kit 24H798
Included in kit 24H851
Included in kit 24H848 (npt), 24H849 (bspp), 24H850
(bspt)
Included in kit 24J757 (npt), 24J758 (bspp), 24J759
(bspt)
Included in kit 24H749

3A1334E

Parts

Related Grease Pump Kits
Throat and Piston Seal Replacement Kit 24H854 (FIG. 13)

O-Ring and Seal Replacement Kit - 24H856
(FIG. 14)

Instructions related to this kit are included in instruction
manual 3A1495 (included with the kit).

Instructions related to this kit are included in instruction
manual 3A1495 (included with the kit).

Ref.
5
6
7
8
11
12
18
30
37

Ref.
8
10
24
28
30

Description
O-RING, air piston
O-RING
O-RING
PIN, slotted, straight
SEAL, u-cup
O-RING
GASKET, cover, small
GASKET
NUT, retainer

7

Qty.
1
1
1
3
1
3
2
1
1

Description
PIN, slotted, straight
O-RING
SEAL, piston
SEAL, intake
GASKET

Qty.
3
1
1
1
2

30

18

24
8

11
6
28
8
10

12
FIG. 14

30

37

5
FIG. 13

3A1334E

19

Parts

1 Torque to 95-105 in lbs (10.7 - 11.9 N•m)
3

Torque to 60 - 70 in lbs (6.8 - 7.9 N•m)

7

Torque to 70 - 80 in lbs (7.9 - 9.0 N•m)

8

Torque to 45 - 55 ft lbs (61 - 75 N•m)

9

Torque to 30 - 40 in lbs (3.4 - 4.5 N•m)

20 1

21

41

30
36 8

10 Torque to 30 - 35 in lbs (3.4 - 4.0 N•m)
11

Lips face down

30

42

13

Kits, page 21
7

26 8

19
5
15

8

38
10 37

24

11 11

23

31

1

10
29 8

3
25
12

3

9

28

8

6
33

34

20

14
7
35
19 7

22
3

4
27 8
9

20

2

32

3A1334E

Parts

Oil or Grease Pump Air Valve
Repair and Replacement Kits

Air Valve Seal Kit - 24H851
Ref.

Instructions related to the following kits are included in
instruction manual 3A1496 (included with the kit).

Replace Seals or Rebuild Air Valve Kits

Oil

Grease

23

16

Description

Qty.

SEAL, air valve, manifold

1

381

381

O-RING, 018 buna

2

382

382

SEAL, u-cup, bevel lip

2

383

383

SCREW, M3, thread forming

2

Air Valve Repair Kit - 24H798, Air Valve Seal Kit 24H851 and Air Valve End Cap - 24H852.
382 1

Air Valve Repair Kit - 24H798
Ref.

381

Description

Qty.

16

SEAL, air valve, manifold

1

381

381

O-RING, 018 buna

2

382

382

SEAL, u-cup, bevel lip

2

383

383

SCREW, M3, thread forming

2

386

386

PISTON, air valve

1

387

387

ROLLER, assembly, detent

1

388

388

PLATE, air valve

1

389

389

SPRING, detent, small

1

390

390

CUP, air valve, small

1

391

391

CAM, detent, small

1

Oil

Grease

23

381
391

1 Lips face down
2 Lips face up

382 1

382 2

23/16

1 Lips face down
2 Lips face up

381
FIG. 16

Air Valve End Cap Kit - 24H852
Ref. Description

Qty.

381 O-RING, 018 buna

2

384 PLUG, air valve

2

385 RING, snap

2

381

386
390
387

383

388
384
385

389
FIG. 17

2 382
381
FIG. 15

3A1334E

383
23/16

21

Parts

Air Valve Replacement Kit - 24H848 (npt),
24H849 (bspp), 24H850 (bspt) (FIG. 18)

Pilot Valve Replacement Kit - 24H749
This kit only includes the pilot valves (20). If you
also are repairing/replacing the air valve (38/40) and
air valve seal (23/16) order the Air Motor Service Kit 24J757 (npt), 24J758 (bspp) or 24J759 (bspt).

38/40

Ref.
Description
20 VALVE, pilot

43

Qty.
2

Air Motor Service Kit - 24J757 (npt), 24J758
(bspp), 24J759 (bspt) (FIG. 19)

23/16

I

FIG. 18

38/40

Ref.

Description

Qty.

Oil

Grease

23

16

SEAL, air valve

1

38

40

VALVE, air, small

1

43

43

SCREW, M6 x 25

4

20

23/16
FIG. 19
Ref.

22

Oil

Grease

20
23
40

20
16
40

Description
VALVE, pilot
SEAL, air valve
VALVE, air, small

Qty.
2
1
1

3A1334E

Troubleshooting

Troubleshooting
NOTE: Check all other possible problems and solutions
before disassembling the pump. Before you troubleshoot
problems using the table below, relieve the pressure
and disconnect the pump fluid line. If the pump starts
when the air is turned on again, the fluid line, dispensing
valve, etc. clogged.

Oil Models
Problem

Pump runs but no fluid output

Cause

Solution

Pump is not fully primed

Crack a fitting at the outlet of the
pump to allow a slow leak to purge
any air in the pump. Repeat start up
procedure, page 11.

Oil leakage

Check connection and tighten.

The piston valve is not seating properly or the piston o-ring is damaged

Check and replace parts as needed.

Exhausted fluid supply

Refill and reprime.

The pump inlet filter is blocked

Clear the filter

The suction tube (hose) has an air
leak

Check the connection and tighten as
needed.
Service pilot valve.

Damaged pilot valve

Lower air pressure to prevent reoccurrence.
Replace air valve.

Damaged main air valve
Pump fails to operate or stops

Erratic or accelerated operation

3A1334E

Lower air pressure to prevent reoccur an ce.

Inadequate air supply pressure or
restricted air lines.

Increase air supply; clear.

Closed or clogged dispensing valve

Open valve if closed. Clear clog if
necessary.

Clogged fluid lines, hose valves, etc.

Clear clogs.

Damaged air motor

Service air motor.

Exhausted fluid supply

Refill and reprime.
Replace valve gasket.

Damaged valve gasket

Lower air pressure to prevent reoccurrence.

23

Troubleshooting

Problem

Cause

Solution
Replace gasket.

Intermittent air leakage coming from
behind the air manifold. Pump continues to function normally.

Gasket is leaking

Lower air pressure to prevent reoccurrence.
Clear obstruction.

Thermal relief inlet check relief passage in inlet housing is plugged
Replace inlet filter.
Worn or damaged piston o-ring or
valve cup.
Continuous air exhaust

Pump operates but output is low

Oil leakage through air exhausts

24

Service air motor / valve
Replace valve gasket.

Damaged valve gasket

Lower air pressure to prevent reoccurrence.

Held open or worn intake valve

Clear; service.

Held open or worn pump piston
packings

Clear; service.

The muffler is partially blocked

Clear muffler.

The inlet filter is partially blocked

Clear the filter.

Inadequate air supply pressure or
restricted air lines

Increase air supply; clear restrictions.

Partially closed or clogged pilot
valves

Open valves. Clear clog as necessary.

Partially clogged fluid line, hose,
valves, etc.

Clear clog as necessary.

Throat seal is damaged

Replace throat seal (u-cup).

3A1334E

Troubleshooting

Grease Models
Pump fails to operate

Inadequate air supply pressure or
restricted air lines

Increase air supply and/or clear
restriction.

Closed or clogged pump valves

Open and/or clean.

Clogged fluid line, hose, valve, or
other accessory

Relieve pressure.
Clear obstruction.

Damaged air motor

Assess damage, and service air
motor.

Exhausted fluid supply

Refill and reprime or flush.

Continuous air exhaust

Worn or damaged piston o-ring or
valve cup

Assess wear or damage, and service
air motor.

Erratic pump operation

Exhausted fluid supply

Refill and reprime or flush.

Worn pump seals

Replace.

Damaged shovel tube

Replace.

Damaged check seat

Replace pump piston or shovel rod
(or other damaged part).

Exhausted fluid supply

Refill and reprime of flush.

Fluid too heavy for pump priming

Use inductor or follow plate.

Errataic or accelerated pump speed

Replace valve gasket.

Pump operates but output is low

Grease leaking from muffler

3A1334E

Damaged valve gasket

Lower air pressure to prevent reoccurrence.

Worn piston seal

Replace.

Damaged upper check seat

Replace pump piston.

Worn fluid intake seal

Replace.

Damaged lower check seat

Replace shovel rod.

Inadequate air supply pressure or
restricted air lines

Increase air supply and/or clear
restriction.

Partially closed or clogged pump
valves

Open and/or clean.

Air pockets in the grease inlet

Eliminate the air pockets.

Partially clogged fluid line, hose,
valve, or other accessory

Relieve pressure.
Clear obstruction.

Worn seals

Replace.

Worn throat seal

Replace.

25

Technical Data

Technical Data
3:1 or 5:1 Oil Models
Maximum fluid working pressure

750 psi (51.7 bar, 5.17 MPa)

Fluid pressure ratio

3:1 or 5:1

Suction lift (feet of oil)

10

Air operation range

20 to 150 psi (1.37 to 10.3 bar; 0.137 to 1.03 MPa)

Recommended air pressure for optimum
pump life

<125 psi (8.6 bar, 0.86 MPa)

Air consumption (at 100 psi)

See Performance Curves, page 29

Cycles per gallon/(liter)

3:1 - 29 cycles per gallon (7 cycles per liter); 5:1 - 37 cycles per gallon)
(10 cycles per liter)

Maximum recommended pump speed

3:1 - 120 cycles per minute; 5:1 - 180 cycles per minutes

Recommended speed for optimum pump
life

75 cycles per minute and lower
3:1 - 2.6 gallons per minute (9.8 liters per minute); 5:1 - 2 gallons per
minute (7.6 liters per minute)

Wetted parts

zinc plated carbon, steel, aluminum, nitrile, polyurethane, nickel plated
aluminum

Sound pressure level†*

72.9 dB(a)

Sound power level‡*

82.0 dB(a)

Performance curve

See charts page 28

Approximate weight

3:1 - 7 pounds (3.2 kg); 5:1 - 7.7 pounds (3.5 kg)

Dimensions

See page 30

† Calculated at a distance of 1 meter from measurements taken per ISO 9614-2 @ 100 psi air pressure (6.89 bar,
0.68 MPa) and 20 cycles per minutes.
‡ Measured per ISO 9614-2 at 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minute.
* Muffler 112933 can be ordered separately for reduced sound levels.

26

3A1334E

Technical Data

Dimensions

Model

L
inches (mm)

O
(Overall Length)
inches (mm)

Universal Pump
Only

6.9 (175)

16 (406)

Multi*

42.4 (1076)

51.5 (1307)

Drum

35.7 (907)

44.8 (1138)

Tote

42.8 (1087)

51.9 (1318)

*Multi down tube is angle
cut to the desired length
as required
3/8” (10 mm)
minimum

Multi/Drum/Tote

Universal Pump

a

a

O

d

d

e

e
c

c

L

b
O
a = 1/4 inch air inlet
b = 1 inch fluid inlet
c = 2 inch npt bung adapter
d = ground screw
e = 1/2 inch fluid outlet - opposite of d

L

b
3A1334E

27

Technical Data

Performance Curve
3:1 Oil Models

3:1 Performance Curve
Tested with ISO 46 Hyd Oil

,QOHW$LU3UHVVXUHV

&\FOHVSHUPLQXWH
58

116

174

232
40
(1.1)

300
(20.7)

200
(13.8)

$
$

30
(.8)

%

%

&

20
(.6)

&

100
(6.9)

0

1
(3.8)

2
(7.6)

SVL
EDU

%

SVL
EDU

&

SVL
EDU

10
(.3)

5HFRPPHQGHG2SHUDWLQJ5DQJH

0

$LU)ORZVFIP
PPLQ

)OXLG3UHVXUHSVL
EDU

400
(27.6)

$

3
4
5
(11.4)
(15.1)
(18.9)
)OXLG)ORZJSP
OSP

6
(22.7)

7
(26.5)

8
(30.3)

0
9
(34.1)

5:1 Oil Models

5:1 Performance Curve
Tested with ISO 46 Hyd Oil

,QOHW$LU3UHVVXUHV

&\FOHVSHUPLQXWH
74

148

400
(27.6)
300
(20.7)
200
(13.8)

40
(1.1)

$

$
%

%

28

SVL
EDU

&

SVL
EDU

20
(.6)

&

&

10
(.3)
5HFRPPHQGHG2SHUDWLQJ5DQJH

0

%

30
(.8)

100
(6.9)
0

SVL
EDU

$LU)ORZVFIP
PPLQ

)OXLG3UHVXUHSVL
EDU

600
(41.4)
500
(34.5)

$
222

1
(3.84)

2
(7.6)

3
(11.4)

4
5
6
(15.1)
(18.9)
(26.5)
)OXLG)ORZJSP
OSP

0
7
(26.5)

3A1334E

Technical Data

50:1 Grease Models
Maximum working pressure

7500 psi (517 bar, 51.7 MPa)

Fluid pressure ratio

50:1

Air operation range

20 to 150 psi (1.37 to 10.3 bar; 0.137 to 1.03 MPa)

Air consumption (at 100 psi)

See Performance Curve, page 30

Pump cycles per pound (cycles per kg)

47 cycle per pound (103 cycle per kg)

Maximum recommended pump speed

120 cycles per minute

Recommended speed for optimum pump life 60 cycles per minute or lower flow rate; 1.3 pounds per minute
(0.6 kg per minute)
Wetted parts

steel, brass, nitrile rubber, polyurethane, UHMWPE, acetal

Sound pressure level†*

72.9 dB(a)

Sound power level‡*

82.0 dB(a)

Performance curve

See chart page 30

Approximate weight

35 pound drum - 11.2 pounds (5.1 kg); 120 pound drum - 15.0
pounds (6.8 kg); 400 pound drum - 170.0 pounds (7.7 kg)

Dimensions

See illustration below

† Calculated at a distance of 1 meter from measurements taken per ISO 9614-2 @ 100 psi air pressure (6.89 bar,
0.68 MPa) and 20 cycles per minutes.
‡ Measured per ISO 9614-2 at 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minute.
* Muffler 112933 can be ordered separately for reduced sound levels.

Performance Curve
Grease Models
50:1 Performance Curve
Tested with ISO 46 Hyd Oil

&\FOHVSHUPLQXWH
94

47

8000
(551.6)

,QOHW$LU3UHVVXUHV

)OXLG3UHVXUHSVL
EDU

$

$
%

%

3000
(206.8)
2000
(137.9)

&

&

3A1334E

SVL
EDU

&

SVL
EDU

40
(1.1)

30
(.8)

20
(.6)

10
(.3)

1000
(68.9)
0
0.00

%

$LU)ORZVFIP
PPLQ

50
(1.4)

6000
(413.7)

4000
(275.8)

SVL
EDU

141

7000
(482.6)

5000
(344.7)

$

5HFRPPHQGHG2SHUDWLQJ5DQJH
0.50
(.23)

1.00
(.45)

1.50
(.68)

2.00
2.50
(.91)
(1.13)
)OXLG)ORZOEVP
NJP

3.00
(1.36)

3.50
(1.59)

0
4.00
(1.81)

29

Technical Data

Dimensions
a = 1/4 inch air inlet
b = 1/4 inch fluid outlet
c = 2 inch npt mounting configuration
d = ground screw
a

a

a
d

d

d
c
b

c
b

c
b

23.6 in.
600 mm
14.5 in.
370 mm

37.2 in.
945 mm
28.1 in.
715 mm

36.0 in.
915 mm

45.0 in.
1145 mm

35 pound drum

120 pound drum

400 pound drum

30

3A1334E

Notes

Notes

3A1334E

31

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 3A1334

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2011, Graco Inc. is registered to ISO 9001
www.graco.com
4/2011, revised9/2011



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-701
Job Ref                         : Z067970
Marked                          : True
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Copyright                       : 2011, 9/2011
Web Statement                   : 3A1334, For  dispensing non-corrosive and non-abraisve lubricants, oil, grease, and automatic transmission fluids in stationary or mobile installations.
Keywords                        : "LD Series Oil and Grease Pump, 3A1334, Non-corrosive lubricants, non-abrasive lubricants, oil, grease, automatice transmission fluid, 3A1334"
Create Date                     : 2005:04:27 11:19:54Z
Creator Tool                    : FrameMaker 9.0
Modify Date                     : 2011:10:04 10:32:54-05:00
Metadata Date                   : 2011:10:04 10:32:54-05:00
Format                          : application/pdf
Title                           : 3A1334E LD Series Oil and Grease Pump, Instructions, English
Creator                         : Terri Howard
Description                     : For dispensing of non-corrosive and non-abrasive lubricants, oils, grease, and automtiace transmission fluid in stationary or mobile installations.
Subject                         : LD Series Oil and Grease Pump, 3A1334, Non-corrosive lubricants, non-abrasive lubricants, oil, grease, automatice transmission fluid, 3A1334
Document ID                     : uuid:a7c7ed24-89c4-41db-9f78-8c49ebc14964
Instance ID                     : uuid:aff9a572-3465-49ea-a0ec-7af3f12a7136
Page Count                      : 32
Author                          : Terri Howard
EXIF Metadata provided by EXIF.tools

Navigation menu