Centrifugal Ceiling and Cabinet
Exhaust Fans
Models SP and CSP

Making a Sound Difference
with Silent Solutions

November

2006

Ceiling and Cabinet Exhaust Fans
Great things come in small packages, as do our ceiling fans (Model SP) and cabinet fans (Model CSP). Be
assured when you buy any Greenheck product, you are getting a quality product at a competitive price. In
fact, we guarantee our ceiling and cabinet exhaust fans with a three (3) year warranty. We offer the most
comprehensive ceiling and cabinet exhaust fan line in the commercial market. We are your market leader!

Benefits
Benefits
•

Low sound

•

Compact size

•

Competitive price

•

Broadest performance selections in the industry

Go Inside the Numbers
•

Greenheck has been providing solutions for over 50 years.

•

Preferred 3 to 1 over the competition.

•

Number 1 in product quality and reliability.

•

Number 1 in customer satisfaction and after-sale customer
service support.

•

More than 400 times a day a new ceiling
fan is put into service.

•

3 year warranty.

Greenheck Fan Corporation certifies that
the SP models shown herein are licensed to
bear the AMCA seal. The ratings shown are
based on tests and procedures performed in
accordance with AMCA Publication 211 and
AMCA Publication 311 and comply with the
requirements of the AMCA Certified Ratings
Program.

Greenheck Fan Corporation certifies that the
CSP models shown herein are licensed to
bear the AMCA seal. The ratings shown are
based on tests and procedures performed in
accordance with AMCA Publication 211 and
comply with the requirements of the AMCA
Certified Ratings Program.

SP fans
fans are designed for ceiling
SP
mounted applications.

CSP fans are designed for inline
remote mounted applications.

Models SP and CSP are listed electric fans
(UL/cUL 507). Ceiling Exhaust Fans are also
UL Listed for above bathtub/shower with GFCI
branch protected circuit. File no. E33599.

Leading Edge Technical Support
When you need extensive product and IOM (Installation, Operation and
Maintenance Manual) information, our products are supported by the
industry’s best product literature, electronic media, and Computer Aided
Product Selection (CAPS) program. You’ll also find this information on our
website at www.greenheck.com
You can always count on personal service and expertise from our national and
international representative organization. To locate your nearest Greenheck
representative, call 715-359-6171 or visit our website at

2

Model Number Code

®

SP - A 50 FL
Light Options:
L - Fan/Light (Incandescent) Combination
FL - Fan/Light (Fluorescent) Combination
Nominal cfm at 0.10 inches static pressure

Level of Construction:
A - Premium unit; lowest sound, insulated housing
B - Deluxe unit; low sound, low profile
C - Standard unit; lowest profile, inexpensive
Model:
SP - Silent Partner
CSP - Cabinet Silent Partner

Table of Contents
SP-A . . . . . . . . . . . . . . . . . . . . . . . . 4
SP-A Light . . . . . . . . . . . . . . . . . 5
SP-A Performance . . . . . . .16

CSP-A . . . . . . . . . . . . . . . . . . . . .10
CSP-A Performance . . . . .18

SP-B . . . . . . . . . . . . . . . . . . . . . . . . 6
SP-B Light . . . . . . . . . . . . . . . . . 7
SP-B Performance . . . . . . .17

CSP-B . . . . . . . . . . . . . . . . . . . . .11
CSP-B Performance . . . . .19

SP-C . . . . . . . . . . . . . . . . . . . . . . . . 8
SP-C Performance. . . . . . .17

Sound Data . . . . . . . . . . . . . . . . 9
Accessories . . . . . . . . . 12 - 15
Specifications . . . . . . . . . . . .19

Quick Delivery and Quick Build Programs
Order from hundreds of SP and CSP configurations, accessories, and
thousands of other products that can ship to your job site in less than 24
hours. We have strategically located warehouses across the United States and
internationally to fill your request at a moments notice. Speed up your process
even more by ordering your units at QD Online at www.greenheck.com/qd
www.greenheck.com/qd.
For other sizes and configurations where rapid response time is required, our
Quick Build (QB) Program manufactures and ships your custom products in
one, three, five, or ten days.

3

SP

®

PREMIUM CEILING FAN

A

The SP-A is a Premium Ceiling Fan. It is in the top of its class when it comes to meeting sound
requirements.
• Profile as low as 101/2 inches.
• Sound levels as low as 0.7 sones.

2

5

• Air volume as high as 1,607 cfm.

7

• UL Listed for above bathtub/
shower with GFCI branch protected
circuit.

8
1

4

6

SP-A
SP-A FEATURES
1

Spring Loaded Aluminum Backdraft
Damper - Eliminates rattling or
unwanted backdrafts.

2

Outlet - Both square and round outlets
are field rotatable from horizontal to
vertical discharge.

3

11
12

3

10

Power Assembly - Removes quickly for
maintenance or conversion from horizontal to
vertical discharge.

4

External Electrical Access - Eliminates removing
motor pack, saving installation time.

5

Electrical Knockouts (horizontal or vertical) Eliminates drilling holes.

9

Grille Options
Designer - Standard Grille
Decorative - Lighted and non-lighted
Aluminum - White enamel finish
Stainless Steel - Polished stainless steel finish

Round Duct Connection
Standard - Sizes A50, A70,
and A90.

6

Acoustic Insulation - Absorbs sound.

7

Disconnect - Servicing is quick and safe.

8

Electrical Junction Box - Large for easy wiring.

Exclusive Electrical Wiring Feature

9

Attractive Designer Grille - Concealed
attachment screws securely fasten grille to
housing for quiet, rattle free operation.

Greenheck SP-A models are the only fans of this type
with an electrical access cover located on the housing
exterior. This feature permits external wiring without
removing the power assembly, saving installation time
and cost.

10

Mounting Brackets - Fully adjustable for multiple
installation conditions.

11

Housing - Embossed galvanized steel for rigidity.

12

Motors - All motors are compatible for use
with speed controls and have thermal overload
protection. Both domestic and international
applications available.
•
•

4

Round Duct Adapter
Optional - Sizes A110 through A510

Vertical
Vertical Discharge
Discharge
Photo shows exhaust outlet
duct installed in the optional
vertical position. The power
assembly must be rotated
to match the duct adapter
position. (See SP-A IOM)

50 cycle, 220v, and 240v options.

Double
Double Wide
Wide Fans
Fans

(See page 16 for availability)

Available for applications
requiring 700 cfm or greater.
Double wide fans have two
double width forward curved
wheels, which are housed in
separate scrolls, and driven by
a single motor.

60 cycle, 115v, 208v, 220v, 230v, and 277v
options. (See CAPS for availability)

SP

®

PREMIUM CEILING FAN

A

Light Options
Greenheck’s fan/light combination includes a prismatic or frosted lens,
and compact fluorescent or incandescent lamps. Our unique patent
pending light box is manufactured with a reflective material to increase
the light given off by either type of lamp. UL Listed for above bathtub/
showers with GFCI branch protected circuit.

Available on Sizes 50 - 125
Prismatic Lens

Frosted Lens

The prismatic lens design provides
approximately 25% more light than a
traditional frosted lens. The lens may
be easily removed to replace light
bulbs. (Patent Pending)

Compact Fluorescent Lamps (CFL)
•
•
•
•
•

The frosted lens option is a
traditional design which lets
approximately 80% of light
through the lens. The lens may
be easily removed to replace light
bulbs.

Incandescent Lamps

Quick start bulbs
Reflective light box (Patent Pending)
Produce 90% less heat
Lower energy costs
Two 13 watt CFL bulbs equals 100
watts of incandescent light (included)

A major advantage of using CFL’s is to
save money, as shown in the table to the
right. This table assumes the light is on for
six hours per day and that the electric rate
is 10 cents per kilowatt-hour. This study
was based over a 4½ year period.

•
•
•
•

Dimmable
Reflective light box (Patent Pending)
Low first-cost light
One bulb provides up to 100
watts of light (by others)

27 Watt Compact
Fluorescent
Cost of Lamps

100 Watt
Incandescent

$14.00

$0.50

1,642.5 days (4.5 years)

167 days

$5.91

$21.90

0

10

Total Cost

$40.60

$103.55

Savings Over Lamp Life

$62.95

$0.00

Lamp Life
Annual Energy Cost
Lamps Replaced in 4.5 years

Source: U.S. Department of Energy, August 2001
Office of Energy Efficiency and Renewable Energy

Ceiling Radiation Damper
SP-A Fan

National Fire Protection Association (NFPA)
Standard 90A requires openings in fire rated
ceiling/floor assemblies be protected by
appropriately rated ceiling radiation dampers.
As a result, many local codes require fans
installed in fire rated ceilings must also be
protected by dampers which are insulated
against both heat and flame.

Hanging
Vibration
Isolation
Ceiling
Radiation
Damper
Fire Rated
Ceiling

3"

AxB

Grille

*CRD is approximately 1/4 inch larger
than housing dimension. (See SP-A IOM)

The Greenheck SP-A ceiling radiation damper is UL Classified, rated at three
to four hours fire resistance, and is available on all SP-A fans and fan/light
combinations. This design saves space by allowing the damper to mount
5
directly beneath the fan.

SP

®

DELUXE CEILING FAN
The SP-B is a Deluxe Ceiling Fan compact enough for almost
any application. If quiet is what you are after, this fan will
accommodate your needs.
•

Profile as low as 6 15/16 inches.

•

Sound levels as low as 1.7 sones.

•

Air volume as high as 197 cfm.

•

UL Listed for above bathtub/shower with
GFCI branch protected circuit.

B

9
1
2
3
10

7

SP-B
SP-B FEATURES
1

Aluminum Backdraft Damper Prevents unwanted backdrafts.

2

Round Standard Outlet (4 or 6 in.) - Versatile
for quick, easy connections.

3

Power Assembly - Removes quickly for
maintenance.

4

Electrical Access (vertical) - Eliminates drilling
holes.

5

Disconnect - Servicing is quick and safe.

6

Electrical Junction Box - Large for easy wiring.

7

Attractive Designer Grille - Concealed
attachment screws securely fasten grille to
housing for quiet, rattle free operation.

8

Mounting Brackets - Fully adjustable for multiple
installation types.

9

Housing - Embossed galvanized steel for rigidity
and low profile for height restricted areas.

10

Motors - All motors are compatible for use
with speed controls and have thermal overload
protection. Both domestic and international
applications available.
•

50 cycle, 220v, and 240v options.
(See page 17 for availability)

•

60 cycle, 115v, 208v, 220v, 230v, and 277v
options. (See CAPS for availability)

8

6

5

4

Grille Options
Designer - Standard Grille
Decorative - Lighted and non-lighted
Aluminum - White enamel finish
Stainless Steel - Polished stainless steel finish

Round Duct Connection
4 in. - B50, B70, and B80
6 in. - B90, B110, B150, and B200

Contractor 4 Paks
Save installation time and labor
by installing the housing first, then
installing the internal components
after the sheetrocking, plastering, and
finishing is done.
Housings are packaged in one box,
power assembly and grille are
packaged in another box.
Components are shipped to coincide
with the phase of your project.

6

SP

®

DELUXE CEILING FAN

B

Light
Light Options
Options
Greenheck’s new fan/light combination includes a prismatic or frosted
lens, and compact fluorescent or incandescent lamps. Our unique patent
pending light box is manufactured with a reflective material to increase
the light given off by either lamp. UL Listed for above bathtub/showers
with GFCI branch protected circuit.

Available
Available on
on Sizes
Sizes 50
50 -- 150
150
Prismatic Lens

Frosted Lens

The prismatic lens design provides
approximately 25% more light than a
traditional frosted lens. The lens may
be easily removed to replace light
bulbs. (Patent Pending)

Compact Fluorescent Lamps (CFL)
•
•
•
•
•

The frosted lens option is a
traditional design which lets
approximately 80% of light
through the lens. The lens may
be easily removed to replace light
bulbs.

Incandescent Lamps

Quick start bulbs
Reflective light box (Patent Pending)
Produce 90% less heat
Lower energy costs
Two 13 watt CFL bulbs equals 100
watts of incandescent light (included)

•
•
•
•

Dimmable
Reflective light box (Patent Pending)
Low first-cost light
One bulb provides up to 100
watts of light (by others)

27 Watt Compact
Fluorescent

A major advantage of using CFL’s is to
save money, as shown in the table to the
right. This table assumes the light is on
for six hours per day and that the electric
rate is 10 cents per kilowatt-hour. This
study was based over a 4½ year period.

Cost of Lamps

100 Watt
Incandescent

$14.00

$0.50

1,642.5 days (4.5 years)

167 days

$5.91

$21.90

0

10

Total Cost

$40.60

$103.55

Savings Over Lamp Life

$62.95

$0.00

Lamp Life
Annual Energy Cost
Lamps Replaced in 4.5 years

Source: U.S. Department of Energy, August 2001
Office of Energy Efficiency and Renewable Energy

Ceiling Radiation Damper
SP-B Fan

National Fire Protection Association (NFPA)
Standard 90A requires openings in fire rated
ceiling/floor assemblies be protected by
appropriately rated ceiling radiation dampers.
As a result, many local codes require fans
installed in fire rated ceilings must also be
protected by dampers which are insulated
*CRD is approximately 1/4 inch larger
against both heat and flame.
than housing dimension. (See SP-B IOM)
The Greenheck SP-B ceiling radiation damper
is UL Classified, rated at three to four hours fire resistance, and is available on
all SP-B fans and fan/light combinations. This design saves space by allowing
the damper to mount directly beneath the fan.
Hanging
Vibration
Isolation

Ceiling
Radiation
Damper

Fire Rated
Ceiling

3"

AxB

Grille

7

SP

®

STANDARD CEILING FAN
The SP-C is our economy ceiling fan designed
for light commercial applications.
•

Profile as low as 3 5/8 inches.

•

Sound levels as low as 2.9 sones.

•

Air volume as high as 52 cfm.

•

UL Listed for above bathtub/shower with
GFCI branch protected circuit.

1

2
7
6

3

4

8

SP-C FEATURES
1

Plastic Backdraft Damper - Prevents unwanted
backdrafts.

2

Round Outlet - 3 inch diameter allows quick easy
connections.

3

Power Assembly - Removes quickly for
maintenance.

4

Disconnect - Servicing is quick and safe.

5

Polymeric Grille - Quickly snaps into place.

6

Mounting Brackets - Adjustable for several
installation types.

7

Housing - Galvanized steel for rigidity and low
profile for height restricted areas.

8

Motors - Compatible for use with speed controls
and has thermal overload protection.
•

8

60 cycle, 115v

C

5

Things to know,
when sound is critical
Sound Data
The sound data shown in this catalog has been
presented to aid the system designer in selecting a
fan which will meet the desired sound criteria. Sone
levels have been included on the performance pages
to provide a means of quickly evaluating the relative
loudness of a fan selection.
What is a sone?
Sones are an internationally recognized unit of loudness. In
practical terms, the loudness of one sone is equivalent to the
sound of a quiet refrigerator measured from five feet away
in an acoustically average room. A sone is a single number
rating, which indicates the inlet noise derived from the eight
audible octave bands. Sones are a linear measurement of
sound level. For example, a sound level of 10 sones is twice
as loud as 5 sones.

®

SUGGESTED LIMITS FOR ROOM LOUDNESS
Sones
1.3-4
1.7-5
2-6

DBA
32-48
36-51
38-54

2.5-8

41-58

3-9

44-60

4-2

48-64

5-15

51-67

7-21

56-72

Private homes (rural and suburban)
Conference rooms
Hotel rooms, libraries, movie
theatres, executive offices
Schools and classrooms, hospital
wards and operating rooms
Court rooms, museums, apartment
houses, private homes (urban)
Restaurants, lobbies, general open
offices, banks
Corridors and halls, cocktail
lounges, washrooms and toilets
Hotel kitchens and laundries,
supermarkets

Reprinted from AMCA Publication 302 (Application of Sone
Ratings for Non Ducted Air Moving Devices, with room—sone—
dBA correlations) with the written permission from the AMCA
International, Inc., 30 West University Drive, Arlington Heights, IL
60004-1893.
NOTE: Values above are for room loudness and are not sound
ratings. Room loudness is the resulting level in a conditioned space
after the acoustical qualities of the room have been accounted for.

What is the difference in a AMCA Sone vs. HVI Sones?
In general, the AMCA (Air Movement and Control Association)
sone value is focused on commercial markets, whereas the
HVI (Home Ventilating Institute) sone value is focused on residential markets. Both calculate their sone data from
the same raw test data (eight octave bands), however an AMCA sone applies a hemispherical correction factor
to the sound power and rounds to the nearest 0.1, whereas HVI applies a spherical correction factor to the sound
power and rounds to the nearest 0.1 under 1.5 sones and to the nearest 0.5, 1.5 sones and greater. There are no
conversions from one sone to the other, each must be calculated. In every instance the same fan will have a lower
HVI calculated sone rating than an AMCA calculated sone rating.

Can radiated noise increase the sound levels?
Radiated noise from fan housings can cause unacceptable sound levels, on any brand of fan. The size of these
fans allows them to be placed in areas where this noise will be transmitted to the conditioned space through walls
or ceilings. Where possible, cabinet fans should be located in remote parts of the ventilation system.
When should a SP or CSP fan be used?
Model SP and CSP fans are designed for the lowest possible sound levels. Forward curved wheels, insulated
housings, and vibration isolators between the motor and housing contribute to quiet, efficient operation.
Applied and installed as recommended, SP and CSP sound levels will fall well within the ranges shown in
the chart above. For applications where sound levels are critical, a remote mounted CSP with ductboard is
recommended. Placement of SP/CSP fans should take into account the desired sound level at the location of
the listener. Their compact size allows the system
designer greater flexibility in locating these fans for
lowest sound levels. In critical sound areas, insulated
Fiberglass
ductwork, flexible duct connections, or placing the
fan in a remote section of the ductwork (away from
Remote mounted
the critical area) offers the best means of meeting
Model CSP with
vibration isolators and
desired sound levels.
insulated ductwork
provides quietest
When room sound levels are critical, such as in
installation.
executive offices, conference rooms, hospital
operating rooms, and school study areas, a CSP
fan is the best choice. Shown here is a comparison
of SP and CSP fans of the same size, with equal
performance in typical installations. The CSP shows
lower sone values.
Model
CFM
SP-A410 405
CSP-A410 426

WG
1/8
1/8

FRPM
1000
1000

*Sone value with insulated inlet duct.

Sones
3.7
2.1*

Model SP mounted directly
overhead may be too loud for
sound critical applications.

9

CSP

®

PREMIUM INLINE FAN

A

The CSP-A is a Premium Inline Fan. It outperforms the competition and is preferred by specifying
engineers.
•
•
•
•

Profile as low as 10 1/2 inches.
Sound levels as low as 0.8 sones.
Air volume as high as 3,778 cfm.
UL/cUL Listed.

6

2

8

5

CSP-A FEATURES
1

2

3

Power Assembly - Removes quickly for
maintenance or conversion from horizontal
to vertical discharge.
External Electrical Access - Eliminates
removing motor pack, saving installation time.

5

Electrical Knockouts (horizontal or vertical) Eliminates drilling holes.

6

Acoustic Insulation - Absorbs sound.

7

Disconnect - Servicing is quick and safe.

8

Electrical Junction Box - Large for easy wiring.

9

Access Panel - Gain easy access to internal
components once installed.

12
3
11
10

Mounting Brackets - Fully adjustable for multiple
installation conditions.

11

Housing - Embossed galvanized steel for rigidity.

12

Motors - All motors are compatible for use
with speed controls and have thermal overload
protection. Both domestic and international
applications available (not shown).
•

50 cycle, 220v, and 240v options.
(See page 18 for availability)

•

10

60 cycle, 115v, 208v, 220v, 230v, and 277v
options. (See CAPS for availability)

4
1

Outlet - Both square and round outlets
are field rotatable from horizontal to
vertical discharge.

4

10

7

Spring Loaded Aluminum Backdraft
Damper - Eliminates rattling or unwanted
backdrafts.

9

Exclusive Electrical Wiring Feature
Greenheck CSP-A models are the only fans of this type
with an electrical access cover located on the housing
exterior. This feature permits external wiring without
removing the power assembly, saving installation time
and cost.

Vertical Discharge
Discharge
Vertical
Photo shows exhaust outlet
duct installed in the optional
vertical position. The power
assembly must be rotated
to match the duct adapter
position. (See CSP-A IOM)

Double Wide
Wide Fans
Fans
Double
Available for applications
requiring 700 cfm or
greater. Double wide
fans have two double
width forward curved
wheels, which are housed
in separate scrolls, and
driven by a single motor.

CSP

®

DELUXE INLINE FAN

B

The CSP-B is a compact Deluxe Inline Fan. It is designed to fit in small remote quarters.
•

Profiles as low as 6 15/16 inches.

•

Sound levels as low as 2.0 sones.

•

Air volume as high as 186 cfm.

•

UL/cUL Listed.

CSP-B FEATURES
1
2

2
1

5

4

9

Aluminum Backdraft Damper Prevents unwanted backdrafts.
Round Standard Outlet (4 or 6 in.) Versatile for quick, easy connections.

3
6

3 Power Assembly - Removes quickly for
maintenance.
4

10
8
7

Electrical Access (vertical) - Eliminates drilling holes.

5 Disconnect - Servicing is quick and safe.
6

Electrical Junction Box - Large for easy wiring.

7

Access Panel - Gain easy access to internal
components once installed.

8

Mounting Brackets - Fully adjustable for multiple
installation types.

9

Housing - Embossed galvanized steel for rigidity and
low profile for height restricted areas.

10 Motors - All motors are compatible for use with speed
controls and have thermal overload protection. Both
domestic and international applications available.
•

50 cycle, 220v and 240v options.
(See page 19 availability)

•

60 cycle, 115v, 208v, 220v, 230v, and 277v options.
(See CAPS for availability)

11

Accessories
®

Speed Controls
Speed controls may be used on Model SP and CSP fans for manual adjustment of the fan’s performance (for final
system balancing) or to control the fan’s output in confined spaces, such as conference or meeting rooms. The
fan can be adjusted to 60% of design airflow with a speed control. This reduction in airflow and fan speed is also
accompanied by a reduction in noise level. Solid state speed controls are available for a range of applications up
to 15 amps. Speed controls can be used to operate more than one fan if the combined total amperage of the
fans does not exceed the control rating.
Model 5WSSC - For use w/ shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
• Rated for 115 - 127v, 5 Amp
• UL Listed
• Require a 2x4 handy box
Model 5W240 - For use w/ shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
• Rated for 220 - 240v, 5 Amp
• UL Listed
• Requires 2x4 handy box
Model 5W277 - For use w/ shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
• Rated for 277v, 5 Amp
• UL Listed
• Requires 2x4 handy box
Model 8WSSC - For use w/ shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
• Rated for 220 - 240v, 8 Amp
• UL Listed
• Requires 2x4 handy box

FULL VOLTAGE

SWITCHED FULL VOLTAGE

RED

Dotted line indicates
for use with 10W
switch only.

BLACK

H

WHITE

Model 10WSSC - For use w/ shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
• Rated for 115 - 127v, 10 Amp
• UL Listed
• Requires 4x4 handy box

SPEED CONTROL

VARIABLE
VOLTAGE

AUX
DEVICE

120 VAC

FAN

Model 15WSSC - For use w/ shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
• Rated for 115 - 127v, 15 Amp
• UL Listed
• Requires 4x4 handy box

N

Switches
Switches may be used on Models SP and CSP fans to enable manual control of your fan or fan/light
combination. There are several options to fit your application.
NEMA 1- Single pole rocker switch assembly.
• Rated for, 115v, 15 Amp, 1/2 Hp

• UL Listed

EXTERNAL JUMPER

Model MS-16- Single pole rocker switch assembly
with cover and pilot light.
• Rated for, 115v, 15 Amp, 1/2 Hp

• UL Listed

NEMA 1 - Two pole rocker switch assembly.

LOAD

LOAD

• Rated for, 220/230/240/277v, 20 Amp, 2 Hp • UL Listed
• Requires a 2x4 handy box.

Time Delay Switch
Time delay switches save energy by automatically turning off equipment. They may be used with Models SP
and CSP fans and fan/light combinations, for extended operating time of fan. Time delay switches act in the
same manner as a standard switch, however, there is a delay of 1 to 60 minutes after the it has been turned off.
Model GTD - Single switch controls both fan
and light. Available shipped loose.
• Silent Operation
• UL Listed

(500 Watt Max)
LIGHT
115 VOLT AC (HOT)
60 CYCLE

BLACK

• Rated for 115v
• Requires 2x4 handy box

(7.5 Amps Max)
FAN MOTOR
RED

(NEUTRAL)
WHITE

12

BLUE

Accessories
®

Motion Detectors
Motion detectors may be used with Models SP and CSP fans, or fan and light combinations. Motion detectors
use a passive infrared motion detector that will automatically turn on the fan when a change in temperature is
sensed. They have a viewing area of 180 degrees, however they must be placed in the line-of-sight. They also
have an adjustable time delay shutoff setting of 1 to 20 minutes.
Grille Motion Detectors
are available on models up
through size SP-A390 and
SP-B200.
• Rated for 115v
• UL Listed

Black
White
Red

Motion Sensor

Hot

Black

Hot

Green

Model MDW
For use on fan or lights.
Available shipped loose.
• Rated for 115v
• UL Listed
• Requires 2x4 handy box

Neutral

Gnd.
Red
Neutral

Fan Motor and/or
Light

Load
(12.5 Amps Max.)

Black
Green
White

Ground

Grille Mount

Wall Mount

Transformers
Transformers are available for applications requiring voltage reduction. Selection is based on motor amperage.
All transformers are shipped loose.
Model T-2.0 - UL Listed
• Rated for 230/277v to 115, 2 Amps

277 V SUPPLY

SWITCH BOX

Model T-4.3 - UL Listed
• Rated for 230/277v to 115, 4.3 Amps

BLK

BLK

BLK

H1

H2

H3

277V TO 115V TRANS.
750 VA

X1
RED

Model T-6.5 - UL Listed
• Rated for 230/277v to 115, 6.5 Amps

X2
RED

SWITCH

Model T-8.6 - UL Listed
• Rated for 230/277v to 115, 8.6 Amps

115 V MOTOR

Ceiling Radiation Dampers
The Greenheck SP-A and SP-B ceiling
radiation dampers are UL Classified, rated
at three to four hours fire resistance, and
is available on all SP-A and SP-B fans and
fan/light combinations. This design saves
space by allowing the damper to mount
directly beneath the fan.

SP Model CRD Length Width Height
A50 - A190
310
13 1/2
11 1/8
3
B50 - B200
320
14 3/8
12 1/4
3
A200 - A390
A410 - A510
350 18 7/16 14 15/16
3
A710 - A780
3/16
1
12 /4
3
A - 700
700 24
A900 - A1550 360 24 3/16 14 15/16
3
All dimensions shown in inches.
Add an “L” to all CRD models if fan & light combo is used.

Filters

Filter Model
SP Model
SP-A50 - A190
SP-B50 - B200, A200 - A390
SP-A410 - A510
SP-A710 - A780
SP-A900 - A155

F-200
F-200

*Metal
Grille
F-210
F-220

Filter
Area
(ft2)
.620
.785

NA

F-250

1.319

NA

F-260

1.797

Designer
Grill

All dimensions shown in inches. *Aluminium or Stainless Steel Grille.

Resistance in w.c.

Fans used in most applications, even where air is not excessively dirty, will collect airborne dirt on wheels and
motors over time. Accumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance.
Dirt buildup on the motor can cause it to overheat. All of these conditions will
FILTER LOSS CHART
shorten the life of the fan. To help reduce this accumulation, washable aluminum
.24
mesh filters are available to trap dirt before it enters the fan. These filters should
.22
be regularly cleaned to maintain performance. The Filter Loss Chart shows the
.20
effect the filter will have on performance. To determine the added resistance,
.18
divide the desired cfm by the filter area (ft2). This will give FPM. Use this with
.16
the filter loss chart to get the added resistance. In addition to reducing dirt
.14
accumulations on the motor and wheel, filters also reduce sound levels.
.12
.10
.08
.06
Mesh
Filter

.04
.02
SP
Grille

.00
0

1

2

3
4
5
6
7
Velocity FPM x 100

8

9

13

Wall Discharge Accessories
®

G

B
D

F
B

A C

E

E

C

A

D

E

Model WC (Round Connection)

Model WC (Square/Rectangular Connections)

Hooded Wall Cap

Hooded Wall Cap

• Aluminum construction - aluminum finish
• For outside wall applications
• Built in birdscreen (not available on WC-4) and damper

• Steel construction with black enamel finish
• For outside wall applications
• Built in birdscreen and damper

For use
Model
A
with sizes
WC-4 C50, B50-B80 61/2

B90-B200
A50-A190

WC-6
WC-8

8

A200-A510

11

B
6

C
4

D
23/4

E
5

8

6

41/8

5

8

51/8

3.5

11

For use
Model
A
B
C
D
E
F
with sizes
WC-10x3 50-290 51/2 123/4 31/2 101/4 111/8 41/4
WC-8x8 200-510 101/4 101/4 81/4 81/4 81/4 63/4
WC-18x8 700-1550 101/4 201/4 81/4 181/4 181/4 63/4

All dimensions shown in inches.

All dimensions shown in inches.
A

C

B
E
B

D
A

Model BVE

Model WL

Brick Vent

Wall Louvered Discharge

• Designed for installation in masonry walls
• Anodized aluminum construction
• Built in aluminum mesh insect screen

• Anodized aluminum grille
• Built in damper
• Not recommended for exterior applications exposed
to severe weather conditions. An external wall louver
is recommended for such applications.
Model
WL-10x3
WL-18x6

C

For use
with sizes

A
B
50-290
12
5 1/4
390-1550 19 3 /4
8

C
10
18

Model
BVE808
BVE128
BVE157

D
E
7 3 /4 3 1/2
9
6

For use
with sizes

A
50-290 8 1/8
390-510 12
700-1050 15 5/8

B
7 3/4
7 3/4
7 3/4

C
4
4
4

All dimensions shown in inches.

All dimensions shown in inches.

ACCESSORY PRESSURE DROPS

Model RDC
Round Duct Connector

Model
RDC-6
RDC-8

For use
with sizes

A110-A190
A200-A510

Dia.
6
8

Model TR 6x4
Transition Duct Reducer
• Reduces duct from 6 to 4
inches.
• Galvanized steel construction
Model

For use
with sizes

TR 6x4

B50-B200
A50-A90
A110-A190*

* Used in conjunction with RDC-6.

14

30

20
WL-18x6
RJ-10x10

10

CFM x 100

• Replaces the standard
square discharge ductAll dimensions shown in inches.
connector and damper
RDC-8
• Uses existing mounting holes
RDC-6
• Galvanized steel construction
• RDC-6 includes a damper
• RDC-8 does not include a
damper

The chart below can be used with all of the discharge
accessories shown on these two pages. Specific pressure
drop values for these accessories must be included in total
system calculations for proper fan selection.

BVE-157
WC-18x8

9
8
7

BVE-128
WC-8x8
WC-8

6

WC-10x3
WC-6
RJ-6x9
EL-10x3
WL-10x3
BVE-808
RFC-7
RCC-7

5
4

3

4 in.
dia
6 in.
dia.

2

1.01

6.25 in.

.02

.03

.04 .05 .06 .07 .08 .09.10

.2

.3

Pressure Drop in Inches of Water Gauge

Above accessories tested with 4 feet of inlet duct

.4

.5

.6

G
5
5
5

Roof Discharge Accessories
®

D

C

RJ-4 and
RJ-6x9

D

RJ-10x10

1
11 /8

C

91/4

31/2

E

10

A

E

B

Model RJ

B
A

Pitched Roof Cap
• Steel construction with black enamel finish
• Integral flashing flange
• Built in birdscreen and damper
For use
with sizes

Model
RJ-4

A
11

B
91/4

11 1
/

2

51 /8

Model EL - 10x3

C
81/4

D
5 5/16

Elbow Discharge with Grille

E
Throat
41/2 4 in. Dia.

C50, B50-B80
B90-B200
RJ-6x9
18 3/4 141/4 141/2 10 3/8 61/2
A50-A390
RJ-10x10 A410-A1050 181/2 27 1/2 15 3/4 235/8 91/2

•
•
•
•

6x9
10x10

Designed for installation under roof eaves
Painted steel louvered grille
Built in damper
For SP/CSP sizes 50-290

All dimensions shown in inches.

Flat Roof Caps
B
B

D

Dia.

B

B

C
D

11/2 in.

Dia.
A

A

C

D

Dia.
13/4 in.

C

C

D
Dia.
A

A

Model RCC-7

Model GRS

Model RFC-7

Model GRSF

Curb Cap

Curb Cap

Flashing Flange

Flashing Flange

• Weathertight aluminum
construction
• Integral birdscreen
• Built in curb cap
• Requires roof curb

• All aluminum exterior
construction
• Galvanized steel internal
supports
• Integral birdscreen
• Built in curb cap
• Requires roof curb

• Weathertight aluminum
construction
• Integral birdscreen
• Built in flashing flange

• All aluminum exterior
construction
• Galvanized steel internal
supports
• Integral birdscreen
• Built in flashing flange

RCC-7

50-390

15

12

10

63/8

Throat
Dia.
7

GRS-10

410-710

19

201/2

61/4

3

101/4

GRSF-10

410-710

23

201/2

61/4

3

101/4

GRS-12

780-1050

22

29

77/8

31/4

121/4

GRSF-12

780-1050

26

29

77/8

31/4

121/4

33/4

165/16

GRSF-16 1410-2150

30

29

83/4

33/4

165/16

41/4

205/16

GRSF-20

34

351/2

91/4

41/4

205/16

Model

For use
with sizes

A

B

C

D

GRS-16

1410-2150

26

29

83/4

GRS-20

3600

30

351/2

91/4

For use
with sizes

A

B

C

D

RFC-7

50-390

18

12

10

63/8

Throat
Dia.
7

Model

All dimensions shown in inches.

All dimensions shown in inches.

Hanging Vibration Isolators
Vibration isolator kits are available
for suspended installations. Kits
include all hardware necessary to
mount one unit, with the exception
of 10-32 threaded rod to be
supplied by others. Fan mounting
brackets include prepunched
mounting holes for ease of
installation.

3600

A

B

10-32 hanging
support rod by
others

Unit
Size
B50-B200
A50-A190
A200-A390
A410, A510
A710, A780
A700
A900-A1050
A1410-A1550
A1750, A2150
A3600

A

B

41/2
51/2
6 3/4

155/8
14 5/8
15 1/2

91/4

19 5/8

51/2

25 1/8

9 1/4

25 3/8

9 1/4
9 1/4

363/4
485/8

All dimensions shown in inches.

15

SP

®

PREMIUM CEILING FAN

A

Dimensional Data
C

D

E

Standard
Grille

131/4 10 5/8

115/8

6

DIA.

147/8 x 131/4

15 1/4 sq.

12

131/4

10 5/8

101/2

8

147/8

131/4

15 1/4 sq.

17

200, 250, 290, 390

14

117/8

111/4

8

8

147/8 x 131/4

15 1/4 sq.

24

410, 510

18

143/8

141/2

8

8

193/8 x 163/8

-

31

115/8 191/2 8

251/8 x 131/2

-

34

141/2

193/8 x 163/8

-

34

25 x 163/8

-

56

Model

A

50, 70, 90
110, 125, 190

B

235/8 115/8

700
710, 780

18

900, 1050, 1410, 1550

143/8

233/4 143/8

10

6

8

141/2 183/4 8

x

B

Decorative Unit
Grille
Wt.

Outlet connection width is 1 inch - Mounting bracket width is 1½ inch.
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

A
E

C
D

B

A
E

C

D

Performance Data
Model

RPM

Amps

Watts

HVI 1
Sones

2,3,5

SP-A50

700

0.31

18

0.7

850

0.27

20

0.8

900

0.34

29

1.0

950

0.58

49

0.8

1100

0.62

53

1.2

1400

1.30

113

2.0

900

0.43

48

2.0

1000

0.77

83

2.0

1050

0.72

81

2.5

1350

1.34

135

4.5

1000

1.74

121

3.0

1070

3.30

224

4.5

1100

3.20

350

5.5

1080

4.40

285

6.0

1600

3.30

348

8.5

950

4.00

285

4.5

1095

6.30

420

6.0

1450

7.40

786

9.5

1610

8.60

818

10.0

2,3,5

SP-A70
2,3,5

SP-A90
2,3,4,5,6

SP-A110
2,3,5,6

SP-A125
3,4,5,6

SP-A190
3,5

SP-A200
3,5

SP-A250
3,4,5

SP-A290
3,4,5

SP-A390
3

SP-A410

3,4

SP-A510

3

SP-A700
3

SP-A710
3,4

SP-A780

3

SP-A900
3,4

SP-A1050

3

SP-A1410
3,4

SP-A1550

1 HVI sones at 0.1 wg
2 Available with light

CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones

0.000
76
0.7
83
1.1
99
1.1
119
1.3
135
1.4
216
3.2
247
2.0
272
2.9
315
3.2
410
5.4
443
4.1
557
6.0
757
6.1
752
7.4
812
10.2
955
5.2
1125
7.2
1455
11.6
1607
12.4

0.100
51
1.0
70
1.1
88
1.4
110
1.2
123
1.7
197
2.8
225
2.3
251
3.0
293
3.3
395
5.4
413
3.8
512
5.7
729
6.1
714
7.2
782
10.2
907
5.7
1059
7.0
1414
11.6
1568
12.1

CFM/Static Pressure in inches of WG
0.125
0.250
0.375
0.500
0.625
47
30
1.1
1.8
66
42
1.4
2.2
84
61
25
1.4
1.7
1.9
106
88
1.2
1.6
121
104
1.8
1.9
192
167
133
2.9
3.1
3.4
220
196
172
142
105
2.4
3.0
3.5
4.1
4.6
246
227
210
185
157
3.0
3.4
4.4
4.6
4.9
287
257
231
207
175
3.3
3.6
3.9
4.1
4.5
391
368
345
325
307
5.4
5.7
6.0
6.3
6.4
405
351
305
3.7
3.7
4.3
501
439
392
325
5.6
5.5
5.4
4.7
723
700
679
649
613
6.1
6.3
6.7
7.1
7.3
701
653
588
485
320
7.2
7.0
6.8
6.7
6.7
775
741
704
665
625
10.2
9.9
9.5
9.5
9.4
896
841
773
701
5.8
6.1
6.2
6.2
1043
964
885
796
662
6.9
6.8
6.6
6.5
6.5
1404
1353
1307
1262
1218
11.7
11.6
11.5
11.6
11.6
1558
1506
1449
1407
1369
12.1
12.0
11.9
12.8
14.1

3 Available with CRD - Ceiling Radiation Damper
4 Available with 50 Hz motors (See CAPS for performance)

0.750

1.000

67
4.5
119
5.2
124
5.5
279
6.7

560
7.5

396
7.7

581
9.4

1174
11.6
1323
15.9

5 UL Listed for use above tubs.
6 Available with 277 volt motor.

Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.

16

SP

®

DELUXE CEILING FAN

B

Dimensional Data
Model

A

B

*C

50, 70, & 80

137/ 8

111/ 2

137/ 8 111/ 2

90, 110, 150, 200

Designer
Grille

D

E

615/ 16

4

3/ 4

715/ 16

6 11/ 4 147/8 x 131/4

147/8

x

131/4

Decorative
Grille
15

1/4

Unit
Wt.

sq.

9

15 1/4 sq.

10

B

A
E

D

C

*Add 1½ inches to C dimension for incandescent light.
Mounting bracket width is 1½ inch
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

Performance Data
Model

RPM AMPS Watts

HVI 1
Sones

2,3,5

SP-B50

625

0.50

38

1.4

675

0.53

45

1.4

900

0.60

54

2.5

700

0.65

50

2.0

SP-B110 950

1.14

80

1.5

1.70

129

2.5

2.20

173

4.0

2,3,5

SP-B70
2,3,5

SP-B80
2,3,4,5

SP-B90
2,3,4,5,6

2,3,4,5,6

SP-B150 1050
3,4,5,6

SP-B200 1100

1 HVI sones at 0.1 wg
2 Available with light

CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones

0.000
67
1.7
77
1.7
87
2.9
102
1.9
133
2.0
160
3.0
197
4.4

0.100
53
1.9
70
1.9
80
2.9
92
2.6
114
2.1
156
3.3
195
4.6

0.125
51
1.9
68
1.9
78
3.0
88
2.7
110
2.2
155
3.3
194
4.7

CFM/Static Pressure in inches of WG
0.250 0.375 0.500 0.625 0.750 1.000
40
29
2.6
3.5
57
49
39
2.4
3.1
3.6
68
61
54
44
30
3.2
3.6
4.3
5.5
5.6
75
59
45
30
3.0
3.6
4.1
4.9
97
95
94
91
85
50
2.4
2.7
2.8
3.6
4.4
5.4
154
152
149
147
138
92
3.7
4.3
4.5
5.0
5.3
5.8
191
187
184
181
166
128
5.1
5.6
5.8
6.0
6.3
6.6
5 UL Listed for use above tubs.
6 Available with 277 volt motor.

3 Available with CRD - Ceiling Radiation Damper
4 Available with 50 Hz motors (See CAPS for performance)

Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.

SP

®

STANDARD CEILING FAN
Dimensional Data
Model
50

A

B

71/ 2 71/ 2

C

D

E

F

Grille

Wt.

35/ 8

3

1 5/ 8

1/ 2

91/4 x 9

5

For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

B

C

A
D
E

C
F

Performance Data
Model

RPM

SP-C50

1680

AMPS Watts
0.80

46

CFM/Static Pressure in inches of WG
0.00 0.100 0.125
0.250 0.375 0.500
CFM
52
49
48
46
43
37
Sones 2.9
3.6
3.6
3.9
4.2
4.8

0.625
29
6.3

Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.

17

CSP

®

PREMIUM INLINE FAN
Dimensional Data

A
B

Model

A

B

C

D

E

F

G

Wt.

110, 125, 190

131/4

105/8

101/2

8

6

12

91/4

16

200,250, 290, 390

14

117/8

111/4

8

8

127/8

10

23

410, 510

18

143/8

141/2

8

8

167/8

131/4

36

700

235/8

115/8

115/8

191/2

8

225/8

101/2

34

141/2

8

167/8

131/4

36

710, 780

18

143/8

900, 1050,
1410, 1550

233/4

143/8

141/2 183/4

8

225/8

131/4

59

1750, 2150

35

143/4

143/4

28

6

323/4

13

68

3600

451/2

161/2

161/2

40

11

431/4

145/8

122

10

Inlet and outlet connections widths are 1 inch - Mounting bracket width is 1½ inch
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

A
E

G

D
C
F et
In l

F

C

G
E
B

D
A

Performance Data
Model

RPM

AMPS

Watts

4,6

CSP-A110

950

0.62

51

1100

0.63

55

CSP-A190

1400

1.10

100

CSP-A200

900

0.43

48

CSP-A250

1000

0.79

83

CSP-A290

1050

0.71

80

CSP-A390

1350

1.33

144

CSP-A410

1000

1.87

139

CSP-A510

1070

3.11

217

CSP-A700

1100

3.20

350

CSP-A710

1080

4.40

325

CSP-A780

1600

3.77

405

CSP-A900

950

4.87

328

CSP-A1050

1095

6.65

455

CSP-A1410

1450

7.80

822

CSP-A1550

1610

8.32

830

CSP-A1750

1130

6.60

550

CSP-A2150

1100

7.80

735

CSP-A3600

1100

7.10

1330

6

CSP-A125
4,6

4

4

4

4

CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones

0.000
124
1.1
138
1.4
215
2.3
254
0.8
266
1.3
318
1.6
412
2.8
447
2.2
545
3.1
766
2.6
737
3.2
813
3.8
908
1.9
1182
3.5
1584
4.2
1672
5.8
1842
6.4
2249
6.0
3778
6.4

4 Units available with 50 Hz motors (See CAPS for performance)

0.100
112
1.1
126
1.4
202
2.0
230
0.7
246
1.5
299
1.7
400
2.7
411
2.1
514
2.9
755
2.5
698
3.3
783
3.6
852
2.0
1110
3.2
1543
4.0
1617
5.4
1767
6.0
2175
5.8
3653
6.1

CFM/Static Pressure in inches of WG
0.125
0.250
0.375
0.500
110
102
77
1.1
1.3
1.3
124
113
91
1.3
1.4
1.7
198
180
159
121
2.2
2.7
2.9
3.0
225
203
177
145
0.8
1.3
1.5
1.9
241
221
205
187
1.5
2.3
3.3
3.4
292
265
248
229
1.8
2.6
3.3
4.0
397
382
363
339
2.8
3.2
3.7
4.7
403
364
316
217
2.2
2.5
2.7
2.7
506
464
405
324
2.8
2.8
2.7
3.1
752
739
726
702
2.4
2.4
2.5
2.6
688
635
566
474
3.2
3.3
2.7
2.5
776
741
707
671
3.6
3.5
3.4
3.5
840
782
714
631
2.0
2.3
2.6
2.9
1093
1013
922
832
3.1
3.1
3.4
3.4
1533
1483
1439
1395
4.0
4.1
4.2
4.3
1604
1542
1484
1427
5.3
5.4
5.4
5.1
1749
1619
1463
1283
6.0
5.5
5.3
4.7
2156
2044
1900
1701
5.8
5.2
5.0
4.6
3622
3460
3280
3091
6.1
5.7
5.4
5.1

0.625

0.750

109
2.2
165
3.2
201
3.7
324
5.5

70
2.1
132
3.0
144
3.4
309
6.5

678
2.7
334
2.7
637
3.6

635
3.0

418
4.9

603
3.8

527
4.3

1293
4.6
1306
5.2
771
3.8
1114
3.4
2551
4.7

1181
5.0
1171
5.8

743
3.4
1345
4.5
1367
5.1
1032
4.1
1424
3.8
2844
4.9

1.000

1750
4.3

6 Available with 277 volt motor.

Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown
is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) from the test inlet duct in a hemispherical free field
calculated per AMCA Standard 301. Values are for installation type D: Ducted inlet fan sone levels. Ratings do not include the effects of duct end correction. Ratings are based on 10 ft.
of insulated duct. The AMCA Certified Ratings Seal applies to air performance only.

18

CSP

®

DELUXE INLINE FAN
Dimensional Data
Model

A

B

D
dia.

B

C

D

E

F

G

Wt.

Inlet
F xG

110, 150, 200 137/ 8 111/ 2 715/ 16 6 11/ 4 101/ 4 31/ 4 101/ 4

C
E

Outlet connection width is 1 inch - Mounting bracket width is 1½ inch
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

A

B

Performance Data
CFM/Static Pressure in inches of WG
Model

RPM

AMPS

Watts

4,6

CSP-B110

950

1.14

80

1050

1.70

129

1100

2.20

173

4,6

CSP-B150
4,6

CSP-B200

0.000

0.100

0.125

0.250

0.375

0.500

0.625

0.750

103
2.0
151
2.5
186
3.4

100
2.0
149
2.7
184
3.6

99
2.1
149
2.7
183
3.7

98
2.3
148
2.9
182
4.0

97
2.6
147
3.1
180
4.1

96
2.7
145
3.4
178
4.1

93
3.1
142
3.6
175
4.3

86
3.3
134
3.9
169
4.5

CFM
Sones
CFM
Sones
CFM
Sones

4 Units available with 50 Hz motors (See CAPS for performance)

6 Available with 277 volt motor.

Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown
is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) from the test inlet duct in a hemispherical free field
calculated per AMCA Standard 301. Values are for installation type D: Ducted inlet fan sone levels. Ratings do not include the effects of duct end correction. Ratings are based on 10 ft.
of insulated duct. The AMCA Certified Ratings Seal applies to air performance only.

Typical
Typical Specifications
Specifications

Model SP-C50
Ceiling mounted exhaust fans shall be of the centrifugal direct drive
type. The fan housing shall be constructed of steel. The plastic
duct collar shall be a tapered sleeve for ease of connection to
3 and 4 inch round ductwork and shall include a backdraft damper.
The grille shall be constructed of non-yellowing high impact
polystyrene and attached to the housing with torsion springs.
The wheels shall be constructed of high strength polymer. The
access for wiring shall be external. The motor disconnect shall
be internal and of the plug in type. All fans shall bear the AMCA
Certified Ratings Seal for sound and air performance. Model
SP-C50 shall be UL Listed. Fans shall be Model SP-C50 as supplied
by Greenheck Fan Corporation, Schofield, Wisconsin.
Models SP-B50, B70, B80, B90, B110, B150, and B200
Ceiling mounted exhaust fans shall be of the centrifugal direct
drive type. The fan housing shall be constructed of steel. The
steel duct collar shall be 4 inch in diameter on the B50, B70, and
B80 and 6 inch in diameter on the B90, B150, and B200 to accept
4 inch and 6 inch round ductwork and shall include a backdraft
damper. The designer grille shall be constructed of non-yellowing
high impact polystyrene and attached to the housing with hidden
attachment screws. The access for wiring shall be external. The
motor disconnect shall be internal and of the plug in type.
The motor shall be mounted on vibration isolators. The fan wheel
shall be of the forward curved centrifugal type, constructed of
calcium carbonate filled polypropylene and dynamically balanced.
All fans shall bear the AMCA Certified Ratings Seal for sound
and air performance and shall be UL/cUL Listed. Ceiling or wall
mount fans shall be Model SP-B50, B70, B80, B90, B110, B150 or
B200 as manufactured by Greenheck Fan Corporation, Schofield,
Wisconsin.
Models SP-A50 thru A1550
Ceiling mounted exhaust fans shall be of the centrifugal direct
drive type. The fan housing shall be constructed of heavy gauge
galvanized steel. The housing interior shall be lined with 1/2 inch
acoustical insulation. The outlet duct collar shall include an aluminum
backdraft damper on all SP-A sizes and shall be spring loaded on
size SP-A110 and larger. Outlet shall be adaptable for horizontal
or vertical discharge. The designer grille for sizes SP-A50 through
SP-A390 shall be constructed of high impact polystyrene and for
sizes SP-A410 through SP-A1550, the grille shall be constructed of
aluminum. Grilles shall be non-yellowing.

The access for wiring shall be external. The motor disconnect shall
be internal and of the plug in type. The motor shall be mounted on
vibration isolators. The fan wheel(s) shall be of the forward curved
centrifugal type and dynamically balanced. All fans shall bear the
AMCA Certified Ratings Seal for sound and air performance and
shall be UL/cUL Listed. Ceiling or wall mount fans shall be Model
SP as manufactured by Greenheck Fan Corporation, Schofield,
Wisconsin.
Models CSP-B110, B150, and B200
Duct mounted exhaust, supply or return air fans shall be of the
centrifugal direct drive type. The fan housing shall be constructed
of steel. The steel duct collar shall be 6 inch in diameter to accept
6 inch round ductwork and shall include a backdraft damper. The
access for wiring shall be external. The motor disconnect shall be
internal and of the plug in type.
The motor shall mounted on vibration isolators. The fan Wheel shall
be of the forward curved centrifugal type, constructed of calcium
carbonate filled polypropylene and dynamically balanced. All fans
shall bear the AMCA Certified Ratings Seal for air performance and
shall be UL/cUL Listed. Ceiling or wall mount fans shall be Model
CSP-B110, B150 or B200 as manufactured by Greenheck Fan
Corporation, Schofield, Wisconsin.
Models CSP-A110 thru A3600
Duct mounted exhaust, supply or return air fans shall be of the
centrifugal direct drive type. The fan housing shall be constructed
of heavy gauge galvanized steel. The housing interior shall be lined
with 1/2 inch acoustical insulation. The outlet duct collar shall
include an aluminum backdraft damper and shall be adaptable
for horizontal or vertical discharge. The access for wiring shall be
external. The motor disconnect shall be internal and of the plug in
type.
The motor shall be mounted on vibration isolators. The fan wheel(s)
shall be of the forward curved centrifugal type and dynamically
balanced. All fans shall bear the AMCA Certified Ratings Seal for
air performance and shall be UL/cUL Listed. Ceiling or wall mount
fans shall be Model CSP as manufactured by Greenheck Fan
Corporation, Schofield, Wisconsin.

19

Ceiling Fan Solutions
Ceiling Fans

Ceiling Fans
w/ Light

Ceiling Fans
w/ CRD

Ceiling Fans
w/ Light & CRD

SP-A110

SP-A110

SP-A390

SP-A125

SP-A50

SP-A70

SP-A90

SP-A90

SP-B50

SP-B90

SP-B200

SP-B80

Our Warranty
Greenheck Fan Corporation warrants its SP/CSP products to be free of any defect in
material or workmanship for a period of three (3) years from the date of purchase. In the
event of such a defect during the warranty period, Greenheck Fan Corporation agrees, at
its option, to either repair or replace the defective product free of charge. This warranty
runs to the original purchaser of such SP/CSP products for a period of three (3) years from
the date of purchase. Any product repaired or replaced under this warranty will, itself,
be warranted only for the remainder of the warranty period of the original product being
repaired or replaced. All light bulbs are excluded under this limited warranty. Greenheck
Fan Corporation is not responsible for any removal, installation, or transportation cost. For
full SP/CSP warranty information visit www.greenheck.com.
As a result of our commitment to continuous improvement, Greenheck reserves the right to
change specifications without notice.

P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com

Catalog SP CSP Rev 5 November 2006 SP
Copyright © 2006 Greenheck Fan Corp.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Modify Date                     : 2006:12:02 11:07:26-06:00
Creator Tool                    : Adobe InDesign CS2 (4.0.4)
Create Date                     : 2006:12:02 11:07:26-06:00
Format                          : application/pdf
Creator                         : dt_1
Title                           : 44754.indd
Document ID                     : uuid:e42c0fe0-8227-11db-8762-000d93c9683e
Instance ID                     : uuid:e42c1436-8227-11db-8762-000d93c9683e
Page Count                      : 20
Author                          : dt_1
EXIF Metadata provided by EXIF.tools

Navigation menu