Guidance Marine RANGEGUARD RangeGuard Wide Beam 20-0183-1 User Manual 94 0447 4 A Rangeguard Operators Guide

Guidance Navigation Ltd. RangeGuard Wide Beam 20-0183-1 94 0447 4 A Rangeguard Operators Guide

User manual

Download: Guidance Marine RANGEGUARD RangeGuard Wide Beam 20-0183-1 User Manual 94 0447 4 A Rangeguard Operators Guide
Mirror Download [FCC.gov]Guidance Marine RANGEGUARD RangeGuard Wide Beam 20-0183-1 User Manual 94 0447 4 A Rangeguard Operators Guide
Document ID2643002
Application IDLIFv1z3P+g38tMjLOR79uQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize277.03kB (3462848 bits)
Date Submitted2015-06-10 00:00:00
Date Available2015-06-10 00:00:00
Creation Date2015-04-21 09:50:42
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2015-04-21 09:50:45
Document Title94-0447-4-A Rangeguard Operators Guide
Document CreatorAdobe InDesign CC 2014 (Macintosh)
Document Author: Guidance Marine Ltd

Rangeguard Operator’s Guide
Issue Date: 21/04/2015
Document No: 94-0447-4-A
Serial No:
Sensor Software Version:
Software Version:
Guidance Marine Ltd,
4 Dominus Way
Meridian Business Park
Leicester
LE19 1RP
UK
Date of Shipment from UK:
Tel: +44 116 229 2600
Tel (Customer Services): +44 116 229 2665
Fax: +44 116 229 2604
Email: customerservices@guidance.eu.com
Web: www.guidance.eu.com
www.marine.direct
Copyright © 2015 Guidance Marine Limited. All Rights Reserved.
Copyright in the whole and every part of this document belongs to Guidance Marine Limited (the
“Owner”) and may not be used, sold, transferred, copied or reproduced in whole or in part in any
manner or form or in or on any media to any person other than in accordance with the terms of
the Owner’s Agreement or otherwise without the prior written consent of the Owner.”Windows”
is a trademark of Microsoft Corporation. All other brand or product names are trademarks or
registered trademarks of their respective companies or organisations.
0191
Document History
Document Number
Changes
Issue Date
94-0447-4-A
First Release of Rangeguard Operator’s Guide
21/04/2015
Table of Contents
Introduction
System Overview....................................................................................................... 6
Getting Started
Start Up and Shut Down........................................................................................... 8
Start Up.............................................................................................................................................. 8
Shut Down.......................................................................................................................................... 8
Screen Layout........................................................................................................... 9
Table View ........................................................................................................................................ 10
Display Options....................................................................................................... 12
Selecting/Deselecting Sensors............................................................................... 13
Measurement Algorithms
Selection of Measurement Algorithm...................................................................... 15
Setting the Range Limits......................................................................................... 16
Closest Algorithm.................................................................................................... 17
Manual Threshold Algorithm................................................................................... 18
Max Peak Algorithm................................................................................................ 19
Peak Lock Algorithm............................................................................................... 20
Appendices
System Specifications............................................................................................. 22
FCC Warning Statement......................................................................................... 23
Index........................................................................................................................ 24
Introduction
Welcome to the RangeGuard Operator’s Guide. It explains how to use the RangeGuard
system once it has been fully installed.
For instructions on how to install RangeGuard onto a vessel, refer to 94-0448-4
RangeGuard Installer’s Guide.
The System Overview on page 6 describes the different components of the system and
how they work together.
The Getting Started section on page 8 explains how to get the system up and running
and how to shut it down again. It also details what you will see on the RangeGuard Display
screen when the system is running, and how to interpret the information.
The Measurement Algorithms section on page 14 describes the different ways that
RangeGuard can measure the distance to an object.
Further useful information is included in the Appendices section on page 21.
System Overview
The RangeGuard system provides object detection and distance measurements using
continuous wave radar sensors. These operate on a licence-exempt Short Range
Device basis at 24.15GHz. The system comprises a control box, up to four sensors and
a graphical user interface which can be accessed from any device connected to the
same network. The sensors are typically positioned around the outside of a vessel and
connected to the control box via standard Cat5e Ethernet cable up to a maximum length of
100m; longer cables can be made using cable with additional cores.
RangeGuard Display - the user interface - is run from a web browser. It is recommended
that either the user interface supplied by Guidance Marine or else Google Chrome are
used. Other browsers will work but without guarantee. Once the control box has been
connected to the network, type its IP address (default 192.168.2.231) into the web browser
address bar and the user interface will appear in Bird’s Eye View.
The sensors have a fixed elevation beam width of 11° (+/-5.5°) and two options of azimuth
beam: 11° (Narrow Beam) and 90° (Wide Beam). Each sensor measures the range to the
nearest obstacle by default or to a selected obstacle if preferred.
Getting Started
This section describes RangeGuard Display and basic use of the system.
It contains the following pages:
•
•
•
Start Up and Shut Down (Page 8)
Screen Layout (Page 9)
Display Options (Page 12)
Start Up and Shut Down
Start Up
To Open RangeGuard Display
1. Ensure that the control box is powered on.
2. Double-click on the RangeGuard icon.
(Or run the RangeGuard Display application from:
Start > All Programs > Guidance RangeGuard > RangeGuard Display).
3. The display will appear in full screen mode, with the Bird’s Eye View open.
Shut Down
To Close RangeGuard Display
Click on the X button in the top right corner of the screen.
Bird’s Eye View
Side Bar
Screen Layout
The RangeGuard Display presents positional information in one of three main formats,
Bird’s Eye View, Table View and Single Sensor View.
Bird’s Eye View (BEV)
The BEV depicts the operational area of the RangeGuard system from above. By default,
the BEV is centred on an image of the vessel and around this it shows a radar beam, range
measurement and received signal level for each sensor that has detected an object.
Bird’s Eye View focussing on one sensor
The contents of the BEV can be enlarged or reduced by means of the Zoom In and Zoom
Out buttons in the bottom right of the screen. Six zoom levels are available and the current
level is indicated by the yellow bars between the buttons:
Bird’s Eye View without a sensor in focus
Clicking on any one of the radar beam sectors causes a shift in the BEV so that the object
detected by that beam is now at or close to the centre. The colour of the beam changes
to reflect the range of the object (red, amber or green in accordance with configured alarm
limits). The colours of the other beams also change to reflect the ranges of the objects that
they have detected.
The position represented by the mouse cursor on the BEV, taking into account the zoom
level, is displayed above the zoom buttons, e.g. Mouse at 117°, 68.10 m from vessel
centre. These numbers are updated as the cursor is moved across the screen.
In order to switch to the BEV from one of the other views, click on the
Bird’s Eye View button in the top right of the display screen:
Screen Layout (Continued)
Table View
By default, this displays the positional data for all of the currently chosen sensors, in the
form of a table. For each sensor this comprises:
: The measured distance to the object detected by the sensor. The background
• Range
of this field is coloured according to the range value:
Red for ranges below configured red alarm limit
Amber for other ranges below configured amber alarm limit
White for longer ranges or if no measurement is made
Strength : Represented by filled segments of a bar chart and – if the cursor is
• Signal
moved over the chart - numerically in the tooltip.
This is calculated from the most recent range measurements and marked as
• Speed:
“Closing Speed” if the sensor is approaching the object and “Separating Speed” if
moving away.
to Contact: How long it would take for the vessel to make contact with the
• Time
detected object, based on the currently-displayed closing speed. Displayed as a
number of seconds or as “> 1 min”. In the case of a separating speed, the field
contains “---“.
Each row in the table contains a Profile button, which replaces the positional values for a
sensor with a Profile plot:
This represents the signal returned at each range – a large vertical peak means that an
object exists at the range shown by the horizontal axis.
The buttons along the top of the graph allow you to choose the way in which the system
interprets the received signals.
10
Screen Layout (Continued)
In order to switch to Table View from one of the other views,
click on the Table View button in the top right of the display screen:
Alternatively, by clicking on the Expand Spectrum button in the bottom right corner the
screen is split between positional data and the profile plot:
Single Sensor View
This is essentially a magnified form of the data in a single row of the Table View, with the
addition of downward-pointing chevrons to indicate a closing speed or upward-pointing
chevrons to indicate a separating speed. At very low speeds, only the top chevron is
coloured (red for closing and green for separating). At higher speeds, the second and third
chevrons are also coloured.
Single Sensor View can show the positional data in extra-large numerals:
Click on the Collapse Spectrum button to maximise the positional data again.
In order to switch to Single Sensor View:
Either
Double-click on one of the radar beams on the Bird’s Eye View
Or
Double-click on one of the rows in Table View.
11
Display Options
To provide clear visibility during daytime operation and minimal glare during night shifts, the
RangeGuard Display offers two display modes: Day View and Night View. In either mode
the brightness can be further modified by brightness adjustment buttons.
To change the day/night view and adjust brightness:
If in day mode, click on the Toggle Night Mode button:
If in night mode, click on the Toggle Day Mode button:
Click on the Decrease Brightness button to dim the screen:
Click on the Increase Brightness button to brighten the screen
Hotkey Buttons
12
Selecting/Deselecting Sensors
A RangeGuard system can be run with up to four sensors. The overall sensor count and
characteristics of each sensor are configured at installation time in the password-protected
RangeGuard Control Panel (see 94-0448-4 RangeGuard Installer’s Guide for details).
However, each sensor can be selected/deselected on the fly,
using the Choose Sensors button:
Click on this button to obtain a menu containing the label of each sensor and a checkbox:
Only data from currently-selected sensors is shown on the Bird’s Eye View and Table View.
13
Measurement Algorithms
This section describes the different ways that RangeGuard can make measurements.
It contains the following pages:
It contains the following pages:
•
•
•
•
•
•
Selection of Measurement Algorithm (Page 15)
Setting the Range Limits (Page 16)
Closest Algorithm (Page 17)
Manual Threshold Algorithm (Page 18)
Max Peak Algorithm (Page 19)
Peak Lock Algorithm (Page 20)
14
Selection of Measurement Algorithm
There is a measurement algorithm setting for each sensor in the system. It is selected via
the buttons above the sensor’s profile plot in Table View or Single Sensor View:
The algorithms use different methods of extracting a range measurement from the reflected
signal received by the sensor.
Each algorithm potentially gives a different range value in any given situation, so it is
important to choose one that is appropriate for your needs.
You may also want to disregard reflections from the shortest or longest ranges; see Setting
the Range Limits on page 16.
15
Setting the Range Limits
By default, when calculating the range of an object, the system takes into account all
reflected signals that it receives. However, it is possible to mask out reflections from the
shortest and/or longest ranges, for example to ignore an overhanging feature of the vessel’s
own structure.
To set the Range Limits for a sensor:
1.
Go into Table View and open the Profile for the relevant sensor, or else enter Single
Sensor View and expand the Profile.
2.
Click and drag one or both of the green Range Limit sliders:
The beam for this sensor on the Bird’s Eye View is sized according to these limits:
Range Limit Sliders
3.
Leave the left-hand slider at the range below which you want all reflections to be 		
ignored.
4.
Leave the right-hand slider at the range above which you want all reflections to be
ignored.
Alternatively, double-click either of the sliders and type a numerical value into the entry box:
16
Closest Algorithm
When the Closest algorithm is selected, RangeGuard bases its range measurement on the
shortest range peak in the reflected signal, within the Range Limits and above the Signal
Threshold. For this algorithm the Signal Threshold is fixed at 20dB above the nominal noise
floor.
The measured range is indicated on the Profile Plot by a vertical red line:
Measured Range (approx 100m)
17
Manual Threshold Algorithm
When this algorithm is selected, the Signal Threshold is adjustable, instead of being fixed at
20dB. Move the red slider up or down the dB axis to a suitable threshold level:
Signal Threshold
Measured Range
Note that the Manual Threshold algorithm measures the lowest range at which the signal
breaks through the threshold, as distinct from the Closest algorithm which uses the lowestrange peak.
Alternatively, double-click the red slider and type a numerical value into the entry box:
18
Max Peak Algorithm
With this algorithm no Signal Threshold is applied and the strongest reflected signal within
the Range Limits is used for the range measurement, rather than the closest:
Measured Range
19
Peak Lock Algorithm
With this algorithm, you can manually select a peak within the Range Limits that is not
necessarily the closest or highest. The system then locks onto it and reports its range.
In order to select a peak, move the red slider along the Range axis:
Measured Range
Peak Picker
20
Appendices
This section contains the following appendices:
•
•
•
System Specifications (Page 22)
FCC Warning Statement (Page 23)
Index (Page 23)
21
System Specifications
Environmental
Sensor
Transceiver Type
Frequency Modulated Continuous Wave (FMCW)
Ambient Temperature Range
-25 to +55°C
Frequency Band
24.05GHz – 24.25GHz (Licence Exempt Short Range Device)
Atmospheric Conditions
Operates in fog, heavy rain, snow and ice conditions
Maximum Power Output
<100mW EIRP (EN 300 440 Compliant)
300m
Water and Dust Protection
(Sensor)
IP67 certified
Maximum Operating Range
Minimum Operating Range
1m
Standards Compliance
Range Accuracy*
±2cm + 0.1% of Range
EN 300 440-1 and 2, EN 60945 & EN301 843-1 (EMC) EN
60936:2002, Annex D, ITU-R
Angular Accuracy*
N/A
Recommendation RM. 1177
1000mm (worst case) @ 0.3° deflection
European Directive 2004/108/EC
Azimuth Beam width
90° or 11° (10dB Width)
EN60945
IP66 rated
Target Detection
Automatic or by manual selection
RF Immunity
Resistant to S and X band Radar when installed as recommended
Vertical Beam Height
+/- 5.5°
Sensor Mechanical
Vessel Interface
Height
23 cm
Sensor Power
85 to 264v AC 45-65 Hz 5A, Max 100W
Width
17 cm
Sensor Control
Analogue and Digital control on CAT 5e SCTP
Depth
13 cm
Sensor DP Feed
N/A
Weight
4 kg
Supported DP Systems
N/A
Max Cable run per sensor
Up to 100m (CAT5e SCTP cable, Min AWG 24)
Sensor Control
Sensor Control capable of displaying 4 sensors simultaneously
Sensor Control Protocol
Ethernet
22
FCC Warning Statement
device complies with Part 15 of the FCC Rules.
• This
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
equipment complies with FCC radiation exposure limits set forth for an
• This
uncontrolled environment. End users must follow the specific operating instructions
for satisfying RF exposure compliance. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
or modifications not expressly approved by the party responsible for
• Changes
compliance could void the user’s authority to operate the equipment.
23
Index
FCC Warning Statement 23
Hotkey Buttons 12
Overview
System 6
Shut Down 8
Side Bar 8
Start Up 8
System Overview 6
24


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c011 79.156289, 2014/03/31-23:39:12
Create Date                     : 2015:04:21 09:50:42+01:00
Modify Date                     : 2015:04:21 09:50:45+01:00
Metadata Date                   : 2015:04:21 09:50:45+01:00
Creator Tool                    : Adobe InDesign CC 2014 (Macintosh)
Instance ID                     : uuid:31cae3c1-7a97-3f49-8d08-25adbed504cb
Original Document ID            : adobe:docid:indd:d69738c1-3949-11de-bedd-942b62bc52e5
Document ID                     : xmp.id:374e94a2-f591-4035-a4db-10ba8635e1f5
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:8e0f31a5-d67a-4431-91af-c245de367427
Derived From Document ID        : xmp.did:43b2c0ef-f42d-4b20-afca-792323293734
Derived From Original Document ID: adobe:docid:indd:d69738c1-3949-11de-bedd-942b62bc52e5
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Macintosh)
History Changed                 : /
History When                    : 2015:04:21 09:50:42+01:00
Format                          : application/pdf
Title                           : 94-0447-4-A Rangeguard Operators Guide
Rights                          : Copyright © 2015 Guidance Marine Limited. All Rights Reserved..Copyright in the whole and every part of this document belongs to Guidance Marine Limited (the “Owner”) and may not be used, sold, transferred, copied or reproduced.in whole or in part in any manner or form or in or on any media to any person other.than in accordance with the terms of the Owner’s Agreement or otherwise without.the prior written consent of the Owner..Windows is a trademark of Microsoft Corporation..All other brand or product names are trademarks or registered trademarks of their.respective companies or organisations
Creator                         : Guidance Marine Ltd
Date Created                    : 2008:04:29
Marked                          : True
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 25
Author                          : Guidance Marine Ltd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VYMRANGEGUARD

Navigation menu