Grand Mate RFC Remote Control Transmitter User Manual

Grand Mate Co., Ltd Remote Control Transmitter

User manual

Download: Grand Mate RFC Remote Control Transmitter User Manual
Mirror Download [FCC.gov]Grand Mate RFC Remote Control Transmitter User Manual
Document ID1199794
Application IDNvoMQOc6BlZFNF+WXpAFOQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.49kB (256087 bits)
Date Submitted2009-11-14 00:00:00
Date Available2009-11-14 00:00:00
Creation Date2009-10-15 19:21:06
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2009-10-21 14:56:09
Document TitleRFC 遙控器 功能規格書
Document CreatorAcrobat PDFMaker 8.1 for Word
Document Author: Test User

關
隆
股
份
Grand
有
Mate
限
公
司
Co.,Ltd
RFC remote functional spec. sheet
Revision Control
REV
DATE
REV. BY:
Detail of Revision
D01
2009/07/31 Alvin
New Rule
D02
2009/08/20 Alvin
Change:(1.3.3) ;(1.3.4) ;(2.1.2.2)(2.1.2.3)
(2.2.2);(2.2.3);(2.3.1) ;(2.4.1)
Add: (2.8);(2.9);(2.10);(2.11)(3.0)
1.
D03
2009/8/21
Alvin
Change: (2.8.1);(2.9.1)
D04
2009/8/24
Alvin
Change: (2.1.1);(2.8.1);(2.9.1);(3.4)
Specification:
1.1: Power Supply:
1.2:
AAA 1.5V *3
RF module: 315 MHz
1.3: Remote Keys :
1.3.1: ON▲
1.3.2: OFF▼
1.3.3: TEMP(Left)
1.3.4: FUNC.(Righ)
(ON▲)
(TEMP)
(FUNC.)
1.4: Range:
12.7 meter radius
(OFF▼)
1.5: Certificate Require:
1.5.1: CSA
1.5.2: FCC
1.5.3: IC
關
隆
股
份
Grand
2.
有
Mate
限
公
司
Co.,Ltd
Function
2.1: Flame Adjustment: Adjust flame Hi and Low
ICON:
2.1.1
Steps: 4 steps(include OFF)
ON(Hi)
Middle
Low
OFF(Shot off)
2.1.2 Flow Chat:
2.1.2.1: Press ON▲ → system will proceed ignition process
2.1.2.2: After ignited can use FUNC. Key to select flame function then use ON▲, or
OFF▼ to adjust the flame Hi/Low
2.1.2.3: Press OFF▼ to shut down the system( flame ICON will turn off)
2.2:
Constant Temp. Mode: Auto sense environment temp., it will turn on or shut off
ICON:
2.2.1: Temp. setting Range: 50°F~95°F (10℃~35℃)
2.2.2: Flow Chat:
2.2.2.1: Press TEMP. Key→ into constant temp. mode (will indicate temp. setting mode)
2.2.2.2: When set temp appear, use ON▲ or OFF▼ to adjust the temp.
2.2.2.3: Press TEMP→ shut off the constant temp mode
2.2.2.4: When system into the constant temp. mode, the system will not shut off (always
standby)
2.2.3: Logic:
2.2.3.1: SET TEMP > ROOM TEMP 4°F →
2.2.3.2: SET TEMP < ROOM TEMP 4°F →
System auto off
System auto on
關
隆
股
Grand
份
有
Mate
限
公
司
Co.,Ltd
2.3: ℃ / °F Switch: the Temp. indicator icon can be change
ICON:
2.3.1: Flow Chat:
2.3.1.1: Battery input→ the screen appear °F ICON
2.3.1.2: When ℃ / °F appear, use ON▲, or OFF▼
To chose ℃ or °F
2.3.1.3: Without press any key, the display will back to normal after 5 sec.
2.4 Children Lockout: Lock the entire bottom to prevent child accident turn on the
fireplace
ICON:
2.4.1: Flow Chat:
2.4.2:
Into Children Lockout Function:
Press ON▲ and OFF▼ at same time for 3 sec.
2.4.3:
Disarm Children Lockout Function:
When system is in the lockout mode, press ON▲
And OFF▼ for 3 sec. to disarm
2.5 Low Power Indicate: When battery power is not enough, the system will self detect
ICON:
2.5.1 When battery power is lower than 3.5VD, the system will indicate low power ICON
關
隆
股
Grand
份
有
Mate
限
公
司
Co.,Ltd
2.6 Back Light
2.6.1: When press any key, the back light will turn on
2.6.2: The back light will turn off without touch any key for 5 sec.
2.7 FUNC. Key: Functional Option
2.7.1: Flow Chat:
2.7.1.1: Press FUNC. Once, the display will appear one function
2.7.1.2: The function option as follow:
Flame → Fan → AUX → Light →TIMER
2.8 Fan Function: to control fan levels
ICON:
2.8.1 Level: 4 level( include OFF)
HI
MED
LOW
OFF
2.8.2 Flow Chat:
2.8.2.1: Press FUNC. , Chose
2.8.2.2: When FAN ICON chose appear on the screen, use ON▲ or OFF▼ to adjust the level
of the fan
關
隆
股
Grand
份
有
Mate
限
公
Co.,Ltd
2.9 AUX function: ON/OFFF Add On Module
ICON:
2.9.1 Switch:2
ON
OFF
2.9.2 Flow Chat:
2.9.2.1: Press FUNC. Key ,Chose AUX ICON, then use ON▲, or
OFF▼ to turn on or off the AUX function
2.10 ROOM TEMP Function: Indoor Temp. detect
ICON:
2.10.1: ROOM TEMP Detect and Display
2.10.1.1 Detect: Every 30 seconds detect once
2.10.1.2 Display: Every minute refresh the LCD DISPLAY once
2.11 TIMER Function: Shut off Timer
ICON:
2.11.1 Step: Total 9 steps, every step add 10 min.
2.11.2 Flow Chat:
2.11.2.1: Press FUNC. key ,chose TIMER ICON, use ON▲, or
OFF▼ to chose the setting times
2.11.3: Display
2.11.3.1: When system into TIMER function, it will stay on until the time run out
司
關
隆
股
Grand
份
有
Mate
限
公
司
Co.,Ltd
3. LCD DISPLAY
3.1: Turn on: (ON): Appear use ICON and ROOM TEMP
DISPLAY:
3.2: Turn off: (OFF): only appear ROOM TEMPÆ Shut off all the icon after 3 minutes
DISPLAY:
關
隆
股
Grand
份
有
Mate
限
公
司
Co.,Ltd
3.3: Children Lockout: Into Children Lockout mode, the display will only appear Children
lockout ICON (will remain on until disarm)
DISPLAY:
3.4: Standby Mode:
3.4.1 Shut Off:
When system shut off after 3 min. into standby mode, the LCD will not appear any
icon, press any key to wake up the system (Children lockout will be exceptional)
3.4.2 Turn On:
When system turn on after 3 min. the system will into standby mode, only appear
the icon is use (No appear environment temp.)
3.5:
You are cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void your authority to operate the equipment.
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation
of the device

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Company                         : Test Computer
Source Modified                 : D:20091002095843
Creator Tool                    : Acrobat PDFMaker 8.1 for Word
Modify Date                     : 2009:10:21 14:56:09+08:00
Create Date                     : 2009:10:15 19:21:06+08:00
Metadata Date                   : 2009:10:21 14:56:09+08:00
Document ID                     : uuid:cb7914e7-afd7-4892-9ba8-1180bf2f5ed1
Instance ID                     : uuid:5d97cee7-75e7-4d9a-b389-d1cdf500b734
Subject                         : 9
Format                          : application/pdf
Creator                         : Test User
Title                           :            RFC 遙控器 功能規格書
Page Count                      : 7
Page Layout                     : OneColumn
Author                          : Test User
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UMP-RFC

Navigation menu