Grandway Technology MD41WX Digital Automatic Blood Pressure Monitor User Manual MD41W0 N3b Manual

Grandway Technology (Shenzhen) Limited Digital Automatic Blood Pressure Monitor MD41W0 N3b Manual

User Manual

Download: Grandway Technology MD41WX Digital Automatic Blood Pressure Monitor User Manual MD41W0 N3b Manual
Mirror Download [FCC.gov]Grandway Technology MD41WX Digital Automatic Blood Pressure Monitor User Manual MD41W0 N3b Manual
Document ID3728401
Application IDF6w/bl8iiMVBQsWlzI8Ecw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize81.4kB (1017477 bits)
Date Submitted2018-01-25 00:00:00
Date Available2018-01-26 00:00:00
Creation Date2017-10-11 11:57:40
Producing SoftwareAdobe PDF library 15.00
Document Lastmod2017-10-11 11:57:40
Document TitleMD41W0-N3b-Manual
Document CreatorAdobe Illustrator CC 2017 (Macintosh)

DIGITAL AUTOMATIC
BLOOD PRESSURE MONITOR
USER MANUAL
MODEL : MD41W0/MD41W1
INTRODUCTION
Thank you for purchasing this blood pressure monitor. Please read this manual thoroughly before use. Contact
your physician if you have any queries about your blood pressure.
This fully automatic instrument utilizes the non-invasive oscillometric method, which detects your blood
movement through you brachial artery, for measuring your blood pressure and pulse rate, and the result will
display on a digital panel. Without using a stethoscope, you can get the readings promptly and easily.
This device conforms to European Council Directive 93/42/EEC concerning medical devices. This is made
evident by the CE mark of conformity accompanies by the reference number of the designated authority.
This device complies with :
• EN ISO 81060 standard relating to non-invasive sphygmomanometers Part 1: Requirements and test methods
for non-automated measuremnt types and EN 1060 standard relating to non-invasive sphygmomanometers
Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems.
• EN 60601 standard relating to medical electrical equipment – Part 1-2: General requirements for basic safety
and essential performance and essential performance – Collateral standard: Electromagnetic compatibility –
Requirements and tests.
• EN 1060-4:2004 standard relating to non-invasive sphygmomanometers - Part 4: Test procedures to determine
the overall system accuracy of automated non-invasive sphygmomanometers.
• ISO 81060-2:2013 standard relating to non-Invasive sphygmomanometers - Part 2: Clinical validation of
automated measurement type.
• IEC 80601-2-30:2009+A1:2013 standard relating to medical electrical equipment - Part 2-30: Particular
requirements for the basic safety and essential performance of automated type non-invasive
sphygmomanometers.
Indication for Use
This device is for use by medical professional or home users. It is intended to measure the systolic and diastolic
blood pressure of an adult individual by using a non-invasive technique, in which an inflatable cuff is wrapped
around the upper arm.
SAFETY NOTES
WARNING
WARNING indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided,
may result in minor or moderate injury.
WARNING
• Consult your physician before starting to measure your blood pressure.
• Like any oscillometric blood pressure measurement devices, certain medical conditions can affect the
measurement accuracy, among others:
- Disorder of the cardiac rhythm
- Very low blood pressure
- Very low blood perfusion
- Patients in shock
- Diabetes
- Vessel anomalies
- People with electrical implants such as a cardiac pacemaker
- Women who are pregnant
- Patient who are pre-eclamptic
- Patient motion during measurement
Due to their condition the oscillometric measurement method can produce incorrect readings. This represents a
risk for your health, since values may be interpreted incorrectly. Always consult your physician to determine
what will be suitable for you.
• This product does not and is not intended to provide a medical diagnosis. Measurement results are for
reference only. Self-diagnosis and treatment, e.g. regarding medication, using measured results represents a risk
for your health. Always consult with a licensed physician for determination of appropriate medication and
dosage thereof. Follow the instructions of your physician or licensed healthcare provider.
SAFETY NOTES
• Please note that technically related measuring tolerances are possible. Please see the section “TECHNICAL
SPECIFICATION”.
• Any cuff related blood pressure measurement in high repetition rates, can lead to severe measurement side
effects, e.g.
- A nerve compression with temporary wrist/ hand paralysis
- The release of an arterial or venous thrombus, which can cause a life threatening situation.
Please contact your physician about the specific risks of cuff pressure in your specific case.
• The “irregular heartbeat” function does not replace a cardiac examination, but may help to detect potential heart
rate irregularities at an early stage. Always consult your physician to determine what will be suitable for you.
• The “irregular heartbeat” function is not designed for diagnosing or treating an arrhythmic disorder. Arrhythmia
can only be ascertained by a licensed physician.
• The “WHO BLOOD PRESSURE CLASSIFICATION” chart is not intended to replace a medical diagnosis. This
chart is only for reference for different classifications of blood pressure.
• If you notice abnormal or suspicious variations in blood pressure measurements, consult your physician
immediately.
• Women who underwent a breast or axillaries lymph node removal operation should consult a physician or
licensed healthcare provider before starting blood pressure measurements.
• This device must be used in accordance to the specified ambient conditions, otherwise the accuracy of readings
might be affected. See “TECHNICAL SPECIFICATION” for details.
• Do not wrap the cuff around body parts other than your upper left arm. Misuse represents a risk to your health.
• This product is not intended for use by or on children, toddlers and infants or on persons who cannot express
their consent, e.g. persons with mental disorders or the like. Consult your physician for alternative methods of
measuring a child’s blood pressure.
• Packaging materials are a deadly hazard for children and can cause suffocation. Remove all packaging
materials immediately and keep them away from children at all times.
• This product contains small parts that may present a choking hazard to children. Keep the unit and all parts out
of reach of children.
SAFETY NOTES
• Proper cuff size is important for accurate measurements. Only use the device on adults who have the right
upper arm circumference for this unit. See “TECHNICAL SPECIFICATION” for suitable arm circumferences.
• Electromagnetic interference: Avoid strong electrical or electromagnetic fields in the direct vicinity of the device
(e.g. mobile phones, microwave ovens) while it is in operation, an inaccurate measurements may result. To
prevent such interference, use the unit at a sufficient distance from such devices or turn the disturbances off.
• Batteries should not be charged or reactivated by any other means. The batteries may explode.
• Take extra precaution to keep a leaking battery away from fire as there is a risk of ignition or explosion.
• In case battery fluid leaks and come into contact with your eyes or skin, do not rub and immediately rinse with
plenty of clean water and seek medical advice.
• Do not use the equipment where flammable gas (e.g. anaesthetics gas, oxygen or hydrogen) or flammable
liquid (e.g. alcohol) are present.
• Do not use any cuffs and accessories other than those explicitly recommended by the manufacturer for use with
this product. Cuffs and accessories not approved for use with this device may cause damage to your health and
to the product.
• The tubing presents a strangulation hazard. Keep this product away from children and those who require close
supervision, e.g. people with mental disorders.
• Do not drape tube around neck. This presents a strangulation hazard.
SAFETY NOTES
CAUTION
• This device should not be used when your arm has been wounded/ injured or when a catheter has been
inserted. Such use may result in injury.
• Remove any kind of arm jewellery or the like before taking a measurement. This could cause bruises.
• Do not place the arm cuff over heavy clothing (e.g. a jacket or sweater sleeve) as the blood pressure monitor
will not be able to take a proper measurement and there is an elevated danger of acquiring hematoma or skin
marks during the course of the measurement.
• In case the cuff does not stop inflating, interrupt the measurement by pressing the ON/OFF button and open the
cuff at once.
• In case battery fluid leaks, do not touch the battery fluid. Avoid skin contact (e.g. put on protective gloves) and
clean the battery compartment with dry cloth.
• Do not disassemble the device, it may cause damage to yourself and to the product. If you cannot fix the
problem using the “TROUBLESHOOTING” instructions, request service from your dealer.
• When applying the cuff, make sure there are no wrinkles in the cuff as this could cause bruises.
• Blood pressure measurements can lead to temporary marks on the skin at the site of the cuff placement. This is
especially the case in high repetition rates, in hypertonic patients and in patients with weak heart rates. In rare
cases a mark may persist for couple of days. Please contact your physician about these specific risks of cuff
pressure in your specific case.
• Do not exert any kind of pressure on the hose during measurement, e.g. laying your arms or any other object on
the hose. This could cause incorrect measurements.
MAINTENANCE AND STORAGE
• The blood pressure monitor is constructed by precision electronic components. Accuracy of readings and the
instrument’s service life depend on careful handling. Protect the unit against hard knocks (e.g. dropping the unit),
moisture, water, dirt, dust, chemicals, extreme hot or cold temperatures, major temperature fluctuations, direct
exposure to sunlight and heat sources which are too close (e.g. stoves, heating radiators). This may damage the
unit. The device must be stored in the specified ambient conditions. Please see section “Technical Specification”
for details.
• The device is designed and manufactured for a long service life. However it is generally recommended to have the
monitor inspected every 2 years to ensure proper functioning and accuracy. Please contact your dealer for
maintenance.
• Never immerse and/or spill water or any other liquid onto the monitor or any components, otherwise liquid may
enter it and cause damage.
• Never use rechargeable batteries. This may damage the unit.
• Replace all batteries at the same time and use batteries of the same type. Do not mix old and new batteries.
• Never attempt to repair, open and/or disassemble the unit or adjust it yourself. This may cause damage to the unit
and impair functions. If you cannot fix the problem using the “TROUBLESHOOTING” instructions, request service
from your dealer.
• Do not drop or insert any object into any openings or hoses. This may damage the unit.
• Do not press the buttons with excessive force or with pointed objects.
• Clean your device and cuff carefully only with a slightly moistened soft cloth and dry it immediately with a soft dry
cloth. Do not press.
• Do not use any aggressive solvents, cleaning agents, detergents or any other strong chemicals (e.g. thinner,
alcohol, benzene) to clean the device.
• When storing the device, make sure that no heavy objects are placed on top of it.
• Do not fold the cuff and tubing tightly. The cuff tube should not have any sharp kinks and keep it away from sharp edges.
• Leaking batteries may damage the unit. If you do not intend to use the unit for longer periods, remove the batteries
from the battery compartment before placing the device in storage.
• Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed according
to applicable local regulations for material disposal. Unlawful disposal may cause environmental pollution.
PART IDENTIFICATION
Air Connector Plug
Display
Arm Cuff
DC Jack
Index Mark
Air socket
Air Hose
Increase
Decrease
Memory Button
Button
Button
Button Operations
• Go to standby mode
Press
button.
* The device goes to clock mode if idle for 2 min.
Battery Door
• Recalling average data
Press
button.
• Select between different users
(User 1 / User 2 / User 3 / User 4)
Press [ < ] or [ > ] button
Start / Stop
Button
DISPLAY READINGS
WIFI Transmission Icon
Low Battery Indicator
Communicating Icon
Alarm 1
Alarm 2
Severe Hypertension
Moderate Hypertension
Date
Time
Mild Hypertension
Pressurizing
Releasing Air
Systolic Pressure
Memory
Average of Previous
Measurement
High Normal
USER
Normal
Diastolic Pressure
Optimal
Irregular Heartbeat
Indicator
Pulse Rate
CLOCK MODE & STANDBY MODE
Clock Mode
Standby Mode
INSTALL/ CHANGE BATTERIES
1. Push the battery cover located on the bottom side on
the unit as shown in the figure.
2. Remove old batteries and insert new ones. Use LR03 or
AAA alkaline batteries and use batteries of the same type
only.
3. Make sure the battery polarities (+) and (-) match the
making on the battery compartment.
4. Place back the battery door.
NOTE:
• Insert the batteries as shown in the battery
compartment. If not, the device will not work or even be
damaged.
• When battery power becomes weak, the [
] icon and
“E6” appear in the display, replace all batteries with
new ones. Do not mix old and new batteries.
• Never use rechargeable batteries. This may damage the
unit.
• Battery life may vary with ambient temperature and may
be shorter at low temperature.
10
USE OPTIONAL AC ADAPTOR (Accessory item sold separately)
1. Insert the AC adapter cord into the socket on the right side of the device.
2. Insert the AC adapter plug into the outlet.
3. To remove the AC adapter, first disconnect the adapter plug from the AC outlet, then the adapter cord from the
device.
NOTE:
• Optional AC adaptor should comply with the requirement of IEC 60601-1 standard.
• Use only the exclusive AC adapter specified by authorized dealers. Other AC adapter may vary in output voltage
and polarities and may represent a risk on your life and damaging the device.
• When the AC adapter is in use, the device does not draw power from batteries.
11
TO SET CLOCK / WIFI
After inserting batteries or press and hold [ ] button for 5 sec to enter clock setting mode
1. "Year” will blink on display automatically
2. Press [<] / [>] button to select year
3. Press [ ] button to confirm and "Month" will blink
4. Press [<] / [>] button to select month
5. Press [ ] button to confirm and "Day" will blink
6. Press [<] / [>] button to select day
7. Press [ ] button to confirm and "Hour" will blink
8. Press [<] / [>] button to adjust to desired hour
9. Press [ ] button to confirm and "Minute" will blink
10. Press [<] / [>] button to adjust to desired minute
Press [<] / [>] button to select WIFI on or off
11. Press [ ] button to confirm
12. “
” WIFI icon is displayed and “ ” will blink
13. Press [<] / [>] button to select WIFI on or off.
Press [<] and [>] button
14. Set the WIFI to “On” mode, press and hold
for 3 seconds to enter
[<] and [>] buttons for 3 seconds to enter “AP” mode.
“AP” mode.
15. “AP” is shown and “
” WIFI icon will blink.
16. Install and open the application (APP) - G.LAB fit
Install the
on your smartphone or tablet. Go to the setting manual
application
and click [Change WIFI network].
(APP) 17. The APP will search and list all the available signal.
G.LAB fit.
Select your blood pressure monitor on the list. After
connected to your WIFI network, the “
” icon on
the blood pressure monitor will turn on and stop
blinking, settings are done.
Note: Please repeat the above steps when using new WIFI network.
12
TO SET ALARM CLOCK
1. To enter the alarm clock setting mode, press and hold [
] button until Alarm 1 [
] icon or Alarm 2 [
icon is flashing on the display. Press [<] / [>] to select between [ ] and [ ]. Press [M] button to confirm your
selection.
2. [On] or [OF] icon will blink, press [<] / [>] button to switch between ON and OFF. Press [M] button to confirm.
3. When [On] icon is selected, “Hour” will blink. Press [<] / [>] button to adjust to desired hour. Press [M] button to
confirm.
4. “Minute” will blink. Press [<] / [>] button to adjust to desired minute. Press [M] button to confirm and settings
are done. The alarm icon is turned on on the display.
5. To turn off the alarm, enter the alarm clock setting mode and select the desired alarm icon. Press [M] button to
confirm your selection. Press [<] / [>] button to switch to [OF] and press [M] button to confirm. The alarm is
turned off.
13
TO APPLY ARM CUFF
1. Pass the end of the cuff furthest from the tubing through the metal ring to form a loop. The smooth cloth should
be the inside of the cuff loop.
2. Put your left arm through the cuff loop. The bottom of the cuff should be approximately 2 – 3 cm above the
elbow. The white artery mark on the cuff should lie over the brachial artery on the inside of the arm. The tube
should run down the centre of arm and even with the middle finger. Do not place the arm cuff over heavy
clothing (e.g. jacket or sweater sleeve) as the blood pressure monitor will not be able to take proper
measurement. Blood circulation in the arm should not be restricted by tight clothing or other objects.
3. Pull the cuff so that the top and bottom edges are fitted evenly around your arm.
2-3 cm
4. When the cuff is positioned correctly, press the sewn hook material firmly against the pile side of the cuff.
5. Make sure the cuff fits snugly around your arm. The cuff should make good contact with your skin.
6. If the cuff is assembled correctly, the sewn hook material will be on the outside of the cuff loop and the metal
ring will not touch your skin.
7. Insert the cuff tubing into the socket on the left side of the unit. Make sure it is inserted firmly in the main unit
that there are no kinks in the cuff tubing.
14
BEFORE MEASURING BLOOD PRESSURE
1. Applying the arm cuff, following the instruction in “TO APPLY ARM CUFF”.
2. Rest at least for 5 minutes before each measurement. Otherwise there may be
erroneous results.
3. Sit comfortably on a chair with your feet flat on the floor. Do not cross your feet.
Place your left arm on a table so the cuff is level with your heart.
4. Relax your arm and turn your palm upward.
5. Relax, keep still and do not talk during the measurement in order not to distort
the result.
NOTE:
• This instrument is intended for use on and by adult only. Do not use this device
on or by children, toddlers and infants.
• For reliable monitoring and reference of blood pressure, it is recommended to do
the measurement daily at the same time.
• In order to obtain a resting condition blood pressure, do not take alcoholic and
caffeinated beverages, smoke, exercise or bath for at least 30 minutes before
taking a measurement.
• To minimize measurement variations due to physical activity, relax for five to ten
minutes before taking a measurement. If you are excited by emotional stress or
muscular movement, the measurement result may be inaccurate.
• You should not be physically tired or exhausted while taking measurement.
• Perform measurements in a quiet and relaxed environment at room temperature.
• Remain relax, still and do not speak during measurement since the accuracy of
any blood pressure measurement with this device can be affected by those
multitude of causes.
• Always wait at least 5 minutes between measurements to allow the blood circulation in your arm to return to
normal. You may need to increase the waiting time depending on your individual physiological characteristic.
• Should the device detect an abnormal condition, it stops the measurement and will display an error code. See
“TROUBLESHOOTING” for more details.
• This device measures blood pressure based on heartbeat. If you have a very weak or an irregular heartbeat, the
device may have difficulty in determining your blood pressure. (An irregular heartbeat is defined as a heartbeat
that varies by 25% from the average of all heartbeats during measurement.)
• Do not exert any kind of pressure on the air tube during measurement, e.g. laying your arm or any other object
on the air tube. This could cause incorrect measurements.
15
TO MEASURE YOUR BLOOD PRESSURE
1. Follow the instruction in “BEFORE MEASURING BLOOD
PRESSURE” to make yourself ready.
2. Press [
] button to turn the device from clock mode to
standby mode.
3. Press [<] / [>] to select user memory 1,2,3 or 4. Confirm
selection by pressing [ ] button. Then press [ ] to start the
measurement.
OR
Press [ ] second time to start the blood pressure
measurement.
4. The cuff starts to inflate. It is normal for the cuff to feel very tight.
A pressure bar indicator is displayed during measurement. See
“PRESSURE BAR INDICATOR” for more details.
5. Once the pulse is detected, the [ ] blinks with each pulse beat,
indicating that the measurement is in progress.
6. When the measurement is complete, the systolic and diastolic
pressure and pulse rate are displayed and stored.
NOTE:
You can stop inflation by pressing [
] button at any time.
16
Deflation for start measuring
Record number and
User ID are displayed
Inflation in progress
Measurement result shown
PRESSURE BAR INDICATOR
The indicator monitors the progress of pressure during measurement.
Pressurizing
Measurement in progress
17
WHO CLASSIFICATION INDICATOR
Each of the six segments of the bar indicator corresponds to the WHO blood pressure classification.
WHO Classification Indicator:
Severe Hypertension
Moderate Hypertension
Mild Hypertension
High Normal
Normal
Optimal
18
TO RECALL AVERAGE AND PREVIOUS MEASUREMENT DATA
This device has a memory capability to store the measurement readings for each user. Every time you complete
the measurement, the device automatically stores the measurement result.
1. Press [
] button in standby mode to enter the memory mode, the average blood pressure for the latest 3
measurements is displayed.
2. Press [>] button to view average data for lastest 7 days AM record (5:00 - 9:00 am).
3. Press [>] button to view average data for lastest 7 days PM record (6:00 - 8:00 pm).
4. Press [>] button to view the lastest measurement record.
5. Continue to press [>] button to view older measurement records.
6. Press [<] button to view previous measurement records.
19
TO DELETE MEASUREMENT DATA
1. Press [ ] button simultaneously when the device is showing average or previous
measurement data of selected user.
2. Press and hold [ < ] and [ > ] for 3 seconds until [CL] and [00] are shown.
3. All measurement data for the selected user will be deleted.
Press and hold
[ < ] and [ > ] at
the same time
Press [
All memories cleared
20
CONTROL WITH YOUR VOICE
Amazon Echo includes Alexa can be used to give commands to the blood pressure monitor.
Connecting the blood pressure monitor to Alexa:
1. On your smartphone or tablet, download the Amazon Alexa app from your app store.
2. Open the Alexa app and log in to your amazon.com account.
3. Select “Skills” from the menu and search for “G Doctor” skill.
4. Plug the AC adaptor to the blood pressure monitor.
(Ref. to “USE OPTIONAL AC ADAPTOR” )
5. Connect your blood pressure monitor to your WIFI network.
(Ref. to “TO SET CLOCK / WIFI” )
6. Open the G.LAB fit app and select “Smart Home” from the setting menu. Turn on the
communicating function, the “ ” icon will be shown on the blood pressure monitor.
Giving voice commands
When using the skill, you need to specify the name which the blood pressure monitor use and also specify the
user ID. Use the blood pressure monitor name(s) you set up already. These are shown in the G.LAB fit app.
(Setting > Smart Home)
The preset name of blood pressure monitor is “BPM” and the preset user ID is “user 1”. To give voice
commands to the blood pressure monitor, please say “ Ask - BPM ” + below skill:
To check the last measurement record:
To check the average measurement record:
• “Ask (BPM) get (user 1) last reading”
• “Ask (BPM) get (user 1) average reading”
• “Ask (BPM) what is (user 1) last reading”
• “Ask (BPM) what is (user 1) average reading”
• “Ask (BPM) give me last data of (user 1)”
• “Ask (BPM) give me average data of (user 1)”
• “Ask (BPM) find last reading of (user 1)”
• “Ask (BPM) find average data of (user 1)”
• “Ask (BPM) give me (user 1) last data”
• “Ask (BPM) give me (user 1) average data”
21
WHAT IS AN IRREGULAR HEARTBEAT
This blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular
heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all
heartbeats during the blood pressure measurement. It is important that you are relaxed, remain still and do not
talk during measurements.
NOTE:
• We recommend you to contact your physician if you see this [
] indicator frequently.
• The “irregular heartbeat” function does not replace a cardiac examination, but may help to detect potential heart
rate irregularities at an early stage. Always consult your physician to determine what will be suitable for you.
• The “irregular heartbeat” function is not designed for diagnosing or treating an arrhythmic disorder. Arrhythmia
can only be ascertained by a licensed physician.
22
ABOUT BLOOD PRESSURE
What Is Blood Pressure?
Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the
heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of
mercury (mmHg). One’s natural blood pressure is represented by the fundamental pressure, which is measured
first thing in the morning while one is still at rest and before eating.
What Is Hypertension And How Is It Controlled?
Hypertension, an abnormally high arterial blood pressure, if left unattended, can cause many health problems
including stroke and heart attack. Hypertension can be controlled by altering one’s lifestyle, avoiding stress, and
with medication under a doctor’s supervision. To prevent hypertension or to keep it under control:
• Do not smoke
• Exercise regularly
• Reduce salt and fat intake
• Have regular physical checkups
• Maintain proper weight
Reference Material: Journal of Hypertension 1999, Vol 17 No.2
mmHg
Diastolic blood pressure
Why Measure Blood Pressure At Home?
Blood pressure measured at a clinic or doctor’s
office may cause apprehension and can produce
an elevated reading, 25 to 30 mmHg higher than
that measured at home. Home measurement
reduces the effects of outside influences on blood
pressure readings, supplements the doctor’s
readings and provides a more accurate, complete
blood pressure history.
Grade 3 hypertension (severe)
110
Grade 2 hypertension (moderate)
105
100
95
90
85
80
WHO Blood Pressure Classification
Standards to assess high blood pressure, without
regard to age, have been established by the World
Health Organization (WHO), as shown in the chart below.
23
Grade 1 hypertension (mild)
High-normal
Normal
Optimal
120
130
140
150
160
Systolic blood pressure
170
180
mmHg
TROUBLESHOOTING
Batteries are drained
Replace all batteries with new ones
Battery polarities are not in
the correct position
Re-install the batteries with their
negative and positive ends matching
their indicated in the battery
compartment
Loose in plug or contact with
outlet (IF AC adaptor is used)
Check the wiring to make sure plug
& outlet are properly secured
The cuff position is not correct
Sit comfortably and still. Ensure that
the cuff is at the same level as the
heart
ERROR code 2
(E2)
appears
You moved your arm or body
during measurement
Make sure you remain very still and
quiet during the measurement
ERROR code 3
(E3)
appears
The cuff position is not
fastened properly
Fasten the cuff correctly
Nothing appears in
the display, even
when the power is
turned on
ERROR code 1
(E1)
appears
24
TROUBLESHOOTING
ERROR code 3
(E3)
appears
The cuff may not be applied
Check whether tube connection of
the cuff is secured to the unit
properly
ERROR code 4
(E4)
appears
The unit does not measure
If you have a very weak or irregular
heart beat, the device may have
difficultly in determining your blood
pressure
There is a measuring Error
Sit comfortably and still. Fasten the
cuff again carefully
ERROR code 5
(E5)
appears
Cuff over inflated
The measurement range is over
300 mmHg. It is recommended to
see the doctor as soon as possible.
ERROR code 6
(E6)
appears
Low battery
The battery power is too low to
function. Replace the batteries with
new ones.
The monitor keeps
inflating
Circuit locked
Remove and reinsert the batteries
and then proceed to take
measurement again.
25
TECHNICAL SPECIFICATION
Display
Measurement Range
Accuracy
Resolution
Measurement Method
Power Source
Optional AC Adaptor
Operating Temperature / Humidity
Storage Temperature / Humidity
Operation, storage and
transport atmospheric pressure
Outer Dimensions
Arm Circumference
Accessories
Classification
Key to symbols
: LCD Display
: Systolic Pressure: 50-250 mmHg ; Diastolic Pressure: 30-200 mmHg
Pulse : 40-180 beats/minute
: Pressure : +/-3 mmHg
Pulse : +/-5% of reading
: Pressure : 1 mmHg
Pulse : 1 beat / minute
: Non-invasive, Oscillometric method
: 4 x 1.5V AAA batteries (battery life 300 times)
: Input 100-240V, 50-60 Hz ; Output 6V@600mA (service life 5000 times)
: +5˚C to +40˚C, 15-93% RH maximum
: -25˚C to +70˚C, up to 93% RH maximum
: 700hPa to 1060hPa
: Approx. 164 x 99 x 46mm
: 22-36cm (Original), 17-22cm (Optional), 35-44cm (Optional), 22-44cm (Optional)
: Cuff, User Manual, Storage Pouch, Batteries(Optional), AC Adaptor(Optional)
: Application part Type BF
: Application part Type BF
: Class II equipment symbol
26
SYMBOLS
Function / Meaning
Symbols
SN
Serial Number
Manufacturer
Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks.
SYS
Systolic Blood Pressure in mmHg
DIA
Diastolic Blood Pressure in mmHg
PUL
Pulse
EC Directive Medical Device Label
Caution
Authorized Representative in the European Community
WEEE Label
Refer to instruction manual / booklet
Keep dry
NOTICE:
• Operation mode : Continuous
•
Attention, Consult ACCOMPANYING DOCUMENTS.
27
Appendix I
The Sphygmomanometer (MD41W0/MD41W1) is intended for use in the electromagnetic environment
specified below. The customer or the user of the Sphygmomanometer (MD41W0/MD41W1) should assure
that it is used in such an environment.
Conducted and
radiated RF
EMISSIONS
Compliance
Electromagnetic environment - guidance
The Sphygmomanometer (MD41W0/MD41W1) uses
RF energy only for its internal function. Therefore, its
RF emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
The Sphygmomanometer (MD41W0/MD41W1) is
suitable for use in all establishments, including
domestic establishments and those directly connected
to the public low-voltage power supply network that
supplies buildings used for domestic purposes.
The Sphygmomanometer (MD41W0/MD41W1) is intended for use in the electromagnetic environment
specified below. The customer of the user of Sphygmomanometer (MD41W0/MD41W1) should assure that it
is used in such an environment.
Electrostatic discharge
IEC 61000-4-2
Rated power frequency
magnetic fields
IEC 61000-4-8
± 8 kV contact
± 15 kV air
50 Hz: 30 A/m
60 Hz: 30 A/m
± 8 kV contact
± 15 kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered
with synthetic material, the relative
humidity should be at least 30 %.
50 Hz: 30 A/m
60 Hz: 30 A/m
Power frequency magnetic fields
should be at levels characteristic of
a typical location in a typical
commercial or hospital
environment.
Appendix II
The Sphygmomanometer (MD41W0/MD41W1) is intended for use in the electromagnetic environment
specified below. The customer of the user of Sphygmomanometer (MD41W0/MD41W1) should assure that it
is used in such an environment.
Immunity test
Conducted
disturbances
induced by RF
fields
IEC 61000-4-6
Radiated RF EM
fields
IEC 61000-4-3
IEC 60601
test level
Compliance level
3 Vrms
0.15 MHz - 80 MHz
3 Vrms
0.15 MHz - 80 MHz
6 Vrmsa in ISM and
amateur radio
bands between
0,15 bMHz and 80
MHz
6 Vrmsa in ISM and
amateur radio
bands between
0,15 bMHz and 80
MHz
80% AM at 1 kHz
80% AM at 1 kHz
10 V/m
10 V/m
80 MHz - 2.7 GHz
80 MHz - 2.7 GHz
80% AM at 1 kHz
80% AM at 1 kHz
Electromagnetic environment - guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the
Sphygmomanometer (MD41W0/MD41W1), including
cables, than the recommended separation distance
calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
where P is the maximum output power rating of the
transmitter in Watts (W), d is the minimum
recommended separation distance in meters (m), and
E is the immunity test level in V/m.
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey, a
should be less than the compliance level in each
frequency range.
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
r.m.s., before modulation is applied.
The ISM (industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are 6,765 MHz to 6,795
MHz; 13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 MHz to 40,70 MHz. The amateur
radio bands between 0,15 MHz and 80 MHz are 1,8 MHz to 2,0 MHz, 3,5 MHz to 4,0 MHz, 5,3 MHz to 5,4
MHz, 7 MHz to 7,3 MHz, 10,1 MHz to 10,15 MHz, 14 MHz to 14,2 MHz, 18,07 MHz to 18,17 MHz, 21,0 MHz
to 21,4 MHz to 24,99 MHz, 28,0 MHz to 29,7 MHz and 50,0 MHz to 54,0 MHz.
Before modulation is applied.
Appendix III
Recommended separation distances between
portable and mobile RF communications equipment and the Sphygmomanometer
(MD41W0/MD41W1)
The Sphygmomanometer (MD41W0/MD41W1) is intended for use in an electromagnetic environment in which radiated
RF disturbances are controlled. The customer or the user of the Sphygmomanometer (MD41W0/MD41W1) can help
prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and the Sphygmomanometer (MD41W0/MD41W1) as recommended below,
according to the maximum output power of the communications equipment.
Rated maximum output power of
transmitter (W)
Separation distance according to frequency of transmitter (m)
3 Vrms
10 V/m
0.01
0.200
0.060
0.1
0.632
0.190
2.000
0.600
10
6.33
1.90
100
20.0
6.00
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m)
can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power
rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
Appendix IV
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced technician for help.
WARNING
• To comply with the limits of the Class B digital device, pursuant to Part 15 of the FCC Rules, this device is
comply with Class B limits. All peripherals must be shielded and grounded. Operation with non-certified
peripherals or non-shielded cables may results in interference to radio or reception.
• Any changes or modifications not expressly approved by the grantee of this device could void the user's
authority to operate the device.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that my cause undesired operation.
Symbol for the marking of electrical and electronics devices according to
Directive 2002/96/EC.
The device, accessories and the packaging have to be disposed of waste
correctly at the end of the usage. Please follow Local Ordinances or
Regulations for disposal.
Grandway Technology (Shenzhen) Limited,
Block 7, Zhu Keng Industrial Zone,
Ping Shan District, 518118 Shenzhen,
PEOPLE’S REPUBLIC OF CHINA
Shanghai International Trading Corp. GmbH (Hamburg)
Eiffestrasse 80, 20537 Hamburg, Germany.
0123
P/N: 83-M41W0-SEN00A-R
MADE IN CHINA
#1017

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42
Creator Tool                    : Adobe Illustrator CC 2017 (Macintosh)
Create Date                     : 2017:10:11 11:57:40+08:00
Modify Date                     : 2017:10:11 11:57:40+08:00
Metadata Date                   : 2017:10:11 11:57:40+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 8
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 1694 bytes, use -b option to extract)
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : True
Max Page Size W                 : 143.000730
Max Page Size H                 : 103.999841
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, Arial-ItalicMT, Arial-BoldMT, Arial-BoldItalicMT, Arial-Black, Helvetica, CenturyGothic, MyriadPro-Regular
Font Family                     : Arial, Arial, Arial, Arial, Arial Black, Helvetica, Century Gothic, Myriad Pro
Font Face                       : Regular, Italic, Bold, Bold Italic, Regular, Regular, Regular, Regular
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, TrueType, TrueType, Open Type
Font Version                    : Version 5.01.2x, Version 5.00.2x, Version 5.01.2x, Version 5.00.2x, Version 5.00.1x, 12.0d1e3, Version 2.35, OTF 1.006;PS 001.000;Core 1.0.23;hotunix 1.28
Font Composite                  : False, False, False, False, False, False, False, False
Font File Name                  : Arial.ttf, Arial Italic.ttf, Arial Bold.ttf, Arial Bold Italic.ttf, Arial Black.ttf, Helvetica.dfont, Century Gothic, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : White, Black, 0c 0m 0y 30k, 0c 0m 0y 20k, 0c 0m 0y 30k-1, 0c 0m 0y 40k, 0c 0m 0y 50k, 0c 0m 0y 60k, 0c 0m 0y 70k, 0c 0m 0y 70k-1, White, 0c 0m 0y 100k, New Color Swatch 6, 0c 0m 0y 65k, PANTONE 877 C, PANTONE 368 C, PANTONE 151 C, 0c 100m 100y 40k, 0c 100m 100y 0k, 0c 40m 100y 0k, 10c 0m 100y 0k, 100c 0m 100y 10k, 50c 0m 100y 0k, PANTONE 7481 C, PANTONE 129 C, PANTONE 1505 C, PANTONE 185 C
Swatch Colorant Type            : PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, SPOT, SPOT, SPOT, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, SPOT, SPOT, SPOT, SPOT
Swatch Colorant Tint            : 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000
Swatch Colorant Mode            : CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, RGB, RGB, RGB, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK
Swatch Colorant Cyan            : 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 9.999200, 100.000000, 50.000799, 60.000002, 0.000000, 0.000000, 0.000000
Swatch Colorant Magenta         : 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 40.000001, 0.000000, 0.000000, 0.000000, 0.000000, 16.000000, 41.999999, 91.000003
Swatch Colorant Yellow          : 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 55.000001, 76.999998, 76.999998, 75.999999
Swatch Colorant Black           : 0.000000, 100.000000, 29.999200, 20.000000, 29.999200, 40.000001, 50.000799, 60.000002, 70.000798, 70.000798, 0.000000, 100.000000, 100.000000, 65.000403, 40.000001, 0.000000, 0.000000, 0.000000, 9.999200, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000
Swatch Colorant Red             : 142, 96, 242
Swatch Colorant Green           : 142, 191, 124
Swatch Colorant Blue            : 140, 26, 0
Format                          : application/pdf
Title                           : MD41W0-N3b-Manual
Rendition Class                 : proof:pdf
Document ID                     : xmp.did:fe9c45b1-aa47-4e21-90cb-7e3cb34727e6
Instance ID                     : uuid:b6ccd9f4-d950-4043-b3a1-65a5ada27166
Original Document ID            : uuid:7de9bbbb-1b55-0343-bc90-836bb9b8cd3d
Version ID                      : 1
Derived From Instance ID        : uuid:8568d342-9a9e-4341-a4d5-cd25214659b5
Derived From Document ID        : uuid:7de9bbbb-1b55-0343-bc90-836bb9b8cd3d
Derived From Original Document ID: uuid:7de9bbbb-1b55-0343-bc90-836bb9b8cd3d
Derived From Rendition Class    : proof:pdf
History Action                  : saved
History Instance ID             : xmp.iid:fe9c45b1-aa47-4e21-90cb-7e3cb34727e6
History When                    : 2017:10:11 11:57:35+08:00
History Software Agent          : Adobe Illustrator CC 2017 (Macintosh)
History Changed                 : /
Producer                        : Adobe PDF library 15.00
Trapped                         : False
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
Page Count                      : 35
Creator                         : Adobe Illustrator CC 2017 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ABAFMD41WX

Navigation menu